Home

INSTEON 2486Dxxx User's Manual

image

Contents

1. Add Multiple Scene Responders formerly Multi Linking Mode 1 Tap Scene Controller button on KeypadLinc 2 Press and hold KeypadLinc s Set Button until it beeps KeypadLinc s Scene button LED will blink All illuminated LEDs on KeypadLinc will brighten to 100 3 Tap KeypadLinc s Set Button KeypadLinc s Scene button LED will continue blinking 4 For each Responder you are adding a Adjust Responder to desired Scene state for KeypadLincs you must tap the button at least once until in desired state b Press and hold Responder s Set button until it beeps or LED flashes KeypadLinc will Beep 5 After all Responders have been added tap KeypadLinc s Set Button KeypadLinc s Scene button LED will stop blinking KeypadLinc s LEDs will return to normal brightness 6 Test Scene by tapping Scene button a couple of times All the Responders added above will respond Remove Multiple Scene Responders formerly Multi Unlinking Mode 1 Tap Scene Controller button on KeypadLinc 2 Press and hold KeypadLinc s Set Button until it beeps KeypadLinc s Scene button LED will blink All illuminated LEDs on KeypadLinc will brighten to 100 3 Press and hold KeypadLinc s Set Button again until it beeps again KeypadLinc s Scene button LED will continue blinking 4 Tap KeypadLinc s Set Button KeypadLinc s Scene button LED will continue blinking 5 For each Responder you are removing a If aKeypadLinc button tap button b Press
2. Radio Button Groups by tapping each button in the group Each tap should turn On that specific button in the group and immediately turn Off any others in the group presently On Page 15 of 24 Rev 1 21 2014 7 36 AM Part 2 Radio Button Groups 1 Tap each radio group button until its LED is Off 4 Press and hold one at a time buttons B C and D until each beeps 2 Press and hold button A until it beeps about 10 sec Beep 10 sec Beep 10 sec Beep 10 seconds 5 Tap the button you started with in step 1 to end this programming step 10 sec Beep o Press and release 3 Tap the Set button this places the unit in Add Multiple Responders mode 6 Repeat steps 1 5 inserting button B into step 2 and all other buttons into step 4 7 Repeat steps 1 5 inserting button C into step 2 and all other buttons into step 4 8 Repeat steps 1 5 inserting button D into step 2 and all other buttons into step 4 9 After ending the last program step verify your Radio Button Groups by tapping each button in the group Each tap should turn On that specific button in the group and immediately turn Off any others in the group presently On Air Gap To remove all power from KeypadLinc and connected light s pull the Set button at the bottom of the switch out as far as it will go about 1 8 It might be helpful to use a small screwdriver This will open mechanical contacts cr
3. l h 2401L LED Color Ch Kit for LED Color Change Kit htt di smarthome com 2401L Color Chanae Kit for KeypadLinc 4 Color p aspx http www smarthome com KeypadLinc KeypadLinc Tabletop Contro ller 2vj 2wX nav aspx Blank Buttons Clear Buttons Table Top Stand Kit Specifications General Product Name KeypadLinc Dimmer INSTEON 6 8 Button Scene Control Keypad with Dimmer Manufacturer Product Number 2486D 6 button White 2486DWHE6 689076407847 Almond 2486DAL6 71812238731 1 Light Almond 2486DLAL6 813922011586 Black 2486DBK6 718122387519 Gray 2486DGY6 718122387915 Ivory 2486DIV6 718122388110 Brown 2486DBR6 718122387717 8 button White 2486DW H8 689076409049 Almond 2486DAL8 718122387410 Light Almond 2486DLAL8 813922011593 Black 2486DBK8 718122387618 Gray 2486DGY8 718122388011 Ivory 2486DIV8 718122388219 Brown 2486DBR8 718122387816 6 and 8 button Responder Scenes Page 19 of 24 Rev 1 21 2014 7 36 AM Brightness Levels 32 256 with software Local On Level Adjustable 32 levels plus Resume Dim Adjustable 0 1 seconds to 8 seconds locally 0 1 seconds to 9 Local Ramp Rate minutes via software Off Fast Off Press and Hold Dim Off Fast Off Incremental Dim Scene Commands Supported as Controller Fast On Press and Hold Bright Fast On Incremental Bright Press and Hold Bright Yes Always 150 Open air Scene Commands Supported a
4. KeypadLinc button LED will toggle between On and Off Load if main Scene Remove KeypadLinc from a Scene as a Responder If you want to remove KeypadLinc from a Scene s as a Responder follow instructions below Whenever possible use software such as HouseLinc for managing Scene memberships Note If you choose to remove KeypadLinc from use it is important that you remove Scene memberships from all Controllers Otherwise Controllers will retry commands repetitively creating network delays Follow the instructions below for each Scene Controller that KeypadLinc is a member of Press and hold Controller s Scene button until Controller beeps Controller s LED will blink 2 Press and hold the Scene button until Controller beeps again Controller s LED will continue blinking Tap KeypadLinc button to remove from Scene 4 Press and hold Set button on KeypadLinc until it double beeps KeypadLinc s LED will flash once Controller s LED stops blinking 5 Confirm Scene removal was successful by tapping the button on the Controller with Scene you just removed k KeypadLinc will no longer respond Changing Button Modes Toggle Non Toggle Mode You can change any button to any one of 3 Button Modes software is recommended e Toggle toggles between ON and OFF commands each time it is tapped e Always Off sends OFF every time it is tapped e Always On sends ON every time it is tapped Note You cannot change the dedica
5. Button Configuration neresen an a a a A a 17 ChanomMo BUION Sesu a A 18 Local Ramp Rate software recommended cccccecccseseeceeeeaeeeeeceeseeeseceeesaeaeeeeeeseaaeeeeessaaeeeeeessaaeeeees 18 Additional RESOUICE Sucina iaa 18 PICHON VIDEOS sieaa a a a a O a node dutch E A 18 Optional ACCES OM E a a A a E 19 SPECINCINO NS iaa a se uancevevonssy cues sassasuueseususesaecssunamewuseenieocents 19 TrouUDIESNOOUNG ia 21 certitication and Warrants 24 CORIO AU Ni e da 24 FCC and Industry Canada Compliance StateMent oooccccnnccccccconnccnnnnccnonononnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnons 24 ETC UL Warning Sade Ward aus i 24 LINEO Wa at cios 24 A E a de a eco ee sen eos r aoeule eee eee 24 Page 2 of 24 Rev 1 21 2014 7 36 AM KeypadLinc Features and Benefits Congratulations on purchasing the elegant high quality KeypadLinc INSTEON X10 scene controller This intuitive keypad controls up to 6 8 scenes and has a built in dimmer to create dramatic whole room changes at the tap of a button Additionally each button has an LED backlight that can be easily configured as a status indicator for virtually any INSTEON device scene you wish to monitor Features Easy to set up and use Integrated dimmer up to 600 watts 932 dim levels and ramp rates Each button can be a scene controller and or responder Each button can control the other buttons on the keypad Supports up to 417 scene memberships Multipl
6. White wire from only has two wires wire in order to operate KeypadLinc to Neutral Pull a Neutral from nearby junction box KeypadLinc and the Make sure at least 2 dual band INSTEON Controller are on opposite products are properly installed to bridge the power line phases two power line phases Power line signals can t travel through some power filters Plugging the Controller directly receiving signals from Plug other modules into a FilterLinc or move INSTEON or X10 the other modules or the Controller to another Controllers outlet The Controller is plugged into a power strip Other modules are loading down the signal Add new or move existing INSTEON devices and retest INSTEON devices act as INSTEON network repeaters Install a power line signal blocker in your home Another Controller a timer or to keep X10 signals from neighboring homes sold ri Wilglefclice from interfering Consider not using The light turned on by yp KeypadLinc in X10 mode itself KeypadLinc may have an undesired Responder membership Use software to remove membership or perform a factory reset Page 21 of 24 Rev 1 21 2014 7 36 AM The controlled light does not appear to turn on or off right away Responder s Scene ramp Set a faster Ramp Rate software rate might be quite slow recommended Install a power line noise filter between the OL Load and KeypadLinc KeypadLinc is producing spell es peno le electrical noise that is
7. button LED will continue blinking 4 Press and hold Responder s Set button until it double beeps or LED blinks KeypadLinc will Beep Beep and its Scene button LED will stop blinking 5 Confirm that Scene removal was successful by tapping Scene button on and off Responder will not respond 1 If the Responder is a multi Scene device such as a KeypadLinc tap the Scene button you wish to control until its LED is in the desired Scene state on or off 2 If either the KeypadLinc or Responders LED continues to blink the addition failed Tap the device s Set button until LED stops blinking and try again Page 10 of 24 Rev 1 21 2014 7 36 AM 6 If you wish to remove multiple Responders from KeypadLinc repeat steps 1 5 for each additional Responder or see Remove Multiple Responders from a Scene Add KeypadLinc Button to a Scene as a Responder 1 Press and hold the Scene Controller button until it beeps Controller s LED will blink Tap KeypadLinc button you wish to be a Responder of the Scene at least once 3 Tap button again if necessary to get button s LED to desired state for Scene press and hold if adding the main Scene at a dimmed level 4 Press and hold KeypadLinc s Set button until it double beeps KeypadLinc s Scene button LED will flash once and return to previous state Controller s LED will stop blinking and it will Beep Beep 5 Confirm that Scene addition was successful by tapping on then off on the Controller s Scene button
8. dealer or an experienced radio TV technician WARNING Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ETL UL Warning Safety Warning CAUTION To reduce the risk of overheating and possible damage to other equipment do not install this device to control a receptacle a motor operated appliance a fluorescent lighting fixture or a transformer supplied appliance Gradateurs commandant une lampe a filament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente ou un appareil alimente par un transformateur Limited Warranty Seller warrants to the original consumer purchaser of this product that for a period of two years from the date of purchase this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner s Manual This warranty shall not apply to defects or errors caused by misuse or neglect If the product is found to be defective in material or workmanship or if the product does not perform as warranted above during the warranty period Seller will either repair it replace it or refund the purchase price at its option upon receipt of the product at the address below postage prepaid with pr
9. is not designed or approved for use on power lines other than 120V 60Hz single phase Attempting to use this product on non approved power lines may have hazardous consequences Recommended installation practices Use only indoors or in outdoor rated box Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing this product into Installing this product with the power on will expose you to dangerous voltages Connect using only copper or copper clad wire This product may feel warm during operation The amount of heat generated is within approved limits and poses no hazards To minimize heat buildup ensure the area surrounding the rear of this product is as clear of clutter as possible Each INSTEON product is assigned a unique INSTEON ID which is printed on the product s label To reduce the risk of overheating and possible damage to other equipment do not use this product to control Loads in excess of the specified maximum s or install in locations with electricity specifications which are outside of the product s specifications If this device supports dimming please note that dimming an inductive Load such as a fan or transformer could cause damage to the dimmer the load bearing device or both If the manufacturer of the load device does not recommend dimming use a non dimming INSTEON on off switch USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD Identifying the Electr
10. or Ground screw in wall box 13 Connect White Neutral wire from KeypadLinc to Neutral wire s in wall box usually White 14 Cap Red wire from KeypadLinc 15 Connect Black wire from KeypadLinc to same color Traveler from box 1 that you connected to Line along with same color Traveler wires leading to box 3 16 Cap the last unused Traveler wire s In Box 3 Load box 17 Connect bare Ground wire from KeypadLinc to bare Ground wire Box 2 4 way Red Traveler Wires Not Used Red Traveler Wires Not Used Ground Usually Copper or Groen Electrical Box Where Load Wires Leave Circuit Box 3 3 way or Ground screw in wall box 18 Connect White Neutral wire from KeypadLinc to Neutral wires s in wall box usually White 19 Connect Red wire from KeypadLinc to Load wire usually Black 20 Connect Black wire from KeypadLinc to Line Traveler from box 2 Line Traveled from box 1 through 2 into 3 usually Black 21 Cap unused Traveler wire 22 With button labels right side up gently place KeypadLincs into wall boxes and screw in place 23 Turn power back On KeypadLinc s On button and connected light will turn on Only KeypadLinc in box 3 will operate the load until you synchronize Scenes on the 3 devices 24 Add each KeypaoLincs to a Scene as a Controller and Responder of each other see Synchronized Scenes 22 Verify all KeypadLincs are working properly by tapping On and Off on a 6 button Keypad
11. outage Upon power being restored KeypadLinc will return its connected load and all LEDs to their states prior to power outage Add X10 Address to a Button 1 Tap the KeypadLinc button 2 Press and hold KeypadLinc s Set button until it beeps The button s LED will begin blinking 3 Send the desired X10 Address plus ON 3 times e g send B5 BON B5 BON B5 BON KeypadLinc will double beep and the button s LED will stop blinking Remove X10 Address from a Button If you are no longer going to utilize an X10 address associated with KeypadLinc it is very important that you remove its X10 address Otherwise KeypadLinc will still listen for X10 commands Somewhat hindering INSTEON reception and may respond to spurious X10 noise which is unavoidable Furthermore KeypadLinc will transmit an X10 address and command every time the button is tapped 1 Tap KeypadLinc button 2 Press and hold KeypadLinc s Set button until it beeps Button s LED will blink 3 Press and hold KeypadLinc s Set button again until it beeps again button s LED will continue blinking 4 Send the X10 Address plus ON 3 times e g send B5 BON B5 BON B5 BON KeypadLinc will double beep and button s LED will stop blinking Advanced X10 Programming Instructions on setting X10 primary address and Scene addresses can be found online http www smarthome com insteon x10 programming html Page 12 of 24 Rev 1 21 2014 7 36 AM Advanced Features
12. resulting from possession or use of this device including without limitation damage to property and to the extent permitted by law personal injury even if Seller knew or should have known of the possibility of such damages Some states do not allow limitations on how long an implied warranty lasts and or the exclusion or limitation of damages in which case the above limitations and or exclusions may not apply to you You may also have other legal rights that may vary from state to state U S Patent No 7 345 998 International patents pending Copyright 2012 Smarthome 16542 Millikan Ave Irvine CA 92606 800 762 7845 www smarthome com Page 24 of 24 Rev 1 21 2014 7 36 AM
13. tabs and snapping into place Gently pull the Set button out as far as it will go Wait 10 seconds While simultaneously holding the On Off upper left most button and the H button carefully press the Set button back in flush with the trim frame Once the Set button is pushed in continue holding the On Off button and H buttons for 3 seconds and then release KeypadLinc will Beep KeypadLinc is now in 8 Button Mode Page 17 of 24 Rev 1 21 2014 7 36 AM Changing Buttons KeypadLinc buttons can be changed to customize its appearance Use care when removing the keycaps Using a small flat edged screwdriver ONLY pry up on the sides of the keys from the middle of the keypad when possible Make sure you are centered on the key as to catch the small edge located there for this purpose de 4 A ak Also please note that behind the buttons are clear plastic filler pieces which diffuse the LED s light more elegantly Use care to keep these filler pieces in the button frame as you re assemble Should any damage occur to KeypadLinc during customization please contact 800 762 7845 and we will be happy to replace your frame Local Ramp Rate software recommended The Local Ramp Rate is the time it takes for the light s physically wired to KeypadLinc to brighten from Off to 100 brightness The default is 0 5 seconds Local Ramp Rate is adjustable from 0 1 seconds to 8 minutes 0 1 9 seconds using the instructions below or up to 8 minu
14. 9 With button labels right side up gently place KeypadLinc into wall box and screw into place commonly white 10 Turn on power light fan etc KeypadLinc s ON button and connected light will turn on Black Line 11 Verify KeypadLinc is working properly by tapping 120V to Ground ON and OFF on a 6 button KeypadLinc or MAIN On Off on a 8 button KeypadLinc KeypadLinc s button LED and connected load will turn on and off 12 Reinstall the wallplate Wiring Diagram Home s wire colors may vary Usually black red or blue Py i ar Usually Copper or Green 1 If the wires cannot be detached by unscrewing them cut the wires where they enter the switch then strip 12 of insulation off the ends Page 5 of 24 Rev 1 21 2014 7 36 AM Installation Circuit with 2 Switches Circuits with 2 switches are called 3 way circuits Both switches in a 3 way circuit need to be replaced by KeypadLincs and or SwitchLincs Note 3 way circuits require a pair of wires called Travelers between joining wall boxes to operate INSTEON switches dimmers and keypads do not require both Traveler wires for 3 way circuits to function Simply wire one to Line Neutral and Load the other s to Line and Neutral Use one Traveler to share Line between boxes Adding to a Scene creates a virtual 3 way circuit eo 6 Turn off circuit breaker s and or remove fuse s feeding wall boxes verify that power is off Pull both switch
15. KeypadLinc Dimmer INSTEON 6 and 8 Button Scene Control Keypad with Dimmer Owner s Manual Rev 5 0 2486Dxxx MASTER OUTSIDE BEDROOM LIGHTS KITCHEN STAIRS LIVING ENTRY ROOM i ALL ON ALL OFF e a A 8 button KeypadLinc Page 1 of 24 CEILING ON LIVING DINING ROOM ROOM ENTRY KITCHEN CEILING OFF 6 button KeypadLinc KeypadLinc Features and Benefits igors aina iii 3 A A E A dreamer ended 3 o A A ee 3 INSTallIng KeyDadLINC epicena E a a aA E aa aaa Eaa Ea 4 Identifying the Electrical Wires in your HOMEC cccccecccccseeeeeceeseeeceeeeeesaeeeessaeeessaaeeeeseaeeeesseneeessanseessaess 4 ho ouaa aa a a a a ad att at ts 4 Buton NAMING rada 4 Installation Circuit wih 1 SWIG A E E 5 Installation Circuit with 2 SWITCHES iia 6 Installation Circuit with 3 Or more Switches ccccccoconncnnccccnonconccononncnnnnononnnnnnnnnnnncnnnnononnnnnnnonnnrnnnnonnnanoss 7 USING KE VD aGline venir ida 9 en teeta alka cate ated ieee nati Lie rateead ss 9 E o a acs callia naa a 9 Button Tap Press and Holds a aa 9 OCEAN OMSL SVS I iss okie teed ut aan icc leutien ect aclu anee isc icd 9 Setting UD INSTEON SCENES aca iia cala 10 Add KeypadLinc Button to a Scene as a Controller ooonccnccccconccnncncnonnnnnononancnnnnnnnanennnnonnnncnnnnnnnas 10 Remove KeypadLinc Button from a Scene as a Controller oooonncnncconnnccnncconnnccnncnonnnncnnenon
16. Linc in 8 Button Configuration Simultaneously tap the D and E buttons KeypadLinc will beep Keypad s Beeper will toggle to on if was off or off if it was on Page 14 of 24 Rev 1 21 2014 7 36 AM Radio Button Groups only 1 LED of N at a time software recommended This feature is especially handy if you have multiple Scenes controlling the same devices such as Lights Bright Lights Medium and Lights Off When you tap any of the Scene buttons the others LEDs will turn off as if they were Scene Responders perfect for Scene change indication This is a two part programming sequence as follows Part 1 Radio Button Groups 1 Tap each radio group button one at a time 4 Press and hold one at a time buttons B C each LED is on In this example we will group and D until each beeps the four small buttons on 6 button KeypadLinc los Beep loas Beep Dies Beep 2 Press and hold button A until it beeps about 5 Tap the button you started with in step 1 to 10 seconds end this programming step l E Beep l Press and release 3 Tap the Set button this places the unit in Add 6 Repeat steps 1 5 inserting button B into step Multiple Responders mode 2 and all other buttons into step 4 7 Repeat steps 1 5 inserting button C into step 2 and all other buttons into step 4 8 Repeat steps 1 5 inserting button D into step 2 and all other buttons into step 4 9 After ending the last program step verify you re
17. Linc or MAIN On and Off on an 8 button KeypadLinc turning connected light on and off 25 Reinstall wallplates Red Traveler Wires Not Used 1 lf Neutral is not available in this box use other unused Traveler from box 1 to carry Neutral to box 2 Label and mark any differently colored wire being connected to Neutral with a piece of white tape to flag it as Neutral Page 8 of 24 Rev 1 21 2014 7 36 AM Using KeypadLinc LEDs LED Meaning Off Brighter Button Taps before Tap Notes 1 The connected light s will react just like Scene Responders to button taps of MAIN when using an 8 button KeypadLinc and On or Off when using a 6 button KeypadLinc 2 LED will mimic the on off status of a dimmer whose Scene level is 100 bright 3 ON button on a 6 button KeypadLinc is an Always On button while OFF button is an Always Off button Other buttons are toggle by default Button Tap Press and Holds Button LED Effect of First Button Type before Tap Press and Hold Effect of Subsequent Press and Holds i i Opposite of last Press and Hold Toggle Of Brighten Scene until j aaa release e g if last was brightening it will dim i i Opposite of last Press and Hold Teale On Dim Scene until i ae release e g if last was brightening it will dim Always On Brighten Scene until release Always Off Dim Scene until release Local On Level The Local On Level is the brightness that the light s physical
18. anccanononnns 10 Add KeypadLinc Button to a Scene as a Responder oooocccnncccnncccnncccnoncnnncnonancnonononancnnnnonnnnrnnnnonnnnennnnnnnn 11 Remove KeypadLinc from a Scene as a Responder c oooccccnncccccnccnnccononnconcnononncnnnnonnnncnnnnnnnnnrnnononnnnranennnnns 11 Changing Button Modes Toggle Non Toggle Mode ccccocoonccncccnoocccnncncnonccnncnnnncccnnononancnncnnnnanconnnos 11 EP BION SS stand dei iio 12 POWER RESIO O siata A tidia 12 AJA ATA toa A S 12 Remove X10 Address from a BUON nae a a a a a a 12 Advanced AMO PEOR oe dis de 12 Advanced FeattresS ii la 13 Add Multiple Scene Responders formerly Multi Linking Mode oooccncccccoccnncccccoccnnnoncnancnnccononncnnnnonnno 13 Remove Multiple Scene Responders formerly Multi Unlinking Mode oocccccccnccnccconcnncccncnnnocanonoss 13 Synchronized Scenes formerly Cross Linking ccccccoconncnncccnonccnncnononcnnnnnononcnnnononancnnnonnnanrnnnnonnanennnoss 13 Beep 0n Button Tap OF PES SS urraca 14 Radio Button Groups only 1 LED of N at a time software recoMMendedO coooocccncccnnncccncconnnnconnnos 15 A aare eS biesiarinee oll apex Pa esecee ged veal tuiecumstudanea Dini eae Null na uiined Auli ea a 16 Faclory ICS CL ROPERO eo O O Ia IU RE A 16 Changing Between 6 and 8 Button Configurations cooocccnncccconncnncnnnonnnonononancnnnonnnancnnnnnonancnnnnnnnnnennnoss 17 Changing 10 6 Button Connqurauon iii ce ee 17 Changing to 8
19. and hold Responder s Set button until it beeps or LED flashes 6 After all Responders have been removed Tap KeypadLinc s Set Button KeypadLinc s Scene button s LED will stop blinking KeypadLinc s LEDs will return to normal brightness 7 Test Scene by tapping Scene button a couple of times All the Responders removed will not respond Synchronized Scenes formerly Cross Linking Synchronized Scenes are Scenes where all members stay synchronized Common examples include 3 way lighting circuits and Scenes with a single Load bearing device For our example we will Synchronize Scenes on 2 SwitchLincs and identify them as A and B Example 2 Switch Circuit 1 Turn both switches dimmers on to the desired and same Scene level 2 Press and hold Switch A s Set button until it beeps or LED blinks Switch A s LED will blink 3 Press and hold Switch B s Set button until it double beeps or LED flashes Switch B will Beep Beep and ts LED will flash once Switch A will Beep Beep and its LED will stop blinking 4 Press and hold Switch B s Set button until it beeps or LED blinks Switch B s LED will blink 5 Press and hold Switch A s Set button until it double beeps or LED flashes Switch A will Beep Beep and its LED will flash once Page 13 of 24 Rev 1 21 2014 7 36 AM Switch B will Beep Beep and its LED will stop blinking 6 Test the group by controlling the Load from Switch A and then Switch B The L
20. at may cause undesired operation of the device Le present appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorise aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radiolectrique subi mme si le brouillage est susceptible d en compromettre le fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio and television reception However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or relocate the receiving antenna of the device experiencing the interference Increase the distance between this device and the receiver Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver Consult the
21. c beeps KeypadLinc s Scene button LED will blink 3 Adjust Scene Responder to the state you want when Scene is activated from KeypadLinc e g 50 25 or even OFF 4 Press and hold Responder s Set button until it double beeps or until its LED Load flashes KeypadLinc will Beep Beep and ts LED will stop blinking Responder s LED will stop blinking and it may Beep Beep 5 Confirm that Scene addition was successful by tapping on off on the KeypadLinc Scene button The Responder will toggle between the Scene s on level and off 6 If you wish to add more Responders to the Scene repeat steps 1 5 for each additional Scene Responder or see Add Multiple Responders to a Scene Remove KeypadLinc Button from a Scene as a Controller If you want to remove KeypadLinc from a Scene s as a Controller follow instructions below Whenever possible use software such as HouseLinc for managing Scene memberships Note If you choose to remove KeypadLinc from use it is important that you remove Scene memberships from all Responders Otherwise delays and error blinks reports may result Follow the instructions below for each Responder that KeypadLinc is a member of 1 Tap KeypadLinc Scene button ON for 6 button main Scene The Responder s will respond 2 Press and hold KeypadLinc s Set button until it beeps KeypadLinc s Scene button LED will blink 3 Press and hold KeypadLinc s Set button until it beeps again KeypadLinc s Scene
22. e buttons can be included in the same scene Dual On Off settings toggle default and always send On Off Dimmable status LEDs Beeper makes setup a breeze and can function as a chime module Configurable to beep on each button tap or press X10 compatible Wires in like a standard wall switch requires a Neutral wire All settings preserved in non volatile memory through power failures Local programming lockout available via software 2 year warranty Custom etched buttons available Can be converted between 6 and 8 button modes 6 button KeypadLinc 8 button KeypadLinc Dedicated On Off scene button Po load controlling ON e Secondary scene 7 butt Secondary scene__ uttons buttons MS Dedicated On Off x gt scene buttons 3 load controllin a j Ae 9 Secondary scene wee buttons Set button push Air gap pull Set button push Air Gap Pull What s in the Box KeypadLinc Dimmer Quick Start Guide 2mounting screws 4wire nuts Page 3 of 24 Rev 1 21 2014 7 36 AM Installing KeypadLinc CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada Use indoors only This product
23. eating an Air Gap To restore power tap the air gap back into place until its top is even with the trim frame Factory Reset Factory Reset clears all user settings from KeypadLinc including INSTEON Scenes On Levels Ramp Rates X10 addresses etc 1 Pull Set button out creating an Air Gap 2 Wait 10 Seconds 3 Push Set Button in and Hold it in KeypadLinc will Beep Page 16 of 24 Rev 1 21 2014 7 36 AM 4 Release the Set button Device s embedded software will re write all settings to factory defaults A couple of seconds will pass KeypadLinc will Beep Beep LEDs will return to normal brightness KeypadLinc returns to Ready Mode Connected load will turn on Changing Between 6 and 8 Button Configurations Changing to 6 Button Configuration 1 2 3 4 9 Replace the 8 button plate with the 6 button plate Attach the change out plate to the switch body by aligning the tabs and snapping into place Gently pull the Set button out as far as it will go Wait 10 seconds While simultaneously holding the On and Off buttons carefully push the Set button back in flush with the trim frame Once the Set button is pushed in continue holding the On and Off buttons for 3 seconds and then release KeypadLinc will Beep KeypadLinc is now in 6 Button Mode Changing to 8 Button Configuration 1 2 3 4 9 Replace the 6 button plate with the 8 button plate Attach the change out plate to the switch body by aligning the
24. er Wires Not Used Electrical Box Where Load Wires Leave Circuit Box 2 3 way Red Traveler Wires Not Used y r Ground Copper Rev 1 21 2014 7 36 AM 16 Cap unused Traveler wire 17 With button labels right side up gently place KeypadLincs into wall boxes and screw in place 18 Turn power back on KeypadLinc s On button and connected light will turn on Only KeypadLinc in box 2 will operate the Load until you synchronize Scenes to the 2 devices 19 Add both KeypadLincs to a Scene as a Controller and Responder of each other see Synchronized Scenes 20 Verify both KeypadLincs are working properly by tapping On and Off on a 6 button KeypadLinc or MAIN On and Off on an 8 button KeypadLinc turning connected light on and off 21 Reinstall wallplates Installation Circuit with 3 or more Switches Circuits with 3 or more switches are called 3 way 4 way circuits All switches in 3 way 4 way circuits need to be replaced by KeypadLincs and or SwitchLincs Note 3 way 4 way circuits require a pair of wires called Travelers between joining wall boxes to operate INSTEON switches dimmers and keypads do not require both Traveler wires for 3 way 4 way circuits to function Simply wire one to Line Neutral and Load the other s to Line and Neutral Use one Traveler to share Line between boxes Adding to a Scene creates a virtual 3 way 4 way circuit The following example shows three switches 1 Turn off circuit breaker s and or remove
25. errupter jhe AFCI Murray 2 Pole Combination Type Arc Fault Circuit Interrupter MP215AFCP Install power line noise filter between the output and the Load There might be loose connections within your home s wiring Consult an electrician to check the wiring in your home KeypadLinc still controls devices even after factory reset Scene memberships exist in the Responder Remove Responder from KeypadLinc Button If you have tried these solutions reviewed this Owner s Manual and still cannot resolve an issue you are having with KeypadLinc please call 800 762 7845 Page 23 of 24 Rev 1 21 2014 7 36 AM Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO a nationally recognized independent third party testing laboratory The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U S and Canadian device safety standards that the manufacturing site has been audited and that the manufacturer has agreed to a program of quarterly factory follow up inspections to verify continued conformance FCC and Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and Industry Canada RSS 210 Rev 7 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference including interference th
26. es from their wall boxes each existing 3 way switch will have no less than 3 wires Remove wires from existing switches Make sure wires are safely separated from each other and turn power back on Using a voltage meter measure each wire to Ground in both boxes until you find the single wire supplying 120V Line a We will now refer to that location as box 1 b The other box will have the Load wire That will be box 2 Turn power back off In Box 1 Line box 1 8 9 Connect bare Ground wire from the KeypadLinc to bare Ground wire or Ground screw in wall box Connect White Neutral wire from KeypadLinc to Neutral wire s in wall box usually White Using a wire nut cap Red wire from KeypadLinc 10 Connect Black wire from KeypadLinc to 120V Line wire in wall box usually Black along with one Traveler wire running between boxes preferably Black Note color of Traveler you are using as this will carry Line voltage to box 2 11 Cap unused Traveler In Box 2 Load box 12 Connect bare Ground wire from KeypadLinc to bare Ground wire or Ground screw in wall box 13 Connect White Neutral wire from KeypadLinc to Neutral wire s in wall box usually White 14 Connect Red wire from KeypadLinc to Load wire 15 Connect Black wire from Page 6 of 24 KeypadLinc to same color Traveler from box 1 carrying Line usually Black Enters Circuit Box 1 3 way U Elecirical Box Where Power Red Travel
27. fuse s feeding wall boxes verify that power is off 2 Pull all three switches from their wall boxes each existing 3 way switch will have a minimum 3 wires 4 way switches will have 4 wires 3 Remove wires from existing switches 4 Make sure wires are safely separated from each other and turn power back on 5 Using a voltage meter measure each wire to Ground in all three boxes until you find the single wire supplying 120V Line a We will now refer to that location as box 1 b The location having 2 sets of matching pairs of wires will be box 2 i e 2 Reds and 2 Blacks or other matching colors These are 2 Travelers from box 1 and 2 Travelers leading to box 3 c The last box will have the Load wire that will be box 3 6 Turn power back off In Box 1 Line box 7 Connect bare Ground wire from es Electrical Box Where Power KeypadLinc to bare Ground wire or lih Ground screw in wall box 8 Connect White Neutral wire from KeypadLinc to Neutral wire s in wall box usually White 9 Cap Red wire from KeypadLinc 10 Connect Black wire from KeypadLinc to 120V Line wire in wall box usually Black along with one Traveler wire running between boxes preferably Black Note color of Traveler you are using as this will carry Line voltage to box 2 11 Cap unused Traveler wire Red Traveler Wires Not Used Page 7 of 24 Rev 1 21 2014 7 36 AM In Box 2 Traveler box 12 Connect bare Ground wire from KeypadLinc to bare Ground wire
28. ical Wires in your Home Line usually Black may also be called HOT LIVE or Power carries 120VAC electricity into the wall box Neutral usually White commonly daisy chained from box to box usually appearing as a White wire bundle Load usually Black from a separate cable jacket Ground Bare wire or metal fixture if grounded IMPORTANT If you have any difficulties or questions consult an electrician If you are not knowledgeable about and comfortable with electrical circuitry you should have a qualified electrician install the product for you Tools Needed e Flathead screwdriver e Phillips screwdriver e Wire cutter stripper e Voltage meter Button Naming Throughout this manual we will use the following naming conventions 6 Button 8 Button MAIN On Of EEL DOC E Page 4 of 24 Rev 1 21 2014 7 36 AM Installation Circuit with 1 Switch 1 At electrical panel turn off circuit breaker s and or remove fuse s feeding wall box Verify that the power is off before continuing 2 Remove wallplate from the switch Unscrew switch and gently pull out 3 Disconnect wires from switch 4 Turn on power 5 Use a voltage meter to identify the Line and Load wires connected to the switch 6 Identify Neutral and Ground wires A 7 Turn off power commonly bare 8 Connect wires as per table diagram confirm firm pare Opper copper green wire or attachment with no exposed wire
29. ly wired to KeypadLinc will come on at when turned on locally The default is 100 Local On Level can be set to any one of 33 settings 32 fixed brightness levels 8 to 100 Or Resume Bright e Previous brightness level is stored when turned off and recalled to that level brightness when turned back on Page 9 of 24 Rev 1 21 2014 7 36 AM To set KeypadLinc s Local On Level 1 Press and hold On and or Off or Main in 8 button configuration until the connected light is at the brightness desired when turned on locally turn the light off if you wish to use the Resume Bright feature 2 Tap KeypadLinc s Set button KeypadLinc will Beep 3 Test the Local On Level settings by tapping the On Off or Main Setting Up INSTEON Scenes INSTEON remote control is done using Scenes Scenes allow you to instantly recall favorite lighting and appliance settings at the touch of a button or in response to central control or even a sensor Each Scene has at least one Controller and at least one Responder Simple Scenes can be setup using the instructions below Software is recommended for setup of larger scenes Add KeypadLinc Button to a Scene as a Controller Follow the steps below to control a Scene one or more INSTEON devices from a KeypadLinc button 1 Tap KeypadLinc button of choice use button labeled ON when using a 6 button Keypads as main Scene 2 Press and hold KeypadLinc s Set button until KeypadLin
30. oad Switch A s status LED s and Switch B s status LED s will all remain in synch Example Synchronized Scene with numerous members Software is recommended however the following steps when carefully followed will also work For our example we will Synchronize SwitchLincs 1 through N where N any number 1 Turn all switches on to the desired and same Scene level a Press and hold Switch 1 s Set button until it beeps or LED blinks Switch 1 s LED will blink b Tap Switch 1 s Set button Switch 1 s LED will continue blinking it is now the Scene Controller c For Switches 2 through N press and hold the Set button on each one at a time until it double beeps or LED flashes Switch 2 through N will Beep Beep and its LED will flash once d Tap Switch 1 s Set button Switches 2 through N are now Responders and Synchronized to Switch 1 2 Return to Step 1 above systematically placing each of the remaining switches 2 N into this step as the Scene Controller and all others as Responders of the Scene All switches 1 N are now synchronized as Scene Controllers and Scene Responders of all group members Beep on Button Tap or Press Buttons can be set to Beep Mode so KeypadLinc will beep every time a button is used Default Off If KeypadLinc in 6 Button Configuration Simultaneously tap the B and C buttons KeypadLinc will beep Keypad s Beeper will toggle to on if was off or off if it was on If Keypad
31. on commands but not off hth o l a ae Interfering with the Install additional INSTEON devices to boost KeypadLinc reception of the INSTEON signal power line signal My light only turns off when I tap a button on The On Level may be setto Set a brighter On Level See Setting the On KeypadLinc but can fully off or very dim Level brighten and dim it KeypadLinc may be set up Remove the X10 address When try to turn on my with an INSTEON On Level light with another at a high brightness and an Controller the light turns X10 Primary or Scene Remove the X10 address from the INSTEON on then back off address On Level at a low Controller brightness When I tap a button on If the INSTEON device is still available KeypadLinc it takes a KeypadLinc is trying to remove it from KeypadLinc or repower it long time for other control a Scene Responder INSTEON devices it is that is not powered on Perform a factory reset controlling to respond KeypadLinc doesn t respond to X10 address A1 when first set it up I m having difficulty The X10 MNOP house and Don hold down the buttons on your X10 performing advanced X10 unit codes were sent in the Controller too long to avoid duplicate codes programming wrong order being sent KeypadLinc ships without an X10 Address Add an X10 address to desired button The bulb filaments are vibrating Use rough The dimming component service 130 volt or appliance grade bulbs to The Load is buz
32. oof of the date of purchase and an explanation of the defect or error The repair replacement or refund that is provided for above shall be the full extent of Seller s liability with respect to this product For repair or replacement during the warranty period call the INSTEON Gold Support Line at 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to Smarthome ATTN Receiving 16542 Millikan Ave Irvine CA 92606 5027 Limitations The above warranty is in lieu of and Seller disclaims all other warranties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the above warranty and disclaimer Home automation devices have the risk of failure to operate incorrect operation or electrical or mechanical tampering For optimal use manually verify the device state Any home automation device should be viewed as a convenience but not as a sole method for controlling your home In no event shall Seller be liable for special incidental consequential or other damages
33. s Responder Press and Hold Dim gt software Configurable RF Range X10 Support X10 Addresses INSTEON Device Category 256 max unassigned by default D 0x01 Dimmable Lighting Control 2486Dxx8 2486Dxx6 0x1C INSTEON Device Subcategory Ox1B X Mechanical Mounting Standard single gang wall box Wires 4 16 gauge Black Line White Neutral Red Load Bare Ground Wires Case Color Clear Set Button Plastic UV Stabilized Polycarbonate lt D ep Beeper LED 8 White Dimensions 4 1 H x 1 8 W x 1 2 D Weight 3 6 oz Operating Environment Indoors 32 104 F Operating Humidity Range 0 85 Relative Humidity Operating Temperature Range Electrical 120VAC 10 60Hz 600 Watts in a single gang box Voltage Frequency Maximum Dimmer Load Page 20 of 24 Rev 1 21 2014 7 36 AM a Troubleshooting Make sure the circuit breaker is turned on Make sure the air gap Set button is not pulled out The LEDs on KeypadLinc KeypadL inc is not getting Check junction box wires to ensure all are not turning on at all power connections are tight and no bare wires are and won t control my light exposed Check the light fixture to ensure all connections are tight and no bare wires are exposed Look in the rear of the junction box for a group of Neutral wires all tied together with a wire nut The switch I m replacing KeypadLinc needs a Neutral usually White Connect the
34. ted On and Off buttons when in 6 button configuration 1 Tap the button you want to change 2 Press and hold KeypadLinc s Set button until it beeps The button s LED will begin blinking All illuminated LEDs on KeypadLinc will brighten to 100 3 Press and hold KeypadLinc s Set button a 2 time until it beeps a 2 time The button s LED will continue blinking 4 Press and hold KeypadLinc s Set button a 3 time until it beeps a 3 time The button s LED will stop blinking 1 If the Controller does not have a beeper wait until its LED begins blinking Most models For devices without beepers hold until its LED begins blinking this may take 10 seconds Page 11 of 24 Rev 1 21 2014 7 36 AM The button rotates to the next Button Mode in the cycle Toggle gt Always Off Always Off gt Always On Always On gt Toggle 5 Tap the button several times to confirm it is now in the desired state a If you wish to rotate button mode again return to step 2 LED Brightness KeypadLinc s LEDs can be set to any one of 32 brightness levels 1 Simultaneously tap the buttons highlighted at right KeypadLinc will beep 2 Press and hold on and or off button s to brighten and or dim to desired brightness 3 Simultaneously tap the highlighted buttons again KeypadLinc will beep Back to ready mode Power Restore KeypadLinc stores all of its Scenes properties etc in non volatile memory As such all settings are retained after a power
35. tes using software such as HouseLinc 1 Adjust the connected light s to brightness corresponding to desired Ramp Rate Brightness Level Ramp Rate in Seconds tm 2 Double tap the Set button on your KeypadLinc KeypadLinc will Beep Beep 3 Test the Ramp Rate settings by tapping the On Off buttons on your KeypadLinc or Controller Connected light s will ramp up and down at the new rate 4 Start again if the ramp rate is not as desired or if your double tap was not fast enough you may have accidentally changed the Local On Level instead of the Local Ramp Rate note software allows you to set on levels and ramp rates exactly as desired and consistently around the house Additional Resources Find home automation solutions helpful tips interactive demos videos user forums and more at the Smarthome Learning Center www smarthome com learningcenter html Helpful Videos Changing KeypadLinc Buttons Adding LED Diffusers to the KeypadLinc Page 18 of 24 Rev 1 21 2014 7 36 AM Optional Accessories Accessories Custom Etched and Pre http www smarthome com ProductResults aspx Ntt custom 20etch Printed Buttons ed 20buttons Color and 6 8 Button http www smarthome com ProductResults aspx Ntt keypadlinc 20 Change Kits 15 button 20change 20kit http www smarthome com 2401BT10 Blank 10 Button Set for KeypadLinc White p aspx htto www smarthome com 2401CLB 6 or 8 Button Change Kit for KeypadLinc Clear p aspx
36. zing when inside KeypadLinc chops reduce the noise on or dim the power line sine wave to Run KeypadLinc in the full on mode or switch reduce the power to a non dimming KeypadLinc On Off relay Switch Pull the Set button on KeypadLinc all the way A surge or excessive noise OUt for 10 seconds to air gap it then tap back on the power line occurred In Perform a factory reset KeypadLinc will dissipate about 1 Watt per 100 Watts controlled Using metal junction boxes removing insulation around the outside of the box or controlling a smaller Load all will help lessen the heat KeypadLinc is locked up It is normal for wall dimmers KeypadLinc is getting to get warm KeypadLinc warm to the touch conforms to Safety standards KeypadLinc can turn off my Responder but Responder s Scene level is Add Responder to Scene again at desired nothing happens when Off Scene on level send an On Page 22 of 24 Rev 1 21 2014 7 36 AM Controller can turn off KeypadLinc KeypadLinc does respond to On KeypadLinc may be Added to Add KeypadLinc to Scene again at desired a Scene at its off state Scene on level Replace your AFCI with a less sensitive brand model Note Smarthome has conducted testing and has found that KeypadLinc modules do not trip when used with the following AFC models The AFCI might be too a KeypadLinc trips the Arc sensitive GE 15 Amp Combination Arc Fault ni Breaker THQL1115AFP2 Fault Circuit Int

Download Pdf Manuals

image

Related Search

Related Contents

Tecumseh AWG4517CXNXC Drawing Data  COMUNICADO 24-2013  Classification des méthodes d`évaluation du stress en entreprise  Trendnet TV-IP572WI surveillance camera  Professor Inácio Magalhães Filho  none 51006WS Installation Guide  スリーホールスタノト 取扱説明書 。フ繍  User`s Manual TemplateFullScreen software  RayBiotech, Inc. Quantibody Porcine Cytokine Array 3  Cables Direct UT-8216 patch panel  