Home

Honeywell Wireless Wall Transmitter 5878 User's Manual

image

Contents

1. unique serial numbers during manufacture and each button or button combination on the unit also has a distinct loop number refer to Figure 1 that must be programmed into the control panel during installation Assign each button or button combination to one of eight individual zones and designate the Input Type as BR Button Type RF P If you are enrolling the 5878 locally with an RF Keypad refer to the keypad s Installation Instructions for programming instructions 1 When prompted enter the serial number either by Pressing and releasing the button or buttons that you are programming twice wait about 5 seconds between button activations or Manually through the keypad Notes 1 To activate the transmitter the 5878 buttons must be pressed and held for at least one half second 2 Serial 2 is one 1 digit higher than serial 1 which is printed on the rear of the transmitter Loop 4 Setup Both of the Loop 4 buttons must be enrolled in the control even if they will not be used If one or both of the loops is not being used program it as Zone Type 23 No Alarm Response Otherwise assign it to the desired zone type 2 Exit Programming Mode after programming is complete For complete details on how to program the transmitter s serial number at the control panel see the control unit s installation instructions Assigning a 5878 to a User On most control panels if the wall transmitter is used for a
2. Honeywell K14347 6 06 Rev A 5878 Wireless Wall Transmitter INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The 5878 is a six button eight loop wall mountable wireless transmitter It is intended for use only with wireless alarm systems that support 5800 series receivers Individual buttons on the transmitter may be programmed for any zone response but are typically used for arming or for home automation functions Optional function buttons are provided with the 5878 A Do not use for system disarming in an area that requires security This device supports both Standard and High Security encrypted modes The latter sends rolling code encrypted messaging to the RF receiver This device must be used with a receiver or control that supports high security mode i e 5881EN 5883 6150RF or 6160RF receiver or a LYNXR Series control panel Revision 13 1 or higher if you intend to use it in high security mode The 5878 is powered by one replaceable lithium battery de signed to provide up to four years of life For battery installation see Replacing the Battery LED SERIAL 1 SERIAL 1 LOOP 3 _ LOOP 2 eT SERIAL 1 SERIAL 1 LOOP 4 Te ml took Gus SERIAL 2 Tt N SERIAL 2 LOOP 3 LOOP 2 5878 WALL TRANSMITTER SERIAL 2 LOOP 1 AWAY 4 BUTTON LOOP 4 3 4 BUTTONS 5878 001 V1 Figure 1 5878 Button Designations PROGRAMMING The 5878 is assigned two
3. ION INSTRUCTIONS FOR THE RECEIVER CONTROL WITH WHICH THIS DEVICE IS USED FCC AND INDUSTRY CANADA STATEMENT THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES AND RSS210 OF INDUSTRY CANADA OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION THE USER SHALL NOT MAKE ANY CHANGES OR MODIFICATIONS TO THE EQUIPMENT UNLESS AUTHORIZED BY THE INSTALLATION AND SETUP GUIDE OR THE USER GUIDE Honeywell 12800 Brookprinter Place Poway CA 92064 Copyright 2006 Honeywell International Inc www honeywell com security K14347 6 06 Rev A
4. he tray as shown in Figure 2 Positive end must face up Use Maxell CR2032 Duracell DL 20325 or Varta CR2032 lithium battery only Slide the battery back into the 5878 Press any button and verify that the LED flashes A or Improper installation will result in damage to the battery NOTE POSITIVE SIDE MUST FACE UP 5878 002 VO Figure 2 Battery Replacement SPECIFICATIONS MOUNTING THE 5878 The 5878 can be mounted directly to a wall or other surface using two sided double stick tape or by using the provided back plate Mount the 5878 using the back plate as follows 1 Mount the back plate to a sturdy wall using self tapping screws supplied anchors for drywall are not supplied or two sided adhesive tape 2 Install the 5878 onto the backplate and slide it downward until the locking device engages 3 To remove the 5878 from the back plate release the locking mechanism by pushing it towards the wall and then care fully sliding the 5878 upward until it is released 5878 WALL TRANSMITTER eae en MOUNTING SCREWS 2 TYP BACK PLATE il LOCKING DEVICE WALL OR MOUNTING SURFACE 5878 003 v0 Figure 3 Installing the 5878 4 5 in 114 3mm x 2 75 in 69 85mm x 5 in 12 7mm Maxell CR2032 Duracell DL 20325 or Varta CR2032 Unit Dimensions Battery FOR WARRANTY INFORMATION AND FOR DETAILS REGARDING THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM REFER TO THE INSTALLAT
5. pt 4 To sync the second serial number of the wireless key with the receiver simultaneously press and hold the 1 2 3 and 4 buttons until the panel beeps For LYNXR Series controls proceed to step 6 5 To sync the device in High Security Mode press the 3 or 4 button ONCE and hold until the panel beeps indicating receipt Note If no beep is heard exit Go No Go mode and repeat Steps 1 5 6 Exit Go No Go mode by entering user code 1 OFF USING TWO RECEIVERS IN HIGH SECURITY MODE If the control supports two receivers and you plan to use them in the high security mode perform the following 1 Enroll the transmitters into the receivers one at a time by disconnecting Receiver 2 and enrolling as described in Activating High Security Mode above 2 Disconnect Receiver 1 reconnect Receiver 2 and repeat the enrollment procedure This process ensures proper High Security operation with both receivers Temporarily disable the receivers supervisory zones while enrolling to prevent them from going into trouble when disconnected After enrolling re enable the supervisory zones REPLACING THE BATTERY The LED will not flash during transmission if the battery is low To replace the battery perform the following steps 1 Slide out the battery tray located at the bottom of the 5878 2 Carefully remove the battery 3 Press and hold any button for at least one second 4 Insert a new battery in t
6. rming functions you must assign it to a user in order for it to operate This is accomplished through User Code programming at the control panel See the control panel s Installation and Setup Guide for specific instructions on programming User Codes If you are programming arming functions on both serial numbers each serial number must be assigned to a separate user SELECTING STANDARD OR HIGH SECURITY MODE For use with LYNXR Series controls earlier than Revision 13 1 the Standard Mode must be selected To select Standard Mode simultaneously press and hold the STAY 1 and 2 buttons for three seconds To select High Security Mode simultaneously press and hold the AWAY 1 and 2 buttons for three seconds The LED flashes green when transmitting in Standard Mode and red when transmitting in High Security Mode ACTIVATING HIGH SECURITY MODE To ensure proper functionality the 5878 must be synced to the security system 1 After selecting High Security mode put the system in Go No Go Test mode 2 To sync the transmitter with the receiver simultaneously press and hold the AWAY STAY 1 and 2 buttons until the panel beeps see Figure 1 For LYNXR Series controls proceed to step 4 Note The LYNXR Series panels will confirm the synchronization by sounding two beeps 3 To sync the device in High Security Mode press either the AWAY STAY 1 or 2 button ONCE until the panel beeps indicating recei