1. thera pure thera pure air purifier with uv light owner s guide Thank you for purchasing the Therapure 101 air purifier With UV germicidal protection to kill germs and permanent HEPA type filtration to purify the air the Therapure 101 air purifier will greatly improve the quality of the air in your home office or other environments We want you to be fully satisfied with your Therapure 101 That s why your Therapure 101 comes with a one year limited warranty Once you ve experienced the purity of Therapure air visit us at our website to find out more ways to improve the quality of your air and your life with our premium products and upgrades at www therapureair com Please be sure to read the following instructions carefully to ensure optimal performance and safety TAGLE OF CONTENTS SAFETY INSTRUCTIONS IMPORTANT WARNINGS UV Lamp Notice Mercury Notice UV Lamp Disposal Notice UV Lamp Breakage PRODUCT BENEFITS MAIN PARTS OPERATING THE THERAPURE 101 AIR PURIFIER Getting Ready Controls Settings OPERATION Selecting a Setting CLEANING amp MAINTENANCE Cleaning the Permanent Filter Cleaning the UV Lamp Cleaning External Surfaces Replacing the UV Lamp TROUBLE SHOOTING ONE YEAR LIMITED WARRANTY ARBITRATION AGREEMENT w w w w Ww 12 13 14 SAFETY INSTRUCTIONS READ amp SAVE THESE INSTRUCTIONS WARNING RISK OF ELECTRICAL SHOCK Safety precautio
2. Controls Settings There is an OFF button and a Speed Knob on the Control Panel Just turn the Speed Knob to the setting you want OFF turns unit off LOW atthis setting the unit will run at low speed MED atthis setting the unit will run at medium speed HI at this setting the unit will run at high speed Press the UV lamp button to turn on the UV lamp to kill harmful airborne bacteria and germs Press it again to turn off the UV lamp Safety 1 Do not blow air directly into air purifier 2 Keep both sides of the unit at least 1 foot away from a wall 3 Donot place the unit near curtains 4 Placing the unit close to the source of air pollution is an effective way to improve indoor air quality _ N Locate a level surface on which to place your Therapure 101 air purifier and a 120V outlet follow warnings in the SAFETY INSTRUCTIONS IMPORTANT WARNINGS sections of this manual Position your Therapure at least one foot 12 inches from the wall Plug in the unit You are now ready to turn on your Therapure 101 air purifier 101M OPERATION CLEANING amp MAINTENANCE To operate your Therapure 101 air purifier rotate the Speed Knob to the speed of your choice to With very little effort the Therapure 101 air purifier delivers cleaner fresher sanitized air to your activate your air purifier There are three speed settings controlled by the Speed Knob The different indoor environments se
3. WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control devices IMPORTANT WARNINGS UV Lamp Notice UV light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision Never look directly at the UV lamp while it is illuminated doing so could cause loss of vision Only view illumination through the window at the front of the unit To prevent exposure to ultraviolet light disconnect the power to the unit before servicing any part of the Therapure 101 air purifier Mercury Notice This device contains mercury in the sealed ultraviolet lamp s Do not place your used lamp s in the trash Disposal of any item containing mercury must be in accordance with any hazardous waste disposal or recycling laws and regulations of your state UV Lamp Disposal If the UV lamp breaks turn off the unit Do not operate the unit with a broken lamp Do not use a vacuum to clean up breakage Sweep debris into a plastic bag and dispose of properly Contact your local waste management authority for instructions regarding recycling and the proper disposal of old lamp s To order a replacement lamp call 1 800 875 8577 or go to www therapureair com PRODUCT BENEFITS Triple action purification 1 Permanent HEPA type Filter takes particles out of the air purifying it 2 UV lamp kills germs such as viruses and bacteria 3 Photo catalyst filter removes VOCs volatile or
4. with your vacuum cleaner Run the attachment along the inlet and outlet side of the filter cleaning between the crevices as much as possible Do not use water or any household cleaners or detergents to clean the Permanent HEPA type Filter Control Panel 101M CLEANING amp MAINTENANCE CLEANING amp MAINTENANCE NOTE Before replacing the UV lamp make sure your Therapure air purifier gt gt Vacuuming will restore performance of the Permanent HEPA type Filter However the is turned off and unplugged filter may appear stained This is normal and does not affect performance in any way Replacing the UV Lamp gt Do not use water or any household cleaners or detergents to clean the Permanent HEPA 1 Take out the screw from the bottom cover see Figure 1 Rotate the cover type Filter counter clockwise to remove the cover gt gt The Permanent HEPA type Filter has been designed to never need replacing However it 2 Pull out the lamp base assembly by rotating the assembly counter clockwise to unlock does need servicing We recommend that under normal conditions of continuous use the 3 Pull out the old UV lamp from the lamp base assembly filters be cleaned every month to maintain optimal functioning 4 Install the new UV lamp into the lamp base assembly gt The inlet grill may be cleaned after unit is turned off and unplugged with a vacuum 5 Insert the UV lamp base assembly into the unit Make sure the UV lamp base assemb
5. TS AND REMEDIES BY PROVIDING THAT DISPUTES BETWEEN YOU AND THE SELLER OF THIS PRODUCT COMPANY MUST BE RESOLVED THROUGH BINDING ARBITRATION RATHER THAN IN A COURT PLEASE READ THIS AGREEMENT CAREFULLY YOU ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING THE PRODUCT S SHIPPED IN CONNECTION WITH THIS AGREEMENT THE PRODUCT FOR MORE THAN FOURTEEN 14 DAYS AFTER RECEIPT IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT YOU MAY RETURN THE PRODUCT TO COMPANY WITHIN FOURTEEN 14 DAYS OF RECEIPT AT NO COST TO YOU 1 RESOLUTION OF CLAIMS OR DISPUTES Any claim or dispute between you and Company or any of Company s subsidiaries or affiliates arising out of or relating in any way to the Product or this Agreement shall be resolved through final binding arbitration This arbitration obligation applies regardless of whether the claim or dispute involves a tort fraud misrepresentation product liability negligence violation of a statute or any other legal theory Both you and Company specifically acknowledge and agree that you waive your right to bring a lawsuit based on such claims or disputes and to have such lawsuit resolved by a judge or jury 2 LIMITATION OF LEGAL REMEDIES All arbitrations under this Agreement shall be conducted on an individual and not a class wide basis and an arbitrator shall have no authority to award class wide relief You acknowledge and agree that this Agreement specifically prohibits you from commenci
6. expenses b if the claim or dispute that is the subject of the arbitration proceedings is more than ten thousand dollars US 10 000 but less than seventy five thousand dollars US 75 000 you will be responsible for no more than three hundred seventy five dollars US 375 in administrative expenses and c if the claim or dispute that is the subject of the arbitration proceedings is more than seventy five thousand dollars US 75 000 then you will be responsible for administrative expenses in accordance with the Commercial Fee Schedule provided by the AAA You acknowledge and agree that each party shall pay the fees and costs of its own counsel experts and witnesses 4 CHOICE OF LAW This Agreement shall be governed by the United States Federal Arbitration Act and the laws of the State of California 5 SEVERABILITY If any provision of this Agreement is declared or found to be unlawful unenforceable or void such provision will be ineffective only to the extent that it is found unlawful unenforceable or void and the remainder of the provision and all other provisions shall remain fully enforceable UV LAMP REPLACEMENT SCHEDULE We recommend that you replace the UV lamp on an annual basis UV lamp replaced on Purchased at UV lamp replaced on Purchased at UV lamp replaced on Purchased at UV lamp replaced on Purchased at UV lamp replaced on __ CS Purchased at UV lamp replaced on CS Pu
7. ganic compounds from the air including toxic fumes and chemicals such as paint and new carpet fumes Effectively removes smoke pollen dust animal dander dust mites mold and bacteria gt 3 speed fan setting lets you select the desired cleaning level MAIN PARTS Ww OC anayes Permanent HEPA Type Filter the permanent filter removes small visible and non visible particles down to 0 1 microns in size 3 Speed Settings there are 3 speed settings low medium and high for you to choose according to the air quality needs in the room UV Lamp Button the germicidal UV light is used to kill harmful airborne bacteria germs and viruses Locking Latch Air Inlet Grill Air Outlet Grill UV Lamp View Window Base of Unit UV Lamp Access 4 Locking Latch 1 Permanent HEPA Type Filter 5 Air Inlet Grill 3 UV Lamp Button 2 Control Panel 6 Air Outlet Grill 7 UV Lamp View Window 9 UV Lamp Access 101M OPERATING THE THERAPURE 101M Before using your Therapure 101 air purifier please read the following important information Electrical Ratings 120V Setting 120Vac 60 Hz Power consumption 38 watts at high fan speed 3 watt UV light bulb Net weight 6 5 lbs Dimension LxWxH 10 x 7 5 x 16 Replacement Parts Lamp TPP1010 Filter TPPion OPERATING THE THERAPURE 101M
8. k to ensure unit is plugged in Check to mke sure filters are properly installed amp locked into place Check to make sure the cover is properly installed and locked into place Check to ensure nothing is blocking air inlet amp air outlet Check amp clean filter if necessary Check that the UV button is turned on Replace the UV lamp ONE YEAR LIMITED WARRANTY ONE YEAR LIMITED WARRANT Y Your Therapure 101 air purifier is warranted to be free from defects in materials and workmanship for one year from the original purchase date excluding the lamp Should the product have a defect in materials or workmanship we will repair or replace it without charge to you a shipping and processing fee may apply To obtain service under warranty simply call our Customer Service Center toll free at 1 800 554 6168 This warranty does not cover any damage caused by accident misuse or any use other than as intended and described in this owner s guide or damage resulting from failure to maintain and clean this product as specified in this product manual This warranty applies only to the original purchaser of the Therapure 101 air purifier Contact Info for Warranty Service lonic Pro P O Box 4135 Hollywood CA 90028 1 800 554 6168 www therapureair com 2007 2008 lonic Pro LLC All Rights Reserved thera pure ARGITRATION AGREEMENT THIS ARBITRATION AGREEMENT AGREEMENT AFFECTS YOUR LEGAL RIGH
9. lug in any way gt Always turn off all controls before unplugging the Therapure 101 air purifier from outlet gt Attempting to service the Therapure 101 air purifier in any way that is not described in this owner s manual will cause the warranty to be voided and could cause serious personal injury to the user and or result in considerable damage to the unit gt Do not place the cord near a heated surface gt Never operate the Therapure 101 air purifier if the plug or cord is damaged or appears damaged Only qualified service personnel should ever replace or attempt to replace a damaged power cord gt Never use the power cord to pick up carry drag pull or lift the Therapure 101 air purifier Do not pull the cord against or around sharp corners and edges This could result in injury to the user or damage to the cord gt Always remove the plug from its power outlet by holding onto the plug itself and pulling gently gt Never pull on the cord itself to unplug it from its power outlet gt Use care when operating the Therapure 101 air purifier by keeping all foreign objects fingers body parts hair loose clothing and jewelry away from openings gt Never touch the Therapure 101 air purifier or its plug when your hands are wet gt The Therapure 101 air purifier is an electrical appliance Adult supervision is required when operating the Therapure 101 in the presence of children gt
10. ly snaps i into place Turn the base clockwise to lock it in or a slightly damp cloth x 6 Replace the cover rotate cover clockwise and the screw UV lamp The lifetime of the UV lamp is up to 18 months of continuous effective operation After this time the bulb may remain illuminated but its effectiveness is greatly reduced For maximum germicidal protection please replace the UV bulb annually If the lamp stops functioning please call 1 800 875 8577 to order a replacement lamp Cleaning External Surfaces 1 Turn off and unplug unit 2 Usea washcloth slightly dampened with a little water and dishwashing soap to wipe the outer case surfaces 3 Do not allow water to slip into the internal parts as this could damage your unit and result in electrical shock and injury to you 4 Allow the unit to thoroughly dry before use 101M TROUGLESHOOTING PROBLEM Unit will not operate Reduced airflow or poor filtering No visible light in the UV light view window REASON Speed Knob has not been turned on Unit is unplugged The inlet grill has not been installed amp locked into place The UV lamp cover has not been installed or locked in place The inlet or outlet grill may be blocked Permanent filter may be clogged UV button is not turned on UV lamp is broken SOLUTION Turn on Speed Knob Chec
11. ng arbitration proceedings as a representative of others or joining in any arbitration proceedings brought by any other person 3 ARBITRATION PROCEDURES a Before commencing any arbitration proceedings under this Agreement you must first present the claim or dispute to Company by calling 818 217 2500 and asking for the Legal Department and allowing Company the opportunity to resolve the claim or dispute If your claim or dispute is not resolved within sixty 60 days you may commence arbitration proceedings in accordance with the terms of this Agreement b The arbitration of any claim or dispute under this Agreement shall be conducted pursuant to the American Arbitration Association s AAA United States Commercial Dispute Resolution Procedures and Supplementary Procedures for Consumer Related Disputes These rules and procedures are available by calling the AAA or by visiting its web site at www adr org c The arbitration of any claim or dispute under this Agreement shall be conducted in the State of California or the location in which you received this Agreement d All administrative expenses of arbitration proceedings commenced under this Agreement shall be divided equally between you and Company except that a if the claim or dispute that is the subject of the arbitration proceedings is less than ten thousand dollars US 10 000 you will be responsible for no more than one hundred twenty five dollars US 125 in administrative
12. ns should always be used when operating this or any electrical appliance Decrease the risk of electrocution electric shock injury or fire by reading and following all the warnings below Use only as described in this Therapure manual To reduce the risk of electric shock do not attempt to service the product in any way other than in the manner described in the Cleaning amp Maintenance section of this manual READ ALL INSTRUCTIONS BEFORE OPERATING THE AIR PURIFIER gt This product operates at 120VAC 60Hz only Do not run power cord under carpets and do not cover with throw rugs gt Do not operate the product in any greasy environment such as in the kitchen This product is not intended to filter oil or grease from air gt Do not use the Therapure 101 air purifier in bathrooms or other humid environments near fireplaces or in areas where flammable or combustible vapors or products may exist gt Always unplug the power cord from electrical socket when the purifier is not in use before cleaning inserting or removing parts or before moving to another location gt Never run air purifier unless it is fully assembled gt To reduce the risk of electric shock this product has a polarized plug one blade is wider than the other This plug will fit into a polarized outlet only one way If the plug does not fit into the outlet contact qualified service personnel to install the proper outlet Do not alter the p
13. rchased at UV lamp replaced on __ e Purchased at NOTES NOTES
14. ttings are LOW MED and HI Turn the Speed Knob to rotate through the settings and select the setting you desire Keep your Therapure 101 functioning properly by cleaning the Permanent HEPA type Filter More frequent cleaning will be necessary if the unit is located in an area with a high level of airborne Your Therapure 101 air purifier has triple action purification First the Permanent HEPA type Filter contaminants excessive amounts of smoke pet dander etc removes pollutants such as dust pollen smoke and pet dander from the air Second the powerful UV technology kills airborne germs bacteria viruses mold and mildew Third the photo catalyst Exposing your Therapure to candle oil fireplace soot and smoke is not recommended and will filter removes odors and toxic chemicals and fumes require more frequent cleaning Remember Always make sure your air purifier is turned off and unplugged before cleaning Cleaning the Permanent HEPA type Filter a Clean the Permanent HEPA type Filter after each month of use b Be sure to turn off and unplug the unit before cleaning 1 Release the inlet grill by pressing on the Locking Latch see diagram of Main Parts 2 Remove the inlet grill from the unit as shown below 3 Grasp the left and right frames of the Permanent HEPA type Filter through the indentations on the sides of the filter enclosure and remove the filter 4 Toclean the Permanent HEPA type Filter use the brush attachment