1. PID Interrupt PCI Interrupt Component PCI Slot PCI Bus 0 D P10 PCI D 1 C P10 PCI D 2 B Onboard SCSI Channel B PCI A 3 B P10 PCI D 4 LA P10 PCI D 5 D P9 PCI D 6 c P9 PCI D 7 B P9 PCI D 8 A P9 PCI D 9 D P8 PCI C 10 c P8 PCI C 11 B P8 PCI C 12 A P8 PCI C 13 D P7 PCI C 14 c P7 PCI C 15 B P7 PCI C 16 A P7 PCI C 17 D P6 PCI B 18 C P6 PCI B 19 B P6 PCI B 20 A P6 PCI B 21 D P5 PCI B 22 C P5 PCI B 23 B P5 PCI B 24 A P5 PCI B 25 D P4 PCI B 26 C P4 PCI B 27 B P4 PCI B 28 A P4 PCI B 29 D P3 PCI B 30 Es P3 PCI B 31 B P3 PCI B 32 A Video PCI A 33 D PIIX4e PCI A 34 A P3 PCI B 35 D P2 PCI A 36 ES P2 PCI A 37 B P2 PCI A 38 A P2 PCI A 39 D Pi PCI A 40 c PI PCI A 41 B Pi PCI A 42 A Onboard SCSI Channel A PCI A 43 PCI Hotplug Interrupt P1 P10 AII 44 SCBERR MAC 45 A P1 PC 46 NMI PIIX4e G 47 nused 188 Technical Reference Video Modes The CL GD5480 integrated video controller provides all standard IBM VGA modes With 8 MB of SDRAM standard The ATI Rage XI supports all the standard VGA XVGA SVGA modes with a maximum resolution of 1600 x 1200 at 85 Hz See the A
2. Io mn mMm OM08781 Figure 3 Chassis Back View PCI add in board expansion slots External LVDS connector PS 2t compatible keyboard mouse port 6 pin PS 2 compatible keyboard mouse port 6 pin PS 2 compatible serial ports A and B 9 pin RS 232 connector Super VGA compatible 15 pin video connector PS 2 compatible parallel port LPT 25 pin bidirectional subminiature D connector USB ports 0 and 1 4 pin connector Interchassis Management Bus ICMB connectors port 1 and 2 Power supplies in this view supplies must be populated from left to right the right bay would contain the redundant supply Power supply failure LED yellow Power supply predictive failure LED yellow for power supply fan Power supply power LED green AC input power connector crironmouow gt x zer SRPL8 Server System Product Guide 17 Peripherals The peripheral bay provides the interface for 3 5 inch and 5 25 inch media 3 5 inch Diskette Drive The 3 5 inch diskette drive in the peripheral bay supports 720 KB and 1 44 MB media The drive is externally accessible from the front of the system 3 5 inch Hard Drive Bays The peripheral bay contains two hot swapping bays for two 3 5 inch wide 1 0 inch high or 1 6 inch high wide f
3. Device Segment Device Number Hot Plug Controller A 00h PCI Slot 1 A 04h PCI Slot 2 A 05h Embedded LVDS A OAh Embedded VGA A OCh PIIX4e A OFh MAC A 14h PB64 A 18h PB64 A 19h PB64 A 1Ah PB64 A 1Bh Hot Plug Controller B 00h PCI Slot 3 B 04h PCI Slot 4 B 05h PCI Slot 5 B 06h PCI Slot 6 B 07h PID B 09h Hot Plug Controller C 00h PCI Slot 7 C 04h PCI Slot 8 C 05h Hot Plug Controller D 00h PCI Slot 9 D 04h PCI Slot 10 D 05h Interrupts The table below recommends the logical interrupt mapping of interrupt sources it reflects a typical configuration but these interrupts can be changed by the user Use the information to determine how to program each interrupt The actual interrupt map is defined using configuration registers in the PIIX4E and the I O controller I O Redirection Registers in the I O APIC are provided for each interrupt signal the signals define hardware interrupt signal characteristics for APIC messages sent to local APIC s gt NOTE To disable either IDE controller and reuse the interrupt If you plan to disable either IDE controller to reuse the interrupt for that controller you must physically unplug the IDE cable from the board connector IDEO if a cable is present Simply disabling the drive by configuring the SSU option does not make the interrupt available SRPL8 Server System Product Guide 187 Table 33 Interrupts
4. OM10940 Figure 56 1 0 Carrier Layout IDE and diskette connectors PHP LED switch connector USB connector I O riser board connector PCI add in board slots ten Lithium battery Configuration switch SW4G1 Server management feature connector SFC Grand connector connects to midplane SCSI A and B connectors CTIQOMMOQAD SRPL8 Server System Product Guide 173 Diskette Drive 174 Table 18 Diskette Drive Connector Pinout 33 OUOOOOUUOOOOOO Uli 34 DO0000000000000000 2 OM08030 Pin Signal Pin Signal 1 GND 18 FD DIR L 2 FD DENSEL 19 GND 3 GND 20 FD STEP L 4 NC 21 GND 5 Key 22 FD WDATA L 6 FD_DRATEO 23 GND 7 GND 24 FD WGATE L 8 FD INDEX L 25 GND 9 GND 26 FD_TRKO_L 10 FD_MTRO_L 27 FD_MSENO 11 GND 28 FD WPROT L 12 FD_DR1_L 29 GND 13 GND 30 FD RDATA L 14 FD DRO L 31 GND 15 GND 32 FD HDSEL L 16 FD_MTRI_L 33 GND 17 FD_MSENI 34 FD_DSKCHG_L Technical Reference IRMC Connector ND DOUODOOUOOUOUUO 26 BUOOOO0O00000 23 OM08032 Table 19 Intel Remote Management Card Pin Signal Description 1 SMI_L System Management Interrupt 2 I2C BACKUP SCL 3 GND Ground 4 Reserved N A 5 PWR_CNTRL_SFC_L Host
5. Signal TRST_L 12V TMS TDI 5V INTA_L INTC_L 5V RESERVED 5V RESERVED GND GND RESERVED RESET L 5V GRANT L GND RESERVED AD30 3 3V AD28 AD26 GND AD24 IDSEL 3 3V AD22 AD20 GND AD18 AD16 3 3V FRAME L GND TRDY L GND STOP _L 3 3V SDONE SBO_L GND PAR AD15 3 3V AD13 AD11 Pin A48 A49 A50 A51 A52 A53 A54 A55 A56 A57 A58 A59 A60 A61 A62 A63 A64 A65 A66 A67 A68 A69 A70 A71 A72 A73 A74 A75 A76 A77 A78 A79 A80 A81 A82 A83 A84 A85 A86 A87 A88 A89 A90 A91 A92 A93 A94 Signal GND AD9 5V KEYWAY 5V KEYWAY C BEO L 3 3V AD6 AD4 GND AD2 ADO 5V REQ64_L 5V 5V GND C BE7_L C BE5 L 5V PAR64 AD62 GND AD60 AD58 GND AD56 AD54 5V AD52 AD50 GND AD48 AD46 GND AD44 AD42 5V AD40 AD38 GND AD36 AD34 GND AD32 RESERVED GND RESERVED Pin B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32 B33 B34 B35 B36 B37 B38 B39 B40 B41 B42 B43 B44 B45 B46 B47 Signal 12V TCK GND TDO 5V 5V INTB_L INTD_L PRSNT1_L RESERVED PRSNT2_L GND GND RESERVED GND CLK GND REQ_L 5V AD31 AD29 GND AD27 AD25 3 3V C BE3_L AD23 GND AD21 AD19 3 3V AD17 C BE2 L GND IRDY_L 3 3V DEVSEL L GND LOCK _L PERR_L 3 3V SERR
6. Disable Enable Disable Enable Upper Fatal Upper Fatal Upper Upper Warning Warning Lower Lower Warning Warning Lower Fatal Lower Fatal Item Item Disable Enable Disable Enable Upper Fatal Upper Fatal Upper Upper Warning Warning Lower Lower Warning Warning Lower Fatal Lower Fatal SRPL8 Server System Product Guide 203 BIOS Setup Worksheets Worksheet 14 Main Menu System Date System Time Legacy Diskette A Disabled 360 KB 1 2 MB 720 KB 1 44 MB 1 25 MB 2 88 MB Legacy Diskette B Disabled 360 KB 1 2 MB 720 KB 1 44 MB 2 88 MB Language English Spanish Italian French German Worksheet 15 IDE Submenu Type Cylinders Auto CD ROM User 1 39 Heads Sectors Maximum Capacity MultiSector Transfer Disabled 2 4 8 16 LBA Mode Control Disabled Enabled 32 Bit I O Disabled Enabled Transfer Mode Standard Fast PIO 1 Fast PIO 2 Fast PIO 3 Fast PIO 4 Ultra DMA Disabled Mode 0 Mode 1 Mode 2 Worksheet 16 Keyboard Features Submenu Num Lock Auto On Off Key Click Disabled Enabled Keyboard autorepeat rate 30 26 7 21 8 18 5 13 3 10 6 2 Keyboard autorepeat delay Yl Vall 1 Worksheet 17 Advanced Menu Reset Configuration Data Yes No Use Multiprocessor Specification 1 1 14 Large Disk Access Mode LBA CHS
7. PCI Card Bus 00 dev 00 Host Processor Bridge PCI Card Bus 00 dev OD Multifunction Controller PCI Card Bus 00 dev 0F Ethernet Controller PCI Card Bus 00 dev 12 Multifunction Controller PCI Card Bus 00 dev 14 VGA Controller 3 To configure a device click it or select its name in the Devices section of the RCA window and press the spacebar or lt Enter gt 4 You can close the RCA window and return to the AF by clicking on the Close button Any changes made will be kept in memory for use by the RCA when it is rerun 5 Save all changes by clicking lt Save gt Saving writes your current configuration to nonvolatile storage where it will be available to the system after every reboot 6 To discard all changes close the window by clicking on the system menu the dash in the upper left corner Do not do this if you want to save changes step 5 Modifying Resources 56 You might need to modify the resources of a device to accommodate certain OSs applications and drivers You might also need to modify resources to resolve a conflict To modify the resources associated with a device 1 Highlight the device in the Devices section of the RCA window 2 Press the spacebar or lt Enter gt or double click the entry This displays the functions of the selected device along with possible choices and the resources associated with those choices Configuration Software and Utilities To make a modification 1 Hi
8. 182 Technical Reference General Procedure to Change Switch Settings DO ON Observe the safety and ESD precautions at the beginning of Chapter 5 page 93 Turn off all connected peripherals and turn off system power Remove the PCI hot plug cover You do not need to remove the I O carrier from the chassis Due to the location of the switch block an add in card populated in slot 3 may need to be removed Refer to Figure 56 on page 173 for Switch SW4G1 location In the figure the switch is located to the left and slightly below the PCI Slot number 3 on the I O board When you are looking at the actual system the board will be turned 90 degrees and the switch will be located to the right and slightly below PCI Slot number 3 on the I O board A diagram of the switch configuration is also located on the underside of the PCI hot plug cover The switch block is shown with all switches in the open or disabled position by default Move the individual switch for the desired setting Power on the system for the change to take effect Return the switch to its default position after the desired operation is complete CMOS Clear Switch 1 2 Ensure that the system is powered off Remove the PCI hot plug cover On switch SW4G1 slide or press switch number 5 to the right most position Power on the system Wait for POST to complete and for the messages NVRAM cleared by jumper and Press F2 to enter Setup to appear This a
9. Total Combined Wattage W Power System Description Calculating Power Usage B Equipment Log and Configuration Worksheets Equipment Log Use the blank equipment log provided here to record information about your system You will need some of this information when you run the SSU Item Manufacturer Name and Model Number Serial Number Date Installed System Profusion carrier VO carrier Processor speed and cache Video display Keyboard Mouse Diskette drive A Diskette drive B Tape drive CD ROM drive Hard disk drive 1 Hard disk drive 2 Hard disk drive 3 Hard disk drive 4 Hard disk drive 5 continued 197 Equipment Log continued Item Manufacturer Name and Model Number Serial Number Date Installed SCSI host adapter board 1 198 Equipment Log and Configuration Worksheets Configuration Worksheets The rest of this chapter consists of worksheets to record the settings you make when configuring the system using the SSU BIOS Setup and the QLogic SCSI Utility If default values ever need to be restored to CMOS e g after a CMOS clear you must reconfigure the system Referring to the filled in worksheets could make your task easier Circle or write in your selections or the values that are displayed onscreen SSU Worksheets Add and Remove Boards Worksheet 1 Add Remove Bo
10. 5 Remove the Mezzanine Extraction Tool Cache Hold Down from the front of the processor retention bracket 6 Insert the flange end without foam under the edge of the mezzanine board at the place marked insert extraction tool here 7 Using the grand connector as a fulcrum press down on the opposite end of the tool as it lifts the rear end of the board 8 Set the tool aside and lift on both the front edge and the rear edge of the mezzanine board to unseat it from the profusion carrier board Installing the Mezzanine Board s A CAUTION Please follow these procedures carefully The mezzanine board does not have a keying feature and can be installed incorrectly Prior to seating the mezzanine board onto the connector orient the board so that the white alignment marker on the board lower right corner is aligned with the white alignment arrow located on the profusion carrier The white number label will be on the left size of the mezzanine board Look under the board to ensure that it is properly aligned with the profusion carrier and not improperly aligned with components or processor slots Push down firmly in the middle area of the mezzanine board until it s flush with the profusion carrier SRPL8 Server System Product Guide 135 Profusion Carrier Removing and Installing Removing the Profusion Carrier See Figure 45 EAN DE a pa gt N Observe the safety and ESD precautions at the beginning of this chap
11. Label and disconnect all peripheral cables and all telecommunication lines connected to VO connectors or ports on the back of the system Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 93 Warnings and Cautions These warnings and cautions apply whenever you remove covers of the system Only a technically qualified person should integrate and configure the system WARNINGS System power on off The on off button a convex button on the front panel DOES NOT turn off the system AC power To remove power from system you must unplug the AC power cords from the wall outlet or the system Hazardous conditions power supply Hazardous voltage current and energy levels are present inside the power supply There are no user serviceable parts inside it servicing should be done by technically qualified personnel Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the system and disconnect the power cords telecommunications systems networks and modems attached to the system before opening it Otherwise personal injury or equipment damage can result AX CAUTIONS Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you do all proc
12. EMI ESD grounding clips and fingers Diivalto CAMP Assembly SCA connector SCSI hard disk drive Drive carrier handle SRPL8 Server System Product Guide 85 Installing a SCSI SCA Hard Disk Drive in a Hot Swapping Bay See Figure 18 1 Orient the carrier and drive assembly in front of the hot swapping bay guide rails so that metal fingers of the perforated metal bracket attached to the carrier are facing up Make sure that the carrier is placed correctly into the guide rails to avoid damage 2 While grasping only the drive carrier handle firmly push the assembly into the bay until the drive docks with the hot swapping backplane connector A CAUTION Do not press on the perforated metal bracket of the carrier when you push the assembly into the bay or you can damage the metal fingers of the bracket OM07527 Figure 18 Installing a Hard Disk Drive A Drive carrier latch 3 If you installed a RAID controller board run the Disk Array Controller Configuration utility supplied with the board See the manufacture s documentation provided 86 Hot Swapping Fans SCSI Hard Drives and Power Supplies Determining Drive Status Status LEDs arranged in sets of three below each of the two hot swapp
13. Main DPC Console Window The main DPC console window provides a graphical user interface GUI to access server control operations and to launch the management plug ins A menu and tool bar at the top of the GUI provide options to initiate plug ins and other support features A status bar at the bottom displays connection information like server name line status and mode Toolbar The toolbar buttons combine server control and management plug in options available from the Connect and Action Menus Connects to a selected server Disconnects from the currently connected server Powers the selected server on or off Resets the selected server IS leke SEL Opens the SEL viewer SDR Opens the SDR viewer FEU Opens the FRU viewer Opens the phonebook Opens online help E Status Bar The status bar displays at the bottom of the current window It contains the following status information Server Name Lists the name of the connected server Line Lists the type of line connection direct or modem Mode Lists mode either redirect or EMP depending on whether the EMP has control of the COM port e Line Status Gives status information on the server connection For example if a server is connected the status bar says Connected Otherwise the line is blank DPC Console Main Menu e File Exit Exits the DPC console e Connect Disconnect Disconnects the server connection Re Connect Raises the c
14. The 5 25 inch removable media bay supports one SCSI or IDE device the controller itself supports more devices but the 5 25 inch bay can contain a maximum of one device SCSI devices do not need to operate at the ultra transfer rate All drives on the bus must be Ultra 160 LVD to run at 160 MB sec The 5 10 and 20 MHz operations can coexist on the bus and each device will interact at its appropriate speed No logic termination or resistor loads are required to connect devices to the SCSI controller other than termination in the device at the end of the cable The SCSI bus is terminated on the I O carrier with active terminators IDE Controller IDE is a 16 bit interface for intelligent disk drives with ATT disk controller electronics onboard The PCVISA IDE Accelerator called PIIX4E is a multifunction device on the I O carrier that acts as a PCI based Fast IDE controller The device controls PIO and IDE DMA bus master operations Mode 4 timings Transfer rates up to 22 MB sec 33 MB sec using ultra DMA transfers Buffering for PCI IDE burst transfers Master slave IDE mode Keyboard and Mouse 28 The PS 2 compatible keyboard and mouse connectors are mounted in a single stacked housing with the mouse connector over the keyboard External to the system they appear as two connectors The user can plug in the keyboard and mouse to either connector before powering up the system BIOS detects these and configures the keyboard cont
15. e From 1 to 32 DIMMs total number of DIMMs for two memory modules e Equal number of DIMMs on each memory module except when only one DIMM is used gt NOTE When only a single memory module is installed DIMM sizes on that module may vary but when both memory modules are installed the DIMM configuration on the two modules should be identical to support memory interleaving for performance gains Depending on how the memory modules are installed the memory subsystem can operate in two different modes interleaved and single port e Interleaved mode two memory modules installed The memory modules share a common address range One memory module responds to even numbered cache lines while the other responds to odd numbered cache lines This configuration offers the highest performance because it allows the two modules to be used in a balanced fashion reducing address conflicts To operate in interleaved mode the DIMMs MUST BE INSTALLED IN PAIRS ONE ON EACH MODULE AND IN THE SAME LOCATIONS ON EACH MODULE e Single port mode one memory module installed The single memory module responds to all memory addresses The DIMMs on this single carrier need not be installed in pairs and can be installed one DIMM at a time SRPL8 Server System Product Guide 25 DIMM Installation Sequence A single carrier will support DIMM population in various configurations empty sockets included However when fewer than 16 DIMMs are installed on a m
16. wrapper Installing the Front Panel Controller Board A 106 See Figure 29 CAUTION Eu When positioning the front panel board for reinstallation be sure its switches are in the sheetmetal holes before mating its connector with the profusion carrier If the switches are not in the holes they might be damaged Observe the safety precautions warnings and cautions at the beginning of this chapter Position the front panel board over the threaded standoffs with its switches protruding through the sheetmetal holes Push the board horizontally to mate the connector with the profusion carrier connector Insert the screws you removed earlier loosely into the threaded standoffs Make sure the board is properly seated then tighten all screws firmly 8 0 inch pounds Working Inside the System Install the LCD module see LCD Module on page 102 Install the insulating material removed earlier from the front panel board Install the fan array housing see Fan Array Housing on page 101 Install the top cover see Installing the Top Cover on page 99 RN Ho ll mo vo O OM07322 Figure 29 Front Panel Controller Board Profusion carrier connector LCD data connector LCD power connector Snap on standoffs two Screws seven m ee SR
17. Remove the PCI bus hot plug cover see Removing the PCI Bus Hot Plug Cover page 97 CAUTION Some accessory option board outputs exceed Class 2 or limited power source limits and must use appropriate interconnecting cabling in accordance with the national electric code during installation 108 Working Inside the System 10 11 12 13 14 OM08752 Figure 30 Enhanced PHP Functionality on Add in Board Slots A B C D PHP LED board EPHP mechanism EPHP actuator EPHP mechanism open position Being careful not to touch the components or gold edge connectors on the add in board remove it from the protective wrapper and place it component side up on a nonconductive antistatic surface Record the serial number of the board in your equipment log see page 197 Set any jumpers or switches according to the board manufacturer s instructions If your server is not operating skip this step If your server is operating e Access the PCI hot plug utility on the CD ROM that came with your server e Use the PCI hot plug utility to power down the appropriate PCI slot Press the EPHP mechanism on the actuator C then rotate the mechanism to free the PCI board from its connector Remove the I O slot filler panel for the appropriate slot Grasp the board by the top edge or upper corners and firmly press it into an expansion slot on the PHP I O carrier see Figure 31 The tapered foot of the processor ret
18. Removing and Installing nen nnnnnnnnnnnn nennen 136 Removing the Profusion Carrier 136 Installing the Profusion CAR Ses ae il en Mn nas 136 PHP VO Carrier Removing and Installing 137 Removing the PHP I O Carrier 138 Installing the PHP I O Carra enter le 138 Contents Midplane Removing andlnstaling sacrepaa one nn nt desea ve Ri bh aaa 140 Removing the Midplane sr ee 140 Installing the Midplane L aurelio 140 Memory Modules and DIMMs Removing and Installin i 142 Removing a Memory ModuUle i 142 Installing a Memory Module wiii 142 Removing DIMMS alleate nale earn 144 InstalingiDIMMss esere leali sota dio ra a a 145 Processors Removing and l stallig rss HR 147 Removing a PIOCESSOl Zus ee er ed a enter 148 Instalimg a Processor se 149 Front Side Bus FSB Termination Board Assembly 150 Removing a Termination Board nne 150 Installing a Termination Board ee a ce ara cts 151 Replacing the Backup Battery anne ce en 152 7 Solving Problems ResetlingstheSysiem toronto nl i aN Oe ee ee ale olio Be eh enen 155 Initial System Startup LES nn ein 155 CHECKISE Ha de od 155 Running New Application Software 156 O 156 After the System Has Been Running Correctly 156 Ghecklist cout iii 156 More Problem Solving Procedures cional 157 Preparing the System for Diagnostic Testing 157 Using PGLISGNOSHE
19. Setup 33 35 system setup utility SSU 33 V VCCI notice 208 VGA monitor connector 176 SRPL8 Server System Product Guide video controller 23 27 expansion 27 memory 27 resolutions supported 27 VGA monitor connector 176 Warning components might be hot 130 152 disconnect power cords cables 94 130 dispose of lithium battery safely 152 ESD can damage product 131 no user serviceable parts power supply 94 power on off switch 93 94 130 translations English 210 French 212 German 214 Italian 216 Spanish 218 vacant power supply bay 88 worksheet adding removing boards SSU 199 Advanced menu Setup 204 boot device priority Setup 206 boot menu Setup 206 I O Device Configuration submenu Setup 205 IDE submenu Setup 204 Keyboard Features submenu Setup 204 main menu Setup 204 management subsystem SSU 202 Security menu Setup 205 server console redirection Setup 206 server menu Setup 205 system management submenu Setup 206 system sensor control SSU 202 227 228 Index
20. Through the use of a configuration file the utility might prompt you for FRU information Filtering Records From the SDR File The MASTER SDR file has all the possible SDRs for the system These records will probably need to be filtered based on the current product configuration The configuration file directs the filtering of the SDRs Updating the SDR Nonvolatile Storage Area After the utility validates the header area of the supplied SDR file it updates the SDR repository area Before programming the utility clears the SDR repository area The utility filters all tagged SDRs depending on the product configuration set in the configuration file Nontagged SDRs are automatically programmed The utility also copies all written SDRs to the SDR TMP file it contains an image of what was loaded The TMP file is also useful for debugging the server Updating FRU Nonvolatile Storage Area After the configuration is determined the utility updates the FRU nonvolatile storage area First it verifies the common header area and checksum from the specified FRU file The internal use area is read out of the specified FRU file and is programmed into the nonvolatile storage The chassis area is read out of the specified FRU file Finally it reads the product area out of the specified FRU file then the area is programmed into the FRU nonvolatile storage All areas are also written to the FRU TMP file Updating DMI FRU Nonvolatile Storage Area After
21. because you will need it later Insert the diskette into the drive and boot to it At the DOS prompt run the executable file FWUPDATE EXE The utility will display a menu screen Select Upload Flash The utility will ask for a file name Enter the name of the hex file The program will load the file and then ask if it should upload boot block Read the release notes accompanying your system to verify that a boot block upgrade is not needed If it is not press N to continue 8 The program will next ask if it should upload operational code Press Y to continue 9 Once the operational code has been updated and verified press any key to continue Then press lt ESC gt to exit the program 10 Shut the system down and remove any diskettes in the system 11 Disconnect all AC power cords from the system and wait 60 seconds 12 Reconnect the AC power cords and power up the system ADA se Installing Video Drivers After configuring the system you need to install video drivers to take full advantage of the features of the onboard ATI Rage XL SVGA video controller e The configuration software CD ROM includes video drivers for use with DOS and Windows NT Check the README TXT file on the CD ROM for information on installing these drivers e For other operating systems see your OS instructions for installing device drivers Using the QLogic SCSI Utility The QLogic SCSI utility detects the SCSI host adapters on th
22. gt 2 88 MB 3 2 Primary Master Selects IDE submenu Primary Slave Selects IDE submenu Processor Information Selects Processor Information submenu Keyboard Features Selects Keyboard Features submenu Language English US Selects the language used by BIOS French German Italian Spanish Configuration Software and Utilities IDE Submenu Default values are in bold typeface Feature Option Description Type None If Auto is selected BIOS determines the parameters CD ROM during POST IDE Removable If User is selected BIOS Setup prompts the user to fill in ATAPI Removable the drive parameters Drive types 1 through 39 are User predetermined drive types Auto Cylinders Displays the number of cylinders Heads Displays the number of read write heads Sectors Displays the number of sectors per track Maximum Capacity Displays the capacity of the drive Multisector Transfers Disabled Displays status of multisector transfers Autotyped by 2 sectors BIOS 4 sectors 8 sectors 16 sectors LBA Mode Control Disabled Displays status of Logical Block Access Autotyped by Enabled BIOS 32 bit I O Disabled Enables 32 bit IDE data transfers Enabled Transfer Mode Standard Selects the method for transferring data to from the drive Fast PIO 1 Autotyped by BIOS Fast PIO 2 Fast PIO 3 Fast PIO 4 Ultra DMA Mode Disabled Selects the Ultra DMA mode used for transferring data Mode 0 to from the
23. 20 34 GND 54 GND 35 DB12 L 55 ATNL 36 DB13_L 56 GND 37 DB14 L 57 BSY L 38 DB15 L 58 ACK_L 39 DBP1_L 59 RSTL 40 DBO_L 60 MSG_L 41 DBAL 61 SELL 42 DB2_L 62 C D_L 43 DB3_L 63 REQ L 44 DB4_L 64 VOL 45 DB5 L 65 DB8 L 46 DB6_L 66 DB9 L 67 47 DB7_L DB10_L 48 DBP _L 68 DB11_L 178 Technical Reference IDE 39 TOO OO ODOOOODOODOODDOOODDM 1 40 00000000 OOOOU OO 2 OM08029 Table 26 IDE Connector Pinout Pin Signal Pin Signal 1 RSTDRV 21 DRQ 2 GND 22 GND 3 DD7 23 DIOW 4 DD8 24 GND 5 DD6 25 DIOR 6 DD9 26 GND 7 DDS 27 IORDY 8 DD10 28 CSEL 1 KQ p d 9 DD4 29 DACK 10 DD11 30 GND 11 DD3 31 IRQ 12 DD12 32 Reserved N C 13 DD2 33 DAI 14 DD13 34 Reserved N C 15 DDI 35 DAO 16 DD14 36 DA2 17 DDO 37 CSIPL 18 DD15 38 DS3P_L 19 GND 39 DHACT L 20 Keyed 40 GND If no IDE drives are present no IDE cable should be connected If only one IDE drive is installed it must be connected at the end of the cable SRPL8 Server System Product Guide 179 PC 180 Table 27 33MHz 64 bit PCI Connectors Slots A and B Pin Al A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17
24. 3F8h 2F8h 3E8h 2E8h Selects the base I O address for COM port B IRQ3 IRQ4 Interrupt Selects the IRQ for COM port B Parallel Port Enabled Auto Disabled If set to Auto BIOS configures the port Mode Output only Bidirectional EPP ECP Selects the mode of the LPT port Base 1 0 Address 378h Selects the base I O address for LPT port 178h is only 278h available when the LPT port is in EPP mode Otherwise 178h 3BCh is available 3BCh Interrupt IRQ5 Selects the IRQ for LPT port IRQ7 DMA channel Selects the DMA channel for LPT port when configured for Floppy disk controller Disabled Enabled Auto OS Controlled SRPL8 Server System Product Guide ECP mode Enables embedded floppy disk controller 43 Advanced Chipset Control Submenu 44 Default values are in bold typeface Feature Option Description Extended RAM Step 1MB Selects the thoroughness of the extended memory test If 1 KB 1 MB is selected BIOS tests each 1 MB boundary Every location If 1KB is selected BIOS tests each 1 KB boundary If Every location is selected BIOS tests every byte BIOS defaults to the fastest test L2 Cache Disabled Enables the second level cache The second level cache Enabled should be disabled only for diagnostic purposes Multiboot Support Disabled Enables Boot Device Selection Enabled Override PHP Switches Disabled If enabled the individual slot swi
25. 4 GB The server does not support memory gaps from 512 KB to 640 KB and from 15 MB to 16 MB These regions are treated as normal system memory Table 31 Memory Map Address Range Amount Function 00000000 0009FFFF 640K Base conventional System Memory 000A0000 000AFFFF 128K ISA Video buffer 000C0000 000D7FFF 96K Add in Options ROM s Video SCSI 000C0000 000D7FFF 96K Add in Options ROM s 000D8000 OOODBFFF 16K Allocated to Run time user binary if enabled programmed otherwise can be used for options ROM s 000DC000 000DFFFF 16K Allocated to Console Redirection if enabled otherwise can be used for options ROM s 000E0000 000FFFFF 128K System BIOS Shadowed 00100000 PCI Memory Typically it can go up to 3GB allocated to first PCI device FEC00000 FECOFFFF 64K Reserved Unused on this platform Reclaimed If main memory exceeds this region FEC10000 FEC1FFFF 64K IOAPIC allocated to the PID Reclaimed If main memory exceeds this region FEC20000 FECFFFFF 896K Reserved Reclaimed If main memory exceeds this region FEE00000 FEF00000 1MB LOCAL APIC Reclaimed If main memory exceeds this region FF000000 FFDFFFFF 14MB Unused Reclaimed If main memory exceeds this region FFE00000 FFFFFFFF 2MB Main System BIOS 100000000 1FFFFFFFF 4GB If memory exists 186 Technical Reference PCI Configuration and Device Map Table 32 PCI Map
26. 42 PCI X 100 Default values are in bold typeface Feature Option ROM Scan Disabled Enabled Selects PCI Mode submenu for the embedded LVDS controller Selects PCI Mode Submenu for this PCI slot Selects PCI Mode Submenu for this PCI slot Selects PCI Mode Submenu for this PCI slot Selects PCI Mode Submenu for this PCI slot Selects PCI Mode Submenu for this PCI slot Selects PCI Mode Submenu for this PCI slot Selects PCI Mode Submenu for this PCI X slot Selects PCI Mode Submenu for this PCI X slot Selects PCI Mode Submenu for this PCI X slot Selects PCI Mode Submenu for this PCI X slot Description Enables option ROM scan Enable Master Latency Timer Disabled Enabled Default 0020h 0040h 0060h 0080h 00A0h 00C0h OOEOh Enables device s as a PCI bus master Specifies the minimum guaranteed number of PCI bus clocks that a device can master on a PCI bus during one transaction Configuration Software and Utilities I O Device Configuration Submenu Default values are in bold typeface Feature Option Description Disabled Enabled Auto Serial Port A If set to Auto BIOS configures the port Base I O Address 3F8h 2F8h 3E8h 2E8h Selects the base I O address for COM port A IRQ3 IRQ4 Interrupt Selects the IRQ for COM port A Serial Port B Enabled Auto Disabled If set to Auto BIOS configures the port Base I O Address
27. Alt Del gt Clear system memory restart POST and reload the operating system Reset button Cold boot reset which clears system memory restarts POST reloads the Power off on operating system and halts power to all peripherals Initial System Startup Problems that occur at initial system startup are usually caused by incorrect installation or configuration Hardware failure is a less frequent cause Checklist Are all cables and boards correctly connected and secured Are the processors and termination boards fully seated in their slots on the mezzanine board s Is at least one memory board installed and fully seated Are all add in PCI boards fully seated in their slots on the I O carrier Are all switch and jumper settings on boards and drives correct Are all switch and jumper settings on add in boards and peripheral devices correct To check these settings refer to the manufacturer s documentation that comes with them If applicable ensure that there are no conflicts for example two add in boards sharing the same interrupt Are all DIMMs installed correctly Are all peripheral devices installed correctly Is the hard disk drive properly formatted or configured Are all device drivers properly installed Are the configuration settings made with the SSU correct Is the OS properly loaded Refer to the OS documentation Did you press the system power on off switch on the front panel to turn the server on power
28. Boot Video Blanking Diskette Write Protect Worksheet 23 Server Menu Clear Set Clear Set Disabled Enabled Disabled lt time gt lt key stroke gt Disabled Enabled Disabled Enabled Disabled Enabled Processor Retest No Yes EMP Password Switch Disabled Enabled EMP Access Mode EMP Restricted Access Mode Preboot Only Always Active Disabled Enabled Disabled EMP Direct Connect Modem Mode SRPL8 Server System Product Guide Direct Connect Modem Mode 205 206 Worksheet 24 System Management Submenu Firmware SMIs Disabled Enabled System Event Logging Disabled Enabled Clear Event Log Disabled Enabled Assert NMI on SBE Disabled Enabled Assert NMI on AERR Disabled Enabled Assert NMI on BERR Disabled Enabled Assert NMI on PERR Disabled Enabled Assert NMI on SERR Disabled Enabled Enabled Host Bus ECC Disabled Enabled Worksheet 25 Console Redirection Submenu Disabled 3F8 2F8 3E8 COM Port Address IRQ Baud Rate Flow Control Worksheet 26 Boot Menu 3 4 9600 19 2k 38 4k 115 2k None CTS RTS XON XOFF CTS RTS CD Diskette Check Disabled Enabled Maximum No of 120 Drives 1 4 Message Timeout Multiplier Pause During Post Disabled Enabled 1 2 8 10 50 100 1000 Worksheet 27 Boot Device Priority Submenu Boot Priority 1 Bo
29. DIMMs Slot Layout SRPL8 Server System Product Guide 145 146 See Figure 50 1 2 ON E Holding the DIMM only by its edges remove it from its antistatic package Orient the DIMM so that the two notches in the bottom edge of the DIMM align with the keyed socket on the memory module Insert the bottom edge of the DIMM into the socket then press down firmly on the DIMM until it seats correctly Gently push the plastic ejector levers on the socket ends to the upright position Repeat the steps to install each DIMM Reinstall the memory module Run the SSU to configure the system and to properly attribute ECC memory OM07320 Figure 50 Installing DIMMs Upgrading Boardset Components Processors Removing and Installing The profusion carrier supports two processor mezzanine boards Each mezzanine board provides four Slot 2 connectors for Pentium III Xeon processors packaged in S E C cartridges Unpopulated Slot 2 connectors require front side bus FSB termination boards When removing and installing processors read the sections Front Side Bus FSB Termination Board Assembly on page 150 CAUTION The processors can be extremely sensitive to ESD and always require careful handling After removing a processor from a protective wrapper or from a mezzanine board place it on a nonconductive static free surface Do not slide the processor over any surface SRPL8 Server System Product Guide 147 Removing a
30. EMP in this state you can remotely view boot messages access BIOS setup and run DOS text mode applications through the DPC console s terminal window SRPL8 Server System Product Guide 63 2 g EMP Console File Connect Action Help ala ou Z7 2 SERVER NAME LINE MODE LINE STATUS 7 Figure 9 DPC Console in Command State 2g EMP Console Redirect File Connect Action Window Help ala el 51515 al 2 E Redirect PhoenixBI0S 4 6 Release 6 8 Copyright 1985 1998 Phoenix Technologies Ltd All Rights Reserv NIGHTS0 86B 0014 B 9802061855 446BX DP BIOS beta 2 FOR EVALUATION ONLY NOT FOR RESALE Build Time 02 06 98 18 39 51 CPU Pentium R II Processor 366 MHz B0090640K System RAM Passed 66664512K Extended RAM Passed 6512K Cache SRAM Passed System BIOS shadowed Video BIOS shadowed UMB upper limit segment address F192 Keyboard Detected ATAPI CD ROM HITACHI CDR 8336 SERVER NAME LINE Direct MODE Redirect LINE STATUS Connected D Figure 10 DPC Console in Redirect State Figure 10 shows the DPC console window in redirect state with the terminal window The text appearing on the server monitor displays in the redirect window Configuration Software and Utilities Availability of DPC console features is determined by the following e The EMP access mode selected during configuration in the System Management Submenu of the BIOS Server Menu and e Whether the server s COM2 port is configured
31. Hard Drive Bays sans ete os 18 5 25 inch Removable Media Device Bay nn 18 Hot Swap Power Supplies Zr ar da nr eeee 19 SYSIENRGDB ING He ee ail A ili id ve 19 2 Boardset Description Boardset Features ee ai 22 Processor OV Wise lost traia 24 Memory OVEWISWe sas lella alan 25 DIMM Installation Sequence i 26 PernpheralS cantoria ee ee 27 SUPER O Chips oa e e ao 27 Add In Board Ste noie ea t chu area relega 27 Video reine ale 27 SOS Controller belle ee 28 IDE Controllers anelli leali 28 Keyboard MM reines i ego 28 server Management een 29 Front Panel G ntrollerfFPO r2 e2 iii ie cin 30 Hot swap Controller HSO an 2a heath a tad da 30 SER atte i increta eat atic Hr NIE Seed chide ER 31 o ea e A R eaa Aaa EA a Eea Eaa EASi 31 Secure Boot Mode ee 31 Boot Sequence Control scan ea 31 Boot Without Keyboard Sc ee ll lil e ei ee 32 Locked Power and Reset Switches 32 Diskette Write PROC sn ann tuent iena 32 Video BlANRINO Sr dio ale PR ie 32 Emergency Management Port EMP i 32 3 Configuration Software and Utilities Hot rilascio E 34 Power on Self Test POST 2 42 22 nie naine nine in Kade 34 Using BIOS Solsticio 35 Record Your Setup Settings sent ap 35 lf You Cannot Access SUP lite 35 Starting Sep ili ela iaia aa Ri 36 SOUP IME MUS com tenes te De te a net s 36 Main MAMU ee ee A en ee 38 Advanced Menu onice 41 Security UIE SRE ag aa fra sl enon Seolo Se dosi sn lesi ino Pull n
32. If the FPC is not present or is not functioning properly BIOS times out and continues 32 Boardset Description 3 Configuration Software and Utilities This chapter describes the Power on Self Test POST and system configuration utilities Table 5 briefly describes the utilities Table 5 Configuration Utilities Utility Description and brief procedure Page BIOS Setup Setup System Setup Utility SSU You can use Setup to change system configuration defaults 35 If the system does not have a diskette drive or the drive is disabled or misconfigured use Setup to enable it Or you can move the CMOS switch on the system board from the default setting Protect CMOS memory to the Clear setting this will allow most system configurations to boot For the procedure to do this see CMOS Clear Switch on page 183 Then run the SSU to configure the system Use for extended system configuration of onboard resources and 51 add in boards viewing the system event log SEL setting boot device priority or setting system security options The SSU can be run from either the configuration software CD ROM or from a set DOS bootable diskettes See the printed Quick Start Guide to make a set of SSU diskettes Information entered via the SSU overrides information entered via Setup Direct Platform Control DPC Console FRUSDR Load Utility BIOS Update Utility Firmware Update Utility QLogic SCSI Uti
33. Label and disconnect all cables connected to the add in boards installed in the expansion slots Remove all add in boards see Add In Boards on page 108 Label and disconnect all internal cables connected to the PHP I O carrier Remove and save the four screws securing the tray to the chassis Simultaneously rotate the eject insert levers to eject the tray from the midplane The levers are labeled B in Figure 34 Lift the tray from the chassis Working Inside the System Installing the I O Tray See Figure 34 1 Position the tray over the chassis and lower it onto its supports 2 Ensure that the midplane and I O carrier tray connectors are properly aligned 3 Simultaneously rotate the eject insert levers into the locked position This action also mates the PHP I O carrier connector with the midplane connector Use the screws you removed earlier to secure the I O tray to the chassis Connect all internal cables to the PHP I O carrier Install all add in boards see Add In Boards on page 108 Connect all peripheral device cables connected to the I O panel on the back of the system Install the top and 240 VA protective covers see Installing the Top Cover on page 99 REN AR OM10653 Figure 34 Removing the I O Tray A Screws four B Eject insert levers C O tray SRPL8 Server System Product Guide 115 Interchassis Management Bus ICMB Board Removing the ICMB Board See Figure 35 1 Observ
34. Midplane on page 140 Remove and save the screws that attach the AC filter to that chassis Remove and save the screws that attach the AC plugs to the chassis Remove the three plug retaining brackets Remove the AC filter and cable Installing the AC Filter and Cable 1 NP SN Remove the AC filter and cable from its protective wrapper Place the cable in position inside the chassis Install the three plug retaining brackets secure them with the screws you removed earlier Install the AC filter Install the midplane see Installing the Midplane on page 140 Peripheral Bay CAUTION Be careful not to scrape the diskette drive data cable on memory DIMMs when you remove or install the peripheral bay Damage to the cable and DIMMs could occur Removing the Peripheral Bay See Figure 36 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the memory module cover see Removing the Memory Module Cover on page 100 3 Remove and save the four screws that secure the peripheral bay to the chassis 4 Using the profusion carrier support as a handle the rectangular metal piece that protrudes vertically from the top of the peripheral bay slide the bay straight out away from the center of the chassis SRPL8 Server System Product Guide 117 Installing the Peripheral Bay 118 See Figure 36 1 Observe the safety precautions warnings and cautions at t
35. O carrier 21 I O riser board 21 memory modules 21 profusion carrier 21 voltages and currents 193 bootable media required by POST 34 booting cold 155 bus termination requirements SCSI devices 28 126 C cables routing for removable media bays 127 cache coherency filters installing 133 removing 132 Caution avoid damaging front panel board switches during installation 106 avoid damaging jumpers when changing 131 avoid damaging memory module DIMM sockets 142 avoid damaging profusion carrier tray switches during removal 106 DIMM types matching 145 DIMMs use extreme care when installing 145 do not overload PHP I O carrier 108 do not use hard drives in external bays 126 ESD protection 94 137 147 installing chassis covers for cooling and airflow 94 CD ROM drive activity LED 16 headphone jack 16 open close button 16 slide rails for drive 127 volume control 16 certifications 207 208 CFG files 51 CMOS clear to reconfigure diskette drive 35 configuring I O carrier switches general procedure to change 183 locations on I O carrier 182 retaining CMOS settings 183 retaining stored password 184 summary description 182 configuring system Setup 33 SSU 33 221 connector diskette drive 174 Intel Remote Management Card 175 parallel port 177 PCI 180 SCSI wide input 178 serial ports 177 VGA video port 176 controller diskette floppy drive 23 28 IDE 28 keyboard mouse 23 28
36. Pause Before Boot Enabled Disabled Worksheet 18 PCI Mode Submenu Option ROM Scan Disabled Enabled Enable Master Disabled Enabled Default lt time gt Latency Timer Worksheet 19 PCI Devices Submenu Option ROM Scan Disabled Enabled Enable Master Enabled Disabled Latency Timer Default lt time gt 204 Equipment Log and Configuration Worksheets Worksheet 20 I O Device Configuration Submenu Serial Port A Base 1 0 Address Interrupt Serial Port B Base 1 0 Address Interrupt Parallel Port Mode Base 1 0 Address Interrupt DMA channel Diskette controller Disabled Enabled Auto OS Controlled 3F8h 2F8h 3E8h 2E8h 4 3 Disabled Enabled Auto OS Controlled 3F8h 2F8h 3E8h 2E8h 4 3 Disabled Enabled Auto OS Controlled Output only Bidirectional EPP ECP 378 278 178 3BC 5 7 1 3 Disabled Enabled Worksheet 21 Advanced Chipset Control Submenu Base RAM Step 1 MB 1 KB Every location Extended RAM Step 1 MB 1 KB Every location L2 Cache Enabled Disabled ISA Expansion Aliasing Memory Scrubbing Enabled Disabled Restreaming Buffer Enabled Disabled Multiboot Support Enabled Disabled Enabled Disabled Worksheet 22 Security Menu Administrator Password is User Password is Password on Boot Secure Mode Timer Secure Mode Hot Key Secure Mode
37. To Change or Clear the User Password 1 Click lt User Password gt 2 Enter the old password in the first field 3 Enter the new password in the second field or leave blank to clear 4 Confirm the password by entering it again in the second field or leave blank to clear To Set the Administrator Password 1 Click lt Administrator Password gt 2 Enter the password in the first field 3 Confirm the password by entering it again in the second field SRPL8 Server System Product Guide 57 To Change or Clear the Administrator Password 1 2 3 4 Click lt Administrator Password gt Enter the old password in the first field Enter the new password in the second field or leave blank to clear Confirm the password by entering it again in the second field or leave blank to clear Security Options The security options available to you depend on your platform The list below is representative Click lt Options gt to set the security options Hot Key sets a key sequence that puts the server into secure mode when the key is pressed Lock Out Timer sets an interval that puts the server into secure mode when no activity occurs during the interval Secure Boot Mode forces the server to boot directly into secure mode Video Blanking turns off the video when the server is in secure mode Floppy Write controls access to the diskette drive when the server is in secure mode Front Panel Lockout control the p
38. all records in the SDR repository sorted by record type Settings Display Hex Displays SDR records in hex format Display Verbose Displays SDR records in verbose format Output Text Saves SDR data in verbose format Output Binary Saves SDR data in binary format Help About Displays SDR Manager version information Field Replaceable Unit FRU Manager Add In The FRU Manager can display the FRU inventory areas in either hex or verbose format In this window you can e Examine all FRU inventory areas on the server in either hex or verbose mode e Examine individual FRU inventory areas in either hex or verbose mode e Examine FRU inventory of the BMC only in either hex or verbose mode e Save the FRU inventory areas to a file in either text or binary form for the BMC only The FRU manager s main window provides access to features of the add in through menus Each option included on the main menu supports an accelerator key Accelerator keys are indicated by an underlined letter in the text listing the option SRPL8 Server System Product Guide 61 Figure 8 shows the FRU Manager main window Table 9 lists the window s menus and options nn FRU Manager View Settings Help Common Header Area Vess ion 01h Length Internal Area Offset Oth Chassis Area Offset OEh Board Area Offset 12h Product Area Offset 1Ah PAD 00h PAD 00h CheckSum C4h End of the Fields in this Section Dislpay Internal
39. any key to continue POST SRPL8 Server System Product Guide 49 Exit Menu The following menu options are available on the Server menu Select an option by using the Up or Down arrow keys Then press lt Enter gt to execute the option and follow the prompts Option Description Exit Saving Changes Exit Setup and save changes Exit Discarding Changes Exit Setup without saving changes Load Setup Defaults Load default values for all Setup items Load Custom Defaults Load settings from Custom Defaults Save Custom Defaults Save changes as Custom Defaults If CMOS fails BIOS uses Custom Defaults if available If not it uses the factory defaults Discard Changes Load previous values of all Setup items Save Changes Save all changes 50 Configuration Software and Utilities Using the System Setup Utility SSU The SSU is on the configuration software CD ROM shipped with the server The SSU provides a graphical user interface GUI over an extensible framework for server configuration The SSU framework supports the following functions and capabilities e Assigns resources to devices and add in boards before loading the OS e Lets you specify boot device order and system security options e Permits viewing and clearing of the system event log SEL e Permits viewing of the system field replaceable units FRUs and sensor data records SDRs e Allows troubleshooting of the server when the OS is not ope
40. coprocessor significantly increases the speed of floating point operations and complies with ANSI IEEE standard 754 1985 Each S E C cartridge connects to one of two processor mezzanine boards through a 330 pin Slot 2 edge connector SC330 1 The cartridge is secured to the mezzanine carrier by a retention bracket Each mezzanine board connects to the profusion carrier Depending on configuration your system has one to eight processors The processor external interface is multiprocessor MP ready and operates at 100 MHz The processor contains a local APIC unit for interrupt handling in MP and uniprocessor UP environments The L2 cache is located on the same die as the processor core and L1 cache The cache e Is offered in 1 MB and 2 MB configurations e Is ECC protected e Operates at the full core clock rate Boardset Description Memory Overview Main memory resides on two add in boards called memory modules Each memory module contains slots for 16 DIMMs and is attached to the profusion carrier through a 300 pin connector on the midplane The memory controller supports PC 100 registered SDRAM DIMMs Various DIMM sizes are supported but each DIMM must be at least 128 MB Memory amounts from 128 MB to 16 GB per module are supported The ECC used for the memory module is capable of correcting single bit errors SBEs and detecting 100 of double bit errors over one code word Nibble error detection is also provided You can install
41. el fabricante del equipo Para deshacerse de las pilas usadas siga igualmente las instrucciones del fabricante El sistema esta dise ado para funcionar en un entorno de trabajo normal Escoja un lugar e Limpio y libre de part culas en suspensi n salvo el polvo normal e Bien ventilado y alejado de fuentes de calor incluida la luz solar directa e Alejado de fuentes de vibraci n e Aislado de campos electromagn ticos fuertes producidos por dispositivos el ctricos e En regiones con frecuentes tormentas el ctricas se recomienda conectar su sistema a un eliminador de sobrevoltage y desconectar el m dem de las l neas de telecomunicaci n durante las tormentas e Provisto de una toma de tierra correctamente instalada e Tenga espacio suficiente para acceder al cable de alimentaci n del servidor ya que sirve para desconectar la alimentaci n principal del producto SRPL8 Server System Product Guide 219 220 Warnings Index A AC filter and cable installing 117 removing 117 add in board current limitations 108 installing replacing 108 PCI 108 109 removing 111 sensitive to ESD 94 address I O 185 agency certification 207 208 EMC standards 207 EU Directive 207 audible beep error codes 34 B battery disposing of safely 152 installing 153 removing 152 beep codes 34 BIOS changing the language 79 recovering 79 update utility 33 upgrading 77 board set I
42. following hex format The data are separated by a sensor record number X header where X is the number of that sensor record in the SDR area The next line after the header is the sensor record data in hex format delineated by spaces Each line holds up to 16 bytes The data on each line are followed by the same data in ASCII format nonprintable characters ch lt 32 Il ch gt 126 are substituted by a period Example To display the SDR area type frusdr d sdr and press lt Enter gt Using Specified CFG File The utility can be run with the command line parameter of cfg filename cfg The filename can be any DOS accepted eight character filename string The utility loads the specified CFG file and uses the entries in that file to probe the hardware and to select the proper SDRs to load into nonvolatile storage Displaying Utility Title and Version The utility displays its title FRU amp SDR Load Utility Version X X Revision X XX where X XX is the revision number for the utility SRPL8 Server System Product Guide 75 Configuration File The configuration file is in ASCII text The utility executes commands formed by the strings present in the configuration file These commands cause the utility to run tasks needed to load the proper SDRs into the nonvolatile storage of the BMC and possibly generic FRU devices Some of the commands may be interactive and require you to make a choice Prompting for Product Level FRU Information
43. for console redirect in BIOS The three EMP access modes are disabled preboot and always active Table 10 DPC Console Access Modes server configured for console redirect Mode Server is powered off During POST After OS boots Disabled Redirect window appears but is blank Redirect window Redirect window Preboot EMP commands available Redirect window Redirect window Always Active EMP commands available Redirect window EMP commands available bi You can modify the operation mode by selections in the POST reset and POST power up dialogs These are server control dialogs available with the DPC Console Table 11 DPC Console Access Modes server NOT configured for console redirect Mode Server is powered off During POST After OS boots Disabled Redirect window appears but is Redirect window Redirect window appears blank appears but is blank but is blank Preboot EMP commands available EMP commands Redirect window appears available but is blank Always Active EMP commands available EMP commands EMP commands available available DPC Console Requirements This section outlines the requirements and configurations necessary for using the DPC console Operating Systems e Windows 98 or later 16MB of RAM 32 MB recommended 20 MB disk space e Windows NT Windows NT 4 0 or later 24 MB of RAM 32 MB recommended 20 MB disk space Client Configuration The DPC console will s
44. grounding clip removable media drives 126 hard disk drive bay size and capacity 18 installing in hot swapping bay 86 SCSI 84 hot key option quick reference 34 hot swap controller 30 hot swapping hard disk drives 14 hot swapping bay status indicators 87 VO address 185 riser board 23 connectors 23 installing 112 removing 111 tray installing 115 removing 114 I O carrier 23 CMOS settings switches 183 configuration switches 182 configuring switches 182 diskette drive connector 174 installing 138 Intel Remote Management Card connector 175 parallel port 177 password clear switch 184 PCI connectors 180 recovery boot switch 184 serial ports 177 video port connector 176 ICMB See Interchassis Management Bus IDE controller 28 interface 23 223 224 indicators cooling fault LED yellow 16 drive fault LED yellow 16 front panel LCD 16 power fault LED yellow 16 SCSI drive in recovery mode 87 SCSI drive status descriptions 87 input voltage 19 Intel Remote Management Card IRMC connector 175 Interchassis Management Bus ICMB board installing 116 removing 116 interconnect backplane 23 interrupt mapping 187 ISA 21 J K jumpers do not damage when changing 131 keyboard compatibility 28 lockout timer setting in SSU 28 keyboard mouse controller 23 L language changing in BIOS 79 LCD module installing 103 removing 102 lights CD ROM drive 16 DC power 16
45. into the bay until the slide rails lock in place 8 Connect a power cable to the drive The connectors are keyed and can be inserted in only one way 9 Connect the data cable to the drive The connectors are keyed and can be inserted in only one way SRPL8 Server System Product Guide 127 Removing a 5 25 inch Peripheral from the Front Bay 128 PANAS mn Observe the safety and ESD precautions at the beginning of this chapter Remove the peripheral bay see Removing the Peripheral Bay on page 117 Disconnect the power and data cables from the drive The drive has two protruding plastic snap in rails attached Squeeze the rail tabs toward each other as you carefully slide the drive forward out of the bay and place it on an antistatic surface Remove and save the four screws and two slide rails If you leave the bay empty install a stainless steel EMI shield on the bay for proper cooling and airflow If you do not replace a SCSI device with another SCSI device modify the cable and termination arrangement so that a proper termination exists at the end of the cable it can be a termination device only not necessarily a SCSI peripheral OM07359 Figure 42 Removing a Media Device A CD ROM Drive B Plastic snap in slide rail C Retaining tab on rail D Power cable E Data cable Working Inside the System 6 Upgrading Boardset Components This chapter describes procedures for removing and installing
46. is detailed in Recovery Boot Switch on page 184 After doing the procedure leave the upgrade disk in drive A and turn on the server then continue with the BIOS upgrade see page 78 Changing BIOS Language You can use the BIOS upgrade utility to change the language that BIOS displays Use a bootable diskette containing the Intel flash utility and language files see page 78 1 Boot the computer with the bootable diskette in drive A The BIOS upgrade utility screen appears 2 Select Update Flash Memory from a file 3 Select Update Language Set Press lt Enter gt 4 Select drive A and use the arrow keys to select the correct Ing file Press lt Enter gt 5 When asked toconfirm that you want to flash the new language into memory select Continue with Programming Press lt Enter gt 6 When the utility displays the message that the upgrade is complete remove the diskette Press lt Enter gt 7 The computer will reboot and the changes will take effect SRPL8 Server System Product Guide 79 Using the Firmware Update Utility The Firmware Update Utility is a DOS based program that updates the BMC s firmware code You need to run the utility only if new firmware code is necessary Running the Firmware Update Utility 1 Create a DOS bootable diskette The version of DOS must be 6 0 or higher 2 Place the firmware update utility FWUPDATE EXE and the hex file on the diskette Make a note of the hex file name
47. major system boards and components This includes procedures for Table 15 Procedures in Chapter 6 Item Page Item Page e Cache Coherency Filters 134 e Midplane 140 e Processor retention bracket 134 e Memory modules and DIMMs 142 e Mezzanine board s 135 e Processors 147 e Profusion carrier 136 e FSB Termination Board Assembly 150 e PHP I O carrier 138 Backup battery 152 Tools and Supplies Needed Phillips cross head screwdriver 1 and 2 bit Small flat bladed screwdriver Jumper removal tool or needle nosed pliers Antistatic wrist strap and conductive foam pad recommended Pen or pencil Equipment log as you integrate new parts into the system add information about them to your equipment log page 197 Record the model and serial number of the system all installed options and any other pertinent information specific to the system You will need this information when running the SSU 129 Warnings and Cautions These warnings and cautions apply throughout this manual to any procedure in which you access the inside of the server WARNINGS Avoid burns If the system has been running any installed processor and heat sink on the processor board s will be hot To avoid the possibility of a burn be careful when removing or installing components that are located near processors System power on off The DC push button on off switch a convex button on the front panel DOES NO
48. on light should be lit Are the system power cords properly connected to the system and plugged into a NEMA 6 15R outlet for 200 240 V Is AC power available at the wall outlet If these items are correct but the problem recurs see More Problem Solving Procedures on page 157 155 Running New Application Software Problems that occur when you run new application software are usually related to the software Faulty equipment is much less likely especially if other software runs correctly Checklist e Does the system meet the minimum hardware requirements for the software See the software documentation e Is the software an authorized copy If not get one unauthorized copies often do not work e If you are running the software from a diskette is it a good copy e If you are running the software from a CD ROM disk is the disk scratched or dirty e If you are running the software from a hard disk drive is the software correctly installed Were all necessary procedures followed and files installed e Are the correct device drivers installed e Is the software correctly configured for the system e Are you using the software correctly e If the problems persist contact the software vendor s customer service representative After the System Has Been Running Correctly Problems that occur after the system hardware and software have been running correctly often indicate equipment failure Many situations that are easy
49. orage e Muni d une prise murale correctement mise la terre e Suffisamment spacieux pour vous permettre d acc der aux c bles d alimentation ceux ci tant le seul moyen de mettre le syst me hors tension e Un espace suffisant est n cessaire pour acc der au cordon d alimentation du serveur celui ci jouant le r le de d connecteur d alimentation principale du produit SRPL8 Server System Product Guide 213 WARNUNG Deutsch Benutzer k nnen am Netzgerat dieses Produkts keine Reparaturen vornehmen Das Produkt enthalt m glicherweise mehrere Netzger te Wartungsarbeiten m ssen von qualifizierten Technikern ausgef hrt werden Versuchen Sie nicht das mitgelieferte Netzkabel zu ndern oder zu verwenden wenn es sich nicht genau um den erforderlichen Typ handelt Der Wechselstrom des Systems wird durch den Ein Aus Schalter f r Gleichstrom nicht ausgeschaltet Ziehen Sie jedes Wechselstrom Netzkabel aus der Steckdose bzw Dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus 2 Schalten Sie das System mit dem Hauptschalter aus 3 Ziehen Sie den Stromanschlu stecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Syste
50. page 17 Each supply is designed to minimize EMI and RFI This system is designed to operate at 100 200 VAC only The DC output voltages of each power supply are e 33 V at 36 0 A max e 5 V at 36 0 A max total combined output of 3 3 V and 5 5 V not to exceed 195 W e 12 V at 36 0 A with 42 0 A lt 10ms peak e 24 V at 100 mA e 12Vat1 0A e 5 V standby 1 0 A Each supply docks to a 36 pin connector on the system midplane System Cooling The server contains two independent cooling subsystems e The upper system cooling the front panel profusion carrier and I O carrier 5 1 redundancy e The lower system cooling the memory modules peripheral bay and power supplies 2 1 redundancy Both subsystems offer redundant cooling capabilities As shipped from the factory the minimum configuration includes six system fans in the upper subsystem and two power supplies each has an integrated fan You can install one additional power supply gt NOTE All chassis covers must be on the system for proper cooling SRPL8 Server System Product Guide 19 20 Chassis Description Boardset Description The modular scaleable architecture of the SRPL8 rack server supports symmetrical multiprocessing SMP and a variety of operating systems The server comes with Peripheral Component Interconnect PCI and Industry Standard Architecture ISA buses ISA buses are used internally only The system has no ISA slots or a way
51. page 197 Slide the replacement power supply into the power supply cavity Lift the power supply handle to lock it into place Hot Swapping Fans SCSI Hard Drives and Power Supplies Part Il Service Technician s Guide Working Inside the System Upgrading Boardset Components Solving Problems Technical Reference Power System Description Calculating Power Usage Equipment Log and Configuration Worksheets 5 6 7 8 A B C Regulatory Specifications D Warnings A WARNING Only a QUALIFIED SERVICE TECHNICIAN is authorized to remove the server covers and to access any of the components inside the server Before removing the covers see Safety Before You Remove Server Covers on page 93 and Warnings and Cautions on page 94 This manual is divided into two parts e User s Guide beginning on page 11 describes procedures that DO NOT REQUIRE internal server access You do not need to be a qualified service technician to perform procedures listed in the User s Guide e Service Technician s Guide beginning on page 91 describes procedures that REQUIRE internal server access You must be a qualified service technician to perform procedures listed in the Service Technician s Guide 91 92 Part Il Service Technician s Guide 5 Working Inside the System This chapter describes procedures for removing and installing most components inside the system Table 14 lists these procedures and thei
52. power supply failure LED on the front panel starts flashing The supply can be hot swapped removed and replaced without turning off the power or impacting server operations providing that 3 power supplies are installed 191 Power Supply Input Voltages Table 34 Power Supply AC Input Ratings Parameter Minimum Nominal Maximum Units V in 230 90 180 110 120 200 240 132 264 AC Input Current 13 110 VAC Ampere 7 220 VAC The 750 watt autoranging power supplies are capable of handling up to two hard drives at 28 watts per drive typical 3 5 inch wide by 1 inch high 10 K RPM drives eight processors at a maximum of 65 watts per processor and up to 32 GB of PC100 registered DIMMs The total power requirement for the board set exceeds the 240 VA energy hazard limit that defines an operator accessible area The 240 VA protection circuits protect the user from a 240 VA energy hazard while hot swapping installing or removing a hard disk drive or fan system Power Supply Output Voltages Table 35 Power Supply Output Ratings 110 V 220 V Two Supplies Three Supplies Power Supply Outputs Individual Supply Nonredundant Redundant 3 3 V 31 A 36 A 58 68 58 68 A 5V 31 A 36 A 58A 64 A 58 A 64 A 12V 31A 36A 58 68 58 A 68 A 12V 1A 1A 1A 5 V Standby 1A 1 75A 1 75 A Vbias 15 V 200 mA 200 mA 100 mA 1 Forced load sharing is for 5
53. power supply on off control 6 12C_BACKUP_SDA 7 VCC_STDBY 8 KEYLOCK_FROM_SFC_L Keyboard lock signal 9 NMI_5V Nonmaskable interrupt indication 10 VCC3 3 3V power supply status input 11 RST_SFC_L Baseboard reset signal from Server Monitor Module 12 GND Ground 13 GND Ground 14 Reserved N A 15 SECURE_MODE_BMC Secure mode indication 16 GND Ground 17 INSTRUSION_L 18 SMM_NMI_L 19 INIT_L 20 GND Ground 21 KB_DATA 22 MS_DATA 23 KB_CLK 24 MS_CLK 25 Key pin N C Connector key 26 RESET BMC OC _L SRPL8 Server System Product Guide 175 VGA Video Port 15 11 OM04417 Table 20 Video Port Connector Pinout Pin IN OI A N gt Signal Red Green Blue N C GND GND GND GND Pin 10 11 12 13 14 15 Signal N C GND NC DDCDAT HSYNC VSYNC DDCCLK Keyboard and Mouse 6 O 4 O NO O 2 1 LB O o 3 Y OM11313 The PS 2 compatible connectors share a common housing they are functionally equivalent Table 21 Keyboard and Mouse Connector Pinouts Pin Keyboard signal Pin Mouse signal 1 KEYDAT 1 MSEDAT 2 NC 2 NC 3 GND 3 GND 4 FUSED_VCC 5 V 4 FUSED_VCC 5 V 5 KEYCLK 5 MSECLK 6 NC 6 NC 176 Technical Reference Parallel Port 13 Oe 000000000000 25 Table 22 Parallel Port Connecto
54. presa a terra del telaio del sistema qualsiasi superficie non dipinta 6 Non far operare il sistema quando il telaio senza le coperture Dopo aver seguito i sei passi di SICUREZZA sopracitati togliere le coperture del telaio del sistema come seque 1 Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sistema rimettere sempre le coperture del telaio prima di riaccendere il sistema Operare il sistema senza le coperture al loro proprio posto potrebbe danneggiare i componenti del sistema Per rimettere le coperture del telaio 1 Controllare prima che non si siano lasciati degli attrezzi o dei componenti dentro il sistema 2 Controllare che i cavi dei supporti aggiuntivi ed altri componenti siano stati installati appropriatamente 3 Attaccare le coperture al telaio con le viti tolte in precedenza e avvitarle strettamente 4 Inserire e chiudere a chiave il lucchetto sul retro del sistema per impedire l accesso non autorizzato al sistema 5 Ricollegare tutti i cavi esterni e le prolunghe AC del sistema continua 216 Warnings AVVERTENZA Italiano continua Se il sistema stato a lungo in funzione il microprocessore e il dissipatore di calore potrebbero essere surriscaldati Fare attenzione alla presenza di piedini app
55. push the PCI cover toward the back of the server to disengage the tabs from the top cover 4 Remove the cover and set it aside OM10750 Figure 22 Removing the PCI Bus Hot Plug Cover A Screws 2 Installing the PCI Bus Hot Plug Cover 1 Ensure that add in boards are firmly seated in their respective slots and that the retaining brackets for the add in boards are reinstalled Position the hot plug cover over the top cover so that the tabs along its edges align with the slots in the top cover Lower the hot plug cover until it rests on the top cover Push the hot plug cover toward the front of the server to engage the row of tabs attaching the hot plug cover to the top cover Attach the hot plug cover to the top cover using the screws you removed earlier SRPL8 Server System Product Guide 97 Removing the Top Cover See Figure 23 page 98 and Figure 24 page 99 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Turn off all peripheral devices connected to the server 3 Turn the server off with the push button on off power switch on the front panel 4 Unplug the AC power cord from the power inlet receptacle or from the power source outlet 5 Label and disconnect all peripheral cables attached to the I O panel on the back of the server 6 Remove and save the screws that attach the top cover to the chassis gt NOTE It is not necessary to remove the PCI bus hot plug cove
56. static free surface or store it in an antistatic protective wrapper Installing a Memory Module See Figure 48 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Being careful not to touch the components on the memory module remove it from its protective wrapper Place the module DIMM side up on a nonconductive static free surface Record the serial number of the memory module in your equipment log page 197 4 Remove any installed DIMMs from the module you removed earlier Install them in the new memory module Si gt NOTE Install the memory module DIMM side down 142 Upgrading Boardset Components 5 Grasp the memory module by the sides and carefully slide it into the slot guides until the levers engage with the flanges in front of the guides 6 Simultaneously rotate the levers inward until they are flush with the edge of the module to seat the connector of the module in the connector of the midplane 7 Ifyou removed the LCD module reinstall it 8 Reinstall the memory module cover OM10703 Figure 48 Removing a Memory Module A Memory Module Cover SRPL8 Server System Product Guide 143 Removing DIMMs CAUTION Use extreme care when removing a DIMM Too much pressure can damage the socket slot Apply only enough pressure on the plastic ejector levers to release the DIMM 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Remove each mem
57. the SSU Use these six user customizable settings BackColor default 3 lets you change the BACKGROUND color associated with different items on the screen to predefined color combinations The changes are instantaneous Color default 0 lets you change the WINDOW color preference selection to predefined color combinations The changes are instantaneous UserMode default expert lets you set the desired expertise level Novice Intermediate Expert The expertise level determines which tasks are visible in the Available Tasks section and what actions each task performs For a new mode setting to take effect you must exit the SSU and restart it In the current implementation there is no distinction between these three different modes Language default EN lets you change the text displayed in the SSU to the appropriate language For a new language setting to take effect you must exit the SSU and restart it For a list of Alpha 2 language codes see the SO 639 1988 and ISO 3166 1993 specifications Locale default US lets you change the current locale used in the SSU environment For a new locale to take effect you must exit the SSU and restart it For a list of Alpha 2 locale codes see the ISO 639 1988 and ISO 3166 1993 specifications Other lets you change other miscellaneous options in the SSU The changes are immediate To change the interface default values Use the mouse to click the proper butt
58. to correct however can also cause such problems sometimes the problem stems from changes made to the system such as hardware or software that has been added or removed Checklist 156 e Ifyou are running the software from a diskette try a new copy of the software e Ifyou are running the software from a CD ROM disk try a different disk to see if the problem occurs on all disks e Ifyou are running the software from a hard disk drive try running it from a diskette If the software runs correctly there might be a problem with the copy on the hard disk drive Reinstall the software on the hard disk and try running it again Make sure all necessary files are installed e If the problems are intermittent there may be a loose cable dirt in the keyboard if keyboard input is incorrect a marginal power supply or other random component failures e If you suspect that a transient voltage spike power outage or brownout might have occurred reload the software and try running it again Symptoms of voltage spikes include a flickering video display unexpected system reboots and the system not responding to user commands NOTE Random errors in data files If you are getting random errors in your data files they may be getting corrupted by voltage spikes on your power line If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line you might want to install a surge suppressor between the pow
59. upper midplane support bracket then secure it with the three screws you removed earlier 6 Install the I O tray Install the profusion carrier tray 8 Install power supplies OM07504 Figure 47 Midplane Grand connector Memory module connector Peripheral power connector Memory module connector vom SRPL8 Server System Product Guide 141 Memory Modules and DIMMs Removing and Installing CAUTION To avoid damaging the memory module DIMM sockets do not attempt to use the metal stiffener on the memory module as a handle Removing a Memory Module See Figure 48 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Remove the memory module cover A see Removing the Memory Module Cover on page 100 3 Simultaneously rotate the eject insert levers of the memory module outward about 90 to disengage the pin and socket connector of the module from the pin and socket connector of the midplane A CAUTION Support Memory Module During Removal Support the entire length of the memory module as you slide it out of the chassis The module is more than 12 inches long and could be damaged if you allow it to bend by supporting only one end 4 Being careful not to touch the components on the memory module slide it out of the slot guides 5 Place the module DIMM side up on a nonconductive
60. video 23 27 controllers front panel 30 hot swap 30 controls and indicators CD ROM drive 16 diskette drive 16 front panel 16 status LEDs hot swapping bays 16 cooling do not use hard drives in external bays 126 filler panels removable media bays 126 installing all covers for correct airflow 94 installing metal EMI shield 128 system 14 cooling and airflow 96 covers PCI hot plug removing 97 removable 96 top installing 99 removing 98 current usage 193 D DC outputs 19 diagnostics preparing system for testing 157 using PCDiagnostics 157 DIMM memory installation sequence 26 145 installing 145 removing 144 Direct Platform Control DPC console 33 63 main console window 67 phonebook 71 requirements 65 server control operations 68 diskette drive connector on VO carrier 174 drive controller 23 28 drive ejector button 16 installing drive in bay 125 media supported 18 reconfiguring if cannot enter Setup 35 removing bracket from drive 124 removing drive from bay 124 routing drive cable 125 running SSU from 33 34 DPC See Direct Platform Control drive 3 5 inch bay 14 5 25 inch bays 18 5 25 inch drive bay size and capacity 18 limiting use of hard drives 18 diskette media supported 18 hard drive bays 18 maximum ambient temperature 18 maximum watts total 18 drive fault light slow blinking 87 drive indicators SCSI drive active 87 drive failure 87 drive present
61. 1 Interrupt controller 1 01F0 01F7 Primary IDE controller 0022 0040 Unused reserved 0278 027F Parallel port 2 relocatable 0040 005F Programmable timer 02E8 02EF Serial port 4 relocatable 0060 amp 0064 Keyboard controller 02F8 02FF Serial port 2 relocatable 0061 NMI status amp control register 0370 0377 Secondary diskette 0070 NMI mask bit and RTC index address 0378 037F Parallel port 1 relocatable 0071 RTC 03BC 03BF Parallel port 3 0072 RTC extended index register 03E8 03EF Serial port 2 relocatable 0073 RTC extended data register 03F8 03FF Serial port 1 relocatable 0080 008F DMA low page register OCF8 PCI config address register 0092 Port 92 register OCFC PCI data address register 00A0 00A1 Interrupt controller 2 OCF9 Reset control 00B2 Advanced pwr management control 04D0 04D1 INTC edge level register 00B3 Advanced power management status 0C00 0C7F Pwr management base address 00C0 00DF DMA controller OCA8 OCAF SMIC decoder 00F0 Coprocessor error 0CCO OCCF SM base address 2000 FFFF Allocated to the PCI devices SRPL8 Server System Product Guide 185 Memory Map Table 31 lists the system memory map When BIOS allocates memory space to PCI devices it starts just below the APICs and continues downward Assigning memory space to PCI devices does not decrease the total available memory in the system because this memory is reclaimed above
62. 3 3 and 12 V only The 5 V standby load sharing is the technique for passive load sharing 192 Power System Description Calculating Power Usage Server Current Usage Table 36 lists the current usage for both minimally and fully configured servers You can easily calculate power usage in the server from the numbers provided The table is for reference only It is not meant to provide the exact current usage in the server exact values depend on exact configuration size and number of processors DIMMs hard drives add in boards etc Table 36 Server Boardset Voltages and Currents Board Spec Units 3 3V 5V 12V 12V 5VSB 15 VSB Power VO carrier Min load Adc 0 20 0 70 0 00 0 20 0 65 0 00 9 81 Max load Adc 7 99 45 20 5 00 1 20 0 75 0 00 330 52 Max step load Adc 2 00 12 17 4 50 0 25 0 10 0 00 Profusion carrier with mezzanines Min load Adc 4 60 0 75 0 25 0 000 0 00 0 00 21 93 Max load Adc 12 00 1 50 46 00 0 000 0 00 0 00 599 10 Max step load Adc 2 00 0 75 18 00 0 00 Front panel plugs into profusion carrier Min load Adc 0 00 0 05 200 0 001 0 10 000 24 76 Max load Adc 0 00 0 23 5 40 0 010 0 25 0 00 67 32 Max step load Adc 0 18 0 10 0 001 0 15 0 00 Memory carrier 1 Min load Ade 1 20 0 00 0 00 0 000 0 00 0 00 3 96 Max load Adc 23 00 0 00 0 00 0 000 0 00 0 00 75 90 Max step load Adc 8 00 Memory carrier 2
63. 5 Schlie en Sie alle externen Kabel und den AC Stromanschlu stecker Ihres Systems wieder an Fortsetzung 214 Warnings WARNUNG Deutsch Fortsetzung Der Mikroprozessor und der K hler sind m glicherweise erhitzt wenn das System in Betrieb ist Au erdem k nnen einige Platinen und Geh useteile scharfe Spitzen und Kanten aufweisen Arbeiten an Platinen und Geh use sollten vorsichtig ausgef hrt werden Sie sollten Schutzhandschuhe tragen Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr Die Batterie darf nur durch denselben oder einen entsprechenden vom Hersteller empfohlenen Batterietyp ersetzt werden Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend Das System wurde f r den Betrieb in einer normalen B roumgebung entwickelt Der Standort sollte e sauber und staubfrei sein Hausstaub ausgenommen e gut gel ftet und keinen Heizquellen ausgesetzt sein einschlie lich direkter Sonneneinstrahlung e keinen Ersch tterungen ausgesetzt sein e keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen e in Regionen in denen elektrische St rme auftreten mit einem berspannungsschutzger t verbunden sein w hrend eines elektrischen Sturms sollte keine Verbindung der Telekommunikationsleitungen mit dem Modem bestehen e mit einer geerdeten Wechselstromsteckdose ausger stet sein e Uber ausreichend
64. 61 3 3V AD59 AD57 GND AD55 AD53 GND AD51 AD49 3 3V AD47 AD45 GND AD43 AD41 5V AD39 AD37 3 3V AD35 AD33 GND RESERVED RESERVED GND SRPL8 Server System Product Guide 181 Configuration Switches One header provides eight switches that control various configuration options Figure 57 shows the switches SW4G1 Reserved 1 A 1 Recovery Boot 2 a Spare 3 1 BIOS Write Enable A Clear CMOS S Password Clear 6 a PHP Override 7 A 1 Reserved 8 Ma Figure 57 I O Carrier Configuration Switches Table 29 1 0 Carrier Switch Summary Items in bold show default placement for each configurable option Switch Default Function Number Setting What it does at system reset Disabled N A Reserved 1 Recovery Boot 2 Enabled BIOS attempts a recovery boot loading BIOS code from a diskette into the flash device This is typically used when BIOS code has been corrupted Disabled System attempts to boot using BIOS stored in flash memory Disabled N A Disabled No BIOS flash update allowed Enabled Allow BIOS flash update CMOS Clear 15 Enabled Replaces the contents of NVRAM with the manufacturing default settings Disabled Preserves the contents of NVRAM Password Clear 6 Enabled Clears the current system password Disabled Maintains the password PHP Override 7 Disabled N A Reserved 8 Disabled N A Spare Reserved 3 BIOS Update 4
65. 87 E electromagnetic compatibility See EMC electromagnetic interference See EMI electrostatic discharge See ESD EMC compatibility 208 compliance with standards 207 notice of test and compliance international 208 notice of test and compliance USA 208 Emergency Management Port EMP FRU viewer 72 using 32 Index EMI 14 grounding clip removable media 126 limit use of 5 25 inch hard drives 126 metal shield over removable media bay 126 metal shield removing installing 128 EMP See Emergency Management Port environmental specifications 207 equipment log 197 error codes and messages 167 messages 34 162 ESD 108 add in boards 94 108 131 avoiding damage to product 131 grounding clip removable media drives 126 limit use of 5 25 inch hard drives 126 EU directive compliance 207 expanded video memory 27 expansion slots 64 bit PCI 23 F fan description of system fans 14 removing 82 replacing 82 fan array housing installing 101 removing 101 FCC Class A 208 feature summary back controls and features 17 boardset 22 chassis 14 front controls and indicators 15 filler panel save panels 126 firmware update utility 33 80 front panel board 23 controller 30 controller board installing 106 removing 106 switches 23 SRPL8 Server System Product Guide front side bus FSB terminator module 23 installing 151 removing 150 FRUSDR load utility 33 72 when to run 73 G H
66. A72 A73 A74 A75 A76 A77 A78 A79 A80 A81 A82 A83 A84 A85 A86 A87 A88 A89 A90 A91 A92 A93 A94 Signal GND AD9 GND GND C BEO_L 3 3V AD6 AD4 GND AD2 ADO 3 3V REQ64_L 5V 5V GND C BE7_L C BE5 L 3 3V PAR64 AD62 GND AD60 AD58 GND AD56 AD54 3 3V AD52 AD50 GND AD48 AD46 GND AD44 AD42 3 3V AD40 AD38 GND AD36 AD34 GND AD32 RESERVED GND RESERVED Pin B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32 B33 B34 B35 B36 B37 B38 B39 B40 B41 B42 B43 B44 B45 B46 B47 Signal 12V TCK GND TDO 5V 5V INTB_L INTD_L PRSNT1_L RESERVED PRSNT2_L 3 3V Keywa RESERVED GND CLK GND REQ_L 3 3V AD31 AD29 GND AD27 AD25 3 3V C BE3 L AD23 GND AD21 AD19 3 3V AD17 C BE2 L GND IRDY_L 3 3V DEVSEL L GND LOCK L PERR L 3 3V SERR_L 3 3V C BE1_L AD14 GND AD12 Pin B48 B49 B50 B51 B52 B53 B54 B55 B56 B57 B58 B59 B60 B61 B62 B63 B64 B65 B66 B67 B68 B69 B70 B71 B72 B73 B74 B75 B76 B77 B78 B79 B80 B81 B82 B83 B84 B85 B86 B87 B88 B89 B90 B91 B92 B93 B94 Signal AD10 M66EN GND GND AD8 AD7 3 3V AD5 AD3 GND ADI 3 3V ACK64_L 5V 5V RESERVED GND C BE6 L C BE4 L GND AD63 AD
67. ABLE Disable A20 address line Install CD ROM for boot Clear huge ES segment register Fixup MPTABLE Search for option ROMs One long and two short beeps on checksum failure Shadow option ROMs Set up Power Management Initialize security Enable hardware interrupts continued SRPL8 Server System Product Guide 165 Table 16 Port 80 Codes continued POST Code 9F AO A2 A4 A8 AA AC AE BO B2 B4 B5 B6 B7 B8 B9 BA BC BD BE BF Co C1 C2 C3 DO D2 D4 D6 D8 DA DC DE DF FB FC FD 166 Beeps 4 1 1 1 4 2 4 4 Error Initialize local bus hard disk controller Set time of day Check key lock Initialize typematic rate Erase F2 prompt Scan for F2 key stroke Enter SETUP Clear in POST flag Check for errors POST done prepare to boot operating system One short beep before boot Display MultiBoot menu Check password optional Initialize ACPI Clear global descriptor table Prepare to boot Initialize DMI Clear parity checkers Invoke boot menu Clear screen optional Check virus and backup reminders Try to boot with INT 19 Beep code if disabling A20 fails Initialize the POST Error Manager Log POST Errors Display POST Errors Interrupt handler error Unknown interrupt error Pending interrupt error Initialize option ROM error Shutdown error Extended Block Move Shutdown 10 error Keyboard controller error A20 Error FRB in progress Five second wait for BMC to
68. AVERTISSEMENT Fran ais WARNUNG Deutsch AVVERTENZA Italiano ADVERTENCIAS Espa ol WARNING English US The power supply in this product contains no user serviceable parts There may be more than one supply in this product Refer servicing only to qualified personnel Do not attempt to modify or use the supplied AC power cord if it is not the exact type required The DC push button on off switch on the system does not turn off system AC power To remove AC power from the system you must unplug the AC power cord from the wall outlet or power supply SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connected to the system 2 Turn off the system by using the push button on off power switch on the system 3 Unplug all AC power cords from the system or from wall outlets 4 Label and disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 6 Do not operate the system with the chassis covers removed After you have completed the six SAFETY steps above you can remove the system covers To do this 1 Unlock and remove the padlock from the back of the system if a pad
69. CI slot 4 P4 64 bit PCI slot 5 P5 64 bit PCI slot 7 P7 64 bit PCI slot 8 P8 64 bit PCI slot 9 P9 64 bit PCI slot 6 P6 64 bit PCI slot 10 P10 Profusion carrier with four 65 W processors 46A 6 2A 28 5A Profusion carrier with four 65 W processors 46A 6 2A 28 5A Memory module 16 DIMMs 12 03 A Memory module 16 DIMMs 12 03 A 8 5 inch diskette drive 0 3 A CD ROM drive 1st SCA SCSI hard disk drive 2nd SCA SCSI hard disk drive Six cooling fans 49 A fan 12 V 0 4 A 1 0A Total Current SRPL8 Server System Product Guide gt NOTE The total combined wattage must be less than 1232 watts for your server 196 configuration The power must be less than e 201 watts for 3 3 V e 340 watts for 5 V e 672 watts for 12 V e 12 watts for 12 V e 2 4 watts for 24 V e 5 watts for 5 V standby Table 39 Total Combined Power Used by Your Server Voltage Level and Total Current V x A W 3 3 V 5 V 5 V 12 V 12 V 24 V x x x x x x A gt gt gt gt gt Total Watts for Each Voltage Level W zz lt
70. EMI shields covering the bays When you install a drive save the panel and shield to reinstall in case you should later remove the drive and not reinstall one in the same bay Bus termination when installing SCSI devices It is important that your cabling and connections meet the SCSI bus specification Otherwise the bus could be unreliable and data corruption could occur or devices might not work at all The SCSI bus needs to be terminated at the end of the cable this is usually provided by the last SCSI device on the cable For more information on connecting the data cable to a drive see step 9 on page 127 Observe the safety and ESD precautions at the beginning of this chapter Remove the peripheral bay see Removing the Peripheral Bay on page 117 Remove the drive from its protective wrapper and place it on an antistatic surface Record the drive model and serial numbers in your equipment log page 197 Set any jumpers or switches on the drive according to the drive manufacturer s instructions Using two screws of the appropriate size and length not supplied attach each plastic slide rail and its metal grounding plate to the drive NORD NE 126 Working Inside the System OM08013 Figure 41 Snap in Plastic Slide Rails A Tape drive or other removable media device B Tab on slide rail C Screws 4 D Slide rails 2 7 Position the drive so the plastic slide rails engage in the bay guide rails Push the drive
71. Initialized Press lt F2 gt to enter Setup If you do not press lt F2 gt and do NOT have a device with an OS loaded the above message remains for a few seconds while the boot process continues and the system beeps once Then this message appears Operating System not found To create software installation diskettes see the printed Quick Start Guide If you do not press lt F2 gt the boot process continues and this message appears Press lt Ctrl gt lt C gt to enter SCSI Utility Press lt Ctrl C gt if SCSI devices are installed When the utility opens follow the displayed instructions to configure the onboard SCSI host adapter settings and to run the SCSI utilities Also see Using the QLogic SCSI Utility on page 80 If you do not enter the SCSI utility the boot process continues Press lt Esc gt during POST to access a boot menu when POST finishes From this menu you can choose the boot device or enter BIOS Setup After POST completes the system beeps once What appears next on the screen depends on if you have an OS loaded on the server or which OS If the system halts before POST completes running it emits a beep code indicating a critical system error that requires immediate attention If POST can display a message on the video display screen the speaker beeps twice as the message appears 34 Configuration Software and Utilities Note the screen display and write down the beep code you hear this informati
72. Insert levers C Slide the tray from the chassis SRPL8 Server System Product Guide OM10709 105 Front Panel Controller Board The front panel board contains the server controls and indicators It is mounted on snap on and threaded standoffs on the profusion carrier tray Removing the Front Panel Controller Board See Figure 29 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the e Top cover see Removing the Top Cover on page 98 e Fan array housing see Removing the Fan Array Housing on page 101 e LCD module see Removing the LCD Module on page 102 3 Remove the insulating material from the front panel controller board 4 Remove the nine screws that attach the board to the chassis 5 Using even pressure slide the board straight toward the front of the chassis The connector attaching the board to the profusion carrier is at the left A in Figure 29 so be sure to pull the board STRAIGHT and not twist it A CAUTION When the front panel controller board is free of the profusion carrier tray connector its switches are surrounded by sheetmetal Be careful not to damage these switches when lifting the front panel board 6 Push pull the front panel board horizontally to free it from the profusion carrier connector and lift the board from the chassis 7 Place the board on a nonconductive static free surface or store it in an antistatic protective
73. Installing the LCD Module See Figure 27 1 Connect the LCD module data and power cables to the front panel board To attach the data cable insert the connector end of the cable into the connector on the front panel board This action causes the two levers on the board connector to close slightly When that happens push the levers together until the cable connector is fully seated in the board connector gt NOTE Verify that both cables are below the sheet of insulating material above the front panel board 2 Insert the tab on the left side of the LCD module into the slot and insert the screw on the right side of the module that you removed earlier and tighten it firmly 8 0 inch pounds 3 Install the fan array housing 4 Install the memory module cover OM10704 Figure 27 Removing the LCD Module A Memory module cover B LCD module SRPL8 Server System Product Guide 103 Profusion Carrier Tray The profusion carrier tray provides rigid mounting for the front panel board the profusion carrier and the memory modules It also facilitates mating the profusion carrier with the midplane Removing the Profusion Carrier Tray See Figure 28 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the e Top cover see Removing the Top Cover on page 98 e Memory module cover see Removing the Memory Module Cover on page 100 e Fan array housing see Remo
74. Min load Adc 0 00 0 00 0 00 10 000 0 00 0 00 0 00 Max load Adc 23 00 0 00 0 00 0 000 0 00 0 00 75 90 Max step load Adc 8 00 Peripherals SCSI backplane Min load Adc 0 00 0 70 025 0 000000 0 00 6 50 Max load Adc 0 00 4 50 5 99 0 000 0 00 0 00 94 38 Max step load Adc 0 90 5 40 Midplane Min load Adc Max load Adc 0 01 0 01 0 01 0 20 0 20 Total min load Ade 6 00 2 20 2 50 0 20 0 75 0 00 66 96 Total max step load Adc 20 00 14 00 28 00 0 25 0 25 0 05 Max step di dt A uS 0 50 1 00 0 60 0 10 0 10 0 05 Total max load Ade 66 00 51 44 62 40 1 21 1 00 0 20 Total load pwr 1246 32 W 217 8 257 2 748 80 14 52 5 3 1246 32 Total power includes 2 distribution loss 1271 24 i 1 Minimum load for second memory board is zero this assumes no board is installed 2 See Table 37 for definition of minimum and maximum configurations SRPL8 Server System Product Guide 193 Table 37 Minimum Maximum Current Rating Configurations Board Minimum Configuration Maximum Configuration VO carrier VO carrier I O riser board VO carrier I O riser board PCI adapter boards 10 at maximum load Profusion Profusion carrier processor mezzanine Profusion carrier processor mezzanine boards carrier board one Pentium III Xeon process
75. Options available in the dialog are e Power ON Powers on the server e Power OFF Powers off the server This option is not allowed if the server is configured in restricted mode for EMP operations e Post power up option Sets the server mode to EMP active or BIOS redirection The setting is effective at the next power up The default selection is EMP active e Cancel Exits the dialog with no action taken e Help Displays dialog level help information SRPL8 Server System Product Guide 69 Resetting the Server Remotely Select Reset from the Action Menu to generate the Reset dialog so that you can remotely reset the server with post reset options Operation Option Post reset option T System Reset EMP active Allow BIOS Re direct Cancel Help Figure 13 Reset Dialog Options available in the dialog are e System Reset Resets the server with the selected post reset options This operation is not allowed if the server is configured in restricted mode for EMP operations e Option Group Sets the post reset option that will be effective after reset The options are EMP active or BIOS redirection The default selection is EMP active e Cancel Exits the dialog with no action taken e Help Displays dialog level help information 70 Configuration Software and Utilities Phonebook The DPC console provides a phonebook a support plug in that stores names and numbers of servers in a list that can be updated
76. PL8 Server System Product Guide 107 Add In Boards The PHP VO carrier provides 10 PCI bus master slots CAUTION Do not overload the PHP I O carrier by installing add in boards that draw excessive current For expansion slot current limitations see Appendix A Power System Description Calculating Power Usage on page 191 Add in boards can be extremely sensitive to ESD and always require careful handling After removing the board from the protective wrapper or from the carrier place it component side up on a nonconductive static free surface Do not slide the board over any surface gt NOTE Running the SSU is optional for a PCI add in board Installing Replacing an Add In Board You can install an add in board when the server is operating or not operating The following procedure describes both scenarios The enhanced PCI hot plug EPHP mechanism is a rotating part that actuates a switch located on the EPHP board Each PCI slot has four indicator LEDs two on the outside and two on the inside of the system After the LED shows which slot is powered down you can press the EPHP mechanism on the actuator rotate the mechanism and remove the PCI board After a new PCI board is installed rotate the EPHP mechanism back into place to activate the switch and secure the board See Figure 30 page 109 and Figure 31 page 110 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2
77. Platz verf gen um Zugang zu den Netzkabeln zu gew hrleisten da der Stromanschlu des Produkts haupts chlich ber die Kabel unterbrochen wird SRPL8 Server System Product Guide 215 AVVERTENZA Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell alimentazione di questo prodotto E possibile che il prodotto disponga di pi fonti di alimentazione Non tentare di modificare o utilizzare il cavo di alimentazione in c a in dotazione se non esattamente del tipo richiesto Il pulsante di Accensione spegnimento della corrente continua sul sistema non interrompe l alimentazione in c a del sistema Per scollegare anche l alimentazione in c a necessario disinserire il cavo di alimentazione in c a dalla presa a muro o dall alimentatore PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema 3 Togliere tutte le spine dei cavi del sistema dalle prese elettriche 4 Identificare e sconnettere tutti i cavi attaccati ai collegamenti I O od alle prese installate sul retro del sistema 5 Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che attaccata alla
78. Processor See Figure 51 page 148 and Figure 52 page 149 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Remove the top cover see Removing the Top Cover on page 98 3 Remove the processor holddown and set it aside 4 Simultaneously rotate the eject insert levers of the processor cartridge outward to eject the cartridge out of the Slot 2 connector on the mezzanine board 5 Slide the cartridge out of the processor retention bracket slot guides and place it heat sink side up on a nonconductive static free surface or store it in an antistatic protective wrapper CAUTION If a Slot 2 connector is depopulated a termination module must be installed in the connector to properly terminate the signals on the FSB See Front Side Bus FSB Termination Board Assembly on page 150 OM10695 Figure 51 Removing a Processor Holddown A Processor holddown hook end B Captive screw 148 Upgrading Boardset Components Installing a Processor See Figure 51 page 148 and Figure 52 page 149 1 2 8 9 Observe the safety and ESD precautions at the beginning of this chapter To access the processor mezzanine board s follow the steps in Removing a Processor on page 148 Being careful not to touch the gold edge connector on the processor cartridge remove it from the protective wrapper Place the cartridge with the heatsink side up on a nonconductive static free surface Re
79. S rina dd 157 Monitoring POST illeso lare aaa 158 Verifying Proper Operation of Key System Lights nennen 158 Confirming Loading of the Operating System nn 158 Specific Problems and Corrective Actions 158 Power Light Does Not Light u ee nnee 159 ING Beep CodeS en ee se acted eee eat aaa 159 No Characters Appear on Screen 159 Characters Are Distorted or Incorrect i 160 System Cooling Fans Do Not Rotate Properly i 160 Diskette Drive Activity Light Does Not Light 160 Hard Disk Drive Activity Light Does Not Light 161 CD ROM Drive Activity Light Does Not Light 161 Network Problems eek Eaa R 161 PClilfstallation TIPS sonrie ati 161 Problems with Application Software 162 Bootable CD ROM Is Not Detected nnn 162 Error and Informational Messages 162 POST Codes and Countdown Codes 163 POST Error Codes and Messages sons Rie ae 167 SRPL8 Server System Product Guide vii 8 viii Technical Reference CONNECTIONS aller 172 Eisk tte Dive tata at tada titi 174 IRMG G0fnnecion sca rsa sata rada AS nie 175 VOA WOOO OM see ea 176 Keyboard and Mouse eh 176 Parallel Por a AAA 177 BER AL POMS A AN Br calli tias iena ili 177 Universal Serial Bus USB HH Hk 178 Soliana 178 Eee pi ito da i ei o alii o 179 A A TR ea 180 ES dt NAN de nn 182 General Procedure to Change Switch Settings 183 GMOS Cleat Wicca e
80. SRPL8 Server System Product Guide Order Number A49445 001 Disclaimer Intel Corporation Intel makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Intel assumes no responsibility for any errors that may appear in this document Intel makes no commitment to update nor to keep current the information contained in this document No part of this document may be copied or reproduced in any form or by any means without prior written consent of Intel An Intel product when used in accordance with its associated documentation is Year 2000 Capable when upon installation it accurately stores displays processes provides and or receives date data from into and between the twentieth and twenty first centuries including leap year calculations provided that all other technology used in combination with said product properly exchanges date data with it t Third party brands and names are the property of their respective owners Copyright 2001 Intel Corporation All rights reserved Contents Part l Users Guide 2 2 02 ies Ae ate eee o ee OG athe ae 11 1 Chassis Description Chassis Feature SUMMARY tiens in ee ee et 14 Chassis Front Controls and Indicators ua 15 Chassis Back Controls and Features 17 POMBO tal Sa ne aa zio a ee io if ri A del ilo arta Tt 18 3 5 inch Diskette Drive o 18 3 5 inch
81. ST Display Service Display prompt Press F2 to enter SETUP Disable cache Test RAM between 512 and 640k Test extended memory Test extended memory address lines Jump to UserPatch1 Configure advanced cache registers Initialize processors Enable external and processor caches Setup power management Display external cache size continued Solving Problems Table 16 Port 80 Codes continued POST Code 6B 6C 6E 70 72 74 76 7A 7C 7E 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8F 90 91 92 93 94 95 96 97 98 9A 9C 9D 9E Beeps 3 2 1 1 Error Load custom defaults Display shadow message Display nondisposable segments Display error messages Check for configuration errors Test real time clock Check for keyboard errors Test for key lock on Set up hardware interrupt vectors Test coprocessor if present Detect and install external RS232 ports Initialize run time devices Detect and install external parallel ports Configure IDE controller Initialize parallel port Initialize PC compatible PnP ISA devices Re initialize embedded I O ports Initialize embedded configurable devices Initialize BIOS Data Area Enable NMI Initialize Extended BIOS Data Area Initialize mouse Initialize floppy controller Preinitialize local bus hard disk controller Initialize hard disk controller or failure during MultiBoot Allocation Initialize local bus hard disk controller Jump to UserPatch2 Build MPT
82. SU console in VGA graphics mode e Control the mouse e Control the keyboard from a local system connected to a remote server by a network or modem The IRMC provides video memory keyboard and mouse redirection support Video memory and user input is sent to a remote location through either a modem or Ethernet link and displayed by the remote control console This solution requires an IRMC board installed in the remote server and the remote control software available on the local system In this model of remote operation the SSU executes exclusively on the remote server Any files required for the SSU to execute must be on the remote server on removable or nonremovable media Downloading the SSU toa remote server is not explicitly supported by the SSU but using a third party software package to download the required SSU files to the remote server is not prohibited BIOS Console Redirection Using BIOS console redirection you can e See the SSU console e Control the keyboard from a local system connected to a remote server by a modem or direct serial connection The local system must run terminal emulator software capable of supporting ANSI terminal sequences BIOS console redirection provides text mode video and keyboard redirection support only It does not support redirection of the mouse Text mode video and user input is sent to a remote location through either a modem or direct serial link and is displayed by the terminal emulato
83. T turn off the system AC power To remove power from system you must unplug ALL AC power cords from the wall outlet Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the system and disconnect all power cords telecommunications systems networks and modems attached to the system before opening it Otherwise personal injury or equipment damage can result 130 Upgrading Boardset Components AX CAUTIONS Electrostatic discharge ESD amp ESD protection ESD can damage disk drives boards and other parts We recommend that you do all procedures in this chapter only at an ESD protected workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your system when handling parts ESD and handling boards Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the system place it component side UP on a grounded static free surface Use a conductive foam pad if available but NOT the board wrapper Do not slide board over any surface Chassis covers proper cooling and airflow For proper cooling and airflow always install the chassis covers before turning on the system Operating the system without the covers in place can damage system
84. TI Rage XL specification for more details SRPL8 Server System Product Guide 189 190 Technical Reference A Power System Description Calculating Power Usage This appendix describes the modular power system and explains how to calculate power usage for your server A WARNING Only a QUALIFIED SERVICE TECHNICIAN is authorized to remove the server covers and to access any of the components inside the server Before removing the covers see Safety Before You Remove Server Covers on page 93 and Warnings and Cautions on page 94 Power System The modular power system for the server is provided by up to three 750 watt autoranging power supplies and a midplane The power system may be configured with two power supplies standard or three power supplies 2 1 redundant The power supplies are mounted in a 2 1 pattern in the back of the chassis along the bottom Each power supply has an integrated fan for cooling The midplane provides connectors for the hot swap power supplies The midplane also provides the interface logic for power supply related management functions such as e Power supply presence detection e Power supply fault signal reporting Care must be taken not to overload a branch circuit of the AC mains by plugging too many power cords into a single AC circuit We recommend plugging the power cord of the server into a separate circuit If a power supply fails in the redundant power system the yellow
85. Tighten the screws firmly between 4 0 and 6 0 inch pounds Position the drive in its opening in the front of the chassis on top of the CD ROM drive Slide the drive into the chassis until the frame of the carrier rests against the front of the chassis When positioned properly the tab on the left of the carrier mates with its corresponding slot in the chassis and the screw hole on the right of the carrier aligns with its corresponding hole in the chassis Secure the drive carrier assembly to the chassis with the screw you removed earlier tighten the screw firmly 6 0 inch pounds Connect the data and power cables to the drive Install the peripheral bay see Installing the Peripheral Bay on page 118 10 Run the SSU to specify that the diskette drive is installed in the system SRPL8 Server System Product Guide 125 Peripheral Drives Installing a 5 25 inch Peripheral in the Front Bay One 5 25 inch half height bay provides space for a tape backup CD ROM or other removable media drive CAUTIONS Do not install hard drives in 5 25 inch bays We recommend that you do NOT install hard drives in the 5 25 inch bays The drives cannot be properly cooled in this location also a hard drive generates EMI and is therefore more susceptible to ESD in this location lt gt NOTES Save the filler panels and EMI shields System EMI integrity and cooling are both protected by having drives installed in the bays or filler panels and
86. Use Area Internal Information Area Version 01h Length 104 End of the Fields in this Section Dislpay Chassis Area Chassis Information Area Version 01h Length 32 Chassis Type 11h Part Number ASCII SKCBS3501 Serial Number ASCII a of the Fields in this Section SITI Setup Utility Figure 8 FRU Manager Main Window Table 9 FRU Manager Menus Menu Options File Open FRU Opens FRU data from a previously saved file Exit Quits the FRU Manager View FRU Info Displays FRU information of the selected device All FRU Areas Displays FRU areas of all devices By Device Type Displays FRU areas sorted by device type Settings Display Hex Displays FRU areas in hex format Display Verbose Displays FRU areas in verbose format Output Text Saves FRU data in verbose format Output Binary Saves FRU data in binary format Help About Displays FRU Manager version information 62 Save FRU Saves FRU data to a file in binary raw or verbose text format Configuration Software and Utilities Exiting the SSU Exiting the SSU causes all windows to close 1 Exit the SSU by opening the menu bar item File in the SSU Main window 2 Click lt Exit gt Or Highlight Exit and press lt Enter gt Direct Platform Control DPC Console The DPC console provides an interface called the console manager to the EMP on the server This interface allows remote server management via a modem or direct co
87. _L 3 3V C BE1_L AD14 GND AD12 Pin B48 B49 B50 B51 B52 B53 B54 B55 B56 B57 B58 B59 B60 B61 B62 B63 B64 B65 B66 B67 B68 B69 B70 B71 B72 B73 B74 B75 B76 B77 B78 B79 B80 B81 B82 B83 B84 B85 B86 B87 B88 B89 B90 B91 B92 B93 B94 Signal AD10 M66EN 5V KEYWAY 5V KEYWAY AD8 AD7 3 3V AD5 AD3 GND ADI 5V ACK64 L 5V 5V RESERVED GND C BE6_L C BE4 L GND AD63 AD61 5V AD59 AD57 GND AD55 AD53 GND AD51 AD49 5V AD47 AD45 GND AD43 AD41 5V AD39 AD37 5V AD35 AD33 GND RESERVED RESERVED GND Technical Reference Table 28 66MHz 64 bit PCI Connectors Slots C and D Pin Al A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 A36 A37 A38 A39 A40 A41 A42 A43 A44 A45 A46 A47 Signal TRST_L 12V TMS TDI 5V INTA_L INTC_L 5V RESERVED 3 3V RESERVED 3 3V Keywa RESERVED RESET_L 3 3V GRANT_L GND RESERVED AD30 3 3V AD28 AD26 GND AD24 IDSEL 3 3V AD22 AD20 GND AD18 AD16 3 3V FRAME_L GND TRDY_L GND STOP L 3 3V SDONE SBO_L GND PAR AD15 3 3V AD13 AD11 Pin A48 A49 A50 A51 A52 A53 A54 A55 A56 A57 A58 A59 A60 A61 A62 A63 A64 A65 A66 A67 A68 A69 A70 A71
88. aining bracket must fit into the mating slot in the expansion slot frame Secure the add in board to the expansion slot frame using the power enabling switch actuator rotate the EPHP mechanism back into place and expansion slot cover retaining screw Connect any required cabling to the add in board If your server is not operating skip this step If your server is operating e Use the PCI hot plug utility to power up the PCI slot Reinstall the top and cover see Installing the Top Cover on page 99 Running the SSU is optional for a PCI add in board For information about running this utility see Using the System Setup Utility SSU on page 51 SRPL8 Server System Product Guide 109 Figure 31 Installing an Add in Board A Add In Board B EPHP Mechanism Working Inside the System Removing an Add In Board You can remove an add in board when the server is operating or not operating The following procedure describes both scenarios CAUTION 9 Expansion slot covers must be installed on all vacant slots to maintain the electromagnetic emission characteristics of the server and to ensure proper cooling of the server components Observe the safety precautions warnings and cautions at the beginning of this chapter Remove the PCI bus hot plug cover see Removing the PCI Bus Hot Plug Cover on page 97 Disconnect any cables attached to the board you are removing Remove
89. amount of resources to allocate to empty hot plug Min PCI slots Max Timeout on POST errors Disabled if enabled boots operating system after 5 seconds of Enabled displaying POST errors If disabled waits for user to press F1 or F2 PCI Configuration Selects PCI Configuration submenu I O Device Configuration Selects I O Device Configuration submenu Advanced Chipset Control Selects Advanced Chipset Control submenu SRPL8 Server System Product Guide 41 PCI Configuration Submenu Default values are in bold typeface Feature Option Description Processor Bus 100 MHz Displays the clock speed of the Processor Bus PCI Slots 1 2 PCI 33 Displays the clock speed and setting of PCI Segment A PCI Slots 3 6 PCI 33 Displays the clock speed and setting of PCI Segment B PCI Slots 7 8 PCI 33 Displays the clock speed and setting of PCI Segment C PCI 66 PCI X 66 PCI X 100 PCI Slots 9 10 PCI 33 Displays the clock speed and setting of PCI Segment D PCI 66 PCI X 66 PCI X 100 PCI Bus Default PCI 33 If no cards are present behind a PCI X capable bus this PCI 66 selects the capabilities of that empty bus If cards are PCI X 66 present this option is ignored and the slot speed is automatically determined PCI Device Embedded SCSI PCI Slot 1 PCI Slot 2 PCI Slot 3 PCI Slot 4 PCI Slot 5 PCI Slot 6 PCI Slot 7 PCI Slot 8 PCI Slot 9 PCI Slot 10 PCI Mode Submenu
90. an 14 hazardous conditions 94 hot swapping 88 input voltage ranges 19 input voltages 192 maximum watts drives 18 output voltage 192 redundant 88 removing 88 replacing 90 safety interlock mechanism 88 warning 88 power system 14 191 power usage calculating 194 worksheet 195 196 problems after running new application software 156 after system has been running correctly 156 application software 162 beep codes 159 bootable CD ROM not detected 162 CD ROM drive activity light 161 confirm OS loading 158 diskette drive light 160 hard drive light 161 initial system startup 155 network 161 no characters on screen 159 PCI installation tips 161 SRPL8 Server System Product Guide power light 159 preparing system for diagnostic testing 157 random error in data files 156 screen characters incorrect 160 system cooling fans do not rotate 160 system lights 158 using PCDiagnostics 157 processor 22 installing 149 removing 148 processor retention bracket installing 135 removing 134 profusion carrier 22 installing 136 removing 136 profusion carrier tray installing 104 removing 104 Q R QLogic SCSI boot time message 34 real time clock running SSU to configure settings 153 recovery mode indicator SCSI drive 87 regulatory specifications electromagnetic compatibility 208 safety compliance 207 removable media bays grounding clip 126 installing drive 126 installing drive slide rai
91. and save the screw securing the add in board to the expansion slot frame If your server is NOT operating skip this step If your server IS operating e Access the PHP GUI on the CD ROM that came with your server e Use the PHP GUI to power down the appropriate PCI slot Grasp the board by the top edge or upper corners and carefully pull it upward until the edge connector of the board pulls free from the connector on the PHP I O carrier Make sure that you do not scrape the board against other components Store the board in an antistatic protective wrapper Install an expansion slot cover see Figure 30 on page 109 over the vacant slot The tapered foot of the cover must fit into the mating slot in the bottom of the expansion slot frame Install the power enabling switch actuator over the vacant slot The spring at the end of the actuator rests on the power enabling switch 10 Secure the cover and actuator to the frame using the retaining screw 11 Reinstall the top cover see Installing the Top Cover on page 99 I O Riser Board Removing the I O Riser Board See Figure 32 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Verify that system power is OFF and that the AC power cord is removed from the back of the system and that all cables mouse keyboard etc are disconnected from the I O back panel 3 Remove the top cover and 240 VA protective covers see Removing the Top Cove
92. ard 1 Processor 4 Internal Error IERR failure 8230 Board 2 Processor 1 Thermal Trip failure 8231 Board 2 Processor 2 Thermal Trip failure 8232 Board 2 Processor 3 Thermal Trip failure 8233 Board 2 Processor 4 Thermal Trip failure 8234 Board 1 Processor 1 Thermal Trip failure 8235 Board 1 Processor 2 Thermal Trip failure 8236 Board 1 Processor 3 Thermal Trip failure 8237 Board 1 Processor 4 Thermal Trip failure 8240 Board 2 Processor 1 disabled 8241 Board 2 Processor 2 disabled 8242 Board 2 Processor 3 disabled 8243 Board 2 Processor 4 disabled 8244 Board 1 Processor 1 disabled 8245 Board 1 Processor 2 disabled 8246 Board 1 Processor 3 disabled 8247 Board 1 Processor 4 disabled 8250 Board 2 Processor 1 failed FRB Level 3 timer 8251 Board 2 Processor 2 failed FRB Level 3 timer 8252 Board 2 Processor 3 failed FRB Level 3 timer 8253 Board 2 Processor 4 failed FRB Level 3 timer 8254 Board 1 Processor 1 failed FRB Level 3 timer 8255 Board 1 Processor 2 failed FRB Level 3 timer 8256 Board 1 Processor 3 failed FRB Level 3 timer 8257 Board 1 Processor 4 failed FRB Level 3 timer 8260 Board 2 Processor 1 failed initialization 8261 Board 2 Processor 2 failed initialization 8262 Board 2 Processor 3 failed initialization 8263 Board 2 Processor 4 failed initialization 8264 Board 1 Processor 1 failed initialization 8265 Board 1 Processor 2 failed initialization 8266 Board 1 Pr
93. ard drive failure 4 Reinstall the bottom bezel by aligning the clips with the ball studs on the chassis and pushing the bezel onto the chassis 5 Reinstall the top bezel by aligning the ball studs with the clips on the chassis and pushing the bezel onto the chassis OM10705 Figure 20 Removing the Front Bezels A Bottom Bezel B Top Bezel SRPL8 Server System Product Guide 95 Removing and Installing Server Covers 96 See Figure 21 The server comes with several removable covers The fan array cover provides access to the 6 fan array The PCI bus hot plug cover provides assess to the PCI bus hot plug slots The top cover provides access to the profusion carrier I O carrier and 240 VA protective cover You must remove the top cover before you can remove the 240 VA protective cover The memory module cover provides access to the two memory modules CAUTION For proper cooling and airflow do not operate the server with the covers removed Always reinstall them before turning on the server D OM07514 Figure 21 Server Covers Memory module cover Fan array cover Top cover PCI hot plug cover vom Working Inside the System Removing the PCI Bus Hot Plug Cover See Figure 22 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove and save the screws that attach the PCI bus hot plug cover to the chassis 3 While facing the front of the server
94. ards System board PCI Host Bridge Device Bus 0 Dev 0 PCI SCSI Device Bus 0 Dev B PCI Ethernet Device Bus 0 Dev 10 PCI VGA Device Bus 0 Dev 12 PCI Multifunction Device Bus 0 Dev 14 SRPL8 Server System Product Guide 199 System board SSU Change Configuration Settings 200 Worksheet 2 Systems Group System Identification and Version Information SSU Configuration File Version MP Spec Version 1 1 1 4 Processor Speed Setting Worksheet 3 Memory Subsystem Group Onboard Disk Controllers Onboard Communication Devices Enable Disable Worksheet 4 Onboard Disk Controllers Onboard Diskette Controller Enable Disable Primary Onboard IDE Controller Enable Disable Secondary Onboard IDE Controller Enable Disable Worksheet 5 Onboard Communications Devices Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 2 Mode Parallel Port Configuration Parallel Port Mode Worksheet 6 Diskette Drive Subsystems Group Diskette drive A Options Diskette drive B Options Worksheet 7 IDE Subsystem Group IDE Configuration drive name Primary Master None User Auto CD IDE Drive Options 2 Sector Block 4 Sector Block 8 Sector Block 16 Sector Block Disable Primary Master Transfer Mode PIO1 PIO2 PIO3 PIO4 Primary Master IDE Configuration drive name Primary Slave None User Auto CD IDE Drive Options 2 S
95. ashing it indicates a fan failure G Drive fault LED yellow When lit continuously it indicates an asserted fault status on one or more hard disk drives in the hot swapping bay When flashing it indicates drive reset in progress H Front panel LCD Displays information about processor type and failure codes Status LEDs for SCSI Drives in Hot swapping Bays Drive power LED green When lit continuously it indicates the presence of the drive and power on the drive J Drive activity LED green Indicates drive activity K Drive fault LED yellow When lit continuously it indicates an asserted fault status on one or more hard disk drives in the hot swapping bay When flashing it indicates drive reset in progress Typical CD ROM Drive L Open close button When pressed it opens or closes the CD ROM tray M Activity LED When lit it indicates the drive is in use N Volume control It adjusts the volume of headphones or speakers O Headphone jack It provides a connection for headphones or speakers 3 5 inch Diskette Floppy Drive P Activity LED When lit it indicates the drive is in use Q Ejector button When pressed it ejects the diskette Chassis Description Chassis Back Controls and Features A BCD
96. ast 20 SCSI III SCA type hard drives The hard drives are externally accessible at the front of the system and connect to a wide LVDS hot swap SCSI backplane As part of the hot swap implementation a drive carrier with an integral heatsink is required The drives are mounted in the carrier with four fasteners and the carrier snaps into the chassis with a locking handle A single metal EMI shield and plastic door cover the drive bays A hot swapping bay is provided for drives that are 3 5 inches wide and 1 0 or 1 6 inches high Drives can consume up to 24 watts of power and must be specified to run at a maximum ambient temperature of 40 C 104 F 5 25 inch Removable Media Device Bay The peripheral bay has one 5 25 inch half height bay that is accessible from the front of the system This bay is intended to provide space for a tape drive for backup or for another removable device We recommend that you do not use this bay for a hard disk drive because hard disk drives generate EMI increasing ESD susceptibility and because of inadequate cooling Chassis Description Hot Swap Power Supplies The chassis can be configured with two or three 750 watt power supplies in a 2 1 redundancy configuration If you have three supplies installed you can hot swap a failed supply without affecting system functionality If you have two supplies installed they must occupy the left and center bays as you face the back of the server see Figure 3 on
97. au syst me 2 Mettez le syst me hors tension en mettant l interrupteur g n ral en position OFF bouton poussoir 3 D branchez tous les cordons d alimentation c a du syst me et des prises murales 4 Identifiez et d branchez tous les c bles reli s aux connecteurs d E S ou aux acc s derri re le syst me 5 Pour pr venir les d charges lectrostatiques lorsque vous touchez aux composants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Une fois TOUTES les tapes pr c dentes accomplies vous pouvez retirer les panneaux du syst me Proc dez comme suit 1 Si un cadenas a t install sur l arriere du syst me d verrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez les dans un endroit s r 8 Retirez les panneaux Afin de permettre le refroidissement et l a ration du syst me r installez toujours les panneaux du bo tier avant de mettre le syst me sous tension Le fonctionnement du syst me en l absence des panneaux risque d endommager ses pi ces Pour installer les panneaux proc dez comme suit 1 Assurez vous de ne pas avoir oubli d outils ou de pi ces d mont es dans le syst me 2 Assurez vous que les c bles les cartes d extension et les autres composants sont bien install s 3 Revissez s
98. blocks of data v Verbose display any additional details Copyright c 1998 Intel Corporation All Rights Reserved This utility must be run from a system executing DOS Running in a Window s DOS box is insufficient and will provide incorrect results Programming the BMC FRU area clears the SDR table therefore the SDR table must be reprogrammed Upon completing the programming of the FRU and SDR areas the server should be rebooted Note DOS users may alternatively use a instead of the The following information displays if the v option is included in the command line The D FRU command may be followed with up to 16 device addresses These devic addresses are used to view up to 16 different FRU areas instead of the default of displaying the BMC FRU The arguments following the d FRU are in the same order and value as the NVS_TYPE NVS_LUN DEV_CONTROLLER DEV_BUS and DEV_ADDRESS which are found in the FRU file header in each FRU file The LUN address and device controller are optional If the LUN address is used it must start with an L If the device controller is used it must start with a C and all other parameters must be present Usage FRUSDR d fru device devctrl lun bus addr addr2 etc Example FRUSDR D FRU IMBDEVICE C22 L00 00 CO C2 The configuration file can be used to load multiple FRU and SDR files In the configuration file
99. by adding modifying or deleting entries You can open the phonebook from the Main Menu and tool bars or launch it by clicking the Config button Phonebook X Server Po y Phone No _ Connect Operation Cancel New Modify Delete Help Figure 14 Phonebook Dialog Options available in the dialog are Server Displays a dropdown list of server names previously stored in the phonebook To clear the server field select New Phone No Displays the number of the selected server To clear the Phone No field select New Operation New Makes a new entry in the phonebook Selecting this option clears the Server and Phone No fields You must click lt Save gt to add the entry to the phonebook Modify Edits an existing entry First select an existing entry from the Server dropdown edit box and modify the existing phone number Click lt Save gt to store this entry Delete Deletes an entry from the phonebook You must first select an existing server from the Server dropdown edit box Click lt Save gt to delete the entry Save Saves a new or modified phonebook entry or deletes an entry if you have already selected the Delete radio button Connect Opens the Connect dialog with the server whose name appears in the phonebook s Server dropdown edit box Cancel Exits the dialog with no action taken Help Displays dialog level help information SRPL8 Server System Product Guid
100. cel Server Cancel COM Port No a Help Figure 11 Connect Dialog Options available in the dialog are e Line Selection Dial up Connects to the selected server with a dial up modem Direct connect Serial Line Connects to the selected server directly using a null modem serial cable e Server Displays a list of available servers in a dropdown edit list box You can select or enter a server name when the line selection is dial up you must select a server 68 Configuration Software and Utilities e Serial Line When the line selection is set to direct connect serial line you must specify the following Baud Rate Specifies baud rate must be 19200 for DPC to connect properly COM Port No Sets the COM port number to which the null modem serial cable is connected e Connect Initiates connection to the server When you click this button you are prompted for the EMP password e Config Displays the Phonebook dialog e Cancel Exit the Connect dialog with no action taken e Help Display dialog level help information Powering the Server On Off Remotely Select Power On Off from the Action Menu to power the server on or off with post power up options This option generates the Power on off dialog Power on off 3173 Operation Option CEE PotPonerup opion to E ME active Power DEF amp Allow BIGS Re direct Cancel Help Figure 12 Power On Off Dialog
101. cord the serial number of the cartridge in your equipment log page 197 Install processors sequentially beginning with the connector marked Processor 1 on the mezzanine board Grasp the cartridge by the eject insert levers A and carefully slide it into the slot guides of the processor retention bracket until the processor stops To seat the cartridge in the mezzanine board connector push down on the levers simultaneously making sure that the lever locks B engage with the slots of the processor retention bracket flange C Insert the hook end of the holddown bracket in the flange of the processor retention bracket Reinstall the holddown securing screw 10 Reinstall the top cover OM10693 Figure 52 Installing a Processor A Eject insert levers B Lever locks C Slot in processor retention bracket flange SRPL8 Server System Product Guide 149 Front Side Bus FSB Termination Board Assembly The profusion carrier provides connectors for two processor mezzanine boards Each board provides four Slot 2 connectors for Pentium III Xeon processors packaged in S E C cartridges If any Slot 2 connector is depopulated a termination board assembly must be installed in the connector to properly terminate the signals on the FSB For example if only two slots in a mezzanine board are populated with processors you need FSB termination board assemblies in the two unpopulated processor slots The assembly is a termination board
102. cription Configuration Software and Utilities Hot Swapping Fans SCSI Hard Drives and Power Supplies WARNING Only a QUALIFIED SERVICE TECHNICIAN is authorized to remove the server covers and to access any of the components inside the server Before removing the covers see Safety Before You Remove Server Covers on page 93 and Warnings and Cautions on page 94 This manual is divided into two parts User s Guide beginning on page 11 describes procedures that DO NOT REQUIRE internal server access You do not need to be a qualified service technician to perform procedures listed in the User s Guide Service Technician s Guide beginning on page 91 describes procedures that REQUIRE internal server access You must be a qualified service technician to perform procedures listed in the Service Technician s Guide NOTE The SRPL server system is an upgrade to the SRPM8 server system with PCI X features added The SRPL8 server system implements PCI 2 1 compliant buses with four PCI X enabled slots In this document the term PCT is loosely used to refer to PCI and PCI X features The term PCI X is limited to references to PCI X only 12 Part 1 User s Guide Chassis Description The SRPL rack server is easy to integrate and can easily accommodate the needs of a variety of high performance applications for example network servers multiuser systems and large database operations As your app
103. current stepping for Board 1 Processor 2 8176 BIOS does not support current stepping for Board 1 Processor 3 8177 BIOS does not support current stepping for Board 1 Processor 4 8180 PXB 1 Failed to respond 8181 Mismatch among Processors Detected 8182 L2 cache size mismatch 8200 Baseboard management controller failed to function 8201 Front panel controller failed to function 8202 Power Share Controller failed to function 8203 Hotswap Controller failed to function 8210 Board 2 Processor 1 failed BIST 8211 Board 2 Processor 2 failed BIST 8212 Board 2 Processor 3 failed BIST 8213 Board 2 Processor 4 failed BIST 8214 Board 1 Processor 1 failed BIST 8215 Board 1 Processor 2 failed BIST 8216 Board 1 Processor 3 failed BIST 8217 Board 1 Processor 4 failed BIST 8220 Board 2 Processor 1 Internal Error IERR failure 8221 Board 2 Processor 2 Internal Error IERR failure continued Solving Problems Table 17 POST Error Codes and Messages continued Code Error message 8222 Board 2 Processor 3 Internal Error IERR failure 8223 Board 2 Processor 4 Internal Error IERR failure 8224 Board 1 Processor 1 Internal Error IERR failure 8225 Board 1 Processor 2 Internal Error IERR failure 8226 Board 1 Processor 3 Internal Error IERR failure 8227 Bo
104. cy energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Electromagnetic Compatibility Notices International 208 CORBI HUES TAMS GEMS VCCI DEM BOSD SAAHREHEE CT CORBERERN CHATS CBR HSEUNAROTOEMHORT COMSAT SLIBRENSCEMBNET English translation of the notice above This is a Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment VCCI If this is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions Cet appareil num rique respecte les limites bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le Ministre Canadian des Communications English translation of the notice above This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Regulatory Specificiations D Warnings WARNING English US
105. d 45 SERVER MENU Son ee ee ee ee alan 46 BOOT MENU a eigen 49 Exit Men za o 50 Using the System Setup Utility SS Ulea elek 51 When to Run the SSU re Peace ee UT a eae eer di ed 51 What You Need to Do ee lee 52 Running he SSL ee eee a 52 Customizing the SSL ses te Aliso clones Seite he ates alte heared Gee Seco 55 La nchingia Task een een Nena 56 Resource Configuration Add In RCA Window 56 Multiboot Options Add IMi Hesse ee 57 Sec tity AIM ie eat tee nn Re areali e 57 System Event Log SEL Viewer Add In cnn 58 Sensor Data Record SDR Manager Add In 60 Field Replaceable Unit FRU Manager Add In 61 EXITO O LUO A cohen eae Matern ri 63 Direct Platform Control DPC Console 63 How the DPC Console Works a in nee er ek 63 DPC Console Requirements vestida rs ee era ee 65 Setting Up the Server for the EMP sr art 66 Main DPC Console Mini sn platanos ences iit tite hi talents ARS 67 Server Control Operations nine ln 68 Phonebooki dieta ilaele 71 ManagenentPlug InSrs 4 2 Feten arena ea 72 FRU and SBR Load Uti Golia iaia 72 When to Run the FRUSDR Load Utility ss 73 What You Need to DOS er he e leali ice NA ao i 73 How You Use the FRUSDR Load Utility latine iii ii 73 Cleaning Up ahd EXT O tia 76 Uparadna BIO Suu lilla o 77 Preparing tor the Upgrade dd 77 loja elo A ile are n ao ernment e A E T 78 Recovering BIOS r
106. diskette drive 16 lithium backup battery disposing of safely 152 installing 153 removing 152 memory 25 amount tested POST 34 as used by different operating systems 26 installing DIMM 145 removing DIMM 144 video size 27 memory map 186 memory module description 23 installing 142 removing 142 messages error and informational 162 mezzanine board s installing 135 removing 135 midplane installing 140 removing 140 mouse compatibility 28 inactivity timer 28 N P network problems with network 161 NMB 003 Class A limits 208 operating systems 21 parallel port location on I O carrier 177 password administrative 31 protection 31 retaining at system reset 184 user 31 using to reactivate keyboard mouse 28 PCI 21 bus master slots 108 configuration and device map 187 connectors on I O carrier 180 interrupt mapping 187 PCI bus hot plug covers installing 97 peripheral bay removing 117 118 peripheral bay backplane installing 120 removing 119 peripheral bay blind mate board installing 123 removing 121 PHP LED Board installing 114 removing 113 Index POST bootable media required 34 countdown codes 163 error codes and messages 167 error messages 34 memory amount tested 34 power cords disconnect all before opening system 94 130 power on off switch does not turn off AC power 93 94 130 power supply 14 configuration constraints 88 DC outputs 19 failure LED 88 f
107. disponga de mas de una fuente de alimentaci n No intente modificar ni utilizar el cable de alimentaci n de CA si no corresponde al tipo de cable exacto requerido El conmutador del bot n de comando de corriente continua del sistema no desactiva la alimentaci n de CA del sistema Para interrumpir la alimentaci n de CA del sistema debe desenchufar el cable de alimentaci n de CA de la toma de alimentaci n INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el interruptor encendido apagado 3 Desconecte todos los cables de alimentaci n CA del sistema o de las tomas de corriente alterna 4 Identifique y desconecte todos los cables enchufados a los conectores E S o a los puertos situados en la parte posterior del sistema 5 Cuando manipule los componentes es importante protegerse contra la descarga electrost tica ESD Puede hacerlo si utiliza una mu equera antiest tica sujetada a la toma de tierra del chasis o a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extra do las tapas del chasis Despu s de completar las seis instrucciones de SEGURIDAD mencionadas ya puede extraer las tapas del sistema Para ello 1 Desbloquee y extraiga el bloqu
108. drive Autotyped by BIOS Mode 1 Mode 2 SRPL8 Server System Product Guide 39 Processor Information Submenu Item Board 1 Processor 1 Stepping ID Board 1 Processor 1 L2 Cache Size Board 1 Processor 2 Stepping ID Board 1 Processor 2 L2 Cache Size Board 1 Processor 3 Stepping ID Board 1 Processor 3 L2 Cache Size Board 1 Processor 4 Stepping ID Board 1 Processor 4 L2 Cache Size Board 2 Processor 1 Stepping ID Board 2 Processor 1 L2 Cache Size Board 2 Processor 2 Stepping ID Board 2 Processor 2 L2 Cache Size Board 2 Processor 3 Stepping ID Board 2 Processor 3 L2 Cache Size Board 2 Processor 4 Stepping ID Board 2 Processor 4 L2 Cache Size Keyboard Features Submenu Default values are in bold typeface Description Displays the processor stepping Displays the L2 cache size Displays the processor stepping Displays the L2 cache size Displays the processor stepping Displays the L2 cache size Displays the processor stepping Displays the L2 cache size Displays the processor stepping Displays the L2 cache size Displays the processor stepping Displays the L2 cache size Displays the processor stepping Displays the L2 cache size Displays the processor stepping Displays the L2 cache size Feature Option Num Lock Auto On Off Description Selects power on state for Num Lock key Key Click Disabled Enabled Enables key click Keyboard auto repeat rate 30 sec 26 7 sec 21 8 sec 18 5
109. e 71 Management Plug Ins Field Replaceable Unit FRU Viewer The FRU viewer lets you view data from the server s FRU information area Options available with the FRU viewer are View all FRU records View FRU summary information Set FRU display mode to either hex or verbose mode Close the FRU viewer Exit the DPC console FRU Viewer Menu Options The following menu options are on the FRU viewer menu bar File Close Closes the FRU viewer Exit Exits the DPC console View Display all Records Displays all FRU data which consist of chassis board and product information FRU Info Displays the FRU summary information Settings Lets you change operating parameters for the FRU viewer This menu displays the following suboption Display Hex Verbose Toggles between hex mode and interpreted mode of displaying FRU records Window Gives options for displaying currently open windows Help Provides version information for the FRU viewer and provides help topics on the DPC console FRU and SDR Load Utility The Field Replacement Unit FRU and Sensor Data Record SDR load utility is a DOS based program that updates the server management subsystem s product level FRU SDR and the Desktop Management Interface DMI nonvolatile storage components EEPROMs The utility 72 Discovers the product configuration based on instructions in a master configuration file Displays the FRU informati
110. e ee 183 Password Clear Switch Fe een cae 184 Recovery Boot Swit h s este ee einen 184 System LO Add creta 185 MemoryMap SREE E ec etait ti wie ae en ee fase 186 PCI Configuration and Device Map ua ae ee 187 Inter Upis esc eisen dee Bean 187 Video Modes ana iaia ai 189 Power System Description Calculating Power Usage Power SV SUC IM i dae iaia eater 191 Power Supply Input Voltages ss 192 Power Supply Output Voltages ii lia 192 Server Current Usage estate eek 193 Calculating Power Usage acct nes an ed che aaa 194 Equipment Log and Configuration Worksheets Equipment Wo en RSR nn eee renee Cre rite er eri dio 197 Configuration Worksheals ee ae ne ee He 199 SOU Worksheets ee geile 199 Regulatory Specifications Regulatory and Environmental Specifications nennen 207 Environmental Specifications 207 Declaration of the Manufacturer or Importer nc nnnnnnne 207 Safety Compliance nina aa eater 207 Electromagnetic Compatibility EMC uusuuu24s444snnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 208 Contents D Warnings WARNING EndlishU Sicario ntc en a a ns Manette aay 210 AVERTISSEMENT Francais eolica ica ds ales anta 212 WARNUNG Dolls astas red ra ei rai G E 214 AVVERTENZA Al AO nee esse ee een 216 ADVERTENGIAS Espanol ee ee erh 218 INGE re ae 221 SRPL8 Server System Product Guide ix Contents Part I User s Guide A N a A Chassis Description Boardset Des
111. e following supporting files One or more fru files describing the system s FRUs A cfg file describing the system configuration An sdr file describing the sensors in the system Command Line Format The basic command line format is frusdr h d dmi fru sdr cfg filename cfg fru filename fru Table 12 Command Line Format Command Description Frusdr Is the name of the utility or h Displays usage information cfg filename cfg Uses custom CFG file Pause between blocks of data d dmi fru sdr Displays requested area only p SRPL8 Server System Product Guide 73 Parsing the Command Line The FRUSDR load utility allows only one command line function at a time A command line function can consist of two parameters Example cfg filename cfg Invalid parameters generate an error message and cause the program to end You can use either a slash or a minus sign to specify command line options The p flag can be used in conjunction with any of the other options Displaying Usage Information When the utility is run with the or h command line flags the following message is displayed when the verbose flag v is added to the help command FRU amp SDR Load Utility Version 2 1 Revision R 1 1 Usage Frusdr or h Displays usage information d dmi fru sdr Only displays requested area cfg filename cfg Uses custom CFG file p Pause between
112. e plastic mezzanine lock bars by simultaneously squeezing the winged protruding end of the lock bar and pulling out and away from the profusion carrier tray Carefully lift the processor retention bracket from the profusion carrier tray OM10654 Figure 44 Removing the Processor Retention Bracket A Profusion carrier tray B Metal latch verification bracket C Tab D Plastic mezzanine lock bars Upgrading Boardset Components Installing the Processor Retention Bracket See Figure 44 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Carefully align the processor retention bracket guideposts larger guide on the right with the bracket guides on the profusion carrier tray 3 Ensure that all the guides for each mezzanine board are properly aligned Lock the plastic mezzanine lock bars by squeezing the winged end of the plastic lock bar while simultaneously pushing in toward the profusion carrier tray Lock all four mezzanine lock bars 4 Push up and in on the metal latch verification brackets All four metal latches must be in the up position before reinstalling the profusion carrier tray Mezzanine Board s Removing and Installing Removing the Mezzanine Board s See Figure 45 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Remove the memory module page 142 3 Remove the profusion carrier tray page 104 4 Remove the processor retention bracket page 134
113. e profusion carrier requires that these filters be populated if the server has two processor mezzanine boards that are both populated with processors PHP I O carrier Ten hot pluggable 64 bit PCI expansion slots six 33 MHz PCI four 100 MHz PCI X Integrated ATI Rage XL graphics SVGA controller with 8 MB of video memory The QLogic 12160 Ultra 160 LVDS SCSI controller supports two LVDS channels One channel is used internally to provide support for the internal SCSI drives connected to the LVDS hot swap disk backplane and CD ROM or tape drive The second LVDS channel is routed to the rear of the chassis to support external devices The diskette controller supports one drive The PCl enhanced Integrated Drive Electronics IDE interface supports one IDE bus PS 2 compatible keyboard mouse controller Two universal serial bus USB ports I O riser board LVDS hot swap disk backplane This board contains all legacy I O connections it plugs into an edge connector on the PHP VO carrier PS 2 compatible keyboard and mouse ports interchangeable PS 2 compatible parallel port Analog VGA 15 pin video port Two PS 2 compatible 9 pin serial ports This backplane supports hot swapping of up to two SCA2 type SCSI drives mounted in carriers in and out of the hot swapping bays Front panel board The front panel board provides the user interface to the server The board allows other servers to communica
114. e system board Use the utility to e Change default values e Check and or change SCSI device settings that may conflict with those of other devices in the server Running the SCSI Utility When this message appears on the video monitor Press Ctrl C to start QLogic Configuration Utility Press lt Alt Q gt to run the utility When it appears choose the host adapter that you want to configure 80 Configuration Software and Utilities 4 Hot Swapping Fans SCSI Hard Drives and Power Supplies Tools and Supplies Needed e Phillips cross head screwdriver 2 bit e Antistatic wrist strap recommended e Penor pencil Equipment Log To record the model and serial numbers of the server all installed options and any other pertinent information about the server see Appendix B Equipment Log and Configuration Worksheets on page 197 You will need this information when running the SSU 81 Hot Swapping Fans When the yellow fan failure LED on the front panel turns on you can determine which fan is defective by checking each yellow fan failure LED mounted next to each fan When a fan fails the LED on the front panel will be on continuously You must hot swap the failed fan remove and replace it with a good one You DO NOT need to shut down the server to hot swap a failed fan A CAUTION Even though the server can continue operating with only five fans the defective fan must be replaced in a reasonable amoun
115. e the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the top and 240 VA protective covers see Removing the Top Cover on page 98 3 Disconnect the ICMB signal cable from its connector on the I O riser board 4 Remove and save the screw that attaches the ICMB board to the I O tray 5 Push on the tabs of the snap on standoff and pull the board toward the front of the chassis to remove it from the snap on standoff 6 Place the board on a nonconductive static free surface or store it in an antistatic protective wrapper Installing the ICMB Board See Figure 35 1 Remove the ICMB board from its protective wrapper 2 Position the board over the snap on and threaded standoffs on the I O tray 3 Press the board onto the snap on standoff and insert the screw loosely into the threaded standoffs 4 Make sure the board is properly aligned then tighten the screw firmly 8 0 inch pounds Connect the signal cable to its connector on the I O riser board 6 Reinstall the top and 240 VA protective covers see Installing the Top Cover on page 99 A OM07518 Figure 35 Removing the ICMB Board 116 Working Inside the System AC Filter and Cable Removing the AC Filter and Cable 1 D avo D Observe the safety precautions warnings and cautions at the beginning of this chapter Remove the midplane but leave it attached to its support bracket see Removing the
116. eck the following Is AC power available at the wall outlet Are the system power cords properly connected to the system and the wall outlet Did you press the power on off push button switch Is the power on light lit Have any of the fan motors stopped use the server management subsystem to check the fan status Are the fan power connectors properly connected to the front panel Are there any shorted open wires caused by pinched cables or power connector plugs forced incorrectly into sockets If the switches and connections are correct and AC power is available at the wall outlet contact your service representative or authorized dealer for assistance Diskette Drive Activity Light Does Not Light Check the following 160 Are the diskette drive power and signal cables properly installed Are all relevant switches and jumpers on the diskette drive set correctly Is the diskette drive properly configured Is the diskette drive activity light always on If so the signal cable may be plugged in incorrectly If you are using the onboard diskette controller use the SSU to make sure that Onboard Floppy is set to Enabled If you are using an add in diskette controller make sure that Onboard Floppy is set to Disabled To run the SSU see Chapter 3 starting on page 33 If the problem persists there may be a problem with the diskette drive I O carrier or drive signal cable Contact your service representati
117. ector Block 4 Sector Block 8 Sector Block 16 Sector Block Disable Primary Slave Translation Mode Standard CHS Primary Slave Logical Block Addressing Transfer Mode PIO 1 PIO2 PIO3 PIO4 Primary Slave Equipment Log and Configuration Worksheets Worksheet 8 Multiboot Group Boot Device Priority Diskette Drive Removable Devices Hard Drive ATAPI CD ROM Drive Diagnostic Boot Worksheet 9 Keyboard and Mouse Subsystem Group Typematic Delay 250 ms delay 500 ms delay 750 ms delay 1000 ms delay Typematic Speed 30 CPS other Mouse Control option Mouse Enabled Disabled Worksheet 10 Console Redirection COM Port for Redirection Port 3F8 IRQ4 Port 2F8 IRQ3 Port 3E8h IRQ 3 Disable Serial Port baud rate 9600 19 2k 38 4k 115 2k Hardware Flow Control None CTS RTS CTS RTS CD Xoff Xon Terminal Type PC ANSI VT 100 Worksheet 11 Security Subs Administrative Password User Password Secure Mode Hot Key Lockout Timer Secure Boot Mode Video Blanking Diskette Writes ystems Disable Enable Disable Enable None Ctrl Alt Disable minutes Disable Enable Disable Enable Disable Enable Reset Power Switch Locking Disable Enable Worksheet 12 SCSI ROM BIOS Options Group Onboard SCSI ROM BIOS scan Enable Disable Worksheet 13 Management Subsystem Group System Sensor Control Write
118. edures in this chapter only at an ESD protected workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your system when handling parts ESD and handling boards Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the system place it component side UP on a grounded static free surface If you place the VO carrier on a conductive surface the battery leads may short out If they do this will result in a loss of CMOS data and will drain the battery Use a conductive foam pad if available but NOT the board wrapper Do not slide board over any surface Cooling and airflow For proper cooling and airflow always install the chassis covers before turning on the system Operating the system without the covers in place can damage system parts 94 Working Inside the System Removing and Installing the Front Bezels See Figure 20 1 Use the finger grips to pull the bezels away from the chassis 2 Remove the bottom bezel to access the hot swap drives and the peripheral bay 3 Remove the top bezel to access the following e Front side of the fan bay e Front panel controller switches power reset and nonmaskable interrupt NMI and indicator lights power indicator predictive power supply failure predictive fan failure and h
119. ei ei 79 Changing BIOSTEAnguage std ee ie 79 Using the Firmware Update Utility ss 80 Running the Firmware Update Utility ss 80 Contents Installing Video DNV GIS ess ARS be noel dae 80 Using the QLogic S CSKU ee el 80 Running the SCSI Utility acli 80 4 Hot Swapping Fans SCSI Hard Drives and Power Supplies Tools and Supplies Need intarsi 81 o Rd ed io ui 81 H t Swapping Fans aerea 82 Hot Swapping a SCSI Hard Drive ana a nn aa dues tend 84 Hot Swapping Bay Site dopado ada aaa 84 SCSLSGA Hard Disk DINOS ns een 84 Hot Swapping Power Supplies siriana 88 H t Swapping a Power Supply u ee 88 Part Il Service Technician s Guide eeennnene 91 5 Working Inside the System Tools and S pplies NEGUS ics sr Reel 93 Safety Before You Remove Server Covers ss 93 Warnings and Gautions u ee 94 Removing and Installing the Front Bezels i 95 Removing and Installing Server Covers 96 Removing the PCI Bus Hot Plug Covers acc anise era a nee dut 97 Installing the PCI Bus Hot Plug Cover ea lari 97 Removing the Top CV u ee 98 Installing the TOP COVE scsi nhac dd 99 Removing the Memory Module Cover 100 Installing the Memory Module Cover 100 Fan Aftay HOUSING arena late aires ne 101 Removing the Fan Array Housing 101 Installing the Fan Array Housing ee 101 EGB M6dib ee EA E E EE caia 102 Removing the LCD Module 102 Installing the LCD Module ronca ei 103 Profusion Ca
120. emory module the preferred population order is to start from the lowest J number and populate sequentially to the highest This recommendation helps maintain optimal signal integrity and thermal performance NOTE Maximum capacity is limited to 16 GB with one memory module installed This increases to 32 GB with two modules Some OSs and application programs use base memory while others use both conventional and extended memory Examples e Base memory MS DOSt OS 2 Windows NTT and UNIXt e Conventional and extended memory OS 2 Windows NT and UNIX MS DOS does not use extended memory however some MS DOS utility programs like RAM disks disk caches print spoolers and windowing environments use extended memory for better performance BIOS automatically detects sizes and initializes the memory array depending on the type size and speed of the installed DIMMs and reports memory size and allocation to the system via configuration registers gt NOTE 26 DIMM sizes and compatibility Use DIMMs that have been tested for compatibility Contact your sales representative or dealer for a list of approved DIMMs Boardset Description Peripherals Super I O Chip The 37C937 Super I O device supports two serial ports one parallel port diskette drive and PS 2 compatible keyboard and mouse The system provides the connector interface for each port Serial Ports Both serial ports are relocatable By default port A is physical
121. eo de seguridad de la parte posterior del sistema si se ha instalado uno 2 Extraiga y guarde todos los tornillos de las tapas 3 Extraiga las tapas Para obtener un enfriamiento y un flujo de aire adecuados reinstale siempre las tapas del chasis antes de poner en marcha el sistema Si pone en funcionamiento el sistema sin las tapas bien colocadas puede da ar los componentes del sistema Para instalar las tapas 1 Aseg rese primero de no haber dejado herramientas o componentes sueltos dentro del sistema 2 Compruebe que los cables las placas adicionales y otros componentes se hayan instalado correctamente 3 Incorpore las tapas al chasis mediante los tornillos extra dos anteriormente tens ndolos firmemente 4 Inserte el bloqueo de seguridad en el sistema y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema contin a 218 Warnings ADVERTENCIAS Espa ol continua Si el sistema ha estado en funcionamiento el microprocesador y el disipador de calor pueden estar a n calientes Tambi n conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pila no se cambia de forma adecuada Utilice solamente pilas iguales o del mismo tipo que las recomendadas por
122. er 8160 Unable to apply BIOS Update for Board 2 Processor 1 continued SRPL8 Server System Product Guide 167 168 Table 17 POST Error Codes and Messages continued Code Error message 8161 Unable to apply BIOS Update for Board 2 Processor 2 8162 Unable to apply BIOS Update for Board 2 Processor 3 8163 Unable to apply BIOS Update for Board 2 Processor 4 8164 Unable to apply BIOS Update for Board 1 Processor 1 8165 Unable to apply BIOS Update for Board 1 Processor 2 8166 Unable to apply BIOS Update for Board 1 Processor 3 8167 Unable to apply BIOS Update for Board 1 Processor 4 8168 Board 2 Processor 1 L2 cache failed 8169 Board 2 Processor 2 L2 cache failed 816A Board 2 Processor 3 L2 cache failed 816B Board 2 Processor 4 L2 cache failed 816C Board 1 Processor 1 L2 cache failed 816D Board 1 Processor 2 L2 cache failed 816E Board 1 Processor 3 L2 cache failed 816F Board 1 Processor 4 L2 cache failed 8170 BIOS does not support current stepping for Board 2 Processor 1 8171 BIOS does not support current stepping for Board 2 Processor 2 8172 BIOS does not support current stepping for Board 2 Processor 3 8173 BIOS does not support current stepping for Board 2 Processor 4 8174 BIOS does not support current stepping for Board 1 Processor 1 8175 BIOS does not support
123. er outlet and the system power cords Solving Problems More Problem Solving Procedures This section provides a more detailed approach to identifying a problem and locating its source Preparing the System for Diagnostic Testing A CAUTION Turn off devices before disconnecting cables Before disconnecting any peripheral cables from the system turn off the system and any external peripheral devices Failure to do so can cause permanent damage to the system and or the peripheral devices 1 Turnoff the system and all external peripheral devices Disconnect all of them from the system except the keyboard and video monitor 2 Make sure the system power cords are plugged into a properly grounded AC outlet 3 Make sure your video display monitor and keyboard are correctly connected to the system Turn on the video monitor Set its brightness and contrast controls to at least two thirds of their maximum ranges see the documentation supplied with your video display monitor 4 Ifthe operating system normally loads from the hard disk drive make sure there is no diskette in drive A Otherwise place a diskette containing the operating system files in drive A 5 Turn on the system If the power LED does not light see Power Light Does Not Light on page 159 Using PCDiagnostics A diagnostics package for the system is contained on the configuration software CD ROM that comes with the system For documentation about the test modules
124. ery The lithium battery on the I O carrier powers the real time clock RTC for three to four years in the absence of power When the battery weakens it loses voltage and the system settings stored in CMOS RAM in the RTC e g the date and time can be wrong Contact your customer service representative or dealer for a list of approved devices A WARNING If the system has been running any installed processor and heat sink on the processor board s will be hot To avoid the possibility of a burn be careful when removing or installing components that are located near processors The following warning and translations are required by specific certifying agencies to be printed immediately adjacent to the procedure for removing the RTC A WARNING Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions A ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig handtering Udskiftning ma kun ske med batteri af samme fabrikat og type Lev r det brugte batteri tilbage til leverandgren A ADVARSEL Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres apparatleverandgren VARNING Explosionsfara vid felaktigt batteribyte Anvand samma batterityp eller en ekvivalent typ som rekommenderas av apparattill
125. estored after a CMOS clear for example you must run Setup again Referring to the worksheets could make your task easier If You Cannot Access Setup If the diskette drive is misconfigured so that you cannot access it to run a utility from a diskette you might need to clear CMOS memory You must open the system change a jumper setting use Setup to check and set diskette drive options and change the jumper back For a step by step procedure see CMOS Clear Switch on page 183 SRPL8 Server System Product Guide 35 Starting Setup You can enter and start Setup under several conditions When you turn on the system after POST completes the memory test When you reboot the system by pressing lt Ctrl Alt Del gt while at the DOS operating system prompt When you have moved the CMOS switch to the Clear CMOS position enabled for a step by step procedure see CMOS Clear Switch on page 183 In the three conditions listed above after rebooting you will see this prompt Press lt F2 gt to enter SETUP In a fourth condition when CMOS NVRAM has been corrupted you will see other prompts but not the lt F2 gt prompt Warning cmos checksum invalid Warning cmos time and date not set In this condition BIOS will load default values for CMOS and attempt to boot Setup Menus Setup has six major menus and several submenus 1 6 When you see this Main Menu e IDE submenu e Keyboard Features sub
126. ettings like screen colors cannot be saved The SSU supports the ROM DOS V6 22 OS It can run on other ROM DOS compatible OSs but they are not supported The SSU will not operate from a DOS window running under an OS like Windowst Running the SSU Remotely To run the SSU remotely you must use one of two mechanisms e Graphical hardware redirection through the Intel remote management card IRMC e BIOS console redirection gt NOTE 52 The SSU supports a text mode of operation versus the default VGA graphics mode Some forms of remote operation require that the SSU be operated in text mode In text mode the SSU screens are constructed using only character based graphics and colors The primary benefit of text mode is the reduced amount of display information that needs to be communicated to a remote console Support for text mode operation also allows the SSU to be operated remotely via modem using existing technologies with no modification to the SSU required To start the SSU in text mode type AF t from the command line in the SSU subdirectory the directory containing the af exe file Depending on the mode of execution this could involve exiting the SSU to reach the command prompt then restarting the SSU in text mode Configuration Software and Utilities Graphical Hardware Redirection through the Intel Remote Management Card IRMC Using graphical hardware redirection through the IRMC you can e See the S
127. ettings should remain the same EMP Password Any time you attempt to initiate a connection a prompt for the user password appears If you never set up the EMP password anyone can access the EMP by clicking lt OK gt through the password prompt In the EMP password area type in a password of up to eight alphanumeric characters If the system beeps the password was not accepted you must enter a different password EMP Access Modes Choose either disabled preboot or always active depending on the type of EMP access needed Tables 10 and 11 page 65 list what is available with a given setting EMP Restricted Mode Access Set restricted mode to either enabled or disabled In enabled mode the DPC console s server control options Power On Off and Reset are NOT available In disabled mode these options ARE available EMP Direct Connect Modem Mode Select Direct Connect if a null modem serial cable directly connects the server s COM2 port to the DPC console client machine If they are connected via a modem select Modem Mode Console Redirection Submenu 66 To use the EMP you must set the following options exactly as noted COM Port Address Select 2F8 This is the COM2 port that the EMP must use The IRQ setting is automatically assigned with the correct number based on the COM port address choice Baud Rate Select 19 2K Console Type Select PC ANSI Flow Control Select CTS RTS CD Configuration Software and Utilities
128. for the user to make use of the ISA bus The server boardset consists of a set of printed circuit boards e Profusion carrier Processor mezzanine board s Front side bus FSB terminator modules Cache coherency filters e PCI hot plug PHP I O carrier Low voltage differential SCSI LVDS hot swap disk backplane VO riser board e Two memory modules e Front panel controller board e Midplane The profusion carrier is mounted horizontally toward the front of the chassis and the PHP I O carrier is mounted horizontally towards the rear of the chassis The carriers plug into connectors on the midplane mounted between the two carriers The midplane interconnects the carriers with the memory modules and power supplies The front panel board is mounted in front of the profusion carrier in the same plane This board provides the user interface server management cooling system control and power control 21 OM07505 Figure 4 Boardset Overview A Front panel board B Profusion carrier C Processor mezzanine board D I O carrier E Midplane F Memory modules Boardset Features Table 4 Boardset Features Feature Profusion carrier Processor mezzanine boards Pentium III Xeon processor packaged in an S E C cartridge Description The profusion carrier provides the interface for processors via one or two processor mezzanine boards memory modules and cache coherency filters The pr
129. fusion Carrier and Processor Mezzanine Boards A B C D Processor mezzanine board Profusion carrier Mezzanine extraction tool cache hold down Grand connector PHP I O Carrier Removing and Installing A CAUTION The PHP I O carrier can be extremely sensitive to ESD and always requires careful handling After removing the carrier from the server place it component side up on a nonconductive static free surface to prevent shorting out the battery leads If you place the carrier on a conductive surface the back up battery leads may short out If they do this will result in a loss of CMOS data and will drain the battery Do not slide the carrier over any surface SRPL8 Server System Product Guide 137 Removing the PHP I O Carrier See Figure 46 Observe the safety and ESD precautions at the beginning of this chapter Remove the I O Tray see I O Tray on page 114 Remove the I O riser board see I O Riser Board on page 111 Remove the ICMB board see Interchassis Management Bus ICMB Board on page 116 Remove all power switch activators and covers Remove and save the screws that attach the PHP I O carrier to the tray Pull the carrier upward and unsnap it from the snap on standoffs Place the carrier on a nonconductive static free surface or store it in an antistatic protective wrapper RENA Dura Installing the PHP I O Carrier See Figure 46 1 Remove the PHP VO carrier from the antis
130. ghlight the function in the Configuration window 2 Press the spacebar or lt Enter gt or double click the entry this updates the choice and resource lists 3 Press the tab key to get to the choice list and press lt Enter gt Use the arrow keys to select a proper choice and press lt Enter gt again 5 Ifthe choice allows multiple possible values for a particular resource use the hot key to select a resource and press the spacebar or double click the resource 6 Select the desired resource and click lt OK gt gt System Resource Usage Click lt Resource Use gt in the Configuration window to display the System Resource Usage window which shows the resources each device consumes This information is useful if a conflict occurs Devices can be organized according to the resources you want to examine using the options in the Resource section of the screen The resource information can also be written to a plain text file through this window Multiboot Options Add In In this window you can change the boot priority of a device 1 Select a device 2 Press lt gt to move the device up in the list higher priority Press lt gt to move it down Security Add In In this window you can set the user and administrator passwords and security options To Set the User Password 1 Click lt User Password gt 2 Enter the password in the first field 3 Confirm the password by entering it again in the second field
131. he Memory Module Cover and Memory Module A Memory module cover Installing the Memory Module Cover 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Place the cover in position 3 Attach the cover to the chassis with the screws you removed earlier 100 Working Inside the System Fan Array Housing Removing the Fan Array Housing See Figure 26 page 102 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the following e Top cover see Removing the Top Cover on page 98 e Fan array assembly cover and all fans see Hot Swapping Fans on page 82 e Memory module cover see Removing the Memory Module Cover on page 100 Remove and save the three screws that secure the fan housing to the chassis 4 Use the frame of the housing the space the individual fans occupied as a handle to remove the housing e Tip the fan assembly forward e Slide the alignment pins free from the front edge of the profusion carrier e Pull the housing straight up away from the chassis then set it aside Installing the Fan Array Housing 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Reinstall the fan array housing ensuring that it engages with the support tabs A in Figure 26 amp NOTE When installing the fan array housing be careful not to accidentally move the thin sheet of i
132. he beginning of this chapter 2 Position the peripheral bay so that it rests on the bottom of the chassis with the drives facing the chassis front 3 Using the profusion carrier support as a handle slide the peripheral bay straight inward toward the center of the chassis 4 Use even pressure to mate the connector on the back of the peripheral bay on the peripheral bay backplane to the blind mate board in the chassis 5 Install the four screws removed earlier 6 Install the memory module cover see Installing the Memory Module Cover on page 100 OM07508 Figure 36 Peripheral Bay Working Inside the System Peripheral Bay Backplane Removing the Peripheral Bay Backplane See Figure 37 1 2 NND Observe the safety precautions warnings and cautions at the beginning of this chapter Remove SCSI drives from peripheral bay see Hot Swapping a SCSI Hard Drive on page 84 Remove peripheral bay see Removing the Peripheral Bay on page 117 Label and disconnect the diskette and CD ROM power and data cables from the backplane Remove and save the eight screws that attach the backplane to the peripheral bay Lift the backplane straight up and away from the peripheral bay Place the board on a nonconductive static free surface or store it in an antistatic protective wrapper SRPL8 Server System Product Guide 119 Installing the Peripheral Bay Backplane See Figure 37 1 Remove the b
133. he board on a nonconductive static free surface or store it in an antistatic protective wrapper SRPL8 Server System Product Guide 121 OM10701 Figure 38 Peripheral Bay Blind Mate Board A Screws two Working Inside the System 122 OM10708 Figure 39 Peripheral Bay Blind Mate Board Cables A Blind Mate connector header 20 pin power connector Wide SCSI connector 40 pin IDE connector 34 pin header floppy Moo Ww Installing the Peripheral Bay Blind Mate Board See Figure 38 1 Remove the board from its protective wrapper 2 Position the board against its support in the chassis then attach it with the four screws you removed earlier 3 Connect all previously removed cables to the board 4 Install the peripheral bay see Installing the Peripheral Bay 5 Install the profusion carrier tray see Installing the Profusion Carrier Tray on page 104 SRPL8 Server System Product Guide 123 Diskette Drive Removing the Diskette Drive See Figure 40 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Remove the peripheral bay see Removing the Peripheral Bay on page 117 3 Remove retaining screw at the front side of the diskette drive gt NOTE Cabling for Diskette and CD ROM Dr
134. he interface for 3 5 and 5 25 inch media It can support e One 5 25 inch IDE CD ROM drive in the 5 25 inch half height bay Optional any IDE or single ended SCSI device like a tape drive e Two 3 5 inch wide by 1 0 or 1 6 inch hot swappable low voltage differential SCSI LVDS hard disk drives mounted side by side in the 3 5 inch hot swapping bays These bays allow hot swapping of hard disk drives without shutting down the server Ten hot plug PCI I O expansion slots six 33 MHz PCI four 100 MHz PCI X The plastic front bezel provides airflow and easy access to drives in the hot swapping bays The removable top covers provide proper airflow and easy access to components inside the server Only technically qualified personnel should remove the server covers Cooling system with redundancy Six fans 5 1 cool and circulate air through the server The sixth fan is redundant The fans can be replaced hot swapped without turning off server power An LED indicator mounted next to each fan guarantees positive identification of the failed fan Integrated power supply fans two or three cool and circulate air through the power supplies and the bottom of the chassis Server management Interintegrated circuit bus 1 C for diagnostic and intrachassis communication Interchassis management bus ICMB for interchassis platform management communications Real time clock calendar RTC Front panel controls and indicato
135. hen enabled use the baud rate specified The maximum Rate 19 2K baud rate supported by the Emergency Management Port is 38 4 K 19 2K 115 2K Flow Control No Flow Control When enabled use the flow control type specified CTS RTS XON XOFF Configuration Software and Utilities Boot Menu Boot Menu options allow the user to select the boot device The following table shows an example list of devices ordered in priority of the boot invocation Items can be reprioritized by using the Up and Down arrow keys to select the device Once the device is selected use the plus key to move the device higher in the boot priority list Use the minus key to move the device lower in the boot priority list Feature Option Description Floppy Check Disabled Disabled speeds up the boot process Enabled Enabled verifies the floppy type on boot Boot Device Priority Selects the Boot Device Priority submenu Hard Drive Po Selects the Hard Drive submenu Removable Selects the Removable Devices submenu Devices Removable Format Selects the Removable Format submenu Maximum Number 1 Selects the maximum number of 1 0 drives that will be of 1 0 Drives 4 assigned a DOS drive Message Timeout 1 All 1 0 message timeout values are multiplied by this Multiplier 2 number 4 Pause During Disabled Use this to start the IRTOS 1 0 Real time Operating POST Enabled System manually When POST has stopped it issues three beeps Press
136. in these bays The power supply fans provide cooling for the hot swap drives A system with two power supplies is capable of cooling most drives that would be installed into the system However drives that dissipate a large amount of power might require three power supplies to ensure proper cooling See the product specifications to determine if the particular drive to be installed needs the additional cooling provided by a third power supply Carriers for 3 5 inch wide 1 inch or 1 6 inch height drives allow easy hot swapping of drives in and out of these bays without shutting down the server You can easily set up RAID applications if you install a Redundant Array of Inexpensive Disks RAID controller board on the PHP I O carrier RAID software and SCSI hard disk drives in the hot swapping bays SCSI SCA Hard Disk Drives The server supports a variety of single ended SCSI SCA type hard disk drives As shipped from the supplier the server might not contain any drives Contact your sales representative or dealer for a list of approved drives that can be installed in the server Mounting a SCSI SCA Hard Disk Drive in a Carrier See Figure 16 and Figure 17 page 85 1 Remove the 3 5 inch hard disk drive from the protective wrapper and place it on an antistatic surface 2 Record the model and serial numbers of the drive in your equipment log 3 Orient the drive carrier so that the handle is toward your left and the metal EMI ESD finger
137. ing bays monitor the status of each drive When a yellow LED is on continuously it is okay to hot swap remove and replace a bad drive with a good one You DO NOT need to shut down the server to hot swap a drive Table 13 SCSI Drive Status LED Descriptions SCSI drive present SCSI drive SCSI drive power on active faulty Green LED A Green LED B Yellow LED C Description and action if needed O O Drive is present with power On Off Off O O Drive is present with power and is being n n n accessed On Blinking Off 0 Drive CAN be replaced Steady yellow fault n n light indicates drive has a problem Power to Off Off On drive is off O ES o Drive SHOULD NOT be replaced at this time ES ma a A slowly blinking yellow fault light indicates that On Off Slow blinking a drive that has just been replaced is in recovery mode drive array being rebuilt Power to drive is on There is no drive installed in the bay En ES pau Off Off Off The hot swap controller is responsible for turning the yellow drive fault LED on or off according to the states specified by commands received via SAF TE and IMB 1 Look at the yellow LEDs below the hot swapping bays to determine which drive is bad Push on the drive carrier latch of the bad drive and while grasping the handle pull the assembly toward you to disengage the drive from the backplane connector 3 Before moving the drive any further wait 30
138. ing steps explain how to upgrade BIOS Creating a Bootable Diskette 1 Use a DOS or Windows 95 system to create the diskette 2 Insert a diskette in drive A 3 At the C prompt for an unformatted diskette type format a s or for a formatted diskette type sys a 4 Press lt Enter gt SRPL8 Server System Product Guide 77 Creating the BIOS Upgrade Diskette The BIOS upgrade file is a compressed self extracting archive that contains the files you need to upgrade 1 Copy the BIOS upgrade file to a temporary directory on your hard disk 2 From the C prompt change to the temporary directory 3 To extract the file type the name of the BIOS upgrade file for example 10006BI1 EXE 4 Press lt Enter gt The extracted file contains the following files LICENSE TXT README TXT BIOS EXE 5 Read the LICENSE TXT file which contains the software license agreement and the README TXT file which contains the instructions for the BIOS upgrade 6 Insert the bootable diskette into drive A 7 To extract the BIOS EXE file to the diskette change to the temporary directory that holds the BIOS EXE file and type BIOS A 8 Press lt Enter gt 9 The diskette now holds the BIOS upgrade and recovery files Upgrading BIOS 1 AAA 10 11 12 13 14 78 Boot the computer with the diskette in drive A The BIOS upgrade utility screen appears Select Update Flash Memory From a File Select Update Syste
139. initialize FRB 2 watch dog timer failed reset will occur in five seconds Solving Problems POST Error Codes and Messages The following error codes and messages are representative of various conditions BIOS identifies The exact strings and error numbers may be different from those listed here Table 17 POST Error Codes and Messages Code Error message 0200 Failure Fixed Disk 0210 Stuck Key 0211 Keyboard error 0213 Keyboard locked Unlock key switch 0220 Monitor type does not match CMOS Run SETUP 0230 System RAM Failed at offset 0231 Shadow RAM Failed at offset 0232 Extended RAM Failed at offset 0250 System battery is dead Replace and run SETUP 0251 System CMOS checksum bad Default configuration used 0260 System timer error 0270 Real time clock error 0280 Previous boot incomplete default configuration used 0281 Memory size found by POST differed from EISA CMOS 0297 Extended memory error 02B0 Diskette drive A error 02B1 Diskette drive B error 02B2 Incorrect Drive A type run SETUP 02B3 Incorrect Drive B type run SETUP 020 System cache error Cache disabled 02F0 CPU ID _02F4 EISA CMOS not writeable 02F5 DMA Test Failed 02F6 Software NMI Failed 02F7 Fail safe timer NMI failed 8108 Watchdog Timer failed on last boot 8110 Server Management Interface filed to function 814B BMC in Update Mode 8150 NVRAM Cleared By Jumper 8152 ESCD Data Cleared 8153 Password Cleared By Jump
140. is chapter Remove the top cover see Removing the Top Cover on page 98 Remove the Non Hot Plug cover by inserting thumb and forefinger into the two holes on the top of the cover then carefully lift up it up Disconnect Plug P2 from the PHP LED board Press and rotate all PHP switches to the open position To free the board from the chassis pull out and disengage the five plastic retaining pins OM08780 Figure 33 PHP LED Board A PHP LED board B Retaining pin C PHP LED cable SRPL8 Server System Product Guide 113 Installing a PHP LED Board See Figure 33 1 ABS Carefully position the PHP LED board by aligning each of the five plastic retaining pins to their corresponding positions on the chassis Once aligned push in the five plastic retaining pins locking the PHP LED board into position Connect Plug P2 to the PHP LED board Replace the Non Hot Plug cover Replace the top cover see Installing the Top Cover on page 99 I O Tray The I O tray provides rigid mounting for the PHP I O carrier and facilitates mating the I O carrier with the midplane Removing the I O Tray 114 See Figure 34 1 2 oo our E Oa Observe the safety precautions warnings and cautions at the beginning of this chapter Verify that system power is OFF and that the AC power cord is removed from the back of the system Remove the top and 240 VA protective covers see Removing the Top Cover on page 98
141. iskette drive is installed does its activity light turn on briefly If not see Diskette Drive Activity Light Does Not Light on page 160 If there is a hard disk drive or SCSI device installed in the system does the hard disk drive activity light on the control panel turn on briefly If not see Hard Disk Drive Activity Light Does Not Light on page 161 Confirming Loading of the Operating System Once the system boots up the operating system prompt appears on the screen The prompt varies according to the operating system If the operating system prompt does not appear see Initial System Startup on page 155 Specific Problems and Corrective Actions This section provides possible solutions for these specific problems Power light does not light No beep or incorrect beep pattern No characters appear on screen Characters on the screen appear distorted or incorrect System cooling fans do not rotate Diskette drive activity light does not light Hard disk drive activity light does not light CD ROM drive activity light does not light Problems with application software The startup prompt Press lt F2 gt key if you want to run Setup does not appear on the screen The bootable CD ROM is not detected Try the solutions in the order given If you cannot correct the problem contact your service representative or authorized dealer for assistance 158 Solving Problems Power Light Does Not Light Check
142. ives You cannot remove the diskette drive from the chassis by simply removing its cables from the peripheral bay backplane The diskette drive power cable attaches to the back of the CD ROM drive A power cable for both drives exits the CD ROM and connects to the peripheral bay backplane Therefore you must remove cables from the drives themselves to remove a particular drive 4 Disconnect the power and data cables from the diskette drive 5 Pull the diskette drive forward and out of the peripheral bay A Screw attaching the drive carrier assembly to the chassis B Screws attaching the carrier to the drive OM07360 Figure 40 Removing the Diskette Drive 124 Working Inside the System 6 qe 8 Place the drive carrier assembly component side up on an antistatic surface Remove and save the screws that hold the carrier to the drive Place the drive in an antistatic protective wrapper Installing the Diskette Drive 1 SI 8 9 Remove the new 3 5 inch diskette drive from its protective wrapper and place it component side up on an antistatic surface Record the drive model and serial numbers in your equipment log see page 197 Set any jumpers or switches according to the drive manufacturer s instructions Place the drive carrier on the noncomponent side of the drive and align the mounting holes Attach the carrier to the drive with screws of the appropriate size and length reuse the screws you removed before
143. kes Secure Mode Ctrl Alt X X A Z Secure Mode Boot Disabled Enabled system boots in the secure mode Requires a Enabled password to unlock the system Video Blanking Disabled Blank video when Secure Mode is activated Requires a Enabled password to unlock the system Floppy Write Protect Disabled When Secure Mode is activated the floppy drive is write Enabled protected Requires a password to re enable floppy writes Front Panel Lockout Disabled When Secure Mode is activated the Reset and Power Enabled switches are locked Requires a password is required to unlock the system SRPL8 Server System Product Guide 45 Server Menu 46 Default values are in bold typeface Feature Option Description System Management Selects System Management submenu Console Redirection Selects Console Redirection submenu No Yes Disabled Enabled Processor Retest EMP Password Switch EMP Password EMP ESC Sequence EMP Hangup Line String Modem Initialization String Select Yes to clear historical processor status and retest all processors on the next boot Enables the EMP password Selects the EMP password Updated from the Front Panel Controller firmware Updated from the Front Panel Controller firmware Updated from the Front Panel Controller firmware High Modem Initialization String EMP Access Mode Preboot Only Always Active Disabled Disabled Enabled EMP Res
144. kplane nn 120 Peripheral Bay Blind Mate Board 121 Removing the Peripheral Bay Blind Mate Board 121 Installing the Peripheral Bay Blind Mate Board 123 Diskette Drive ne tn at tt area 124 Removing the Diskette Drive ee are 124 Installing the Diskette Drive i 125 Peripheral Drives ae anses ie ee 126 Installing a 5 25 inch Peripheral in the Front Bay 126 Removing a 5 25 inch Peripheral from the Front Bay 0ooooccccccnoccnoccccccconananancccncnannnos 128 Upgrading Boardset Components T ls and S pplies Neededin ar seen a iR 129 Warnings and Cautions tesis Mien taste as 130 Cache Coherency Filters Removing and Installing i 132 Removing the Cache Coherency FIlters nnnnnnnnnnnn nennen 132 Installing the Cache Coherency Filters 133 Processor Retention Bracket Removing and Installing i 134 Removing the Processor Retention Bracket 134 Installing the Processor Retention Bracket ccccceesss seceeeeeeeeeeeeeeeessssneeeeeeees 135 Mezzanine Board s Removing and Installing nennen 135 Removing the Mezzanine Board s nn nccnnnnnos 135 Installing the Mezzanine Board s 135 Profusion Carrier
145. lication requirements increase you can upgrade your server with e More powerful and or additional processors e An additional processor mezzanine carrier with cache coherency filters e An additional memory module and additional memory e Other peripheral devices e Add in I O boards Table 1 Server Physical Specifications Specification Value Height 31 12 cm 12 25 inches 7u Width 44 45 cm 17 5 inches Depth 71 12 cm 28 0 inches Weight 51 4 kg 113 lbs minimum configuration 60 kg 132 lbs maximum configuration 10 inches inlet airflow lt 35 C 95 F 8 inches no airflow restriction Required front clearance Required rear clearance OM08751 Figure 1 SRPL8 MP Server Chassis Feature Summary 14 Table 2 Chassis Feature Summary Feature Comment Power system with redundancy The 750 watt 220 VAC autoranging power supplies include integrated fans for cooling When the server is configured with three supplies 2 1 the third provides redundancy The supplies can be replaced hot swapped without turning off server power The server requires a minimum of two power supplies LEDs on the back of the power supply indicate power on failure and predictive failure Server chassis The electrogalvanized metal used in manufacturing the server chassis minimizes electromagnetic interference EMI and radio frequency interference RFI The peripheral bay provides t
146. lity Use to access and monitor the server remotely 63 Use to update the Field Replacement Unit FRU Sensor Data Record SDR and Desktop Management Interface DMI flash components Use to update BIOS or recover from a corrupted BIOS update Use to update the BMC flash PROM Use to configure or view the settings of the SCSI host adapters and onboard SCSI devices in the system 33 Hot Keys Use the keyboard s numeric pad to enter numbers and symbols Table 6 Hot Keys To do this Press these keys Clear memory and reload the operating lt Ctrl Alt Del gt system this is a system reset Secure your system immediately lt Ctrl Alt gt hotkey Set your hot key combination with the SSU or Setup Enter BIOS Setup during BIOS POST F2 Abort memory test during BIOS POST ESC Press while BIOS is updating memory size on screen Power on Self Test POST Each time you turn on the system POST starts running POST checks the carriers processors memory keyboard and most installed peripheral devices During the memory test POST displays the amount of memory it is able to access and test The length of time needed to test memory depends on the amount of memory installed POST is stored in flash memory 1 2 Turn on your video monitor and system After a few seconds POST begins to run After the memory test these screen prompts and messages appear Keyboard Detected Mouse
147. lock has been installed 2 Remove and save all screws from the covers 3 Remove the covers For proper cooling and airflow always reinstall the chassis covers before turning on the system Operating the system without the covers in place can damage system parts To install the covers 1 Check first to make sure you have not left loose tools or parts inside the system 2 Check that cables add in boards and other components are properly installed 3 Attach the covers to the chassis with the screws removed earlier and tighten them firmly 4 Insert and lock the padlock to the system to prevent unauthorized access inside the system 5 Connect all external cables and the AC power cord s to the system continued 210 Warnings WARNING English continued A microprocessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions The system is designed to operate in a typical office environment Choose a site that is e Clean and free of airborne particles other than normal room dust e Well ventilated and away from sources of heat including direct sunligh
148. ls 126 installing metal EMI shield over empty bay 128 limiting use of hard drives 126 removing drive 128 routing cables 127 reset system 34 155 RFI 14 RTC See real time clock 225 S safety compliance 207 guidelines 93 SCI files 51 SCSI bus termination requirements 28 126 hard disk drive 84 indicator drive in recovery mode 87 installing in hot swapping bay 86 status indicators 87 hot swapping backplane 23 hot swapping bays 84 QLogic SCSI utility 80 singled ended devices 84 type of devices supported 28 wide input connector 178 secure mode using hot keys to enter 34 security 31 BIOS setup 31 boot sequence control 31 boot without keyboard 32 diskette write protect 32 emergency management port 32 locked power and reset switches 32 locking mouse keyboard with timer 28 password protection 31 secure boot mode 31 system setup utility SSU 31 using hot key combination 34 video blanking 32 serial port connectors on I O carrier 177 server boardset 21 chassis 14 cooling and airflow 96 management 14 server management features 29 service no user serviceable parts power supply 94 Setup cannot enter need to reconfigure diskette 35 changing configuration 33 description 36 recording settings 35 summary main menus 36 worksheet advanced menu 204 worksheet boot device priority 206 worksheet boot menu 206 worksheet I O Device Configuration submenu 205 workshee
149. ly the left connector as you look at the back of the system see Figure 3 on page 17 port B the right connector Each serial port can be set to one of four different COMx ports and each can be enabled separately When enabled each port can be programmed to generate edge or level sensitive interrupts When disabled serial port interrupts are available to add in boards Parallel Port The 25 15 pin connector stacks the parallel port over the VGA The 37C937 provides one IEEE 1284 compatible 25 pin bidirectional EPP supporting levels 1 7 and 1 9 BIOS programming of the Super I O registers enables the parallel port and determines the port address and interrupt When disabled the interrupt is available to add in boards Add In Board Slots The I O carrier has ten 64 bit PCI buses contained in four PCI segments e PCI A provides for PCI slots 1 and 2 33 MHz dual channel LVDS SCSI controller video and PITX4E The PIIX4E controls communications to IDE onboard ISA USB and Super I O for handling the keyboard mouse diskette drive parallel port and serial ports e PCI B provides for PCI slots 3 through 6 33 MHz e PCI C provides for slots 7 and 8 two of the 100 MHz PCI X 3 3 V slots e PCI D provides for slots 9 and 10 the two other 100 MHz PCI X 3 3 V slots Video The onboard integrated ATI Rage XL 64 bit VGA chip contains an SVGA controller that is fully compatible with legacy video standards The standard system c
150. m BIOS Press lt Enter gt Use the arrow keys to select the correct bio file Press lt Enter gt When asked toconfirm that you want to flash the new BIOS into memory select Continue with Programming Press lt Enter gt When the utility displays the message that the upgrade is complete remove the diskette Press lt Enter gt As the computer boots after the upgrade check the BIOS identifier version number to make sure the upgrade was successful To enter the Setup program press lt F2 gt when you see the message Press lt F2 gt Key if you want to run SETUP For proper operation load the Setup program defaults To load the defaults press lt F9 gt To accept the defaults press lt Enter gt Set the options in the Setup program to the settings you wrote down before the BIOS upgrade To save the settings press lt F10 gt To accept the settings press lt Enter gt Turn off the computer and reboot Configuration Software and Utilities Recovering BIOS It is unlikely that anything will interrupt the BIOS upgrade however if an interruption occurs BIOS could be damaged In that case you must recover BIOS gt NOTE Because of the small amount of code available in the nonerasable boot block area there is no video support You will not see anything on the screen during the procedure Monitor the procedure by listening to the speaker and looking at the diskette drive LED The procedure for recovering BIOS
151. ment software The BMC e Provides temperature and voltage monitoring e Monitors processor presence and performs Fault Resilient Booting FRB control e Manages SEL interface e Manages SDRR interface e Manages SDR SEL timestamp clock e Provides Field Replaceable Unit FRU information interface e Provides system management watchdog timer functions e Provides pre timeout of watchdog timer SMI capability e Provides front panel NMI handling e Provides event receiver functionality e Manages ISA host and Intelligent Platform Management Bus IPMB interface e Manages secure mode control front panel lock unlock initiation and video blank and diskette write protect monitoring and control e Provides sensor event initialization agent e ACPI Support SRPL8 Server System Product Guide 29 Front Panel Controller FPC The FPC manages e Server power control consolidation from several sources push button power signal from the front panel connector real time clock RTC Intel remote management card IRMC if installed commands from the Intelligent Platform Management Bus e Power and reset switch interfaces e Fault LEDs e Chassis midplane and power supplies Field Replacement Unit FRU inventory interface e Server hard reset generation e Server power fault indication e Interchassis Management Bus ICMB bridge device e EMP connection e LCD interface e Fan predictive failure detection and indicator control e Power
152. menu Advanced Menu e PCI Configuration submenu PCI Mode submenu e I O Device Configuration submenu e Advanced Chipset Control submenu Security Menu Server Menu e System Management submenu e Console Redirection submenu Boot Menu e Boot Device Priority submenu e Hard Drive submenu Exit Menu What it means On screen an option is shown but you cannot select it or move to that field You cannot change or configure the option in that menu screen Either the option is autoconfigured or autodetected or you must use a different Setup screen or you must use the SSU On screen the phrase Press Enter appears next to the option 36 Press lt Enter gt to display a submenu that is either a separate full screen menu or a pop up menu with one or more choices Configuration Software and Utilities The rest of this section lists the features that display onscreen after you press lt F2 gt to enter Setup Not all of the option choices are described because 1 a few are not user selectable but are displayed for your information and 2 many of the choices are relatively self explanatory Press To F1 Get help about an item ESC Go back to a previous item T Select the previous value in a menu option list y Select the next value in a menu option list Select a major menu Change the value of the current menu item to the previous value Change the val
153. ms beschriften und ziehen Sie alle AnschluBkabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD Uber blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Nachdem Sie die oben erw hnten ersten sechs SICHERHEITSSCHRITTE durchgef hrt haben k nnen Sie die Abdeckung abnehmen indem Sie 1 ffnen und entfernen Sie die Verschlu einrichtung Padlock auf der R ckseite des Systems falls eine Verschlu einrichtung installiert ist 2 Entfernen Sie alle Schrauben der Geh useabdeckung 3 Nehmen Sie die Abdeckung ab Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert werden Ein Betrieb des Systems ohne angebrachte Abdeckung kann Ihrem System oder Teile darin besch digen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten auf ordnungsgem en Sitz und Installation 3 Bringen Sie die Abdeckungen wieder am Geh use an indem Sie die zuvor gel sten Schrauben wieder anbringen Ziehen Sie diese gut an 4 Bringen Sie die Verschlu einrichtung Padlock wieder an und schlie en Sie diese um ein unerlaubtes Offnen des Systems zu verhindern
154. nabled Requires SERR to be enabled as well Assert NMI on SERR Disabled Enables SERR to be reported as a critical event via NMI Enabled Enable Host Bus Error Disabled Enables ECC checking on the processor buses Enabled FPC Error Check Disabled Enables Front Panel Controller FPC checking If Enabled enabled BIOS verifies that it can communicate with the FPC HSC Error Check Disabled Enables Hot swap Controller HSC checking If Enabled enabled BIOS verifies that it can communicate with the HSC Server Management Information a Selects Server Management Information submenu SRPL8 Server System Product Guide 47 Server Management Information Submenu Console Redirection Submenu Feature Option 48 Feature Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Option Chassis Serial Number BMC Revision FPC Revision HSC Revision Description Displays Board Part Number Displays Board Serial Number Displays System Part Number Displays System Serial Number Displays Chassis Part Number Displays Chassis Serial Number Displays Baseboard Management Controller Revision Displays Front Panel Controller Revision Displays Hot swap Controller Revision Description CTS RTS CD COM Port Address Disabled When enabled use the I O port specified 3F8 2F8 3E8 IRQ 3 When enabled use the IRQ specified 4 COM Port Baud 9600 K W
155. ndow Table 7 SEL Viewer Menus Menu Options File Open SEL Views data from previously saved SEL file Save SEL Saves the currently loaded SEL data to a file Clear SEL Clears the SEL data from the BMC Exit Quits the SEL Viewer View SEL Info Displays information about the SEL display only All Events Displays the current SEL data from the BMC By Sensor Displays a pop up menu allowing you to view the data from a certain sensor type By Event Displays a pop up menu allowing you to view the data from a certain event type Monitor Real time Displays SEL information in real time allowing you to continuously monitor the SEL events are displayed as soon as they are posted to the SEL Settings Display Hex Verbose Toggles between hex interpreted mode of displaying the SEL records in binary format or verbose format Help About Displays the SEL Viewer version information SRPL8 Server System Product Guide Output Text Binary Determines whether SEL data will be saved to the file and under File Save 59 Sensor Data Record SDR Manager Add In The SDR Manager can display SDR records in either raw form hexadecimal or in an interpreted easy to understand textual form verbose In this window you can e Examine all SDR records through the baseboard management controller BMC in either hex or verbose mode e Examine SDR records by Record type in either hex or verbose mode e Examine SDR records from a p
156. nnection The following server control operations are available with the console manager e Connecting to remote servers e Powering the server on or off e Resetting the server e Switching the server console between EMP active and BIOS redirect modes The console manager uses three management plug ins to monitor the server the SEL SDR and FRU viewers The console manager also has a support plug in phonebook which you can use to create and maintain a list of servers and their phone numbers You can launch the Connect dialog directly from the Phonebook dialog to connect to a selected server How the DPC Console Works The EMP shares the COM2 port with the system When the EMP has control of the port the port operates in command state When the system has control of it the port operates in redirect state When connecting to a server the DPC console checks to determine the current COM2 port state e Command state the default COM2 state In this state the DPC console communicates with the server s firmware allowing the client to remotely reset or power the server up or down The client can also view the server s SEL FRU information or SDR table e Redirect state the DPC console serves as a PC ANSI terminal window for BIOS console redirection Commands typed in this window are transmitted through BIOS to the server s console and text displayed on the server console is displayed on the DPC console s terminal window With the
157. nsulating material on the front panel board Proper insertion of the LED light pipes depends on the correct alignment of the insulating material 3 Insert the screws that you removed earlier and tighten the screws firmly 8 0 inch pounds 4 Reinstall each fan assembly The fan assemblies are keyed and can be installed in only one way 5 Reinstall the top cover the fan array assembly cover and the memory module cover SRPL8 Server System Product Guide 101 OM10692 Figure 26 Removing the Fan Housing A Screws three B Fan housing LCD Module The LCD module displays server information Removing the LCD Module See Figure 27 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the memory module cover see Removing the Memory Module Cover on page 100 3 Remove the fan array housing see Removing the Fan Array Housing on page 101 4 Disconnect the LCD module data and power cables from the front panel board gt NOTE The data cable connector on the front panel board has a lever on each side To free the cable from the connector spread the levers apart pull their ends away from each other The cable disconnects enough that you can remove it fully with your fingers 5 Remove the screw securing the LCD module to the chassis and slide the tab on the left side of 102 the LCD module out of the slot Set the module aside Working Inside the System
158. o hot swap a failed power supply e Green PWR Power LED when blinking AC is applied to the power supply and standby voltages are available When on continuously all power outputs are ready e Yellow FAIL Power Supply Failure LED when on continuously the power supply has failed and it must be replaced e Yellow PR_FL Predictive Failure LED when blinking the power supply is about to fail in the near future because the fan is performing poorly Power Supply LEDs FAIL power supply failure PR_FL predictive failure Power Supply Status Green Yellow Yellow No AC power Off Off Off AC in standby outputs on Blinking Off Off DC outputs on and okay On Off Off Power supply failure Off On Off Current limit On Blinking None Latch Off Predictive failure On Off Blinking Latched Hot Swapping a Power Supply In a fully configured server the power system contains three 750 watt autoranging power supplies the third one is redundant If a single power supply fails in the redundant power system the yellow power supply failure LED on the front panel turns on You can easily hot swap the defective power supply without turning the server power off Power supplies are hot swappable only in configurations with three power supplies A WARNING Because of chassis airflow disruption the power supply bay should not be vacant for more than five minutes when server power is on Exceeding the five min
159. oard from its protective wrapper 2 Position and align the board over the two alignment pins 3 Attach the eight screws removed earlier 4 Connect the diskette and CD ROM power and data cables to their connectors on the backplane 5 Install the peripheral bay in the chassis see Installing the Peripheral Bay on page 118 6 Install SCSI drives see Hot Swapping a SCSI Hard Drive on page 84 OM07503 Figure 37 Peripheral Bay Backplane Hot swap hard disk drive connector Hot swap hard disk drive connector Power connector Diskette drive data connector CD ROM drive data connector Dual CD ROM diskette drive power connector Blind mate board connector SCSI cable connector Tonmoouw gt 120 Working Inside the System Peripheral Bay Blind Mate Board Removing the Peripheral Bay Blind Mate Board See Figure 38 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the profusion carrier tray see Removing the Profusion Carrier Tray on page 104 3 Remove the peripheral bay see Removing the Peripheral Bay on page 117 4 Label and disconnect all cables connected to the blind mate board see Figure 39 on page 123 5 Remove and save the two screws that attach the board to its support in the chassis then remove the board 6 Place t
160. ocessor 3 failed initialization 8267 Board 1 Processor 4 failed initialization 8270 Memory Module 1 failed 8270 Memory Module 2 failed 8280 Coherency Filter failed left data test 8281 Coherency Filter failed right data test 8290 Coherency Filter failed left address test 8291 Coherency Filter failed right address test SRPL8 Server System Product Guide 169 170 Solving Problems Technical Reference This section includes e Connector pinouts and boardset locations e Information on jumpers e System I O addresses e System memory map addresses e Interrupts e Video modes 171 Connectors A B 5 5 G C D E F LE OM10941 Figure 55 Profusion Carrier Layout Front panel connector Connector for processor mezzanine board primary Board configuration jumper block Tag DIMM sockets System JTAG connector Connector for processor mezzanine board secondary Grand connector connects to midplane onmoomw 172 Technical Reference
161. ofusion carrier supports up to two processor mezzanine boards Each mezzanine board supports up to four Pentum III Xeon processors Installed Up to eight Pentium III Xeon processors packaged in single edge contact S E C cartridges and installed in 330 pin Slot 2 processor connectors operating at 5 12 V The profusion carrier provides connectors for two processor mezzanine boards Each mezzanine board provides four Slot 2 connectors The carrier s voltage regulator is automatically programmed by the processor s VID pins to provide the required voltage 22 continued Boardset Description Table 4 Boardset Features continued Feature Memory modules Description Two dual plug in modules containing interleaved pathway to main memory supporting PC100 registererd SDRAM Each memory module supports from 128 MB to 16 GB of error correction code ECC memory using sixteen 72 bit dual inline memory modules DIMMs The modules interface to the profusion carrier through the midplane FSB terminator module This module plugs into any unpopulated Slot 2 connector on either processor mezzanine board The module terminates the FSB GTL signals of the Slot 2 connector when a processor S E C cartridge is not installed in a connector Cache coherency filters The cache coherency filters contain information on each of the two processor buses thus enabling each bus to perform with minimal snoop cycles Th
162. oherency filters before installing the profusion carrier tray See Figure 43 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Remove the Mezzanine Extraction Tool Cache Coherency Hold Down from the front of the processor retention bracket by pulling out the plastic retaining pin 3 With the keyed or notched edge of the filter oriented toward the back of the system insert the filter into the connector 4 Press down firmly on the filter until the front lock retaining latch moves to the locked position 5 Push up on the retaining latch to ensure the filter is properly locked into position 6 Replace the hold down bracket by aligning the tab and the plastic retaining pin on the front of the processor retention bracket Once aligned push in on the pin locking the bracket in place SRPL8 Server System Product Guide 133 Processor Retention Bracket Removing and Installing Removing the Processor Retention Bracket 134 See Figure 44 1 2 3 4 9 Observe the safety and ESD precautions at the beginning of this chapter Remove the memory module page 142 Remove the profusion carrier tray page 104 Remove the cache coherency filters page 132 Find the four metal latch verification brackets located on each side of the profusion carrier tray two on each side To release the latches pull up and out on each tab and expose the four plastic mezzanine lock bars two on each side Release th
163. olidement les panneaux du bo tier avec les vis retir es plus t t 4 Remettez le cadenas en place et verrouillez le afin de pr venir tout acc s non autoris l int rieur du systeme 5 Rebranchez tous les cordons d alimentation c a et c bles externes au syst me 212 suite Warnings AVERTISSEMENT Fran ais suite Le microprocesseur et le dissipateur de chaleur peuvent tre chauds si le syst me a t sous tension Faites galement attention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Danger d explosion si la batterie n est pas remont e correctement Remplacer uniquement avec une batterie du m me type ou d un type quivalent recommand par le fabricant Disposez des piles us es selon les instructions du fabricant Le syst me a t con u pour fonctionner dans un cadre de travail normal L emplacement choisi doit tre e Propre et d pourvu de poussi re en suspension sauf la poussi re normale e Bien a r et loin des sources de chaleur y compris du soleil direct e A l abri des chocs et des sources de vibrations e isol de forts champs lectromagn tiques g en r s par des appareils lectriques e Dans les r gions sujettes aux orages magn tiques il est recomand de brancher votre syst me un supresseur de surtension et de d brancher toutes les lignes de t l communications de votre modem durant un
164. on Updates the EEPROM associated with the baseboard management controller BMC that holds the SDR and FRU area Updates the DMI FRU area located in the BIOS nonvolatile storage device Generically handles FRU devices that might not be associated with the BMC Configuration Software and Utilities When to Run the FRUSDR Load Utility You should run the FRUSDR load utility each time you upgrade or replace the hardware in your server excluding add in boards hard drives and RAM Because the utility must be reloaded to properly initialize the sensors after programming turn the server off and remove the AC power cords from the server Wait approximately 30 seconds then reconnect the power cords and turn on the server What You Need to Do You can run the utility directly from the configuration software CD ROM or from diskettes you create from the CD ROM If you choose to run the FRUSDR Load Utility from a diskette you must copy the utility from the CD ROM and follow the instructions in the included README TXT file If your diskette drive is disabled or improperly configured you must use BIOS Setup to enable it If necessary you can disable the drive after you have finished using the FRUSDR utility How You Use the FRUSDR Load Utility The utility e Is compatible with ROM DOS Ver 6 22 MS DOS Ver 6 22 and later versions e Accepts CFG SDR and FRU load files the executable file for the utility is frusdr exe e Requires th
165. on in the Preferences section of the SSU Main window OR Use the tab and arrow keys to highlight the desired button and press the spacebar or lt Enter gt OR Access the menu bar with the mouse or hot keys Alt underlined letter gt NOTE If you run the SSU from nonwritable media like a CD ROM these preferences will be lost when you exit the SSU SRPL8 Server System Product Guide 55 Launching a Task It is possible to have many tasks open at the same time although some tasks might require complete control to avoid possible conflicts A task achieves complete control by commanding the center of operation until you close the task window To launch a task e In the SSU Main window double click the task name under Available Tasks to display the main window for that task OR e Highlight the task name and click lt OK gt OR e Use the tab and arrow keys to highlight the desired button and press the spacebar or lt Enter gt Resource Configuration Add In RCA Window The RCA provides three major functions e Creates representations of devices that cannot be discovered by the system e Modifies the contents of the system by adding and removing devices e Modifies the resources used by devices 1 From the SSU main window launch the RCA by selecting the Resources task under the RCA heading in the task box 2 When the RCA window appears it displays messages similar to the following Baseboard System Board
166. on is useful for your service representative For a listing of beep codes and error messages that POST can generate see Chapter 7 Solving Problems beginning on page 155 Using BIOS Setup This section describes BIOS Setup options Use Setup to change the system configuration defaults You can run Setup with or without an OS being present Setup stores most of the configuration values in battery backed CMOS the rest of the values are stored in flash memory The values take effect when you boot the system POST uses these values to configure the hardware if the values and the actual hardware do not agree POST generates an error message You must then run Setup to specify the correct configuration Run Setup you can run Setup to modify any standard PC AT feature such as e Select diskette drive e Select parallel port e Select serial port e Set time date to be stored in RTC e Configure IDE hard drive e Specify boot device sequence e Enable SCSI BIOS Run SSU not Setup You must run the SSU instead of Setup to do the following e Enter or change information about a board e Alter system resources e g interrupts memory addresses I O assignments to user selected choices instead of choices selected by the BIOS resource manager Record Your Setup Settings Worksheets for recording your settings are in Appendix B Equipment Log and Configuration Worksheets starting on page 197 If the default values ever need to be r
167. onfiguration comes with 8 MB of onboard SDRAM memory The video controller supports pixel resolutions of up to 1600 x 1200 at 85 Hz and up to 16 7 M colors The SVGA controller supports analog VGA monitors single and multiple frequency interlaced and noninterlaced with a maximum vertical retrace noninterlaced frequency of up to 100 Hz You cannot add video memory to this system Depending on the environment the controller displays up to 16 7 M colors in some video resolutions It also provides hardware accelerated bit block transfers BITBLT of data SRPL8 Server System Product Guide 27 SCSI Controller A QLogic 12160 Ultra 160 SCSI chip provides two 16 bit high speed SCSI channels This high performance SCSI controller is capable of providing data rates up to 160 MB sec per channel in 16 bit operations to ensure maximum data throughput while minimizing PCI bus overhead Each channel is capable of operations using either 8 or 16 bit SCSI providing 10 MB sec Fast 10 or 20 MB sec Fast 20 throughput or 20 MB sec Ultra 40 MB sec Ultra wide 80 MB sec 40 MHz Ultra 2 or 160 MB sec 40 MHz double clocked Ultra 160 The QLA12160 has its own set of PCI configuration registers and SCSI I O registers As a PCI 2 1 bus master the controller supports burst data transfers on PCI up to the maximum rate of 132 MB sec using on chip buffers In the hot swap SCSI hard drive bay the system supports up to two 1 inch SCSI hard disk drives
168. onnect dialog A listof the five most recent connections Initiates connection to selected server SRPL8 Server System Product Guide 67 e Action Power On Off Powers the server on or off with post power up options Reset Resets the server with post reset options FPC FRU Viewer Opens the FPC FRU viewer Phonebook Opens the phonebook dialog e Help Provides version information and help topics for the DPC console Server Control Operations Three server control operations are available from the menu or toolbar of the main DPC console window Connecting to a remote server powering the server on and off remotely and resetting the server The server console mode can also be switched between EMP active and BIOS redirect modes through post power up and post reset options Connecting to Remote Server Select Re Connect from the Connect Menu and follow the Connect dialog shown in Figure 11 Connect Dialog This allows you to connect to a selected server If the client machine is already connected to a server initiating connection generates a warning message The message states that the existing connection will be terminated if you continue trying to initiate the new connection You are prompted to enter the EMP password whenever a connection is attempted m Line selection Serial line Dial up 8 Bit No parity 1 stop bit Direct connect Serial Line Config Ee Pi Baud Rate p Dial up Can
169. or two Pentium Ill Xeon processor one A450NX processor termination eight at FMB maximum load cache modules three coherency boards two at 4 Tag configuration Memory Memory carrier 128 MB DIMM one one Memory carrier 256 MB DIMM 16 carrier each memory carrier only Front panel Front panel Front panel Midplane Midplane Midplane Peripheral One diskette drive one CD ROM drive One diskette drive one CD ROM drive two bay SCSI backplane hard disk drives SCSI backplane Calculating Power Usage Use the worksheet in Table 38 to calculate the total DC power used by your server configuration The documentation that comes with each add in device should specify its current and voltage requirements To calculate the total combined wattage for your server 1 List the current for each board and device in the appropriate voltage level column in the table 2 Add the currents in each column of the table 3 Multiply the voltage by the total current to get the total wattage for each voltage level 4 Add the total wattage for each voltage level to arrive at a total combined power usage on the power supply 194 Power System Description Calculating Power Usage Table 38 Worksheet for Calculating DC Power Usage Current maximum at voltage levels Device 3 3 V 5 V 12 V 12V PHP I O carrier 5A 4 25 A 2A 1A 64 bit PCI slot 1 P1 64 bit PCI slot 2 P2 64 bit PCI slot 3 P3 64 bit P
170. ore the server boots The SSU always includes a checksum with the configuration data so BIOS can detect any potential data corruption before the actual hardware configuration occurs SRPL8 Server System Product Guide 51 What You Need to Do You can run the SSU directly from the configuration software CD ROM after you have installed a CD ROM drive or from a set of DOS diskettes If you choose to run the SSU from DOS diskettes you must copy the SSU from the CD ROM to the diskettes and follow the instructions in the included README TXT file to prepare the diskettes If your diskette drive is disabled or improperly configured you must use the flash resident Setup utility to enable it so you can use the SSU If necessary you can disable the drive after exiting the SSU Information entered using the SSU overrides any entered using Setup Running the SSU Running the SSU Locally Running the ssu bat file provided on the SSU media starts the SSU If the server boots directly from the SSU media the ssu bat file runs automatically If the server boots from different media the SSU can be started manually or by another application When the utility starts in the local execution mode the default mode the SSU accepts input from the keyboard and or mouse The SSU presents a VGA based GUI on the primary monitor The SSU runs from writable nonwritable removable and nonremovable media If the SSU is run from nonwritable media user preference s
171. ory module and place it component side up on a nonconductive static free surface see Removing a Memory Module on page 142 3 Gently push the plastic ejector levers out and down to eject a DIMM from its socket 4 Hold the DIMM only by its edges being careful not to touch its components or gold edge connectors Carefully lift it away from the socket and store it in an antistatic package 5 Repeat to remove other DIMMs as necessary If you are REPLACING DIMMs proceed to Installing DIMMs on page 145 If you are simply REMOVING DIMMs continue the procedure with the following steps 6 Reinstall the memory module 7 Run the SSU BIOS Setup to configure the system and to properly set up advanced memory attributes as required 144 Upgrading Boardset Components Installing DIMMs A CAUTIONS Use extreme care when installing a DIMM Applying too much pressure can damage the socket DIMMs are keyed and can be inserted in only one way Mixing dissimilar metals might cause memory failures later resulting in data corruption Install DIMMs with gold plated edge connectors only in gold plated sockets amp NOTE DIMM slots on the memory module must be installed only in certain configurations See Memory Overview on page 25 and Figure 49 on page 145 for requirements OM10690 Figure 49
172. ot Priority 2 Boot Priority 3 Boot Priority 4 Diskette Drive lt other gt Removable Devices lt other gt Hard Drive lt other gt ATAPI CD ROM Drive lt other gt Equipment Log and Configuration Worksheets C Regulatory Specifications Regulatory and Environmental Specifications Environmental Specifications 10 C to 35 C 50 F to 95 F See Altitude exception 40 C to 70 C 40 F to 158 F Operating temperature Nonoperating temperature Altitude 0 to 3048 m 0 to 10000 ft Note Maximum ambient temperature is linearly de rated between 1520 m 5000 ft and 3050m 10000 ft by 1 C per 305 m 1000 ft Operating humidity 85 noncondensing at 40 C 104 F lt 33 C 91 4 F wet bulb at 40 C 104 F without peripherals Nonoperating humidity 95 noncondensing at 55 C 131 F Safety UL 1950 CSA 950 IEC 950 TUV EN60 950 NEMKO Emissions Certified to FCC Class A tested to CISPR 22B EN 55022 and registered with VCCI Immunity Verified to comply with EN 50082 2 Electrostatic discharge ESD Tested to ESD levels up to 20 kilovolts kV air discharge without physical damage as per Intel environmental test specification Acoustic Sound pressure lt 57 dbA at ambient temperatures lt 28 C measured at bystander positions in operating mode Sound power lt 6 5 BA at ambient temperatures lt 28 C in operating mode Declaration of the Man
173. ower and reset button while the server is in secure mode System Event Log SEL Viewer Add In Clicking on the SEL add in task brings up the SEL viewer add in which allows you to 58 Examine SEL records via the baseboard management controller BMC in hex or verbose mode Examine SEL records by sensor or event type in hex or verbose mode Examine SEL records from a previously stored binary file in hex or verbose mode Save SEL records to a file in either text or binary form Clear SEL entries from the nonvolatile storage area The SEL viewer main window provides access to features of the add in Each option included on the main menu supports an accelerator key Accelerator keys are indicated by an underlined letter in the text listing the option The main window includes support to display the following information for each SEL entry Record identifier Event type Time stamp information Generator identifier Emv revision Sensor type Sensor number Event description Configuration Software and Utilities Figure 6 shows the SEL viewer main window Table 7 lists the window s menus and options I susten setup utitity Do SEL Manager HE ae Pre Init Pre Init Timestamp Lower Critical going low Trigger Lower Critical going low Trigger Reading 0x0000 Tri 0x0000 Tri Pre Init Timestamp Louer critical going low Trigger Reading 0x0000 tri EN A i System Setup Utility Figure 6 SEL Viewer Add in Main Wi
174. packaged in plastic housing Removing a Termination Board 150 See Figure 53 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the top cover see Removing the Top Cover on page 98 3 Remove the processor holddown bracket and set it aside 4 Simultaneously rotate the eject insert levers of the terminator module outward to eject the module out of the Slot 2 connector 5 Slide the module out of the processor retention bracket slot guides and place it component side down on a nonconductive static free surface Upgrading Boardset Components Installing a Termination Board See Figure 53 1 2 mn Grasp the terminator board by the eject insert levers A and carefully slide it into the slot guides of the processor retention bracket until the board stops To seat the board in the mezzanine board connector push down on the levers simultaneously making sure that the lever locks B engage with the slots of the processor retention bracket flange C Insert the hook end of the holddown bracket in the flange of the processor retention bracket Insert the screws you removed earlier and tighten them firmly 8 0 inch pounds Install the top cover OM10694 Figure 53 Installing a Termination Board Assembly A Eject insert levers B Lever locks C Slot in processor retention bracket flange SRPL8 Server System Product Guide 151 Replacing the Backup Batt
175. parts Installing or removing jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Newer jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers If your jumpers do not have such a tab take care when using needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper Take care to gently grip but not squeeze with the pliers or other tool you use to remove a jumper you might bend or break the stake pins on the board SRPL8 Server System Product Guide Cache Coherency Filters Removing and Installing Removing the Cache Coherency Filters See Figure 43 1 Observe the safety and ESD precautions at the beginning of this chapter 2 Remove the Mezzanine Extraction Tool Cache Hold Down bracket from the front of the processor retention bracket by pulling out the plastic retaining pin 3 Press down on the retaining latch and pull the filter up and out of the connector OM10691 Figure 43 Removing the Cache Coherency Filters A Retaining latch B Keyed notched edge 132 Upgrading Boardset Components Installing the Cache Coherency Filters A NOTE If the profusion carrier tray is removed we recommend that you install the cache c
176. programming the BMC FRU area the utility programs chassis board and product FRU information to the DMI fields if the DMI flag follows each FRUAREA command in the configuration file Cleaning Up and Exiting If an update was successfully performed the utility displays a single message and then exits If the utility fails it immediately exits with an error message and exit code 76 Configuration Software and Utilities Upgrading BIOS Preparing for the Upgrade Before you upgrade BIOS record the current BIOS settings obtain the upgrade utility and make a copy of the current BIOS Recording the Current BIOS Settings 1 Boot the computer and press lt F2 gt when you see the message Press lt F2 gt Key if you want to run SETUP 2 Write down the current settings in the BIOS Setup program amp NOTE Do not skip step 2 You will need these settings to configure your computer at the end of the procedure Obtaining the Upgrade Utility You can upgrade to a new version of BIOS using the new BIOS files and the BIOS upgrade utility IFLASH EXE You can obtain the BIOS upgrade file and the IFLASH EXE utility through your computer supplier or from the Intel World Wide Web site http www intel com amp NOTE Review the instructions distributed with the upgrade utility before attempting a BIOS upgrade This upgrade utility lets you e Upgrade BIOS in flash memory e Update the language section of BIOS The follow
177. r 7 While facing the front of the server push the top cover toward the back of the chassis to disengage the row of tabs attaching the cover to the chassis 8 Push the cover back about an inch then lift it straight up Set the cover aside 9 Lift the 240 VA protective cover from the chassis see Figure 24 on page 99 OM11017 Figure 23 Removing the Top Cover A Two screws 98 Working Inside the System OM11029 Figure 24 Removing the 240 VA Protective Cover Installing the Top Cover 1 2 3 Observe the safety precautions warnings and cautions at the beginning of this chapter Install the 240 VA protective cover While facing the back of the server position the top cover over the chassis so that the tabs along the edges of the cover align with the slots in the top edge of the chassis Gently lower the cover straight down on top of the server Place your hands on opposite sides of the cover then push the cover forward to seat it Attach the cover to the chassis with the screws you removed earlier and tighten them firmly 6 0 inch pounds Connect all external cables and power cords to the server SRPL8 Server System Product Guide 99 Removing the Memory Module Cover See Figure 25 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Remove the four screws securing the memory module cover and remove the cover OM10703 Figure 25 Removing t
178. r on page 98 4 Disconnect the ICMB signal cable from the I O riser board A in Figure 32 5 Remove and save the screw B in Figure 32 6 Holding the board by the top edge or upper corners pull it straight upward away from the PHP I O carrier until the edge connector of the board pulls free from its connector Make sure that you do not scrape the board against other components 7 Place the board on a nonconductive static free surface or store it in an antistatic protective wrapper SRPL8 Server System Product Guide 111 Installing the I O Riser Board See Figure 32 1 Remove the I O riser board from its antistatic protective wrapper 2 Holding the board by the top edge or upper corners carefully insert the edge connector of the board into the connector on the PHP I O carrier Press the board firmly into the connector until it is fully seated 3 Insert the screw you removed earlier in the threaded hole in the chassis B in Figure 32 Tighten the screw firmly 8 0 inch pounds 4 Connect the ICMB signal cable to the riser board A in Figure 32 5 Reinstall the top and 240 VA protective covers see Installing the Top Cover on page 99 OM07323 Figure 32 I O Riser Board A O connector B Screw 112 Working Inside the System PHP LED Board Removing a PHP LED Board See Figure 33 1 2 3 4 Observe the safety precautions warnings and cautions at the beginning of th
179. r Pinout Pin Signal Pin Signal 1 STROBE_L 10 ACK_L 2 Data bit 0 11 Busy 3 Data bit 1 12 PE 4 Data bit 2 13 SLCT 5 Data bit 3 14 AUFDXT_L 6 Data bit 4 15 ERROR_L 7 Data bit 5 16 INIT_L 8 Data bit 6 17 SLCTIN_L 9 Data bit 7 18 25 GND Serial Ports A and B 1 5 00000 0000 6 Table 23 Serial Port Connector Pinout 9 OM11311 Pin 0 CO N o a A OJ N Signal DCD RXD TXD DTR GND DSR RTS CTS RIA Description Data carrier detected Receive data Transmit data Data terminal ready Ground Data set ready Request to send Clear to send Ring indication active SRPL8 Server System Product Guide 177 Universal Serial Bus USB The SRPL server provides two external USB connectors at the back panel Table 24 lists the pinout for each connector Boor OM08036 Table 24 USB Connector Pinout Pin Signal Notes Avo vee Over current monitor line port 0 A2 Datalo Differential data line paired with DATAHO A3 DataHO Differential data line paired with DATALO aM GND Cable ground Bt vec Over current monitor line port 1 B2 DATALI Differential data line paired with DATAH1 B3 DATAH1 Differential data line paired with DATAI1 B4 GND Cable ground OM08027 Table 25 Wide SCSI Connector Pinout Pin Signal Pin Signal 1 16 49 50 GND GND 17 TERMPWR 51 TERMPWR 18 TERMPWR 52 TERMPWR 19 Reserved 53 Reserved
180. r page numbers in this chapter Table 14 Procedures in Chapter 5 Item Page Item Page e Front bezels 95 e I O tray 113 e Server covers 95 e ICMB board 116 e Fan array housing 101 e AC filter and cable 117 e LCD module 102 e Peripheral bay 117 e Profusion carrier tray 104 e Peripheral bay backplane 119 e Front panel controller board 106 e Peripheral bay blind mate board 121 e Add in boards 108 e Diskette drive 124 e I O riser board 111 e Peripheral drives 126 PHP LED Board 113 Tools and Supplies Needed Phillips cross head screwdriver 1 and 2 bit Small flat bladed screwdriver Jumper removal tool or needle nosed pliers Antistatic wrist strap and conductive foam pad recommended Pen or pencil Equipment log as you integrate new parts into the system add information about them to your equipment log page 197 Record the model and serial number of the system all installed options and any other pertinent information specific to the system You will need this information when running the SSU Safety Before You Remove Server Covers Before removing covers at any time to work inside the system observe these safety guidelines 1 2 3 4 Turn off all peripheral devices connected to the system Turn off the system by using the push button on off power switch on the front of the system Unplug the AC power cords from the system or wall outlet
181. r software on the local system In this model of remote operation the SSU executes in text mode exclusively on the remote server Any files required for the SSU to execute must be on the remote server on removable or nonremovable media Direct Platform Control DPC Console Using the DPC console in conjunction with BIOS console redirection you can e See the BIOS Setup Screen F2 e Control the keyboard from a local system connected to a remote server by a modem or direct serial connection The local system must be running the DPC console software This method of redirection provides text mode video and keyboard redirection support only It does not support redirection of the mouse For specific instructions on implementing the DPC console see Direct Platform Control DPC Console on page 63 SRPL8 Server System Product Guide 53 Starting the SSU The SSU is a collection of task oriented modules plugged into a common framework called the Application Framework AF The AF provides a launching point for individual tasks and a location for setting customization information 1 Turn on your video monitor and your system 2 Start the SSU through one of two ways e After creating a set of SSU diskettes from the CD ROM Insert the first SSU diskette in drive A Press the reset button or lt Ctrl Alt Del gt to reboot your server from the diskette e Directly from the Server Configuration Software CD ROM Insert the configuration sof
182. r tray see Profusion Carrier Tray on page 104 Remove the I O tray see I O Tray on page 114 Remove the three screws that attach the upper midplane support bracket to the chassis A CAUTION ER As you remove the upper bracket make sure the edge of the bracket does not gouge or slice the ribbon cables that are routed between the bracket and the chassis wall Remove the upper bracket by pulling it straight up out of the chassis Remove the four screws that attach the lower bracket midplane assembly to the chassis Remove the bracket midplane assembly by pulling it straight up out of the chassis To remove the midplane from its support bracket remove and save the seven screws that attach the two parts Place the midplane on a nonconductive static free surface or store it in an antistatic protective wrapper Installing the Midplane See Figure 47 1 Remove the midplane from its protective wrapper 2 Position the midplane on its support bracket and insert the screws loosely into the threaded standoffs 3 Make sure the midplane is properly positioned then tighten all screws firmly 8 0 inch pounds 4 Install the midplane support bracket assembly in the chassis then secure it with the four 140 screws you removed earlier Upgrading Boardset Components gt NOTE The UPPER midplane support bracket has a number of slots that mate with rectangular tabs on the top of the midplane 5 Install the
183. rational e Provides a system level view of the server I O devices e Supports saving and restoring system configuration When to Run the SSU The SSU is a DOS based utility that supports extended system configuration operations for onboard resources and add in boards You can also view the SEL and set system boot and security options Use the SSU when you need to e Add and remove boards affecting the assignment of resources ports memory IRQs DMA e Modify the server s boot device order or security settings e Change the server configuration settings e Save the server configuration e View or clear the SEL e View FRU information e View the SDR table The SSU is PCI aware and works with any compliant configuration CFG files supplied by the peripheral device manufacturer The I O carrier comes with a CFG file describing the characteristics of the carrier and the system resources it requires To specify a system configuration SSU uses the information provided by e CFG files e Configuration registers e Flash memory e The information that you enter The SSU then writes the configuration information to flash memory The SSU stores configuration values in flash memory These values take effect when you boot the server POST checks the values against the actual hardware configuration if the values do not agree POST generates an error message You must then run the SSU to specify the correct configuration bef
184. rd BIOS requires you to enter the user password before you can boot the server or run the SSU If you set both passwords entering either password lets you boot the server or enable the keyboard and mouse Only the administrative password lets you change the server configuration with the flash resident Setup utility Secure Boot Mode Secure boot mode allows the server to boot and run the OS However you cannot use the keyboard or the mouse until you enter the user password You can use Setup to put the server in secure boot mode If BIOS detects a disk in the CD ROM drive or a diskette in floppy drive A at boot time it prompts you for a password When you enter the password the server boots from the disk in the CD ROM drive or the diskette in drive A Entering a password also disables secure mode If there is no disk in the CD ROM drive or diskette in drive A the server boots from drive C and automatically goes into secure mode All enabled secure mode features go into effect at boot time If you set a hot key combination you can secure the server immediately Boot Sequence Control The BIOS security features determine the boot devices and the boot sequence They also control disabling writes to the diskette drive in secure mode You can use the SSU or Setup to select each boot device The default boot sequence is diskette hard disk CD ROM and network SRPL8 Server System Product Guide 31 Boot Without Keyboard The server can boo
185. reviously stored binary file in either hex or verbose mode e Save the SDR records to a file in either text or binary form The SDR Manager main window provides access to features of the add in through menus Each option included on the main menu supports an accelerator key Accelerator keys are indicated by an underlined letter in the text listing the option Figure 7 shows the SDR Manager main window Table 8 lists the window s menus and options SDR Manager File View Settings Help Record ID 0020h SDR Version 10h Record Type 01h Record Length 2Fh Sensor Owner ID 20h Sensor Owner LUN 00h Sensor Number 04h Sensor Owner Confirmation 0002h Sensor Module FRU Inv Device Owner ID 10h Sensor Initialization Fih Sensor Capabilities F h Sensor Type 02h Event Reading Base Type 01h Event Trigger Mask 6A69h Event Reading Mask 1200h Sensor Units 1 00h Sensor Units 2 Base Unit 04h Sensor Units 3 Modifier Unit 00h System Setup Utility Figure 7 SDR Manager Main Window 60 Configuration Software and Utilities Table 8 SDR Manager Menus Menu Options File Open FRU Opens FRU data from a previously saved file Save SDR Saves SDR data to a file in binary raw or verbose text format Exit Quits the SDR Manager View SDR Info Displays SDR information as returned by the GetSDRinfo interface of the BMC All Records Displays all records in the SDR repository By Record Displays
186. roller accordingly The keyboard controller is functionally compatible with the 8042A microcontroller The system can be locked automatically if no keyboard or mouse activity occurs for a predefined length of time if specified through the SSU see security options in Security Add In on page 57 Once the inactivity lockout timer has expired the keyboard and mouse do not respond until the previously stored password is entered Boardset Description Server Management Most of the server management features are implemented using three microcontrollers the baseboard management controller BMC on the I O carrier the front panel controller FPC on the front panel board and the hot swap controller HSC on the LVDS backplane The primary function of the BMC is to autonomously monitor system platform management events and log their occurrence in the nonvolatile System Event Log SEL While monitoring the BMC maintains the nonvolatile sensor data record repository SDRR from which run time information can be retrieved The BMC provides an ISA host interface to SDRR information so software running on the server can poll and retrieve the current status of the platform A shared register interface is defined for this purpose SEL contents can be retrieved after system failure or during regularly scheduled maintenance To retrieve SEL contents field service personnel use tools such as the SSU SEL Viewer or the Intel Server Control manage
187. roller board do the following Verify that the video controller board is fully seated in the I O carrier connector and verify that the video monitor is plugged in to the ACTIVE video controller Reboot the system for changes to take effect If there are still no characters on the screen after rebooting the system and POST emits a beep code write down the beep code you hear This information is useful for your service representative See POST Codes and Countdown Codes on page 163 If you do not receive a beep code and characters do not appear the video display monitor or video controller may have failed You can verify this by trying the monitor on another system or trying a different monitor on this system Contact your service representative or authorized dealer for assistance SRPL8 Server System Product Guide 159 Characters Are Distorted or Incorrect Check the following Are the brightness and contrast controls properly adjusted on the video monitor See the manufacturer s documentation Are the video monitor signal and power cables properly installed Is the correct monitor video board installed for your operating system If the problem persists the video monitor may be faulty or it may be the incorrect type Contact your service representative or authorized dealer for assistance System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly system components could be damaged Ch
188. rrier Tray a cheat dalia cee te ahs ees it nee 104 Removing the Profusion Carrier Tray 104 Installing the Profusion Carrier Tray nennen 104 Front Panel Controller Boards ce ec haat lava ecg nee i i i cee tenes 106 Removing the Front Panel Controller Board ii 106 Installing the Front Panel Controller Board ne nnnnnnnnennnennnnnnnnnnne nn 106 AAA as 108 Installing Replacing an Add In Board 108 Removing an Add In Board estarlo didas 111 KO Riser Board isos Mana tete ai aaa 111 Removing the I O Riser Board eu seen Heel 111 Installing the I O Riser Board 112 SRPL8 Server System Product Guide v PHP EEDIB Ard anna een 113 Removing a PHP LED Board eee asi 113 Installing a PHP LED Board 114 VO Tate er ea ae Rue pirati 114 Removing the l O Traveler et 114 Installing the VO Tray u ie 115 Interchassis Management Bus ICMB Board 116 Removing the ICMB Board 116 Installing the IGMB Board run desire 116 AG Filler and Cable irc ella ail 117 Removing the AC Filter and Cable 117 Installing the AC Filter and Cab Oscars tics ennemie o 117 E 117 Removing the Peripheral Bay ss 117 Installing the Peripheral Bay ent es anes ben ee ses etat pates 118 Peripheral Bay Backplane osas nn fatale 119 Removing the Peripheral Bay Backplane cnn 119 Installing the Peripheral Bay Bac
189. rs LEDs Basic Input Output System BIOS Power on Self Test POST and Setup Utility stored in a flash memory device System Setup Utility SSU QLogict SCSI Utility Emergency Management Port EMP utility Field Replacement Unit FRU and Sensor Data Record SDR load utility Chassis Description Chassis Front Controls and Indicators ABC DEFG H Figure 2 Front Controls and Indicators SRPL8 Server System Product Guide OM07301 16 Table 3 Front Controls and Indicators Item Feature Description Front Panel A Power switch When pressed it turns on or off the server The 5 V standby voltage is ON whenever the server is plugged in B Reset switch When pressed it resets the server and causes the power on self test POST to run C NMI switch When pressed it causes a nonmaskable interrupt This switch is recessed behind the front panel to prevent inadvertent activation It must be pressed with a narrow tool not supplied D Power LED green When lit continuously it indicates the presence of DC power in the server When not lit it indicates power is turned off or power source is disrupted E Power fault LED yellow When lit continuously it indicates presence of DC power F Cooling fault LED yellow When fl
190. s are toward your right 4 Orient the drive so that e The drive s label faces away from the carrier heatsink toward the carrier fingers e The drive s connector faces away from the carrier handle A CAUTION Be careful not to bend or damage the carrier s metal fingers as you attach the drive to the carrier 5 Position the drive in the end of the carrier away from the handle then slide the drive toward the handle 84 Hot Swapping Fans SCSI Hard Drives and Power Supplies 6 Place the drive and carrier assembly on an antistatic surface of a table or a workbench so that the drive handle and fingers overlap the edge of the table or the workbench see Figure 17 7 Using four screws of the appropriate size and length not supplied attach the carrier to the drive A CAUTION vom Some specific hard disk drive designs require electrical isolation of the drive from the chassis or other ground paths These drives are usually clearly labeled with this requirement on the drive Full height 1 6 inch drives with this requirement must have an electrical isolator like durable mylar tape placed between the EMVESD grounding fingers and the top cover of the drive Failure to isolate this type of drive from the ground path will result in unpredictable operation of the drive including severely impacted performance and data corruption OM07153 OM08268 Figure 16 Hard Disk Drive and Carrier Figure 17 Mounting Hard Disk
191. s bootable and that all BIOS files to include the recovery file are on the diskette The BIOS recovery file will have a rec file extension for example bios rec Insert the BIOS recovery diskette in drive A and then power on the system After the system boots the speaker emits a single beep and the recovery process begins This takes about three minutes When the recovery process completes the speaker emits two beeps While in the recovery mode there is no screen display on the monitor The keyboard is disabled as the system automatically recovers BIOS The following beep codes describe the recovery status Beep Code Message 2 Successful completion no errors 4 The system could not boot from the diskette The diskette may not be bootable Continuous series of The wrong BIOS recovery files are being used and or the recovery switch is in the low beeps wrong position 3 Power off the system 4 Return switch position 2 to the left most default position 5 Reinstall the PCI hot plug cover using the original screws remove the diskette from drive A Power on the system and resume normal operation Technical Reference System I O Addresses Table 30 shows the location in I O space of all directly I O accessible registers Table 30 System I O Addresses VO Address Resource I O Address Resource 0000 001F DMA controller 0170 0177 Secondary IDE controller 0020 002
192. sec 13 3 sec 10 sec 6 sec 2 sec Selects key repeat rate Keyboard auto repeat delay 1 4 sec 1 2 sec 3 4 sec 1 sec Selects delay before key repeat 40 Configuration Software and Utilities Advanced Menu Default values are in bold typeface A WARNING Setting items on this menu to incorrect values may cause your system to malfunction Feature Option Description Processor Serial Number Disabled Enables or disables the Processor Serial Number feature Enabled of the Pentium III Xeon processor Reset Configuration Data No If Yes is selected BIOS clears the System Yes Configuration Data during the next boot The field is automatically reset to No in next boot Use Multiprocessor 1 1 Selects the version of the Multiprocessor Specification to Specification 1 4 use Some operating systems require version 1 1 for compatibility reasons Large Disk Access Mode CHS Select the drive access method for IDE drives Most LBA operating systems use Logical Block Addressing LBA However some operating systems may use the Cylinder Head Sector CHS See your operating system documentation for more information Pause Before Boot Disabled If enabled BIOS pauses five seconds before booting the Enabled operating system Hot plug PCI Master Control Disabled Set to Enable to create the Hot plug PCI Resource Enabled Table and to reserve resources for each hot plug PCI slot Hot plug PCI Allocation Level Disabled Set
193. seconds This elapsed time allows the drive platter to stop rotating 4 Carefully slide the assembly out of the bay and place it on an antistatic surface 5 Orient the new carrier and drive assembly in front of the hot swapping bay guide rails so that the metal fingers of the perforated metal bracket attached to the carrier are facing up Make sure you correctly place the carrier into the guide rails to avoid damage 6 While grasping only the drive carrier handle firmly push the assembly into the bay until the driver carrier latches A CAUTION Do not press on the perforated metal bracket of the carrier when you push the assembly into the bay Otherwise you may damage the metal fingers of the bracket SRPL8 Server System Product Guide 87 Hot Swapping Power Supplies gt NOTE You must have three power supplies installed to hot swap a supply If you have only two supplies installed they must occupy the left and center bays as you face the back of the server see Figure 19 on page 89 When the yellow power supply failure LED on the front panel turns on you can determine which power supply is defective by checking the three status LEDs on the back of each supply Ifa power supply fails the yellow FAIL LED on the back of the power supply will be on continuously You must hot swap the power supply remove and replace it with a good one If the server contains three power supplies you DO NOT need to shut down the server t
194. see the Diagnostic help disks that end with the extension HLP They are ASCII files that you can print to form a manual of all tests in this product e The program called Testview uses a simple DOS based menu system e The program called T EXE is a noninteractive test executable used to run test program modules from DOS batch files e The README TXT file for diagnostics tells how to install the program CAUTION Read help information for a test before running it the diagnostic package contains many optional tests that should be used only by a user with advanced technical knowledge Inadvertent actions could be damaging such as running a hard drive write test on a hard disk All tests that require external hardware user interaction or are destructive are disabled in the default configurations Before using such a test make sure you read and understand the help information for that test SRPL8 Server System Product Guide 157 Monitoring POST See Chapter 3 Configuration Software and Utilities beginning on page 33 Verifying Proper Operation of Key System Lights As POST determines the system configuration it tests for the presence of each mass storage device installed in the system As each device is checked its activity light should turn on briefly Check for the following Does the diskette drive activity light turn on briefly If not see Diskette Drive Activity Light Does Not Light on page 160 If a second d
195. supply predictive failure detection and indicator control e ACPI Support e Wake on LAN via Magic Packet support Hot swap Controller HSC 30 The HSC e Implements the SAF TE command set e Controls the fault lights and drive power on e Provides a path for management information via SCSI e Retrieves drive fault status backplane temperature and fan failure information via the IPMB e Queries the status of the front panel controller for power supply information e Controls drive power on and power down facilitating hot swapping Boardset Description System Security There are several ways to prevent unauthorized entry or use of the server Security with BIOS Setup e Set server administrative and user passwords e Set secure mode to prevent keyboard or mouse input and to prevent use of the front panel controls e For more information see Security Menu on page 45 Security with the System Setup Utility SSU e Enable the keyboard lockout timer so that the server requires a password to reactivate the keyboard and mouse after a specified time out period of 1 to 128 minutes e Set an administrative password e Set a user password e Activate the secure mode hot key e Disable writing to the diskette drive e For more information see Security Add In on page 57 Password Protection BIOS passwords prevent unauthorized tampering with the server If you set the user password but not the administrative passwo
196. t e Away from sources of vibration or physical shock e Isolated from strong electromagnetic fields produced by electrical devices e In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppresser and disconnect telecommunication lines to your modem during an electrical storm e Provided with a properly grounded wall outlet e Provided with sufficient space to access the server power supply cords because it serves as the product s main power disconnect SRPL8 Server System Product Guide 211 AVERTISSEMENT Francais Le bloc d alimentation de ce produit ne contient aucune pi ce pouvant tre r par e par l utilisateur Ce produit peut contenir plus d un bloc d alimentation Veuillez contacter un technicien qualifi en cas de probl me Ne pas utiliser ni modifier le cordon d alimentation secteur fourni s il ne correspond pas exactement au type requis Le bouton poussoir Marche Arr t de l alimentation CC situ sur le syst me ne coupe pas l alimentation en CA du syst me Pour couper toute alimentation en CA au syst me vous devez d brancher le cordon d alimentation secteur de la prise murale ou du bloc d alimentation CONSIGNES DE S CURIT Lorsque vous ouvrez le bo tier pour acc der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s
197. t IDE submenu 204 worksheet keyboard features submenu 204 worksheet main menu 204 worksheet Security menu 205 worksheet server console redirection 206 worksheet server menu 205 worksheet system management submenu 206 soft boot 155 SSU See system setup utility status indicators drive activity LED green 16 drive fault LED yellow 16 drive power LED green 16 SCSI drives 87 supplies 81 switches DC power 130 155 location on I O carrier 182 NMI 16 power 16 power on off 93 94 reset 16 155 server power 89 system power 98 system setup utility SSU CFG files 51 changing configuration 33 customizing 55 diskette drive required to run SSU 33 exiting 63 inactivity lockout timer 28 launching a task 56 location 51 running 54 locally 52 remotely 52 SCI files 51 when to run 51 Index system setup utility SSU continued worksheet add remove board 199 worksheet management subsystem 202 worksheet system sensor control 202 T temperature maximum ambient drives 18 termination board installing 151 removing 150 requirements 147 timer keyboard or mouse inactive 28 lockout inactivity setting in SSU 28 tools 81 tools and equipment 93 U upgrade Flash utility 77 USB ports 23 utilities BIOS update 33 Direct Platform Control DPC Console 33 63 firmware update 33 80 FRUSDR load utility 33 72 QLogic SCSI 80 QLogic SCSI boot time message 34 SCSI 33
198. t of time Removing a Fan See Figure 15 1 Remove the screw A that secures the fan array cover B 2 Slide the fan array cover to the server front to free it from the locking tabs Lift the cover 3 Look at the yellow fan failure LEDs to determine which fan is defective 4 Insert your thumb and forefinger into the grasp holes B in Figure 15 of the failed fan 5 Pull the fan straight up out of the housing Set it aside Replacing a Fan See Figure 15 1 Remove the new fan from its protective packaging 2 Record the model and serial numbers of the fan in your equipment log page 197 gt NOTE Fans are keyed and can be inserted in only one way Be sure that the fan connector mates with the front panel connector when aligning the fan in the fan cavity 82 Hot Swapping Fans SCSI Hard Drives and Power Supplies 3 Align the fan with the fan cavity 4 Push straight down on the fan until it is fully seated in the cavity 5 Replace the fan array cover with its securing screw OM10702 Figure 15 Removing Hot swapping a Fan A Fan cover screw B Fan cover C Grasp holes D Fan SRPL8 Server System Product Guide 83 Hot Swapping a SCSI Hard Drive Hot Swapping Bays Two 3 5 inch hot swapping bays provide space for 3 5 inches X 1 inches or 1 6 inches single connector attachment SCA2 SCSI hard disk drives You can install up to two industry standard wide ultra or wide ultra2 SCA type hard disk drives
199. t the system If a failure occurs POST emits beep codes that indicate errors in hardware software or firmware If POST can display a message on the video display screen it causes the speaker to beep twice as the message appears 162 Solving Problems POST Codes and Countdown Codes BIOS indicates the current testing phase during POST after the video adapter has been successfully initialized by outputting a 2 digit hex code to I O location 80h To view POST codes you must install an optional PCI POST add in board For more information contact your customer service representative Table 16 Port 80 Codes POST Code Beeps Error 02 Verify Real Mode 03 Disable NMI 04 Get Processor type 06 Initialize system hardware 08 Initialize chip set registers with initial POST values 09 Set in POST flag OA Initialize processor registers 0B Enable processor cache OC Initialize caches to initial POST values OE Initialize I O OF Initialize the local bus IDE 10 Initialize Power Management 11 Load alternate registers with initial POST values new 12 Restore processor control word during warm boot 13 Reset PCI bus masters t Initialize keyboard controller 16 1 2 2 3 BIOS ROM checksum 17 Prepare to size RAM 18 8254 timer initialization 1A 8237 DMA controller initialization 1C Reset Programmable Interrupt Controller 20 1 3 1 1 Test DRAM refresh 22 1 3 1 3 Test 8742 Keyboard Controller 24 Set ES segment register to 4 GB 28 1 3 3 1 Autosi
200. t with or without a keyboard Before it boots BIOS displays a message keyboard detection During POST BIOS automatically detects and tests the keyboard if one is present Locked Power and Reset Switches The power and reset push button switches on the front panel are locked when the server is in secure mode To exit from the secure mode you must enter your user password Diskette Write Protect If Diskette Write Protect is enabled in Setup it write protects the diskette drive only while the server is in the secure mode To exit secure mode enter your user password Video Blanking If Video Blanking is enabled in Setup the video display will be off when the server is in secure mode To exit secure mode enter your user password Emergency Management Port EMP The EMP is a feature of server management EMP lets the front panel controller FPC communicate with the server via the serial port even if the server power is off To restrict EMP access you can enable an administrator password in Setup If the administrator enters a new EMP password or clears an old one BIOS sends the appropriate command via the PC bus interface to the FPC To change the password from Setup again enter the new password twice If the administrator sets the Password Clear switch to the Clear position BIOS clears the administrator and user passwords to change switches see Configuration Switches on page 182 It also attempts to clear the EMP password
201. tatic protective wrapper if you placed it in one 2 Position the carrier over the snap on and threaded standoffs on the center bulkhead of the chassis 3 Press the carrier onto the snap on standoffs and insert the screws loosely into the threaded standoffs 4 Make sure the carrier is properly seated and tighten all screws firmly 8 0 inch pounds 5 Install the I O riser board 6 Install the ICMB board 7 Install the I O tray Run the SSU and use the saved configuration file to restore all options to the same settings For information about running this utility see Using the System Setup Utility SSU 138 Upgrading Boardset Components SW4G1 ON TTT Ol SRPL8 Server System Product Guide Figure 46 PHP I O Carrier OM08749 139 Midplane Removing and Installing Removing the Midplane See Figure 47 A CAUTION DEEE Disconnect EVERYTHING from the midplane before trying to remove it Failure to do so can result in serious damage to the midplane and any components still connected to the midplane Observe the safety and ESD precautions at the beginning of this chapter Remove the power supplies see Hot Swapping Power Supplies on page 88 Remove the profusion carrie
202. tches cannot power down Enabled the slots If disabled the power to each slot can be removed by the individual slot switches 2 GB Memory Limit Disabled If enabled BIOS limits the top of memory to 2 GB Additional Enabled memory becomes inaccessible Configuration Software and Utilities Security Menu Default values are in bold typeface Feature Option Description User Password Is Set Status only Administrator password must be enabled Clear before user password can be enabled User password is enabled by entering a user password and disabled by entering a null user password Administrator Password Is Status only Enabled by entering an administrator password and disabled by entering a null administrator password Set User Password Press Enter When the Enter key is pressed the user is prompted for a password press ESC key to abort Set Administrator Password Press Enter When the Enter key is pressed the user is prompted for a password press ESC key to abort Password on Boot Disabled Requires password entry on boot The system remains in Enabled Secure Mode until password is entered Password on Boot takes precedence over Secure Mode Boot Secure Mode Timer Disabled Sets the period of key PS2 mouse inactivity specified 1 min before Secure Mode activates Requires a password for 2 min Secure Mode to function 5 min 10 min 20 min 1 hr 2 hr Secure Mode Hot Key Disabled Assigns a hot key that invo
203. te with this server even while power is down via an Interchassis Management Bus ICMB Push button switches control power up reset and nonmaskable interrupt NMI functions LEDs indicate power on power supply failure hard drive failure or a fan or other server cooling failure An LCD panel provides information about boot status available number of processors and other server management information Midplane The midplane e Electrically connects the PHP I O and profusion carriers e Contains the sockets for the memory modules e Distributes DC power to the PHP I O and profusion carrier disk backplane cooling fans memory boards and front panel board e Distributes the power load of the server among two or three 750 watt autoranging power supplies SRPL8 Server System Product Guide 23 Processor Overview 24 Each Pentium III Xeon processor is packaged in a single edge contact S E C cartridge The cartridge includes e The processor core with an integrated 32 KB primary L1 cache e The secondary L2 cache e A thermal plate e A back cover Processors used with the SRPL8 server must be e 5 12 volts e 100 MHz FSB e 1lor2 MB cache e Validated by Intel for SRPL8 systems Each processor implements the MMX technology with streaming SMID extensions and maintains full backward compatibility with the 8086 80286 Intel386 Intel486 Pentium and Pentium Pro processors The processor s numeric
204. ter Remove the memory module page 142 Remove the cache coherency filters page 132 Remove the profusion carrier tray page 104 Remove the processor retention bracket page 134 Remove the mezzanine board s page 135 Remove the front panel controller board page 106 Remove the screws in the base of the S E C cartridge guides Remove the cartridge guides they come out as one unit and set them aside Remove the screws securing the profusion carrier to the chassis Lift the profusion carrier to unsnap it from the snap on standoffs Place the carrier on a nonconductive static free surface or store it in an antistatic protective wrapper Installing the Profusion Carrier 136 See Figure 45 1 Remove the profusion carrier from its protective wrapper 2 Position the carrier over the snap on and threaded standoffs on the profusion tray 3 Press the carrier onto the snap on standoffs and insert the screws loosely into the threaded standoffs 4 Position the cartridge guides over the profusion carrier and loosely insert the retaining screws into the threaded standoffs 5 Make sure the carrier is properly seated then tighten all screws to 8 0 inch pounds 6 Install the mezzanine board s see page 135 7 Install the front panel board 8 Install the profusion tray Upgrading Boardset Components OM08755 Figure 45 Separating the Pro
205. the following Are all the power supplies plugged in Is the power turned on to the outlet Is there a blown fuse or breaker Is the system connected to a 208 VAC source Is the system operating normally If so the power LED is probably defective or the cable from the front panel to the I O carrier is loose Are there other problems with the system If so check the items listed under System Cooling Fans Do Not Rotate Properly on page 160 If all items are correct and problems persist contact your service representative or authorized dealer for assistance No Beep Codes If the system operates normally but there was no beep the speaker might be defective If the speaker is enabled but the speaker does not function contact your service representative or authorized dealer for assistance Record the beep code emitted by POST and see Error and Informational Messages on page 162 No Characters Appear on Screen Check the following Is the keyboard working Check to see that the Num Lock light is functioning Is the video monitor plugged in and turned on Many modern video monitors shut down when inactive and may require a moment to warm up when activated Are the brightness and contrast controls on the video monitor properly adjusted Are the video monitor switch settings correct Is the video monitor signal cable properly installed Is the onboard video controller enabled If you are using an add in video cont
206. tricted Mode Access Direct Connect Modem Mode EMP Direct Connect Modem Mode Updated from the Front Panel Controller firmware Selected when the EMP is enabled Preboot Only EMP is enabled during power down or POST only Always Active EMP is always enabled Disabled EMP is disabled Enables Restricted Mode In Restricted Mode Power Down Front Panel NMI and Reset Control via EMP are disabled Allows the user to connect to a local machine without using a modem Configuration Software and Utilities System Management Submenu Default values are in bold typeface Feature Option Description Firmware SMIs Disabled Enables SMI generation by agents on the Intelligent Enabled Platform Management Bus IPMB Because BIOS requires SMls for various tasks setting this field to disabled does not disable all sources of SMls System Event Logging Disabled Enabled logs critical system events Enabled Clear Event Log Disabled Clears the System Event Log SEL This option is reset Enabled to Disabled on each boot Memory Scrubbing Disabled Enables memory scrubbing by the Profusion chip set Enabled AERR Enable Disabled Enables AERR to be asserted on the processor host Enabled buses Assert NMI on BERR Disabled Enables BERR to be reported as a critical event via NMI Enabled Requires SERR to be enabled as well Assert NMI on PERR Disabled Enables PERR to be reported as a critical event via NMI E
207. tware CD ROM into your CD ROM drive Press the reset button or lt Ctrl Alt Del gt to reboot When prompted to do so press lt F2 gt to enter BIOS Setup From the Boot Menu select the Boot Device Priority option Select CD ROM as your primary boot device Save those settings and exit BIOS Setup The server will boot from the CD ROM and display a menu of options Follow the instructions in the menu to start the SSU 3 When the SSU title appears on the screen press lt Enter gt to continue 4 The mouse driver loads if it is available press lt Enter gt to continue This message appears Please wait while the Application Framework loads When the main window of the SSU appears you can customize the GUI before continuing See Customizing the SSU on page 55 system Setup Utility BE File Preferences Help Topics Tasks Available Tasks Task Description The RCA provides support to configure system MBA resources such as memory I O ports and DMA channels It also allows the reservation of resources for legacy Boot Devices PHA Security SEL ISA adapters and SEL Manager interrupt configuration FRU PCI adapters Preferences Color System Setup Utility Figure 5 SSU Main Window 54 Configuration Software and Utilities Customizing the SSU You can customize the GUI according to your preferences The AF sets these preferences and saves them in the AF INI file so that they take effect the next time you start
208. ue of the current menu item to the next value Enter Activate submenus select feature options and change feature values F9 Display the following message Setup Confirmation Load default configuration now Yes No The Yes button will be highlighted If you press lt Enter gt all Setup fields return to their default values If you press lt ESC gt or select No the server returns to the configuration it had before you pressed lt F9 gt without affecting any existing field values F10 Display the following message Setup Confirmation Save configuration changes and exit now Yes No The Yes button will be highlighted If you press lt Enter gt all current Setup values are saved and the system is reset If you press lt ESC gt or select No the server returns to the configuration it had before you pressed lt F10 gt without affecting any existing values SRPL8 Server System Product Guide 37 Main Menu 38 Default values are in bold typeface Feature Option Description System Time HH MM SS Sets the System Time System Date MM DD YYYY Sets the System Date Legacy Diskette A Disabled Selects the floppy diskette type for drive A 360 KB 5 14 1 2 MB 5 4 720 KB 3 1 44 1 25 MB 3 Y 2 88 MB 3 12 Legacy Diskette B Disabled Selects the floppy diskette type for drive B 360 KB 5 14 1 2 MB 5 4 720 KB 5 4 1 44 1 25 MB 3
209. ufacturer or Importer We hereby certify that this product is in compliance with EU EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC Safety Compliance USA Canada UL 1950 3rd Edition CSA 22 2 No 950 M93 3rd Edition Europe TUV to EN60950 2nd Edition with Amendments A1 A2 A3 A4 International CB Certificate and Report to IEC 950 2nd Edition w A1 A2 A3 A4 and national deviations including EMKO TSE 74 SEC 207 94 207 Electromagnetic Compatibility EMC USA FCC CFR 47 Part 15 Class A Canada IC ICES 003 Class A Europe EN55022 Class A Radiated amp Conducted Emissions EN50082 1 Generic Immunity Standard EN61000 4 2 Immunity level 2 contact discharge level 3 air discharge EN61000 4 3 Radiated Immunuty level 2 EN61000 4 4 Electrical Fast Transient level 2 EN61000 3 2 Line Harmonics International CISPR 22 93 Class A Japan VCCI Class A ITE CISPR 22 B limit IEC 1000 3 2 Line Harmonics New Zealand CISPR 22 93 Class A Australia AS NZS 3548 CISPR 22 93 Class A Electromagnetic Compatibility Notice USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequen
210. untiti e parti taglienti sulle schede e sul telaio E consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate dal produttore Per disfarsi delle pile usate seguire le istruzioni del produttore Il sistema progettato per funzionare in un ambiente di lavoro tipo Scegliere una postazione che sia e Pulita e libera da particelle in sospensione a parte la normale polvere presente nell ambiente e Ben ventilata e lontana da fonti di calore compresa la luce solare diretta e Alriparo da urti e lontana da fonti di vibrazione e Isolata dai forti campi magnetici prodotti da dispositivi elettrici e In aree soggette a temporali consigliabile collegare il sistema ad un limitatore di corrente In caso di temporali scollegare le linee di comunicazione dal modem e Dotata di una presa a muro correttamente installata e Fornito di uno spazio sufficiente ad accedere al cavo di alimentazione del server poich si tratta del modo principale per scollegare l alimentazione del sistema SRPL8 Server System Product Guide 217 ADVERTENCIAS Espanol El usuario debe abstenerse de manipular los componentes de la fuente de alimentaci n de este producto cuya reparaci n debe dejarse exclusivamente en manos de personal t cnico especializado Puede que este producto
211. upport all COM ports on the client system along with any Windows NT 95 compatible modem Server Configuration The DPC console requires that the server s COM2 port be connected to an external modem or directly connected to a serial cable Direct Connect Configuration A null modem serial cable is needed Connect one end of the cable into the COM2 port of the server and the other into a port on the client machine SRPL8 Server System Product Guide 65 Modem Configuration On the client the DPC console uses the Windows application program interface API to determine if a modem is connected and available The DPC Console does not configure the modem it should be preconfigured through Windows For modem support the server must use a Hayes compatible 14400 bps modem The modem must be on the NT hardware compatibility list provided by Microsoft The server modem must be set in autoanswer mode for the DPC console to be able to connect to it Setting Up the Server for the EMP To use the EMP you must configure BIOS with specific settings Enter these settings into the BIOS Server Menu and the Console Redirection Submenu These sections show ALL available options for BIOS settings The two sections on page 66 Server Menu and Console Redirection Submenu describe the settings that MUST be configured to use the EMP Server Menu All EMP related settings occur from the Server Menu Change only the items below all other default s
212. ute limit may cause damage to certain peripheral components Before replacing a power supply in a two power supply configuration you must turn off power to the server 88 Hot Swapping Fans SCSI Hard Drives and Power Supplies Removing a Power Supply CAUTIONS Turn off peripheral devices If the chassis contains only two power supplies turn off all peripheral devices connected to the server Then turn off the server power with the push button on off switch on the front panel Populate all bays Figure 19 shows the far right power supply bay vacant To ensure correct airflow you must populate this bay with a redundant power supply or cover panel The figure is intended to show a power supply bay with the supply removed and not yet replaced not an acceptable configuration for a system during operation See Figure 19 1 Look at the yellow FAIL LEDs on the power supplies to determine which one is defective 2 Pull the power supply handle down to unlock it from the chassis 3 Pull the power supply straight back out of the chassis Set it aside OM07324 Figure 19 Removing a Power Supply A Pull down handle first B Slide power supply out SRPL8 Server System Product Guide 89 Replacing a Power Supply See Figure 19 90 1 2 3 Remove the new power supply from the protective packaging and place it on an antistatic surface Record the model and serial numbers of the power supply in your equipment log
213. utomatically reprograms CMOS to the default settings except for the password Enter Setup and make any changes necessary for example changing the boot device Press F10 to save the new Setup configuration and exit Setup Power off the system Return switch position 5 to the left most default position Reinstall the PCI hot plug cover using the original screws power on the system and resume normal operation Run BIOS Setup or the SSU to verify the correct settings See Chapter 3 SRPL8 Server System Product Guide 183 Password Clear Switch 1 Ensure that the system is powered off Remove the PCI hot plug cover On switch SW4G1 slide or press switch number 6 to the right most position 2 Power on the system Wait for POST to complete and for the messages Password cleared by jumper and Press F2 to enter Setup to appear This automatically clears the password 3 Enter Setup and make any changes necessary for example changing the boot device Press F10 to save the new Setup configuration and exit Setup 4 Power off the system Return switch position 6 to the left most default position 6 Reinstall the PCI hot plug cover using the original screws power on the system and resume normal operation A Recovery Boot Switch 184 1 Ensure that the system is powered off Remove the PCI hot plug cover On switch SW4G1 slide or press switch number 2 to the right most position 2 Ensure that the BIOS diskette i
214. ve or authorized dealer for assistance Solving Problems Hard Disk Drive Activity Light Does Not Light If you have installed one or more hard disk drives in your system check the following e Are the power and signal cables to the drive properly installed e Are all relevant switches and jumpers on the hard drive and adapter board set correctly e Is the onboard IDE controller enabled IDE hard drives only e Is the hard disk drive properly configured gt NOTE Front panel hard disk LED indicates IDE and SCSI devices The hard disk drive activity light on the front panel lights when either an IDE hard disk drive or a SCSI device controlled by the onboard SCSI host controller is inuse This LED does not display CD ROM activity CD ROM Drive Activity Light Does Not Light Check the following e Are the power and signal cables to the CD ROM drive properly installed e Are all relevant switches and jumpers on the drive set correctly e Is the drive properly configured e Is the onboard IDE controller enabled gt NOTE Front panel hard disk LED indicates IDE and SCSI devices The hard disk drive activity light on the front panel lights when either an IDE hard disk drive or a SCSI device controlled by the onboard SCSI host controller is inuse This LED does not display CD ROM activity Network Problems If you have network problems consult the documentation that came with the network board you purchased for this ser
215. ver PCI Installation Tips Some common PCI tips are listed here e Certain drivers may require interrupts that are not shared with other PCI drivers The SSU can be used to adjust the interrupt numbers for PCI devices For certain drivers it may be necessary to alter settings so that interrupts are not shared e Check PCI interrupt interdependencies among slots and onboard devices SRPL8 Server System Product Guide 161 Problems with Application Software If you have problems with application software do the following e Verify that the software is properly configured for the system See the software installation and operation documentation for instructions on setting up and using the software e Try a different copy of the software to see if the problem is with the copy you are using e Make sure all cables are installed correctly e Verify that the I O carrier switches are set correctly See Configuration Switches on page 182 e If other software runs correctly on the system contact your vendor about the failing software e Ifthe problem persists contact the software vendor s customer service representative for assistance Bootable CD ROM Is Not Detected Check the following e Is BIOS set to allow the CD ROM to be the first bootable device e Is the peripheral bay fully seated against the chassis Error and Informational Messages When you turn on the system POST displays messages that provide information abou
216. verkaren Kassera anv nt batteri enligt fabrikantens instruktion varorrus Paristo voi r j ht jos se on virheellisesti asennettu Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin H vit kaytetty paristo valmistajan ohjeiden mukaisesti 152 Upgrading Boardset Components OM11018 Figure 54 Replacing the Lithium Battery A Tab B Positive side up C Battery 1 Observe the safety and ESD precautions at the beginning of this chapter and the additional warning given on page 152 2 Remove the top cover Insert the tip of a small flat bladed screwdriver or equivalent under the plastic tab on the snap on plastic retainer 1 Gently push down on the screwdriver to lift the battery 2 Remove the battery from its socket 3 Dispose of the battery according to local ordinance Remove the new lithium battery from its package and being careful to observe the correct polarity insert it in the battery socket Reinstall the top cover using the original screws 9 Run the SSU to restore the configuration settings to the RTC AUD YE oo SRPL8 Server System Product Guide 153 154 Upgrading Boardset Components 7 Solving Problems This chapter helps you identify and solve problems that might occur while you are using the system Resetting the System To do this Press Soft boot reset which clears system memory and reloads the operating system lt Ctrl
217. ving the Fan Array Housing on page 101 e Memory modules see Removing a Memory Module on page 142 e Processors see Removing a Processor on page 148 3 Remove the ten screws five each side that secure the tray to the chassis 4 Simultaneously rotate the eject insert levers to eject the tray out of the midplane 5 Slide the tray from the chassis Installing the Profusion Carrier Tray See Figure 28 1 Observe the safety precautions warnings and cautions at the beginning of this chapter 2 Carefully position the tray on the guide rails and slide the tray into the chassis A CAUTION Be careful not to pinch the cables coming from the peripheral bay when reinstalling the tray 3 Ensure that the midplane and profusion carrier tray connectors are properly aligned 4 Simultaneously rotate the eject insert levers to mate the tray grand connector with the midplane grand connector Ensure that the lower tray guide engages with the tray support attached to the peripheral bay 5 Use the two screws you removed earlier to secure the tray to the chassis 6 Install the processor retention module 7 Install the processors see page 149 104 Working Inside the System 8 Install the memory modules see page 142 9 Install the fan array housing page 101 10 Install the top cover page 99 and memory module cover page 100 Figure 28 Removing the Profusion Carrier Tray A Screws five B Eject
218. you can define which FRU and SDR areas are to be programmed Additionally you can request information from the user or ask the user to choose which areas to program 74 Configuration Software and Utilities Displaying a Given Area When the utility is run with the d DMI d FRU or d SDR command line flag the indicated area is displayed Each area represents one sensor for each instrumented device in the server If the given display function fails because of an inability to parse the data present or a hardware failure the utility displays an error message and exits Displaying DMI Area Each DMI area displayed is headed with the DMI area designated name In each area each field has a field name header followed by the field in ASCII or as a number Example To display the DMI area type frusdr d dmi and press lt Enter gt Displaying FRU Area The FRU area is displayed in ASCII format when the field is ASCII or as a number when the field is anumber Each FRU area displayed is headed with the FRU area designated name Each field has a field name header followed by the field in ASCII or as a number The board chassis and product FRU areas end with an END OF FIELDS CODE that indicates there are no more data in the area The internal use area is displayed in hex format 16 bytes per line Example To display the FRU area type frusdr d fru and press lt Enter gt Displaying SDR Area The SDR nonvolatile storage area is displayed in the
219. your selections on the separate Management Subsystem System Sensor Control Worksheet on page 202 Enable Disable Enable Disable Enable Disable SMM Enable Event Logging PCI System Error Detection SRPL8 Server System Product Guide 201 Management Subsystem System Sensor Control Worksheet For each sensor control the display includes the choices shown below with blanks for entering values Write in both the sensor control and the values you select This worksheet two pages provides space for a number of sensor controls if you need more space copy these pages to extend your worksheet Item Disable Enable Upper Fatal Upper Warning Lower Warning Lower Fatal Lower Disable Enable Upper Fatal Upper Warning Warning Lower Fatal Disable Enable Upper Fatal Upper Warning Lower Warning Lower Fatal Lower Disable Enable Upper Fatal Upper Warning Warning Lower Fatal Disable Enable Upper Fatal Upper Warning Lower Warning Lower Fatal Lower Disable Enable Upper Fatal Upper Warning Warning Lower Fatal Disable Enable Upper Fatal Upper Warning Lower Warning Lower Fatal 202 Lower Disable Enable Upper Fatal Upper Warning Warning Lower Fatal Equipment Log and Configuration Worksheets Item Item
220. ze DRAM 29 1 3 3 2 Initialize or call POST Memory Manager 2A Clear 512 KB base RAM 2C 1 3 4 1 RAM failure on address line xxxx 2E 1 3 4 3 RAM failure on data bits xxxx of low byte of memory bus 2F Prepare to shadow system BIOS 30 1 4 1 1 RAM failure on data bits xxxx of high byte of memory bus 32 Test processor bus clock frequency 33 Initialize the POST Dispatch Manager 34 1 4 2 1 Test CMOS continued SRPL8 Server System Product Guide 163 Table 16 Port 80 Codes continued POST Code 35 36 37 38 39 3A 3C 3D 40 42 44 45 46 47 48 49 4A 4B 4C 4E 50 52 54 56 58 59 5A 5B 5C 60 62 64 66 67 68 69 6A 164 Beeps 2 2 3 1 Error RAMInitialize alternate chip set registers Warm start shut down Reinitialize the chip set MB only Shadow system BIOS ROM Reinitialize the cache MB only Autosize cache Configure advanced chip set registers Load alternate registers with CMOS values new Set Initial processor speed new Initialize interrupt vectors Initialize BIOS interrupts Initialize run time devices Check ROM copyright notice Initialize manager for PCI Option ROMs Check video configuration against CMOS Initialize PCI bus and devices Initialize all video adapters in system Display QuietBoot screen Shadow video BIOS ROM Display copyright notice Display processor type and speed Test keyboard Set key click if enabled Enable keyboard Test for unexpected interrupts Initialize PO