Home
Johnson Controls S1-CD065T01 User's Manual
Contents
1. e Moving the knob toward MORE DRY will increase the amount of time the dehumidifier runs making conditions dryer e Moving the knob toward LESS DRY reduces the amount of time the dehumidifier runs allowing for higher humidity levels e After initial installation the dehumidifier may run continuously for several days while the dehumidifier works to dry the home and stabilize indoor air conditions e Allow 24 hours for restabilization after changing the dryness level MAINTENANCE AIR FILTER The air filter in the dehumidifier should be cleaned or replaced once per year A clean filter allows the dehumidifier to run at full capacity and prevents damage to the dehumidifier To remove the filter unplug or disconnect power to the dehumidifier Remove the filter by removing the filter access door on the side of the unit The filter can be cleaned by flushing with warm water and a detergent solution Allow the filter to dry before reinstalling in the dehumidifier Reinsert the cleaned or new filter replace the filter access door and reconnect power turn on the dehumidifier A replacement filter S1 4904 is available from your installing contractor or from most HVAC contractors in your area DRAIN The drain and drain hose should be checked and cleaned of debris annually LIMITED WARRANTY UPG warrants this product to be free from defects in factory workmanship and material under normal use and service and will at its option re
2. installation or servicing Damages resulting from accident abuse fire flood alteration or acts of God tampering altering defacing or removing the product serial number will serve to void this warranty Damages resulting from use of the product in a corrosive atmosphere 1 2 3 4 5 Damages resulting from inadequacy or interruption of electrical service or fuel supply improper voltage conditions blown fuses or other like damages 6 Cleaning or replacement of filters 7 Damages resulting from operation with inadequate supply of air or water 8 Damages resulting from use of components or accessories not approved by UPG vent dampers etc 9 Increase in fuel or electric cost 10 Disposable filter which will have to be replaced from time to time depending on the amount of use THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SOME STATES DO NOT ALLOW THE DISCLAIMER OF IMPLIED WARRANTY SO THAT THE ABOVE DISCLAIMER MAY NOT APPLY TO YOU SOME STATES ALLOW ONLY A PARTIAL LIMITATION ON IMPLIED WARRANTIES TO LIMIT THE DURATION OF IMPLIED WARRANTIES TO THE DURATION OF THE EXPRESS WARRANTY IN SUCH STATES THE DURATION OF IMPLIED WARRANTIES IS HEREBY EXPRESSLY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY ON THE FACE HEREOF IN NO EVENT WHETHER AS A RESULT OF BREACH OF WARRANTY OR CONTRACT TORT INCLUDING NEGLIGENCE STRI
3. CT LIABILITY OR OTHERWISE SHALL UPG BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF USE OF THE EQUIPMENT OR ASSOCIATED EQUIPMENT LOST REVENUES OR PROFITS COST OF SUBSTITUTE EQUIPMENT OR COST OF FUEL OR ELECTRICITY THE ABOVE LIMITATIONS SHALL INURE TO THE BENEFIT OF UPG S SUPPLIERS AND SUBCONTRACTORS THE ABOVE LIMITATION ON CONSEQUENTIAL DAMAGES SHALL NOT APPLY TO INJURIES TO PERSON S IN THE CASE OF CONSUMER GOODS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OR FOR STRICT LIABILITY IN TORT SO THAT THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU UPG DOES NOT ASSUME OR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR UPG ANY OTHER LIABILITY FOR THE SALE OF THIS PRODUCT THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE For Owner s Information PRODUCT MODEL NO INSTALLATION DATE UNIT SERIAL NO _ INSTALLING DEALER Subject to change without notice Printed in U S A Copyright by York International Corp 2010 All rights reserved Johnson Controls Form 665510 UUM A 1210 Unita ry Products 10009028 B2205175A 12 10 5005 York Drive Norman OK 73069
4. Johnson Controls 1 CD065T01 Central Dehumidifier A Unitary Products Owner s Manual FRONT VIEW BACK VIEW with alternate outlet location on top with alternate outlet location on back On Off Switch Dehumidistat Alternate Outlet Location Wire Access Door Filter Access Door ram FAULT POWER Inlet Drain Power Cord Status LEDs 4 CAUTION 1 Do not use solvents or cleaners on or near the circuit board 2 Unplug the dehumidifier before servicing Sudden operation may cause personal injury or property damage PRINCIPLE OF OPERATION Your Central Dehumidifier installs as part of your home s central heating and cooling system removing excess moisture and reducing the damage that mold and mildew can have on the sustainability of your home and the health of your family The dehumidistat constantly monitors the relative humidity of the air in your home and controls it to the level you set putting you in control of your comfort OPERATING INSTRUCTIONS Operating your Central Dehumidifier is as easy as 1 2 3 1 Turn the ON OFF switch to ON FIGURE 1 Dehumidistat Setpoints 2 Use the knob on the dehumidistat to set the desired dryness level e Start at 2 1 2 as the initial setpoint for economy property protection and upper end of comfort range See Figure 1 for knob setpoint 3 Change the dryness level up or down as desired for comfort or economy This will vary depending on location and conditions
5. pair or replace any parts that prove to have such defects according to the terms outlined on this warranty This warranty covers only the equipment described by the Product Model Number and Serial Number on the unit and associated receipts from the equipment installation In the absence of an installation receipt the warranty period will begin upon product shipment from UPG This warranty extends only to the original consumer purchaser and is non transferable For this warranty to apply the product must be installed according to UPG recommendations and specifications and in accordance with all local state and national codes and the product must not be removed from its place of original installation The warranty period for repair or replacement parts provided hereunder shall not exceed beyond the warranty period stated below PREMIUM CENTRAL AND CENTRAL VENTILATING DEHUMIDIFIERS PARTS UPG strongly recommends regular periodic preventative maintenance on this equipment The person most familiar with the equipment in your HVAC system is a UPG dealer The UPG dealer can ensure your maintenance program meets the conditions of the UPG Warranty maximize the efficiency of the equipment and service your unit within the mandated guidelines This warranty applies only to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any Shipping labor or material charges Damages resulting from transportation
Download Pdf Manuals
Related Search
Related Contents
Quick Start (English) Industrial Line USER'S GUIDE About the Software on your Sony Notebook Computer CLI User Guide - Juniper Networks Portugues/Produtos/FBs/02 UCPs/Caracteristicas Tecnicas Philips FlexAdapt DLC2407GRN Sony Radio ICF-SW7600 User's Manual Copyright © All rights reserved.
Failed to retrieve file