Home
Huawei AOLYNK S1505L User's Manual
Contents
1. Connected to carrier network e VoIP port Connected to IP phone e TV port Connected to IPTV set top box e PC port Connected to PC e EXP port Expansion port which can be used as the console port 1 1 Appearance I Front panel Figure 1 1 shows the LEDs on the front panel of the S1505L a power LED pairs of speed and Link Act LEDs with each pair corresponding to one Ethernet port Uplink YolIP TY EXP Speed Power S g O 5p G D O O LinkiAct Figure 1 1 Front panel 1 1 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 1 Product Overview Table 1 1 LED description te Label site desertion The S1505L is powered on Power Power The S1505L is powered off The port is operating at 100 Mbps Speed Speed OFF The port is operating at 10 Mbps or no Ethernet link is present An Ethernet link is established State Link Act OFF No Ethernet link is present Data is ee transmitted and or received on the ee Il Rear panel Figure 1 2 shows the rear panel of the S1505L On this panel there are five autosensing 10 100Base TX Ethernet ports one Reset button unavailable for the S1505L and one power jack Ore ale Figure 1 2 Rear panel 1 2 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 1 Product Overview 1 2 Features Table 1 2 Feature description Feature Description VLAN virtual IEEE 802 1 Q compliant VLAN local area Port based VLAN network 16 VLANs a
2. Advance Settings allows you to perform advanced configuration of VLAN including the selection between port based VLAN and 802 1Q based VLAN the settings of rate limit broadcast storm control and priority weight and so on Change Password allows you to modify the password tieta Language Help Advanced Settings Change Password Figure 3 5 Advanced menu items 3 6 User Manual Aolynk S 1505L Smart Ethernet Switch Chapter 3 Configuration e Language Language allows you to shift between English and Chinese File Advanced Chinese w English Figure 3 6 Language menu items e Help About provides you with the version and copyright information about the S1505L configuration program File Advanced Language ES e Figure 3 7 Help menu items 3 3 Quick Setup The following four steps guide you through the quick setup of the S1505L on the main configuration window 1 Click lt Connect gt and the program automatically searches for the COM port connected to the S1505L to make a connection with the S1505L Once connected is displayed you can configure the S1505L 2 Click lt Show Configuration gt to display the current configurations of the S1505L 3 To set VLAN type in a VLAN ID assigned by the carrier in the corresponding VLAN text box of each port according to the actual networking creating a VLAN which contains both this port and the Uplink port which is tagged by default 3 User Ma
3. Broadcast Storm Limit the broadcast traffic on the port When the broadcast traffic exceeds the customer defined value the system drops the broadcast packets to reduce the broadcast ratio to a reasonable value This efficiently controls the broadcast storm and ensures the network services To enable the function select the Enable Broadcast Control check box Four options are available 5 10 20 or 100 from the Ratio drop down list 100 means broadcast storm is not controlled This feature is disabled by default e MAC Aging Time Four options are available 1 sec 18 sec 75 sec and 300 sec default 3 9 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration e VLAN Type Two options are available 802 1Q based VLAN default and Port based VLAN e IGMP Snooping A multicast control mechanism running on Layer 2 switch It is used for multicast group management and control Based on source address learning the switch learns the MAC address When the layer 2 switch receives multicast packets and cannot judge whether they are multicast or not the switch processes them as broadcast Thus the multicast takes no effect However when IGMP Snooping runs multicast packet is not broadcast on Layer 2 By default this feature is disabled e Rate Limit Options Two options are available Enabled and Disabled default If you enable rate limit you can select the Ingress Egress or both option from the Contr
4. Smart Ethernet Switch Chapter 3 Configuration Av Caution VLAN 1 is the default VLAN which includes all the ports and cannot be deleted 2 Port based VLAN You can create port based VLAN as needed First you need to set the VLAN type to port based VLAN in Figure 3 8 Then choose Advanced Advanced Settings and select the VLAN tab to enter the corresponding dialog box see Figure 3 15 ahs Advanced Settings General WLAN Priority Mapping Priority Weight Advanced Port Settings WYLAN Group Delete VAND 1 R 3345 Ok Cancel Figure 3 15 Port based VLAN configuration 3 17 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration By default VLAN 1 includes all the ports You can only create a VLAN that includes port 1 and port 5 Click lt New gt and you may begin your creation If you need to remove or add some ports in the VLAN click lt Edit gt You can click lt Delete gt to delete a VLAN but when there is only one VLAN left the last VLAN becomes the default VLAN and you cannot delete it Av Caution Changing the VLAN type may cause clearing all the VLAN settings before Port 1 Uplink and port 5 EXP can be added to multiple VLANs While other ports can only be added to a VLAN 3 5 Changing Password Choose Advance Change Password to enter the Change Password dialog box as shown in the following figure To change the password type in the old password a new password
5. complementary description User Manual Aolynk 1505L Smart Ethernet Switch Table of Contents Table of Contents Chapter 1 Product Overview cccccccssssssseeeeeeeeeesesseeeeeeeeeeeenees 1 1 ils AO CALANC O isee n E E T A E T tea 1 1 12 COWIE S atc Sancaetascetie ath eatetaco tienen die enacastetussteeacaneactete 1 3 Chapter 2 Installations si aici eerie ss 2 1 2 MPP CAUTOINS ereun a aaa aa leas 2 1 2 2 Hardware Installation cccccccccsssceceeeeeceeseeseeeeesaneeseaees 2 2 23 USB Driver IAStallatl On iat ranee 2 2 Chapter 3 COnfiquratiomscixs ctccdecceieeiccstcccieetelcts at ctehdencsseassenteietecons 3 1 om els aeprrerercrr mr reer cerremrre rrererremerte erent freer rer errr yr nrrr 3 1 3 2 Main Configuration WiINdOW ccccccceeeessseeseeeeeeeeseeeeees 3 2 3 3 QUICK SOMO ra eoe e E E AESA 3 7 3 4 Advanced Settings ccccccccceccessssseeeeeeeeesseeeseeeeeeesseeaasees 3 8 3 5 Changing PASSWONG siccdeeledee raves uicsdenesteiecinolerlasdetetceodee 3 18 OAD OU eects a ead a 3 19 Chapter 4 Appendix Technical Specifications 0000 4 1 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 1 Product Overview Chapter 1 Product Overview Aolynk S1505L Smart Ethernet Switch hereinafter referred to as the S1505L is oriented to small and medium sized enterprise users and SOHO users for IPTV application It provides five autosensing 10 100Base TX Ethernet ports e Uplink port
6. shielded interface cable Wire the interface cable indoors outdoor wiring is not permitted to prevent the signal ports of the device from damage due to over voltage and over current caused by thunder 2 1 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 2 Installation 2 2 Hardware Installation I Connect the cable As shown in Figure 2 1 you can use the console cable to connect a PC to the S1505L This cable takes an RJ 45 connector at one end and a USB connector at the other end Lp Console cable d i SS i Figure 2 1 PC connection 1 Plug the USB connector of the console cable into the USB port of the PC that will be used to configure the S1505L Plug the RJ 45 connector of the console cable into the EXP port of the S1505L w Il Connect the power adapter 1 Attach one end of the power adapter to the power jack of the S1505L and the other end to the external power socket 2 Check the state of the Power LED ON indicates the S1505L is powered normally 2 0 USB Driver Installation After the above connections are completed you must install the USB driver on the PC according to the following procedure 2 2 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 2 Installation 1 After you plug the USB connector the Found New Hardware Wizard dialog box see Figure 2 2 pops up prompting you that a new hardware is found Found Mew Hardware Wizard Welcome to the Found New Hardware
7. F to 104 F Storage 7 3 F temperature 10 C to 70 C 14 F to 158 F Operating humidity RATT noncondensing o i Storage humidity i noncondensing 10 to 90 4 2
8. Wizard This wizard helps you install software for US6 Seral Controller fs If pour hardware came with an installation CD QEA or floppy disk insert it now What do vou want the wizard to do O Install the software automatically Recommended Click Next to continue Figure 2 2 Found New Hardware Wizard dialog box 2 Select the Install from a list or specific location Advanced option in the above dialog box see Figure 2 2 and click lt Next gt to proceed 2 3 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 2 Installation Found Hew Hardware Wizard Please choose your search and installation options gS Search for the best driver in these locations Use the check boses below to limit or expand the default search which includes local paths and removable media The best diver found will be installed Search removable media floppy CO ROM Don t search will choose the driver to install Choose this option to select the device diver from a list Windows does not guarantee that the diver you choose will be the best match for your hardware Figure 2 3 Select the locations for searching the driver 3 Insert the driver CD ROM into the drive of your PC Select the Search removable media floppy CD ROM check box and click lt Next gt 4 Click lt Continue Anyway gt to ignore the Microsoft logo test and start the installation After the installation the Completing th
9. Wz HUAWEI Aolynk 1505L Smart Ethernet Switch User Manual Manual Version T2 UM 20070710 3 05 Huawei Technologies Proprietary Huawei Technologies Co Ltd provides customers with comprehensive technical support and service For any assistance please contact our local office or company headquarters Huawei Technologies Co Ltd Address 310 Liuhe Road Zhijiang Science Park Hangzhou Zhejiang Province P R China Postal Code 310053 Website http www h3c com Email soho h3c com Copyright Huawei Technologies Co Ltd 2006 2007 All rights reserved No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co Ltd Trademarks and Permissions Wiz Huawei and other Huawei trademarks are trademarks of Huawei Technologies Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders Notice The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ensure accuracy of the contents but all statements information and recommendations in this document do not constitute the warranty of any kind express or implied Huawei Technologies Proprietary CE This equipment complies with the following European Directives 89 336 EEC electromagnetic compatibility 73 23 EEC low voltage Huawe
10. and the new password again Then click lt OK gt User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration he Change Password Username Old Password New Password Confirm Password Figure 3 16 Change Password dialog box A Caution The password is from 4 to 12 characters in length case sensitive and cannot be left blank 3 6 About Choose Help About to view the version and copyright information about the S1505L configuration program 3 19 User Manual Chapter 4 Appendix Technical Aolynk 1505L Smart Ethernet Switch Specifications Chapter 4 Appendix Technical Specifications Table 4 1 Technical specifications tem Description Five autosensing 10 100Base TX Ethernet Ports ports RJ 45 connector Compliant with IEEE 802 3 IEEE 802 3u and IEEE 802 3x 10 100 Mbps transmission rate Half duplex full duplex and auto negotiation Auto MDI MDIX Port attributes 10Base T Category 3 4 5 shielded twisted pair STP with the maximum transmission distance of 100 m 328 ft 100Base TX Category 5 STP with the maximum transmission distance of 100 m 828 ft Physical dimensions 34 x 150 x 110 mm 1 3 x 5 9 x 4 3 in H x W x D Weight 300 g 10 6 oz Input voltage 12 VDC 4 1 User Manual Chapter 4 Appendix Technical Aolynk 1505L Smart Ethernet Switch Specifications tem Description Power 45 W consumption Operating temperature 0 C to 40 C 32
11. e Found New Hardware Wizard dialog box see Figure 2 4 pops up 2 4 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 2 Installation Found Mew Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for Click Finish to clase the wizard Cancel Figure 2 4 Complete the installation 5 Click lt Finish gt to complete the installation 2 5 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration Chapter 3 Configuration You can use the configuration program in the CD ROM accompanying the S1505L to configure and manage the S1505L After the hardware connection and USB driver installation you can run the configuration program on the PC and make a connection to the S1505L for further operation 3 1 Login Run the configuration program and the Login dialog box see Figure 3 1 pops up Type in the password admin by default which you can change after logging in in the Password field Click lt OK gt to enter the main configuration window of the S1505L Username Admin Password er Figure 3 1 Login dialog box 3 1 User Manual Aolynk S1505L Smart Ethernet Switch Chapter 3 Configuration Note The default user name Admin is unchangeable but you can change the password after logging into the configuration page Refer to section 3 5 Changing Password for details 3 2 Main Configuration Window 2 Aolynk Smart Etherne
12. ed aMisabica am Pc Auto Wio ll pisabied a Mbisabica Iam EXP Auto x flowest Disabled Disabled fp Ooo Status Connected COM Port com x Aolynk Smart Ethernet Swich Config Program Copyright C 2005 Huawei Technologies Co Ltd All rights reserved Show Conioustion Warning No part of this program may be reproduced or transmitted in any form Save Configuration or by any means without prior written consent of Huawei Technologies Co Ltd Di isconnect Exit Figure 3 3 Main configuration window in connected status I Quick setup section The quick setup section allows you to set the S1505L quickly In this section you can set the speed priority rate limit flow control and VLAN for each port The Port column of this section indicates the relationship between the port names and their sequence numbers To perform the advanced VLAN configuration you must have knowledge about this e Speed Duplex Select the speed for the port from the drop down list Six options are available Auto default 100 Full 100 Half 10 Full 10 Half Disabled When Auto is 3 3 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration selected the switch automatically negotiates an operating speed and duplex mode with the peer port e Priority Four options are available from the drop down list Highest High Low and Lowest You cannot configure the priority for the Uplink port By default the priorities
13. for the VoIP TV PC and EXP ports are arranged in descending order that is from the Highest VoIP to the Lowest EXP e Rate Limit Port based rate limit This feature controls the packet receiving and transmitting rates on the port and is disabled by default To enable the feature choose Advance Advanced Settings to enter the Advanced Settings dialog box and make configurations on the General tab page For details refer to section 3 4 I General settings Once enabled nine options are available in the drop down list 64K 128K 256K 512K 1M 2M 4M 8M and Disabled e Flow Control This feature controls the packets received and sent on each port to prevent packet loss and is commonly used for congestion management There are two available options Enabled and Disabled default e VLAN You can type in the VLAN ID to create a VLAN containing both this port and the Uplink port By default all the ports have the VLAN ID of 1 and belong to the same VLAN and the Uplink port is tagged Il Buttons e lt Connect gt Click this button to make the program automatically search for the communication port that is 3 4 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration connected to the S1505L to make a connection with the S1505L e lt Show Configuration gt Click this button to display the current configuration of the S1505L e lt Save Configuration gt Click this button to save your configuratio
14. ge as shown in Figure 3 10 In this page you can configure the weights of priority queues The S1505L supports four priority queues for each port and performs polling based on the priority weights of the queues The queues can be set to different weights so that different service qualities are provided for different requirements By default the 3 11 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration weights of the four priority queues are in the ratio of 1 2 4 8 The weight of the lowest queue is 1 which cannot be changed and weights of other queues ranges from 1 to 15 he Advanced Settings Priority Lowest Queue weight 1 Priority Low Queue weight 2 Priority High Queue weight 4 Priority Highest Queue weight 8 Figure 3 10 Priority Weight tab page IV Advanced port settings Choose Advanced Advanced Settings and select the Advanced Port Settings tab to enter the Advanced Port Settings tab page as shown in Figure 3 11 In this page you can perform more configurations on the ports of the S1505L e Ingress Filter The S1505L checks the VLAN ID of the packets on the ingress port For instance if you enable the feature by selecting the Ingress Filter check box for port 2 which does not belong to VLAN 100 the switch drops the 3 12 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration packets with VLAN ID of 100 arriving at port 2 By default ingress f
15. gure 3 12 802 1Q based VLAN configuration 3 14 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration Create a VLAN To create a VLAN click lt New gt on the VLAN tab page see Figure 3 12 to enter the VLAN Member Settings dialog box see Figure 3 13 ED FLAN Group KNember Settings Eg WLAN ID Fort Group Mernber Tag Uplink W Tagged VoIP Figure 3 13 Create a VLAN Type in a VLAN ID in the corresponding text box Select any Member check box to add the corresponding port to this VLAN and then select the Tagged or Untagged option from the corresponding drop down list e Edita VLAN User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration To edit an existing VLAN click lt Edit gt on the VLAN tab page see Figure 3 12 to enter the VLAN Member Settings dialog box see Figure 3 14 bad FLAN Group Nember Settings WLAN ID 1 Fort Group Mernber Tag Uplink Tagged VoIP Untagged TV Untagged Untagged Untagged Cancel Figure 3 14 Edit a VLAN In this dialog box you can remove or add members of the VLAN and change the tag attribute of each port but you cannot change the VLAN ID Delete a VLAN To delete a VLAN select the Member box corresponding to the VLAN in the Advanced Settings dialog box see Figure 3 12 click lt Delete gt and confirm Then the VLAN is deleted User Manual Aolynk 1505L
16. i Technologies Proprietary About This Manual Purpose This document is used to guide you through installing configuring maintaining and managing this product Please read it carefully before your operation Intended Audience This document is intended for network administrators who know well of the basic network knowledge and network terms Organization This document is organized as follows This chapter describes the appearance 1 Product Overview and features of the Aolynk S1505L Smart Ethernet Switch This chapter describes the precautions and 2 Installation steps to install the Aolynk S1505L Smart Ethernet Switch This chapter describes the interfaces of the configuration program and how to configure the Aolynk S1505L Smart Ethernet Switch 3 Configuration 4 Appendix This chapter describes the technical Technical specifications of the Aolynk S1505L Smart Specifications Ethernet Switch Conventions The manual uses the following conventions I GUI conventions Button names are inside angle brackets lt gt i For example click lt OK gt Window names menu items data table and field names are inside square brackets For example pop up the New User window J Multi level menus are separated by forward slashes For example File Create Folder ll Symbols Means reader be careful Improper AN operation may cause data loss or damage Caution to equipment Note Means a
17. ilter is enabled e PVID Used to display and configure the PVID of each port By default the PVIDs displayed here are the same as the VLAN IDs on the main configuration window Fort Ingress Filter PID Uplink v VolP TV PC EXP Figure 3 11 Advanced Port Settings tab page V VLAN Choose Advanced Advanced Settings and click VLAN to enter the VLAN tab page as shown in Figure 3 12 The VLAN management involves creating editing and deleting VLAN The management of 802 1Q based VLAN differs from that of port based VLAN Therefore you should select the required VLAN 3 13 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration type on the General tab page before configuring the VLANs By default this type is 802 1Q based VLAN 1 802 1Q based VLAN Section 3 3 Quick Setup describes how to create an 802 1Q based VLAN Type in the VLAN ID in the corresponding VLAN text box of a port on the quick setup section of the main configuration window For instance after you have created VLAN 10 VLAN 20 VLAN 30 and VLAN 40 for the VoIP TV PC EXP ports respectively these VLANs are shown in Figure 3 12 The information on the VLAN tab page represents the configuration you have made on the main configuration window BE Advanced Settings General VLAN Priority Mapping Priority Weight Advanced Port Settings LAN Group New E dit Delete VAND 20 SU 40 5U m Fi
18. n to the S1505L This operation will cause the S1505L to restart Your configuration takes effect only after you save them e lt Disconnect gt Click this button to disconnect the S1505L from the configuration program e lt Exit gt Click this button to exit the configuration program An Caution Every time you run the configuration program the main configuration window shows the factory default settings At this time if you click lt Save Configuration gt the S1505L will be restored to the factory default settings Therefore once you have run the configuration program you are recommended to click lt Show Configuration gt first to get the configurations of the S1505L and then make changes lll Menus e File Open Configuration allows you to open the configuration file that you have saved on the PC Save Configuration allows you to save the configuration on the S1505L to the PC When configuring multiple S1505Ls you 3 5 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration only need to configure one and choose File Save Configuration to save the configuration to a file Then you can just choose File Open Configuration to open the saved configuration file and click lt Save Configuration gt on the main configuration window to configure other S1505Ls Advanced Language Help Open Configuration Ctrlto cave Contiguration Ctrlts Exit Figure 3 4 File menu items e Advanced
19. nual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration 4 Click lt Save Configuration gt to save the configuration to the S1505L The switch automatically restarts and the configuration takes effect Note e VLAN 1 is the default VLAN including all the ports e A VLAN ID ranges from 1 to 4094 e Toset the VLAN type choose Advanced Advanced Settings and enter the General tab page to make a selection from the VLAN Type drop down list The default VLAN type is 802 1Q based e You can set the speed priority rate limit and flow control from the corresponding drop down lists in the quick setup section The S1505L operates normally with the default settings so generally you do not need to change the default ones 3 4 Advanced Settings You can make advanced settings of the S1505L by choosing Advanced Advanced Settings to enter the Advanced Settings page I General settings Choose Advanced Advanced Settings and select the General tab to enter the general tab page as shown in Figure 3 8 3 8 User Manual Aolynk S1505L Smart Ethernet Switch Chapter 3 Configuration he Advanced Settings Broadcast Storm Enable Broadcast Control Ratio MAC Aging Time VLAN Type 1 sec 18 sec 802 10 based WYLAN f 75 sec f 300 sec IGMP Snooping Disabled Rate Limit Options Soft Reset Fate Limit Di bled ssa Reset Switch Control T ype Figure 3 8 General tab page e
20. ol Type drop down list e Soft Reset Click lt Reset Switch gt and the S1505L restarts Note that you should save current configuration to the S1505L before clicking this button otherwise the changes you make will not take effect Il VLAN priority mapping Choose Advanced Advanced Seitings and select the VLAN Priority Mapping tab to enter the VLAN Priority Mapping tab page as shown in Figure 3 9 In this page you can map the priorities of VLAN tag to corresponding priority queues The S1505L supports four priority queues for each port that is highest high low and lowest queues It places an Ethernet frame into a corresponding output queue based on the priority of the VLAN tag in the frame The frames in the queue with higher priority will be sent in 3 10 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration precedence By default the mapping is as follows 0 and 1 are mapped to the lowest queue 2 and 3 to low 4 and 5 to high 6 and 7 to highest he Advanced Settings WLAN Priority O to Lowest 0 amp WLAN Priority 7 to Lowest 0 amp VLAN Friority 2 bo Loy sd VLAN Priority 3 to Low WLAN Priority 4 to High LAN Priority 5 to High VLAN Priority 6 to Highest o VLAN Priority 7 to Highest amp Figure 3 9 VLAN Priority Mapping tab page Ill Priority weight Choose Advanced Advanced Settings and select the Priority Weight tab to enter the Priority Weight tab pa
21. t Switch Config Program 1505L 7 Oy gt ile g up to Yow Smart Ethernet Switch PNN alte T ji Port Speed Duplex Priority Rate Limit Flow Control File Advanced Language Help Uplink REM risnest isavied Disabled z VolP m Wiii Wosa Alioa TV Auto z High zf Disabled z Disabled z pc to tow Mose Aliisa i EXP Auto Lowest M Disabled i Status Disconnected COM Port COM1 Aolynk Smart Ethernet Swich Config Program Connect Copyright C 2005 Huawei Technologies Co Ltd All rights reserved Warning No part of this program may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co Ltd Figure 3 2 Main configuration window in disconnected status After you log into the S1505L configuration page click lt Connect gt and the program automatically searches for the COM port that is connected to the S1505L to make a connection with the S1505L Once the connection is set up the Status field displays Connected 3 2 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 3 Configuration on the page and the exact port is displayed in the COM Port field see Figure 3 3 UI Aolynk Smart Ethernet Switch Config Program File Advanced Language Help ep S1505L 7 Na Smart Ethernet Switch P E Z Port Speed Duplex Priority Rate Limit Flow Control Uplink R frishest Disabled Disables gt VoIP Auto lihis ll isabi
22. t most Port Broadcast storm control Flow control compliant with 802 3x MAC media Address learning with default address aging access control time of 300 seconds address table Maximum MAC address entries 2 K Management via configuration program 802 1p priority queue Four priority queues per port Rate limit on each port QoS quality of service 1 3 User Manual Aolynk 1505L Smart Ethernet Switch Chapter 2 Installation Chapter 2 Installation 2 1 Precautions Before cleaning the S1505L pull out its power adapter Do not clean the S1505L with wet cloth or liquid Do not place the S1505L near water or in a damp area And prevent water or moisture from entering the S1505L chassis Keep the working environment of the S1505L clean for dusty environment may cause electrostatic adsorption which may not only shorten the life of the device but also incur communication failures The S1505L use air cooling approach for they just generate a small amount of heat Reserve more than 10 cm 4 in of clearance around the S1505L for heat dissipation Make sure that the supply voltage is consistent with that labeled on the S1505L It is strongly recommended that you use the power adapter accompanying the S1505L for the power supply Keep the S1505L far away from powerful radio transmitters radars and high frequency devices working in high current Take electromagnetic shielding measures if necessary For example you can adopt
Download Pdf Manuals