Home

Jacuzzi EV77959 User's Manual

image

Contents

1. low gt medium gt high Each wider bar on the LCD graphic display represents one level increase EX93000 Refresh Installation Manual 10 06 O Operation continued Setting the Clock a Press and hold the STOP button on the remote Control for over 5 seconds until the Clock flashes b Use the button to set the HOUR and the button to set the MINUTES Power Save Mode The Refresh Personal Hygiene System includes a power saving feature to reduce electrical consumption when not in use Once set the Power save function turns the Refresh ON and OFF each day according to your programmed time settings Setting the Power save Start and End Times a Press and hold the Power save button for 5 seconds POWER SAVE START on the Remote and the Power save LED on the Refresh will flash LCD PANEL b Adjust the Power save Start time using the WATER FLOW button to set the HOUR and the WATER FLOW button to set the MINUTES When the desired Start time is displayed on the Remote press the Power save button again c POWER SAVE END on the Remote and the Power save LED on the Refresh will flash d Adjust the Power save End time using the WATER FLOW button to set the HOUR and the WATER FLOW button to set the MINUTES When the desired End time is displayed on the Remote press the Power save button again The remote LCD will show POWER SAVE ON and the Power save LED on the Refresh will be green Power save function is now
2. F 35 C MED 100 F 38 C HIGH 104 F 40 C Soft Closing 0 2 gal min 0 72 liter min OFF room temperature LOW 97 F 35 C MED 100 F 38 C HIGH 104 F 40 C Dryer Temperature Electrical Safety Protection Power Cord Length Product Dimensions Product Weight LOW MED HIGH 15mA GFCI 4 ft 1 2m 15 W x 19 Lx 6 H 15 W x 20 1 L x 6 H 383 mm W x 483 mm L x 153 mm H 383 mm W x 511 mm Lx 153 mm H 9 5 lbs 4 3 kg 9 7 lbs 4 4 kg Parts amp Configuration ee Remote Control Mount Kit Batteries Standard Mounting Hardware EX93000 Refresh Installation Manual 10 06 D Alternate Mounting Hardware Installed Configuration Remote Control GFCI y grounded Remote T Valve with outlet lt Mount Filter and Bidet Hose Ee Mounting plate Water Supply Line Universal Wrench Front Nozzle T Valve Back Nozzle Heated Seat Shut Off Valve Typical install time 30 60 minutes Before Installation Tools Needed Flat head screwdriver Universal wrench included Phillips head screwdriver Measuring tape NOTE The included Universal Wrench will work for most applications Depending on your toilet configuration an adjustable wrench may also be needed Alternate Mounting Hardware Some toilets may not provide adequate access to the seat mounting holes preventing proper installation of the Standard Mounting Hardware In this case you will need to use the Alterna
3. ON and the unit will go into Power save mode at the programmed start time Enabling and Disabling the Power save power a Press the Power save button to toggle between Power save ON and Power save OFF a power sav b To change Power save Start and End Times refer to the procedure above seat heat When Power save is Operating peatsenpor a When the Refresh is in Power save mode the Power save LED on the seat will glow ORANGE b Sitting on the Refresh while it is in Power save mode returns the unit to normal operation The Refresh will not re enter the Power save mode until the next day s scheduled start time Auxiliary Controls AUXILIARY CONTROLS backup for Remote There are two 2 buttons on the rear right corner of the Refresh for use when the Remote Control is unavailable Rear Wash Sit on the seat and press the AUX WASH button to begin water flow only posterior cleaning is available when using Auxiliary Controls For each of the operations below you must start in the Rear Wash mode Water Pressure Press the AUX WASH button again until the desired water pressure is achieved Press the AUX STOP button to discontinue the water flow Warm Air Dryer Press the AUX STOP button to activate Warm Air Dryer It will automatically be set to the medium temperature level Press the AUX STOP button again to turn OFF the dryer Seat Temperature To adjust the Seat Temperature press and hold the AUX STOP button for more than 5 se
4. conds Press the AUX STOP button again to change seat temperature low gt medium gt high gt off Water Temperature To adjust the Water Temperature press and hold the AUX WASH button for more than 5 seconds Press the AUX WASH button again to change water temperature low gt medium gt high gt off Remote Control Beeping Silent Modes The remote control has two 2 operational modes Beeping Mode and Silent Mode Beeping mode beeps to confirm when a command from the remote has successfully been received by the seat To change modes press and hold the WATER TEMP button on the remote for 5 seconds O EX93000 Refresh Installation Manual 10 06 Maintenance CAUTION Seat Cleaning and Removal Use a soft damp cloth and mild cleanser such as dish soap to wipe down the seat DO NOT scrub or use harsh abrasive products to clean the Refresh bidet seat For amore thorough cleaning you may remove the Refresh bidet seat To release push the button located on the back right side of the seat and pull the Refresh bidet seat forward Nozzle Cleaning Always unplug the Refresh before cleaning CAUTION Press to Release It is recommended that you clean the retractable nozzles monthly or as necessary To clean the nozzles pull them out gently and use a soft damp brush or cloth to wipe down DO NOT use soap or detergents to clean nozzles Filter Cleaning For proper Refresh bidet seat function it is important to occasionall
5. covered by a limited one year warranty valid from the original date of purchase for original purchaser Please complete and return the enclosed product registration card to receive important product updates
6. efresh PERSONAL HYGIENE SYSTEM Refresh Personal Hygiene System OWNER S MANUAL Round EU44959 ROUND FRONT Elongated EV77959 ELONGATED FRONT This manual contains important safety information Please read carefully before product installation or use EX93000 Refresh Installation Manual 10 06 A AELE LET EL E A CAUTION CAUTION For safety reasons please read this entire manual before installation or use Danger Possibility of electric shock Use the correct voltage according to the specifications and connect to a three prong GFCI grounded outlet Q Btn Please use caution and avoid spraying water directly on the Refresh Personal Hygiene System or power cord This could NOTE This GFCI outlet should be installed prior to performing this installation result in electric shock or fire Model Rated Power Source Tap Water Pressure Rated Power Consumption Seat Temperature Seat amp Lid Maximum Spray Volume Water Temperature Do not use harsh brushes or abrasive detergents to clean the Refresh Personal Hygiene System Use only mild soap and a soft cloth for cleaning Do not disassemble or modify the Refresh Personal Hygiene System Only a authorized service representative should perform repairs E Specifications EU44959 ROUND FRONT EV77959 ELONGATED FRONT 120VAC 15 Amp GFCI 1400W 7 106 psi 0 5 7 5 kgf cm 1 5 kwh OFF room temperature LOW 97
7. full contact with the toilet bowl rim To Release the Refresh Unplug the power plug and turn the water supply valve OFF Push the button located on the right corner of the seat and gently pull Press to 6 Turn ON Water amp Connect Power Release CAUTION Use only a grounded 15 Amp GFCI outlet a Turn the water supply valve ON slowly CAUTION Use only a Ensure the connections are not leaking grounded GFCI outlet before continuing NS i Ves IMPORTANT Make sure work area is dry ig and hands are dry before continuing b Insert power plug into a grounded 15 Amp GFCI outlet The blue power LED on the Refresh Display Panel will illuminate IMPORTANT Make sure the power plug is removed and the water supply is shut off before removing the Refresh 7 Battery Installation a Remove battery cover from Remote Control and insert two 2 AAA batteries included as shown b Refasten battery cover with screw EX93000 Refresh Installation Manual 10 06 Installation continued 8 Remote Control Installation a Identify a location for the Remote Control that is visible and reachable from the toilet and that does not obstruct the IR signal Depending on your wall type you can install the screws directly or use anchor mounts provided as shown b If you prefer to not drill holes in your wall you may use double sided foam tape to adhere bracket to wall In this case make sure to choose a tape wi
8. ime exceeding 5 minutes 2 Power failure 1 Repeat cleaning function 2 Check power and or unplug the cord to reset Seat not heated Water not heating Seat temperature set to OFF Water temperature set to OFF Reset heated seat temperature Reset heated water temperature Water flow sporadic or inconsitent Pulsating Spa mode activated Reset to normal washing mode Dryer not working Dryer only operates when activated by weight of person on seat Sit on Refresh to operate Dryer EX93000 Refresh Installation Manual 10 06 Some features of the Refresh Personal Hygiene System are designed to function only when the seat is occupied REMOTE CONTROL PANEL WARM WATER WASH INDICATOR LIGHTS Posterior Rear Feminine Vaginal Cleansing Cleansing e L Water Temperature _ Low gt Med gt High gt Off power save LCD Panel Seat Temperature seat heat ea Low gt Med gt High gt Off seat sensor Warm Air Dryer On Low gt Med gt High a lt AUXILIARY CONTROLS Si iJ T backup for Remote Decrease Increase Function top Water Pressure for Wash and Dryer Adjustment Using the Refresh Remote Control Warm Water Washing Sit on the seat and press the FRONT or BACK either HIM or HER button to begin water flow Press STOP button to discontinue water flow Water Flow Pressure Adjustment While water is flowing press the button to increase pressu
9. ls a Place Mounting Plate over mounting holes flat side down curve toward the back of the toilet b Insert bolts through the Mounting Plate and finger tighten the wing nuts Make sure the crush washer and metal flat washer are put on in the correct order see graphic Crush Washer Metal Flat Washer E EX93000 Refresh Installation Manual 10 06 Mounting Holes Installation continued 3 Install Mounting Plate continued L c Adjust mounting plate so length L between the front of the toilet Bo bowl and the back of the mounting plate is as follows Round EU44959 L 181 4 465 mm Elongated EV77959 L 2072 495 mm d Tighten Mounting Bolts with screwdriver until the mounting plate is securely fastened to the toilet 4 Connect T Valve and Hoses NOTE If your water supply line is rigid pipe you may need to replace it before installing the Refresh Personal Hygiene System a Install the T Valve between the water supply line and the toilet tank b Place the Refresh on or beside the toilet and connect the Bidet Hose to the Refresh IMPORTANT Use wrench to tighten all connections before continuing Failure to do so could result in flooding leaking or damage to the Refresh Personal Hygiene System Do not overtighten 5 Attach the Refresh a Slide the Refresh onto the mounting plate You will hear a click indicating the seat has been properly attached Confirm that the seat switch is in
10. re or the button to decrease pressure Repeat until desired pressure is reached There are five 5 levels of water pressure Each wider bar on the LCD graphic display represents one level increase LCD Panel 07 21 Pulsating Water Mode To change to Pulsating Mode While water is flowing press the FRONT or BACK either HIM or HER button for over three 3 seconds To deactivate and return to normal washing mode repeat the above step Warm Air Dryer Press the WARM AIR button to start dryer Press STOP to stop the dryer Adjusting Seat Water and Dryer Temperature You must be sitting on the seat for these functions The last entered temperature settings are stored in memory Adjusting Seat Temperature a Press SEAT TEMP button to adjust temperature Repeat until desired level is achieved There are 0721 four 4 temperature levels low gt medium gt high gt off Each wider bar on the LCD graphic display represents one level increase No LCD graphic indicates seat heating is OFF Adjusting Water Temperature Press WATER TEMP button to adjust temperature Repeat until desired level is achieved There are four 4 temperature levels low gt medium gt high gt off Each wider bar on the LCD graphic display represents one level increase No LCD graphic indicates water heating is OFF Adjusting Dryer Temperature Press WARM AIR button to adjust temperature Repeat until desired level is achieved There are three 3 temperature levels
11. te Mounting Hardware and follow the enclosed instructions Check Water Supply Line Check the line that connects the toilet tank to the water shut off valve If it is rigid pipe you may need to purchase a flexible hose to replace it before installing the Refresh Personal Hygiene System The length of the hose and the size of the connectors will vary A Installation A CAUTION CAUTION Please read these carefully before installing the Refresh Personal Hygiene System Failure to do so could result in flooding leaking or damage to the Refresh Personal Hygiene System 1 Remove Toilet Seat Steps may vary by type of seat a Lift hinge covers and use a screwdriver to remove the mounting bolts b Remove the toilet seat 2 Turn OFF Water and Flush Toilet You may wish to place a container under the tank to catch any leaking that could occur during installation a Turn water valve OFF completely If the water valve does not shut OFF completely STOP Repair the water shut off valve before proceeding z b Flush the toilet to empty the tank 3 IMPORTANT Do not continue without completing these c Disconnect water supply line from toilet tank steps Failure to do so could result in flooding leaking or damage to the Refresh Personal Hygiene System 3 Install Mounting Plate NOTE These instructions are for Standard Mounting Hardware See db Alternate Mounting Hardware at the top of this page for further detai
12. th an we adhesive that will not damage wall upon removal 9 Filling the Reservoir a Place a plastic sheet not provided over the seat Sit on the Refresh to activate the seat switch Press one of the wash functions on the Remote Control The reservoir will begin to fill It will take between 5 and 10 seconds for the reservoir to completely fill When the reservoir is full the wash wand will extend and begin to spray Push STOP to cancel the wash function Remove the plastic sheet and discard b Your Refresh bidet seat is now ready for use Refer to the Operation section of this manual for programming and operation instructions Issue Troubleshooting Possible Causes Solution Low water flow or pressure Clogged filter Twisted hose 1 2 3 Household water pressure low 1 Clean filter 2 Straighten hose 3 Increase water pressure to Refresh Nozzles do not function properly Clogged filter Nozzles are dirty Water pressure is too low 1 2 3 1 Clean the nozzles 2 Clean the filters 3 Adjust water pressure Nozzles fail to react Nozzles are dirty Clean nozzles Washing feature does not work or fails to spray 1 User not properly seated 2 Seat switch is not contacting toilet fixture properly 1 Adjust your sitting position 2 Make sure the seat switch is contacting toilet bowl rim switch is in seat foot Product shuts OFF during use 1 Washing t
13. y clean the water filter Frequency of cleaning depends on your local water supply Clogged filters cause decreased water flow affecting operation Remove filters by hand DO NOT operate with filters removed T VALVE FILTER 1 Turn water supply valve OFF NS completely 2 Flush toilet to empty the water J tank Failure to do so could result in leaking or flooding S 4 Gently brush and clean the filter with water to remove build up 5 5 Reconnect the filter to the T Valve 6 Turn the water supply back ON and check for leaks 3 3 Unscrew the filter from the T Valve A S the end not connected to a hose G BIDET HOSE FILTER m 1 Turn water supply valve OFF le completely N e G 2 Flush toilet to empty the water tank Failure to do so could result in leaking or flooding a O z 3 Disconnect the Bidet Hose from the Refresh 4 Gently brush and clean the filter with water to remove build up 5 Reconnect the Bidet Hose to the Refresh 6 Turn the water supply back ON and check for leaks For other issues or questions contact Jacuzzi Customer Service 1 800 288 4002 Contact Information Jacuzzi Whirlpool Bath Customer Service 14801 Quorum Dr Suite 400 Dallas TX 75254 PHONE WEB 1 800 288 4002 www jacuzzi com EX93000 Refresh Installation Manual 10 06 Warranty The Refresh Personal Hygiene System is

Download Pdf Manuals

image

Related Search

Related Contents

product manuals  Toshiba PSAFGU-020002 Laptop User Manual  Multimètre analogique - GMC  GE 60226HD-2PK Instructions / Assembly  - MPW MED. INSTRUMENTS Spółdzielnia Pracy  Downloaded from www.vandenborre.be  Manual de Usuario OT48 v.2.5  MANUALE D`USO PER BARBECUE ELETTRICO  Acer 6492G Laptop User Manual  La Haute-Marne, c`est d`abord une histoire. Une histoire de  