Home

HP FCA2404 User's Manual

image

Contents

1. 60 IP o nr Rear 61 Figures t AB232A ABA paiono ii a ee pe er er 15 2 Add Binding window cada ee en nee 43 3 Lunmap WindoW 2 see Oe ne 45 Tables 1 Document Conventions 0 0 cc eee eet ence ene nes 9 2 AB232A HBA Diagram Description 15 3 Normal POST LED Indicators 22 4 Normal POST LED Indicators 28 5 SCSI Port Error Log Codes 30 6 Cmdstat Vall s is eee da a eae Ea Rene ra 32 7 Parameter Error Values Valid only when CmdStat 0x3 33 8 Drive Parameters s 444 aie hha wana deat sn se ee I nta 39 9 AL PA Values nena er a an Den 42 AB232A PCI X Host Bus Adapter Installation Guide 5 Contents 6 AB232A PCI X Host Bus Adapter Installation Guide about this guide This installation guide provides information to help you m Install configure and use the diagnostic utilities for the AB232A PCI X host bus adapter for 64 bit Windows systems m Contact technical support for additional assistance About this Guide topics include m Overview page 8 m Conventions page 9 Getting Help page 11 AB232A PCI X Host Bus Adapter Installation Guide 7 About this Guide Overview This section covers the following topics m Intended Audience m Related Documentation Intended Audience
2. 25 Device Driver Installation 26 System Requirements syed eae Ga tae a a 26 Installing or Upgrading a New Driver 26 Installing the LightPulse Utility 27 AB232A PCI X Host Bus Adapter Installation Guide 3 Contents 4 Troubleshooting uem ee ia a 29 POST Conditions and Results 30 Using The Event Viewer cia a pU RL RATS Rs t eee 31 Windows Miniport Event Log Codes 32 5 Diagnostic and Configuration Utilities 37 Using LightPulse Utility cosa ek de i e a 38 View HBA P r meters iaia iaia a a eed ee 38 Modify Diagnostic Driver Parameters in the Windows Registry 40 Modify the Driver Parameters 40 Set Up Persistent Binding 44 Prerequisites ipso acea ec aaa rn aiar 45 Setting Up Persistent Binding 45 Global Automap and Unmasking Overview 46 Prerequisites ccs 2 4 24 veu pen Heer ee a ERO eer 46 Mapping and Masking LUNS 47 Test Host Bus Adapters 47 Modify Test Options viii c
3. n Values are milliseconds from 500 to 10000 Default 1000 Represents FC_AL arbitration time out prior to LIP Class n Values from 0 to 2 Default 2 Controls which Fibre Channel Class will be used O Class 1 1 Class 2 2 Class 3 EDTOV n Values are in milliseconds from 500 to 10000 Default 1000 Represents error detect time out value prior to LIP EnableDPC n Values 0 or 1 Default 0 0 process I O completion at interrupt level 1 process at DPC level FrameSizeMSB n Values from 1 8 Default 8 Controls the upper byte of the receive FrameSize if issued in PLOGI This allows the FrameSize be constrained on 256 byte increments from 256 1 2048 8 HardALPA Oxn Values from 0x01 OxEF Default 0x01 allows the HBA use a hard assigned loop address NOTE Only valid ALPAs can be used see Table 9 on page 44 LinkTimeOut n Values are in seconds from 1 500 Default 60 Controls the time out at which link no longer busy with requests but issues SELECTION_TIMEOUT error status LogErrors n Values 0 or 1 Default 0 0 don t log general HBA drive errors 1 use Event Log to log general errors NodeTimeOut n Values are in seconds from 1 255 Default 10 Controls the time out at which a formerly logged in node will issue SELECTION_TIMEOUT error status to an I O request AB232A PCI X Host Bus Adapter Installation Guide 41 Diagnostic and Configuration Utilities Table 8 Drive
4. 0 amp amp pendingsrb NULL OxF8 Invalid FCP_RSP 0x11 pcpentrl 12 scsisat 13 len OxF9 Two consec time outs issue LIP OxFA START_IO error 0x11 errtype 12 srbstat 13 linkup OxFB ELS REQ CR IOCB rsp err 0x11 cmdstat 12 parm err 13 ALPA OxFC ELS REQ CR IOCB rsp err 0x11 cmdstat 12 parm err 13 ALPA FLOGI failed 0x11 cmdstat 12 parm err OxFF SNS PLOGI failed 0x11 cmdstat 12 parm err Table 6 CmdStat Values Ox11 Offset Explanation Further Information IOSTAT_REMOTE_STOP Remote sent an ABTS Parameter field contains additional information IOSTAT_FBRIC_BSY AB232A PCI X Host Bus Adapter Installation Guide Troubleshooting Table 6 CmdStat Values Continued o8 IOSTAT_INTERMED_RSP IOSTAT_LS RJT Remote sent LS_RJT IOSTAT_BA_RJT Remote sent BA_RJT Table 7 Parameter Error Values Valid only when CmdStat 0x3 0x12 Offset Explanation Further Information CO IGES C 6 03 TOERRLINTERNALERROR 7 p fomno wos froenn ILEGAL I wor foen xene Rorre TEGAL A E ODA IOERR TOC MANY SUFFERS 5 08 OERRROVBUFFERWATING voc IERR NO CONNECTON eo fomno 070 OBRA TRA DA O wr OBRA NO RESOURCES wma OBRA RESERVED ws foen meon ene OOo 0x14 IOERR_UNSUPPORTED_ FEATURE OERR ABORT N PROGRESS AB232A PCI X Host Bus Adapter Installation Guide 35 Troublesh
5. 12 technical support 11 61 Index installation overview 17 procedure 20 requirements 18 verifying 22 Windows drivers 26 L laser devices 58 LightPulse Utility input and output files 48 loading on Windows 2003 Server 27 modifying driver parameters 40 45 modifying test options 48 overview 38 restarting HBAs 48 showing HBA information 48 updating flash ROM parameters 48 viewing HBA parameters 38 LpUtilNt see LightPulse Utility 38 P parameter error values 35 POST LED indicators verifying HBA installation 22 30 R reference numbers 19 Regulatory Compliance notices 53 related documentation 8 S SCSI Miniport drivers event log codes 32 62 overview 25 Windows requirements 26 showing HBA information 48 specifictions performance 16 symbols in text 9 on equipment 10 system requirements HBA installation 18 T technical support HP 11 test options modifying 48 text symbols 9 troubleshooting CmdStat values 34 parameter error values 35 SCSI Miniport driver event logs 32 using POST LED results 30 Windows Event Viewer 31 U udating drivers 26 utilities LightPulse 27 38 V viewing HBA parameters 38 W websites HP storage 12 Windows Event log 31 Event Viewer 31 installing or updating drivers 26 loading LightPulse utility 27 SCSI Miniport drivers 25 system requirements 26 AB232A PCI X Host Bus Adapter Installation Guide
6. 4 4 IEC61000 4 5 IEC61000 4 6 IEC61000 4 8 IEC61000 4 11 Electromagnetic Immunity EN60950 IEC60950 Product Safety Power Quality IEC610000 3 2 Harmonics and IEC61000 3 3 Voltage Fluctuations and Flicker m Also approved under UL 1950 3rd Edition CSA C22 2 No 950 95 Safety of Information Technology Equipment AB232A PCI X Host Bus Adapter Installation Guide 55 Regulatory Compliance Notices Japanese Notice CEZAR o CVA EIBIZVCCIV 7 BITTE LES ROME BRA FAV ORE ARLES BREA ER BRA VCC ORE CESS 7 2 ABf RRR CT OUI ZERA CHATS ZAWELCTWETA COED IVARCTVEV a VRE LT WASHAL SARs ITI LDN ES DARE R gt TIE LW RY MWe UTA VCCEIv Y AUTANT ROALIER FEV CORK RR ES RIS AER i VCCD Ole HI lt K73F ZAIRE CT OES AER CHATS BR WES SEITE ADD ES ZONEN EIET aR ET HLIBRANAZLERHVET HT 56 AB232A PCI X Host Bus Adapter Installation Guide Harmonics Conformance Japan RARI FT DS German Noise Declaration Schalldruckpegel Lp 70 3 dB A Am Arbeitsplatz operator position Normaler Betrieb normal operation Nach ISO 7779 1988 EN 27779 1991 Typpriifung AB232A PCI X Host Bus Adapter Installation Guide Regulatory Compliance Notices 57 Regulatory Compliance Notices Laser Safety A WARNING To reduce the risk of exposure to hazardous radiation e Do not try to open the laser device enclosure There are no user serv
7. PCI X Host Bus Adapter Installation Guide Installation This chapter provides step by step instructions for installing the AB232A HBA including Hardware Requirements Recording Reference Numbers Installing the HBA into a Computer Verifying the Installation Configuration Guidelines This chapter also provides information on installation guidelines and supported configurations for the operating systems Caution The HBAs contain static sensitive components Make sure you EN comply with Electrostatic Discharge ESD procedures described on page 59 AB232A PCI X Host Bus Adapter Installation Guide 17 Installation Hardware Requirements The system hardware requirements for installing the HBAs include m AB232A HBA requires one open 64 bit 133 MHz PCI X universal slot m Multimode fiber optic cable with LC connector used with shortwave lasers 18 AB232A PCI X Host Bus Adapter Installation Guide Installation Recording Reference Numbers Each HBA ships with a unique address identifier that is stored in flash memory Fibre Channel industry standards issue two unique identifiers WorldWide Port Name WWPN and Node Name NN each of which is derived from the HBA s IEEE address Combined the WWPN and NN create the WorldWide Name WWN which is an 8 byte field that uniquely identifies an HBA on a FC circuit The WWN address and serial number are clearly marked on the HBA Record the addresses on the lines below for
8. other static sensitive devices This type of damage can reduce the life expectancy of the device To prevent electrostatic damage observe the following precautions m Avoid hand contact by transporting and storing products in static safe containers m Keep electrostatic sensitive parts in their containers until they arrive at static free workstations m Place parts on a grounded surface before removing them from their containers Avoid touching pins leads or circuitry Always make sure you are properly grounded when touching a static sensitive component or assembly AB232A PCI X Host Bus Adapter Installation Guide 59 Electrostatic Discharge Grounding Methods There are several methods for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts m Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper grounding wear the strap snug against the skin m Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats m Use conductive field service tools m Use a portable field service kit with a folding static dissipating work mat If you do not have any of the suggested equipment for proper grounding have an HP auth
9. radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense Declaration of Conformity for Products Marked with FCC Logo United States Only 52 This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications AB232A PCI X Host Bus Adapter Installation Guide Regulatory Compliance Notices Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense The end user of this product should be aware that any changes or modifications made to this equipment without the approval of Hewlett Packard could result in the product not meeting the Class A limits in which case the FCC could void the user s authority to operate the equipment Network and Serial Cables Connections to this device must be made with shielded cables with metallic RFI EMI connector hoods in order to maintain compli
10. time out between phases of Off line to On line protocol ScanDown n Values 0 or 1 Default 0 0 Lowest AL_PA Lowest physical disk ascending AL_PA order 1 Highest AL_PA Lowest Physical Disk ascending SEL_ID order 42 AB232A PCI X Host Bus Adapter Installation Guide Diagnostic and Configuration Utilities Table 8 Drive Parameters Continued Parameter Description SilFlags n Values from 0 2 Default 0 Controls which driver interface to use 0 automode attempt SLI 2 first If that fails uses SLI 1 1 always use SLI 1 2 always use SLI 2 SimulateDevice n Values 0 or 1 Default 0 O do not create a dummy disk device 1 create a dummy disk to force the driver to load even if no disk devices are present at boot time SnsALL n Values 0 or 1 Default 1 Controls which N_Ports are queried from the NameServer 0 SCSI FCP only 1 All N_Ports Topology n Value 0 through 3 Default 2 0 FC_AL loop 1 PT PT Fabric 2 FC AL first then attempt PT PT 3 PT PT first then attempt FC AL When set to 1 FLOGI SCR RSCN and NameServer queries are employed TrafficCop n Values 0 or 1 Default 0 1 enable FC AL loop master to run unfair and break potential arbitration problems by sending frames to itself 0 run fair all the time AB232A PCI X Host Bus Adapter Installation Guide 43 Diagnostic and Configuration Utilities Table 9 lists the Arbitrated Loop Physical Addres
11. Click on a target and click Add The Add Binding window displays as shown in Figure 2 Bind ire fwwrn SCS But fi T SCSI ld p GR Cancel Figure 2 Add Binding window Click the target to be bound from the Unbound Targets list If required change the Bind Type for the target If required change the SCSI Bus and SCSI ID values Click OK The letters PB display next to the target row JAR RB AB232A PCI X Host Bus Adapter Installation Guide 45 Diagnostic and Configuration Utilities Global Automap and Unmasking Overview Prerequisites 46 Global Automap All Targets defaults to enabled to allow the driver to detect all Fibre Channel devices attached to the HBAs If Global Automap All Targets is disabled the driver detects Fibre Channel devices attached to the HBA and does not pass them to the operating system unless they are already persistently bound Global Automap All LUNs defaults to enabled and assigns an operating system LUN ID to a Fibre Channel LUN ID for all LUNs behind the targets in your SAN LUN mapping can also be enabled and disabled at the target level Global automapping of LUNs is different from persistent binding Global LUN automapping does not concern itself with the SCSI ID or SCSI Bus This is because the global LUN mapping stays the same for the target when the system is rebooted Globally Unmask All LUNs defaults to enabled to allow the operating system to see all LUNS behind targets
12. HBA for repair Mailbox cmd time out 0x11 command 32 AB232A PCI X Host Bus Adapter Installation Guide Troubleshooting Table 5 SCSI Port Error Log Codes Continued 0x10 Offset Explanation 0x11 to 0x13 Further Information OxE3 Mailbox rsp err 0x11 command 12 13 mbxstatus OxE4 HBA not ready after init Status register bytes 1 3 in event 11 13 OxE5 Requested loop but link PT PT OxE6 Mailbox int but cmd not 0x11 MB cmd 12 13 mbxstatus complete OxE7 SRB already queued to ring OxE8 RESTART failed OxE9 PORT BYPASS LPB received OxEB Unknown IOCB cmd rsp 0x11 15 8 cmd field OxEC Uncached extension alloc error OxED Link down boot time 30 sec OxEF Too many interrupts at initial boot OxF1 LinkUp error LP8 down 0x11 parameter field 12 IOCB driver up cmd OxF2 LinkUp w illegal or corrupt 0x11 parameter field 12 IOCB RPI cmd OxF3 DeQueue 0x11 caller ID ring gt iotemd head OxF4 HBA reset 0x11 coded reason for reset Bit 0 IOCB requeue bit 1 readla retry Bit 2 initlink retry bit 3 rstbus retry Bit 4 mailbox time out OxF5 PCP_IXXX_CR IOCB rsp 0x11 cmdstat 12 parm err 13 err ALPA AB232A PCI X Host Bus Adapter Installation Guide 33 Troubleshooting 34 Table 5 SCSI Port Error Log Codes Continued 0x10 Offset Explanation 0x11 to 0x13 Further Information OxF6 PCP_IXXX_CR IOCB rsp 0x11 cmdstat 12 parm err 13 err ALPA OxF7 Ring hd
13. Host Bus Adapter Installation Guide 25 Installing the SCSI Miniport Driver Device Driver Installation This section describes the instructions for installing the Windows SCSI Miniport driver System Requirements Ensure that your system meets these minimum requirements m Installed HBA m StorageWorks Fibre Channel Storage subsystem interconnect device and storage device Installing or Upgrading a New Driver The AB232A HBA is a plug and play device that is detected by Windows operating systems Perform the following steps to add or update the Windows driver to a previously installed Windows system 1 Install the HBA as described in Chapter 2 on page 17 2 Restart or turn on the computer 3 Browse to the the driver kit on the Smart Setup CD ROM or one you downloaded from the website if it is more recent 4 Double click cp00xxxx exe Note Refer to the following website for the information about this Smart Component s final version number htto h1 8000 www1 hp com storage saninfrastructure html Follow the installation wizard instructions When the installation completes you must reboot Repeat step 1 through step 6 for any additional HBAs Make sure to reboot after installing the driver for the last HBA 26 AB232A PCI X Host Bus Adapter Installation Guide Installing the SCSI Miniport Driver Installing the LightPulse Utility The LightPulse Utility LpUtilNt described in Diagnostic and Configuratio
14. If Globally Unmask All LUNS is set to disabled and you want the operating system to see all LUNS behind a specific target you must set unmasking at the target level Installed SCSI Miniport driver Installed LightPulse Utility A target device with LUNs that have been properly configured LUN Automap enabled and LUN Unmasking disabled on the LUN Mapping window If LUN Automap is enabled for the target you can map each LUN individually Unless LUNs were previously mapped if LUN Automap is disabled for the target no LUNs will be mapped when you reboot the system IfLUN Unmasking is disabled for the target the HBA can see all LUNS behind a specific target AB232A PCI X Host Bus Adapter Installation Guide Diagnostic and Configuration Utilities Mapping and Masking LUNs From the LightPulse Utility Main menu screen 1 Choose the desired HBA 2 Expand the category list and choose Persistent Binding 3 Click on a target The Lunmap button becomes active 4 Click Lunmap The Lunmap window displays as shown in Figure 3 jun Mapping SS Target W WPN5005075207451c20 Lun Automap Enabled Lun Unmasking Disabled Lun Mapping FC Lu Number 0000000000000000 0000000000000000 k Edit 0000000000000000 0000000000000000 Edt Map Enty fO 0000000000000000 Mek Figure 3 Lunmap window Test Host Bus Adapters Choose this option to run host based internal and external loopback tests on the HBAs From t
15. Installation Guide hp Storage Works AB232A PCI X Host Bus Adapter Third Edition June 2004 Part Number AA RUTZC TE This guide describes how to install configure and use the diagnostic utilities for the AB232A PCI X host bus adapter for 64 bit Windows operating systems Ca Copyright 2002 2004 Hewlett Packard Development Company L P Hewlett Packard Company makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material This document contains proprietary information which is protected by copyright No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Hewlett Packard The information contained in this document is subject to change without notice Microsoft Windows and Windows NT are U S registered trademarks of Microsoft Corporation Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein The information is provided as is without warranty of any kind and is subject to change without notice The warranties for Hewlett Packard Company products are set forth in the express limited warranty statements for su
16. Normal 2 Gb link rate Off Blink 1 Hz Normal link down or not yet started 22 AB232A PCI X Host Bus Adapter Installation Guide Installation Configuration Guidelines The software for loading the driver also contains the default registry parameter settings that are loaded as part of the driver installation Consult the following sources for any restriction and for information on supported configurations specific to your operating system and topology m Release Notes m HP Website at htto www hp com country us eng support html AB232A PCI X Host Bus Adapter Installation Guide 23 Installation 24 AB232A PCI X Host Bus Adapter Installation Guide Installing the SCSI Miniport Driver This chapter contains step by step instructions for installing the SCSI Miniport driver System managers must be familiar with the Windows Server 2003 operating system under which the PCI X to Fibre Channel HBA is to operate System managers must also have access to standard system documentation HBA files are updated periodically You can download the latest versions of the HBA driver kits from the HP website at http h18000 www hp com storage saninfrastructure html Note This chapter describes the steps for installing the device driver and for accessing Fibre Channel storage devices For other configuration changes see Modify Diagnostic Driver Parameters in the Windows Registry on page 40 AB232A PCI X
17. Parameters Continued Parameter Description QueueDepth n Values from 1 64 decimal Default 64 Requests per LUN Target see Queue Target parameter QueueTarget n Values 0 or 1 decimal Default 0 0 QueueDepth applies on a per LUN basis 1 QueueDepth applies on a Target basis RATOV n Values are in seconds from 2 to 120 Default 2 This value is the ELS request time out n ReadCheck n Values 0 or 1 Default 1 0 do not enable byte counting for read operations 1 enable byte counting If bytes counted are less than requested transfer count issue underrun ResetFF Values 0 or 1 Default 1 0 ResetBus translates to LIP F7 1 ResetBus translates to LIP FF Used for WolfPack to force reservations to be freed when ResetBus issued Only meaningful for FC_AL topology and Seagate native FC hard drives ResetTPRLO n Values 0 or 1 Default 1 0 ResetBus translates to LIP 1 ResetBus translates to ThirdPartyProcessLogout LIP Used for WolfPack to force reservations to be freed when ResetBus is issued RetryInterval n Values are in seconds from 2 255 Default 45 Used for time out interval if RetryloTimeOut 1 Must be shorter than Class driver TimeOutlnterval RetryloTimeOut n Values 0 or 1 Default 1 1 allows HBA to time out I O prior to port driver s time out that causes a LIP Link Reset RTTOV n Values are in milliseconds from 100 to 511 Default 256 Represents
18. This book is intended for use by system administrators who are experienced with the following m Windows Server 2003 Enterprise Edition 64 bit version m Host bus adapters Related Documentation In addition to this guide refer to the HP StorageWorks AB232A PCI X Host Bus Adapter Release Notes 8 AB232A PCI X Host Bus Adapter Installation Guide About this Guide Conventions Conventions consist of the following m Document Conventions m Text Symbols m Equipment Symbols Document Conventions The document conventions included in Table 1 apply in most cases Table 1 Document Conventions Element Convention Cross reference links Blue text Figure 1 Key and field names menu items Bold buttons and dialog box titles File names application names and text Italics emphasis User input command and directory Monospace font bile and responses output COMMAND NAMES are uppercase ane messages monospace font unless they are case sensitive Variables lt monospace italic font gt Website addresses Blue underlined sans serif font text tip www hp com Text Symbols The following symbols may be found in the text of this guide They have the following meanings WARNING Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death AB232A PCI X Host Bus Adapter Installation Guide 9 About this Guide Cauti
19. Troubleshooting Windows Miniport Event Log Codes The Windows Miniport driver logs events and errors in the Windows Event log Serious errors are always logged Informational events are only logged if the registry parameter LogError 1 is used All Miniport logged events are issued with an Event ID of 11 INTERNAL ADAPTER ERROR but do not necessarily indicate an HBA error occurred Byte offset 0x10 of the event is the driver event code Byte offsets 0x11 to 0x13 contain event specific information Table 5 describes the SCSI port error log codes Table 5 SCSI Port Error Log Codes 0x10 Offset Explanation 0x11 to 0x13 Further Information OxDO SNS REQ XMIT SEQ 0x11 cmdstat 12 parm err failed SNS RSP RCV SEQ 0x11 cmdstat 12 parm err failed RCV ELS REQ failed 0x11 cmdstat 12 parm err XMT ELS REQ failed Ox11 cmdstat 12 parm err Too many targets found 0x11 to 13 D DID that didn t fit 160 SNS request time out 0x11 to 13 no additional information Mailbox interrupt time out 0x11 mailbox word 0 0xD8 TPRLO requested when 0x11 local req state 12 busy discstate 13 mailbox word 0 OxD9 Link down time out 0x11 local req state 12 occurred discstate 13 mailbox word 0 OxDA Hard link down time out 0x11 local req state 12 occurred discstate 13 mailbox word 0 OxE1 Error interrupt occurred Status register bytes 1 3 in event 11 13 E1 error indicates an HBA hardware failure return
20. agram Description Figure Legend 0 Fibre Channel LC connectors e POST LEDs indicators Note See Table 3 on page 22 for detailed descriptions Description AB232A PCI X Host Bus Adapter Installation Guide Adapter Features Performance Specifications The AB232A HBA offers a highly integrated 2 Gbps Fibre Channel HBA for use in Itanium servers based on the latest PCI X expansion bus The features of the AB232A HBA provides the flexibility and broad interoperability needed for complex highly scalable SANs The AB232A HBA also features sophisticated hardware that provides superior performance in SANs and provides best in class server CPU offload This exclusive hardware delivers low latency and high throughput in switched fabric arbitrated loop and clustered environments Support for fiber optic cabling is provided through an embedded small form factor LC optical interface The AB232A HBA is both ANSI Fibre Channel and PCI Local Bus Compliant and supports m Full duplex 2 Gbps Fibre Channel that provides data transfers of up to 400 MBps Full fabric boot support to multiple LUNs FC Tape FC 2 devices Point to point arbitrated loop and switch fabric FC connections Storage protocol Fibre Channel class 2 and 3 Automatic speed negotiation and topology detection End to end parity protection for high data integrity Collectively these characteristics create a high performance Fibre Channel HBA AB232A
21. aintenance Choose this option to update firmware or non volatile parameters in the flash ROM This option also displays program images load list stored in the HBA memory You must reboot the HBA for the new firmware to take effect 48 AB232A PCI X Host Bus Adapter Installation Guide Diagnostic and Configuration Utilities Show Host Bus Adapter Info Choose this option to display HBA data in these areas BIU PCI Configuration Parameters HBA Info and Status Adapter Revisions Display Configuration Data Service Parameters Status Counters Info Link Status Link Attention Quit the LightPulse Utility Choose this option to exit the program A warning message indicates if any errors were encountered during the session AB232A PCI X Host Bus Adapter Installation Guide 49 Diagnostic and Configuration Utilities 50 AB232A PCI X Host Bus Adapter Installation Guide Regulatory Compliance Notices This appendix covers the following topics Federal Communications Commission Notice page 52 Canadian Notice Avis Canadien page 54 European Union Notice page 55 Japanese Notice page 56 Laser Safety page 58 AB232A PCI X Host Bus Adapter Installation Guide 51 Regulatory Compliance Notices Federal Communications Commission Notice Part 15 of the Federal Communications Commission FCC Rules and Regulations has established Radio Frequency RF emission limits to provide an interference free radio frequency spectrum Ma
22. al POST LED Indicators Amber LED L1 Green LED L2 State Off Off Wake up failure dead board On Off POST failure dead board Slow blink 1 Hz Off Wake up failure dead board Fast blink 4 Hz Off Failure in POST dead board Flashing irregular Off POST processing in progress Off On Failure while functioning On On Failure while functioning Slow blink 1 Hz On Normal 1 Gb link rate Fast blink 4 Hz On Normal 2 Gb link rate Off Blink 1 Hz Normal link down or not yet started 30 AB232A PCI X Host Bus Adapter Installation Guide Troubleshooting Using The Event Viewer The Windows SCSI driver verifies the condition of the HBA POST If there is a failure or a suspected failure an error log entry is issued to the Windows Event log Following is the procedure for viewing the event log From the Main menu 1 Double click or choose the Administrative Tools program group 2 Double click or choose the Event Viewer 3 Specify LPXNDS Note You can find the source name in the SCSI device s Disk Manager Double click any event with the source name Change the data view from Bytes default to Words Examine the entry at offset 0x10 if the low byte En match the low byte with the error found in Table 5 on page 32 SCSI Port Error Log Table 6 on page 34 and Table 7 on page 35 list CmdStat values and Parameter error values AB232A PCI X Host Bus Adapter Installation Guide 31
23. ance with FCC Rules and Regulations IEC EMC Statement Worldwide This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Sp cification ATI Classe A France DECLARATION D INSTALLATION ET DE MISE EN EXPLOITATION d un mat riel de traitement de l information ATT class A en fonction des niveaux de perturbations radio lectriques mis d finis dans la norme europ enne EN 55022 concernant la Compatibilit Electromagn tique AB232A PCI X Host Bus Adapter Installation Guide 53 Regulatory Compliance Notices Canadian Notice Avis Canadien Class A Equipment This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada 54 AB232A PCI X Host Bus Adapter Installation Guide Regulatory Compliance Notices European Union Notice Products with the CE Marking comply with both the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community Compliance with these directives implies conformity to the following European Norms the equivalent international standards are in parenthesis m EN55022 1998 CISPR 22 Electromagnetic Interference m EN55024 1998 IEC61000 4 2 IEC61000 4 3 IEC61000
24. ch products Nothing herein should be construed as constituting an additional warranty Printed in the U S A AB232A PCI X Host Bus Adapter Installation Guide Third Edition June 2004 Part Number AA RU1ZC TE contents About this Guide Kesh oon sonne en don aa 7 OVEIVIOW cider ee d eee E aa iA eA eel ae 8 Intended Audience LL 8 Related Documentation e ne E 8 leoni 9 Document Conventions 9 Text Symbols s a alia Ren UAR SN 9 Equipment Symbols mete e wea ee ne 10 Getting Help iubes eee bu eR dhe OR Cem OUR d Ea ee Ke ea ver ACER BA aes 11 HP Technical Support 11 HP Storage Website cec an IE las 12 HP Authorized Reseller 12 1 Adapter Features csi iso a 13 Product Description u A e una 14 Performance Specifications 16 2 CS OO sandra ANN da V RENS SUM 17 Hardware Requirements 18 Recording Reference Numbers 19 Installing the HBA into a Computer 20 Verifying the Installation 22 Configuration Guidelines 23 3 Installing the SCSI Miniport Driver
25. d rt AA a Re A Ra gi A A RRA A 48 Restart Host Bus Adapters 48 Input OULPUb sie dice rear ea ek ede eee dd 48 Maintenance ze ana ia Ei eta Eee ada ae a qe ada 48 Show Host Bus Adapter Info 49 Quit the LightPulse Utility 49 A Regulatory Compliance Notices 51 Federal Communications Commission Notice 52 Class A Equipment sun en e RS a 52 Declaration of Conformity for Products Marked with FCC Logo United States Only 52 Network and Serial Cables 53 IEC EMC Statement Worldwide 53 Sp cification ATI Classe A France 53 Canadian Notice Avis Canadien 54 Class Equipment ici lio a ra 54 European Union Notice isa ma als ad a ea aus 55 Japanese Notice nn en ee A ea tre 56 Harmonics Conformance Japan 57 German Noise Declaration 57 Laser Salety cancer aaa ea si 58 Certification and Classification Information 58 4 AB232A PCI X Host Bus Adapter Installation Guide Contents B Electrostatic Discharge 59 Grounding Methods
26. e following m You must install and connect the SCSI Miniport driver to at least one drive before LightPulse Utilitycan operate properly You can alternately set the registry parameter Simulate Device 1 m LightPulse Utility does not load automatically on Windows Server 2003 systems HP recommends that you install the LightPulse utility after installing the HBA drivers as described in the section Installing the LightPulse Utility on page 27 View HBA Parameters 38 From the LightPulse Utility Main menu screen 1 Choose an HBA 2 Onthe menu bar click on an HBA or pull down the category list 3 Choose an option to view HBA parameters Each of the following options displays a different group of HBA parameters m Adapter Revision Levels View information about the chipset and firmware revision levels of the selected HBA m Firmware Maintenance View detailed information about the firmware in the flash ROM of the selected host adapter Update host adapter firmware and boot code manage existing firmware and enable or disable the BootBIOS bootup message Loop Map View a list of the members of the selected HBA loop map PCI Registers View the values of the PCI configuration registers for the selected HBA AB232A PCI X Host Bus Adapter Installation Guide Diagnostic and Configuration Utilities m Configuration Data View information about the data in each of the configuration regions in the flash ROM of the selected HBA
27. er cover and secure it using the previously removed screws 20 AB232A PCI X Host Bus Adapter Installation Guide Installation 11 Attach media a Connect the fiber optic cable to the LC connector on the HBA b Connect the other end of the cable to the Fibre Channel device Note The HBAs do not allow normal data transmission on an optical link unless the link is connected to a similar or compatible laser product That is both products are multimode to multimode AB232A PCI X Host Bus Adapter Installation Guide 21 Installation Verifying the Installation To verify the HBA is properly installed and is operating 1 Turnon the computer 2 At power up observe the POST LED indicators on the HBA The position of the POST LED indicators is defined in page 15 on page 15 and Table 2 on page 22 of this guide The green LED indicates power functions and the amber LED signifies port activity The amber LED blinks at all times during normal operation Table 3 lists normal LED indications Table 3 Normal POST LED Indicators Amber LED L1 Green LED L2 State Off Off Wake up failure dead board On Off POST failure dead board Slow blink 1 Hz Off Wake up failure dead board Fast blink 4 Hz Off Failure in POST dead board Flashing irregular Off POST processing in progress Off On Failure while functioning On On Failure while functioning Slow blink 1 Hz On Normal 1 Gb link rate Fast blink 4 Hz On
28. future reference Note The WWN is a static identifier that cannot be changed IEEE address Serial number AB232A PCI X Host Bus Adapter Installation Guide 19 Installation Installing the HBA into a Computer Use the following procedure for installing the HBA into a computer Caution Be sure to observe the ESD precautions described on page 59 for N this procedure Make sure the computer is powered off Remove the screws on the computer cover and then remove the cover Wearing a static wrist strap remove the blank panel from an empty 64 bit PCI X bus slot Compare the removed panel to the bracket on the HBA Follow steps 4 7 to change the bracket if the brackets are different sizes Note The HBAs come with a standard PCI bracket installed The low profile mounting bracket is shorter than the standard bracket approximately 7 9 cm 3 11 in compared to 12 06 cm 4 75 in long 4 Remove the mounting bracket screws from the top of the HBA 5 Remove the bracket and store it for future use 6 Align the new mounting bracket tabs with the holes in the HBA Note Be careful not to push the bracket past the transceiver housing s grounding tabs 7 Replace the screws that attach the HBA to the bracket Insert the HBA into the empty PCI X bus slot press firmly until it is seated securely 9 Secure the HBA mounting bracket to the computer panel with the panel screws 10 Replace the comput
29. he LightPulse Utility Main menu screen 1 Choose Test Host Bus Adapters 2 Enable or disable the external loopback tests a Enable the external loopback tests by choosing 1 Y The default is disabled 0 No Internal BIU PCI loopback and other loopback tests are run automatically b Choose 0 No if you do not have an external loopback connector AB232A PCI X Host Bus Adapter Installation Guide 47 Diagnostic and Configuration Utilities Note Testing the HBA while it is connected to an arbitrated loop is not recommended Modify Test Options Use this option to specify the number of passes on one or more of these tests PCI loopback internal loopback external Loopback or all three From the LightPulse Utility Main menu screen 1 Choose Test 2 Choose the following data for the PCI loopback Internal loopback External Loopback tests a The number of passes The default is 0x50 O infinity b Theaction to take upon encountering errors Choose one of the following 0 stop default 1 repeat 2 ignore Restart Host Bus Adapters Choose this option to reset the HBA When a restart HBA occurs the HBA performs POST testing and reloads functional firmware Input Output Choose this option to open or close input and output files The contents of the input file are interpreted and executed by the program The output file contains a log of all messages Note that nesting of input files is not supported M
30. iceable components inside Do not operate controls make adjustments or perform procedures to the laser device other than those specified herein Allow only HP authorized service technicians to repair the laser device Certification and Classification Information This product contains a laser internal to the Optical Link Module OLM for connection to the Fiber communications port In the USA the OLM is certified as a Class 1 laser product conforming to the requirements contained in the Department of Health and Human Services DHHS regulation 21 CFR Subchapter J The certification is indicated by a label on the plastic OLM housing Outside the USA the OLM is certified as a Class 1 laser product conforming to the requirements contained in IEC 825 1 1993 and EN 60825 1 1994 including Amendment 11 1996 The OLM includes the following certifications m UL Recognized Component USA m CSA Certified Component Canada m TUV Certified Component European Union m CB Certificate Worldwide The following figure shows the Class 1 information label that appears on the metal cover of the OLM housing CLASS 1 LASER PRODUCT LASER KLASSE 1 58 AB232A PCI X Host Bus Adapter Installation Guide Electrostatic Discharge To prevent damaging the system you must take precautions when setting up the system or when handling parts A discharge of static electricity from a finger or other conductor may damage system adapters or
31. m Drive Parameters View information about device driver parameters that are maintained in the Windows NT registry m Persistent Binding View and manage persistent binding for the adapter and LUN mapping and masking for devices in your SAN m Link Statistics View statistics about the arbitrated loop of the selected HBA m Status and Counters View status and counters for bytes frames sequences exchanges and so on 4 Expand the category list and choose Firmware Maintenance 5 Click Download 6 Locate the new upgrade file 7 Click Open Note The new software is transferred to the HBA 8 Expand the category list and choose Adapter Revision Levels 9 Verify that the new firmware revision is shown AB232A PCI X Host Bus Adapter Installation Guide 39 Diagnostic and Configuration Utilities Modify Diagnostic Driver Parameters in the Windows Registry This screen provides information about device driver parameters that are maintained in the Windows registry and allows you to modify those values Caution Do not modify the registry parameters unless specifically instructed to do so by support personnel Modifying registry parameters can result in an unstable SAN The data display lists all available device driver parameters along with the current minimum maximum and default values Parameters that have their value specified in the system registry are denoted with either a G or an L in the left mos
32. m electrical C shock remove all power cords to completely disconnect power from the power supplies and systems N 2 Any product or assembly marked with these symbols indicates that the component exceeds the recommended weight for one individual to handle safely WARNING To reduce the risk of personal injury or damage to the equipment observe local occupational health and safety requirements and guidelines for manually handling material Getting Help If you still have a question after reading this guide contact an HP authorized service provider or access our website htto www hp com HP Technical Support Telephone numbers for worldwide technical support are listed on the HP website http www hp com support From this website select the country of origin Note For continuous quality improvement calls may be recorded or monitored Be sure to have the following information available before calling Technical support registration number if applicable Product serial numbers Product model names and numbers Applicable error messages Operating system type and revision level Detailed specific questions AB232A PCI X Host Bus Adapter Installation Guide 11 About this Guide HP Storage Website The HP website has the latest information on this product as well as the latest drivers Access storage at http h18006 www hp com storage saninfrastructure html From this website select
33. n Utilities on page 37 does not automatically load HP recommends that after loading the HBA driver you install LpUtilNt as follows 1 Browseto the LighPulse folder on the Smart Setup CD ROM or to one downloaded from the web site if it is more recent 2 Double click cp00xxxx exe Note Refer to the following website for the information about this Smart Component s final version number http h18000 www hp com storage saninfrastructure html 3 Follow the installation wizard instructions 4 After the installation completes you can start the LightPulse Utility by choosing Start gt Programs gt LpUtilNt AB232A PCI X Host Bus Adapter Installation Guide 27 Installing the SCSI Miniport Driver 28 AB232A PCI X Host Bus Adapter Installation Guide Troubleshooting The Power On Self Test POST and the Windows Event Viewer are utilities you can use for troubleshooting the HBA This chapter explains the use of these utilities in the event of an HBA problem AB232A PCI X Host Bus Adapter Installation Guide 29 Troubleshooting POST Conditions and Results Table 4 lists the HBA LED states with descriptions of each The position of the POST LED indicators is defined in Figure 1 on page 15 and Table 3 on page 22 of this guide If the LEDs indicate a failure during POST 1 Make sure that the HBA is seated firmly in the PCI slot 2 Verify that the fiber cable connection to the HBA is secure Table 4 Norm
34. ny electronic devices including computers generate RF energy incidental to their intended function and are therefore covered by these rules These rules place computers and related peripheral devices into two classes A and B depending upon their intended installation Class A devices are those that may reasonably be expected to be installed in a business or commercial environment Class B devices are those that may reasonably be expected to be installed in a residential environment for example personal computers The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user The rating label on the device shows the classification A or B of the equipment Class B devices have an FCC logo or FCC ID on the label Class A devices do not have an FCC logo or ID on the label After the class of the device is determined refer to the corresponding statement in the sections below Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to
35. on Text set off in this manner indicates that failure to follow directions IN could result in damage to equipment or data Note Text set off in this manner presents commentary sidelights or interesting points of information Equipment Symbols The following equipment symbols may be found on hardware for which this guide pertains They have the following meanings Any enclosed surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards Enclosed area contains no operator serviceable parts WARNING To reduce the risk of personal injury from electrical shock hazards do not open this enclosure Any RJ 45 receptacle marked with these symbols indicates a network interface connection WARNING To reduce the risk of electrical shock fire or damage to the equipment do not plug telephone or telecommunications connectors into this receptacle Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component Contact with this surface could result in injury WARNING To reduce the risk of personal injury from a hot component allow the surface to cool before touching 10 AB232A PCI X Host Bus Adapter Installation Guide About this Guide Power supplies or systems marked with these symbols indicate the presence of multiple sources of power Sagre Sagre WARNING To reduce the risk of personal injury fro
36. ooting Table 7 Parameter Error Values Valid only when CmdStat 0x3 Continued 0x12 Offset Explanation Further Information 0x16 IOERR_ABORT_REQUESTED 0x17 IOERR_RECEIVE_BUFFER_ TIMEOUT 0x18 IOERR_LOOP_OPEN_FAILURE FC_AL target not responding Received our own transmitted frame back Port may be bypassed by a hub onc _ TOERFLOORRUPTED Re 0x27 IOERR_RESERVED 0x28 IOERR_LINK_BUFFER SHORTAGE 0x29 IOERR_RCV_XRIBUF_WAITING 0x25 IOERR_ABORT_MULTI_ REQUESTED 36 AB232A PCI X Host Bus Adapter Installation Guide Diagnostic and Configuration Utilities This chapter contains instructions for using the LightPulse Utility LpUtilNt a Windows based graphical user interface Use this utility to update firmware BIOS view registry parameters perform persistent binding operations on selected targets and obtain specific information about all HBAs installed in the server AB232A PCI X Host Bus Adapter Installation Guide 37 Diagnostic and Configuration Utilities Using LightPulse Utility The LightPulse Utility LpUtilNt is an HBA utility that lets you m View HBA parameters m Modify driver parameters in the Windows registry The Original Equipment Manufacturer OEM setup file provided in the software kit sets these parameters The Fibre Channel setup file that comes with the platform kit modifies these parameters The resulting parameter settings provide the optimal setting for your configurations Note th
37. orized reseller install the part Note For more information on static electricity or for assistance with product installation contact your HP authorized reseller 60 AB232A PCI X Host Bus Adapter Installation Guide A AB232A host bus adapter see HBAs Arbitrated Loop Physical Addresses AL_PA table of 44 audience 8 authorized reseller HP 12 C cables FCC compliance statement 53 Canadian Notice Avis Canadien Regulatory Compliance notices 54 CE marking 55 CmdStat values 34 configuration guidelines for HBAs 23 conventions document 9 cp003654 exe 27 cp003667 exe 26 D declaration of conformity 52 diagram HBAs 15 document conventions 9 driver parameters table of 41 drivers installing 26 updating 26 electrostatic discharge 59 equipment symbols 10 European Union notice 55 AB232A PCI X Host Bus Adapter Installation Guide F FCC class A compliance notice 52 compliance statement cables 53 Federal Communications Commission FCC notice 52 flash ROM updating parameters in 48 G getting help 11 grounding methods 60 H HBAs configuration guidelines 23 diagram description 15 installation overview 17 installation procedure 20 installation requirements 18 peformance specifications 16 POST LED results 30 product description 13 recording reference numbers 19 restarting 48 verifying installation 22 viewing parameters 38 help obtaining 11 HP authorized reseller 12 storage website
38. ses AL PA you can set Table 9 AL PA Values Set Up Persistent Binding The persistent binding feature allows you to control the devices that are to be presented to the system The Miniport driver detects all devices attached to the HBAs Global automapping assigns a binding type target ID SCSI bus and SCSI ID to the device The binding type SCSI bus and SCSI ID may change when the system is rebooted When persistent binding is applied to one of these targets the binding type SCSI bus and SCSI ID remain the same whether the system is rebooted or whether Global Automap All Targets is subsequently disabled enabled by default The binding information is permanent because it is stored in the Windows registry The driver refers to the binding information at bootup 44 AB232A PCI X Host Bus Adapter Installation Guide Diagnostic and Configuration Utilities Persistent binding permanently maps a device to the following m Binding type World Wide Port Name WWPN World Wide Node Name WWNN or a Destination Identifier D ID SCSI bus SCSI ID Prerequisites Installed Miniport driver with the adjunct driver Installed LightPulse Utility Global Automap All Targets is enabled Global Automap All Targets is enabled or disabled from the Global Automap window Setting Up Persistent Binding From the LightPulse Utility Main menu screen 1 Choose the desired HBA 2 Expand the category list and choose Persistent Binding 3
39. t column of the screen The G indicates that the value is set in the global registry entry which applies to all HBAs that do not have a local registry entry The L indicates that the value is set in a registry entry specific to the selected HBA which overrides the value settings in the global entry Modify the Driver Parameters From the LightPulse Utility Main menu screen 1 Choose the desired HBA 2 Expand the category list and choose Driver Parameters 3 Double click a Parameter Name 4 Enter the desired value in the New Value field 5 Choose the Permanent or Global checkbox m Choose Permanent to cause the new value to be written to the system registry If Permanent is not selected the parameter reverts to its default value when the driver is reset m Choose Global to change the global registry entry Otherwise the change is made to the HBA specific registry entry 40 AB232A PCI X Host Bus Adapter Installation Guide Diagnostic and Configuration Utilities Table 8 lists the current parameters that you can set Table 8 Drive Parameters Parameter Description AbortStatus Oxn Values from 0x00 OxFF Controls NT SRB error status for general Abort conditions Default SRB_STATUS_BUS_RESET 0x0E which will not cause the current NT class driver to throttle down I O performance after four of these errors have been received on a per LUN basis ALTOV n Values are in milliseconds from 1 to 15 Default 15 ARBTOV
40. the appropriate product or solution HP Authorized Reseller For the name of your nearest HP authorized reseller m Inthe United States call 1 800 345 1518 m In Canada call 1 800 263 5868 m Elsewhere see the HP website for locations and telephone numbers http www hp com 12 AB232A PCI X Host Bus Adapter Installation Guide Adapter Features This introduction to the AB232A PCI X Host Bus Adapter HBA includes m Product Description page 14 m Performance Specifications page 16 AB232A PCI X Host Bus Adapter Installation Guide 13 Adapter Features Product Description The AB232A HBA has the following characteristics m Robust suite of software supporting Windows Server 2003 Enterprise Edition 64 bit version Optical small form factor LC interface LC Fibre connector Embedded optical shortwave laser multi mode Fibre Channel interface AB232A is designed using a single custom Application Specific Integrated Circuit ASIC The custom ASIC implements a very high performance multiclass multiprotocol Fibre Channel host adapter with a 64 bit PCI X bus connection 66 100 133MHz PCI X 1 0a compatibility AB232A has a 266MIPs onboard processor an embedded 1GB 2GB SERDES and a high performance unified QDR SRAM 14 AB232A PCI X Host Bus Adapter Installation Guide Adapter Features Figure 1 illustrates the AB232A HBA Figure 1 AB232A HBA m Table 2 describes the AB232A HBA Table 2 AB232A HBA Di

Download Pdf Manuals

image

Related Search

Related Contents

操舵機    Istruzioni per l`uso  PSM300 Personal Monitor System User Guide (Portuguese)  9183/9184  Anleitung - Telefon.de  Sangean Digital Atomic Clock Radio RCR-1  Série PB287 Moniteur LCD Guide de l`utilisateur  。T。 ポリバス施工説明書    

Copyright © All rights reserved.
Failed to retrieve file