Honeywell Thermostat T8775A User's Manual

image

Contents

1. HEATING RELAY OR VALVE COIL COMPRESSOR CONTACTOR A power SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED AA Factory INSTALLED JUMPER M19515 Fig 4 Typical hookup of T8775C in heat cool system with single transformer COMPRESSOR CONTACTOR HEATING RELAY OR VALVE COIL Z power SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED REMOVE FACTORY INSTALLED JUMPER BETWEEN R AND RC M19517 Fig 5 Typical hookup of T8775C in heat cool system with two transformers Z power SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED AA Factory INSTALLED JUMPER Ause A JUMPER WIRE NOT SUPPLIED TO CONNECT W TO Y Nuse EITHER O OR B FOR HEAT PUMP CHANGEOVER M19516 Fig 6 Typical hookup of T8775C in single stage heat pump system T8775A C THE DIGITAL ROUND NON PROGRAMMABLE THERMOSTATS CUSTOMIZE THERMOSTAT Setting Fuel Switch T8775C only The fuel switch is preset at the factory in the F position See Fig 7 This is the correct setting for gas or oil systems If the T8775C is being installed on an electric heat system or a heat pump set the switch to the E position The E setting allows the fan to turn on immediately with the heating equipment in a system where the G terminal is connected es FUEL SWITCH M19497 Fig 7 Fuel switch DIP Switch To adjust the heat cycle rate or the Fahrenh
2. Voir aux Fig 2 6 les sch mas de raccordement typiques RELAIS DE CHAUFFAGE O BOBINE DE VANNE ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES Metia Fig 2 Raccordement typique du T8775A dans un syst me de chauffage seulement 69 1677EF 1 2 RELAIS DE CHAUFFAGE OU BOBINE DE VANNE RELAIS DU VENTILATEUR ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES CAVALIER INSTALL EN USINE MF19514 Fig 3 Raccordement typique du T8775C dans un syst me de chauffage seulement avec ventilateur RELAIS DU VENTILATEUR CONTACTEUR DU COMPRESSEUR ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES CAVALIER INSTALL EN USINE RELAIS DE CHAUFFAGE O BOBINE DE VANNE MF19515 Fig 4 Raccordement typique du T8775C dans un syst me de chauffage refroidissement avec un seul transformateur THERMOSTATS RONDS NUMERIQUES NON PROGRAMMABLES THE DIGITAL ROUND T8775A C CONTACTEUR DU COMPRESSEUR RELAIS DE VENTILATEUR RELAIS DE CHAUFFAGE OU BOBINE DE VANNE Z ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES LA ENLEVER LE CAVALIER INSTALL EN USINE ENTRE R ET Rc MF19517 Fig 5 Raccordement typique du T8775C dans un syst me de chauffage refro
3. 4 C 32 C 40 F 90 F et en mode refroidissement de 7 C 37 C 45 F 99 F Chauffage 1 D placer le s lecteur du syst me Heat et le s lecteur du ventilateur Auto T8775C seulement 2 R gler le point de consigne de la temp ra ture quelques degr s au dessus de la temp rature ambiante 3 Une flamme appara tra et le syst me de chauffage devrait se mettre en marche 4 R gler le point de consigne de la temp ra ture quelques degr s au dessous de la temp rature ambiante 5 La flamme dispara tra et le syst me de chauffage devrait arr ter Refroidissement T8775C seulement MISE EN GARDE Risque d aux basses temp ratures Le fonctionnement du syst me de refroidissement lorsque la temp rature ext rieure est trop basse peut endommager le compresseur Ne pas faire fonctionner le syst me en mode refroidissement si la temp rature ext rieure est inf rieure 10 C 50 F Lire les recommandations du fabricant REMARQUE Si un appel de refroidissement est effectu moins de cinq minutes apr s l arr t du compresseur ou s il y a coupure d alimentation lorsque le compresseur est en marche le thermostat passera en mode tem porisation pendant cinq minutes Cette temporisation a bout but de prot ger le compresseur L ic ne flocon de neige de clignotera pen dant ce d lai 1 D placer le s lecteur du syst me Cool et le s lecteur du ventilateur A
4. air circulation at average temperature Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in corners hot or cold air from ducts radiant heat from the sun or appliances concealed pipes and chimneys unheated uncooled areas such as an outside wall behind the thermostat Mounting Wallplate to Wall Mount the T8775A C wallplate with the screws provided See Fig 1 WALL ANCHORS 2 WALL PLATE M19499 RECU KR j WIRING HOLE 1 INCH SCREW 2 N when USING WALL ANCHORS DRILL 3 16 IN HOLES FOR DRYWALL 7 32 IN HOLES FOR PLASTER Fig 1 Mounting wallplate to wall 69 1677EF 1 T8775A C THE DIGITAL ROUND NON PROGRAMMABLE THERMOSTATS Wiring IMPORTANT Use 18 gauge wire to wire the T8775A C Thermostats All wiring must comply with local electrical codes and ordinances Disconnect the power supply to prevent electrical shock or equipment damage Refer to Fig 2 through 6 for typical wiring hookups HEATING RELAY OR VALVE COIL POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED M19513 Fig 2 Typical hookup of T8775A in a heat only system HEATING RELAY OR VALVE COIL Z power SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED FACTORY INSTALLED JUMPER M19514 Fig 3 Typical hookup of T8775C in heat only system with fan 69 1677EF 1 2
5. un tage Ils comprennent un thermostat une plaque de commutation pour le c blage et le montage du thermostat des vis de montage des chevilles d ancrage et une r sistance 4074 FAB Gf AVIS DE RECYCLAGE Si le pr sent thermostat remplace un thermostat contenant du mercure dans une ampoule scell e ne pas jeter l ancien thermostat la poubelle Communiquer avec le service d enl vement des d chets de la municipalit pour savoir comment recycler ce type de thermostat et comment en disposer INSTALLATION Avant d installer ce produit 1 Lire attentivement les pr sentes instructions Le fait de ne pas les suivre pourrait con stituer un danger ou endommager le produit 2 V rifier les caract ristiques nominales sp ci fi es dans les instructions et celles indiqu es sur le produit pour s assurer que celui ci con vient l usage pr vu 3 L installateur doit tre un technicien d exp ri ence ayant re u une formation pertinente 4 Une fois l installation termin e v rifier le fonctionnement du produit en suivant les pr sentes instructions Marque de commerce d pos e aux U Brevets en instance 2004 Honeywell International Inc Tous droits r serv s NOTICE D INSTALLATION MISE EN GARDE Risque de choc lectrique ou de dommages mat riels Peut causer des blessures par choc lectrique ou provoquer un court circuit Couper l alimentation avant d installer ce produit Ch
6. CALLED FOR HEATING OR COOLING j DIGITAL DISPLAY DISPLAYS ROOM OR SET TEMPERATURE BACKLIGHT BUTTON Je WALL PLATE FAN SWITCH 18775C ONLY SELECTS ON AUTO ROOM TEMPERATURE INDICATOR SHOWS THAT THE CURRENT ROOM TEMPERATURE IS DISPLAYED TEMPERATURE SETTING INDICATOR SHOWS THAT THE CURRENT TEMPERATURE SETPOINT IS DISPLAYED DIAL DISPLAYS AND ADJUSTS TEMPERATURE SETPOINT TURNS BACKLIGHT ON M19520 Fig 10 T8775 Thermostat features and operation SYSTEM Switch Heat The thermostat controls the heating system Off Both heating and cooling systems are off Cool The thermostat controls the cooling system FAN Switch Auto The fan only runs with the heating and cooling system On The fan runs continuously Use for improved air circulation CHECKOUT NOTE Temperature setpoint range is 40 F to 90 F 4 C to 32 C in heating and 45 F to 99 F 7 C to 37 C in cooling Heating 1 Slide the SYSTEM switch to Heat and the FAN switch to Auto T8775C only 2 Raise the temperature setpoint several degrees above the room temperature 3 A flame A will appear in the display and the heat should turn on 4 Lower the temperature setpoint below the room temperature 5 The flame A will disappear from the display and the heat should turn off Cooling T8775C only CAUTION Low Temperature Hazard Operating at too low of an outdoor temperature may cause compressor damage Do not op
7. EURS MF19567 Fig 8 Microrupteurs R glage des cycles de chauffage R gler les cycles de chauffage a l aide des microrupteurs 1 et 2 Voir le Tableau 1 Tableau 1 Cycles de chauffage Tableau 2 Affichage de la temp rature Affichage en Celsius ou Fahrenheit Fahrenheit r gl en usine Microrupteur 3 Off Celsius On Cycles Micro Micro Syst me de par rupteur rupteur chauffage heure 1 2 Vapeur gravit 1 On On Air chaud haute 3 Off On efficacit efficacit 90 eau chaude pompe a chaleur Air chaud au gazou 6 Off Off mazout r glage en usine Air chaud lectrique 9 On Off Chaleur rayonnante V rifier les cycles dans les planchers recommand s aupr s du fabricant R glage en degr s Celsius ou Fahrenheit Choisir l affichage de temp rature d sir l aide du microrupteur 3 Voir le Tableau 2 69 1677EF 1 Montage du thermostat sur une plaque de commutation RENTRER LES PATTES DE LA PARTIE INFERIEURE DU THERMOSTAT DANS LES OUVERTURES DE LA PLAQUE DE COMMUTATION APPUYER SUR LA PARTIE SUP RIEURE DU BO TIER POUR LES FIXER EN PLACE MF19498 Fig 9 Montage du thermostat sur une plaque de commutation FONCTIONNEMENT R glage des s lecteurs du syst me et du ventilateur T8775C seulement Le r glage du fonctionnement du syst me et du ventilateur se fait manuellement l aide des s le
8. Honeywell T8775A C The Digital Round Non Programmable Thermostats The T8775A C Thermostats provide single stage temperature control for 24V systems The T8775A C models include a thermostat wallplate for wiring and mounting thermostat mounting screws wall anchors and a 4074 FAB resistor MERCURY NOTICE If this control is replacing a control that contains mercury in a sealed tube do not place your old control in the trash Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old control containing mercury in a sealed tube INSTALLATION ae Installing this Product Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced ser vice technician 4 After installation is complete check out prod uct operation as provided in these instruc tions CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power supply before installation U S Registered Trademark Patents Pending 2004 Honeywell International Inc All Rights Reserved INSTALLATION INSTRUCTIONS Location Install the thermostat about 5 ft 1 5m above the floor in an area with good
9. cteurs situ s dans la partie sup rieure du thermostat Voir la Fig 10 THERMOSTATS RONDS NUMERIQUES NON PROGRAMMABLES THE DIGITAL ROUND T8775A C SELECTEUR DU SYSTEME T8775C SEULEMENT SELECTION DE COOL OFF OU HEAT VOYANTS INDIQUANT UN APPEL DE CHALEUR OU DE REFROIDISSEMENT DU THERMOSTAT AFFICHAGE NUM RIQUE AFFICHAGE DE LA TEMP RATURE AMBIANTE OU DU POINT DE CONSIGNE BOUTON DE R TRO CLAIRAGE PLAQUE DE COMMUTATION S LECTEUR DU VENTILATEUR 18775C SEULEMENT S LECTION DE ON OU AUTO VOYANT DE TEMP RATURE AMBIANTE INDIQUE QUE LA TEMP RATURE AMBIANTE ACTUELLE EST AFFICH E VOYANT DU POINT DE CONSIGNE INDIQUE QUE LE POINT DE CONSIGNE ACTUEL DE LA TEMP RATURE EST AFFICH CADRAN AFFICHAGE ET R GLAGE DU POINT DE CONSIGNE OU RETROECLAIRAGE MF19520 Fig 10 Thermostat T8775 caract ristiques et fonctionnement S lecteur du syst me Heat Le thermostat commande le syst me de chauffage Off Les syst mes de chauffage et de refroidissement sont arr t s Cool Le thermostat commande le syst me de refroidissement S lecteur du ventilateur Auto Le ventilateur fonctionne seulement lorsque le syst me de chauffage et de refroidissement est en marche On Le ventilateur fonctionne de fa on con tinue Ce r glage assure une meilleure circulation de l air V RIFICATION REMARQUE En mode chauffage la gamme de point de consigne est de
10. eit Celsius indication locate DIP switch 1 2 and 3 on the back of the thermostat See Fig 8 7 BACK OF THERMOSTAT m9567 Fig 8 DIP switch Set Heat Cycle Rate Use DIP switches 1 and 2 to set the heat cycle rate See Table 1 Table 1 Heat Cycle Rate Cycles DIP DIP Per Switch Switch Heating System Hour 1 2 Steam Gravity 1 On On High Efficiency Warm Air 3 Off On 90 efficiency Hot Water Heat Pump Gas or Oil Warm Air factory 6 Off Off setting Electric Warm Air 9 On Off In Floor Radiant Heat Check with manufacturer for recommended cycle rate Fahrenheit Celsius Indication Use DIP switch 3 to set the desired temperature indication See Table 2 Table 2 Temperature Indication Fahrenheit Celsius Display DIP Switch 3 Fahrenheit factory setting Off Celsius On Mounting Thermostat to Wallplate ENGAGE TABS AT BOTTOM OF THERMOSTAT AND WALL PLATE PRESS UPPER EDGE OF CASE TO LATCH M19498 Fig 9 Mounting thermostat to wallplate OPERATION Setting SYSTEM and FAN Switches T8775C only System and fan settings are controlled manually by using the switches located at the top of the thermostat See Fig 10 69 1677EF 1 T8775A C THE DIGITAL ROUND NON PROGRAMMABLE THERMOSTATS SYSTEM SWITCH 18775C ONLY SELECTS COOL OFF HEAT INDICATORS THAT SHOW THERMOSTAT HAS
11. erate cooling if outdoor temperature is below 50 F 10 C Refer to manufacturer s recommendations NOTE Ifa call for cooling is made before the com pressor has been off for five minutes or if a power interruption occurs while the com pressor is running the thermostat will go into a five minute delay to protect the com pressor The snowflake od will flash during this delay 1 Slide the SYSTEM switch to Cool and the FAN switch to Auto 2 Lower the temperature setpoint several degrees below the room temperature 3 After approximately five minutes the thermo stat will display a solid snowflake k and the cooling should turn on 4 Raise the temperature setpoint above the room temperature 5 The snowflake will disappear from the dis play and the cooling should turn off Fan 1 Slide the SYSTEM switch to Off and the FAN switch to On The fan should run continuously 2 Slide the FAN switch to Auto The fan should turn off Honeywell Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 35 Dynamic Drive Scarborough Ontario M1V 4Z9 69 1677EF 1 J S Rev 6 04 Honeywell Limited Honeywell Limit e Printed in Hungary www honeywell com yourhome Honeywell Thermostats ronds num riques non programmables The Digital Round T8775A C Les thermostats T8775A et C assurent la r gulation de la temp rature dans les syst mes 24 V
12. idissement avec deux transformateurs VANNE D INVERSION DU CHAUFFAGE CONTACTEUR DU COMPRESSEUR RELAIS DU VANNE VENTILATEUR D INVERSION DU REFROIDISSEMENT A ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES A CAVALIER INSTALL EN USINE A UTILISER UN CAVALIER NON FOURNI POUR RACCORDER W ET Y A UTILISER O OU B POUR L INVERSION DE LA POMPE CHALEUR MF19516 Fig 6 Raccordement typique du T8775C dans une pompe chaleur un tage R GLAGE DU THERMOSTAT EN FONCTION DE L APPLICATION R glage du s lecteur de type d nergie T8775C seulement Le s lecteur de type d nergie est r gl en usine la position F Voir la Fig 7 C est le bon r glage pour les syst mes au gaz ou au mazout Si le T8775C est install sur un syst me de chauffage lectrique ou une pompe chaleur r gler le s lecteur aE S il est r gl E le ventilateur se mettra en marche en m me temps que l appareil de chauffage si la borne G est connect e MF19497 S LECTEUR DE TYPE D NERGIE Fig 7 S lecteur de type d nergie Microrupteurs R gler les cycles de chauffage ou l affichage de la temp rature en degr s Celsius ou Fahrenheit a l aide des microrupteurs 1 2 3 au dos du thermostat Voir la Fig 8 69 1677EF 1 THERMOSTATS RONDS NUMERIQUES NON PROGRAMMABLES THE DIGITAL ROUND T8775A C MICRORUPT
13. oix de l emplacement Installer le thermostat environ 1 5 m 5 pi au dessus du plancher dans un endroit o la circulation de l air est bonne et la temp rature est moyenne Ne pas installer le thermostat dans un endroit o les conditions suivantes peuvent nuire son bon fonctionnement courants d air ou zones sans circulation d air derri re les portes et dans les coins air chaud ou froid provenant des gaines chaleur radiante du soleil ou des appareils m nagers tuyaux et chemin es dissimul s endroits non chauff s ou non refroidis p ex mur ext rieur l arri re du thermostat Montage de la plaque de commutation Utiliser les vis fournies pour monter la plaque de commutation du T8775 A ou C Voir la Fig 1 69 1677EF 1 THERMOSTATS RONDS NUMERIQUES NON PROGRAMMABLES THE DIGITAL ROUND T8775A C CHEVILLES D ANCRAGE 2 PLAQUE DE COMMUTATION i TROU DE CABLAGE VIS 1 PO 2 DANS LE CAS D UNE INSTALLATION AVEC CHEVILLES D ANCRAGE PERCER DES TROUS DE 3 16 PO SI LE MUR EST EN PLACOPLTRE OU DE 7 32 SI LE MUR EST EN PLTRE MF19499 Fig 1 Montage de la plaque de commutation C blage IMPORTANT Utiliser un fil de calibre 18 pour effectuer le c blage des thermostats T8775A et C Le c blage doit tre conforme aux codes d lectricit et aux r glements locaux Couper l alimentation afin de pr venir les risques de choc lectrique ou de dommages mat riels
14. uto 2 R gler le point de consigne quelques degr s au dessous de la temp rature ambiante 69 1677EF 1 THERMOSTATS RONDS NUMERIQUES NON PROGRAMMABLES THE DIGITAL ROUND T8775A C 3 Au bout de cinq minutes environ un flocon de neige amp appara tra sur le thermostat Le syst me de refroidissement devrait se mettre en marche R gler le point de consigne une temp ra ture sup rieure la temp rature ambiante Le flocon de neige dispara tra et le syst me de refroidissement devrait arr ter 69 1677EF 1 6 Ventilateur 1 D placer le s lecteur du syst me Off et le s lecteur du ventilateur On Le ventilateur devrait fonctionner de fa on continue D placer le s lecteur du ventilateur Auto Le ventilateur devrait arr ter 69 1677EF 1 Honeywell Solutions de r gulation et d automatisation Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 69 1677EF 1 J S R v 6 04 Imprim au Hungary www honeywell com yourhome