1.  rear of the unit  see Figure 2      cc0019       Figure 2  Outside cover screw locations  rackmount version     Outside Cover Removal Procedures    1  Turn off power to the AIT Library and then unplug it from the AC  power source     2  Remove the appropriate screws that secure the outside cover to the unit     3  Slide the outside cover toward the rear of the unit until it clears the lip  behind the front panel     4  Lift the outside cover up and away from the unit     5  Save the hardware for re use     4 Compaq StorageWorks SSL2000 Series Library Drive Upgrade Reference Guide    Removing the Brace Plate and Upper   Drive Mounting Plate  The brace plate and upper drive mounting plate must be removed to gain  access to the drive area  To remove both plates     1  Remove the outside cover     2  Remove the four screws that secure the brace plate to the chassis  0  Figure 3         Figure 3  Brace plate removal    Adding a Second Drive 5    3  Remove the screws that secure the upper drive mounting plate to the  chassis  see Figure 4      4  Lift out the upper drive mounting plate        Figure 4  Upper drive mounting plate removal    6 Compaq StorageWorks SSL2000 Series Library Drive Upgrade Reference Guide    Installing Alignment Pins    Four alignment pins need be installed into the new drive prior to installation   Each alignment pin consists of a plastic spacer  top hat  and a screw       Figure 5     To install the alignment pins     1  Place a plastic spacer onto each 
2. Compaq StorageWorks    SSL2000 Series Librarv  Drive Upgrade    Reference Guide    First Edition  April 2000   Part Number 187194 001  Compaq Computer Corporation    Notice       2000 Compaq Computer Corporation   Compaq  the Compaq logo  and StorageWorks Registered in U  S  Patent and Trademark Office     All other product names mentioned herein may be trademarks or registered trademarks of their  respective companies     Compaq shall not be liable for technical or editorial errors or omissions contained herein  The  information in this document is subject to change without notice     The information in this publication is subject to change without notice and is provided    AS IS     WITHOUT WARRANTY OF ANY KIND  THE ENTIRE RISK ARISING OUT OF THE USE OF  THIS INFORMATION REMAINS WITH RECIPIENT  IN NO EVENT SHALL COMPAQ BE  LIABLE FOR ANY DIRECT  CONSEQUENTIAL  INCIDENTAL  SPECIAL  PUNITIVE OR  OTHER DAMAGES WHATSOEVER  INCLUDING WITHOUT LIMITATION  DAMAGES FOR  LOSS OF BUSINESS PROFITS  BUSINESS INTERRUPTION OR LOSS OF BUSINESS  INFORMATION   EVEN IF COMPAQ HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH  DAMAGES  THE FOREGOING SHALL APPLY REGARDLESS OF THE NEGLIGENCE OR  OTHER FAULT OF EITHER PARTY AND REGARDLESS OF WHETHER SUCH LIABILITY  SOUNDS IN CONTRACT  NEGLIGENCE  TORT  OR ANY OTHER THEORY OF LEGAL  LIABILITY  AND NOTWITHSTANDING ANY FAILURE OF ESSENTIAL PURPOSE OF ANY  LIMITED REMEDY     The limited warranties for Compaq products are exclusively set forth in the docume
3. an access the Compaq website at  http   www compaq com     Compag Authorized Reseller  For the name of your nearest Compaq authorized reseller   m In the United States  call 1 800 345 1518   m In Canada  call 1 800 263 5868     m Elsewhere  see the Compaq website for locations and telephone  numbers     Adding a Second Drive    Introduction    This guide explains how to add a second tape drive to the Compaq  Storage Works SSL2000 Series Librarv  AIT Librarv         IMPORTANT  All screws that do not use lock washers  captive washers  or lock nuts  must have Loctite 222 applied when parts are reassembled in the field  If you ignore this  step  you might cause premature failure of the mechanism        This chapter includes procedures for     m Removing the outside cover   E Removing the brace plate and upper drive mounting plate  m Installing alignment pins  a    Installing the new drive    2 Compaq StorageWorks SSL2000 Series Library Drive Upgrade Reference Guide    Removing the Outside Cover    This section describes how to remove the outside cover from both the tabletop  and rackmount versions of the Compaq StorageWorks SSL2000 Series  Library     Outside Cover Screw Locations    The outside cover for the tabletop version is held in place by four screws at the  sides of the unit  see Figure 1            Figure 1  Outside cover screw locations  tabletop version     Adding a Second Drive 3    The outside cover for the rackmount version is held in place bv two screws at  the top
4. e leveling jacks     m The stabilizing feet are attached to the cabinet if it is a single cabinet  installation     The cabinets are coupled together in multiple cabinet installations     Only one component is extended at a time  A cabinet may become  unstable if more than one component is extended for any reason        Getting Help    If you have a problem and have exhausted the information in this guide  you  can get further information and other help in the following locations     Compaq Technical Support    In North America  call the Compaq Technical Phone Support Center at  1 800 OK COMPAQ  This service is available 24 hours a day  7 days a week   For continuous quality improvement  calls may be recorded or monitored     Outside North America  call the nearest Compaq Technical Support Phone  Center  Telephone numbers for world wide Technical Support Centers are  listed on the Compaq website  Access the Compaq website at  http   www compaq com     Be sure to have the following information available before vou call Compaq   Technical support registration number  if applicable    Product serial number   Product model name and number   Applicable error messages   Add on boards or hardware    Third partv hardware or software    Operating svstem tvpe and revision level    viii Compaq StorageWorks SSL2000 Series Library Drive Upgrade Reference Guide    Compaq Website    The Compaq website has information on this product as well as the latest  drivers and Flash ROM images  You c
5. electrical shock hazards   do not open this enclosure           AG    Any RJ 45 receptacle marked with these symbols indicates a Network  Interface Connection    WARNING  To reduce the risk of electrical shock  fire  or damage to  the equipment  do not plug telephone or telecommunications  connectors into this receptacle           AA    Any surface or area of the equipment marked with these symbols  indicates the presence of a hot surface or hot component  If this  surface is contacted  the potential for injury exists    WARNING  To reduce the risk of injury from a hot component  allow  the surface to cool before touching           A    Power Supplies or Systems marked with these symbols  indicate the equipment is supplied by multiple sources of    ames om    T       WARNING  To reduce the risk of injurv from electrical shock   remove all power cords to completelv disconnect power from  the svstem           AA    Any product or assembly marked with these symbols indicates that  the component exceeds the recommended weight for one individual  to handle safely     WARNING  To reduce the risk of personal injury or damage to the  equipment  observe local occupational health and safety  requirements and guidelines for manual material handling        About This Guide vii    Cabinet Stabilitv       A WARNING  To reduce the risk of personal injury or damage to the equipment   be sure that   m The leveling jacks are extended to the floor   m  The full weight of the cabinet rests on th
6. nnzznenznznna 5  Figure 5  Alignment pin installation            sse nnnnnenennnnnnnnnnnnnn nem nanna 6  Figure 6  Installing the new drive    eennnnnenenennnnnnnnn nases nesa nn n tna 7    Figure 7  Connecting the new drive    nenenennzenznnnennnznnnnnnnnnnn anna nn 8    About This Guide    This guide is designed to be used as step bv step instructions for installing a  second drive into a Compaq StorageWorks SSL2000 Series Library     Symbols in Text    These symbols may be found in the text of this guide  They have the following  meanings        WARNING  Text set off in this manner indicates that failure to follow directions  L     in the warning could result in bodily harm or loss of life           7 CAUTION  Text set off in this manner indicates that failure to follow directions  could result in damage to equipment or loss of information           IMPORTANT  Text set off in this manner presents clarifying information or specific  instructions        NOTE  Text set off in this manner presents commentary  sidelights  or interesting points  of information     vi Compaq StorageWorks SSL2000 Series Library Drive Upgrade Reference Guide    Symbols on Equipment    These icons may be located on equipment in areas where hazardous conditions    may exist        AAS    Any surface or area of the equipment marked with these symbols  indicates the presence of electrical shock hazards  Enclosed area  contains no operator serviceable parts    WARNING  To reduce the risk of injury from 
7. ntation  accompanying such products  Nothing herein should be construed as constituting a further or additional  warranty     Printed in the U S A     Compaq StorageWorks SSL2000 Series Library Drive Upgrade Reference Guide  First Edition  April 2000   Part Number 187194 001    Contents    About This Guide  Symbolsin Textron wad o a Ta v  Symbols on  Equipment  sern E E S A AE A OEE RS vi  Cabinet Stability esr n Ai A beds la ez ed kee p b i R ANENE vii  Getting Help ss issib i iba a fta das sw f da tt a a ati vii  Compaq Technical Support    nnnenennnnnnennn nanna nesa nanna vii  Compa    Website ca een ete a p b ta i pest plot Si Bed pub shee Save 2 vili  Compaq Authorized Reseller  misiismo eiai ners EA viii  Adding a Second Drive  Introductio Maei e a r ee Ae ea a 1  Removing the Outside Covet    enee E E EASO RRR 2  Outside Cover Screw Locations sinsicniiiisiecnni iain inina 2  Outside Cover Removal Procedures    nee nenenennnnnn en nenn sea 3  Removing the Brace Plate and Upper Drive Mounting Plate        mm 4  Installing Alignment Pins        nn E nenn nases ann nanna stenna 6  Installing the New Drive i isco  idea ee pig ssa bba za dos aa Best iU 7  List of Figures  Figure 1  Outside cover screw locations  tabletop Version     seen 2  Figure 2  Outside cover screw locations  rackmount Version     ss sseeeseensenezza 9  Figure 3  Brace plate removal     isse zin ji iesiiu And si see e sabe ssp eb et 4  Figure 4  Upper drive mounting plate removal    eee eennnnennznnnzz
8. of the four screws     2  Install the alignment pins at the locations shown     Figure 5                              cc0022       Figure 5  Alignment pin installation    Adding a Second Drive 7    Installing the New Drive    To install the new drive   1  Align the new drive with the holes at the bottom of  the chassis     2  Lower the new drive into the chassis  see Figure 6      cc0023       Figure 6  Installing the new drive    8 Compaq StorageWorks SSL2000 Series Library Drive Upgrade Reference Guide    3        Connect the power cable 0  serial cable    and SCSI cable    to the  new drive  see Figure 7      cc0024    Figure 7  Connecting the new drive    4     Secure the upper drive mounting plate to the new drive and chassis  using the previously removed retaining screws       Secure the brace place to the chassis using the previously removed    retaining screws       Place the outside cover onto the chassis and then slide it forward until it    is flush with the front panel       Secure the outside cover to the chassis using the previously removed    SCrews       Connect the AIT Library to an AC power source       Turn the AIT Library on and test the operation of the new drive     
    