1. HOOVER A i a c 6 E Q u A qu Index Important Safeguards 2 Carton Contents 3 Air Purifier Description 3 Assembly unnsennnnennnennnnnennenennnennnennn 4 How to Use 4 Maintenance 5 A eee 6 If You Have a Problem 6 7 Warranty 7 Replacement Parts 7 2 2003 The Hoover Company Fill in and retain The model and serial number are located on the back of the air purifier For your personal records please enter the COMPLETE model and serial number in the spaces provided and retain this information Your air purifier is model and has serial number It is suggested that you attach your sales receipt to this owner s manual Verification of date of purchase may be required for warranty service of your SilentAirg product important Safeguards When using an electrical appliance always follow basic precautions including the following READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE m Wa rn I ng To reduce the risk of electric shock Use indoors only Do not remove the back cover of the air purifier Doing so is dangerous and will void the warranty of your air purifier Do not operate air purifier with front cover removed e Keep the air purifier out of the reach of children or invalids The use of an extension cord is not recommended e Turn off all con
2. e Plug air purifier and other electrical equipment into separate outlets Problem Static sound coming from air purifier e New collection sheet e Normal condition Usually disappears in 24 hours One Year Limited Warranty Standard Three Year Limited Warranty honored if warranty card is returned Optional This product is warranted to the original retail purchaser against defects in materials and workmanship for a period of one year from the date of retail purchase Three years if product warranty card is returned If this product malfunctions or fails to operate due to a defect covered by this warranty The Hoover Company or its designee will at its option repair the defective product or replace it with a new product Persons covered This warranty is extended to the original retail purchaser only and is not transferable Defects and costs covered This warranty covers the cost of parts and labor for the repair of defects in materials and workmanship occurring under normal use of the product and shipping charges for the return of the repaired product to the purchaser Defects and costs not covered This warranty does not cover any defect malfunction or failure resulting from misuse or abuse of the product accidents or the damage resulting from service or repair by anyone except The Hoover Company or its designee This warranty does not cover the cost of repair by a non authorized service center This warranty does not cover shippi
3. Air purifier is dirty e Disconnect from electrical outlet and clean ionization line main body and aluminum plates Figs 3 6 through 3 8 e Replace collection sheet Problem Strong ozone odor e lonization level set too high e Set ionization control to a lower setting e Collection sheet and or purifier is dirty e Disconnect from electrical outlet and clean ionization line main body and aluminum plates Figs 3 6 through 3 8 Replace collection sheet To replace ionization line slip the ring at one end over the hook Gently stretch the line holding the opposite end to place the other ring over the opposite hook Replace front cover Service To obtain approved service call the Hoover SilentAir Customer Service Center at 1 800 473 8520 OR Visit our website at www silentair com Problem Light emitted from air purifier Common condition caused by static electricity No action reguired Will not harm air purifier Problem Aluminum plates discolored e Occurs over time under normal operation e Discoloration will not harm product performance Disconnect from electrical outlet ana if desired replace aluminum plates part no SAMP 2000 Problem Static interference on TV computer or stereo e Air purifier too close to other electrical eguipment e Operate air purifier at least four feet 1 2 m away from other electrical equipment e Air purifier and other electrical equipment share the same electrical outlet
4. hen handling the ionization line The line is very deli cate and could break easily if mishan dled The ionization line should be cleaned periodically for the quietest perfor mance possible Continued gt 5 Turn air purifier off and disconnect To remove ionization line from electrical outlet Grasp one end of the line and gently Remove front cover as described for stretch it to release ring I from hook replacing the collection sheet J Carefully wipe clean the ionization line C using a soft lint free cloth Remove opposite ring from hook If desired you may clean the collec tion plates H and the main body with a slightly moistened cloth Allow air purifier to dry thorougly 5 If you have a problem If your air purifier is not operating normally the cause may be easily found by reviewing the list below Problem Power light not on e Unit not firmly plugged into electrical outlet e Plug unit firmly into electrical outlet e No voltage in wall outlet e Check fuse or breaker e Front cover not secure e Check cover for proper placement Problem Collection sheet stays clean yet power is on e lonization line is loose e Disconnect from electrical outlet and check ionization line Air purifier is dirty e Disconnect from electrical outlet and clean ionization line main body and aluminum plates Figs 3 6 through 3 8 Problem Air purifier is noisy
5. ion sheet change light will now be reset Plug air purifier into electrical outlet and turn ionization control to desired setting Collection sheet When to replace The collection sheet should be changed about once a month When the collection sheet change light flashes it is time to change the sheet If particle or smoke levels in the room are high the sheet may need to be changed more frequently even ifthe collection sheet change light is not flashing Please note that the collection sheet change light is automatically reset to a new 30 day period each time the front cover is removed even ifthe collection sheet is not replaced Slide used collection sheet B up Be careful not to snag the ionization line Discard used sheet The pack of unused collection sheets stores on the back of the air purifier Slide envelope behind holding tabs During normal operation it is general ly not necessary to remove the front cover unless replacing the collection sheet The collection sheet should be changed at least once per month more often if particle or smoke levels are high What to buy To order collection sheets call 1 800 473 8520 or visit www silentair com Ask for part no DCS 2000 12 sheets per pack Carefully slide new collection sheet D UNDER ionization line C Place sheet under the four holding tabs E Cleaning removing or replacing the ioniza tion line Note Use care w
6. ng charges for the return of the defective product to the Hoover SilentAir Service Center This warranty does not cover consequential dam ages incidental damages or incidental expenses including damage to property Some states do not permit the limitation or exclusion of consequential or incidental damages so this limitation may not apply to you Warranty service If your product requires service covered by this warranty ship the product postage prepaid to Hoover SilentAir Customer Service Center 1660 17th Street Suite 120 Denver CO 80202 It is recommended that the product be insured during shipping as damage resulting from shipping is not covered by this warranty Include proof of the date of purchase Implied Warranties Any implied warranties are limited in duration up to three years from the date of retail purchase Some states do not permit limitations on the duration if implied warranties so this limitation may not apply to you For replacement parts and collection sheets call toll free 1 800 473 8520 Dielectric Collection Sheets 12 sheets set Part DCS 2000 Dielectric Collecting Plates 2 plates set Part SAMP 2000 lonization Line 1 line set Part SAIO 2000 1 HOOVER and E are trademarks of The Hoover Company SilentAir is a registered trademark of SilentAir Corporation
7. r B Collection sheet packet 1 Air Purifier Description Main body Collection sheet change light Power indicator lonization control Collection sheet Front cover Aluminum plates lonization line Holding tabs 4 So oNOVPRO OD Continued gt 3 Assembly Always disconnect cord from elec trical outlet before servicing the air purifier Grasp top corners of front cover A and pull cover off Polarized plug To reduce the risk of electric shock this appliance has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way Silent Hi 2090 air pury rer lonization control Plug cord into electrical outlet Turn ionization control A clockwise The green power light B will turn on Carefully slide one collection sheet Insert tabs E on front cover into B UNDER ionization line C slots F on purifier Rotate cover into Place sheet under the four holding place A magnetic latch G
8. trols before unplugging Always disconnect cord from electrical outlet before servicing the air purifier Do not unplug by pulling on cord To unplug grasp the plug not the cord Never handle plug or air purifier with wet hands Do not pull or carry by cord Do not use cord as a handle Do not close door on o or pull cord around sharp edges or corners Keep cord away from heated surfaces Do not use with damaged cord or plug If the air purifier is not working as it should has been dropped damaged left outdoors or dropped into water contact the HOOVER SilentAirg Customer Service Center at 1 800 473 8520 Do not operate the air purifier near a shower bathtub or sink Do not operate the air purifier in a bathroom or in a place where steam may be present Do not immerse the air purifier in water or any other liquid e Do not operate the air purifier near a stove or heater e Keep the air purifier out of direct sunlight Do not operate the air purifier where flammable gases such as oxygen natural gas or propane may be present e Do not put any object into the cover openings Save these instructions Thank you for purchasing the Hoover SilentAir 2000 The SilentAirg air purifier has been designed for simple problem free operation If you should happen to need assistance contact the Hoover SilentAir Customer Service Center 1 800 473 8520 www silentair com Carton contents A Air purifie
9. will hold tabs D located along each side of it in place the unit Where to place the air purifier 1 Place your air purifier across the room from an air conditioner or heating vent Ifthere are no vents in the room place the air purifier near a return air inlet 2 Do not place furniture or large objects directly in front of the air purifier Place the air purifier at least 8 inches 20 cm away from the wall 4 Ina bedroom place the air purifier three to four feet 1 2 m from the bed side 5 Placing the air purifier near an open window may reduce its efficiency oo lonization Control Level Set the control level according to the size of the room where you plan to use the air purifier The SilentAirg air purifier is designed to work 24 hours a day seven days a week regardless of the control level at which it is set Silk Ali 2000 air pur er COLLECTION SHEET LO 20 Collection sheet change light The collection sheet change light C reminds you that it is time to change the collection sheet Once every 30 days the light will flash red and the collection sheet should be changed See Mainte nance section How to replace Turn off air purifier and disconnect from electrical outlet Grasp top corners of front cover A and pull cover off Insert tabs F on front cover into slots G on purifier Rotate cover into place magnetic latch will hold it in place The collect