1. The Wired Thermostat is the Master or perhaps a different Wireless Thermostat so the setpoint levels and mode changes Heat Cool etc made at the Wired Thermostat manually following the Auto schedule or via another INSTEON controller are being sent to the Wireless for display When using only batteries the Wireless Thermostat will go to sleep and not responded to signals from other INSTEON devices The unit wakes up every minute and checks for changes If differences are detected the display is updated and communicated to linked devices Page 25 of 27 locations Press the Master button on the Wireless Thermostat so that it becomes the master and its mode and setpoints are controlling the Wired Thermostat Add an AC adapter and the unit will stay on and awake all the time Use an AC adapter for continuous temperature and humidity monitoring Rev 1 21 2014 8 36 AM Certification and Warranty FCC and Industry Canada Compliance Statement This device complies with part 15 of the FCC Rules and Industry Canada license exempt RSS 210 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le present appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorise aux d
2. 75 F 24 C Sleep 11 00PM Auto 60 16 C 80 F 27 C Note To exit program setup mode press Mode button once Fan and Hold Button Operations Fan button operations e The Fan button is only functional when INSTEON Wireless Thermostat is linked to an INSTEON Thermostat e The Fan button cycles between Auto and Always On e On the display it simply indicates the text Fan Always when selected There is no text for Auto HEATING HEATING 10 10 FAN ALWAYS Always On Auto INSTEON Page 9 of 27 Rev 1 21 2014 8 36 AM Hold button operations e The Hold button is only functional in Auto Program mode e The Hold button overrides a preprogrammed mode until Hold is turned off HEATING HEATING HOLD Hold On Hold Off IMPORTANT e While Hold is enabled the next preprogrammed time that comes in Preprogrammed Auto Mode will be ignored e While Hold is enabled the preprogrammed time notations are not shown i e Wake Leave Return and Sleep e Hold can be remotely enabled disabled from an INSTEON controller Master Button Operation First press and hold Makes the local INSTEON Wireless Thermostat the master temperature controller e To perform this press and hold Master button for 3 seconds INSTEON Wireless Thermostat will beep once e Release Note This is only valid if INSTEON Wireless Thermostat is linked to a INSTEON Thermostat 8 30 om gt 28 lb HASTER COOL 1 1 82 Oc 7 j Ii Li amp HUMIDIT
3. operate the equipment DECLARATION OF CONFORMITY Hereby INSTEON declares that this device is in compliance with the essential requirements and other relevant provisions of the following Directives 1 Electromagnetic Compatibility Directive 2004 108 EC 2 Hazardous Substance Directive 2005 95 EC Technical data and copies of the original Declaration of Conformity are available and can be obtained from INSTEON 16542 Millikan Ave Irvine CA USA User Information for Consumer Products Covered by EU Directive 2002 96 EC on Waste Electric and Electronic Equipment WEEE This document contains important information for users with regards to the proper disposal and recycling of INSTEON products Consumers are required to comply with this notice for all electronic products bearing the following symbol Environmental Information for Customers in the European Union European Directive 2002 96 EC requires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separately from regular household waste streams It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities Correct disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed infor
4. 36 AM 2 Press Program to exit calibration mode Advanced 2 Stage Heating or Cooling Systems INSTEON Wireless Thermostat does not have the ability to operate first or second stages of Heat or Cool directly but can instruct INSTEON Thermostat to operate the HVAC First and second stage of Heat or Cool engages under the following conditions when INSTEON Thermostat is connected to the HVAC e INSTEON Thermostat setpoint is set at 5 F or C or more below ambient in Cool mode and 5 F or C or more above ambient in Heat mode Heat mode setpoint is 80 ambient is 72 first and second stage engaged Cool mode setpoint is 78 ambient is 84 first and second stage engaged e INSTEON Thermostat has been active in Heat or Cool for longer than 10 minutes and did not reach setpoint Heat mode ran for 10 minutes and did not reach setpoint second stage engaged Cool mode ran for 10 minutes and did not reach setpoint second stage engaged Note It is possible for INSTEON Thermostat to occasionally engage and disengage second stage during a single heating or cooling cycle as variables are met Factory Reset E If you want to reset INSTEON Wireless Thermostat to its factory default settings follow instructions below Note If you choose to reset INSTEON Wireless Thermostat to its factory default settings it is important that you remove scene memberships from all controllers Otherwise controllers will retry commands repetitively c
5. of the possibility of such damages Some states do not allow limitations on how long an implied warranty lasts and or the exclusion or limitation of damages in which case the above limitations and or exclusions may not apply to you You may also have other legal rights that may vary from state to state Protected under U S and foreign patents see www insteon com patents Copyright 2013 INSTEON 16542 Millikan Ave Irvine CA 92606 866 243 8022 www insteon com INS TE ON Page 27 of 27 Rev 1 21 2014 8 36 AM
6. the INSTEON Thermostat the Wireless Thermostat still reads master When the Wireless Thermostat is linked to a Wired Thermostat it will not directly control other linked devices based on temperature or humidity When an AC adapter is used the temperature and humidity settings are changing rapidly When I move the Wireless Thermostat to a cold room the temperature does not update The Wireless Thermostat will not go into Master Mode The Wireless Thermostat or Wired Thermostat goes out of INS TEON software of all changes etc Both units were calibrated at the factory prior to shipment Other factors could contribute to different readings The Wireless Thermostat does not have a back up clock that keeps the time The Wireless Thermostat will wake up and synchronize data with the Wired Thermostat Every 15 minutes If it detects a temperature change If the up down temperature buttons are pressed This is normal Noise from the AC adapter is affecting the Wireless Thermostat s electronics The unit will update the display every minute Also the case and electronics of the unit will hold the warmth of the previous room for up to an hour The air flow into the Wireless Thermostat may be blocked The Wired Thermostat only allows up to two Wireless Thermostats and will reject three or more The two units are too far from each other and unable to communicate with each other Page 24
7. time information will be provided by INSTEON Thermostat Note Colors indicate element that is presently blinking during setting procedure First press of Time Sensor Second press of Time Sensor Hours settings Minutes settings e Up Down arrows cycle through time in 1 e Up Down arrows cycle through time in 1 hour increments minute increments e Pressing and holding Up Down arrows e Pressing and holding Up Down arrows cycles through faster cycles through faster Note AM PM changes automatically as needed INSTEON Page 7 of 27 Rev 1 21 2014 8 36 AM 0 30 ww 9 30 om Third press of Time Sensor Clock Format setting 12 or 24 Hour clock e Entire time line blinks e Up Down arrows cycle between 12 and 24 hour clock format Note AM PM is not displayed when in 24 hour format 8 30 PM ci 30 Program Button Operation e The Program button allows you to set up the various preprogrammed modes Wake Leave Return and Sleep e Goto the next step by pressing Program again e Exit Program setup by Letting it time out after 4 minutes Pressing Mode button IMPORTANT Once you have added INSTEON Wireless Thermostat to a scene in INSTEON Thermostat as a wireless temperature zone the Program button will no longer function All program controls will be performed on the INSTEON Thermostat Note Text colors below indicate element that is presently blinking during setting procedure First press of Program Selects from availa
8. INSTEON Wireless Thermostat Owner s Manual 2132 232 2441ZTH US 2732 432 EU 2732 532 AUS NZ Rev 1 21 2014 8 36 AM N S T E c N Page 1 of 27 What s in the Box INSTEON Wireless Thermostat Button Overview INSTEON Wireless Thermostat Operation and Programming Mode Button Operation Energy Button Operation Set Button Operation Time Sensor Button Operations Program Button Operation Fan and Hold Button Operations Master Button Operation Optional Accessories Waterproof Temperature Sensor 2433A3 Power Supply Installation Preparation Test Operation Adding INSTEON Wireless Thermostat to an INSTEON Thermostat INSTEON Programming Add INSTEON Wireless Thermostat as a Controller Remove INSTEON Wireless Thermostat as a Controller User Setup Mode Overview User Setup Mode Temperature and Humidity Calibration Modes Advanced 2 Stage Heating or Cooling Systems Factory Reset Specifications Troubleshooting Certification and Warranty FCC and Industry Canada Compliance Statement Limited Warranty Limitations INSTEON Page 2 of 27 Rev 1 21 2014 8 36 AM OONNOOGO A O What s in the Box e INSTEON Wireless Thermostat e Quick Start Guide e Tabletop stand removable for wall mounting INS TE ON Page 3 of 27 Rev 1 21 2014 8 36 AM INSTEON Wireless Thermostat Button Overview Temperature s of external Current sensor and or wireless temperature Cool setpoint inermostat INSTEON Wireless Th
9. Y HUMIDITY Before pressing Master button After pressing and holding Master button e Notice that the left remote sensor is currently e Notice that the left remote sensor is no the Master temperature controller longer the Master temperature controller e The local INSTEON Wireless Thermostat is now the Master controlling temperature Note If no INSTEON scene is programmed to an INSTEON Wireless Thermostat pressing and holding for 3 seconds will have no function INSTEON Page 10 of 27 Rev 1 21 2014 8 36 AM Optional Accessories Waterproof Temperature Sensor 2433A3 INSTEON Waterproof Temperature Sensor is an external sensor that wires to your INSTEON Wireless Thermostat When connected the thermostat s LCD display will show the sensor readings in small digits above the thermostat s temperature Waterproof Temperature Sensor can be extended up to 100 with 22 AWG wire It s ideal for n monitoring and maintaining constant temperatures in environments like pools spas aquariums and ponds Power Supply INSTEON Wireless Thermostat includes a connection for an AC power supply Any generic AC DC adapter that has a 5 7 5V and 200mA output will work Do not use an adapter greater than 7 5V to avoid damaging the thermostat When connected to external power INSTEON Wireless Thermostat will automatically switch from battery power to external power batteries can remain installed and will stay on and awake all
10. again to enter Cool mode 2 Tap the Up or Down arrow several times until setpoint is 1 below ambient INSTEON Wireless Thermostat will call for Cooling Cool will change to Cooling blink for 3 seconds and then turn on steady No A C activity will take place at this time only display changes 3 Tap the Up or Down arrow until you reach a desirable cool temperature setpoint Auto Mode Test 1 Tap Mode button once to enter Auto mode Note that your Heat and Cool setpoints were set in previous steps unless you did not have a minimum 2 gap between settings Tap Up once to increase both Heat and Cool setpoints by 1 Tap Down once to decrease both Heat and Cool setpoints by 1 Tap Mode once to enter Programmed Auto mode Indicated by Auto at bottom and relevant time of day to right of Heat Cool set temps 5 Tap Mode twice to return to Off mode 22y Adding INSTEON Wireless Thermostat to an INSTEON Thermostat Link INSTEON Wireless Thermostat to INSTEON Thermostat to provide a portable thermostat wherever you want temperature control You can add up to two INSTEON Wireless Thermostats to an INSTEON Thermostat 1 Press and hold INSTEON Wireless Thermostat Set button INSTEON Wireless Thermostat will beep and its Set LED will blink green 2 Press and hold INSTEON Thermostat Set button INSTEON Page 12 of 27 Rev 1 21 2014 8 36 AM INSTEON Thermostat will beep then double beep INSTEON Wireless Thermostat will double beep 3 Te
11. ange default INSTEON Page 14 of 27 Rev 1 21 2014 8 36 AM e Group 2 Heating mode change e Group 3 Dehumidifiation high humidity setpoint e Group 4 Humidification low humidity setpoint 4 Press and hold responder Set button INSTEON Wireless Thermostat will double beep upon completion LED will turn off 8 30 PM 16 DA 41 82 HEATING HUMIDITY Upon entering Add a Scene mode COOLING 1 f Upon entering Remove a Scene mode defaults to Cooling mode HEATING l L HUMIDITY I mM HUMIDITY LCD displays when using Up or Down buttons to select from among the 4 controller groups User Setup Mode Overview IMPORTANT Once you have added INSTEON Wireless Thermostat to INSTEON Thermostat the Program and Time Sensor buttons will no longer perform their initial functions All program and time controls will be performed on the INSTEON Thermostat To access the Program and Time Sensor buttons again you must remove INSTEON Wireless Thermostat from INSTEON Thermostat Program and Time Sensor buttons can be used to wake INSTEON Wireless Thermostat up from its Rev 1 21 2014 8 36 AM N S T E C N Page 15 of 27 battery saving mode to retrieve any updates from INSTEON Thermostat Press and hold Program button for 3 seconds or more to enter User Setup Mode Normal Operations User Setup Mode Program Button Time Sensor Button Display On Time Frogram B
12. ble pre program modes Up Down arrows cycle through Wake Leave Return and Sleep NOTE e Energy is not a part of this option e Once a preprogrammed mode is selected that item remains displayed throughout to indicate the mode you are programming e The current mode settings are displayed on the thermostat at each setup step WAKE LEAVE ARETUAW SLEEP Second press of Program Start Time e Up Down arrows cycle through time in 15 minute increments Note when pressing the Down arrow if you come within 15 minutes of another preprogrammed mode time you will not be able to increase the time any further e Pressing and holding Up Down arrows cycles through faster Note AM PM changes automatically as needed INSTEON Page 8 of 27 Rev 1 21 2014 8 36 AM 630 m Note The start of one program mode is also the end of the previous program mode Third press of Program Fourth press of Program Cool setpoint Heat setpoint e Up Down arrows cycle through temperature Up Down arrows cycle through temperature e Press and hold scrolls through temperatures Press and hold scrolls through temperatures COOL HEAT 16 Fifth press of Program Restarts the process to program another Mode Day NOTE The four modes come preprogrammed The defaults are for all days Day Thermostat Heat Cool Start Time l Modes Mode Setting Setting Wake 6 00AM Auto 65 F 18 C 75 F 24 C Leave 8 30AM Auto 60 F 16 80 F 27 C Return 5 00PM Auto 65 F 18
13. dity Mode will default to OFF Battery segment should show full with fresh batteries Time will become active and show 12 00PM default 4 Snap INSTEON Wireless Thermostat into the supplied tabletop stand or mount safely to a wall Test Operation INSTEON Wireless Thermostat does not directly control the HVAC system Instead INSTEON Wireless Thermostat communicates via RF to INSTEON Thermostat which is directly in contact to the wiring controlling the HVAC system Before adding INSTEON Wireless Thermostat as a responder or controller of INSTEON Thermostat perform the following tests these will help familiarize you with INSTEON Wireless Thermostat Keep in mind you are not yet sending any communication to any INSTEON device The INSTEON Wireless Thermostat is presently a standalone device Note While testing the display will change but no HVAC operations will take place INSTEON Wireless Thermostat defaults 5 minutes delay between cycling the AC compressor Heating Mode Test 1 Press Mode button once to enter Heat mode 2 Tap the up or down arrow several times until setpoint is 1 above ambient INSTEON Wireless Thermostat will call for Heat Heat will change to Heating blink for 3 seconds and then turn on steady No furnace activity will take place at this time only display changes 3 Tap the Up or Down arrow until you reach a desirable heat temperature setpoint below ambient Cooling Mode Test 1 Tap Mode button once
14. e setpoint is lower that the actual temperature the element reads Heat Rev 1 21 2014 8 36 AM COOL RETURN RETURN HEATING HEAT j ENERGY From Programmed Auto Mode e Both Heat and Cool setpoints changed as specified e Default setback is 4 e Notice that Heating is active on the left but not on the right since the setpoint is lower than the current temperature the element reads Heat Note Onscreen text displaying Heat changes to Heating and Cool changes to Cooling to indicate HVAC system is active Set Button Operation The Set button adds and removes INSTEON Wireless Thermostat from INSTEON scenes It functions like the Set button on other INSTEON devices Time Sensor Button Operations e The Time Sensor button allows the user to set the time and clock format e Button cycles among hour minute and 12 24 hour format Note When added to a scene with INSTEON Thermostat INSTEON Wireless Thermostat automatically retrieves time settings from INSTEON Thermostat e Up Down arrows cycle through the available options e Goto the next Time Sensor step by pressing Time Sensor button again e Exit Time Sensor setup by Letting it time out after 4 minutes Pressing Mode button IMPORTANT Once you have added INSTEON Wireless Thermostat to a scene in INSTEON Thermostat as a wireless temperature zone the Time Sensor button will allow you to change time format 12 or 24 hour but
15. ergy Button Operation The Energy button designated with the leaf is a quick efficient energy saving option When you press the Energy button INSTEON Wireless Thermostat will adjust the Heat and Cool setpoints by a specified value The default value is 4 from the current setting but can be changed via home control software such as HouseLinc When you exit Energy mode it will revert back the 4 that was changed upon entry The unit remains in Energy mode until the Energy button is pressed again Up Down arrows adjust the temperature setpoint based on the mode you are in RETURN ENERGY From Off Mode e Energy button does nothing because the system is off at maximum energy savings already e When Energy appears on the screen for Auto Cool and Heat Modes the 4 setback is engaged RETURN HEATING From Heat Mode Heat setback as specified Default setback is 4 less Notice that Heating is active on the left but not on the right since the setpoint is lower that the actual temperature the element reads Heat COOL RETURN RETURN ENERGY From Cool Mode e Cool setback as specified e Default setback is 4 more NS TEON 82 HEATING RETURN From Auto Mode Page 6 of 27 Both Heat and Cool setpoints changed as specified Default setback is 4 more for Cooling and 4 less for Heating Notice that Heating is active on the left but not on the right since th
16. ermostat Programmed auto state S 8 30 wm 58 lb Time Humidity level Heat setpoint Current thermostat The gray buttons mode MASTER are under the Off Auto A INSTEON Heat or Cool Thermostat door 9 8 7 6 5 4 3 1 Up Down adjusts the temperature setpoint based on the current mode 2 Mode allows the user to select the current operational mode of the HVAC system It cycles between Off Heat Cool Auto and Programmed Auto 3 Energy button is a quick option that saves energy and money When pressed it sets back the setpoint by a specified value The default value is 4 from the current setting To change the default offset value to be a value other than 4 you must use software such as HouseLinc 4 Hold overrides a pre programmed mode 5 Fan cycles between Auto and Always On 6 Master makes this device the master temperature controller Pressing and holding Master does not alter any scene or screen settings It just defines this INSTEON Wireless Thermostat as the master temperature controller 7 Time Sensor button allows you to set the date and time It cycles between hour minute and time format 8 Program button allows you to setup the various pre programmed user modes 9 Set button adds and removes INSTEON Wireless Thermostat from scenes It functions like the Set button on other INSTEON devices N S i i E C N Page 4 of 27 Rev 1 21 2014 8 36 AM INSTEON Wireless Thermostat Operation and Programmin
17. eux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radiolectrique subi mme si le brouillage est susceptible d en compromettre le fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15B of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio and television reception However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or relocate the receiving antenna of the device experiencing the interference Increase the distance between this device and the receiver Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user s authority to
18. g Mode Button Operation ILE HEATING MASTER HUMIDITY Off Mode Heat Mode e No setpoints are shown e Only Heat setpoint is shown e Up Down arrows do not do anything e Up Down arrows change Heat setpoint e Heat setpoint range 35 95 F 2 C 36 C HEATING HUMIDITY Cool Mode Auto Mode e Only Cool setpoint is shown e Both Cool and Heat setpoints are shown e Up Down arrows change Cool setpoint e Up Down arrows increase or decrease e Cool setpoint range 37 97 F 4 C 38 C values by the same amount HUMIDITY Programmed Auto Mode e The active program mode is indicated by one of four annotations Wake Leave Return or Sleep e The annotation Wake Leave Return or Sleep is not displayed in the other four modes Off Heat Cool or Auto e Both Cool and Heat setpoints are shown e Up Down arrows increase or decrease values by the same amount e When the thermostat moves to the next time period the setpoints will be adjusted accordingly Note e To adjust the gap between setpoints in Auto mode press Mode to select Heat and set the temperature you desire Press Mode again to select Cool and set the temperature you desire Press Mode a third time to return to Auto the settings will reflect your changes N S i i E N Page 5 of 27 Rev 1 21 2014 8 36 AM e f you set Heat and Cool to the same temperature setpoint Heat will automatically move down 2 the minimum allowable gap En
19. il it beeps INSTEON Wireless Thermostat will beep INSTEON Wireless Thermostat Set LED will blink red LCD display indicates the group you are removing a scene from default is Cooling Double tap Set button 4 Press and hold Set button again Do not let go of Set button Device will blink all segments and emit a long beep 5 When blinking beeping stops release Set button Device goes into factory reset for about 10 seconds and will perform a series of self tests Device will return to normal operations and display screen returns to normal 6 If INSTEON Wireless Thermostat displays a two digit error code instead of the ambient temperature remove batteries wait a few seconds then reinstall If problem persists call INSTEON Support Line at 800 762 7845 Specifications General Brand manufacturer INSTEON 2441ZTH US Can Manufacturer product number 2732 432 EU 2732 532 AUS NZ 813922 010824 US Can UPC 813922 012873 EU 813922 012880 AUS NZ INS TE ON Page 21 of 27 Rev 1 21 2014 8 36 AM Dual color blinks red or green during setup LED brightness N A Commands supported as controller On Off Up to 150 Feet 50m open air No RF only device INSTEON device category 0x05 all frequencies INSTEON device subcategory 2732 432 869 MHz 2732 532 921 MHz A A A A A N A A A a Z lt Zz 2 lt 1 KIKI KIL KT KCK X h k ee ee ee Ce ee ee ee I ee ee ee olololololololo xs nimiotila 2 2 2 8 5 8
20. ltri principi sanciti dalla Direttiva 1999 5 CE Norsk Norwegian Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU direktiv 1999 5 EF Suomi Finnish Tama laite tyttaa direktiivin 1999 5 EY olennaiset vaatimukset ja on siin asetettujen muiden laitetta koskevien m r ysten mukainen Dansk Danish Dette udstyr er i overensstemmelse med de v sentlige krav og andre relevante bestemmelser i Direktiv 1999 5 EF Polski Polish Urz dzenie jest zgodne z og lnymi wymaganiami oraz szczeg lnymi warunkami okreslonymi Dyrektyw UE 1999 5 EC Limited Warranty Seller warrants to the original consumer purchaser of this product that for a period of two years from the date of purchase this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owners Manual This warranty shall not apply to defects or errors caused by misuse or neglect If the product is found to be defective in material or workmanship or if the product does not perform as warranted above during the warranty period Seller will either repair it replace it or refund the purchase price at its option upon receipt of the product at the address below postage prepaid with proof of the date of purchase and an explanation of the defect or error The repair replacement or refund that is provided for above shall be the full extent of Seller s liability with
21. mation about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased the product DECLARATION OF CONFORMITY TO R amp TTE DIRECTIVE 1999 5 EC for the European Community Switzerland Norway Iceland and Liechtenstein Product category general consumer category 3 English This equipment is in compliance with the essential requirements and other relevant provisions of the European R amp TTE Directive 1999 5 EC Deutsch German Dieses Ger t entspricht den grundlegenden Anforderungen und den weiteren entsprechenden Vorgaben der Richtlinie 1999 5 EU Nederlands Dutch Dit apparaat voldoet aan de essentiele eisen en andere van toepassing zijnde bepalingen van de Richtlijn 1999 5 EC Svenska Swedish Denna utrustning star verensst mmelse med de v sentliga egenskapskrav och vriga relevanta bestammelser som framg r av direktiv 1999 5 EG Fran ais French Cet appareil est conforme aux exigences essentielles et aux autres dispositions pertinentes de la Directive 1999 5 EC Espanol Spanish Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directiva 1999 5 CE INSTEON Page 26 of 27 Rev 1 21 2014 8 36 AM Portugu s Portuguese Este equipamento esta em conformidade com os requisitos essenciais e outras provis es relevantes da Directiva 1999 5 EC Italiano Italian Questo apparato conforme ai requisiti essenziali ed agli a
22. n lock enable disable OFF default a Up arrow ra b Down arrow OFF e Sub mode 08 Programming lock enable disable OFF default a Up arrow ON b Down arrow OFF ON OF e Sub mode 09 Activation delay default is 5 minutes a Up arrow Increase activation delay ad b Down arrow Decrease activation delay time c Range 2 to 20 minutes ON OF 3 When finished press and hold Program button to exit Temperature and Humidity Calibration Modes Note Use a calibrated temperature or humidity source when adjusting INSTEON Wireless Thermostat 1 Press and hold the Program button 2 Tap Time Sensor to enter Temperature Calibration Mode 3 Tap Mode to step among internal temperature calibration I humidity calibration and external INSTEON Page 18 of 27 Rev 1 21 2014 8 36 AM temperature calibration modes E Internal Temperature Calibration e appears on right side of screen e The top left number 77 in example is the current reading according to the temperature sensor e The top right number 14 in example is the current offset represents 1 4 e These numbers can change while this screen is displayed even though the primary temperature does not change they are floating point calculations 1 Tap Up or Down arrows to adjust the displayed temperature to match the calibrated source i Each press results ina 1 F 0 5 C change ii The calculation using example numbers below is 78 77 1 4 iii The offset ra
23. nge is from 10 to 10 actual s WT OY Humidity Calibration Mode 1 Once in Setup Mode for temperature calibration step 1 above tap Mode button to step between temperature calibration and humidity calibration 2 Press the Up or Down arrow to select the current humidity level e The top left number 40 in example is the current reading according to the humidity sensor e The top right number 92 in example is the current offset represents 9 2 e These numbers can change while this screen is displayed even though the primary humidity level does not change they are floating point calculations o Each press results in a 1 humidity change o The calculation using example numbers below is 31 40 9 2 and 42 40 1 7 o The offset is from 10 to 10 3 Press the MODE button to calibrate the external temperature sensor or press Program to exit calibration mode Ji 4e HUMIDITY HUMIDITY External Temperature Calibration e f you are using a Waterproof Temperature Sensor use this mode to calibrate its external temperature readings e E appears on right side of screen 1 Tap Up or Down arrows to adjust the displayed temperature to match the calibrated source i Each press results in a 1 F 0 5 C change ii The calculation using example numbers below is 78 77 1 4 ii The offset range is from 10 to 10 actual s v If no external sensor is installed EE will be displayed instead INSTEON Page 19 of 27 Rev 1 21 2014 8
24. of 27 Use an AC adapter sold separately to power INSTEON Wireless Thermostat Use the Calibration feature to adjust either the temperature and humidity so the two unit match and the temperature feels about right If linked to an INSTEON Wired Thermostat the Wireless Thermostat will pull the current time temperature and settings every 15 minutes During the synchronization the Master icon will clear on the Wireless Thermostat Have your Wired Thermostat be the controller of other devices based on temperature and humidity Be sure that your AC adapter is outputting between 5 to 7 5 volts Change to a better quality AC adapter After about one hour the temperature display will stabilize and show an accurate figure Be sure to use the included stand or mount the unit on a wall to get good air flow Unlink the Wireless Thermostat s or reset all units and re link Use INSTEON Range Extenders Access Points or Dual Band modules between the two Rev 1 21 2014 8 36 AM Master Mode The temperature setpoints and the Mode changes from what it was Set to Computer software or other controller can t retrieve the Wireless Thermostat s data Temperature Humidity Setpoints The Wireless Thermostat seems slow to update the sensed temperature and humidity INSTEON and check in for updates If the two units can t communicate each will go out of the Mater mode after 30 to 60 minutes
25. ote Do not set to ON unless you are connected to a power supply or the batteries will drain very rapidly e Sub mode 02 Humidity low setpoint humidification 30 default a Up arrow Increase humidity setpoint b Down arrow Decrease humidity setpoint c Press and hold arrow buttons to scroll d Range 0 to 79 humidity high setpoint will automatically adjust to be 20 than humidity low setpoint e Sub mode 03 Humidity high setpoint dehumidification 90 default a Up arrow Increase humidity setpoint b Down arrow Decrease humidity setpoint c Press and hold arrow buttons to scroll d Range 20 to 99 cannot come within 20 of humidity low setpoint a 03 of e Sub mode 04 Temperature format select C or F F default a Up arrow C b Down arrow F gi cH F L INSTEON Page 17 of 27 Rev 1 21 2014 8 36 AM e Sub mode 05 Chose whether the Internal or External temperature sensor initiates commands Internal default a Up arrow External b Down arrow Internal c Note that when using two INSTEON Wireless Thermostats with External temperature sensor enabled each INSTEON Wireless Thermostat will only display its local reading and the INSTEON Thermostat s reading INSTEON Thermostat will display both INSTEON Wireless Thermostats readings e Sub mode 06 Beep on button press enable disable OFF default a Up arrow ON b Down arrow OFF ON OF e Sub mode 07 Butto
26. reating network delays Follow the instructions in Removing INSTEON Wireless Thermostat as an INSTEON Responder above for each scene controller of which INSTEON Wireless Thermostat is a member Factory reset changes e INSTEON is reset all scene memberships are removed e Day time is changed to 12 00PM e Programming times temperatures and other settings are reset to their default values Factory reset does not change e Temperature offset e Humidity offset Factory Reset 1 Open INSTEON Wireless Thermostat and remove a battery 2 Wait 10 seconds 3 While pressing and holding the Set button reinsert the removed battery Do not let go of Set button Device will blink all segments and emit a long beep for about 10 seconds INSTEON Page 20 of 27 Rev 1 21 2014 8 36 AM 4 When blinking beeping stops release Set button Device goes into factory reset for 10 seconds and will perform a series of self tests Device will return to normal operations and display screen returns to normal 5 If INSTEON Wireless Thermostat displays a two digit error code instead of the ambient temperature remove batteries wait a few seconds then reinstall If problem persists call INSTEON Support Line at 800 762 7845 Factory Reset Option 2 1 Press and hold INSTEON Wireless Thermostat Set button until it beeps INSTEON Wireless Thermostat will beep INSTEON Wireless Thermostat Set LED will blink green 2 Press and hold INSTEON Wireless Thermostat Set button again unt
27. respect to this product For repair or replacement during the warranty period call the INSTEON Support Line at 866 243 8022 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to INSTEON ATTN Receiving 16542 Millikan Ave Irvine CA 92606 5027 Limitations The above warranty is in lieu of and Seller disclaims all other warranties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the above warranty and disclaimer Home automation devices have the risk of failure to operate incorrect operation or electrical or mechanical tampering For optimal use manually verify the device state Any home automation device should be viewed as a convenience but not as a sole method for controlling your home In no event shall Seller be liable for special incidental consequential or other damages resulting from possession or use of this device including without limitation damage to property and to the extent permitted by law personal injury even if Seller knew or should have known
28. roller to Groups 1 4 When it is added as a controller of an INSTEON Thermostat the setpoints between INSTEON Wireless Thermostat and INSTEON Thermostat will always be matched When it is not added as a controller to a INSTEON Thermostat the setpoints are local only Note Humidity levels are taken from the local device only they are not shared or matched among thermostats 1 Press and hold INSTEON Wireless Thermostat Set button until it beeps INSTEON Wireless Thermostat Set LED will blink green 2 Tap Up or Down arrows to select from Groups 1 4 to add to a scene e Group 1 Cooling mode change default e Group 2 Heating mode change e Group 3 Dehumidification high humidity setpoint e Group 4 Humidification low humidity setpoint 3 Adjust scene responder such as OutletLinc with connected humidifier to the state you want when scene is activated e g 50 25 or even off 4 Press and hold responder Set button until it double beeps or its LED flashes INSTEON Wireless Thermostat will double beep upon completion LED will turn off 5 Confirm scene addition was successful by raising or lowering INSTEON Wireless Thermostat setpoint After INSTEON Wireless Thermostat changes to active mode set in step 2 above responder will toggle between the scene on level and off 6 To add more responders to the scene repeat steps 1 5 for each additional responder Group EF is a hexadecimal representation of Group 254 and can only be config
29. s 9 gt D gt 5 MPIS15 1 02 cC 21qH 5 S 2 31 3 4 lt 135 2 Mlcle oO op 9 3 3 a 8 D ia la l3l S 5 o V 2 GO O1g D al eal B D 10 2ej lt jg DS M Z Mechanical Mounting Tabletop stand or wall mount N A Yes 4 position White Wires Pa Screw clamp connections Case color Set button UV stabilized ABS Beeper Yes Plastic Beep on button press Optional off by default LED 1 red green dual color Dimensions 5 7 x 3 6 x 1 3 14 5cm x 9 1cm x 3 4cm Weight 0 53 lbs 8 4 oz 240g without batteries Operating environment Indoors 4 to 40 C 39 to 104 F 0 90 relative humidity Operating temperature range Operating humidity range Storage temperature range 20 to 70 C 4 to 158 F Electrical N S i i E N Page 22 of 27 Rev 1 21 2014 8 36 AM 2 AA cells quality alkaline recommended 4 5 to 7 5 volts DC 200mA vo 22 micro Amps on battery power Standby power consumption Stenby poner consumption 20mA on external power not in sleep mode FCC ID Pat 15B amp 15C and IC RSS 210 Issue 8 US Can Certifications ETSI EN 300 220 1 amp 220 2 ETSI EN 301 489 1 amp 489 3 Eu AS NZ 4268 C Tick N16509 aie WEEE RoHS All models C Tick N16509 Aus NZ model Safety approval s N A low voltage device Troubleshooting After powering up or a factory lt didn t boot up fully Remove batteries from INSTEON reset INSTEON Wireless Wireless Thermos
30. st the scene by pressing and holding INSTEON Wireless Thermostat s Master button When properly synchronized pressing the Master button on one INSTEON Wireless Thermostat will illuminate the Master segment on that same screen Additionally the present room temperature of the Wireless Thermostat will be displayed in position 1 as temperature segments at the display s top center A visual inspection of each display will reveal Master status of INSTEON Thermostat or INSTEON Wireless Thermostat Note Only INSTEON Thermostat is directly wired to the HVAC system If you plan on operating multiple INSTEON Wireless Thermostats you must have an INSTEON Thermostat installed to control the HVAC INSTEON Programming Add INSTEON Wireless Thermostat as a Controller INSTEON Wireless Thermostat can be set up to control other INSTEON devices or trigger software events when there is a change The following INSTEON Wireless Thermostat changes can be configured as acontroller note that when linked to an INSTEON Thermostat these commands will not function Group 1 Cooling mode change scene control Group 2 Heating mode change scene control Group 3 Dehumidification high humidity setpoint scene control Group 4 Humidification low humidity setpoint scene control Group EF Broadcast on any change notification group for linked software controllers NOTE An INSTEON Wireless Thermostat can also be added to a scene as a cont
31. tat wait a few Thermostat displays a two digit seconds then reinstall If error code instead of the ambient problem persists call the temperature INSTEON Support Line replaced my INSTEON Wireless The INSTEON for Hub app Update the INSTEON I D on Thermostat with a new one but communicates via INSTEON both the Hub and the INSTEON now the INSTEON for Hub app D s They are still trying to for Hub app with your new doesn t recognize it communicate to the old thermostat s I D thermostat s I D My INSTEON Wireless At the top of each hour and 15 For an immediate update press Thermostat temperature reading 30 and 45 past the INSTEON the temperature up or down is taking a long time to update on Wireless Thermostat will wake up button my INSTEON Thermostat and synchronize the readings display with the INSTEON Thermostat display INSTEON Wireless Thermostat s Battery life depends on individual Change INSTEON Wireless battery life seems very short settings such as LED backlight Thermostat settings to reduce display on time notifying battery consumption INSTEON Page 23 of 27 Rev 1 21 2014 8 36 AM The displayed temperature and humidity don t seem accurate When the Wireless thermostat is placed near the Wired Thermostat the temperature and humidity readings are different When the power is removed the clock settings are lost When you change the Master mode from the INSTEON Wireless Thermostat to
32. the time If external power is lost INSTEON Wireless Thermostat will switch back to battery power Install power supply as follows Power supply 1 Open the back of INSTEON Wireless Thermostat Locate the wiring block for the power supply It should be the two left screws Use a flathead screwdriver to loosen screws Route power supply cable through hole in back of thermostat case Connect power supply s exposed copper wire strands to terminal block making sure the wires are in the correct positive negative polarities Tighten screws Close back case INSTEON Wireless Thermostat will automatically turn on and switch to external power h d m Sh h v w A A oOo eo Ra ed Installation E CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference Preparation Follow these steps to properly install INSTEON Wireless Thermostat This thermostat will mainly be used on a tabletop wall mounting is optional 1 Make sure the location that you have selected for INSTEON Wireless Thermostat will not be affected by daily sun movement or be in direct line of sight of a nearby HVAC vent or fan 2 Insert 2 AA batteries into INSTEON Wireless Thermostat high quality alkaline batteries recommended 3 Close the INSTEON Wireless Thermostat cover INSTEON Page 11 of 27 Rev 1 21 2014 8 36 AM After a few seconds INSTEON Wireless Thermostat will display ambient temperature and humi
33. ured using software If the responder is a multi scene device such as a KeypadLinc tap the scene button you wish to control until its LED is in the desired scene state on or off INS TE ON Page 13 of 27 Rev 1 21 2014 8 36 AM 8 30 PM 16 SA 1L Ge HEATING HUMIDITY Upon entering Scene mode this screen will display for 2 seconds COOLING 1 i LCD display if Up button is tapped i j HEATING gt HUMIDITY I m HUMIDITY LCD displays when using Up or Down buttons to select from among the 4 controller groups Remove INSTEON Wireless Thermostat as a Controller If you want to remove INSTEON Wireless Thermostat from a scene as a controller follow instructions below Whenever possible use software for managing scene memberships Note If you choose to remove INSTEON Wireless Thermostat from use it is important that you remove scene memberships from all responders Follow the instructions below for each responder of which INSTEON Wireless Thermostat is a member 1 Press and hold INSTEON Wireless Thermostat Set button until it beeps INSTEON Wireless Thermostat Set LED will blink green 2 Press and hold INSTEON Wireless Thermostat Set button again to put it in scene mode INSTEON Wireless Thermostat Set LED will blink red LCD display indicates the group from which you are removing the scene 3 Tap Up and Down arrows to select appropriate group to remove from e Group 1 Cooling mode ch
34. utton Temp Humidity Low Humidity Set 4 m Cal Moues 0 i Internal Temperature i Calibration High Humidity Set Mode Button M ode Button Temperature Format Mode Button BE Humidity Calibration 4 Mlode Button E External Temperature J Calibration External Temperature Mode Button Beep on Button Press Mode Button 7 Button Lock nE 4 Mode Button a Programming Lockout Oe Mode Button Activation Delay 5 Mode Button User Setup Mode 1 Press and hold Program button to access the following options INSTEON Page 16 of 27 Rev 1 21 2014 8 36 AM e Press Mode to step between menu items Sub mode number will appear on top of the screen Sub mode 01 Display LED on time select default is 10 seconds Sub mode 02 Humidity low setpoint default is 30 Sub mode 03 Humidity high setpoint default is 90 Sub mode 04 Temperature format select default is Fahrenheit Sub mode 05 Internal or External temperature sensor default is Internal Sub mode 06 Beep on button press default is off Sub mode 07 Button lock default is off Sub mode 08 Programming lock default is off Sub mode 09 Activation delay default is 5 minutes O O O O OOOHOO 2 Press the Up or Down arrow to change a setting e Sub mode 01 LED backlight ON time 10 second default a Tap up or Down arrow to step between OFF 10 seconds 60 seconds and ON N