Home
Jenn-Air W10574732A User's Manual
Contents
1. fN G PE H L I l A 36 91 4 cm B 1534 40 0 cm centerline of cooktop to centerline of gas F 10 26 4 cm recommended minimum cabinet to motor clearance manifold pipe G 12 31 8 cm C 4 10 2 cm H 13 33 0 cm D 6 1 16 8 cm E 18 46 8 cm 1 34 87 3 cm Cabinet Dimensions A 30 76 2 cm on 30 76 2 cm models 36 91 4 cm on 36 91 4 cm models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet 24 61 0 cm minimum clearance if bottom of wood or metal cabinet is covered by not less than 14 0 6 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 04 cm stainless steel or 0 024 0 06 cm aluminum or 0 020 0 05 cm copper D 13 33 0 cm recommended upper cabinet depth E 2 5 4 cm F 19 e 50 6 cm G 18 45 7 cm minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop H Junction box or outlet 12 30 5 cm minimum from bottom of countertop Junction box or outlet 10 25 4 cm from right hand side of cabinet J 28 72 7 cm on 30 76 2 cm models 3434 88 3 cm on 36 91 4 cm models K 6 15 2 cm minimum distance
2. t homologu e par CSA International pour l alimentation au gaz naturel ou pour l alimentation au propane apr s conversion ad quate m Cette table de cuisson a t configur e l usine pour l alimentation au gaz naturel Pour la conversion pour l alimentation au propane voir les instructions Conversion pour l alimentation au propane dans le sachet de documentation La plaque signal tique situ e sur la face inf rieure de la base de la table de cuisson indique les types de gaz utilisables Si le type de gaz disponible n est pas mentionn sur la plaque signal tique consulter le fournisseur de gaz local Conversion pour l alimentation au propane L op ration de conversion doit tre ex cut e par un technicien de r paration qualifi Ne pas entreprendre de convertir la table de cuisson pour l utilisation d un gaz diff rent de celui indiqu sur la plaque signal tique sans d abord consulter le fournisseur de gaz Voir les instructions de conversion de gaz fournies dans le sachet de documentation 19 Canalisation de gaz m Installer une canalisation de gaz rigide de 34 1 9 cm jusqu l emplacement d installation de la table de cuisson L emploi d une canalisation de plus petit diam tre sur un circuit plus long peut causer une d ficience du d bit d alimentation On doit utiliser un compos d tanch it des tuyauteries r sistant l action du gaz propane Ne pas utiliser de ruban TEFLON Pour l alime
3. Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock 4 Plug into a grounded 3 prong outlet A Access cap B Rear of cooktop C Gas pressure regulator D Up arrow Regulator must be installed with arrow pointing up to cooktop bottom IMPORTANT All connections must be wrench tightened Do not make connections to the gas regulator too tight Making the connections too tight may crack the regulator and cause a gas leak Do not allow the regulator to turn on the pipe when tightening fittings Use only pipe joint compound made for use with Natural and LP gas Do not use TEFLON tape You will need to determine the fittings required depending on your installation 11 Initial lighting and gas flame adjustments This cooktop is equipped for electronic auto reignition by means of a spark igniter located at the rear of each burner The burners are designed to light at any valve rotation that admits sufficient gas flow to support a flame and to automatically relight following a loss of flame due to a draft or other adverse condition This feature is provided only as a convenience Check Operation of Surface Burners Push in and turn the surface burners control knobs to light The surface burner flame should light within 4 seconds The first time a surface burner is lit
4. me d allumage lectronique 24 Complete Installation 12 Achever l installation iii 24 COOKTOP SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately A DANGER follow instructions You can be killed or seriously injured if you don t follow A WARN l N G instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT Installateur Remettre les instructions d installation au propri taire Propri taire Conserver les instructions d installation pour r f rence ult rieure W10574732A WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vici
5. de Jenn Air Commander la pi ce num ro A406 Clapet de bouche de d charge murale a surface de 3 x 10 8 3 x 25 4 cm de Jenn Air Commander la pi ce num ro A403 Pour commander voir la section Assistance ou service du Guide d utilisation et d entretien V rifier les codes locaux et consulter le fournisseur de gaz V rifier l alimentation en gaz et l alimentation lectrique existantes Voir les sections Sp cifications lectriques et Sp cifications de l alimentation en gaz ll est recommand de faire r aliser tous les raccordements lectriques par un lectricien qualifi agr 14 IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Lors de l installation de la table de cuisson utiliser les dimensions minimums indiqu es m C est l installateur qu incombe la responsabilit de respecter les distances de s paration exig es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique se trouve sur le c t de la chambre de distribution aspiration par le bas m Afin de supprimer le risque de br lures ou d incendie en se penchant au dessus des unit s de surface chauff es le rangement en armoire au dessus des unit s de surface doit tre vit Si un rangement en armoire est envisag le risque peut tre r duit par l installation d une hotte de cuisine op rant horizontalement sur un minimum de 5 12 7 cm au del du bas de
6. elevations above 2 000 ft 609 6 m ratings should be reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada Gas Supply Pressure Testing Gas supply pressure for testing regulator must be at least 1 water column pressure above the manifold pressure shown on the model serial rating plate Line pressure testing above 12 psi gauge 14 WCP The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 2 psi 3 5 kPa Line pressure testing at 2 psi gauge 14 WCP or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 2 psi 3 5 kPa INSTALLATION INSTRUCTIONS Decide on the final location for the cooktop AWARNING Excessive Weight Hazard Use two or more people to move and install cooktop Failure to do so can result in back or other injury Open carton as instructed on product packaging Remove shipping materials and tape from cooktop Remove the removable grease filter by lifting the filter out For island or peninsula installations go to the Rotate Blower Optional section PB D A Removable grease filter 5 Using 2 or more people remove the cooktop from the carton REMEMBE
7. installer un four encastr sous plan de travail sous ce produit IMPORTANT Afin d viter d endommager les placards consulter le constructeur de la maison ou le fabricant des placards pour d terminer si les mat riaux utilis s peuvent subir un changement de couleur une d stratification ou d autres dommages Cette table de cuisson a t congue conform ment aux exigences des normes UL et CSA International et respecte les temp ratures maximales permises de 194 F 90 C pour les placards en bois R sidence mobile Sp cifications additionnelles a respecter lors de l installation L installation de cette table de cuisson doit tre conforme aux dispositions de la norme Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 anciennement Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Lorsque cette norme n est pas applicable utiliser la norme Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A ou respecter les dispositions des codes locaux m Au Canada l installation de cette table de cuisson doit satisfaire aux stipulations de la version la plus r cente de la norme CAN CSA A240 ou des codes locaux en vigueur Dimensions du produit Table de cuisson de 30 76 2 cm c A 21 54 6 cm B 19 1746 50 0 cm C Emplacement de la plaque signal tique Z C ig J a i E 18 46 8 cm F D gagement minimal recommand de
8. it may take longer that 4 seconds to light because of air in the gas line Check the flame on HIGH for a blue color It should be clean and soft in character No yellow tip blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas After verifying the proper burner operation turn the control knobs to OFF If burners do not light properly m Turn surface burner control knob to the OFF position m Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown m Check that the gas shutoff valves are set to the open position m Check that burner caps are properly positioned on burner bases Recheck operation of surface burners If a burner does not light at this point contact your dealer or authorized service company for assistance Adjust Flame Height Smart Port Burner System This cooktop is equipped with a Smart Port Burner System The Smart Port Burner System produces a small flame directly under each grate finger and a larger flame between each grate finger The visual difference between the ports will be noticeable when the burner is used or when adjustments are made to the flame length Adjust the height of top burner flames The cooktop low burner flame should be a steady blue flame approximately 1 4 0 64 cm high i U A Low flame B High flame 12 To adjust stan
9. the International Residential Codes Section M1601 1 2006 edition Do not install 2 elbows together Use no more than three 90 elbows If an elbow is used install it as far away as possible from the hood s vent motor exhaust opening m Make sure there is a minimum of 18 45 7 cm of straight vent between the elbows if more than one elbow is used m Elbows too close together can cause excess turbulence that reduces airflow m Donotuse a 5 12 7 cm elbow in a6 15 2 cm or 3 x 10 8 3 x 25 4 cm system m Do not reduce to a 5 12 7 cm system after using 6 15 2 cm or 3 x 10 8 3 x 25 4 cm fittings m Avoid forming handmade crimps Handmade crimps may restrict airflow m Use a Jenn Air vent cap for proper performance If an alternate wall or roof cap is used be certain the cap size is not reduced and that it has a backdraft damper Use vent clamps to seal all joints in the vent system Use caulking to seal exterior wall or roof opening around the cap The length of vent system and number of elbows should be kept to a minimum to provide efficient performance The maximum equivalent length of the vent system is 60 ft 18 3 m For altitudes above 4 500 ft 1272 m reduce recommended vent run by 20 for best performance Cold Weather Installations An additional backdraft damper should be installed to minimize backward cold air flow and a thermal break installed to minimize conduction of outside temp
10. to nearest left and right side combustible surface above cooktop L 2 5 1 cm minimum clearance between back wall and countertop M Gas line opening Wall anywhere 6 15 2 cm below underside of countertop Cabinet floor anywhere within 6 15 2 cm of rear wall is recommended N 25 63 5 cm depth of countertop NOTES After making the countertop cutout some installations may require notching down the base cabinet side walls to clear the cooktop base To avoid this modification use a base cabinet with sidewalls wider than the cutout m A minimum side clearance of 6 15 2 cm is recommended between side of cooktop and side wall for maximum ventilation performance m A minimum clearance of 2 5 1 cm is recommended between the motor blower and cabinet for proper cooling A 6 15 2 cm clearance is recommended for servicing access Cutout Dimensions A 28 72 7 cm maximum on 30 76 2 cm models 3454 88 3 cm maximum on 36 91 4 cm models B 19 6 50 6 cm maximum on both 30 76 2 cm and 36 91 4 cm models C 8 21 6 cm on 30 76 2 cm models 17 2 44 4 cm on 36 91 4 cm models D 5 14 6 cm on both 30 76 2 cm and 36 91 4 cm models E 2 5 4 cm minimum space to front edge of cooktop F Floor exhaust option G 6 15 6 cm for 6 vent system H 8 21 6 cm on 30 76 2 cm models 17 44 4 cm on 36 91 4 cm models 1 16 40 6 cm on both 30 76 2 cm and 36 91 4 c
11. vacuation est la plus appropri e Pour obtenir la meilleure performance m Utiliser un conduit de ventilation en acier galvanis d paisseur minimum n 26 ou en aluminium d paisseur minimum n 25 Des raccords de mauvaise qualit peuvent r duire le flux d air On d conseille l emploi d un conduit en m tal flexible REMARQUE Les codes locaux pourraient exiger un mat riau plus pais m Le conduit m tallique peut tre r duit une paisseur n 30 pour l acier galvanis ou n 26 pour l acier aluminis si c est permis par les codes locaux Cette information est bas e sur le contenu de la Section des Codes R sidentiels Internationaux M1601 1 dition 2006 Ne pas installer 2 coudes ensemble Ne pas utiliser plus de trois coudes 90 Si l on utilise un coude on doit le placer le plus loin possible de l ouverture d vacuation du moteur de la hotte de ventilation m Veiller incorporer une section de conduit rectiligne d au moins 18 45 7 cm entre deux raccords coud s adjacents m Des coudes trop rapproch s peuvent occasionner une turbulence excessive qui r duirait la circulation de l air m Ne pas utiliser un coude de 5 12 7 cm dans un syst me de 6 15 2 cm ou 3 x 10 8 3 x 25 4 cm m Ne pas r duire le syst me une longueur de 5 12 7 cm apr s avoir utilis des raccords de 6 15 2 cm ou de 3 4 x 10 8 3 x 25 4 cm m viter le sertissage manuel Cela pourrait restr
12. your cooktop to check the airflow see card for step by step instructions a If you need Assistance or Service Please reference the Assistance or Service section of the Use and Care Guide or contact the dealer from whom you purchased your cooktop SECURITE DE LA TABLE DE CUISSON Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves a vous et a d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de blessure grave si vous ne A DAN G E R suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous A AVERTISSEM ENT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions AVERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement observ s un incendie ou une explosion peut survenir causant des dommages au produit des blessures
13. 0 ft 9 1 m max L 6 15 2 cm round 90 PVC sewer pipe elbow M 6 15 2 cm round PVC coupling N 12 30 5 cm minimum Jenn Air Duct Free Filter Accessory Kit For model numbers JED3430 JED3536 JED4430 JED4536 JGD3430 and JGD3536 On select downdraft models the Jenn Air Duct Free Filter Accessory Kit Part Number JDA7000WX is now available The Jenn Air Duct Free Filter Accessory Kit is ideal for both new construction and kitchen renovation projects because it provides an easy alternative to the installation of metal ducting and venting in the downdraft system outside the home The kit includes all required hardware one filter and complete installation instructions For more information on the Jenn Air Duct Free Filter Accessory Kit contact your Jenn Air dealer or call 1 800 JENNAIR 1 800 536 6247 Calculating Vent System Length To calculate the length of the system you need add the equivalent feet meters for each vent piece used in the system Vent Piece 6 15 2 cm Round 45 elbow 2 5 ft 0 8 m S 90 elbow 5 0 ft 1 5m S 6 15 2 cm 0 0 ft wall cap 0 0 m 3 x 10 8 3 cm x 25 4cm 4 5ft to 6 15 2 cm transition 1 4m 6 15 2 cm to 3 x 10 1ft 8 3 cm x 25 4 cm transition 0 3 m 3 x 10 8 3 cm x 25 4cm 5 0ft to 6 15 2 cm 90 elbow 1 5 m transition 6 15 2 cm to 3 x 10 5 0 ft 8 3 cm x 25 4 cm 90 elbow 1 5 m transition 3 x 10 8 3 cm
14. 1 1 6 4 3 cm entre le placard et le moteur G 12 31 8 cm H 14 85 6 cm 1 28 71 4 cm A 30 76 2 cm B 12 e 32 9 cm entre l axe central de la table de cuisson et l axe central de la tubulure de distribution de gaz C 4 10 2 cm D 6 1 2 16 8 cm Table de cuisson de 36 91 4 cm A 212 54 6 cm B 19 Ve 50 0 cm C Emplacement de la plaque signal tique A 36 91 4 cm B 15 40 0 cm entre l axe central de la table de cuisson et l axe central de la tubulure de distribution de gaz C 4 10 2 cm D 6 1 2 16 8 cm H E 18 6 46 8 cm F D gagement minimal recommand de 103 26 4 cm entre le placard et le moteur G 12 31 8 cm H 13 33 0 cm 1 34 87 3 cm 15 Dimensions du placard A 30 76 2 cm sur les mod les de 30 76 2 cm 36 91 4 cm sur les mod les de 36 91 4 cm B Zone de mati re combustible au dessus du plan de travail espace d limit par des lignes pointill es ci dessus C Distance minimale de s paration de 30 76 2 cm entre le dessus de la table de cuisson et le fond d un placard m tallique ou de bois non couvert distance de s paration de 24 61 cm ou plus si le fond du placard de m tal ou de bois est recouvert d une plaque d au moins 1 4 0 6 cm de mat riau r sistant aux flammes lui m me recouvert d une feuille m tallique d une paisseur correspondant un calibre de 28 au m
15. JENN AIR 30 76 2 CM AND 36 91 4 CM GAS DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DE LA TABLE DE CUISSON A GAZ A ASPIRATION PAR LE BAS DE 30 76 2 CM ET DE 36 91 4 CM Table of Contents Table des mati res COOKTOP SAFETY tiseiciesscscsiccecesececetsotecksuccceiceccescdesesncbiuneesectcesecse 1 S CURIT DE LA TABLE DE CUISSON nnssnnnnnnnnnonnne11ennnnnnne 13 INSTALLATION REQUIREMENTS sn 3 EXIGENCES D INSTALLATION sccscceeeeseeeeeeeseeneneneeneesees 14 Tools and P rts 2 3 Outillage et pi ces ss 14 Location Requirements ss 3 Exigences d emplacement 14 Venting Requirement ccecccececeeeeeeeeeeeeeeeeeeeeeeeeeeeseneeseaeessaees 5 Exigences concernant l vacuation 16 Venting Methods sissien Eana 6 M thodes d vacuation 17 Electrical Requirement ccsscceccseceseeeeeeeceeeeeseeeeeesereseeeneees 7 Sp cifications lectriques sicaire 19 Gas Supply Requirement cccccecesceeeeeeeeeeeseeeeeneeseeeseeeees 8 Sp cifications de l alimentation en gaz 19 INSTALLATION INSTRUCTIONS mn 9 INSTRUCTIONS D INSTALLATION mener 21 Install COOKtOP riisiin fiat inner drnneiineratenaeleeren ati 9 Installation de la table de cuisson 21 Rotate Blower Optional ss 9 Rotation du ventilateur Facultative 21 Make Gas Connection 10 Raccordement au gaz 22 Electronic Ignition System 12 Syst
16. MPORTANT La table de cuisson doit tre correctement reli e a la terre en conformit avec les codes et r glements locaux en vigueur ou en l absence de tels codes avec le National Electrical Code ANSI NFPA 70 ou le Code canadien des installations lectriques CSA C22 1 Cette table de cuisson est dot e d un syst me d allumage lectronique qui ne fonctionnera pas en cas de branchement dans une prise qui n est pas correctement polaris e Si les codes le permettent et si on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre Pour obtenir un exemplaire de la norme des codes ci dessus contacter National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 m L appareil doit tre aliment par un circuit de 120 V CA seulement 60 Hz 15 amp res prot g par fusible On recommande galement d utiliser un fusible ou un disjoncteur temporis Il est recommand de raccorder la table de cuisson sur un circuit distinct exclusif cet appareil m Les syst mes d allumage lectronique fonctionnent avec des limites de tension tendues mais une liaison la terre correcte et une polarit appropri e sont n cessaires V rifier que la prise fournit une alimentation de 120 V et qu elle est correctement reli e la terre m Les sch
17. R An undercounter built in oven cannot be installed under this cooktop 6 Place cooktop right side up into the cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from the cutout to avoid scratching the countertop 7 Connect blower exhaust scroll to ducting 8 Use vent clamps to secure the ducting to the blower exhaust scroll 9 Reinstall grease filter 10 Reinstall vent grille IMPORTANT The following additional steps must be performed if the product is being installed in peninsula or island cabinetry The blower exhaust scroll is shipped from the factory set to exhaust straight out the back of the cabinet through an exterior wall A Blower exhaust scroll B Plenum C Blower motor D Top label E 10 32 machine nuts 4 F Motor mounting plate To rotate blower 1 Locate the 4 plastic plugs in the plenum bypass 2 Use the pliers to remove the plastic plugs IMPORTANT Do not throw away the plastic plugs The plastic plugs must be reinstalled after the blower exhaust scroll has been rotated A Blower motor B Exhaust scroll C Plenum D Blower bypass E Plastic plugs 4 3 Insert the socket and extension into the hole and use the 4 Verify the Top label is positioned as shown ratchet handle to loosen the nut half of a rotation Repeat this process for each of the 4 nuts 4 With t
18. as Conversion instructions provided in the package containing literature The model serial rating plate located on the underside of the cooktop base has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP Gas Conversion Conversion must be done by a qualified service technician No attempt shall be made to convert the cooktop from the gas specified on the model serial rating plate for use with a different gas without consulting the serving gas supplier See the Gas Conversion instructions provided in the package containing literature Gas Supply Line m Provide a gas supply line of 34 1 9 cm rigid pipe to the cooktop location A smaller size pipe on longer runs may result in insufficient gas supply Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape With LP gas piping or tubing size should be Ye minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector m If local codes permit use a 1 2 or 3 4 I D flexible stainless steel tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line Ses m AZ male pipe thread is needed for connection to the female pipe threads of the inlet to the cooktop pressure regulator m Do not kink or damage the flexible metal tubing when movin
19. dard burners The flame can be adjusted using the adjustment screw in the center of the valve stem The valve stem is located directly underneath the control knob If the low flame needs to be adjusted 1 Light 1 burner and turn to lowest setting 2 Remove the control knob 3 Hold the knob stem in the low position using a pair of pliers Use an 3 0 mm flat blade screwdriver to turn the screw located in the center of the control knob stem until the flame is the proper size 4 Replace the control knob 5 Test the flame by turning the control from LO to HI checking the flame at each setting 6 Repeat above steps for each burner 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all your tools Dispose of recycle all packaging materials 4 Use a mild solution of liquid household cleaner and warm water to clean cooktop before use Dry thoroughly with a soft cloth For more information see the Cooktop Care section of the Use and Care Guide 5 Read Cooktop Use in the cooktop Use and Care Guide 6 Reconnect power NOTE If the cooktop does not work after turning on the power check that a circuit breaker has not tripped or a household fuse has not blown See Troubleshooting section in the Use and Care Guide for further information 7 Use the Flow Tester Card provided with
20. de la table installation il soit n cessaire d entailler les parois lat rales du de cuisson Pour viter cette modification utiliser un placard inf rieur dont la largeur des parois lat rales est sup rieure celle de l ouverture d coup e Un d gagement minimum de 6 15 2 cm entre le c t de la table de cuisson et la paroi lat rale est recommand pour une performance maximale de ventilation Un d gagement minimum de 2 5 1 cm entre le moteur ventilateur et le placard est recommand pour que le refroidissement puisse s effectuer correctement Un d gagement de 6 15 2 cm est recommand pour avoir acc s en cas de r parations 16 Dimensions de l ouverture d couper A 28 72 7 cm maximum sur les mod les de 30 76 2 cm 3434 88 3 cm maximum sur les mod les de 36 91 4 cm B 19 e 50 6 cm maximum sur les mod les de 30 76 2 cm et de 36 91 4 cm C 8 21 6 cm sur les mod les de 30 76 2 cm 17 2 44 4 cm sur les mod les de 36 91 4 cm D 534 14 6 cm sur les mod les de 30 76 2 cm et de 36 91 4 cm E D gagement minimal de 2 5 4 cm jusqu au rebord avant de la table de cuisson F Option d vacuation par le plancher G 6 15 6 cm pour un syst me d vacuation de 6 H 8 21 6 cm sur les mod les de 30 76 2 cm 17 2 44 4 cm sur les mod les de 36 91 4 cm 1 16 40 6 cm sur les mod les de 30 76 2 cm et de 36 91 4 cm J Op
21. e d une cl cliquet quip e d une douille de 3 et de cuisson tout en soutenant le moteur d une main retirer les crous m taux fixant le moteur de ventilateur la volute d vacuation Retirer le moteur du ventilateur et l assemblage de roues des goujons soud s AVERTISSEMENT Risque d explosion Utiliser une canalisation neuve d arriv e de gaz approuv e par la CSA International Installer un robinet d arr t Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexion au gaz propane demander une personne qualifi e de s assurer que la pression de gaz A Etiquette sur surface sup rieure B Moteur du ventilateur C Platine de montage du moteur D Emplacement du goujon soud E Roue du ventilateur Lorsque la platine de montage du moteur est d gag e des goujons soud s filet s faire pivoter l assemblage dans le sens horaire de 90 et r installer les quatre boulons usin s n 10 32 1 ne d passe pas 36 cm 14 po de la colonne d eau Par personne qualifi e on comprend le personnel autoris de chauffage le personnel autoris d une compagnie de gaz et le personnel d entretien autoris Le non respect de ces instructions peut causer un d c s une explosion ou un incendie Appliquer un compos d tanch it pour tuyauteries con u pour une utilisation avec du gaz naturel ou du gaz propane sur l extr mit filet e la plus pet
22. eindre le flux d air m Utiliser un clapet de conduit Jenn Air pour que le rendement soit correct Si une bouche de d charge murale ou de toit est utilis e s assurer que la taille de la bouche de d charge n est pas r duite et qu elle comporte un clapet anti reflux m Au niveau de chaque jointure du circuit d vacuation assurer l tanch it avec les brides de serrage m l aide d un produit de calfeutrage assurer l tanch it autour de la bouche de d charge l ext rieur travers le mur ou le toit La longueur du syst me d vacuation et le nombre de coudes doit tre r duit au minimum pour une performance efficace La longueur maximale quivalente du circuit d vacuation est de 60 pi 18 3 m Pour les altitudes exc dant 4 500 pi 1 272 m r duire la longueur du syst me d vacuation de 20 pour une performance optimale Installations pour r gions climat froid On devrait installer un clapet anti reflux additionnel pour minimiser le reflux d air froid et incorporer un l ment d isolation thermique pour minimiser la conduction de chaleur par l interm diaire du conduit d vacuation de l int rieur de la maison l ext rieur Le clapet anti reflux doit tre plac du c t air froid par rapport l l ment d isolation thermique Air d appoint Le code du b timent local peut exiger l emploi d un syst me de renouvellement de l air introduction d air d appoint lors de l
23. er la table de cuisson Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure 1 Ouvrir le carton tel que stipul sur l emballage du produit 2 Enlever les mat riaux d exp dition et le ruban adh sif de la table de cuisson 8 Retirer le filtre graisse amovible en le soulevant 4 Pour des installations en lot ou en p ninsule passer la section Rotation du ventilateur Facultative A B 5 RN A Volute d vacuation du D tiquette sur surface ventilateur Sup rieure B Chambre de distribution E 4 crous m taux de 10 32 C Moteur du ventilateur F Platine de montage du moteur Pour faire pivoter le ventilateur 1 Rep rer les 4 bouchons en plastique dans le syst me de Filtre graisse amovible d rivation de la chambre de distribution are Retirer les bouchons d obturation en plastique l aide d une 5 A l aide d au moins 2 personnes retirer la table de cuisson du pince P q carton f i IMPORTANT Ne pas jeter les bouchons d obturation en NE site panne i est i jeer aes un four plastique Les bouchons d obturation en plastique doivent encaSiTe SOUS Piel CAS traval SOUS CENE avis Ge CUISSON tre r install s apr s que l on ait fait pivot la volute 6 Placer la table de cuisson dans l ouverture face sup rieure d vacuation du ventilateur vers le haut REMARQUE S assurer que le bord avant de la table de cuisson est parall le au bord avant du p
24. eratures as part of the vent system The damper should be on the cold air side of the thermal break Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area Common venting methods are shown for a counter mounted downdraft cooktop The cooktop may be vented through the wall or floor Option 1 Roof Venting Option 2 Wall Venting B B Hy uu NV AF A l A A Roof cap A 6 15 2 cm round wall venting B 6 15 2 cm round roof venting B Wall cap Option 3 Venting Between Floor Joist Option 4 Venting behind Cabinet Kick Plate con 3 Ya x 10 8 3 x 25 4 cm A Wall cap B 6 15 2 cm round wall venting A Wall cap B 6 15 2 cm round wall venting Concrete Slab Installations Exhaust Through Wall A Wall cap B 6 15 2 cm round metal vent C 16 40 6 cm maximum D 6 15 2 cm round PVC sewer pipe E 6 15 2 cm round metal vent F 6 15 2 cm round PVC coupling G Concrete slab H 6 15 2 cm round PVC sewer pipe 1 6 15 2 cm round 90 PVC sewer pipe elbow J Tightly pack gravel or sand completely around pipe K 3
25. ettoyant domestique et d eau ti de pour la nettoyer S cher parfaitement avec un linge doux Pour plus de renseignements voir la section Entretien de la table de cuisson du Guide d utilisation et d entretien 5 Lire Utilisation de la table de cuisson dans le Guide d utilisation et d entretien de la table de cuisson 6 Reconnecter la source de courant lectrique REMARQUE Si la table de cuisson ne fonctionne pas apr s la mise sous tension v rifier que le disjoncteur ne s est pas d clench ou que les fusibles ne sont pas grill s Voir la section D pannage dans le Guide d utilisation et d entretien pour plus de renseignements 7 Utiliser la carte de test du flux d air fournie avec la table de cuisson pour v rifier le flux d air voir la carte pour des instructions tape par tape a Si vous avez besoin d assistance ou de service Consulter la section Assistance ou service du Guide d utilisation et d entretien ou contacter le marchand aupr s duquel la table de cuisson a t achet e 2 13 Printed in U S A Imprim aux E U
26. g the cooktop Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the cooktop The rigid pipe must be level with the cooktop connection All strains must be removed from the supply and fuel lines so cooktop will be level and in line m Must include a shutoff valve The supply line must be equipped with a manual shutoff valve This valve should be located in the same room but external to the cooktop opening such as an adjacent cabinet It must be accessible without removing the cooktop and it should be in a location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the cooktop A Gas supply line B Shutoff valve open position C To cooktop Gas Pressure Regulator The gas pressure regulator supplied with this cooktop must be used The inlet pressure to the regulator should be as follows for proper operation Natural Gas Minimum pressure 5 12 7 cm WCP Maximum pressure 7 to 14 17 8 cm to 35 5 cm WCP LP Gas Minimum pressure 10 25 4 cm WCP Maximum pressure 14 35 5 cm WCP Contact local gas supplier if you are not sure about the inlet pressure T TEFLON is a registered trademark of E I Du Pont De Nemours and Company Burner Input Requirements Input ratings shown on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For
27. he nuts loosened the blower exhaust scroll can be easily rotated downward 5 Retighten each nut with the socket extension and ratchet gt A Top label 6 Reinstall the 4 plastic plugs 5 Follow steps 5 10 in the Install Cooktop section To rotate blower motor NOTE The Top label location on the blower motor is at the 9 o clock position 1 Using a ratchet with a socket and supporting the motor with one hand remove the 4 machine nuts that attach the blower motor to the exhaust scroll A WARN l NG 2 Remove the blower motor and wheel assembly from the weld studs Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel A Top label D Weld stud location B Blower motor E Blower wheel Failure to do so can result in death explosion or fire C Motor mounting plate 1 Apply pipe joint compound made for use with Natural and LP 3 When the motor mounting plate clears the threaded weld gas to the smaller thread ends of the flexible connector studs rotate the assembly clockwise 90 and reinstall the adapters see C and G in the following illustrati
28. husetts les instructions d installation suivantes sont applicables m Les travaux d installation et r paration doivent tre ex cut s par un plombier ou tuyauteur qualifi ou licenci ou par le personnel qualifi d une entreprise licenci e par l tat du Massachusetts m Si une vanne boisseau sph rique est utilis e elle doit comporter une manette T m Si un conduit de raccordement flexible est utilis sa longueur ne doit pas d passer 3 pi EXIGENCES D INSTALLATION Rassembler les outils et composants n cessaires avant d entreprendre l installation Lire et observer les instructions fournies avec chacun des outils de la liste ci dessous Outils n cessaires m M tre ruban m Pince m Tournevis lame plate m Foret de 1 4 m Tournevis Phillips m Scie sauteuse m Perceuse m Cl cliquet avec douille m Niveau oe m Compos d tanch it des raccords filet s r sistant au gaz propane Rallonge pour cl douille de 6 15 2 cm m Marqueur ou crayon q y m Solution non corrosive de d tection des fuites Pi ces fournies m Grille de ventilation Chapeaux de br leur m Pr filtre Grilles de br leur m Trousse de conversion D tendeur pour l alimentation au propane Pi ces n cessaires m Conduits m talliques m Brides de serrage pour conduit d vacuation m Bouche de d charge murale Jenn Air Clapet de bouche de d charge murale a surface arrondie de 6 15 2 cm
29. ials used will not discolor delaminate or sustain other damage This cooktop has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194 F 90 C Mobile Home Additional Installation Requirements The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 When such standard is not applicable use the Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A or local codes m In Canada the installation of this cooktop must conform with the current standards CAN CSA A240 latest edition or with local codes Product Dimensions 30 76 2 cm Cooktop Sy C A 21 54 6 cm B 19 1746 50 0 cm C Model serial rating plate location E L G ia H l F 11746 4 3 cm recommended minimum cabinet to motor clearance A 30 76 2 cm B 12 e 32 9 cm centerline of cooktop to centerline of gas manifold pipe G 12 31 8 cm C 4 10 2 cm H 14 35 6 cm D 6 1242 16 8 cm E 18746 46 8 cm 36 91 4 cm Cooktop 1 28 71 4 cm A 21 54 6 cm B 19 50 0 cm C Model serial rating plate location EE EER ATES I Ear ee lel 1 2 sh 4
30. in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s A B A D bit thermique minimum B D bit thermique maximum W10574732A R glage des br leurs standard La vis de r glage au centre de la tige de commande du robinet permet de r gler la taille des flammes La tige de commande est situ e directement au dessous du bouton de commande S il est n cessaire de r gler la taille des flammes pour le d bit thermique minimum 1 Allumer 1 br leur et le tourner au r glage le plus bas 2 Oter le bouton de commande 3 Immobiliser la tige de commande la position faible avec une pince Utiliser un tournevis lame plate de 4 3 0 mm pour faire tourner la vis situ e au centre de la tige de commande jusqu ce que la flamme atteigne la taille d sir e 4 R installer le bouton de commande 5 Tester le fonctionnement du br leur faire passer le bouton de commande de la position LO basse la position HI lev e et observer les flammes pour chaque r glage 6 R p ter les tapes ci dessus pour chaque br leur 1 V rifier que toutes les pi ces sont maintenant install es S il reste une pi ce passer en revue les diff rentes tapes pour d couvrir laquelle aurait t oubli e 2 V rifier la pr sence de tous les outils liminer recycler tous les mat riaux d emballage 4 Avant d utiliser la table de cuisson utiliser une solution douce de n
31. it d vacuation Pour calculer la longueur effective du circuit d vacuation n cessaire additionner les longueurs quivalentes pieds m tres de tous les composants utilis s dans le syst me Composant Conduit de diam tre de 6 15 2 cm Coude 45 2 5 pi 0 8 m Coude 90 5 pi 1 5 m Bouche de d charge murale de 0 pi 0 m 6 15 2 cm 3 L 18 Raccord de transition de 3 x 10 8 3 cm x 25 4 cm sur 6 15 2 cm 4 5 pi 1 4 m Raccord de transition de 6 15 2 cm 3 x 10 8 3 cm x 25 4 cm 1 pi 0 3 m Coude de transition a 90 de 3 x 10 8 3 cm x 25 4 cm a 6 15 2 cm 5 pi 1 5 m Coude de transition a 90 de 6 5 pi 1 5 m 15 2 cm 3 x 10 8 3 cm x 25 4 cm Coude a 90 de 3 x 10 8 3 cm x 25 4cm 5 pi 1 5 m Coude plat de 34 x 10 8 3 cm x 25 4cm 12 pi 3 7 m Bouche de d charge murale 3 x 10 8 3 cm x 25 4 cm O pi 0 0 m CDE Qr Qi S Exemple de circuit d vacuation bouche de d charge murale coude a 90 lt 6 pi 1 8 m 1 coude a 90 5 pi 1 5 m Section droite de 8 pi 2 4 m 8 pi 2 4 m 1 bouche de d charge murale 0 pi 0 0 m Longueur totale 13 pi 3 9 m REMARQUE On d conseille l emploi d un conduit flexible Un conduit flexible peut causer une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance I
32. ite des adaptateurs de raccord flexible voir C et G dans l illustration suivante Fixer un raccord d adaptation sur le d tendeur et l autre raccord d adaptation sur le robinet d arr t de la canalisation de gaz Serrer les deux raccords d adaptation en prenant soin de ne pas d placer ni faire tourner le d tendeur Utiliser une cl mixte de 1546 et une pince multiprise pour fixer le raccord flexible sur les raccords d adaptation V rifier que le raccord n est pas d form Raccordement typique par raccord flexible T A Entr e de la tubulure de distribution B D tendeur C Utiliser un compos d tanch it pour tuyauteries D Adaptateur doit comporter un filetage male de 12 E Raccord flexible F Adaptateur G Utiliser un compos d tanch it pour tuyauteries H Robinet d arr t manuel I Tuyauterie de gaz de 1 2 ou 3 4 oO U D 7 A 5 i 4 Installer le r gulateur avec la fl che orient e vers le haut vers le fond de la base de la table de cuisson et de mani re ce que le chapeau d acc s du d tendeur soit accessible A Chapeau de l ouverture d acc s B Arri re de la table de cuisson C D tendeur D Fl che vers le haut Le d tendeur doit tre install avec la fl che pointant vers le haut vers le fond de la table de cuisson IMPORTANT Tous les raccords doivent tre bien serr s laide d une cl Ne pas serrer excessivement la connexion sur
33. lairs oranges ceci est d diff rents l ments dans l air ou le gaz Apr s avoir v rifi le bon fonctionnement du br leur tourner les boutons de commande OFF arr t Si les br leurs ne s allument pas correctement m Ramener le bouton de commande du br leur de surface la position OFF m V rifier que le cordon d alimentation est branch qu aucun fusible n est grill et que le disjoncteur ne s est pas d clench m V rifier que chaque robinet d arr t de gaz est la position open ouverture m V rifier que les chapeaux de br leurs sont correctement plac s sur la base des br leurs S assurer nouveau du bon fonctionnement des br leurs Si ce stade un br leur ne s allume pas contacter le revendeur ou un d panneur agr R glage de la taille des flammes Syst me de br leur orifice intelligent Cette table de cuisson est quip e d un syst me de br leur orifice intelligent Ce syst me produit une petite flamme sous les doigts de la grille et une flamme plus longue entre ces doigts La diff rence entre ces orifices est visuellement rep rable lorsque le br leur est allum ou lors du r glage de la longueur des flammes R gler la taille des flammes sur le br leur sup rieur de la table de cuisson Pour le r glage au d bit thermique minimum on doit observer des flammes stables bleues d environ 1 4 0 64 cm 2013 Jenn Air Used under license
34. lan de travail S il est n cessaire de repositionner la table de cuisson la soulever enti rement de l ouverture pour viter de rayer le plan de travail 7 Connecter la volute d vacuation du ventilateur aux conduits 8 Utiliser des brides de conduit pour fixer les conduits la volute d vacuation du ventilateur 9 R installer le filtre graisse 10 R installer la grille de ventilation A Moteur du ventilateur D Syst me de d rivation B Volute d vacuation du ventilateur C Chambre de E Bouchons d obturation distribution en plastique 4 3 Ins rer la douille de et la rallonge dans le trou et utiliser le manche de la cl cliquet pour desserrer l crou d un demi tour R p ter cette op ration pour chacun des 4 crous 21 4 5 6 ll est facile de faire pivoter la volute d vacuation du ventilateur vers le bas une fois les crous desserr s 4 V rifier que l tiquette surface sup rieure est positionn e tel qu illustr Resserrer chaque crou l aide de la douille de de la rallonge et de la cl cliquet R installer les 4 bouchons d obturation en plastique Pour faire pivoter le moteur du ventilateur REMARQUE L tiquette surface sup rieure du moteur de ventilateur se trouve la position de 9 heures 1 22 A Etiquette sur la surface sup rieure 5 Suivre les tapes 5 10 de la section Installation de la table A l aid
35. le d tendeur Un serrage excessif pourrait provoquer une fissuration du d tendeur et une fuite de gaz Lors du serrage d un raccord emp cher le d tendeur de tourner sur le tuyau Utiliser uniquement un compos d tanch it des tuyauteries con u pour l utilisation avec le gaz naturel ou le propane Ne pas utiliser de ruban TEFLON Il sera n cessaire de choisir les raccords utiliser en fonction de la configuration d installation Achever le raccordement Ouvrir le robinet d arr t manuel sur la canalisation de gaz Le robinet est ouvert lorsque la poign e est parall le au conduit d alimentation en gaz ee A Robinet ferm B Robinet ouvert V rifier tous les raccordements en les badigeonnant d une solution de d tection des fuites non corrosive approuv e L apparition de bulles indique la pr sence d une fuite R parer toute fuite ventuelle Oter les chapeaux de br leur de surface et les grilles du sachet de pi ces Aligner les encoches des chapeaux de br leur avec les broches dans la base de chaque br leur Un chapeau de br leur correctement plac doit tre horizontal Si le chapeau de br leur n est pas correctement plac le br leur de surface ne peut s allumer Placer les grilles de br leur sur les br leurs et chapeaux AVERTISSEMENT y Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pa
36. llow the instructions provided with any tools listed here Tools needed m Tape measure m Pliers m Flat blade screwdriver m drill bit m Phillips head screwdriver m Jigsaw m Drill m Ratchet with socket m Level m Pipe joint compound m 6 15 2 cm socket resistant to LP gas extension m Noncorrosive leak detection m Marker or pencil Solution Parts supplied m Vent grill Burner caps m Pre filter Burner grates m LP conversion kit m Pressure regulator Parts needed m Metal ducting m Vent clamps m Jenn Air wall cap Jenn Air 6 15 2 cm Round Surface Wall Cap Damper Order Part Number A406 Jenn Air 3 x 10 8 3 x 25 4 cm Surface Wall Cap Damper Order Part Number A403 To order see the Assistance or Service section of the Use and Care Guide Check local codes and consult gas supplier Check existing gas supply and electrical supply See Electrical Requirements and Gas Supply Requirements sections It is recommended that all electrical connections be made by a licensed qualified electrical installer IMPORTANT Observe all governing codes and ordinances When installing cooktop use minimum dimensions given m tis the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located on side of the downdraft plenum m To eliminate the risk of burns or fire by reaching over the heated surface units cabinet s
37. m au dessus du niveau de la mer non applicable au Canada Test de pressurisation de la canalisation de gaz On doit tester le d tendeur sous une pression sup rieure d au moins 1 colonne d eau la pression de la tubulure de distribution indiqu e sur la plaque signal tique Pressurisation une pression sup rieure 2 Ib po 2 14 colonne d eau Lors de tout test de pressurisation de ce syst me une pression sup rieure 2 Ib po 3 5 kPa on doit d connecter la table de cuisson et son robinet d arr t individuel de la canalisation de gaz Pressurisation une pression inf rieure ou gale 2 Ib po 14 colonne d eau Lors de tout test de pressurisation de la canalisation de gaz une pression gale ou inf rieure 1 2 Ib po 3 5 kPa on doit isoler la table de cuisson de la canalisation de gaz en fermant son robinet d arr t manuel individuel INSTRUCTIONS D INSTALLATION D terminer l emplacement final de la table de cuisson IMPORTANT Les tapes suppl mentaires suivantes doivent tre ex cut es si le produit est install avec une configuration A AV ERTISS EM ENT d b nisterie en p ninsule ou en lot La volute d vacuation est mont e l usine de mani re ce que le syst me d vacuation soit orient directement vers l arri re du placard travers un mur ext rieur Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et install
38. m me pi ce comme par exemple un placard adjacent II doit se trouver en un endroit facilement accessible et qui ne n cessite pas le d montage de la table de cuisson pour les man uvres d ouverture fermeture Ne pas entraver l acc s au robinet d arr t manuel Le robinet d arr t manuel est pr vu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson A Canalisation de gaz B Robinet d arr t position d ouverture C Vers la table de cuisson T TEFLON est une marque d pos e de E I Du Pont De Nemours et Compagnie 20 D tendeur de gaz Le d tendeur fourni avec cette table de cuisson doit tre utilis La pression d alimentation du d tendeur doit tre comme suit pour un fonctionnement correct Gaz naturel Pression minimum 5 12 7 cm colonne d eau Pression maximum 7 14 17 8 cm 35 5 cm colonne d eau Gaz propane Pression minimum 10 25 4 cm colonne d eau Pression maximum 14 35 5 cm colonne d eau En cas d incertitude quant la pression d alimentation tablir contacter le fournisseur de gaz local Caract ristiques d alimentation du br leur Les d bits thermiques indiqu s sur la plaque signal tique correspondent une altitude d utilisation inf rieure ou gale 2000 pi 609 6 m Lorsque l appareil est utilis une altitude sup rieure 2000 pi 609 6 m on doit r duire le d bit thermique indiqu de 4 pour chaque tranche de 1000 pi 304 8
39. m models J Wall exhaust option IMPORTANT This cooktop must be exhausted outdoors unless using the Jenn Air Duct Free Filter Accessory Kit See Venting Methods section m Do not terminate the vent system in an attic or other enclosed area Use a Jenn Air vent cap Vent system must terminate to the outside Use only a 6 15 2 cm round metal vent Rigid metal vent is recommended For best performance do not use plastic or metal foil vent m Before making cutouts make sure there is proper clearance within the wall or floor for the exhaust vent m Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed The size of the vent should be uniform The vent system must have a damper If roof or wall cap has a damper do not use damper supplied with the range hood Use vent clamps to seal all joints in the vent system Use caulking to seal exterior wall or roof opening around the cap m Determine which venting method is best for your application For Best Performance m Use 26 gauge minimum galvanized or 25 gauge minimum aluminum metal vent Poor quality pipe fittings can reduce airflow Flexible metal vent is not recommended NOTE Local codes may require a heavier gauge material m Metal duct may be reduced to 30 gauge galvanized steel or 26 gauge aluminized steel if allowed by local codes This reduction is based on information in
40. mas de c blage sont fournis avec cette table de cuisson Voir la section Sch mas de c blage sur une feuille s par e Les sch mas de c blage se trouvent sur la partie inf rieure de la base de la table de cuisson du c t gauche AVERTISSEMENT Risque d explosion Utiliser une canalisation neuve d arriv e de gaz approuv e par la CSA International Installer un robinet d arr t Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexion au gaz propane demander une personne qualifi e de s assurer que la pression de gaz ne d passe pas 36 cm 14 po de la colonne d eau Par personne qualifi e on comprend le personnel autoris de chauffage le personnel autoris d une compagnie de gaz et le personnel d entretien autoris Le non respect de ces instructions peut causer un d c s une explosion ou un incendie Observer les dispositions de tous les codes et r glements en vigueur IMPORTANT L installation doit satisfaire aux crit res de tous les codes et r glements locaux En l absence de code local l installation doit satisfaire aux prescriptions de la plus r cente dition du code national am ricain en vigueur National Fuel Gas Code ANSI Z223 1 ou la norme CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent tre effectu s selon les instructions du fabricant Type de gaz Gaz naturel La conception de cette table de cuisson a
41. nduit m tallique de dia 6 15 2 cm C 16 40 6 cm maximum D Conduit PVC pour gout de dia 6 15 2 cm E Conduit m tallique de dia 6 15 2 cm F Raccord PVC de dia 6 15 2 cm G Dalle de b ton H Conduit PVC pour gout de dia 6 15 2 cm I Coude 90 en PVC pour gout de dia 6 15 2 cm J Gravier ou sable compact tout autour du tuyau K 30 pi 9 1 m max L Coude a 90 en PVC pour gout de dia 6 15 2 cm M Raccord PVC de dia 6 15 2 cm N 12 30 5 cm minimum Trousse accessoire de filtration sans conduit Jenn Air Pour les mod les num ros JED3430 JED3536 JED4430 JED4536 JGD3430 et JGD3536 Sur certains mod les extraction par le bas la trousse accessoire de filtration sans conduit Jenn Air pi ce n JDA7000WX est d sormais disponible La trousse accessoire de filtration sans conduit Jenn Air est id ale tant pour les nouvelles constructions que les projets de r novation de cuisine parce qu elle offre une alternative facile l installation de conduits m talliques et la d charge de syst me aspiration par le bas vers l ext rieur du domicile Cet ensemble comprend tout le mat riel n cessaire un filtre et des instructions d installation compl tes Pour plus d information concernant la trousse accessoire de filtration sans conduit Jenn Air contacter votre concessionnaire Jenn Air ou composer le 1 800 JENNAIR 1 800 536 6247 Calcul de la longueur effective du circu
42. nity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch e Do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions IMPORTANT Do not install a ventilation system that blows air downward toward this gas cooking appliance This type of ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or unintended operation In the State of Massachusetts the following installation instructions apply m Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts m If using a ball valve it shall be a T handle type m A flexible gas connector when used must not exceed 3 feet INSTALLATION RES AENEIS Gather the required tools and parts before starting installation Read and fo
43. ntation au propane le diam tre du tuyau ou conduit doit tre de 2 ou plus Usuellement le fournisseur de gaz propane d termine les mat riaux utiliser et le diam tre appropri Raccord m tallique flexible m Siles codes locaux le permettent utiliser un connecteur gaz flexible en acier inoxydable de 2 ou 34 de diam tre interne con u par CSA pour raccorder la table de cuisson la canalisation rigide d alimentation en gaz p H m Un raccord avec filetage m le de 2 est n cessaire pour la connexion sur le raccord filetage femelle l entr e du d tendeur de la table de cuisson m Ne pas d former craser ou endommager le tube m tallique flexible lors d un d placement de la table de cuisson Raccordement par un ensemble rigide On doit utiliser une combinaison de raccords pour r aliser un raccordement rigide entre la table de cuisson et la canalisation de gaz Le tuyau rigide doit se trouver au m me niveau que le raccord de connexion de la table de cuisson On doit veiller ne soumettre les sections de canalisation d alimentation et de combustible aucun effort de traction ou flexion pour que la table de cuisson soit d aplomb et correctement align e m Robinet d arr t n cessaire La canalisation d alimentation doit comporter un robinet d arr t manuel Le robinet d arr t manuel doit tre s par de l ouverture d encastrement de la table de cuisson mais doit se trouver dans la
44. oins pour l acier 0 015 0 04 cm pour l acier inoxydable 0 024 0 06 cm pour l aluminium ou 0 020 0 05 cm pour le cuivre D Profondeur recommand e pour les placards sup rieurs 13 33 0 cm E 2 5 4 cm F 19 6 50 6 cm G Distance de s paration minimale de 18 45 7 cm entre le placard sup rieur et le plan de travail avec distance minimale de s paration horizontale pour la table de cuisson H Bo tier de connexion ou prise lectrique 12 30 5 cm ou plus depuis le bas du plan de travail Bo tier de connexion ou prise lectrique 10 25 4 cm depuis le c t droit du placard J 28 72 7 cm sur les mod les de 30 76 2 cm 3454 88 3 cm sur les mod les de 36 91 4 cm K Distance de s paration minimale de 6 15 2 cm par rapport la surface de mat riau combustible la plus proche gauche ou droite au dessus de la table de cuisson L Distance de s paration minimale de 2 5 1 cm ou plus entre la paroi arri re et le plan de travail M Ouverture pour canalisation de gaz mur n importe o 6 15 2 cm au dessous de la face inf rieure du plan de travail Plancher du placard n importe o 6 15 2 cm maximum du mur arri re recommandation N Profondeur de la table de cuisson 25 63 5 cm REMARQUES Apr s le d coupage de l ouverture dans le plan de travail il est possible que pour certaines configurations d placard inf rieur pour permettre le passage de la base
45. on far i NUS 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters being certain not to move or turn the gas pressure regulator 3 Use a 1316 combination wrench and channel lock pliers to attach the flexible connector to the adapters Check that connector is not kinked 10 Typical flexible connection Complete Connection 1 Open the manual shutoff valve in the gas supply line The valve is open when the handle is parallel to the gas pipe A Ds B A Manifold entrance B Gas pressure regulator A Closed valve C C Use pipe joint compound B Open valve D D Adapter must have 72 male pipe thread E Flexible connector 2 Test all connections by brushing on an approved F Adapter noncorrosive leak detection solution If bubbles appear a E G Use pipe joint compound leak is indicated Correct any leak found He Manual gas Shutort valve 3 Remove surface burner caps and grates from parts package 72 or A gas pipe Align notches in burner caps with pins in burner base Burner z caps should be level when properly positioned If burner caps are not properly positioned surface burners will not light Place burner grates over burners and caps AWARNING y Electrical Shock Hazard 4 Install the pressure regulator with the arrow pointing up toward the bottom of the cooktop base and in a position where you can reach the regulator access cap
46. ou un d c s Ne pas entreposer ni utiliser de essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ e Ne pas tenter d allumer un appareil e Ne pas toucher a un commutateur lectrique e Ne pas utiliser le t l phone se trouvant sur les lieux e Appeler imm diatement le fournisseur de gaz a partir du t l phone d un voisin Suivre ses instructions e d faut de joindre votre fournisseur de gaz appeler les pompiers L installation et l entretien doivent tre effectu s par un installateur qualifi une agence de service ou le fournisseur de gaz AVERTISSEMENT L odorat ne permet pas toujours la d tection d une fuite de gaz Les distributeurs de gaz recommandent l emploi d un d tecteur de gaz homologation UL ou CSA Pour d autre information contacter le fournisseur de gaz local En cas de d tection d une fuite de gaz ex cuter les instructions Que faire dans le cas d une odeur de gaz IMPORTANT Ne pas installer un syst me de ventilation avec vacuation de l air vers le bas qui vacuerait l air vers cet appareil de cuisson gaz Ce type de syst me de ventilation peut causer des probl mes d allumage et de combustion avec cet appareil de cuisson gaz et entra ner des blessures corporelles ou le fonctionnement non d sir de cet appareil 13 Dans l tat du Massac
47. s operate within wide voltage limits but proper grounding and polarity are necessary Check that the outlet provides 120 volt power and is correctly grounded m The wiring diagrams are provided with this cooktop See Wiring Diagrams on a separate sheet The wiring diagrams are located on the left underside of the cooktop base AWARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire Observe all governing codes and ordinances IMPORTANT This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI 2223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Leak testing of the cooktop must be conducted according to the manufacturer s instructions Type of Gas Natural Gas This cooktop is design certified by CSA International for use with Natural gas or after proper conversion for use with LP gas m This cooktop is factory set for use with Natural gas If converting to LP gas see the LP G
48. s placards m La table de cuisson doit tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage m Toutes les ouvertures dans le mur ou le plancher de l emplacement d installation de la table de cuisson doivent tre scell es m Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards Ces dimensions constituent les valeurs minimales des d gagements de s paration m Une source d lectricit avec liaison la terre est n cessaire Voir la section Sp cifications lectriques Une source de gaz ad quate doit tre disponible Voir la section Sp cifications de l alimentation en gaz m De par sa conception la table de cuisson est suspendue sur le plan de travail par les rebords des c t s ou de l arri re m Veiller placer les sources de gaz et d lectricit selon les indications de la section Dimensions du placard pour qu elles soient accessibles sans avoir retirer la table de cuisson m Pr voir une ouverture dans l angle sup rieur droit de l enceinte voir l illustration pour le passage de la canalisation de gaz et du c ble d alimentation lectrique et pour que l tiquette signal tique soit visible m Sile placard comporte des tiroirs ces tiroirs doivent tre retir s et l avant des tiroirs install sur l avant du placard IMPORTANT II n est pas possible d
49. s utiliser un adaptateur Ne pas utiliser un c ble de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique 4 Brancher sur une prise de courant 3 alv oles reli e la terre 23 Allumage initial et r glages des flammes de gaz Cette table de cuisson est quip e pour le rallumage lectronique automatique d clench par un allumeur situ l arri re de chaque br leur Les br leurs sont con us pour s allumer n importe quelle rotation de robinet qui permet un d bit de gaz suffisant pour alimenter une flamme et se rallumer automatiquement suite une perte de flamme en raison d un courant d air ou autre situation ind sirable Cette caract ristique est uniquement destin e faciliter l utilisation de la table de cuisson Contr le du fonctionnement des br leurs de surface Enfoncer et tourner les boutons de commande des br leurs de surface la position basse Le gaz doit s enflammer sur le br leur de surface en moins de 4 secondes Lors de l allumage initial du br leur de surface le d lai d allumage peut tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz V rifier que la flamme est bleue la position HIGH lev e Elle doit tre propre et douce On ne doit pas observer de pointe jaune ni d effet de soufflage ou de s paration entre les flammes et le br leur Il est normal d observer parfois des c
50. tion d vacuation par le mur IIMPORTANT L vacuation de cette table de cuisson doit se faire l ext rieur moins d utiliser la trousse accessoire de filtration sans conduit de Jenn Air Voir la section M thodes d vacuation m Ne pas terminer le circuit d vacuation dans un grenier ou dans un autre espace ferm m Utiliser un clapet de conduit Jenn Air m Le syst me doit d charger l air l ext rieur m Utiliser uniquement du conduit m tallique de 6 15 2 cm Un conduit en m tal rigide est recommand Pour un rendement optimal ne pas utiliser de conduit en plastique ou en aluminium m Avant d effectuer des d coupes s assurer qu il y a un d gagement convenable entre le mur ou le plancher pour le conduit d vacuation m On ne doit couper un poteau de colombage ou une solive que si c est absolument n cessaire Dans ce cas on devra construire une structure de support appropri e La taille du conduit doit tre uniforme m Le circuit d vacuation doit comporter un clapet Si la bouche de d charge murale ou par le toit comporte un clapet ne pas utiliser le clapet fourni avec la hotte de cuisini re m Au niveau de chaque jointure du circuit d vacuation assurer l tanch it avec les brides de serrage m l aide d un produit de calfeutrage assurer l tanch it autour de la bouche de d charge l ext rieur travers le mur ou le toit m D terminer quelle m thode d
51. torage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets m The cooktop should be installed in a location away from strong draft areas such as windows doors and strong heating vents or fans All openings in the wall or floor where cooktop is to be installed must be sealed m Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances m Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section m The cooktop is designed to hang from the countertop by its side or rear flanges m The gas and electric supply should be located as shown in Cabinet Dimensions section so that they are accessible without requiring removal of the cooktop m Provide cutout in right rear corner of cabinet enclosure as shown to provide clearance for gas inlet power supply cord and to allow the rating label to be visible m If cabinet has drawers drawers will need to be removed and drawer fronts installed on front of cabinet IMPORTANT An undercounter built in oven cannot be installed under this product IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier to make sure that the mater
52. utilisation d un syst me d aspiration de d bit sup rieur une valeur pieds cubes par minute sp cifi e Le d bit sp cifi en pieds cubes par minute varie d une juridiction l autre Consulter un professionnel des installations de chauffage ventilation climatisation au sujet des exigences sp cifiques applicables dans la juridiction locale Les m thodes d vacuation standard illustr es correspondent une table de cuisson avec aspiration par le bas mont e sur comptoir L vacuation de la table de cuisson peut se faire par le mur ou le plancher Option 1 D charge a travers le toit Option 2 D charge a travers le mur A B RE A Bouche de d charge sur toit B Conduit de dia 6 15 2 cm pour sortie travers le toit A Conduit de dia 6 15 2 cm pour sortie travers le mur B Bouche de d charge murale Option 4 vacuation derri re le garde pieds de la caisse Option 3 vacuation entre les solives au plancher 3 x 10 A 8 3 x 25 4 cm B A B A Bouche de d charge murale B Conduit de dia 6 15 2 cm pour sortie a travers le mur A Bouche de d charge murale B Conduit de dia 6 15 2 cm pour sortie a travers le mur 17 Installations dans dalle de b ton Evacuation a travers le mur B A Bouche de d charge murale B Co
53. x 25 4cm 5 0ft 90 elbow 1 5 m Z 34 x10 83cmx254cm 12 0ft lt 2 flat elbow 3 7 m 3 x 10 8 3 cm x 25 4cm 0 0 ft wall cap 0 0 m Example vent system wall cap 90 elbow 6 ft 1 8 m 1 90 elbow 5 ft 1 5 m 8 ft 2 4 m straight 8 ft 2 4 m 1 wall cap 0 ft 0 m System length 13 ft 3 9 m NOTE Flexible vent is not recommended Flexible vent creates back pressure and air turbulence that greatly reduce performance IMPORTANT The cooktop must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 This cooktop is equipped with an electronic ignition system that will not operate if plugged into an outlet that is not properly polarized If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 m A120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this cooktop be provided m Electronic ignition system
Download Pdf Manuals
Related Search
Related Contents
Antec UCC13# User's Manual TVP 120 220 320 Subscriber`s Guide - City 特注品、試作品の開発はタートル工業にお任せください 研究報告本文 - 千葉の県立博物館 Copyright © All rights reserved.
Failed to retrieve file