Johnson Controls AS-CVTPROx00-1 User's Manual

image

Contents

1. ASSA Pll 4 Pin N2 Plug A fi Connect these Unplugged amp fer Ap A4 components from the VMA to scan the N2 Bus via the CVTPRO Converter To To Next N2 REF N2 Next N2 N2 _ N2 N2 Device N2 N2 REF Device CVTVMA Figure 7 CVTPRO N2 Connection to a VMA with a Removable N2 Plug 4 AS CVTPROx00 1 Zone Bus N2 Bus Interface Converter Installation Instructions Compatibility Table 4 lists compatible tools Operating Systems and controllers used over the Zone Bus and N2 Bus with the CVTPRO converter Table 4 Compatibility Chart Compatible controllers include the Air Handling Unit AHU Unitary Controller UNT Variable Air Volume Controller VAV Network Dialer Module NDM and VMA Tool Bus Operating System Compatible Controller HVAC PRO Software part of N2 Bus Windows 98 SE Windows NT AHU1xx M Tool Release 5 0 or later Windows 2000PE OS UNT1xx Zone Bus Windows 98 SE Windows 2000PE UNT11xx os VAV1xx VMA14x0 Zone Bus Windows NT VMA14x0 VBT1400 Zone Bus Palm Personal Digital Assistant PDA VMA14x0 with OS Version 3 5 or later VBT1200 Zone Bus Palm PDA with OS Version 2 x or later VMA12x0 GX 9100 Software N2 Bus Windows 98 SE Windows NT DT 9100 Configuration Tool part of Windows 2000PE OS DX 9100 M Tool Release 5 0 or later XT9100 XP91xx XTM 905 XPx xxx XTM Configu
2. 2003 Johnson Controls Inc Part No 24 9544 0 Rev C Connector for Palm V Adapter Palm Ill or Palm VII Red LED Power Battery Cover Figure 2 CVTPRO Converter Front A CAUTION Risk of Property Damage Do not apply power to the system before checking all wiring connections Short circuited or improperly connected wires may result in permanent damage to the equipment Cable Connectors Figure 3 shows the 6 pin phone plug end of the N2 cable used by the CVTPRO converter for N2 Bus communication For Zone Bus communication always use standard Zone Bus cables AUU N2 Buy MAUN N2 Ref Red N2 White Figure 3 N2 Cable 6 Pin RJ11 Network Phone Plug I in Signal N2 Zone Bus Power GND N2 Ref Zone Bus Signal N2 OnkWNM Figure 4 Zone Bus N2 Bus RJ11 Network Phone Jack Pin Designations 1 www johnsoncontrols com Table 1 Cables Included with the CVTPRO Converter To Connect the CVTPRO Use This Cable Converter To PC via RS232 CVTPRO serial cable 18 inches 457 mm Controller via the Zone B Controller via the N2 Bus us 8 pin RJ45 to 6 pin RJ11 phone cable 6 ft 1 8 m 4 pin N2 socket 3 pin N2 plug to 6 pin RJ11 phone cable 6 ft 1 8 m Note Remove the 4 pin N2 socket from the cable and use the bare wires to connect to N2 screw terminal devices Controller Zone Bus via TE 6x00 6 pin to 6 pin RJ11 phone cable 6 ft 1 8 m TMZ sensor
3. hand e When performing long downloads with the CVTPRO converter use the External Power Adapter instead of batteries Table 5 Typical Battery Life in CVTPRO Converter AAA Battery Manufacturer Battery Life and Model Type Ray O Vac Industrial Plus 4 1 2 hours Duracell CopperTop 5 1 2 hours Eveready Energizer Max 6 1 2 hours using a CVTPRO converter in continuous operation on a fully loaded N2 Bus at room temperature 70 F 21 C AS CVTPROx00 1 Zone Bus N2 Bus Interface Converter Installation Instructions 5 Technical Specifications Product AS CVTPROx00 1 Zone Bus N2 Bus Interface Converter AS CVTPRO100 1 with 120VAC 3VDC External Power Adapter North American version AS CVTPRO200 1 without power adapter European version Power Requirements Zone Bus Controller Supplied Power Stand alone or via Thermostat 24 VAC or VMA applications 15 VDC N2 Bus External Power Adapter 120 VAC to 3 VDC 200 mA Class 2 Transformer Included with CVTPRO Converter in North America only or Battery Power Two type AAA Alkaline not included see Table 5 Agency Listings FCC Part 15 Subpart B Class A CE Mark EN50081 2 Electromagnetic Compatibility EN55011 Class A EN50082 2 Electromagnetic Compatibility EN61000 3 2 and EN61000 3 3 Ambient Operating 0 to 50 C 32 to 122 F 20 80 RH Relative Humidity Conditions 30 C 86 F Maximum Dew Point Ambient Storage 40 to 60 C 40 to 140 F 5 95 RH Conditi
4. JRHNSON CONTRELS Installation Instructions Issue Date April 9 2003 AS CVTPROx00 1 Zone Bus N2 Bus Interface Converter Application The AS CVTPROx00 1 Zone Bus N2 Interface Converter is portable converter designed to provide a communication interface between the room sensors and controllers operating on a Zone Bus or N2 Bus and a Personal Computer PC or specified models of the Palm family of Personal Digital Assistants PDAs See Table 2 for compatible Palm devices See Table 4 for compatible tools Operating Systems OSs and controllers Note The AS CVTPROx00 1 converter can be used in place of the MM CVT101 0 converter module The MM CVT101 0 converter is not compatible with Windows NT Windows 2000 and later versions of Windows OSs Connection Ports The back of the CVTPRO converter Figure 1 has ports for connections to a Personal Computer PC a Palm handheld PDA an External Power Adapter and a Zone Bus N2 Bus RJ11 6 pin network cable phone plug 6 Pin RJ11 Phone Jack Input Jack for for Zone Bus N2 Bus External Power Network Connection Adapter Serial Port for PC or Palm m1xx or m5xx Devices Figure 1 CVTPRO Converter Back The front of the CVTPRO converter Figure 2 shows the mating connector for a Palm IIl Palm V or Palm VII PDA Green and yellow Light Emitting Diodes LEDs display the N2 communication status of the unit relative to the field device The red LED shows power status
5. Table 2 Connections to Palm Devices To Connect the CVTPRO Use In This Sequence Converter To Palm Ill and Palm VII Devices Nothing Palm III Palm VII CVTPRO converter Palm V Device Dock V Pro Adapter Palm V Dock V Pro Adapter CVTPRO converter Palm m100 and m105 Devices Palm HotSync Cable Palm m100 m105 Palm HotSync Cable null Null Modem Adapter modem adapter CVTPRO Serial Cable CVTPRO Serial Cable CUERS Covel Palm m125 m130 and m5xx Belkin Serial Sync Cable Palm m125 m130 m5xx gt Belkin Serial Sync Cable Devices Null Modem Adapter null modem adapter CVTPRO Serial Cable 3 CVTPRO converter CVTPRO Serial Cable 1 The Dock V Pro adapter is available from Solvepoint Corporation at www palmdock com and local retailers 2 Order through Johnson Controls e Purchasing ITAS See Table 3 3 Included with the CVTPRO converter Table 3 CVTPRO Converter and Accessories Product Code Numbers Product Code Number AS CVTPRO100 1 AS CVTPRO200 1 AS CVTPRO 701 AS CVTCBL 700 Dock V Pro adapter F3X1082 03 ME213 P10701U Description Zone Bus N2 Bus Interface Converter with 120VAC 3VDC power adapter North American version Zone Bus N2 Bus Interface Converter without power adapter European version CVTPRO converter without cables or case Replacement set of cables used with the CVTPRO converter Adapter to connect the CVTPRO converter to a Palm V device Belkin Serial Sync Cable for use wi
6. h a removable N2 plug 1 Remove the 3 or 4 pin N2 plug from the controller 2 Plug the 3 pin plug CVTPRO N2 cable into the jack on the controller The Variable Air Volume Modular Assembly VMA has 4 pin jack and other N2 controllers have 3 pin jacks Observe proper polarity N2 is blue N2 is white Ref is red 3 Connect the 6 pin RJ11 phone plug on the opposite end of the CVTPRO N2 cable to the CVTPRO converter Figure 3 Note Figure 7 shows the possible connections with a VMA controller with a removable 4 pin N2 plug To scan a N2 Bus 1 Disconnect the N2 Bus from the N2 master controller 2 Remove the N2 plug with attached N2 wires from the controller 4 pin plug on the VMA and 3 pin plug on other controllers 3 Connect the 3 pin or 4 pin N2 plug that was disconnected from the controller in Step 2 to the 4 pin N2 socket on the CVTPRO converter cable See Figure 7 Observe proper polarity N2 is blue N2 is white Ref is red 4 Connect the 6 pin RJ11 phone plug on the opposite end of the CVTPRO N2 cable to the CVTPRO converter Figure 3 and Figure 5 g VMA Z5 gz 4 Pin Jack _ 2 ase pn Ope Connect these P EA q2 components n I to communicate with the controller f via the CVTPRO CVTPRO N2 Cable Converter 3 Pin N2 Plug Cable to the 6 Pin RJ11 Phone Plug and CVTPRO Converter 4 Pin N2 Socket on the a aaa CVTPRO N2 Cable x
7. me time 2 Unplug the Palm device from the CVTPRO converter when not in use conserves battery power 3 The CVTPRO200 1 European version does not ship with an external power adapter Figure 5 Overview of Possible CVTPRO Converter Connections 3 AS CVTPROx00 1 Zone Bus N2 Bus Interface Converter Installation Instructions Connecting the CVTPRO Converter to a Controller with N2 Screw Terminals To connect the CVTPRO converter to a controller with screw terminals Figure 6 1 Disconnect the three N2 wires from the controller screw terminals and temporarily isolate the individual bare wires with insulating tape 2 Remove the 4 pin N2 socket from the CVTPRO N2 cable to expose the three wires Figure 6 and Figure 7 3 Connect the exposed N2 blue N2 white and Ref red wires from the CVTPRO N2 cable to the controller screw terminals Observe proper polarity 4 Connect the 6 pin RJ11 phone plug on the opposite end of the CVTPRO N2 cable to the CVTPRO converter Figure 3 and Figure 5 CVTPRO N2 Cable 3 Pin N2 Plug Cable to the 6 Pin RJ11 Phone Plug and CVTPRO Converter Ref Red ODDO lt N2 White Remove N2 Blue aaan 4 Pin N2 Wire Directly to Socket evtuntede Controller Terminals Figure 6 CVTPRO N2 Connection to Controllers with Screw Terminals Connecting the CVTPRO Converter to a Controller with a N2 Jack To connect the CVTPRO converter to a controller wit
8. ons 309 C 86 F Maximum Dew Point Shipping Weight 0 227 kg 0 5 Ib The performance specifications are nominal and conform to acceptable industry standards For application at conditions beyond these specifications consult the local Johnson Controls office Johnson Controls Inc shall not be liable for damages resulting from misapplication or misuse of its products Refer to the Auxiliary Gear Technical Bulletin LIT 6363080 for necessary information on ordering operation and performance specifications of this product JRHNSON CONTRELS Controls Group 507 E Michigan Street P O Box 423 Milwaukee WI 53201 6 AS CVTPROx00 1 Zone Bus N2 Bus Interface Converter Installation Instructions Published in U S A www johnsoncontrols com
9. ration Tool N2 Bus Windows 98 SE Windows NT XTM 105 XPx xxx Windows 2000PE OS NDM Configuration Tool N2 Bus Windows 98 SE Windows NT NDM Windows 2000PE OS Note The CVTPRO converter is not compatible with Zone Terminal Units ZTUs For ZTUs use the CBLPRO 2 converter See the Auxiliary Gear Technical Bulletin LIT 6363080 for details on Johnson Controls converters 1 For proper CVTPRO converter operation when running on Windows NT OSs Service Pack 6 must be installed 2 For proper CVTPRO converter operation when running on Windows 2000 OSs use the Professional Edition only and Service Pack 2 must be installed 3 On Zone Bus applications running on Windows 2000 OSs HVAC PRO Version 8 04B or later must also be installed When using the VMA14x0 with HVAC PRO software versions prior to Version 8 04B only over the Zone Bus with Windows NT OSs a Device Conflict box appears whenever the user attempts an operation for example upload or download To bypass the box select Yes or No and the box disappears The selected operation continues as expected Battery Power Recommendations The CVTPRO converter requires two user supplied AAA alkaline type batteries on N2 Bus applications when the External Power Adapter is not used Battery life varies depending on the N2 Bus load ambient temperature and type of batteries See Table 5 and observe the following guidelines e Always have a spare set of new batteries on
10. th CVTPRO converter and Palm m125 m130 m5xx Devices Black Box Null Modem Adapter for use with CVTPRO and Palm m100 m105 m125 m130 m5xx Devices Palm HotSync Cable for use with CVTPRO converter and Palm m100 m105 Devices These are the manufacturer s code numbers not Johnson Controls code numbers Order through Johnson Controls e Purchasing ITAS The Dock V Pro adapter is available from Solvepoint Corporation at www palmdock com and local retailers 2 AS CVTPROx00 1 Zone Bus N2 Bus Interface Converter Installation Instructions Connecting to the CVTPRO Converter Figure 5 illustrates the potential connections between a CVTPRO converter and other devices Refer to Table 1 and Table 2 for more information on cables and Palm devices See Figure 6 and Figure 7 for more detail about N2 Bus connections Palm Ill Palm V device with Dock V PRO Adapter or Palm VII TE 6x00 TMZ Room Sensor RJ11 Jack BY 6 Pin Zone Bus Compatible External Power Controller Adapter Serial Port RJ45 Jack 8 Pin CVTPRO Serial Cable RJ11 6 pin Jack for Zone Bus N2 Bus Connection DB9 Port N2 Bus Interface 4 Pin N2 Socket 3 Pin N2 Plug with Tab C Personal Computer DB9 Connector Palm m1xx or m5xx with additional connectors See Table 2 Notes 1 Do not connect the CVTPRO converter to the Palm device and laptop PC at the sa