Husky BDH-550 User's Manual

image

Contents

1. QUICK SET UP GUIDE BUCKETLESS DEHUMIDIFIERS LOCATION Allow at least 12 of space on all sides of the unit for good air circulation For best results be sure to have all doors and windows closed in the area it is located NOTE Keep the unit away from any sources of dust or dirt such as woodworking equipment HOSE SET UP Installing the Drainage Hose The drainage hose can be put out into any suitable area where water can be emptied The hose can be run outside through a window ina sink or in a drain Attention should be given to the flow of the drained water Be sure it flows away from buildings and other objects that could be damaged CAUTION The drainage hose MUST NOT be installed more than ten 10 feet above the floor on which the unit is standing Disposing of the collected water 1 Continuous draining using the pump Choose a safe location to drain the water that flows away from buildings and other objects that could be damaged Our specially designed vertical pump allows water removal of up to 10 feet in height making it possible to discharge the water out a window into a drain pipe or in a sink NOTE Make sure the pump light is on when using this option Failure to have the unit in pump mode will cause the unit to fill up and shut off Please refer to page 5 in your owner s manual if you would like to drain the dehumidifier directly into a drain without the use of the pump POWER Press power button to start C
2. c Ales TIMER PUMP SET HUMIDITY SPEED low SET HUMIDITY The set humidity function will allow you to set the desired level of humidity you would like for the room To set it press the Set Humidity button and use the or button to set the percentage The unit will turn on automatically when the room humidity is higher than the selected humidity For the best results the humidity level should be reduced gradually Start at the highest setting Reduce it by 5 until the compressor turns on Allow the unit to run at this level until it maintains this level of humidity then continue to reduce it gradually until it is between 30 and 50 depending on your level of comfort TIMER gt DEFROST PUMP FuLL After setting the desired humidity the unit will run automatically maintaining the desired humidity The Relative Humidity may be set from RH 30 to RH 80 The operational temperature for this unit is between 40 F and 95 F If the temperature of the room falls below 40 F the unit will stop This function protects the compressor and is normal NOTE The selected humidity may vary by 5 or SET FAN SPEED Press Speed button to change ventilation speed Use the High setting for maximum energy efficiency and the Low setting if you prefer more quiet operation WATER FULL LIGHT Full Light will illuminate if water is restricted from exiting the unit CAUTION Do not move the dehumidi
3. fier when it is running

Download Pdf Manuals

image

Related Search

Related Contents

Baracoda ZODIAC 1500 User's Manual  bilan de l`opération - Entraigues sur La Sorgue  M2A-VM HDMI  ASSMANN Electronic AK 103 5M printer cable    STR-DA50ES    

Copyright © All rights reserved.
Failed to retrieve file