Hunter 81003 User's Manual

image

Contents

1. Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan If any part of your Hunter bath exhaust fan except for glass fixtures and light bulbs fails at any time within one year after the date of sale to you due to a defect in material or workmanship we will repair or at our option replace the defective part free of charge for parts and labor performed at our nearest service center or at our Service Department in Memphis Tennessee After this one year period you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or workmanship labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service Department in Memphis Tennessee If no replacement part can be provided we will at our option either refund the actual purchase price of your bath exhaust fan or provide a replacement free of charge After this five year period you will be responsible for all parts and labor costs for repairs on all parts of the bath exhaust fan IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHAN
2. 81003 Ashbury Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 41939 01 1 11 2006 AW ARN N G TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY OBSERVE THE FOLLOWING 1 Use this unit only in a manner intended by the manufacturer such as those published by the National Fire Prevention If you have questions contact the manufacturer at the phone Association NFPA and the American Society for Heating number or address listed in the warranty Refrigeration and Air Conditioning Engineers ASHRAE and 2 Before installing servicing or cleaning the unit os ode NON LES disconnect the power by turning off the circuit breakers to 5 When cutting or drilling into wall s or ceiling do not the outlet box and associated wall switch location If you damage electrical wiring or other hidden utilities cannot lock the circuit breakers in the off position securely 6 Ducted fans must always be vented to the outdoors Keep attach a prominent warning device such as a tag to the ducting as short and as straight as possible service panel a 7 Acceptable for use over a bathtub or shower when 3 Installation work and electrical wiring must be done by connected to a GFCI protected branch circuit qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 9 Never place a switch where it can be reached from a tub or shower 8 Install fan at least 5 feet 1 52 m
3. Protecci n contra Incendios NFPA la Asociaci n de Ingenieros Americanos en Calefacci n y Aire acondicionado ASHRAE y los c digos locales 5 Al cortar o taladrar en paredes 0 techo no da e el cableado el ctrico u otros servicios no visibles 6 Los ventiladores canalizados siempre deben descargar al aire libre Mantenga los ductos tan cortos y rectos como sea posible 7 Aceptable para uso sobre una ba era o ducha si se conecta en un circuito derivado protegido por un interruptor autom tico de falla a tierra GFCI 8 Instale el ventilador por lo menos a 5 pies 1 52 m por encima del piso 9 Nunca coloque un interruptor donde pueda ser alcanzado desde una tina o una ducha 10 Esta unidad debe ponerse a tierra 11 Para conexiones de alimentacion use alambres adecuados al menos para 90 C 194 F A ADVERTENCIA DESCONECTE LA ALIMENTACI N EL CTRICA Y CIERRE EL PANEL DE SERVICIO ANTES DE DAR MANTENIMIENTO A LA UNIDAD MANTENIMIENTO PREVENTIVO Un ventilador limpio proporciona mejor servicio Desconecte la alimentaci n y limpie el ventilador como se indica a continuaci n PARA LIMPIAR LA REJILLA Use un detergente suave como l quido para lavado de platos y un pa o suave NO emplee pa os abrasivos almohadillas de lana de acero ni polvos para fregar PARA LIMPIAR EL CONJUNTO DEL VENTILADOR Desconecte el cord n del motor de la toma de corriente Para retirar la placa del motor encuentr
4. Si alguna pieza de su Extractor de aire para bafio Hunter con excepci n de las l mparas de vidrio y las bombillas falla en cualquier momento dentro de un afio despu s de la fecha de compra debido a una falla de material o mano de obra repararemos o a nuestra elecci n reemplazaremos la pieza defectuosa sin costo de partes y mano de obra realizada en nuestro centro de reparaciones m s cercano o en nuestro Departamento de servicio en Memphis Tennessee Despu s de este per odo de un a io usted ser responsable de todos los costos de partes y mano de obra para reparaciones del Extractor de aire para ba o con excepci n de reparaciones del motor como se estipula a continuaci n Si el motor de su Extractor de aire para bafio Hunter falla en cualquier momento dentro de cinco afios despu s de la fecha de compra debido a una falla de material o mano de obra la mano de obra y los materiales para reparar la falla ser n proporcionados sin costo en nuestro centro de reparaciones m s cercano o en nuestro Departamento de servicio en Memphis Tennessee Si no puede pro porcionarse alguna parte de reemplazo a nuestra elecci n le reembolsaremos el precio de compra real de su Extractor de aire para ba o o le proporcionamos uno de reemplazo sin costo Despu s de este per odo de cinco a os usted ser responsable de todos los costos de partes y mano de obra para reparaciones de cualquier componente del Extractor de aire para ba o SI EL USUARIO 0
5. above the floor 4 Sufficient air is needed for proper combustion and exhaust ing of gasses through the flue chimney of fuel burning 10 This unit must be grounded equipment to prevent backdrafting Follow the heating DM 11 For ly connection ir itable for at least equipment manufacturer s guideline and safety standards E consen ee vires UI tor al leas 90 C 194 F ACAUTION AWARNING 1 For general ventilating use only Do not use for ventilat ing hazardous or explosive materials DISCONNECT 2 To avoid motor bearing damage and noisy unbalanced ELECTHIC impellers keep drywall spray construction dust etc GI awe UE POWER SUPPLY 3 DO NOT install this product in a wall This product is AND LOCK OUT designed for installation in ceilings up to a 12 12 pitch SERVICE PANEL 45 degrees Ductwork must point upward B E FORE 4 Please read specification label on product for further information and requirements SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service Disconnect the power supply and clean the fan as listed below TO CLEAN GRILLE Use a mild detergent such as dishwashing liquid and a soft cloth DO NOT use abrasive cloths steel wool pads or scouring powders TO CLEAN FAN ASSEMBLY Unplug motor cord from receptacle To remove motor plate find the single tab on the motor plate located next to the receptacle Push up rear motor plate tab while pushing out on the side of the hous
6. dentro de la caja o debajo de la placa de cubierta del cableado 41939 02 1 11 2006 Conecte el mazo de cables NO PERMITA QUE EL MOTOR Vuelva a instalar el motor introduciendo las pesta as y CUELGUE DEL MAZO DE CABLES levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor y el alojamiento Vaya al paso en la p gina 10 para fijar la rejilla Pruebe el motor Si el motor no funciona verifique la conexi n del enchufe 41939 02 1 11 2006 Construcci n existente Retire el ventilador existente y aseg rese que la abertura Mueva el alojamiento a su posici n encima del techo sea suficientemente grande para acomodar el alojamiento del motor nuevo 7 1 4 x 7 3 4 Tienda los cables a trav s del alivio de tension Para Conecte el ducto existente con el conector de ducto conexiones de alimentaci n use alambres adecuados al Aplique cinta a las uniones Si el ducto no se ajusta firme menos para 90 C 194 F mente puede ser necesario comprar un adaptador Instale el alojamiento a nivel con la plancha de yeso y aseg relo apretando los tornillos precargados en la vida 41939 02 1 11 2006 Tierra ES Verde e Blanco Cobre desnudo Interruptor negro principal 1 AC X Blanco Interruptor negro 2 AC Conecte los alambres como se muestra Instale la placa de cu
7. into position above the ceiling ing is large enough to accommodate the new motor hous ing 7 1 4 x 7 3 4 Route wires through the strain relief For supply connection Attach existing ducting to duct connector Tape joints use wires suitable for at least 90 C 194 F If ducting does not fit securely an adapter may need to be purchased Install the housing flush with the sheetrock and secure by tightening the pre loaded screws into the joist 41939 01 1 11 2006 Ground Green Bare Copper Black Main Switch 1 AC In XZ E Black Switch 2 AC In Connect wires as shown Install the wiring cover plate Connect wiring harness DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS Reinstall the motor by inserting the tabs and pushing up Secure the motor by tightening the 2 screws into position Make sure the wires are not pinched between the motor and the housing 41939 01 1 11 2006 B22 ON EE OFF Turn on the power source Test the motor If the motor does not run check the plug connection Go to step O on page 10 to attach grille Attaching the Grille Remove the thumbscrews Remove glass dome 10 41939 01 1 11 2006 Connect wiring harness DO NOT ALLOW THE FIXTURE TO Align posts 1 2 and 3 stamped into motor housing with HANG FROM THE WIRING HARNESS posts 1
8. 1 11 2006 Retire las cubiertas de las puntas de tornillo precargadas Retire las puntas de tornillo precargadas hasta que est n a nivel con el lado del alojamiento Retire el tornillo de la cubierta del cableado Retire la cubierta del cableado 41939 02 1 11 2006 Inserte el alivio de tensi n no se incluye en la caja y suj Expulse el primer tap n met lico de acceso del cableado telo firmemente con una arandela Utilice el segundo si es necesario Escoja la opci n de instalaci n Para construcci n nueva vaya al paso A11 p gina 5 Para construcci n existente vaya al paso B11 p gina 8 Construcci n nueva Ubique la correcta marca de profundidad en el borde infe Instale los tornillos precargados en la viga o el marco rior de la viga seg n el espesor de su plancha de yeso 41939 02 1 11 2006 Tienda los cables a trav s del alivio de tension Para conexiones de alimentaci n use alambres adecuados al menos para 90 C 194 F Tierra PO a Verde PNE S Cobre desnudo SS Interruptor negro principal 1 AC MD Blanco Interruptor negro 2 AC Conecte los alambres como se muestra IA NS Conecte un ducto de 4 y ventile hacia el exterior Aplique cinta a las uniones Si el ducto no se ajusta firmemente puede ser necesario comprar un adaptado Instale la placa de cubierta del cableado Aseg rese que todas las conexiones de cableado est n
9. 2 and 3 stamped into light fixture Slide light fixture over posts mj ALIS 590090000065 i Ww i a I e nj 1 M se TL 1 ser on LI s LI 1 5 E j x T a 1 Attach thumbscrews Install 2 Max 60 Watt A15 bulbs Not Included WARNING To reduce the risk of electrical shock all 4 thumbscrews MUST be properly installed Align glass dome and push up Screw glass dome into position 41939 01 1 11 2006 11 12 Trouble Shooting Problem Fan does not come on Solution e Hunter Fan Bath Ventilators are extremely quiet To confirm that the fan is running place your hand near the vents to feel the air movement Turn power on replace fuse or reset breaker Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Light does not come on Solution Replace the light bulb with a new bulb Turn power on replace fuse or reset breaker Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution e Check and tighten all fasteners e Check the glass to make sure it is secure Check the flapper to make sure it moves freely If you need parts or service assistance please call 888 830 1326 or visit us at our WEB site at http www hunterfan com 41939 01 1 11 2006 Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY
10. COMPRADOR ORIGINAL DEJA DE POSEER EL EXTRACTOR DE AIRE ESTA GARANT A Y CUALQUIER GARANT A IMPLICITA QUE PERMANEZCA EN EFECTO INCLUYENDO PERO SIN LIMITARSE A TODA GARANTIA IMPLICITA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROP SITO PARTICULAR QUEDA ANULADA NO SE OFRECE NINGUNA GARANT A EXPRESA O IMPLICITA INCLUY ENDO CUALQUIER GARANT A DE COMERCIABILIDAD O IDONEIDAD PARA UN PROP SITO PARTICULAR PARA LAS LAMPARAS DE VIDRIO 0 LAS BOMBILLAS 0 EL ACABADO EN CUALQUIER PARTE MET LICA DEL EXTRACTOR DE AIRE PARA BANO ESTA GARANT A SUSTITUYE A TODAS LAS OTRAS GARANT AS EXPRESAS LA DURACI N DE TODA GARANT A IMPL CITA INCLUYENDO PERO SIN LIMITARSE A CUALQUIER GARANTIA IMPLICITA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPOSITO PARTICULAR CON RESPECTO DE CUALQUIER MOTOR DE EXTRACTOR DE AIRE PARA BANO HUNTER U OTRA PARTE DEL VENTILADOR EST EXPRESAMENTE LIMITADA AL PERIODO DE LA GARANTIA EXPRESA ESTABLECIDA ANTERIORMENTE PARA DICHOS MOTORES U OTRAS PARTES Esta garant a es nula si su Extractor de aire para ba o no se adquiere e instala en los EE UU Esta garant a excluye y no cubre defectos aver as o fallas del Extractor de aire para ba o Hunter que fueran ocasionados por reparaciones por parte de personas no autorizadas por nosotros por el uso de piezas o accesorios no autorizados por nosotros por mal uso modificaciones o dafios al Extractor de aire para ba o Hunter mientras est en su posesi n o por un empleo no razonable incluyendo l
11. Impreso en China 41939 02 1 11 2006
12. TABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS This warranty is voided if your Hunter bath exhaust fan is not purchased and installed in the U S A This warranty excludes and does not cover defects malfunctions or failures of any Hunter bath exhaust fan which were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling improper installation modifications or damage to the Hunter bath exhaust fan while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance To obtain servicing contact the nearest Hunter authorized service center of the Hunter Fan Company Service Department 2500 Frisco Avenue Memphis Tennessee 38114 Please contact us before shipping your bath exhaust fan to us If we authorize you to ship it to us you will be responsible
13. a apagando los interruptores autom ticos que alimentan la caja de salida y al interruptor de pared respectivo Si no puede bloquear los interruptores autom ticos en la posici n de apagado fije firmemente una forma destacada de advertencia como una etiqueta de seguridad en el tablero de servicio 3 Los trabajos de instalaci n y cableado el ctrico deben ser realizados por personas calificadas de acuerdo con todos los c digos y las normas aplicables incluyendo los c digos y normas de construcci n contra incendio 4 Se necesita aire suficiente para una combusti n adecuada y para evacuar los gases por el tubo de la chimenea de equipo que quema combustible a fin de evitar el flujo inverso Siga las pautas del fabricante del equipo de calefacci n y las normas de seguridad como las de la Asociaci n Nacional de A PRECAUCI N S lo para uso de ventilaci n general No lo utilice para ventilar ambientes con materiales peligrosos o explosivos Para evitar da os a los rodamientos del motor e impulsores ruidosos o desbalanceados mantenga la unidad de potencia lejos de la aplicaci n de aerosol para paneles de yeso drywall polvo de la construcci n etc 3 NO instale este producto en una pared Este producto est dise ado para instalarse en techos con una inclinaci n de hasta 12 12 459 La red de ductos debe dirigirse hacia arriba 4 Vea m s informaci n y los requisitos en la etiqueta de especificaci n del producto
14. a falta de suministrar un razonable y necesario mantenimiento Para obtener servicio contacte con el centro de servicio autorizado Hunter o con nuestro Departamento de servicio de Hunter Fan Company en 2500 Frisco Avenue Memphis Tennessee 38114 Le agradeceremos que se ponga en contacto con nosotros antes de enviarnos su Extractor de aire para ba o Si le autorizamos a enviarlo usted ser responsable de todos los cargos de seguro y flete o de otras cargas del transporte a nuestra planta o centro de reparaciones Devolveremos su Extractor de aire para ba o Hunter con el flete prepagado Su Extractor de aire para ba o Hunter se debe embalar apropiadamente para evitar da os durante el tr nsito ya que no seremos responsables de dichos da os Al solicitar un servicio de garantia debe exhibir una prueba de su compra El comprador debe presentar el recibo de compra u otro documento que establezca la prueba de su compra EN NING N CASO HUNTER FAN COMPANY SER RESPONSABLE DE DA OS PERJUDICIALES O ACCESORIOS ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SOBRE LA DURACI N DE UNA GARANT A IMPL CITA O LA EXCLUSI N O LIMITACI N DE DANOS ACCESORIOS O PERJUDICIALES POR LO QUE LA LIMITACI N O EXCLUSIONES ANTES MENCIONADAS PUEDEN NO APLICARSE A USTED LA GARANT A LE DA DERECHOS LEGALES ESPEC FICOS PERO USTED TAMBI N PUEDE TENER OTROS DERECHOS QUE VAR AN DE ESTADO A ESTADO 41939 02 1 11 2006 13 2500 Frisco Avenue Memphis Tennessee 38114
15. bierta del cableado Conecte el mazo de cables NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES Vuelva a instalar el motor introduciendo las pesta as y Asegure el motor apretando los 2 tornillos levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor y el alojamiento 41939 02 1 11 2006 Encienda la fuente de alimentaci n Go to step Q on page 10 to attach grille Fijaci n de la rejilla Retire los tornillos de mano B22 EE OFF Pruebe el motor Si el motor no funciona verifique la conex i n del enchufe Retire le dome de verre 41939 02 1 11 2006 Conecte el mazo de cables NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES e ALIS 590090000065 i Ww i a I e nj 1 M se TL 1 ser on LI s LI 1 5 a LI 3 T T a 1 Instale los tornillos de mano ADVERTENCIA Para reducir el riesgo de descarga el ctrica los 4 tornillos de mano DEBEN instalarse apropiadamente Alinee los postes 1 2 y 3 estampados en la caja del mo tor con los postes 1 2 y 3 estampados en el artefacto de ilumunaci n Deslice la l mpara sobre los postes Instale 2 bombillas A 15 de 60 vatios como m ximo No incluidas Alinee el domo de vidrio y levante 41939 02 1 11 2006 Enrosque el dome vidrio en su posici n 11 12 Soluci n
16. de problemas Problema El ventilador no est operando Soluci n e Los ventiladores de ba o Hunter son muy silenciosos Para confirmar que el ventilador est funcionando coloque su mano cerca de los conductos de ventilaci n para sentir el movimiento del aire Encienda la alimentaci n el ctrica reemplace el fusible o restablezca el interruptor autom tico Verifique todas las conexiones de los enchufes para asegurarse que est n firmes Verifique el cableado para asegurarse que coincida con el diagrama de cableado Problema La luz no funciona Soluci n Reemplace la bombilla con una nueva Encienda la alimentaci n el ctrica reemplace el fusible o restablezca el interruptor autom tico Verifique todas las conexiones de los enchufes para asegurarse que est n firmes Verifique el cableado para asegurarse que coincida con el diagrama de cableado Problema El ventilador hace ruido Soluci n Verifique y apriete todos los pernos y tornillos Verifique la pantalla para asegurarse que est firme Verifique la v lvula de retenci n para asegurarse que se mueva con libertad Si necesita repuestos o servicio llame al 888 830 1326 o visite nuestro sitio web en http www hunterfan com 41939 02 1 11 2006 Hunter Fan Company Extractor de aire para bafio GARANTIA LIMITADA Hunter Fan Company establece la siguiente garant a limitada al usuario o comprador original de este Extractor de aire para bafio Hunter
17. e la pesta a en la placa ubicada junto a la toma de corriente Levante la pesta a posterior de la placa del motor mientras empuja hacia afuera en el lado del alojamiento o introduzca un destornillador en la ranura del alojamiento junto a la pesta a y gire el destornillador Suavemente aspire el ventilador el motor y el interior del alojamiento LAS PARTES MET LICAS EL CTRICAS NUNCA DEBEN SUMERGIRSE EN AGUA MANTENIMIENTO El motor est lubricado permanentemente y no necesita ser engrasado Si los rodamientos del motor hacen ruidos excesivos 0 inusuales reemplace el motor con el motor de servicio exacto Debe reemplazar el impulsor al mismo tiempo 41939 02 1 11 2006 Verifique todos los componentes Si est n da ados gt 95029 01 000 llame al 1 888 830 1326 para un reemplazo gt 75191 01 000 b 03242 07 133 b 95491 02 000 gt 74508 03 133 X2 p 96397 01 444 gt 75184 01 133 85812 03 000 X2 p X Nota Nota Debe estar instalado el gt 75733 01 444 manguito de alivio de tensi n del cable No incluido Incluido Herramientas necesarias no suministradas Tiempo estimado de ensamblaje entre 30 y 60 minutos Antes de la instalaci n NOTA Retire todo el material de embalaje antes de la instalaci n Apague la fuente de alimentaci n Afloje los tornillos 41939 02
18. for all insurance and freight or other transportation charges to our factory or service center We will return your Hunter bath exhaust fan freight prepaid Your Hunter bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present the sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE 41939 01 1 11 2006 13 2500 Frisco Avenue Memphis Tennessee 38114 Printed in China 41939 01 1 11 2006 Ventilador para ba o 81003 Ashbury con luz LEA y CONSERVE ESTAS INSTRUCCIONES 41939 02 1 11 2006 Ww Ww A S A LEN M NA M PARA REDUCIR EL RIESGO DE DESCARGA EL CTRICA O LESIONES OBSERVE LO SIGUIENTE 1 Utilice esta unidad s lo de la manera indicada por el fabricante Si tiene alguna pregunta contacte con el fabricante en el tel fono o la direcci n indicados en la garant a 2 Antes de instalar dar servicio o limpiar la unidad desco necte la alimentaci n el ctric
19. ing or insert a screwdriver into the slot in the housing next to tab and twist screwdriver Gently vacuum fan motor and interior of housing METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER MAINTENANCE The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor You should replace the impeller at the same time 41939 01 1 11 2006 Check all the parts If damaged call gt 95029 01 000 1 888 830 1326 for replacements gt 75191 01 000 gt 03242 07 133 b 95491 02 000 gt 74508 03 133 X2 D 96397 01 444 b 75184 01 133 d 85812 03 000 X2 gt Extra EC 75733 01 444 NOTE Strain relief cable connector must be installed Not Included Included Tools Needed Not supplied Estimated assembly time 30 to 60 minutes Before Installation NOTE Remove all packing materials before installation Turn off the power source Loosen screws 41939 01 1 11 2006 Remove the pre loaded screw tip covers Back out the pre loaded screw tips until flush with the side of the housing Remove the wiring cover screw Remove the wiring cover 41939 01 1 11 2006 Pop out the first wiring access slug Use second if needed Insert the strain relief not i
20. ncluded into the housing and secure with washer Choose Installation Option For New Construction go to step A11 page 5 For Existing Construction go to step B11 page 8 New Construction Position the correct depth mark at the bottom edge of the Screw pre loaded screws into joist or framing joist based on the thickness of your sheetrock 41939 01 1 11 2006 Route wires through the strain relief For supply connection use wires suitable for at least 90 C 194 F Bare Copper Fan Motor Black Main Switch 1 AC In Light O Black Light Black Switch 2 AC In Connect wires as shown Install the wiring cover plate Make sure all Connect 4 duct and vent to the outside Tape joints wiring connections are inside the box or under If ducting does not fit securely an adapter may need the wiring cover plate to be purchased 41939 01 1 11 2006 Connect wiring harness DO NOT ALLOW THE MOTOR TO Reinstall the motor by inserting the tabs and pushing up HANG FROM THE WIRING HARNESS into position Make sure the wires are not pinched between the motor and the housing Go to step on page 10 to attach grille Test the motor If the motor does not run check the plug 41939 01 1 11 2006 Existing Construction EXISTING FAN Remove an existing fan and check to make sure the open Move the housing