1. board PCI Express slot 2 error LED PCI Express slot 1 error LED T T T Beg 1 ga DIMM 4 error LED DIMM 3 SAS SATA controller error LED L error LED DIMM 2 error LED GS E LED l Baseboard management 3 SAS SATA controller error LED er heartbeat Fan2 X je LED error LED DE Fan 1 U Nan o error LED Power good LED Fan 5 error LED Voltage Standby Fan 4 error LED regulator power LED error LED Table 3 System board LEDs LED Description Error LEDs component has failed Baseboard management controller heartbeat LED normally When one of these LEDs is lit it indicates that the associated This LED flashes to indicate that the mini BMC is functioning Standby power LED to ac power When this LED is lit it indicates that the server is connected IBM System x3250 M2 Types 4190 and 4194 User s Guide System board optional device connectors The following illustration shows the connectors for user installable optional devices Riser card connector DIMM 1 conne
2. Fan 3 connector Fan 2 connector Fan 1 connector IDE connector Microprocessor connector M Wake on LAN connector SATA 2 connector SATA 0 connector Power connector SAS SATA controller card connector Front USB connector Operator information panel connector Hot swap SAS SATA backplane power connector SAS signal connector some models Power connector Fan 5 connector Fan 4 connector Important Use only a supported IBM SAS SATA controller in the SAS SATA controller card connector For a list of supported optional devices for the server see http www ibm com servers eserver serverproven compat us Chapter 2 Installing optional devices 15 System board switches and jumpers The following illustration shows the switches and jumpers on the system board r1 T NT T EG IT A Boot block BB a recovery jumper mm ll ENO u T SAS SATA LL controller a ii a card e b d O 3 W Clear CMOS jumper The following illu
3. O NA A S O O O R A IE YE IT 00000 i OJ Systems management USB 3 connector Serial connector connector USB 4 connector Video connector Ethernet 2 connector Ethernet 1 connector You must turn off the server before you connect or disconnect cables See the documentation that comes with any external devices for additional cabling instructions It might be easier for you to route cables before you connect the devices to the server Cable identifiers are printed on the cables that come with the server and devices Use these identifiers to connect the cables to the correct connectors If the server comes with an installed operating system see the documentation that comes with the operating system for additional cabling instructions There is no keyboard connector or mouse connector on the server You can connect a USB keyboard and USB mouse to the server by using the USB connectors Updating the server configuration When you start the server for the first time after you add or remove an internal optional device or external SAS device you might receive a message that the configuration has changed The Configuration Setup Utility program starts automatically so that you can save the new configuration settings For more information see Chapter 3 Configuring the server on page 41 Some optional devices have device drivers that you must install For information about installing device drivers
4. SAS SATA backplane some models Air baffle SATA simple swap back panel some models Fans Power supply CD DVD interface card Operator information panel assembly CD DVD drive 3 5 inch hot swap hard disk drive some models 3 5 inch simple swap SATA hard disk drive some models Hot swap hard disk drive filler Simple swap SATA filler Copyright IBM Corp 2007 2008 13 14 2 5 inch models Riser card Assembly DIMM Heat exchanger assembly Heat exchanger retention module SAS SATA controller gt some models System board 2 5 inch hard disk drive backplane Power supply CD DVD interface card Operator information panel assembly CD DVD drive 2 5 inch 2 5 inch hard drive cage disk drive 2 5 inch filler panel IBM System x3250 M2 Types 4190 and 4194 User s Guide System board internal connectors The following illustration shows the internal connectors on the system board EI Wr E3 DIMM 2 Slot E3 DIMM 3 Slot E DIMM 4 Slot eS Bg NW IV SS fpem SAS SATA controller card ON ON
5. Server management Standby voltage for systems management features and monitoring IBM System x3250 M2 Types 4190 and 4194 User s Guide IBM Director System error logs Vital product data VPD includes information stored in nonvolatile memory for easier remote viewing Wake on LAN With IBM Director a network administrator can perform the following tasks View the hardware configuration of remote systems in detail Monitor the usage and performance of critical components such as microprocessors disks and memory Centrally manage individual or large groups of IBM and non IBM x86 based servers desktop computers workstations and notebook computers on a variety of platforms IBM Director provides a comprehensive entry level workgroup hardware manager It includes the following key features Advanced self management capabilities for maximum system availability Multiple operating system platform support including Microsoft Windows 2000 Server Windows Server 2003 Windows XP Professional AIX i5 OS Red Hat Linux SUSE Linux VMware and Novell NetWare For a complete list of operating systems that support IBM Director see the IBM Director Compatibility Document This document is in Portable Document Format PDF at http www ibm com systems management director resources It is updated every 6 to 8 weeks Support for IBM and non IBM servers desktop computers workstations and notebook computers S
6. on page 20 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables Remove the cover see Removing the cover on page 22 Attention To avoid breaking the retaining clips or damaging the DIMM connectors open and close the clips gently Open the retaining clip on each end of the DIMM connector Touch the static protective package that contains the DIMM to any unpainted metal surface on the server Then remove the DIMM from the package 5 Turn the DIMM so that the DIMM keys align correctly with the connector Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously The retaining clips snap into the locked position when the DIMM is firmly seated in the connector If there is a gap between the DIMM and the retaining clips the DIMM has not been correctly inserted open the retaining clips remove the DIMM and then reinsert it If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 38 Chapter 2 Installing optional devices 37 Po D Completing the installation To complete the installation complete the following steps 1 Reinstall the cover See Installing the cover for more information 2 Install the server in the rack cabinet See the Rack I
7. smbridge stop smbridge restart Note For more information about the SMBridge management utility program see Using the SMBridge management utility program on page 54 Using the baseboard management controller utility programs Use the baseboard management controller utility programs to configure the baseboard management controller download firmware updates and SDR FRU updates and remotely manage a network Using the baseboard management controller configuration utility program Use the baseboard management controller configuration utility program to view or change the baseboard management controller configuration settings You can also use the utility program to save the configuration to a file for use on multiple servers Go to http www ibm com systems support to download the utility program Run the utility program to create a configuration utility diskette Complete the following steps to start the baseboard management controller configuration utility program Chapter 3 Configuring the server 53 54 1 Insert the configuration utility diskette into the diskette drive and restart the server 2 From a command line prompt type bmc cfg and press Enter 3 Follow the instructions on the screen Using the baseboard management controller firmware update utility program Use the baseboard management controller firmware update utility program to download a baseboard management controller firmware update or a SDR FRU
8. ul iit 2 forl aS IBM System x3250 M2 Types 4190 and 4194 User s Guide Note Before using this information and the product it supports read the general information in Notices on page 57 and the Warranty and Support Information document on the IBM System x Documentation CD Second Edition March 2008 Copyright International Business Machines Corporation 2007 2008 All rights reserved US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp Contents Safety Chapter 1 The System x3250 M2 eee 4190 and 4194 Related documentation amp 4 Notices and statements in this document Features and specifications What your server offers Reliability availability and serviceability features IBM Director The Update Xpress program Server controls LEDs and power Front view Rear view Server power features Chapter 2 Installing optional devices Server components System board internal connectors System board switches and jumpers System board external connectors System board LEDs System board optional device connectors i Installation guidelines System reliability guidelines Working inside the server with the power on Handling static sensitive devices Removing the cover Installing an adapter Installing a Remote Supervisor Adapter Il SlimLine Installing a hard disk drive Installing a simple swap S
9. www ibm com ibm environment products index shtml Notice This mark applies only to countries within the European Union EU and Norway This appliance is labeled in accordance with European Directive 2002 96 EC concerning waste electrical and electronic equipment WEEE The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union This label is applied to various products to indicate that the product is not to be thrown away but rather reclaimed upon end of life per this Directive Appendix Notices 59 FE IOI Ik EU BHEBKLUVS JV 2r I 8b CO 2S FH S fuk OMAR ICIE EU s E LL T 5 BEER ET BERRE T7 2002 96 EC WEEE D 7 v AH vc WET COT EU HEIER IT 2 BE Hj Fas DEINE VL 7 VOTE FEED TW ET IDF NIE PARA RICH TIC GEO TIME 7 ME FT DVER HDI EE A SED TOILE DR MICH SW TVET Remarque Cette marque s applique uniquement aux pays de l Union Europ enne et la Norv ge L etiquette du systeme respecte la Directive europ enne 2002 96 EC en mati re de D chets des Equipements Electriques et Electroniques DEEE qui d termine les dispositions de retour et de recyclage applicables aux syst mes utilis s travers l Union europ enne Conform ment la directive ladite tiquette pr cise que le produit sur lequel elle est appos e ne doit pas tre jet mais tre r cup r en fin de vie
10. Adapter Il SlimLine the startup process will take several minutes longer than a typical startup 2 Earlier versions of the Remote Supervisor Adapter II SlimLine might not work in this server See http www ibm com servers eserver serverproven compat us for the supported Remote Supervisor Adapter II SlimLine versions To install a Remote Supervisor Adapter II SlimLine complete the following steps Chapter 2 Installing optional devices 27 28 Mounting bracket Remote Supervisor Adapter II SlimLine a SS a Semi oS UNSS SS SS SESS 5 Mounting bracket Mounting bracket retention latch Read the safety information that begins on page M and installation guidelines Turn off the server and peripheral devices and disconnect all power cords and external cables see Turning off the server on page 10 then remove the cover see Removing the cover on page 22 Power cable PCI X slot If the riser card assembly is an optional PCI X riser card assembly disconnect the riser card power cable from the riser card assembly Grasp the riser card assembly at the front and rear edges and lift to remove it from the server Place the riser card assembly on a flat static protective surface Put the protective plastic cover on the Remote Supervisor Adapter II SlimLine Turn the Remote Supervisor Adapter Il SlimLine so that the keys on the connector align correctly wit
11. BM Director CD IBM Enterprise X Architecture technology IBM X Architecture technology combines proven innovative IBM designs to make your x86 processor based server powerful scalable and reliable For more information see http www ibm com servers eserver xseries xarchitecture enterprise index html Large system memory capacity The server supports up to 8 GB of system memory The memory controller supports error correcting code ECC for up to four industry standard PC2 5300 667 MHz ECC double data rate DDR II unbuffered synchronous dynamic random access memory SDRAM dual inline memory modules DIMMs IBM ServerGuide Setup and Installation CD The ServerGuide Setup and Installation CD that comes with the server provides programs to help you set up the server and install a Windows operating system The ServerGuide program detects installed optional hardware devices and provides the correct configuration programs and device drivers For more information about the ServerGuide Setup and Installation CD see Using the Integrated network support The server comes with two integrated Broadcom Gigabit controllers which support connection to a 10 Mbps 100 Mbps or 1000 Mbps network For more information see Configuring the Gigabit Ethemet controllers on page 55 Large data storage capacity The server supports up to two 25 4 mm 1 inch slim high 3 5 inch hard disk drives Serial Advanced Technology Attachment SATA or seria
12. Documentation CD It contains information about the terms of the warranty and getting service and assistance Safety Information This document is in PDF on the IBM System x Documentation CD It contains translated caution and danger statements Each caution and danger statement that appears in the documentation has a number that you can use to locate the corresponding statement in your language in the Safety Information document Rack Installation Instructions This printed document contains instructions for installing the server in a rack e Problem Determination and Service Guide This document is in PDF on the IBM System x Documentation CD It contains information to help you solve problems yourself and it contains information for service technicians Depending on the server model additional documentation might be included on the IBM System x Documentation CD The System x and xSeries Tools Center is an online information center that contains information about tools for updating managing and deploying firmware Copyright IBM Corp 2007 2008 1 device drivers and operating systems The System x and xSeries Tools Center is at http publib boulder ibm com infocenter toolsctr v1 r0 index jsp The server might have features that are not described in the documentation that comes with the server The documentation might be updated occasionally to include information about those features or technical updates might be avai
13. In accordance with the European WEEE Directive electrical and electronic equipment EEE is to be collected separately and to be reused recycled or recovered at end of life Users of EEE with the WEEE marking per Annex IV of the WEEE Directive as shown above must not dispose of end of life EEE as unsorted municipal waste but use the collection framework available to customers for the return recycling and recovery of WEEE Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE For proper collection and treatment contact your local IBM representative Battery return program 60 This product may contain a sealed lead acid nickel cadmium nickel metal hydride lithium or lithium ion battery Consult your user manual or service manual for specific battery information The battery must be recycled or disposed of properly Recycling facilities may not be available in your area For information on disposal of batteries outside the United States go tolhttp www ibm com ibm environment products index shtml or contact your local waste disposal facility In the United States IBM has established a return process for reuse recycling or proper disposal of used IBM sealed lead acid nickel cadmium nickel metal hydride and battery packs from IBM equipment For information on proper disposal of these batteries contact IBM
14. Installing a hot swap hard disk drive The 3 5 inch drive hot swap server models support either two SAS 3 5 inch hard disk drives or two SATA 3 5 inch hard disk drives The 2 5 inch drive hot swap server models support four 2 5 inch SAS hard disk drives 2 5 inch drives 80 png eee GER H ZBE EERST E Emu s l c SU EEE E The installation procedure is the same for any of these drives The illustrations in this procedure show 3 5 inch SAS drives To install a hot swap hard disk drive complete the following steps Note If you have only one hard disk drive install it in the left or upper left drive bay Drive tray assembly Drive handle in open position Filler panel Attention To avoid damage to the hard disk drive connectors make sure that the cover is in place and fully closed whenever you install or remove a hard disk drive 1 Read the safety information that begins on page v and Installation guidelines on page 20 2 Make sure that the server cover is in place and fully closed 3 Remove the filler panel from the bay Attention To maintain proper system cooling do not operate the server for more than 10 minutes without either a drive or filler panel installed in each bay 4 Install the hard disk drive in the hot swap bay a Mak
15. These products are offered and warranted solely by third parties IBM makes no representations or warranties with respect to non IBM products Support if any for the non IBM products is provided by the third party not IBM Some software might differ from its retail version if available and might not include user manuals or all program functionality Product recycling and disposal This unit must be recycled or discarded according to applicable local and national regulations IBM encourages owners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed IBM offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products Information on IBM product recycling offerings can be found on IBM s Internet site at http Awww ibm com ibm environment products index shtml Esta unidad debe reciclarse o desecharse de acuerdo con lo establecido en la normativa nacional o local aplicable IBM recomienda a los propietarios de equipos de tecnolog a de la informaci n TI que reciclen responsablemente sus equipos cuando stos ya no les sean utiles IBM dispone de una serie de programas y servicios de devoluci n de productos en varios pa ses a fin de ayudar a los propietarios de equipos a reciclar sus productos de TI Se puede encontrar informaci n sobre las ofertas de reciclado de productos de IBM en el sitio web de IBM http
16. To clear the system event error log select Clear System Event Error Log and confirm the selection The system event error log is limited in size When the log is full new entries will not overwrite existing entries therefore you must periodically clear the system event error log When you are troubleshooting an error be sure to clear the system event error log so that you can find current errors more easily Chapter 3 Configuring the server 47 RSA II Event Error Log This choice is displayed only when a Remote Supervisor Adapter II SlimLine is installed in the server Select this choice to view the system error messages from the Remote Supervisor Adapter II SlimLine To clear the RSA II event error log select Clear RSA II Logs and confirm the selection The RSA II event error log is limited in size When the log is full new entries will overwrite the oldest entries When you are troubleshooting an error be sure to clear the RSA II event error log so that you can find current errors more easily Save Settings Select this choice to save the changes that you have made in the settings Restore Settings Select this choice to cancel the changes that you have made in the settings and restore the previous settings Load Default Settings Select this choice to cancel the changes that you have made in the settings and restore the factory settings Exit Setup Select this choice to exit from the Configuration Setup Ut
17. see the documentation that comes with each device If the server has a RAID configuration that uses the SAS SATA controller with integrated RAID hot swap SATA or SAS models only and you have installed or removed a hard disk drive you might have to reconfigure the disk arrays If the server has an optional RAID adapter and you have installed or removed a hard disk drive see the documentation that comes with the RAID adapter for information about reconfiguring the disk arrays If the server is a simple swap model that contains a SATA RAID back plate you can use the LSI Logic Configuration Utility program to configure the simple swap SATA hard disk drives For information about configuring an integrated Gigabit Ethernet controller see Configuring the Gigabit Ethernet controllers on page 55 Chapter 2 Installing optional devices 39 40 IBM System x3250 M2 Types 4190 and 4194 User s Guide Chapter 3 Configuring the server The following configuration programs come with the server e IBM ServerGuide Setup and Installation CD The ServerGuide program provides software setup tools and installation tools that are designed for the server Use this CD during the installation of the server to configure basic hardware features and to simplify the installation of your operating system For information about using this CD see ServerGuide Setup and Installation CD on page 42 Configuration Setup Utility program The Configu
18. then while you pull the tab pull the drive out of the bay Note You might have to push the right rear corner of the drive toward the front of the server to move the drive initially IBM System x3250 M2 Types 4190 and 4194 User s Guide Drive retention clip cw Alignment pins 4 Remove the retention clip from the drive and save it for future use To install a CD or DVD drive complete the following steps 1 Read the safety information that begins on page v and Installation guidelines on page 20 2 Make sure that the server and peripheral devices are turned off and that the power cords and all external cables are disconnected Remove the cover see Removing the cover on page 22 3 Follow the instructions that come with the drive to set any jumpers or switches Drive retention clip Alignment pins 4 Attach the drive retention clip to the side of the drive 5 Slide the drive into the CD DVD drive bay until the drive clicks into place If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 38 Installing an optional PCI X riser card assembly The server comes with a PCI Express riser card assembly installed You can remove the assembly and install an optional PCI X assembly See http www ibm com servers eserver serverproven compat us for a list of riser card assemblies you can install in the server The PCI X riser card
19. you might have to configure the settings again 1 2 n s Review the safety information that begins on page Turn off the server and peripheral devices and disconnect all power cords and external cables Remove the server from the rack and place it on a flat static protective surface Remove the cover See l Removing the cover on page 22 for instructions If necessary remove the riser card assembly See Installing an adapter on page 23 for instructions Move the clear CMOS jumper from pins 1 and 2 to pins 2 and 3 and leave it there for at least 5 seconds then move the clear CMOS jumper back to pins 1 and 2 Reinstall the riser card assembly and cover See Installing an adapter on page 23 for instructions Replace the server in the rack and connect the server to a keyboard monitor and mouse then connect the server to a power source Turn on the server You can now start the Configuration Setup Utility program and either delete the old password or set a new power on or administrator password Using the WebBIOS Configuration Utility Use the WebBIOS Configuration Utility program to configure hot swap hard disk drives that are connected to the ServeRAID MR10i controller 50 To start the WebBIOS Configuration Utility program complete the following steps 1 Turn on the server IBM System x3250 M2 Types 4190 and 4194 User s Guide 2 When the prompt Press CTRL H to start WebBIOS Configuration Util
20. 20000 C Ethernet 1 activity LED Ethernet 2 link LED Ethernet 2 activity LED Ethernet 1 link LED Ethernet activity LED This LED is on each Ethernet connector When this LED is lit it indicates that there is activity between the server and the network Ethernet link LED This LED is on each Ethernet connector When this LED is lit it indicates that the Ethernet controller is connected to the network The following illustration shows the connectors on the rear of the server Power cord connector W UI o Ferge O H O00000000000000 nononono cero ef PEB 000 900000000000000000 BJO CURIS LES Lo Systems management USB 3 connector Serial connector onnector CONN USB 4 connector Video connector Ethernet 2 connector Ethernet 1 connector Power cord connector Connect the power cord to this connector Serial connector Connect a 9 pin serial device to this connector Video connector Connect a monitor to this connector Ethernet connector Use either of these connectors to connect the server to a network Ethernet connector 1 supports Serial over LAN SOL USB connector Connect a USB d
21. ATA SATA controller simple swap SATA models Serial attached SCSI SAS controller with integrated RAID hot swap SAS SATA models that supports RAID levels 0 1 1E Environment Air temperature Server on 10 to 35 C 50 0 to 95 0 F altitude O to 914 4 m 3000 ft Server on 10 to 32 C 50 0 to 89 6 F altitude 914 4 m 3000 ft to 2133 6 m 7000 ft Server off 10 to 43 C 50 0 to 109 4 F maximum altitude 2133 6 m 7000 ft Shipping 40 to 60 C 40 to 140 F maximum altitude 2133 6 m 7000 ft Humidity Server on 8 to 80 Server off 8 to 80 Acoustical noise emissions Sound power idling 6 5 bel maximum Sound power operating 6 5 bel maximum Heat output Approximate heat output in British thermal units Btu per hour Minimum configuration 341 Btu per hour 100 watts Maximum configuration 1024 Btu per hour 300 watts Electrical input Sine wave input 50 60 Hz required Input voltage low range Minimum 100 V ac Maximum 127 V ac Input voltage high range Minimum 200 V ac Maximum 240 V ac Approximate input kilovolt amperes KVA Minimum 0 102 kVA Maximum 0 55 kVA Notes 1 Power consumption and heat output vary depending on the number and type of optional features that are installed and the power management optional features that are in use 2 These levels were measured in
22. CZEERI BId 650c4 CORR HAAANYT U CESE ito IJ 6 U S 2 VO EF amp 5EGD CU S LOT EU AIN 9 OS RE e dU 3 IOGA HARA IKE EIERE EIE ABE SWEBMHS CE RIDE 1520 YTU I RioTv CU xS In accordance with the European Directive 2006 66 EC batteries and accumulators are labeled to indicate that they are to be collected separately and recycled at end of life The label on the battery may also include a chemical symbol for the metal concerned in the battery Pb for lead Hg for mercury and Cd for cadmium Users of batteries and accumulators must not dispose of batteries and accumulators as unsorted municipal waste but use the collection framework available to customers for the return recycling and treatment of batteries and accumulators Customer participation is important to minimize any potential effects of batteries and accumulators on the environment and human health due to the potential presence of hazardous substances For proper collection and treatment contact your local IBM representative For California Perchlorate material special handling may apply Seelhttp www dtsc ca gov hazardouswaste perchlorate The foregoing notice is provided in accordance with California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials This product part may include a lithium manganese dioxide battery which contains a perchlorate substance Appendix Notices 61 German Ordinance for Work glos
23. However they do not have to be the same size speed type and technology as the DIMMs that are installed in DIMM connectors 1 and 3 You can use compatible DIMMs from various manufacturers in the same pair Install only double data rate II DDR II PC2 5300 unbuffered synchronous dynamic random access memory SDRAM with error correcting code ECC DIMMs These DIMMs must be compatible with the latest PC2 5300 SDRAM unbuffered DIMM specification If you install a pair of 2 GB DIMMs and a pair of other size DIMMs the 2 GB DIMMs must be installed as the first pair in DIMM connectors 1 and 3 36 IBM System x3250 M2 Types 4190 and 4194 User s Guide When you restart the server after you add or remove a DIMM a message is displayed indicating that the memory configuration has changed To remove a DIMM complete the following steps 1 Read the safety information that begins on page vand Installation guidelines on page 20 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables Remove the cover see Removing the cover on page 22 Attention To avoid breaking the retaining clips or damaging the DIMM connectors open and close the clips gently 3 Open the retaining clip on each end of the DIMM connector 4 Lift the DIMM out of the connector To install a DIMM complete the following steps 1 Read the safety information that begins on page vj and Installation guidelines
24. When you make changes through other choices in the Configuration Setup Utility program some of those changes are reflected in the system information you cannot change settings directly in the system information This choice is on the full Configuration Setup Utility menu only IBM System x3250 M2 Types 4190 and 4194 User s Guide Devices and I O Ports Select this choice to view or change assignments for devices and input output I O ports to configure remote console redirection to enable or disable integrated Ethernet controllers and all standard ports such as serial and USB and to view the system MAC addresses If you disable a device it cannot be configured and the operating system will not be able to detect it this is equivalent to disconnecting the device If you disable the integrated Ethernet controllers and no Ethernet adapter is installed the server will have no Ethernet capability For a SATA model you can also select this choice to view or change the interface mode for a SATA port To view or change the mode select Programming Interface for a SATA Port Native mode Standard PCI resource steering is used Combined mode Native mode plus legacy mode is used In legacy mode standard IDE I O and IRQ resources IRQ 14 and 15 are assigned This choice is on the full Configuration Setup Utility menu only Date and Time Select this choice to set the date and time in the server in 24 hour format hour minut
25. address if you want to limit the connection requests that will be accepted by the utility program To accept connections from any server type INADDR_ANY as the IP address Also specify the port number that the utility program will use These values will be recorded in the smbridge cfg file for the automatic startup of the utility program To install the Avocent SMBridge management utility program on a server running a Linux operating system complete the following steps You must be logged in as a root user to perform these procedures 1 Go to http www ibm com systems support download the management utility program and create the BMC Management Utility CD 2 Insert the BMC Management Utility CD into the drive Type mount mnt cdrom 4 Locate the directory where the installation RPM package is located and type cd mnt cdrom 5 Type the following command to run the RPM package and start the installation rpm ivh smbridge 2 0 xx rpm e where xx is the release level that is being installed 6 Follow the prompts to complete the installation When the installation is complete the utility copies files to the following directories etc init d SMBridge etc smbridge cfg usr sbin smbridged Nar log smbridge LICENSE The utility starts automatically when the server is started You can also locate the ect init d directory to start the utility and use the following commands to manage the utility smbridge status smbridge start
26. controlled acoustical environments according to the procedures that are specified by the American National Standards Institute ANSI 12 10 and ISO 7779 and are reported in accordance with ISO 9296 Actual sound pressure levels in a given location might exceed the average stated values because of room reflections and other nearby noise sources The declared sound power levels indicate an upper limit below which a large number of computers will operate 3 There is no keyboard connector or mouse connector on the server You can connect a USB keyboard and USB mouse to the server by using the USB connectors 4 IBM System x3250 M2 Types 4190 and 4194 User s Guide What your server offers The server uses the following features and technologies Baseboard management controller The baseboard management controller provides basic service processor environmental monitoring functions If an environmental condition exceeds a threshold or if a system component fails the baseboard management controller lights LEDs to help you diagnose the problem Critical errors are also included in the error log Note In messages and documentation the term service processor refers to the baseboard management controller or the optional Remote Supervisor Adapter II SlimLine IBM Director IBM Director is a workgroup hardware management tool that you can use to centrally manage servers For more information see the IBM Director documentation on the
27. cords to outlet 4 Remove all cables from devices 5 Turn device ON Safety vii Statement 2 CAUTION When replacing the lithium battery use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer If your system has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repair or disassemble Dispose of the battery as required by local ordinances or regulations Viii IBM System x3250 M2 Types 4190 and 4194 User s Guide Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable parts inside the device Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Class 3A or Class 3B laser diode Note the following Laser radiation when open Do not stare into the beam do not view directly with optical instruments and avoid direct exposure to the beam A Class 1 Lase
28. damage to the hard disk drive connectors make sure that the cover is in place and fully closed whenever you install or remove a hard disk drive 1 Read the safety information that begins on page vand Installation guidelines on page 20 2 Make sure that the server cover is in place and fully closed 3 Turn off the server and peripheral devices and disconnect the power cord and all external cables 4 Remove the filler panel from the bay 5 Pullthe loops of the drive tray toward each other and slide the drive into the server until the drive connects to the back plate 6 Release the loops of the drive tray 7 Insert the filler panel into the bay to cover the drive If you have other devices to install do so now Otherwise go to Completing the installation on page 38 Note If a RAID controller or adapter is installed you might have to reconfigure the disk arrays after you install hard disk drives See your RAID controller or adapter documentation To remove a simple swap SATA drive from the bay complete the following steps 1 Read the safety information that begins on page vjand Installation guidelines on page 20 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the filler panel from the bay IBM System x3250 M2 Types 4190 and 4194 User s Guide 4 Pull the loops of the drive tray toward each other and pull the tray out of the bay
29. k telep t se el tt olvassa el a Biztons gi el r sokat Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza HRMOMBORMI HERRE BRA HEN HSS So AH OM ASS ACMA IIpez ma ce MHCTasIMpa OBO HPOAYKT rrpouurajre nu opmannjaTa 3a 6es6e mocr Les sikkerhetsinformasjonen Safety Information f r du installerer dette produktet Przed zainstalowaniem tego produktu nale y zapozna si z ksi k Informacje dotycz ce bezpiecze stwa Safety Information Antes de instalar este produto leia as Informa es sobre Seguran a llepen yctaHOBKOM nponykra NPOYTUTE UHCTPYKLIUM no TEXHUKE 6OesonacHocTM Pred in tal ciou tohto zariadenia si pecitaje Bezpe nostn predpisy Pred namestitvijo tega proizvoda preberite Varnostne informacije Copyright IBM Corp 2007 2008 vi Antes de instalar este producto lea la informaci n de seguridad Las sakerhetsinformationen innan du installerar den har produkten Important Each caution and danger statement in this document is labeled with a number This number is used to cross reference an English language caution or danger statement with translated versions of the caution or danger statement in the Safety Information document For example if a caution statement is labeled Statement 1 translations for that caution statement are in the Safety Information document under Statement 1 Be sure to read all caution and danger statemen
30. that the BMC code was created BMC Build Level This is a nonselectable menu item that displays the version of the BMC code Existing Event Log number This is a nonselectable menu item that displays the number of entries in the BMC system event log BMC POST Watchdog Enable or disable the mini BMC POST watchdog Disable is the default setting IBM System x3250 M2 Types 4190 and 4194 User s Guide System BMC Serial Port Sharing Select this choice to specify whether the serial port that the BMC uses is shared with the rest of the system or is dedicated to the BMC This choice together with the BMC Serial Port Access Mode setting affects serial related behavior and remote management capabilities on this server For more information see the help for this choice BMC Serial Port Access Mode Select this choice to specify the access mode for the serial port This choice together with the System BMC Serial Port Sharing setting affects serial related behavior and remote management capabilities on this server For more information see the help for this choice Reboot System on NMI Select this choice to enable or disable the ability of the server to restart after an NMI interrupt is issued If the value is Enabled this setting supersedes the automatic server restart ASR setting User Account Settings Select this choice to view the settings for each BMC user ID change the password for a BMC user ID and set the maximum BMC
31. to remove the PCI X riser card assembly from the server disconnect the riser card power cable from the assembly first then grasp the front and rear edges of the assembly and lift the assembly out of the server If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 38 Installing a memory module The following notes describe the types of dual inline memory modules DIMMs that the server supports and other information that you must consider when you install DIMMs The server supports 512 MB 1 GB and 2 GB DIMMs for a maximum of 8 GB of er memory See http www ibm com servers eserver serverproven compat for a list of memory modules that you can use with the server The amount of usable memory will be reduced depending on the system configuration A certain amount of memory must be reserved for system resources Use the system summary in the Configuration Setup Utility program to view the total amount of installed memory and the amount of configured memory see Using the Configuration Setup Utility program on page 44 The server comes with one 512 MB or 1 GB DIMM installed in DIMM connector 1 and an identical DIMM the same size speed type and technology installed in DIMM connector 3 If you install a pair of DIMMs in DIMM connectors 2 and 4 the size speed type and technology of the DIMMs that you install in DIMM connectors 2 and 4 must match each other
32. you must install a device driver to enable the operating system to address the controllers For device drivers and information about configuring the Ethernet controllers see the Broadcom NetXtreme II Gigabit Ethernet Software CD that comes with the server To find updated information about configuring the controllers complete the following steps Note Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this document 1 Go to http www ibm com systems support 2 Under Product support click System x 3 Under Popular links click Publications lookup 4 From the Product family menu select System x3250 M2 and click Continue Updating IBM Director If you plan to use IBM Director to manage the server you must check for the latest applicable IBM Director updates and interim fixes To install the IBM Director updates and any other applicable updates and interim fixes complete the following steps Note Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this document 1 Check for the latest version of IBM Director a Go to http www ibm com systems management downloads htmi Chapter 3 Configuring the server 55 56 b If a newer version of IBM Director than what comes with the server is shown in the drop down list follow the instructions on the Web page to download the latest version
33. your operating system CD to install the operating system The ServerGuide program performs the following tasks Sets system date and time Detects the SAS RAID adapter controller or integrated SAS SATA controller with RAID capabilities and runs the SAS RAID configuration program Checks the microcode firmware levels of a ServeRAID adapter and determines whether a later level is available from the CD Detects installed optional hardware devices and provides updated device drivers for most adapters and devices Provides diskette free installation for supported Windows operating systems Includes an online readme file with links to tips for your hardware and operating system installation IBM System x3250 M2 Types 4190 and 4194 User s Guide Setup and configuration overview When you use the ServerGuide Setup and Installation CD you do not need setup diskettes You can use the CD to configure any supported IBM server model The setup program provides a list of tasks that are required to set up your server model On a server with a SAS SATA controller with RAID capabilities you can run the LSI Logic Configuration Utility program to create logical drives Note Features and functions can vary slightly with different versions of the ServerGuide program When you start the ServerGuide Setup and Installation CD the program prompts you to complete the following tasks Select your language Select your keyboard layout and co
34. 2 Install IBM Director 3 Download and install any applicable updates or interim fixes for the server a b C d sep e Go to http www ibm com systems support Under Product support click System x Under Popular links click Software and device drivers Click Director downloads to display the matrix of downloadable files for the Server Select any applicable update or interim fix that you want to download Click the file link for the executable file to download the file and follow the instructions in the readme file to install the update or interim fix Repeat steps Be ana si for any additional updates or interim fixes that you want to install IBM System x3250 M2 Types 4190 and 4194 User s Guide Appendix Notices Trademarks This information was developed for products and services offered in the U S A IBM may not offer the products services or features discussed in this document in other countries Consult your local IBM representative for information on the products and services currently available in your area Any reference to an IBM product program or service is not intended to state or imply that only that IBM product program or service may be used Any functionally equivalent product program or service that does not infringe any IBM intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any non IBM product progr
35. 4 server is a 1 U high server that is ideally suited for networking environments that require superior microprocessor performance efficient memory management and flexibility Performance ease of use reliability and expansion capabilities were key considerations in the design of the server These design features make it possible for you to customize the system hardware to meet your needs today and provide flexible expansion capabilities for the future The server comes with a limited warranty For information about the terms of the warranty and getting service and assistance see the Warranty and Support Information document The server contains IBM X Architecture technologies which help increase performance and reliability For more information see pecs Slana Reliability availability and serviceability features on page 6 You can obtain up to date information about the server and other IBM server products at http www ibm com systems x Related documentation This User s Guide contains general information about the server including how to install supported optional devices and how to configure the server The following documentation also comes with the server Installation Guide This printed document contains instructions for setting up the server and basic instructions for installing some optional devices Warranty and Support Information This document is in Portable Document Format PDF on the System x
36. Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this document 1 Go tolhttp www ibm com systems support 2 Under Product support click System x 3 Under Popular links click Software and device drivers 4 Click System x3250 M2 to display the matrix of downloadable files for the server For additional information about tools for updating managing and deploying firmware see the System x and xSeries Tools Center at Before you install optional hardware make sure that the server is working correctly Start the server and make sure that the operating system starts if an operating system is installed or that a 19990305 error code is displayed indicating that an operating system was not found but the server is otherwise working correctly If the server is not working correctly see Solving Problems in the Installation Guide for diagnostic information Observe good housekeeping in the area where you are working Place removed covers and other parts in a safe place f you must start the server while the cover is removed make sure that no one is near the server and that no tools or other objects have been left inside the server IBM System x3250 M2 Types 4190 and 4194 User s Guide Do not attempt to lift an object that you think is too heavy for you If you have to lift a heavy object observe the following precautions Make sure that y
37. PCI Express bus 23 administrator password 45 49 attention notices 2 baseboard management controller utility programs 53 battery return program 60 bays 4 bypassing an unknown password 49 C caution statements 2 CD drive See CD DVD drive CD eject button 9 CD DVD drive activity LED 9 replacing 32 specification 4 Class A electronic emission notice 62 command line interface commands connect 54 help 54 identify 54 power 54 power off 54 power on 54 reboot 55 sel 55 sensor 55 sysinfo 55 using 54 configuration Configuration Setup Utility 44 RAID 39 41 42 43 51 with ServerGuide 43 Configuration Setup Utility program 44 configuring hot swap SAS or SATA devices 51 SAS SATA controller 51 connectors 9 external 17 front 38 internal 15 optional device on system board 19 rear 39 controller Ethernet configuring 55 network support 5 type 4 Copyright IBM Corp 2007 2008 controller continued hard disk drive 4 SAS 4 SATA 4 video 4 cover installing 38 removing 22 D danger statements 2 device drivers 8 DIMMs installing 37 removing 37 supported 4 drives 4 5 DVD drive See CD DVD drive E electrical input 4 electronic emission Class A notice 62 environment 4 Ethernet activity LED 9 connector 9 controller 4 5 link LED 9 expansion bays 4 expansion slots 4 F FCC Class Anotice 62 features 3 and specifications 3 RAS 6 ServerGuide 42 firmware code updating 53 forgotten passwor
38. This choice is on the full Configuration Setup Utility menu only Advanced Setup Select this choice to change settings for advanced hardware features Important The server might malfunction if these choices are incorrectly configured Follow the instructions on the screen carefully This choice is on the full Configuration Setup Utility menu only CPU Options Select this choice to enable or disable core multiprocessing the execute disable bit capability and other microprocessor functions PCI Bus Control Select this choice to view the system resources that are used by installed PCI devices RSA II Settings This choice is displayed only when a Remote Supervisor Adapter II SlimLine is installed in the server Select this choice to view the IP address DHCP settings and gateway settings for the Remote Supervisor Adaptor II SlimLine and to view or change the DHCP control static IP address subnet mask gateway static IP address and operating system USB selections for the Remote Supervisor Adapter II SlimLine Baseboard Management Controller BMC Settings Select this choice to change Intelligent Platform Management Interface IPMI settings for the mini BMC controller IPMI Specification Version This is a nonselectable menu item that displays the IPMI version BMC Firmware Version This is a nonselectable menu item that displays the BMC firmware version BMC Build Date This is a nonselectable menu item that displays the date
39. am or service IBM may have patents or pending patent applications covering subject matter described in this document The furnishing of this document does not give you any license to these patents You can send license inquiries in writing to IBM Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it be
40. and l Installation guidelines on page 20 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the cover see l Removing the cover on page 22 IBM System x3250 M2 Types 4190 and 4194 User s Guide Power cable PCI X slot If the riser card assembly is an optional PCI X riser card assembly disconnect the riser card power cable from the riser card assembly Riser card assembly LE EE x s Zs Grasp the riser card assembly at the front and rear edges and lift to remove it from the server Place the riser card assembly on a flat static protective surface Remove the expansion slot cover from the slot that you intend to use Attention PCI expansion slot covers must be installed on all vacant slots This maintains the electronic emissions characteristics of the server and ensures proper cooling of server components Touch the static protective package that contains the adapter to any unpainted metal surface on the server Then remove the adapter from the static protective package Avoid touching the components and gold edge connectors on the adapter Place the adapter component side up on a flat static protective surface and set any jumpers or switches as described by the adapter manufacturer if necessary Carefully grasp the adapter by its top edge or upper corners and align it with the expansion slot in the riser card assembly then press the adap
41. assembly provides one PCI X expansion slot on the riser card Install only a PCI X or PCI adapter in the expansion slot To install a PCI X riser card assembly complete the following steps 1 Read the safety information that begins on page vjana Installation guidelines 2 Turn off the server and peripheral devices and disconnect the power cord and all external cables 3 Remove the cover see Removing the cover on page 22 Chapter 2 Installing optional devices 33 4 Install the PCI X riser card power cable a Separate the P4 connector on the cable that connects the power supply to the CD DVD interposer card b Connect the short 4 wire length of the riser card power cable El to EJ to the two halves of the P4 connector as shown in the illustration c Make sure that the long 2 wire section EJ to KR reaches the riser card assembly Route the cable between fans 4 and 5 to reach the assembly Riser card assembly D LE LE 5 Touch the static protective package that contains the PCI X riser card assembly to any unpainted metal surface on the server Then remove the assembly from the static protective package Avoid touching the components and gold edge connectors on the assembly 34 IBM System x3250 M2 Types 4190 and 4194 User s Guide 6 Install a PCI X or PCI adapter if you have one available a e Remove the expansion slot cover from the PCI X slot on the assembly Attention PCI expa
42. at 1 800 426 4333 Have the IBM part number listed on the battery available prior to your call For Taiwan Please recycle batteries wa BE we wk For the European Union IBM System x3250 M2 Types 4190 and 4194 User s Guide Notice This mark applies only to countries within the European Union EU Batteries or packaging for batteries are labeled in accordance with European Directive 2006 66 EC concerning batteries and accumulators and waste batteries and accumulators The Directive determines the framework for the return and recycling of used batteries and accumulators as applicable throughout the European Union This label is applied to various batteries to indicate that the battery is not to be thrown away but rather reclaimed upon end of life per this Directive Les batteries ou emballages pour batteries sont tiquet s conform ment aux directives europ ennes 2006 66 EC norme relative aux batteries et accumulateurs en usage et aux batteries et accumulateurs us s Les directives d terminent la marche suivre en vigueur dans l Union Europ enne pour le retour et le recyclage des batteries et accumulateurs us s Cette tiquette est appliqu e sur diverses batteries pour indiquer que la batterie ne doit pas tre mise au rebut mais plut t r cup r e en fin de cycle de vie selon cette norme AyTU d Uli yTU RO y 7 Z7I I EU HEIIHT CREME Te JET 2006 66 EC NFA DANTO COP NYT U EFE BE OBS yTU
43. cify the sequence in which channels are checked during startup to load and execute the ROMs for optional devices This enables you to tailor the ROM load and execution sequence for maximum efficiency Planar PXE DHCP Priority specifies the priority of network related ROMs relative to local PCI device ROMs PCI Device Boot Priority specifies the priority of ROMs for devices connected to the SAS SATA controller on the system board and to adapters in expansion slots 1 and 2 The startup sequence specifies the order in which the server checks devices to find a boot record The server starts from the first boot record that it finds For Chapter 3 Configuring the server 45 46 example you can define a startup sequence that checks for a CD or DVD in the CD or DVD drive then checks the hard disk drive and then checks for a USB key drive flash drive If the server has Wake on LAN hardware and software and the operating system supports Wake on LAN functions you can specify a startup sequence for the Wake on LAN functions If you have not changed the default startup sequence the server starts the devices in the following order the CD or DVD drive then the USB diskette drive USB memory key USB CD drive or USB hard disk drive if you have installed any in the server then the hard disk drives that are connected to the system board then the drives that are connected to the SAS SATA controller then the integrated Ethernet controllers 1 and 2
44. ctor DIMM 2 FINT connector DIMM 3 connector DIMM 4 connector sod ca E il ij SAS SATA I controller card o By EJ e OG CODEN Other systems management adapter connector Remote Supervisor Adapter II SlimLine connector Battery connector SAS SATA controller connector The following illustration shows the locations of the PCI Express slots on the riser card assembly PCI Express x8 slot 1 PCI Express x8 slot 2 Chapter 2 Installing optional devices 19 The following illustration shows the location of the PCI X slot on the optional PCI X riser card assembly gt Power cable PCI X slot Installation guidelines 20 Before you install optional devices read the following information Read the safety information that begins on page Jana the guidelines in Fr sialic sensiive devices l information will help you work safely When you install your new server take the opportunity to download and apply the most recent firmware updates This step will help to ensure that any known issues are addressed and that your server is ready to function at maximum levels of performance To download firmware updates for your server conplete the following steps Note
45. d bypassing 49 G gloss statement Germany 62 H hard disk drive activity LED 8 hot swap SATA 31 installing 29 30 removing 30 SAS 31 65 hard disk drive continued SCSI See SAS simple swap SATA 30 heat output 4 humidity 4 IBM Director 5 7 55 important notices 2 installation order memory modules 36 installing adapter 23 cover 38 DIMMs 36 hard disk drive 29 memory modules 36 integrated controllers 4 functions 4 internal connectors 15 J jumper clear CMOS password override 49 jumpers 16 L LED cd drive activity 9 Ethernet activity 9 Ethernet link 9 hard disk drive activity 8 locator 9 power on 8 System error 9 LEDs front 8 rear 9 local area network LAN 5 locator LED 9 M memory capacity 5 order of installation 36 specifications 4 memory module specifications 36 microprocessor location 15 type 4 N noise emissions 4 66 IBM System x3250 M2 Types 4190 and 4194 User s Guide NOS installation with ServerGuide 43 without ServerGuide 43 notes 2 notes important 58 notices 57 electronic emission 62 FCC ClassA 62 notices and statements 2 O online publications 2 optical drive See CD DVD drive order of installation memory modules 36 P password administrator 49 clear CMOS jumper 49 override 49 power on 48 resetting 49 power requirement 4 supply 4 power control button 8 button shield 8 power cord connector 9 power on LED 8 power o
46. d off manually A power control button shield comes installed around the button to prevent the server from being turned off accidentally You can remove this disk shaped shield if you prefer Reset button Press this button to reset the server and run the power on self test POST You might have to use a pen or the end of a straightened paper clip to press the button Hard disk drive activity LED When this LED is flashing it indicates that a hard disk drive is in use 8 IBM System x3250 M2 Types 4190 and 4194 User s Guide Rear view Locator LED This LED can be lit remotely by the system administrator to aid in visually locating the server You can use IBM Director to light this LED remotely System error LED When this LED is lit it indicates that a system error has occurred An LED on the system board might also be lit to help isolate the error Detailed troubleshooting information is in the Problem Determination and Service Guide that is on the IBM System x Documentation CD USB connectors Connect a USB device to either of these connectors CD eject button Press this button to release a CD from the CD drive CD drive activity LED When this LED is lit it indicates that the CD drive is in use The following illustration shows the LEDs on the rear of the server o OObOO0OOO00 O i US Tboo EHEHERdEHEOR 2 iT m A00500000000000 e o e O0O000 Md 222 gLLIBDBBDO b D B B e NE 239 E0000 O g 000 O0O0000000000000000
47. drive models only WebBIOS Configuration Utility Ctrl H during server startup BIOS Configuration Setup Utility program Ctrl A during server startup ServerGuide WebBIOS Configuration Utility Ctrl H during server startup MegaCLi command line interface Baseboard management controller utility programs Use these programs to configure the baseboard management controller to update the firmware and sensor data record field replaceable unit SDR FRU data and to remotely manage a network For information about using these programs see Using the baseboard management controller on page 52 Ethernet controller configuration For information about configuring the Ethernet controllers see Configuring the Gigabit Ethernet controllers on page 55 O Copyright IBM Corp 2007 2008 41 IBM Director IBM Director is a workgroup hardware management tool that you can use to centrally manage System x servers If you plan to use IBM Director to manage the server you must check for the latest applicable IBM Director updates and interim fixes For information about updating IBM Director see Updating IBMI Director on page 55 For more information about IBM Director see the IBM Director documentation on the BM Director CD that comes with the server Using the ServerGuide Setup and Installation CD The ServerGuide Setup and Installation CD contains a setup and installation program that is designed for yo
48. e second This choice is on the full Configuration Setup Utility menu only System Security Select this choice to set passwords For more information about passwords see Passwords on page 48 This choice is on the full Configuration Setup Utility menu only Administrator Password Select this choice to set or change an administrator password An administrator password is intended to be used by a system administrator it limits access to the full Configuration Setup Utility menu If an administrator password is set the full Configuration Setup Utility menu is available only if you type the administrator password at the password prompt For more information see Administrator password on page 49 Power on Password Select this choice to set or change a power on password For more information see l Power on password on page 48 Startup Options Select this choice to view or change the startup options such as the startup sequence the keyboard NumLock state the option ROM execution priorities whether displayless operation is enabled whether to restart on POST BIOS error and other startup considerations You can also select this choice to enable or disable hard disk drive self monitoring analysis and reporting technology SMART Changes in the startup options take effect when you restart the server Select the option ROM execution priority choices Planar PXE DHCP Priority and PCI Device Boot Priority to spe
49. e sure that the tray handle is open that is perpendicular to the front of the drive Chapter 2 Installing optional devices 31 Align the drive assembly with the guide rails in the bay Gently push the drive assembly into the bay until the drive stops Push the tray handle to the closed locked position Check the hard disk drive status LED to make sure that the hard disk drive is operating correctly If the amber hard disk drive status LED for a drive is lit continuously that drive is faulty and must be replaced If the green hard disk drive activity LED is flashing the drive is being accessed If you have other devices to install do so now Otherwise go to Completing the installation on page 38 oap o Installing a new CD or DVD drive 32 The server comes with a CD or CD DVD drive installed You can remove the drive and install a different one See http www ibm com servers eserver serverproven compat us for a list of CD or CD DVD drives you can use with the server To remove a CD or CD DVD drive complete the following steps Release tab 1 Read the safety information that begins on page vj and Installation guidelines on page 20 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables Remove the cover see Removing the cover on page 22 3 Pull the release tab the rear of the drive retention clip toward the right side of the server to release the clip
50. eature the Wake on LAN feature can turn on the server Note When 4 GB or more of memory physical or logical is installed some memory is reserved for various system resources and is unavailable to the operating system The amount of memory that is reserved for system resources depends on the operating system the configuration of the server and the configured PCI optional devices Turning off the server When you turn off the server and leave it connected to ac power the server can respond to requests from the service processor such as a remote request to turn on the server While the server remains connected to ac power one or more fans might continue to run To remove all power from the server you must disconnect it from the power source Some operating systems require an orderly shutdown before you turn off the server See your operating system documentation for information about shutting down the operating system IBM System x3250 M2 Types 4190 and 4194 User s Guide Statement 5 AA CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 20a 1a The server can be turned off in any of the following ways You can turn off the server from the ope
51. ed Hat based trademarks and logos are trademarks or registered trademarks of Red Hat Inc in the United States and other countries Other company product or service names may be trademarks or service marks of others Important notes 58 Processor speed indicates the internal clock speed of the microprocessor other factors also affect application performance CD or DVD drive speed is the variable read rate Actual speeds vary and are often less than the possible maximum When referring to processor storage real and virtual storage or channel volume KB stands for 1024 bytes MB stands for 1 048 576 bytes and GB stands for 1 073 741 824 bytes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 bytes and GB stands for 1 000 000 000 bytes Total user accessible capacity can vary depending on operating environments Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives that are available from IBM IBM System x3250 M2 Types 4190 and 4194 User s Guide Maximum memory might require replacement of the standard memory with an optional memory module IBM makes no representation or warranties regarding non IBM products and services that are ServerProven including but not limited to the implied warranties of merchantability and fitness for a particular purpose
52. em board optional device Chapter 2 Installing optional devices 23 24 connectors on page 19 for the location of the connector To install the Remote Supervisor Adapter II SlimLine see Installing a Remote Supervisor Adapter II SlimLine on page 27 The server uses a rotational interrupt technique to configure PCI Express adapters so that you can install PCI Express adapters that do not support sharing of interrupts An optional ServeRAID MR10i controller provides RAID level 5 support to the 2 5 inch hot swap drives and supports an external storage enclosure A ServeRAID MR10i controller supports the 2 5 inch hard disk drives without modification An optional IBM SAS HBA Controller adapter enables you to connect external storage devices such as SAS or SATA hard disk drives or tape drives to a simple swap SATA model server The server scans the PCI slots to assign system resources The scan sequence is related to the startup sequence If you have not changed the default startup sequence the server scans the PCI slots in the following order the integrated Ethernet controllers 1 and 2 then the drives that are connected to the SAS SATA controller then PCI Express slots 1 and 2 Expansion slot cover p Adapter Adapter support bracket Expansion slot 1 Riser card assembly Expansion slot 2 To install an adapter complete the following steps 1 Read the safety information that begins on pageM
53. em when you work inside the server with the power on You might be instructed to turn on the server while the cover is off to look at system board LEDs Follow these guidelines when you work inside a server that is turned on Avoid wearing loose fitting clothing on your forearms Button long sleeved shirts before working inside the server do not wear cuff links while you are working inside the server Do not allow your necktie or scarf to hang inside the server Remove jewelry such as bracelets necklaces rings and loose fitting wrist watches Remove items from your shirt pocket such as pens and pencils that could fall into the server as you lean over it Avoid dropping any metallic objects such as paper clips hairpins and screws into the server Handling static sensitive devices Attention Static electricity can damage the server and other electronic devices To avoid damage keep static sensitive devices in their static protective packages until you are ready to install them To reduce the possibility of damage from electrostatic discharge observe the following precautions Limit your movement Movement can cause static electricity to build up around you The use of a grounding system is recommended For example wear an electrostatic discharge wrist strap if one is available Handle the device carefully holding it by its edges or its frame Do not touch solder joints pins or exposed circuit
54. erial ATA hard disk drive Installing a hot swap hard disk drive Installing a new CD or DVD drive Installing an optional PCI X riser card assembly Installing a memory module Completing the installation Installing the cover Connecting the cables Updating the server configuration Chapter 3 Configuring the server Using the ServerGuide Setup and Installation CD ServerGuide features fos Ja ode ox Setup and configuration overview Typical operating system installation Installing your operating system without using ServerGuide Using the Configuration Setup Utility program Starting the Configuration Setup Utility program Configuration Setup Utility menu choices Passwords Using the WebBIOS Configuration Utility Using the LSI Logic Configuration Utility program Starting the LSI Logic Configuration Utility program Copyright IBM Corp 2007 2008 OCOOWDWDAOAN DAWN lt iv Configuring the controller and devices Using the baseboard management controller Installing the SMBridge management utility program Using the baseboard management controller utility programs Configuring the Gigabit Ethernet controllers TRE Updating IBM Director P devo Appendix Notices Trademarks Important notes Product recycling and disposal Battery return program German Ordinance for Work gloss statement Electronic emission notices P ee As ud Federal Communications Commiss
55. evice to either of these connectors Chapter 1 The System x3250 M2 Types 4190 and 4194 9 Systems management connector Connect the server to a network for systems management information control This connector is active only if you have installed a Remote Supervisor Adapter II SlimLine and it is used only by the Remote Supervisor Adapter II SlimLine Server power features 10 When the server is connected to an ac power source but is not turned on the operating system does not run and all core logic except for the service processor is shut down however the server can respond to requests from the service processor the baseboard management controller such as a remote request to turn on the server Turning on the server Approximately 20 seconds after the server is connected to ac power the power control button becomes active and one or more fans might start running to provide cooling while the server is connected to power You can turn on the server and start the operating system by pressing the power control button The server can also be turned on in any of the following ways f a power failure occurs while the server is turned on the server will restart automatically when power is restored f your operating system supports the systems management software for an optional Remote Supervisor Adapter II SlimLine the systems management software can turn on the server f your operating system supports the Wake on LAN f
56. h the connector on the system board At a downward angle insert the free end of the adapter under the tab on the mounting bracket aligning the holes in the adapter with the posts on the mounting bracket Rotate the front end of the adapter into the front mounting bracket aligning the holes in the adapter with the posts on the front mounting bracket IBM System x3250 M2 Types 4190 and 4194 User s Guide 8 Press the Remote Supervisor Adapter II SlimLine firmly into the connector and make sure that all tabs on both mounting brackets secure the adapter in place Attention Incomplete insertion might cause damage to the server or the adapter 9 If a three quarter length adapter is installed in expansion slot 1 on the riser card assembly remove it You can replace it with a half length adapter if you choose to do so 10 Carefully align the riser card assembly with the guides on the rear of the server and with the riser card connectors on the system board then press down on the assembly Make sure that the riser card assembly is fully seated in the riser card connectors on the system board Power cable PCI X slot 11 If the riser card assembly is an optional PCI X riser card assembly in the server reconnect the riser card power cable to the riser card assembly Note If you have to remove the Remote Supervisor Adapter II SlimLine spread the mounting bracket retention latches as you lift the Remote Supervisor Adapter II SlimLine
57. has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures European Community contact IBM Technical Regulations Pascalstr 100 Stuttgart Germany 70569 Telephone 0049 0 711 785 1176 Fax 0049 0 711 785 1283 E mail tjahn de ibm com Taiwanese Class A warning statement EEA GAP RA SURE e gt J amp HE SG Soe PAA gt T RE RE RAR THE gt A ERANT gt 18 AA GER RAR RUE ui dp gp Chinese Class A warning statement R A tA A SR EEE TATT nn Al BE EG 702 TN HERS RSH PH FR BU Bt o Appendix Notices 63 Japanese Voluntary Control Council for Interference VCCI statement TOREJ FPRMBRESERESSEMARBS VCCI SOSSI BOC VIAARRINRE CT CORE TRER CHAT b EERIE E 214525015550 c OS amp I 3f FHEEDSSLUL TIE SR EBT DI JER Korean Class A warning statement OIE 47892 HII A SSE VE 22 OSL BOA SE Nee OAS FSAI Heth 29 SE eos Wile 9s 2l HM HARESS D MD daue 64 IBM System x3250 M2 Types 4190 and 4194 User s Guide Index A adapter installing 23
58. ility program If you have not saved the changes that you have made in the settings you are asked whether you want to save the changes or exit without saving them Passwords From the System Security choice you can set change and delete a power on password and an administrator password The System Security choice is on the full Configuration Setup Utility menu only If you set only a power on password you must type the power on password to complete the system startup you have access to the full Configuration Setup Utility menu An administrator password is intended to be used by a system administrator it limits access to the full Configuration Setup Utility menu If you set only an administrator password you do not have to type a password to complete the System startup but you must type the administrator password to access the Configuration Setup Utility menu If you set a power on password for a user and an administrator password for a system administrator you can type either password to complete the system startup A system administrator who types the administrator password has access to the full Configuration Setup Utility menu the system administrator can give the user authority to set change and delete the power on password A user who types the power on password has access to only the limited Configuration Setup Utility menu the user can set change and delete the power on password if the system administrator has given the
59. installation Installing your operating system without using ServerGuide If you have already configured the server hardware and you are not using the ServerGuide program to install your operating system complete the following steps to download the latest operating system installation instructions from the IBM Web site Note Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this document 1 Go to http www ibm com systems support 2 Under Product support click System x 3 From the menu on the left side of the page click System x support search Chapter 3 Configuring the server 43 e From the Task menu select Install From the Product family menu select System x3250 M2 From the Operating system menu select your operating system and then click Search to display the available installation documents Using the Configuration Setup Utility program Use the Configuration Setup Utility program to perform the following tasks View configuration information View and change assignments for devices and I O ports Set the date and time Set and change passwords View and change the startup characteristics of the server and the order of startup devices startup drive sequence View and change settings for advanced hardware features View and clear the event and error logs Change interrupt request IRQ settings Resolve configuration conflicts Starting
60. ion FCC statement Industry Canada Class A emission compliance statement Avis de conformit la r glementation d Industrie Canada Australia and New Zealand Class A statement United Kingdom telecommunications safety requirement European Union EMC Directive conformance statement Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference VCCI statement Korean Class A warning statement Index IBM System x3250 M2 Types 4190 and 4194 User s Guide Safety Before installing this product read the Safety Information Aga Ga dull del Gang giall Ida Cus 5 J Antes de instalar este produto leia as Informa es de Seguran a REN KZT wi Safety Information GEHE S KEKE DAT gt GAME RATA Prije instalacije ovog produkta obavezno pro itajte Sigurnosne Upute Pred instalac tohoto produktu si p e t te p ru ku bezpe nostn ch instrukc L s sikkerhedsforskrifterne for du installerer dette produkt Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dieses Produkts die Sicherheitshinweise lesen Mpv ykaraotrjoete ro ripoi v aut LaBGOTE TIG MANPO opies aop Aeiaq safety information mmean mami ns 183p NT 1810 PINNU 397 A term
61. ity is displayed press Ctrl H If you have set an administrator password you are prompted to type the password 3 Follow the instructions on the screen Using the LSI Logic Configuration Utility program Use the LSI Logic Configuration Utility program to configure hot swap hard disk drives that are connected to the SAS SATA controller Important e If the server is a simple swap SATA model that contains a SATA RAID back plate you can use the LSI Logic Configuration Utility program to configure the simple swap SATA hard disk drives f you install an optional RAID controller in the server such as the ServeRAID MR10i controller use the configuration software that comes with the adapter to configure the hard disk drives Starting the LSI Logic Configuration Utility program To start the LSI Logic Configuration Utility program complete the following steps 1 Turn on the server 2 When the prompt Press CTRL C to start LSI Logic Configuration Utility is displayed press Ctrl C If you have set an administrator password you are prompted to type the password 3 Use the arrow keys to select the adapter SAS controller for which you want to change settings Use the Help function to see instructions and available actions for this screen 4 To change the settings of the selected items follow the instructions on the Screen 5 Press Enter to save your changes Configuring the controller and devices To configure a SAS c
62. l attached SCSI SAS depending on the server model or up to four 63 5 mm 2 5 inch hard disk drives SAS depending on the server model ServeRAID support The hot swap models of this server contain an internal SAS controller that supports level 0 and level 1 redundant array of independent disks RAID configurations The server also supports some ServeRAID adapters and other optional devices to create RAID configurations For a list of supported ServeRAID devices for the server see http www ibm com servers eserver serverproven Chapter 1 The System x3250 M2 Types 4190 and 4194 5 Dynamic System Analysis DSA Preboot diagnostic programs The DSA diagnostic programs are provided on the Dynamic System Analysis Preboot CD The diagnostic programs test the major components of the server and collect the following information about the server System configuration Network interfaces and settings Installed hardware Service processor status and configuration Vital product data firmware and BIOS configuration Hard disk drive health RAID controller configuration Event logs for ServeRAID controllers and service processors See the Problem Determination Guide for more information about the DSA Prebood diagnostic programs Systems management capabilities The server supports an optional IBM Remote Supervisor Adapter II SlimLine When this adapter is used with the integrated baseboard ma
63. l devices for the server see http www ibm com servers eserver serverproven compat us System reliability guidelines To help ensure proper system cooling and system reliability make sure that the following requirements are met Each of the drive bays has a drive or a filler panel and electromagnetic compatibility EMC shield installed in it If the server has redundant power each of the power supply bays has a power supply installed in it There is adequate space around the server to allow the server cooling system to work properly Leave approximately 50 mm 2 0 in of open space around the front and rear of the server Do not place objects in front of the fans For proper cooling and airflow replace the server cover before you turn on the server Operating the server for extended periods of time more than 30 minutes with the server cover removed might damage server components You have followed the cabling instructions that come with optional adapters You have replaced a failed fan within 48 hours You have replaced a hot swap drive within 2 minutes of removal Chapter 2 Installing optional devices 21 Working inside the server with the power on Attention Static electricity that is released to internal server components when the server is powered on might cause the server to halt which might result in the loss of data To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding syst
64. lable to provide additional information that is not included in the server documentation These updates are available from the IBM Web site To check for updated documentation and technical updates complete the following steps Note Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this document 1 Goto 2 Under Product support click System x 3 Under Popular links click Publications lookup 4 From the Product family menu select System x3250 M2 and click Continue Notices and statements in this document 2 The caution and danger statements in this document are also in the multilingual Safety Information document which is on the IBM System x Documentation CD Each statement is numbered for reference to the corresponding statement in the Safety Information document The following notices and statements are used in this document Note These notices provide important tips guidance or advice Important These notices provide information or advice that might help you avoid inconvenient or problem situations Attention These notices indicate potential damage to programs devices or data An attention notice is placed just before the instruction or situation in which damage might occur Caution These statements indicate situations that can be potentially hazardous to you A caution statement is placed just before the description of a potentially ha
65. lieves appropriate without incurring any obligation to you The following terms are trademarks of International Business Machines Corporation in the United States other countries or both IBM FlashCopy Tivoli IBM logo i5 OS Tivoli Enterprise e business logo IntelliStation Update Connector Active Memory NetBAY Wake on LAN Active PCI Netfinity XA 32 Copyright IBM Corp 2007 2008 57 Active PCI X Predictive Failure Analysis XA 64 AIX ServerGuide X Architecture Alert on LAN ServerProven XpandOnDemand BladeCenter System x xSeries Chipkill TechConnect Intel Intel Xeon Itanium and Pentium are trademarks or registered trademarks of Intel Corporation in the United States other countries or both Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or both Adobe and PostScript are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States other countries or both UNIX is a registered trademark of The Open Group in the United States and other countries Java and all Java based trademarks are trademarks of Sun Microsystems Inc in the United States other countries or both Adaptec and HostRAID are trademarks of Adaptec Inc in the United States other countries or both Linux is a registered trademark of Linus Torvalds in the United States other countries or both Red Hat the Red Hat Shadow Man logo and all R
66. n password 45 product recycling and disposal 59 publications 1 R RAS features 6 recycling and disposal product 59 reset button 8 resetting passwords 49 riser card connector location 15 location 25 slots 19 riser card installing PCI X 33 RSA II event error log size limitations 48 S SAS hot swap drives 4 hot swap models 4 SATA hot swap 4 simple swap 4 serial connector 9 ServeRAID 5 ServerGuide CD 5 features 42 NOS installation 43 setup 43 using 42 setting clear CMOS password override jumper 49 simple swap Serial ATA hard disk drive 30 size 4 slot locations adapter 19 PCI Express 19 PCI X 20 slots 4 SMBridge management utility program 52 installing 52 specifications 3 standby 6 18 Standby mode 10 statements and notices 2 supervisor password See administrator password switches and jumpers 16 system board internal connectors 15 jumper blocks 16 LEDs 18 optional device connectors 19 switches and jumpers 16 system error LED 9 52 system event log about 47 clearing 47 size limitations 47 systems management 7 systems management connector 10 T temperature 4 trademarks 57 turning off the server 10 turning on the server 10 T V gloss statement 62 U United States electronic emission Class A notice 62 United States FCC Class A notice 62 unknown password bypassing 49 UpdateXpress 8 updating the firmware code 53 USB connector 9 user password 49 See power on password using baseboard managemen
67. nagement controller that comes with the server you can manage the functions of the server locally and remotely The Remote Supervisor Adapter II SlimLine also provides system monitoring event recording and dial out alert capability Reliability availability and serviceability features Three important server design features are reliability availability and serviceability RAS The RAS features help to ensure the integrity of the data that is stored in the server the availability of the server when you need it and the ease with which you can diagnose and repair problems 6 The server has the following RAS features Advanced Configuration and Power Interface ACPI Advanced Desktop Management Interface DMI features Intelligent Plattorm Management Interface IPMI 2 0 support that provides secure remote power on power off and seven standard alerts for components such as fans voltage and thermals Automatic restart after power failure Auto restart initial program load IPL Boot block recovery Built in menu driven configuration and setup programs Cooling fans with speed sensing capability Customer upgradeable basic input output system BIOS code ECC memory Error codes and messages Menu driven diagnostic programs on CD Monitoring support for temperature voltage and fan speed Parity checking on the SAS bus and PCI bus Power on self test POST Read only memory ROM checksums SDRAM with serial presence detect SPD
68. nsion slot covers must be installed on all vacant slots This maintains the electronic emissions characteristics of the server and ensures proper cooling of server components Touch the static protective package that contains the PCI X or PCI adapter to any unpainted metal surface on the server Then remove the adapter from the static protective package Avoid touching the components and gold edge connectors on the adapter Place the adapter component side up on a flat static protective surface and set any jumpers or switches as described by the adapter manufacturer if necessary Carefully grasp the adapter by its top edge or upper corners and align it with the expansion slot in the riser card assembly then press the adapter firmly into the expansion slot Adapter Expansion slot bracket bracket Tab Important Make sure that the U shaped opening in the metal adapter bracket engages the tab on the expansion slot bracket Follow the cabling instructions if any that come with the adapter 7 Carefully align the PCI X riser card assembly with the guides on the rear of the server and with the riser card connectors on the system board then press down on the assembly Make sure that the riser card assembly is fully seated in the riser card connector on the system board Chapter 2 Installing optional devices 35 Power cable PCI X slot 8 Connect the riser card power cable to the PCI X riser card assembly If you have
69. nstallation Instructions that come with the server for detailed information about how to install the server in a rack cabinet Attention Install the server only in a rack cabinet that has perforated doors Do not leave open space above or below an installed server in the rack cabinet To help prevent damage to server components always install a filler panel to cover the open space and to help ensure proper air circulation See the documentation that comes with the rack cabinet for more information 3 Connect the cables and power cords For more information see the cables 4 Update the server configuration See Updating the server configuration on ET 39 for more information Installing the cover To install the cover place it into position and slide it forward Connecting the cables The following illustrations show the locations of the input and output connectors on the front and rear of the server Front USB 1 connector USB 2 connector IEM I Elo B D LA SED OO 0 sii 1883 38 IBM System x3250 M2 Types 4190 and 4194 User s Guide Rear Power cord connector O o Lo er Sooo EREHEHEREH ESO n a e DOSOOOUONOERRES l eee OCDE resi sl cko ese uuu 188
70. o the LAN Type connect ip ip address u username p password help Display a complete list of supported commands identify Control the system locator LED on the front of the server power View the current power status power on I off Turn the server on and off remotely IBM System x3250 M2 Types 4190 and 4194 User s Guide reboot Force the server to restart sel Perform operations with the BMC system event log sensor Display a list of supported sensors and their current status Note Depending on the number of sensors supported this might take some time to gather all the information sysinfo Display general system information that is related to the server and the baseboard management controller Configuring the Gigabit Ethernet controllers The Ethernet controllers are integrated on the system board They provide an interface for connecting to a 10 Mbps 100 Mbps or 1 Gbps network and provide full duplex FDX capability which enables simultaneous transmission and reception of data on the network If the Ethernet ports in the server support auto negotiation the controllers detect the data transfer rate 10BASE T 100BASE TX or 1000BASE T and duplex mode full duplex or half duplex of the network and automatically operate at that rate and mode Note The Ethernet controller for Ethernet connector 1 supports Serial over LAN SOL You do not have to set any jumpers or configure the controllers However
71. ontroller and attached devices select the controller from the initial LSI Logic Configuration Utility program screen then press Enter You can view and change settings for the following items for the selected controller Boot Support Specify the type of boot support that will be in effect disabled BIOS only OS only or both BIOS and OS RAID Properties Create a RAID array from the displayed choices SAS Topology View information about the devices that are directly attached to the selected SAS controller and which devices make up RAID arrays Format and verify an attached device Advanced Adapter Properties View the SAS properties and change the following items for the selected controller Global properties e Cylinder head sector CHS mapping Advanced device properties such as I O timeouts and LUNs to scan Chapter 3 Configuring the server 51 Spin up properties PHY properties Using the baseboard management controller The mini baseboard management controller provides basic environmental monitoring for the server If environmental conditions exceed thresholds or if system components fail the baseboard management controller lights LEDs to help you diagnose the problem and also records the error in the BMC system event log Important If the system error LED on the front of the server is lit but there are no other error indications or you have corrected all errors restart the server If the LED continues to remain li
72. ou can stand safely without slipping Distribute the weight of the object equally between your feet Use a slow lifting force Never move suddenly or twist when you lift a heavy object To avoid straining the muscles in your back lift by standing or by pushing up with your leg muscles Make sure that you have an adequate number of properly grounded electrical outlets for the server monitor and other devices Back up all important data before you make changes to disk drives Have a small flat blade screwdriver available You do not have to turn off the server to install or replace hot plug Universal Serial Bus USB devices Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server open or close a latch and so on Orange on a component or an orange label on or near a component indicates that the component can be hot swapped which means that if the server and operating system support hot swap capability you can remove or install the component while the server is running Orange can also indicate touch points on hot swap components See the instructions for removing or installing a specific hot swap component for any additional procedures that you might have to perform before you remove or install the component When you are finished working on the server reinstall all safety shields guards labels and ground wires For a list of supported optiona
73. privilege level BMC Network Configuration Select this choice to view the mini BMC MAC address IP address subnet mask gateway address host name and DHCP control setting BMC System Event Log Select this choice to view the BMC system event log which contains all system error messages that have been generated Use the arrow keys to move among pages in the log Run the diagnostic programs to get more information about error codes that occur See the Problem Determination and Service Guide on the IBM System x Documentation CD for instructions To clear the BMC system event log select Clear BMC SELs and confirm the selection The BMC system event log is limited in size When the log is full new entries will not overwrite existing entries therefore you must periodically clear the BMC system event log When you are troubleshooting an error be sure to clear the BMC system event log so that you can find current errors more easily High Precision Event Timer Select this choice to enable or disable the high precision event timer HPET function Event Error Logs Select this choice to view or clear error logs System Event Error Log Select this choice to view the complete log of POST error messages Use the arrow keys to move among pages in the log Run the diagnostic programs to get more information about error codes that occur See the Problem Determination and Service Guide on the IBM System x Documentation CD for instructions
74. r Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A Laser de Classe 1 Safety ix X Statement 4 A gt 18 kg 39 7 Ib gt 32 kg 70 5 Ib 2 55 kg 121 2 Ib CAUTION Use safe practices when lifting Statement 5 AA CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 2 7 mp am Dep m IBM System x3250 M2 Types 4190 and 4194 User s Guide Statement 8 AA CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement 26 A CAUTION Do not place any object on top of rack mounted devices This server is suitable for use on an IT power distribution system whose maximum phase to phase voltage is 240 V under any distribution fault condition Safety Xi Xii IBM System x3250 M2 Types 4190 and 4194 User s Guide Chapter 1 The System x3250 M2 Types 4190 and 4194 The IBM System x3250 M2 Type 4190 or 419
75. rating system if your operating system supports this feature After an orderly shutdown of the operating system the server will be turned off automatically You can press the power control button to start an orderly shutdown of the operating system and turn off the server if your operating system supports this feature If the operating system stops functioning you can press and hold the power control button for more than 4 seconds to turn off the server If an optional Remote Supervisor Adapter II SlimLine is installed in the server the server can be turned off from the Remote Supervisor Adapter Il SlimLine user interface The integrated systems management processor mini BMC can turn off the server as an automatic response to a critical system failure You can turn off the server through a request from the service processor Chapter 1 The System x3250 M2 Types 4190 and 4194 11 12 IBM System x3250 M2 Types 4190 and 4194 User s Guide Chapter 2 Installing optional devices This chapter provides detailed instructions for installing optional hardware devices in the server Server components The following illustrations show the major components in the server The illustrations in this document might differ slightly from your hardware 3 5 inch models Riser card Assembly Heat exchanger assembly Heat exchanger _ SAS SATA controller retention module gt some models System board
76. ration Setup Utility program is part of the basic input output system BIOS Use it to configure serial port assignments change interrupt request IRQ settings change the startup device sequence set the date_and time and set passwords For information about using this program see Using the Configuration Setup Utility program on page 44 LSI Logic Configuration Utility program Use the LSI Logic Configuration Utility program to configure devices that are attached to the SAS SATA controller For information about using this program see Using the LSI Logic Configuration Utility program on page 51 Important If the server is a simple swap SATA model that contains a SATA RAID back plate you can use the LSI Logic Configuration Utility program to configure the simple swap SATA hard disk drives The following table lists the different server configurations and the applications that are available for configuring and managing RAID arrays Table 4 Configuration and management applications for RAID arrays Server configuration RAID array configuration before operating system is installed RAID array management after operating system is installed Integrated SATA and no SAS controller card installed None None SAS SATA controller card LSI 1064 installed LSI Logic Configuration Utility Ctrl C during server startup ServerGuide MegaRAID Storage Manager ServeRAID MR10i adapter installed 2 5 inch
77. rector extensions xpress html Additional information http publib boulder ibm com infocenter toolsctr V1r0 index jsp Server controls LEDs and power Front view This section describes the controls and light emitting diodes LEDs and how to turn the server on and off Note The illustrations in this document show the 3 5 inch hard disk drive models unless specifically indicated otherwise The following illustration shows the controls light emitting diodes LEDs and connectors on the front of the server Hard disk drive activity LED Locator LED Reset button System error LED Power control button Us connector Power on LED qp aa je USB 2 connector Bo due s C 1 Ne CD eject button CD drive activity LED Power on LED When this LED is lit and not flashing it indicates that the server is turned on When this LED is flashing it indicates that the server is turned off and still connected to an ac power source When this LED is off it indicates that ac power is not present or the power supply or the LED itself has failed ae R OO Note If this LED is off it does not mean that there is no electrical power in the server The LED might be burned out To remove all electrical power from the server you must disconnect the power cord from the electrical outlet Power control button Press this button to turn the server on an
78. removed might damage server components Installing an adapter The following notes describe the types of adapters that the server supports and other information that you must consider when you install an adapter Locate the documentation that comes with the adapter and follow those instructions in addition to the instructions in this section If you have to change switch settings or jumper settings on the adapter follow the instructions that come with the adapter The adapter slots are on the riser card assembly You must first remove the riser card assembly to access the adapter slots The two PCI Express slots on the riser card assembly support PCI Express x8 1 0a adapters You can install one full height three quarter length adapter in expansion slot 1 and one low profile half length adapter in expansion slot 2 Note When the optional Remote Supervisor Adapter II SlimLine is installed in the server you can install only a half length adapter in expansion slot 1 If you have installed an optional PCI X riser card assembly in the server you can install a full height three quarter length PCI X 64 133 MHz adapter in the PCI X slot on the riser card assembly Note When the optional Remote Supervisor Adapter II SlimLine is installed in the server you can install only a half length adapter in the PCI X slot An optional Remote Supervisor Adapter II SlimLine can be installed only in the dedicated connector on the system board see Syst
79. ry Do not leave the device where others can handle and damage it While the device is still in its static protective package touch it to an unpainted metal part of the server for at least 2 seconds This drains static electricity from the package and from your body Remove the device from its package and install it directly into the server without setting down the device If it is necessary to set down the device put it back into its static protective package Do not place the device on the server cover or on a metal surface Take additional care when you handle devices during cold weather Heating reduces indoor humidity and increases static electricity Removing the cover To remove the cover complete the following steps 1 Read the safety information that begins on page v and Installation guidelines 22 IBM System x3250 M2 Types 4190 and 4194 User s Guide 2 Turn off the server and all attached devices see Turning off the server on page 19 3 Disconnect all external cables and power cords 4 Remove the server from the rack and place it on a flat static protective surface Cover release button 5 Press the cover release button 6 Slide the cover back approximately 1 27 cm 0 5 inches then lift it off the server Attention For proper cooling and airflow replace the cover before you turn on the server Operating the server for extended periods of time more than 30 minutes with the cover
80. s statement The product is not suitable for use with visual display work place devices according to clause 2 of the German Ordinance for Work with Visual Display Units Das Produkt ist nicht fur den Einsatz an Bildschirmarbeitsplatzen im Sinne 2 der Bildschirmarbeitsverordnung geeignet Electronic emission notices Federal Communications Commission FCC statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of
81. sors can run paravirtualization Memory Minimum Two 512 MB DIMMs Maximum 8 GB Type PC2 5300 667 MHz ECC DDR II unbuffered SDRAM DIMMs Slots Four dual inline Supports 512 MB 1 GB and 2 GB DIMMs Drives Ultrabay Enhanced CD or CD DVD Expansion bays One of the following configurations Two 3 5 inch slim high bays for hard disk drives Hot swap models Supports maximum of two serial attached SCSI SAS drives or two serial ATA SATA drives Simple swap models Supports maximum of two SATA drives Four 2 5 inch small form factor SFF hot swap bays for hard disk drives Supports a maximum of four 2 5 inch SAS drives Expansion slots Two PCI Express x8 slots one low profile and one 3 4 length full height Low profile slot supports x4 electrical Video controller ATI ES1000 video on system board 16 MB DDR II video memory Power supply 351 watt 110 or 220 V ac auto sensing Size Height 43 mm 1 75 inches 1 U Depth 559 mm 22 inches Width 440 mm 17 32 inches Maximum weight 12 7 kg 28 Ib depending on your configuration Integrated functions Two Broadcom NetXtreme GB Ethernet controllers on the system board with Wake on LAN support Serial port Four USB ports two on front and two on rear of server Systems management port if an optional Remote Supervisor Adapter II SlimLine is installed Hard disk controllers Serial
82. stem board switch or jumper block that is not shown in this document Administrator password If an administrator password is set you must type the administrator password for access to the full Configuration Setup Utility menu You can use any combination of up to seven characters A Z a z and 0 9 for the password If you forget the administrator password you can reset it after you change the position of the clear CMOS jumper See Resetting passwords for additional information Resetting passwords If you forget the power on password or administrator password you can move the clear CMOS jumper block on the system board to pins 2 and 3 to clear CMOS memory and bypass the power on or administrator password check The jumper location is shown in the following illustration Chapter 3 Configuring the server 49 m tJ WIL B 1 ul pem F re Pn SAS SATA controller DIMM 3 Slot card g e Clear CMOS jumper To clear CMOS and reset the passwords complete the following steps Note All configuration settings will be cleared by this action
83. stration identifies the pins on a jumper and shows the location of pin 1 O QO Pin 1 mark C 1 Table 2 Switch and jumper settings Component Settings Clear CMOS jumper JP3 Pins 1 and 2 Keep CMOS data default Pins 2 and 3 Clear the CMOS data which clears the power on password and administrator password Boot block jumper JP4 Pins 1 and 2 Normal default Pins 2 and 3 Boot from boot block 16 IBM System x3250 M2 Types 4190 and 4194 User s Guide System board external connectors The following illustration shows the external connectors on the system board Serial connector Video connector Ethernet 2 connector Ethernet 1 connector USB 4 connector USB 3 connector ra a Systems ors I TI B ww IR management connector B m ES Ie Lx E TT SAS SATA controller card a E DIMM 2 Slot H DIMM 3 Slot E DIMM 4 Slot lle EI 7 OG Chapter 2 Installing optional devices 17 System board LEDs The following illustration shows the light emitting diodes LEDs on the system 18
84. t after you restart the server power off the server then turn the server on again The baseboard management controller also provides the command line interface IPMI Shell remote server management capabilities through the Avocent SMBridge management utility program The command line interface provides direct access to server management functions through the IPMI 2 0 protocol Use the command line interface to issue commands to control the server power view system information and identify the server You can also save one or more commands as a text file and run the file as a script Installing the SMBridge management utility program 52 To install the SMBridge management utility program on a server running a Windows operating system complete the following steps 1 Go to http www ibm com systems support download the utility program and create the BMC Management Utility CD 2 Insert the BMC Management Utility CD into the drive The InstallShield wizard starts and a window similar to that shown in the following illustration opens InstallShield Wizard E xi Welcome to the InstallShield Wizard for OSA SMBridge The InstallShield Wizard will install OSA SMBridge on your computer To continue click Next 3 Follow the prompts to complete the installation IBM System x3250 M2 Types 4190 and 4194 User s Guide The installation program prompts you for a TCP IP port number and an IP address Specify an IP
85. t controller utility programs 53 command line interface 54 utility program baseboard management 52 Configuration Setup 44 LSI Logic Configuration Utility program 51 SAS configuration 51 SMBridge management 52 V video connector 9 video controller 4 W Web site ServerGuide 42 weight 4 Index 67 68 IBM System x3250 M2 Types 4190 and 4194 User s Guide Part Number 44R5195 Printed in USA 1P P N 44R5195
86. ter firmly into the expansion slot Chapter 2 Installing optional devices 25 26 10 qi 12 13 Expansion slot Adapter bracket bracket Tab Adapter Important Make sure that the U shaped opening in the metal adapter bracket engages the tab on the expansion slot bracket Follow the cabling instructions if any that come with the adapter Carefully align the riser card assembly with the guides on the rear of the server and with the riser card connectors on the system board then press down on the assembly Make sure that the riser card assembly is fully seated in the riser card connector on the system board Power cable PCI X slot If the riser card assembly is an optional PCI X riser card assembly in the server reconnect the riser card power cable to the riser card assembly If you are installing a ServeRAID MR10i controller 2 5 inch drive models only complete the following steps a Disconnect the existing SAS SATA controller signal cable from the hard disk drive backplane and from the controller then remove the cable from the server b Route the ServeRAID MR10i signal cable as shown in the following illustration and connect it to the hard disk drive backplane IBM System x3250 M2 Types 4190 and 4194 User s Guide VW I SSE re I VS ma J8 ML MN ServeRAID controller i l a a M im TE c c JL Fil Bd CE E l va Tol Hard disc dri
87. the Configuration Setup Utility program To start the Configuration Setup Utility program complete the following steps 1 2 3 Turn on the server When the prompt Press F1 for Configuration Setup is displayed press F1 If you have set both a power on password and an administrator password you must type the administrator password to access the full Configuration Setup Utility menu If you do not type the administrator password a limited Configuration Setup Utility menu is available Select settings to view or change Configuration Setup Utility menu choices The following choices are on the Configuration Setup Utility main menu Depending on the version of the BIOS code some menu choices might differ slightly from these descriptions 44 System Summary Select this choice to view configuration information including the type speed and cache size of the microprocessor and the amount of installed memory When you make configuration changes through other choices in the Configuration Setup Utility program the changes are reflected in the system summary you cannot change settings directly in the system summary This choice is on the full and limited Configuration Setup Utility menu System Information Select this choice to view information about the server such as the machine type and model of the server the serial number the system UUID the system board identifier and the revision level or issue date of the BIOS code
88. the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Industry Canada Class A emission compliance statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformit la r glementation d Industrie Canada Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada Australia and New Zealand Class A statement Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures United Kingdom telecommunications safety requirement Notice to Customers This apparatus is approved under approval number NS G 1234 J 100003 for indirect connection to public telecommunication systems in the United Kingdom 62 IBM System x3250 M2 Types 4190 and 4194 User s Guide European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product including the fitting of non IBM option cards This product
89. to disconnect it from the system board then lift it out of the server You can press the middle of the mounting bracket toward the back of the server to spread the retention latches See the documentation that comes with the Remote Supervisor Adapter II SlimLine for information about installing the firmware and configuring the adapter Create a backup copy of the configuration so that if you have to replace the adapter in the future you can restore the configuration If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 38 Installing a hard disk drive Locate the documentation that comes with the hard disk drive and follow those instructions in addition to the instructions in this chapter Attention To avoid damage to the hard disk drive connectors make sure that the cover is in place and fully closed whenever you install or remove a hard disk drive Chapter 2 Installing optional devices 29 Installing a simple swap Serial ATA hard disk drive 30 Attention Simple swap hard disk drives are not hot swappable Disconnect all power from the server before you remove or install a simple swap hard disk drive To install a simple swap Serial ATA hard disk drive complete the following steps Note If you have only one hard disk drive install it in the left drive bay SATA hard disk drive back plate Hard disk drive assembly Filler panel Attention To avoid
90. ts in this document before you perform the procedures Read any additional safety information that comes with the server or optional device before you install the device IBM System x3250 M2 Types 4190 and 4194 User s Guide Statement 1 AA DANGER Electrical current from power telephone and communication cables is hazardous To avoid a shock hazard Do not connect or disconnect any cables or perform installation maintenance or reconfiguration of this product during an electrical storm Connect all power cords to a properly wired and grounded electrical outlet Connect to properly wired outlets any equipment that will be attached to this product When possible use one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire water or structural damage Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation and configuration procedures Connect and disconnect cables as described in the following table when installing moving or opening covers on this product or attached devices To Connect To Disconnect 1 Turn everything OFF 1 Turn everything OFF 2 First attach all cables to devices 2 First remove power cords from outlet 3 Attach signal cables to connectors 3 Remove signal cables from connectors 4 Attach power
91. untry View the overview to learn about ServerGuide features View the readme file to review installation tips for your operating system and adapter e Start the operating system installation You will need your operating system CD Typical operating system installation The ServerGuide program can reduce the time it takes to install an operating system It provides the device drivers that are required for your hardware and for the operating system that you are installing This section describes a typical ServerGuide operating system installation Note Features and functions can vary slightly with different versions of the ServerGuide program 1 After you have completed the setup process the operating system installation program starts You will need your operating system CD to complete the installation 2 The ServerGuide program stores information about the server model service processor hard disk drive controllers and network adapters Then the program checks the CD for newer device drivers This information is stored and then passed to the operating system installation program 3 The ServerGuide program presents operating system partition options that are based on your operating system selection and the installed hard disk drives 4 The ServerGuide program prompts you to insert your operating system CD and restart the server At this point the installation program for the operating system takes control to complete the
92. update The firmware update utility program updates the baseboard management controller firmware or SDR FRU data only and does not affect any device drivers Important To ensure proper server operation be sure to update the server baseboard management controller firmware before you update the BIOS code To download the program complete the following steps Note Changes are made periodically to the IBM Web site The actual procedure might vary slightly from what is described in this document 1 Go to http www ibm com systems support 2 Under Product support click System x 3 Under Popular links click Software and device drivers 4 Click IBM System x3250 M2 to display the matrix of downloadable files for the server 5 From the BMC software choice click the link for the applicable package and download the package To update the firmware run the executable program in the package Follow the instructions that come with the package Using the SMBridge management utility program Use the SMBridge management utility program to remotely manage and configure a network The utility program provides the CLI command line interface remote management capabilities Use CLI mode to remotely perform power management and system identification control functions over a LAN interface from a command line interface Use CLI mode also to remotely view the BMC system event log Use the following commands in CLI mode connect Connect t
93. upport for systems management industry standards Integration into leading workgroup and enterprise systems management environments Ease of use training and setup IBM Director also provides an extensible platform that supports advanced server tools that are designed to reduce the total cost of managing and supporting networked systems By deploying IBM Director you can achieve reductions in ownership costs through the following benefits Reduced downtime Increased productivity of IT personnel and users Reduced service and support costs For more information about IBM Director see the documentation on the BM Director CD that comes with the server the IBM Director Information Center at publib boulder iobm com infocenter eserver v1 r2 topic diricinfo_all diricinfoparent html and the IBM System x and xSeries Systems Management Web page at http www ibm com systems management which presents an overview of IBM Systems Management and IBM Director Chapter 1 The System x3250 M2 Types 4190 and 4194 7 The UpdateXpress program The UpdateXpress program is available for most System x servers and optional devices It detects supported and installed device drivers and firmware in the server and installs available updates You can download the UpdateXpress program from the Web at no additional cost or you can purchase it on a CD To download the http www ibm com servers eserver xseries systems management ibm di
94. ur server The ServerGuide program detects the server model and optional hardware devices that are installed and uses that information during setup to configure the hardware The ServerGuide program simplifies operating system installations by providing updated device drivers and in some cases installing them automatically If a later version of the ServerGuide program is available you can download a free image of the ServerGuide Setup and Installation CD or purchase the CD from the ServerGuide fulfillment Web site at http www ibm com systems management serverguide sub html To download the free image click IBM Service and Support Site The ServerGuide program has the following features An easy to use interface Diskette free setup and configuration programs that are based on detected hardware Device drivers that are provided for the server model and detected hardware Operating system partition size and file system type that are selectable during setup ServerGuide features 42 Features and functions can vary slightly with different versions of the ServerGuide program To learn more about the version that you have start the ServerGuide Setup and Installation CD and view the online overview Not all features are supported on all server models The ServerGuide program requires a supported IBM server with an enabled startable bootable CD drive In addition to the ServerGuide Setup and Installation CD you must have
95. user that authority Power on password If a power on password is set when you turn on the server the system startup will not be completed until you type the power on password You can use any combination of up to seven characters A Z a z and 0 9 for the password 48 IBM System x3250 M2 Types 4190 and 4194 User s Guide If a power on password is set you can enable the Unattended Start mode in which the keyboard and mouse remain locked but the operating system can start You can unlock the keyboard and mouse by typing the power on password If you forget the power on password you can regain access to the server in any of the following ways f an administrator password is set type the administrator password at the password prompt see Administrator password Start the Configuration Setup Utility program and reset the power on password Remove the battery from the server and then reinstall it For instructions for removing the battery see the Problem Determination and Service Guide on the IBM System x Documentation CD Change the position of the clear CMOS jumper on the system board to bypass the power on password check See Resetting passwords for additional information Attention Before you change any switch settings or move any jumpers turn off the server then disconnect all power cords and external cables See the safety information that begins on pageM Do not change settings or move jumpers on any sy
96. vebackplane A J9 e Ifo Ed E o o T T lol V7 J E If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 38 Installing a Remote Supervisor Adapter Il SlimLine Install an optional Remote Supervisor Adapter II SlimLine in the Remote Supervisor Adapter Il SlimLine connector on the system board See the illustration in System board optional device connectors on page 19 for the location of the connector After the Remote Supervisor Adapter II SlimLine is installed the systems management port on the rear of the server is active Important When the optional Remote Supervisor Adapter II SlimLine is installed in the server you can install only a half length adapter in expansion slot 1 Notes 1 When you start the server for the first time after you install a Remote Supervisor
97. zardous procedure step or situation Danger These statements indicate situations that can be potentially lethal or extremely hazardous to you A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation IBM System x3250 M2 Types 4190 and 4194 User s Guide Features and specifications The following information is a summary of the features and specifications of the server Depending on the server model some features might not be available or some specifications might not apply Racks are marked in vertical increments of 4 45 cm 1 75 inches Each increment is referred to as a unit or U A 1 U high device is 1 75 inches tall Chapter 1 The System x3250 M2 Types 4190 and 4194 3 Table 1 Features and specifications Microprocessor One Intel LGA 775 single core dual core or quad core depending on the server model Single core Celeron 440 or later Dual core Core 2 Duo E4600 or Xeon E3110 or later Quad core Xeon 3300 series See http www ibm com servers eserver serverproven compat us for a list of supported microprocessors Notes 1 Use the Configuration Setup Utility program to determine the size of the L2 cache type and speed of the microprocessor and speed of the front side bus 2 Intel Virtualization Technology VT is not available on the Celeron 440 or the Core 2 Duo E4600 however these microproces