Invacare IRC1175 User's Manual

image

Contents

1. 1 The wall outlet using the Freeway Freedom AC DC power pack 2 Freeway Freedom battery pack 3 A I2 volt DC source such as a car or boat DO NOT plug or unplug the 12 volt lead or AC DC power pack into the DC inlet when the ON OFF switch is in the ON 1 position otherwise damage or injury may occur OPERATION OPERATION FROM THE WALL OUTLET The Freeway Freedom power pack is required for running the Freeway Freedom from AC wall outlets and to recharge the batteries when not in use Your AC DC power pack and cord are designed to operate from U S and North American outlet voltages and plug configurations 90 240 VAC 50 60Hz By purchasing travel plug adaptors the Freeway Freedom can be utilized around the world Ensure that the ON OFF switch is in the OFF position 2 Connect the Freeway Freedom AC DC power pack to the power cord 3 Plug the power cord into the wall and the power pack outlet lead into the Freeway Freedom DC inlet The GREEN charging indicator light will come ON 4 Proceed to PREPARING FOR TREATMENT section in this manual OPERATING FROM THE FREEWAY FREEDOM BATTERY PACK Ensure the AC DC power pack or 12 volt lead is NOT plugged into the control unit panel of the Freeway Freedom 2 Ensure that the ON OFF switch is in the OFF O position 3 Insert the charged Freeway Freedom battery pack into the unit Refer to INSTALLING THE FREEW AY FREEDO
2. Check coiled duratube for blockage If blocked replace with new one DO NOT immerse in water Follow Discharge Charge directions in Prolonging the Life of your Battery Refer to MAINTENANCE Section in this Manual Procedure may need to be repeated Unit runs and Sidestream Thoroughly clean the nebulizer nebulizer makes poor or no mist Refer to AFTER THE TREATMENT section in this manual Replace nebulizer with a new one NOTE If any of the above problems occur and the solutions do not work please contact your Invacare Dealer for service 21 LIMITED WARRANTY LIMITED WARRANTY PLEASE NOTE THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4 1975 This warranty is extended only to the original purchaser user of our products This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state Invacare warrants the compressor of the Freeway Freedom Aerosol Compressor to be free from defects in materials and workmanship for a period of one 1 year from date of purchase The nebulizer mouthpiece batteries and any other accessories are excluded in this warranty If within such warranty period any such product shall be proven to Invacare s satisfaction to be defective product shall be repaired or replaced at Invacare Respiratory Corporation option This warranty does not include normal wea
3. Depth 4 5 inches 7 5 inches w accessory bag Weight 3 4 Ibs 5 2 Ibs w all accessories Battery Pack Dimensions 3 75 x 1 4 x 2 4 inches IMPORTANT DC Inlet Polarity External Positive amp Internal Negative Weights given include the l l Ib removable battery Stands for Direct Current INTRODUCTION TRAVELING INFORMATION INTRODUCTION Freeway Freedom is different than other aerosol compressors because it is smaller lighter and quieter It has the added benefit of having batteries for complete portability Carefully unpack your Freeway Freedom Keep the box as this may be required when returning it for servicing 2 The battery pack will need to be charged before use Refer to INITIAL BATTERY CHARGING in the OPERATION section of this manual 3 The Sidestream nebulizer must be boiled in water before the first use Refer to CLEANING THE SIDESTREAM NEBULIZER in the MAINTENANCE section of this manual 4 Read these instructions completely before use Observe recommendations for maintenance and replacement TRAVELING INFORMATION NOTE The Freeway Freedom Aerosol Compressor uses nickel metal hydride batteries which are accepted for use on most airlines However we strongly advise that you contact your airline before travel to ensure their approval The AC DC Power Pack and cord are designed to operate from U S and North American outlet voltages and plug configurations 90 240
4. Rinse out the Sidestream nebulizer and refill with a little clean water Reconnect the coiled duratube to the Sidestream nebulizer and run the Freeway Freedom again for a few seconds in order to flush out any of the medication that has become trapped in the nebulizer jets Turn OFF O the Freeway Freedom and disconnect the Sidestream nebulizer from the coiled duratube by gently twisting the tubing Run your Freeway Freedom for approximately 15 seconds without the Sidestream nebulizer connected to dry out any condensation in the coiled duratube When cleaning the Sidestream nebulizer medication chamber take great care not to damage the jet holes DO NOT use a cleaning brush abrasive sponge or pad as this damages the center baffle and seriously affects the performance of the Sidestream nebulizer NEVER put paper clips needles or any other objects into the jet holes NEVER put the coiled duratube in any liquid 6 Disassemble the Sidestream nebulizer into three 3 pieces the base the center baffle and the top as shown in FIGURE 3 Wash Sidestream nebulizer and mask or mouthpiece in warm soapy water rinse thoroughly and air dry NOTE Electrical items and any other dry components may be stored in the detachable accessory bag 7 When all parts are thoroughly dry store them in the storage compartment on the top of the Freeway Freedom ONLY NEVER store your nebulizer and medication in any other area except the stor
5. 16 hours and discharged several times to regain full capacity Storing an extra battery completely discharged may cause permanent damage to the battery 3 Operate your Freeway Freedom from the AC DC power pack or from a 12 volt DC source whenever possible 4 Avoid exposure to extreme temperatures DO NOT operate the unit or charge the batteries in temperatures above 104 40 C or below 50 F 10 C or place near heat sources such as radiators or fires DO NOT dispose of the battery pack in the household waste at the end of its useful life approx 2000 treatments Proper disposal at an appropriate collection site provided in your local area is strongly recommended CLEANING THE FREEWAY FREEDOM UNPLUG unit before cleaning DO NOT submerge in water to clean NEVER put the coiled duratube in any liquid Electrical shock hazard DO NOT remove outer case of this unit All disassembly and maintenance of this unit MUST BE done by a qualified technician DO NOT wipe the air filter or battery terminals 18 MAINTENANCE Your Freeway Freedom battery pack and power pack can be cleaned by wiping with a damp cloth The carrying case can be machine washed 40 Tumble dry at low temperature settings CLEANING THE SIDESTREAM NEBULIZER NOTE Refer to AFTER THE TREATMENT in the OPERATING section of this manual for regular use cleaning instructions Initially and once each week your Sidestream nebulizer sh
6. VAC 50 60Hz By purchasing travel plug adaptors the Freeway Freedom can be utilized around the world THE FREEWAY FREEDOM BATTERY PACK THE FREEWAY FREEDOM BATTERY PACK The Freeway Freedom battery pack contains nickel metal hydride NiMH cells Refer to PROLONGING THE LIFE OF THE BATTERY in the MAINTENANCE section of this manual A second battery pack may be purchased for emergency purposes or if extra power is required for more treatments e g on a long airplane flight between charges INSTALLING THE FREEWAY FREEDOM BATTERY PACK FIGURE 1 Remove the protective film covers plastic tape from the battery terminals before installing the Freeway Freedom battery pack 2 Install the Freeway Freedom battery pack into the bottom of the Freeway Freedom as shown in FIGURE REAR VIEW E j Freeway Freedom j i Od Freeway CM t Freedom q L Battery Pack FIGURE INSTALLING THE FREEWAY FREEDOM BATTERY PACK THE FREEWAY FREEDOM BATTERY PACK INITIAL BATTERY CHARGING To maximize the capacity and life of the Freeway Freedom rechargeable batteries FULLY charge them for 16 hours before initial use FULLY discharge the batteries by running the unit 20 minutes ON 1 then 40 minutes OFF O until the unit no longer runs Repeat cycle two 2 to three 3 times M Next FULLY charge the batteries for 16 hours Now the unit is ready for regular use with the batteries NOT
7. all accessories are changed at least once a year especially the Sidestream nebulizer and the coiled duratube if your Freeway Freedom is being used three 3 or more times a day The air filter should be replaced every three 3 months Refer to REPLACING THE AIR FILTER in the MAINTENANCE section of this manual for replacement procedure If you cannot solve a problem or would like to order any spare parts please contact your Invacare Dealer ACCESSORIES AND SPARE PARTS 1114879 AC DC Power Pack 1114883 Freeway Freedom Battery Pack 1114885 Replacement Filters Qty 4 1114882 I2V DC Lead Car Adapter 1114880 Carrying Case and Detachable Case 1110518 Owner s Manual 2001829 Coiled Duratube Tubing 2001831 Power Cord MS2400 Reusable Sidestream Nebulizer 20 TROUBLESHOOTING TROUBLESHOOTING PROBLEM POSSIBLE SOLUTIONS Unit does not run from battery Assure battery is installed properly Remove Protective film tape Check all leads are removed from DC inlet Charge battery for 16 hours Unit does not charge and Confirm power pack is plugged GREEN Charging indicator is into live wall outlet NOT illuminated Have Freeway Freedom serviced by your Dealer Unit does not run from DC inlet Check fuse in DC cigarette lighter lead 2 Check for correct polarity Refer to SPECIFICATIONS Section in this manual Unit runs slowly or battery Check if filter is clean Replace usage time decreased
8. registered trademarks of the Profile Therapeutics plc group of companies Yes you can is a trademark of Invacare Corporation 2002 Invacare Corporation Part No 1110518 Rev A 08 02 UK Part No RP3753 Issue Manufactured by Profile Therapeutics plc Heath Place Bognor Regis West Sussex P022 9SL UK www profiletherapeutics com
9. E Refer to NORMAL BATTERY CHARGING PROCEDURES in this manual for charging procedures NORMAL BATTERY CHARGING PROCEDURES The Freeway Freedom internal control circuit regulates the battery charging The Freeway Freedom battery pack can be charged for as long as you require without damage It will take approximately 16 hours to recharge a fully discharged battery NOTE A FULLY charged battery should provide approximately 36 minutes of treatment time between charges Ensure that the ON OFF switch is in the OFF O position 2 not already installed attach the battery pack to the Freeway Freedom Refer to INSTALLING THE FREEWAY FREEDOM BATTERY PACK section in this manual Your power supply at the DC inlet MUST BE the correct polarity Refer to SPECIFICATIONS in this manual The Freeway Freedom will NOT charge batteries from an incorrect polarity DC supply 199 Connect the AC DC power pack or 12 volt DC lead to the DC power inlet on the Freeway Freedom and connect the other end to a suitable power supply wall or car outlet The GREEN Charging indicator light will come ON to show that the unit is charging 10 OPERATION OPERATION EXPLANATION OF POWER INDICATOR LIGHTS POWER INDICATOR LIGHTS GREEN ON Operating Light s YELLOW Low Power Light 4 GREEN Charging Indicator ae POWER SUPPLY OPTIONS Freeway Freedom may be operated from three 3 different sources
10. EATURES FEATURES f Child Mask Mouthpiece 7 Coiled Duratube Sidestream Nebulizer NOTE There is a medication pocket and an identification tag on the inside flap of the carrying case Your nebulizer mask or mouthpiece may be stored in the storage compartment Storage Compartment Air Filter Cover redd Detachable Accessory Bag Battery Pack Installed Power Indicator 12V DC Input Lights Plug AC DC x Power Pack a NOTE The 12 volt DC lead AC DC power pack and power cord may be stored in the detachable accessory bag 12 volt DC lead 6 SPECIFICATIONS MODEL IRCI 175 SPECIFICATIONS Electrical Requirements 90 240 VAC 50 60 Hz or 12 14 VDC Ambient Temperature Range 10 C 40 C 50 F 104 F NOTE Operating at extreme temperatures may increase treatment times Power Wattage 24 Watts II 1 PSI Thermal Protector Internal Solid State Auto Resettable NOTE The Freeway Freedom unit and Battery Pack each have an internal resettable thermal fuse in case of overheating operating longer than 20 minutes or using incorrect polarity DC jack Safety Systems Class II Double Insulated 1 Fuse T3 Amp Fuse Intake Filter 300 micron polyethylene Flowrate Flowrate typical 6 Ipm with Sidestream nebulizer model MS2400 back pressure approximately 9 5 5 PSI Width 9 25 inches Height 6 5 inches
11. M BATTERY PACK section in this manual 4 Proceed to the PREPARING FOR TREATMENT section in this manual OPERATING FROM A CAR OR A BOAT The Freeway Freedom s 12 volt lead will fit into the majority of car cigarette lighter sockets The vehicle MUST BE a negative ground system This is normal on practically all modern vehicles Connection to a positive ground system cannot damage the Freeway Freedom the unit simply will NOT operate or charge the battery from an incorrect polarity DC supply OPERATION If the unit does NOT operate IMMEDIATELY disconnect the power supply from the DC inlet and check for correct polarity Refer to SPECIFICATIONS in this manual NOTE Battery alligator clips can be purchased from an electronics retail supply company These connect the cigarette lighter plug of the DC lead directly to a 12 volt DC battery instead of using a cigarette lighter Ensure that the ON OFF switch is in the OFF O position 2 Plug the I2 volt DC lead into the DC inlet 3 Connect the I2 volt DC lead to the power supply The GREEN Charging indicator light will now come ON 4 Proceed to the PREPARING FOR TREATMENT section in this manual PREPARING FOR TREATMENT FIGURE 2 The nebulizer kit contains all the accessories that you need for your treatment DO NOT begin a treatment when YELLOW LOW POWER light 1 4 is illuminated Charge the battery or use another power source NO
12. OPERATOR S MANUAL INVACARE FREEWAY FREEDOM AEROSOL COMPRESSOR MODEL IRCI175 DEALER THIS MANUAL MUST BE GIVEN TO THE END USER USER BEFORE USING THIS COMPRESSOR READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE SPECIAL NOTES SPECIAL NOTES DANGER WARNING CAUTION notices as used in this manual apply to hazards or unsafe practices which could result in personal injury or property damage NOTICE THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE THIS AEROSOL COMPRESSOR IS INTENDED FOR HOUSEHOLD USE DO NOT install maintain or operate this equipment without first reading and understanding this manual If you are unable to understand the DANGERS WARNINGS CAUTIONS and INSTRUCTIONS contact a healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may result SAVE THESE INSTRUCTIONS 2 TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES TABLE OF CONTENTS SAFETY SUMMARY FEATURES SPECIFICATIONS INTRODUCTION TRAVELING INFORMATION THE FREEWAY FREEDOM BATTERY PACK Installing the Freeway Freedom Battery 9 Initial Battery Charging eerte tentent 10 Normal Battery Charging Procedures sse 10 OPERATION Explanation of Power Indicator Lights sss 11 Power Supp
13. RODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE S CONTROL AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE FOLLOWING INSTRUCTIONS THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER WHETHER EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PERSUANT TO THE TERMS CONTAINED HEREIN THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE PROVINCIAL LAWS AND REQUIREMENTS 23 gee INVACARE Yes you can Invacare Corporation www invacare com USA One Invacare Way Elyria Ohio USA 44036 2125 800 333 6900 699 Aero Lane Sanford Florida 32771 Technical Support Toll Free 800 832 4707 Invacare is a registered trademark of Invacare Corporation Freeway and Sidestream are
14. TE The Freeway Freedom has been designed to be used with the Sidestream Nebulizer Treatment times will increase if nebulizing antibiotics or using a different nebulizer Place the nebulizer in the nebulizer holder tab provided while filling with medication or when resting during treatment DO NOT fill the Sidestream nebulizer near the control panel Spilled liquid may damage the unit 2 Dispense your prescribed medication either directly into the top of the Sidestream nebulizer or into the base by unscrewing the chamber Refer to nebulizer instructions 13 OPERATION 3 Connect the long hose end of the coiled duratube to the inlet on the bottom of the Sidestream nebulizer 4 Connect either the mouthpiece supplied or face mask supplied to the Sidestream nebulizer NOTE Freeway Freedom is designed to nebulize 2 5 5cc of medication 3 to 4 times each day Child Mask Adult Mask Mouthpiece Sidestream Nebulizer Coiled Duratube FIGURE 2 PREPARING FOR TREATMENT OPERATION TAKING THE TREATMENT DO NOT use the Freeway Freedom for more than 20 minutes continuously in any one 1 hour Allow a minimum of 40 minutes rest cooling time DO NOT operate the unit in temperatures above 104 40 C or below 50 F 10 or place near heat sources such as radiators or fires DO NOT run the Freeway Freedom without an air filter as it may cause permanent damage to the compressor Turn the Freeway Freed
15. TO REDUCE THE RISK OF ELECTROCUTION Always unplug this product IMMEDIATELY after using DO NOT use while bathing DO NOT place or store product where it can fall or be pulled into a tub or sink DO NOT reach for product that has fallen into water UNPLUG IMMEDIATELY DO NOT place in or drop into water or liquid TO REDUCE THE RISK OF BURNS ELECTROCUTION FIRE OR INJURY TO PERSONS Close supervision is necessary when this product is used by on or near CHILDREN OR PHYSICALLY CHALLENGED INDIVIDUALS SAFETY SUMMARY DO NOT operate unit longer than twenty 20 minutes CONTINUOUSLY Allow forty 40 minutes for the unit to cool before operating again Use this product only for its intended use as described in this manual Use this product ONLY under a physician s direction DO NOT use attachments NOT recommended by the manufacturer NEVER operate this aerosol compressor if it has a damaged cord or plug if itis NOT working properly if it has been dropped or damaged or dropped into water call a qualified technician for examination and repair Keep the cord away from HEATED or HOT surfaces NEVER drop or insert any object into any opening NEVER use while sleeping or drowsy DO NOT operate where aerosol spray products are being used or where oxygen is being administered in a closed environment such as an oxygen tent This unit is oil less DO NOT lubricate DO NOT operate in the rain or other wet environments F
16. age section of the carrying case Liquid medication may seriously damage the compressor 16 OPERATION MAINTENANCE Mouthpiece Sidestream Nebulizer FIGURE 3 AFTER THE TREATMENT MAINTENANCE PROLONGING THE LIFE OF YOUR BATTERY The Freeway Freedom s battery is fully sealed and requires no maintenance It should last for approximately 2000 treatments with normal use but may last even longer if you follow these rules Fully discharge the battery at least once a month and fully charge again This is accomplished by running the Freeway Freedom from the battery until it stops working approximately 10 to 12 minutes after the YELLOW LOW POWER light 41 illuminates After the unit is completely discharged use the AC DC power pack to fully charge the battery pack approximately 16 hours 2 Keep the battery connected to the Freeway Freedom and fully charged at all times If you own more than one 1 battery pack ensure that it is stored fully charged It will slowly discharge and after two 2 three 3 months will be completely discharged 17 MAINTENANCE NOTE If you are not using the Freeway Freedom for periods longer than one 1 month remove the battery pack from the device and store separately The battery pack will slowly lose charge and dependant upon storage temperature will be fully discharged after 2 3 months of storage Once fully discharged the batteries will need to be fully charged ie for
17. ly Options 11 Operation from the Wall Outlet seen 12 Operating from the Freeway Freedom Battery 12 Operating from a or a Boat seen 12 Preparing for Treatment eerte tete tnttntentns 13 Taking the Treatment tette tercia 15 After the Treatment siente nete Erit pede Ecrit l6 MAINTENANCE Prolonging the Life of your Battery see 17 Cleaning the Freeway Freedom seen 18 Cleaning the Sidestream Nebulizer see I9 Replacing the Air Filter eene 19 Fuse 20 Nase RR 20 Accessories and Spare Parts csssssssssessssssssssssessssssssssesseseessensseseess 20 TROUBLESHOOTING LIMITED WARRANTY SAFETY SUMMARY SAFETY SUMMARY Caution Federal law restricts this device to sale or rental by or on order of a physician or any other practitioner licensed by the law of the state in which he practices to use or order the use of this device Risk of electric shock DO NOT disassemble Refer servicing to qualified service personnel READ THE FOLLOWING INFORMATION BEFORE OPERATING THIS PRODUCT When using electrical products especially when children are present basic safety precautions should always be followed including the following
18. om power switch to the ON I position and the Sidestream nebulizer will produce a fine mist NOTE If the Freeway Freedom does NOT operate correctly refer to the TROUBLESHOOTING section of this manual 2 It is suggested that you are as relaxed as possible and are sitting in an upright position to obtain the maximum benefit from the treatment 3 It is suggested that two 2 or three 3 deeper breaths are interspersed with gentle lower chest breathing NOTE If you get breathless during treatment you are probably breathing too quickly If you want to take a short break during treatment switch OFF O the Freeway Freedom and resume treatment after your break NOTE During use the Freeway Freedom s battery is prevented from being discharged to a level that would cause permanent damage If the YELLOW LOW POWER light 1 4 comes ON during treatment finish the treatment This normally indicates that between 20 to 50 of the operating time is left This actual time will vary with each unit and the light will illuminate earlier as the batteries age 4 When the Sidestream nebulizer begins to work intermittently and spits then the treatment has finished There is no need to nebulize every drop of your medication as there will always be a small amount left in the chamber 15 OPERATION AFTER THE TREATMENT FIGURE 3 M A m Disconnect the Sidestream nebulizer from the coiled duratube by gently twisting the tubing
19. ould be boiled in water with two 2 drops of dish washing liquid for 5 to 10 minutes REPLACING THE AIR FILTER FIGURE 4 The air filter cleans the air that you use during treatment The air filter gets dirty over time and will need to be replaced As soon as the air fileer no longer looks white and clean approximately 3 months it should be changed NOTE The air filter will need to be changed more regularly if used in an environment with excessive dirt or smoke Remove the air filter cover and the dirty air filter 2 Insert a clean air filter and replace the air filter cover 3 Dispose of dirty air filter Air Filter Cover FIGURE 4 REPLACING THE AIR FILTER 19 MAINTENANCE FUSE REPLACEMENT The 12 volt DC lead cigarette lighter lead is fitted with a T3 amp fuse This is located in the cigarette lighter plug and is removed by unscrewing the end of the cigarette lighter plug body Replacement fuses can be purchased at your local electronics store NOTE The Freeway Freedom battery pack and power pack are internally fused and cannot be serviced If you suspect a fault contact your local Invacare Dealer for service NOTE The Freeway Freedom is fitted with an auto resetting solid state PCB fuse This fuse does NOT require service SERVICING Invacare recommends that the Freeway Freedom is serviced by a qualified technician at least once a year Accessories should be replaced regularly It is recommended that
20. r and tear or shipping charges incurred in replacement part installation or repair of such product Invacare s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and or replacement For warranty service please contact Invacare s Service Department at the Toll Free Number listed Back Cover during normal hours Upon receiving notice of an alleged defect in a product Invacare will issue a serialized return authorization It shall be the responsibility of the purchaser to return at the purchaser s cost to either Invacare s plant or service center as specified by Invacare in advance Defective components part s must be returned for warranty inspection using the serial number for identification within 30 days of the return authorization date DO NOT return products to our factory without prior consent C O D shipments will be refused please prepay shipping charges 22 LIMITED WARRANTY LIMITATIONS AND EXCLUSIONS THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED PRODUCTS SUBJECTED TO NEGLIGENCE ACCIDENT IMPROPER OPERATION MAINTENANCE OR STORAGE PRODUCTS MODIFIED WITHOUT INVACARE S EXPRESS WRITTEN CONSENT INCLUDING BUT NOT LIMITED TO MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE OR TO A P