Honeywell TH8000 User's Manual
Contents
1. 11 12 CPH Electric auxiliary heat or electric furnaces Steam or gravity systems Hot water systems amp furnaces of 90 efficiency Gas or oil furnaces of less than 90 efficiency Other options 2 4 6 7 8 10 11 12 CPH Continued on next page 69 2389 03 HSIT9NA HSITONA Installation Guide Installer setup Setup functions Settings amp Options factory default in bold 0280 Backlight 0300 Manual Auto changeover 0310 Auto changeover deadband 0320 Temperature display 0330 Daylight savings 0340 Remote sensor 0345 Dual Fuel Heat Pump Control 0346 Dual fuel heat pump upstage to furnace timer 0347 Droop temperature 0350 Heat pump compressor lockout 0360 Heat pump auxiliary lockout 0371 Indoor Air Quality de vice on U1 U1 0372 Humidification Control 0374 Hum fan action 0379 Dehumidification Control 0380 Dehumidify with air conditioner 0383 Over cooling limit 0384 Dehumidification fan control 0386 Whole house dehumid ification lockout 69 2389 03 0 1 oo N om NO A wo no OoOOCN amp OO wW GwnrOow GOnwnrn c amp o o Backlight on for approx 8 seconds after keypress Backlight always on low intensity full bright after keypress requires 24VAC connection Manual changeover Heat Cool Off Automatic changeover Heat Cool Auto Off Heat cool temperature 3 F apart 1 5 C Other options 2 9 2 F to 9 F 1 C to 5 C Fahrenheit Celsius Auto change
2. B Changeover 20 30 Vac 0 02 0 6 A e 116 mm H x 152 mm W x 35 mm D L Heat pump reset 20 30 Vac 0 02 0 6 A U1 U1 IAQ relay 20 30 Vac 20 30 Vac 0 02 0 6 A Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 http yourhome honeywell com U S Registered Trademark Honeywell Limited Honeywell Limit e 35 Dynamic Drive Toronto Ontario M1V 429 Honeywell US Patent No 6595430 D509151 and other patents pending 2011 Honeywell International Inc 69 2389 03 M S Rev 03 11 Printed in U S A
3. TH8000 Series Installer s System test System status 1 Cooling system 0 Compressor and fan turn off 1 Compressor and fan turn on 2 Second stage compressor turns on 2 Fan system 0 Fan turns off 1 Fan turns on 3 Heating system 0 Heat and fan turn off 1 Heat turns on fan on if Function 0170 is set for heat pump or if Function 0180 is set to 1 See page 6 2 Second stage heat turns on 3 Third stage heat turns on 4 Emergency 0 Heat and fan turn off heating system 1 Heat and fan turn on CAUTION EQUIPMENT 5 Humidifier 0 Off A DAMAGE HAZARD 1 Humidifier on Compressor protection 6 Dehumidifier 0 Off is bypassed during test i 1 Dehumidifier on ing To prevent equipment 7 Ventilator 0o Off damage avoid cycling the 1 Ventilator on compressor quickly Special functions Auto Changeover Setup Function 0300 When set to Auto the thermostat automatically selects heating or cooling depending on the indoor temperature Heat and cool settings must be at least 2 degrees apart If function 0380 is set to On the heat and cool settings must be at least 5 degrees apart Remote Sensor Setup Function 0340 If an optional outdoor sensor is installed the thermostat can display the outside temperature If an optional remote indoor sensor is installed the thermostat will display the tem perature at the sensor location the internal sensor in the thermostat is not used A Discharge Air Tempera ture Sensor DATS is required to en
4. or any humidifier with its own transformer Bypass flow through humidifier or any humidifier that uses the system trans R Power 1 former U1 Humidifier relay 7 R Power 1 U1 Humidifier relay 7 U1 Field jumper R to U1 7 U1 Humidifier relay 7 Wiring guide dehumidification systems Whole house dehumidifier A C with low speed fan R Power 1 R Power 1 U1 Dehumidifier relay 7 C U1 Field jumper R to U1 7 U1 Dehumidifier relay 7 U1 Dehumidifier relay 8 Wiring guide ventilation systems Whole house powered ventilator Non powered ventilator R Power 1 R Power 1 ui Ventilator relay 7 C U1 Field jumper R to U1 7 U1 Ventilator relay 7 U1 Ventilator relay See notes below i 2 3 4 5 7 8 Power supply Provide disconnect means and overload protection as required Optional 24VAC common connection 0 B set to control as either O or B in installer setup If L terminal is used 24VAC common terminal C must be connected Heat pump reset powered continuously when thermostat is set to Em Heat system monitor when set to Heat Cool or Off Terminals are normally open dry contacts Equipment must include dehumidification terminal for low speed fan 5 69 2389 03 HSIT9NA HSITONA Installation Guide Remove tab and mount thermostat Remove tab Align pins on back of thermostat with slots in wallplate the
5. to daylight saving time Daylight saving time is turned off No remote sensor Outdoor sensor display only Outdoor sensor for control select lockouts and frost protec tion See page 11 Indoor sensor Discharge air sensor Required for Desert humidity control See page 11 Droop Control No droop control Droop control with aux heat lockout 1 hour Off Other options 0 5 1 5 2 6 8 10 12 14 16 hours 2 F 1 C Other options 2 5 2 F to 5 F 1 C to 2 5 C No heat pump compressor lockout Other options 5 60 F 15 C to 15 5 C See page 11 No heat pump auxiliary lockout Other options 5 65 F 15 C to 18 5 C See page 11 None Humidification Dehumidification Ventilation Off Humidify with no frost protection Humidify with frost protection Desert humidity control in heat off or cool DATS required Humidify only while fan is on Humidifier forces fan on Humidify only when heat it on Humidifier operates independent of fan None Air conditioning with low speed fan Whole house dehumidification No dehumidification control Thermostat controls dehumidification with air conditioner high speed fan See page 11 3 F 1 5 C Other options 1 2 1 F to 2 F 5 C to 1 C Fan turns on with dehumidifier Dehumidifier operates independent of fan Off On See page 11 See pages 11 12 Continued on next page VisionPRO TH8000 Series Installer setup Setup functions S
6. able desert humidification Adaptive Intelligent Recovery Setup Function 0530 Allows the thermostat to learn how long the furnace and air conditioner take to reach programmed temperature settings so the temperature is reached at the scheduled time Compressor Protection Setup Function 0580 Forces the compressor to wait a few minutes before restart ing to prevent damage During this time the message Wait is displayed Dehumidification control Setup Function 0380 TH8321 models monitor the indoor humidity level and automatically activate the cooling system to reduce humidity by lowering the temperature by up to 3 degrees below the current cool setting When Setup Function 0371 is set to dehumidification the U1 U1 relay can be set to control dehumidification Heat Pump Control Electric Backup Setup Functions 0350 0360 If an outdoor temperature sensor is installed select a compressor lockout temperature Function 0350 Below this temperature only electric heat operates Also select an auxiliary lockout temperature Function 0360 Above this temperature only the compressor operates Between these temperatures both heat sources operate Heat Pump Control Fossil Fuel Backup Setup Function 0345 Option 0 No Droop Control If outdoor temperature is above balance point Function 0350 only the compressor operates Below this temperature only backup heat operates Option 1 Droop Control As above but back
7. apart 3 C perature lockout Other options 90 F to 110 F 32 C to 43 5 C 0432 Ventilation low tem 10 10 F 23 5 C Settings 5 F apart 3 C perature lockout Other options 20 F to 0 F 29 C to 18 C 0500 Furnace filter 0 Off 8 365 day run time change reminder 1 10 day run time 9 30 calendar days 2 30 day run time 10 60 calendar days 3 60 day run time 11 90 calendar days 4 90 day run time 12 120 calendar days 5 120 day run time 13 180 calendar days 6 180 day run time 14 365 calendar days 7 270 day run time 0502 Furnace filter 0 Timer counts Heat amp Cool run time alert options 1 Timer counts Cool run time only 0510 Humidifier pad 0 Off change reminder 1 90 calendar days 2 180 calendar days 3 365 calendar days 0520 UV lamp change 0 Off reminder 1 1 year 2 2years Continued on next page 9 69 2389 03 HSI9NI HSITONA Installation Guide Installer setup Setup functions Settings amp Options factory default in bold 0530 Adaptive Intelligent 1 On See page 11 Recovery 0 Off 0540 Program periods 4 4program periods Wake Leave Return Sleep 2 2 program periods Wake Sleep 0580 Compressor 5 5 minute compressor off time See page 11 protection Other options 0 1 2 3 or 4 minute off time 0600 Heat temperature 90 Max heat temperature setting is 90 F 32 C range stop Other options 40 89 F 4 C to 32 C 0610 Cool temperature 50 Min cool temperature setting is 50 F 10 C range st
8. ettings amp Options factory default in bold 0390 Dehumidification Away 0 No Mode 1 Yes 0391 Dehumidification Away 0 Fan auto Mode Fan Setting 1 Fanon 2 Fan circulate 0392 Dehum Away Mode 76 Low limit temperature 76 F 24 C Low Limit Temperature Other options 70 F to 80 F 21 C to 27 C Setting 0393 Dehum away mode 85 Low limit away temperature 85 F 29 C temp setting Other options 70 F to 99 F 21 C to 37 C 0394 Dehum Away Mode 65 Away humidity level 65 Dehum Setting Other options 40 to 70 0400 Ventilation control 0 No ventilation 1 Vent on during all periods 2 Vent off during sleep period 3 Vent on during all periods with lockouts 4 Vent off during sleep period with lockouts 0401 Number of 2 Two bedrooms bedrooms Other options 1 to 6 0402 Size of home 10 1 000 square feet Other options 11 to 50 1 100 to 5 000 square feet 0403 Ventilation level 160 CFM cubic feet per minute Other options 30 to 195 CFM 0404 Max ventilation limit 50 50 ventilation limit Other options 30 to 60 or 100 P Meets ASHRAE 62 2 standard F Does not meet ASHRAE 62 2 standard 0405 Ventilation fan action 1 Ventilation on forces fan on 2 Ventilation does not force fan on 0430 Ventilation lockout 0 Off 1 Lockout for high temperatures See page 11 2 Lockout for low temperatures See page 11 3 Lockout for high and low temperatures See page 11 0431 Ventilation high tem 100 100 F 38 C Settings 5 F
9. is feature allows the thermostat to control one of the fol lowing IAQ devices whole house humidifier dehumidifier or ventilator 11 69 2389 03 HSIT9NA Installation Guide Accessories amp replacement parts Please contact your distributor to order replacement parts Outdoor temperature sensor Remote indoor temperature sensor Discharge air temperature sensor Energy recovery ventilator Heat recovery ventilator Fresh air damper Bypass flow through humidifier TrueSTEAM humidifier Cover plate Use to cover marks left by old thermostats or Part Number C7089U1006 Part Number C7189U1005 Part Number C7735A1000 Part number ER200B2006 Part number HR200B1005 Part number EARD6 Part number HE265A1007 Part number HM512W1005 Part Number 32003796 001 Specifications Temperature Ranges e Heat 40 to 90 F 4 5 to 32 C Electrical Ratings Terminal Voltage 50 60Hz Running Current e Cool 50 to 99 F 10 to 37 C W Heating 20 30 Vac 0 02 1 0A Operating Ambient Temperature P owerpile 750 mV DC 100 mA DC e 0 to 120 F 18 to 48 9 C Shipping na W2 Heating 20 30 Vac 0 02 0 6 A e 30 to 150 F 34 to 66 C Y Cooling 20 30 Vac 0 02 1 0A Operating Relative Humidity Y2 Cooling 20 30 Vac 0 02 0 6 A e 5 to 90 non condensing E Aux Auxiliary Physical Dimensions Emergency heat 20 30 Vac 0 02 1 0A e 4 9 16 H x 6 W x 1 3 8 D 0
10. lay c 24VAC common 2 1 S2 Optional outdoor remote discharge sensor U1 U1 Optional IAQ relay See notes below 1 Power supply Provide disconnect means and overload protection as required 2 Optional 24VAC common connection 6 Only works with single transformer systems 69 2389 03 VisionPRO TH8000 Series 1H 1C Heat Pump no auxiliary heat Wiring guide heat pump systems 2H 2C Heat Pump no auxiliary heat R Power 1 Y2 Compressor 2 relay 0 B Changeover valve 3 R Power 1 Y Compressor relay 0 B Changeover valve 3 G Fan relay Y Compressor 1 relay c 24VAC common 2 G Fan relay 1 S2 Optional outdoor remote discharge Cc 24VAC common 2 sensor 1 S2 Optional outdoor remote discharge U1 U1 Optional IAQ relay sensor U1 U1 Optional IAQ relay 2H 1C Heat Pump with auxiliary heat L Equipment monitor 4 5 3H 2C Heat Pump with auxiliary heat E Aux Auxiliary emergency heat relay Y2 Compressor 2 relay R Power 1 L Equipment monitor 4 5 0 B Changeover valve 3 E Aux Auxiliary Emergency heat relay Y Compressor relay R Power 1 G Fan relay 0 B Changeover valve 3 c 24VAC common 2 4 Y Compressor 1 relay 1 S2 Optional outdoor remote discharge G Fan relay sensor c 24VAC common 2 4 U1 U1 Optional IAQ relay 1 S2 Optional outdoor remote discharge sensor U1 U1 Optional IAQ relay Wiring guide humidification systems Steam humidifier
11. lplate installation 1 Separate wallplate from thermostat Grasp top and bottom of wallplate and pull to remove from thermostat 2 Mount wallplate as shown below Drill 3 16 holes for drywall Drill 7 32 holes for plaster MCR29480 Mounting screws Wall anchors MCR29481 69 2389 03 2 VisionPRO TH8000 Series HEAT PUMP CONVENTIONAL 2o00 For 24VAC primary power connect common side of transformer to C terminal HEAT PUMP CONVENTIONAI Terminal Designations Conventional Terminal Letters R System power Connect to secondary side of system transformer c Common wire from secondary side of transformer w 1st stage heat relay w2 2nd stage heat relay Y 1st stage compressor contactor Y2 2nd stage compressor contactor G Fan relay 1 S2 Optional outdoor remote discharge sensor U1 U1 Optional IAQ device MCR29723 Insert supplied batteries for primary or backup power Push excess wire back into the wall opening Plug wall opening with non flammable insulation a ial J E El 4 EA N H E MCR29724 Heat Pump Terminal Letters R System power Connect to secondary side of system transformer c Common wire from secondary side of system transformer Y 1st stage compressor contactor Y2 2nd stage compress
12. n Honeywell Installation Guide VisionPRO TH8000 Series Touch screen Programmable Thermostat This manual covers the following models e TH8321U1097 For up to 3 Heat 2 Cool heat pump or up to 2 Heat 2 Cool conventional systems with dehumidification humidification or ventilation Pull thermostat from wallplate and turn over to find model number Must be installed by a trained experienced technician e Read these instructions carefully Failure to follow these instructions can damage the product or cause a hazardous condition CAUTION ELECTRICAL HAZARD A Can cause electrical shock or equipment damage Disconnect power before beginning installation MERCURY NOTICE A If this product is replacing a control that contains mercury in a sealed tube do not place the old control in the trash Contact your local waste management authority for instructions regarding recycling and proper disposal This thermostat contains a Lithium battery which may contain Perchlorate material Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate Need Help For assistance with this product please visit http customer honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 U S Registered Trademark US Patent No 6595430 D509151 and other patents pending Copyright 2011 Honeywell International Inc All rights reserved 69 2389 03 HSITONA Installation Guide Wal
13. n push gently until thermostat snaps into place MCR29484 Set date and time Press AW Press AW a to set date TUE to set time WE Press AW to set month 5 Press AW a to set year ZS Ly 2010 6 00 Li LJ o a MCR29746 Press DONE to save changes Press DONE to save and exit Installer setup 1 Press SYSTEM 2 Press and hold for 5 seconds Press DONE to save amp exit 3 peas settings see p 7 9 l a4 a eS Function Setting jal 2 DONE J Press A W to change EE HOLD MCR29745 69 2389 03 6 VisionPRO TH8000 Series Installer setup Setup functions Settings amp Options factory default in bold 0120 0130 0140 0150 0160 0165 0170 0173 0180 0190 0200 0210 0220 0230 0240 0250 0260 Year first two digits Year second two digits Month Date Schedule format Restore energy saving System type Heat Pump Type Fan control heating Changeover valve 0 B terminal Auxiliary heat External fossil fuel kit 1st stage com pressor cycle rate 2nd stage com pressor cycle rate 1st stage heat cycle rate CPH cycles per hour 2nd stage heat cycle rate CPH 3rd stage heat cycle rate CPH 20 21 10 oa aorPwon s CCR oon aD k i Neo ow ua ow a oo Uos O0O 0 0 0 ow 2000 2099 2101 2178 2010 Other optio
14. ns 00 99 Other options 1 12 Other options 1 31 7 day programming Non programmable No Yes 1 heat 1 cool conventional 1 heat 1 cool heat pump no aux heat Heat only 2 wire systems Heat only with fan Hot water Series 20 system power to open amp close zone valves normally open zone valves Cool only 2 heat 1 cool heat pump with aux heat 2 heat 2 cool multistage conventional 2 heat 1 cool multistage conventional 1 heat 2 cool multistage conventional 2 heat 2 cool heat pump no aux heat 3 heat 2 cool heat pump with aux heat Air to Air heat pump Geothermal heat pump Gas Oil heat equipment controls heating fan Electric furnace thermostat controls heating fan 0 B terminal controls valve in cooling 0 B terminal controls valve in heating Electric backup heat Fossil fuel backup heat External fossil fuel kit controls backup heat Thermostat controls backup heat outdoor sensor required Recommended for most compressors Other options 1 2 4 5 or 6 CPH Recommended for most compressors Other options 1 2 4 5 or 6 CPH Gas or oil furnaces of less than 90 efficiency Steam or gravity systems Hot water systems amp furnaces of 90 efficiency Electric furnaces Other options 2 4 6 7 8 10 11 12 CPH Gas or oil furnaces of less than 90 efficiency Steam or gravity systems Hot water systems amp furnaces of 90 efficiency Electric furnaces Other options 2 4 6 7 8 10
15. op Other options 51 99 F 11 C to 37 C 0640 Clock format 12 12 hour time i e 3 30 pm 24 24 hour time i 15 30 0650 Extended fan 0 Off timer heat Other options Fan runs for 30 60 90 or 120 seconds after call for heat ends 0660 Extended fan 0 Off timer cool Other options Fan runs for 30 60 90 or 120 seconds after call for cool ends 0670 Keypad lock 0 Keypad unlocked fully functional 1 Partially locked access to temperature settings only 2 Fully locked 0680 Heat temperature 2 Standard temperature control recommended control 1 Choose if room is warmer than set temperature 3 Choose if room does not reach set temperature 0690 Cool temperature 2 Standard temperature control recommended control 1 Choose if room is cooler than set temperature 3 Choose if room does not reach set temperature 0700 Temperature 0 Thermostat displays actual room temperature display offset Other options 3 2 1 1 2 3 F offset 1 5 C to 1 5 C 0701 Humidity display offset 0 0 Other options 12 to 12 0710 RESET 0 No reset 1 Reset installer options amp program schedule to factory de fault only date and time settings are retained Installer system test During installer setup press W Test System repeatedly until Test appears number status littl MCR29488 Press AW to Press AW to select test change status Press DONE to terminate testing 69 2389 03 10 VisionPRO
16. or contactor E Aux Auxiliary Emergency heat relay G Fan relay L Heat pump reset powered continuously when System is set to Em Heat system monitor when set to Heat Cool or Off 0 B Changeover valve for heat pumps 1 S2 Optional outdoor remote discharge sensor U1 U1 Optional IAQ device 69 2389 03 HSITSNA Installation Guide Wiring guide conventional systems 1H 1C System 1 transformer 2H 2C System 1 transformer HSITONA R Power 1 6 Y2 Cool relay 2 w Heat relay w2 Heat relay 2 Y Compressor contactor R Power 1 6 G Fan relay w Heat relay 1 c 24VAC common 2 Y Cool relay 1 1 S2 Optional outdoor remote discharge G Fan relay sensor c 24VAC common 2 U1 U1 Optional IAQ relay 1 S2 Optional outdoor remote discharge sensor Heat Only System U1 U1 Optional IAQ relay R Power 1 w Heat relay Heat Only System With Fan c 24VAC common 2 R Power 1 6 1 S2 Optional outdoor remote discharge w Heat relay sensor G Fan relay U1 U1 Optional IAQ relay c 24VAC common 2 1 S2 Optional outdoor remote discharge Heat Only System Series 20 sensor R Series 20 valve terminal R 1 U1 U1 Optional IAQ relay w Series 20 valve terminal B Y Series 20 valve terminal W Cool Only System c 24VAC common 2 R Power 1 1 S2 Optional outdoor remote discharge Y Compressor contactor sensor G Fan relay U1 U1 Optional IAQ re
17. up heat is activated if room temperature drops to the selected droop temperature setting compressor is deactivated Option 2 Droop Control with Aux Heat lockout Compressor works only above auxiliary lockout temperature backup heat works only below balance point 2 droop between temperatures If temperature is not reached in a reasonable time set the upstage timer Function 0346 After the designated time the compressor will be deactivated and the system will switch to backup heat Ventilation Control Setup Functions 0400 0432 If the system includes a self powered ventilation unit Function 0400 the home can be ventilated on demand Ventilation can also be locked out based on high and low outdoor temperature Function 0431 amp 0432 outdoor temperature sensor required Dehumidification Away Mode Setup Functions 0390 0394 This feature is useful for homes in southern climates It allows humidity control when the the home is unoccupied for long periods during the hot humid season You can control temperature Function 0393 and dehumidification Function 0394 while away You can control humidity with a dehumidifier or a cooling system Function 0379 If a cooling system is used humidity is controlled by cooling indoor air to the Low Limit Temperature Function 0392 When the desired humidity is reached the system will maintain the temperature you select in Function 0393 Indoor Air Quality Device Setup Function 0371 Th