Honeywell Thermostat HZ432 User's Manual
Contents
1. 24804 C7735A1000 Fig 7 Connect outdoor air temperature sensor as shown Required for dual fuel systems optional for other multistage systems C7089U1006 OUTDOOR TEMPERATURE SENSOR M28207 Fig 8 Connect equipment as shown The DS BK terminal is used with a variable speed fan Connect the DS BK ODD or DHUM terminal on the HVAC equipment to this terminal When 1 zone is calling or 25 on systems with more than 4 zones this termi nal will be de energized of 24 VAC This reduces blower speed on most variable speed blowers M24809 COMPRESSOR RELAY Fig 9 If using any wireless device connect the ABCD terminals for the wireless interface module M28193 WIRELESS ADAPTER Fig 10 Connect transformer as shown DEDICATED TRANSFORMER M24806 Fig 11 69 2198 01 4 HZ432 TrueZONE CONVENTIONAL The following diagram is an overall view of wiring for a conventional system as depicted in steps 3 9 ARD OR ZD DAMPER SPRING OPEN POWER CLOSED Rc 2 RID P wis m w2 Sh YID Y2 0 HVAC cls T 24 VOLT TRANS s R Ww w2 PET IR TUNES del 1 I FANRELAY tania cid Elec dye i Y2 O Pee E I Ya H H L1 5 1 HOT R a L2 COMPRESSOR RELAY DEDICATED TRANSFORMER C7089U1000 OUTDOOR TEMPERATURE i i SENSOR seal C7735A1000 DATS O Ear WIRELESS
2. LIS 24 VOLT TRANS C EM HEAT E AUX HEAT W2 FAN RELAY Gii E i Y css a 8 HEAT PUMP T C R HOT 46 O4 x R L2 REVERSING DEDICATED VALVE TRANSFORMER E 9 5 cab a 1 1 C7089U1006 1 2 20 OUTDOOR TEMPERATURE 1t OT SENSOR rac l otti A 9 DATS C7735A1000 DATS DATS B 2 D WIRELESS ADAPTER HEAT1 zoNE1 HEAT2 HEAT3 cooL1 ZONE COOL2 O PURGE ZONES HB 3 m v2 ZONE 4 EMERGENCY HEAT IH 0 B HOME conico CHECK OUT y ADJUST SETTING ZN ALTERNATIVELY LABELED W2 ON SOME THERMOSTATS FOR THERMOSTATS WITH SEPARATE O AND B TERMINALS ATTACH O FOR COOL CHANGEOVER VALVES AND ATTACH B FOR HEAT CHANGEOVER VALVES A IF EQUIPMENT DOES NOT HAVE SEPARATE E AND W2 TERMINALS JUMPER E TO W2 ON PANEL AND WIRE TO E MAPS Wa3dWva 1 1 L3NOZ lVISOWM3Hl 2 3NOZ W3dwva 3JNOZ 1 C MM N RRD OR MARD DAMPER POWER OPEN M4 OPEN POWER CLOSED M6 CLOSED ar o OQ6_SOSDEA X mozzam 5 x ARD OR ZD DAMPER SPRING OPEN POWER CLOSED lil IN Rc D R S E AUX Sia A 00 G Sk A ARD OR ZD DAMPER SPRING OPEN POWER CLOSED S Rc D R 2 E AUX Sa A G Sloe A B L M24794 Fig 13 Zone panel wiring
3. Read and save these instructions U S Registered Trademark Patents pending Copyright 2008 Honeywell International Inc All rights reserved HZ432 TrueZONE ACCESSORIES Table 1 Recommended Thermostats Non Programmable Programmable T87N TH5110D TH3110D TH8110U TH6110D TH4110D TH5220D TH8320U TH8321U TH6220D YTH9421C TH5220D 2H 1C only TH3210D 2H 1C only TH5320U Up to 3H 2C Wire TH5320R less TH8320U Up to 3H 2C TH8321U Up to 3H 2C TH6320U Up to 3H 2C TH6220D 2H 1C only TH4210D 2H 1C only YTH9421C TH6320R Note All versions of the model numbers listed above will work with the applications they re listed for This thermostat cannot control two stages of fossil fuel when in emergency heat mode Table 2 Recommended Dampers Type Honeywell Rectangular Damper Spring open power closed Power open power closed For recommended dampers call the Honeywell Zoning Hotline at 1 800 828 8367 Static pres sure regulat ing damper SPRD Table 3 Maximum Dampers Ambient Temp Maximum Damper VA per Zone 100 F 38 C 28 8 160 F 71 C 16 8 Use an SDCR Slave Damper Control Relay for addi tional dampers Maximum dampers per panel is limited by transformer size Ensure transformer is large enough to power the panel 10 VA and dampers Table 4 Accessories Accessory Desc
4. ADAPTER POWER ACCESSORIES SENSORS THERMOSTAT ZONE 4 m ul 5 WIE RH RC W1E CO W2 00 w3 200 m 0 0 DS BK T RHO HEAT1 o zoNE1 c HEATS COOL1 O ZONE2 o MAE o Zones o EM HEAT O o NET AZA LTI AZ2 LT1 amines EMERGENCY ones DATSHTI A B WIRELESS HOME O conico CHECK OUT ADJUST SETTING OC DO M1 RRD OR MARD DAMPER POWER OPEN M4 OPEN POWER CLOSED M6 CLOSED amp Rc i jR b em jw2z VY PO Y2 el ARD OR ZD DAMPER SPRING OPEN POWER CLOSED i Re f DR il Faje ew HQ w2 mena v2 ele ARD OR ZD DAMPER SPRING OPEN POWER CLOSED Rc DIR elc ww iQ w2 Y2 ele M28196 Fig 12 Zone panel wiring conventional 69 2198 01 Installation Guide HEAT PUMP Use the following diagram for wiring a 2 heat 1 cool heat pump with electric auxiliary heat NOTE You can use a conventional thermostat for a heat pump system however em heat can only be controlled by heat pump thermostats The diagram below shows a heat pump thermostat used with a heat pump system ARD OR ZD DAMPER SPRING OPEN POWER CLOSED Rc wt fe RIO 22 cle NET EJS k A Aux 2 E YID amp WD D AR A l
5. Disabled Multistage OT Temp MSTG OT NO YES Disabled When outdoor temperature is above OT Lockout LOCKOUT NO YES Enabled Lockout temperature locks out second or third stage only for conventional and heat pump configurations OT Balance OT BALANCE DF gt lt 50F 0 deg F 50 deg F Selects the temperature at which a dual fuel Temperature Dual Fuel TEMP 30F gt configuration will change from heat pump to fossil fuel OT Trip point for multi OT LOCKOUT DF gt lt 50F 0 deg F 50 deg F The temp that locks out second or third stage stage lockout TEMP 50F gt only for conventional and heat pump configu rations not dual fuel systems LCD Contrast Adjust LCD CONTRAST 1 gt lt 10 Contrast value 1 10 Sets LCD display contrast for ease of viewing lt 5 gt Lowest contrast is 1 highest contrast is 10 Save Changes SAVE CHANGES NO YES Disabled Saves or rejects the configuration settings NO YES Enabled Reload Defaults RELOAD NO YES Disabled Restores the panel s default configuration set DEFAULTS NO YES Enabled tings 69 2198 01 12 HZ432 TrueZONE OPERATION The HZ432 TrueZONE panel contains an LED display that communicates system and zone status The LEDs indicate the following information Much of this information as well as configuration information is listed on the label on the inside of the HZ432 cover For users who prefer French or Spanish labels they are provided in form 69
6. installation unless specified otherwise Honeywell Air Cleaners Humidifiers Ventilators Ultraviolet Treatment and Zoning Products with a date code of 0501 or later excluding replacement maintenance parts sixty 60 months from date of installation All other Honeywell indoor air quality and zoning products with a date code of 0452 or earlier twenty four 24 months from date of installation unless specified other wise Variable frequency drive devices VFD and accessories new products for thirty six 36 months and factory refurbished drives for twelve 12 months from date of installation when start up and commissioning is performed by Honeywell VFD Authorized and trained personnel All VFD warranty return products must have prior authorization Form No 87 0284 and be returned only to the VFD Service Center in Chattanooga TN MS MN and Fact Acting 2 position Direct Coupled Actuators sixty 60 months from date of installation The warranty period for all other products is twelve 12 months from date of installation If a product is defective due to workmanship or materials is removed within the applicable warranty period and is returned to Honeywell in accordance with the pro cedure described below Honeywell will at its option either repair replace or credit the customer for the purchase price of the product in accordance with the proce dure described below This warranty extends only to persons or organizations who purchase products in
7. 2198FS Cut them out and attach them to the inside of the HZ432 cover Table 6 LED Operation HEAT HEAT 2 HEAT 3 o O zone 2 190 zone HEAT 1 Solid when in heat stage 1 Blinking when DATS high limit mode has been i reached PURGE ZONES FANO HEAT 2 3 Solid when in heat stage 2 3 Blinking when stage 2 3 locked out due to DATS or OT EM HEAT O zone 4 COOL 1 Solid when in cool stage 1 Blinking when DATS low limit mode has been reached EMERGENCY HEAT COOL 2 Solid when in cool stage 2 Blinking when stage 2 locked out due to DATS M24798 PURGE Solid when in purge at power up and after a call for heat or cool Blinking when the DATS sensor has failed or the wires are shorted or Fig 20 open Will blink for 3 minutes at power up if DATS is not present FAN Solid with a call for fan EM HEAT Solid when in emergency heat mode This light does not indicate a call for heat Emergency heat will only run when both HEAT and EM HEAT are lit ZONE 1 2 Solid green when open or opening Solid red when closed or closing 3 4 Blinking amber when there is a damper or thermostat short circuit circuit breaker trip CHECKOUT To enter Checkout with the zone panel cover off press the Mode button until the Check out LED lights up Use the Adjust Setting and Next buttons to work through the checkout menu as listed below See the Configuratio
8. G CAUTION Voltage Hazard Can cause electrical shock or equipment damage Disconnect power before beginning installation Wire entire panel before applying transformer power Follow these steps for wiring all systems However wiring will vary depending on equipment For conventional sys tems refer to this page For heat pump systems see pages 6 and 7 For dual fuel systems see pages 8 and 9 Wiring must comply with applicable codes ordinances and regulations Use the following wiring diagrams to wire the zone panel to the thermostats and dampers Install thermostats using instructions provided with thermostats Connect thermostat to zone panel To connect wire to the panel strip approximately 1 4 in of insulation and push wire into terminal To release wire press the button on top of the terminal o lt 5502 M24808 The HZ432 offers many innovations for wire management and organization wires can be run behind the panel through wire channels on its sides and must be attached to a wiring anchor with a cable tie M24743 Fig 5 Install dampers using instructions provided with dampers Connect dampers to zone panel NOTE Multiple dampers can be wired in parallel ARD OR ZD DAMPER SPRING OPEN POWER CLOSED Fosse M1 COMMON M6 CLOSED eds RRD OR MARD DAMPER POWER OPEN POWER CLOSED Fig 6 M24920 3 69 2198 01 Installation Guide WIRING E DATS4 TI Connect DATS as shown 8
9. HZ432 TrueZONE Zone Panel Professional Installation Guide 69 2198 01 Installation Guide TABLE OF CONTENTS sorum ici ii ACC SSONIES f E O E 1 Mountingi iii i GL ici 2 Adla lake E A N E 3 Heat Pulp ciui ana 6 Dri e 8 Basic Configurationi il M 10 Advanced Configuration P RS 12 OperatlOri iaia 13 87 1270 eta O AA O O TE 13 Warranty csi iii 14 SPECIFICATIONS Input Ratings Voltage 18 30 VAC 50 60 Hz transformer of 40 VA or more Current Draw Zone Panel 8 5 VA max All VA specifications at 24 VAC Wiring 18 or 20 gauge solid not stranded wire 13 42 Humidity Ratings 341 5 to 90 RH non condensing D Temperature Ratings Shipping 20 to 150 F 29 to 66 Operating 40 to 165 F 40 to 74 C Dimensions Int See below N Emissions mH Complies with FCC Class part 15 requirements e so 1 86 47 24797 Fig 1 HZ432 TrueZONE panel dimensions mm Need Help For assistance with this product please visit http yourhome honeywell com or call Honeywell Zoning Hotline toll free at 1 800 828 8367
10. IN 20 minutes auto changeover timer when one zone is calling for heat and another 15 20 30 MIN 30 minutes auto changeover timer is calling for cooling DATS Enabled DISCHARGE NO YES Disabled Enables or disables DATS If Disabled the SENSOR NO YES Enabled Multistage DATS Inhibit setting is Disabled DATS High Limit DAT HIGH LIMIT 110 gt lt 180 110 deg F 180 deg High temperature limit lt 160F gt DATS Low Limit DAT LOW LIMIT 30 gt lt 60F 30 deg F 60 deg F Low temperature limit lt 40F gt Multistage DATS Inhibit DAT MSTG INHIBIT NO YES Enabled Allow panel to downstage multistage equip NO YES Disabled ment when near DATS high or low limit Dual Fuel Changeover DUALFUEL OT MULTISTG Dual Fuel Changeover by OT Temp Allow panel to changeover from heat pump to CHGOVR OT MULTISTG Dual Fuel Changeover by OT Temp fossil fuel based on outdoor temperature or multistage call allow second stage call to changeover panel to fossil fuel for a minimum of one hour when outdoor temperature is above OT balance tem perature setting Dual Fuel Mstage CHANGEOVER 15 MIN gt lt 180 MIN Sets fossil fuel changeover delay Sets number of minutes to delay fossil fuel Changeover Time DELAY 30 MIN gt time when calling for second stage heat OT Temp Enabled OT SENSOR NO YES Disabled Enables or disables outdoor temperature NO YES Enabled sensor If Disabled the Multistage OT Temp Lockout setting is
11. S HOME O CONFIGO CONFIG O CHECK OUT O MODE CHECK OUT MODE Press the Mode button the Config LED will light up BACK ADJUST SETTING NEXT BACK ADJUST SETTING NEXT M24799 M24810 Fig 17 Use the Back and Next buttons to navigate through the configuration menus Pressing Next enters the selected option for that menu item and advances to the next menu Adjust settings up or down by pressing the Adjust Setting button The flow chart below illustrates basic zone panel configuration For additional configuration see Advanced Configuration on page 12 The label on the inside cover of the HZ432 Zone Panel also con tains configuration information SYSTEM TYPE CCOMWI HERTPLIMP CONVENTIONAL HEAT PUMP DUAL FUEL OFER CHO YES HEAT STAGES COMPRESSE STAGES DUAL FUEL OPERATION YES AU HT EHRELEP DFUEL HT STAGES CHO YES Cil 2 RF ENABLED HO YES ZONES INSTALLED 4 taz A COMPRESSOR STAGES 2 STAGE 2 CONTROL ZOMEI TSTAT ZONEI TSTAT OR 3 STAGE 2 CONTROL TSTATI HEAT COOL STAGES 2 OR 37 RF rurRED HTFUMP 01 DUALFUELHTSTAGES 2 COFF OR OPTIONS AUX HEAT ENABLED YES OPTIONS TSTAT TIMER ZONES OFF OPTIONS 1 2 3 4 OPTIONS TSTAT TIMER ZONES OFF HEAT COOL STAGES 1 COMPRESSOR STAGES 1 AUX HEAT ENABLED NO OR COMPRESSOR DUAL FUEL HT STAGES 2 HEAT STAGES 3 DUAL FUEL HEAT STAGES 1 AUX HEAT ENABLED YES COMPRESSOR DUAL FUEL HT
12. STAGES 2 AUX HEAT ENABLED NO HEAT STAGES 2 OR STAGE 3 CONTROL COMPRESSOR DUAL FUEL HT STAGES 1 STAGE 3 CONTROL LTSTATI P AUX HEAT ENABLED YES COFFI OPTIONS TSTAT TIMER ZONES OFF OPTIONS TSTAT TIMER ZONES OFF ADVANCED CONFIG CHO YES SAVE CHANGES Fig 18 A WHEN ANY WIRELESS DEVICE IS USED 24812 A MAXIMUM OF 4 ZONES MAY BE CONFIGURED OPTIONS INFORMATION DISPLAYED WILL VARY BY SYSTEM TYPE CONTROL TYPE NUMBER OF ZONES AND OTHER SETTINGS 69 2198 01 10 Press the Mode button until the Wireless LED lights up The TrueZONE must be configured for wireless devices to select Wireless mode Press Next to add devices While the display alternates the Press Connect and Exit screens push the Connect button s on the wire less device s OR Follow the instructions that came with the wireless device s Press Next to exit If using more than 4 zones use the TAZ 4 Add A Zone Control Panel Follow instructions with the TAZ 4 for installation form 69 1366 Note If using a wireless device a maximum of 4 zones may be configured 11 HZ432 TrueZONE CONNECT WIRELESS DEVICES 7 WIRELESS HOME conico CHECK OUT O MODE BACK ADJUST SETTING NEXT M28194 DEVICES CADE EXIT DEVICES CUIEW ADD EXIT M28195 Fig 19 69 2198 01 Installation Guide ADVANCED CONFIGURATION Use the Adjust Setting Next and Back buttons to con
13. de DUAL FUEL Use the following diagram for wiring a dual fuel system with single stage furnace and single stage heat pump ARD OR ZD DAMPER SPRING OPEN POWER CLOSED M1 COMMON RRD OR MARD DAMPER POWER OPEN O M4 OPEN POWER CLOSED MG CLOSED ye 3 s ET E pay 8 8 DIR E S u Ei 5 Aux Y2 e IY E Yz FURNACE m os l 24 VOLT TRANS NO C R W 2y ARD OR ZD DAMPER M4 E 2 SPRING OPEN FANRELAY can POWER CLOSED el 5 g Rc Y we amp E w2 o R E zi g w3 E E HEAT PUMP LI Yi Sla HOT 16 Y2 1C R SM G Ya L amp ARD OR 20 DAMPER 3 HEAT2 ZONE NO SPRING OPEN REVERSING DEDICATED 2 HEAT 3 o zowE2 POWER CLOSED VALVE TRANSFORMER COOL ae l 2 PURGE ZONES 32 E EM HEAT O OZONE 4 2 4 7 C7089U1006 9 wie are C w2 o D OUTDOOR es 9 elc TEMPERATURE o OT EMERGENCY va 3 Aye SENSOR E OT HEAT Gi aux o Gi 6 SY DATS de al v2 DATS miu es C7735A1000 qos DATS N i B O g D conico CHECK OUTO ADJUST SETTING O YO WIRELESS ADAPTER M24796 Fig 15 Zone panel wiring dual fuel single stage furnace and single stage heat pump 69 2198 01 8 HZ432 TrueZONE DUAL FUEL Use the following diagram for wiring a dual fuel system w
14. figure the zone panel See the Configuration section on page 10 for instructions on using these buttons Menu Title LCD Menu Options LCD bottom Menu option description top line line defaults in bold Heat Fan HEAT FAN CONTROL Table 5 Advanced Configuration HVAC PANEL Fan control by HVAC In heat mode fan controlled by HVAC or turned HVAC PANEL Fan control by Panel on by panel in call for heat Stage 2 Timer STAGE 2 TIMER 5 MIN gt lt 60 MIN 5 minutes 60 minutes Number of minutes to delay before engaging 5 MIN gt second stage Stage 3 Timer STAGE 3 TIMER 5 MIN gt lt 60 MIN 5 minutes 60 minutes Number of minutes to delay before engaging 5 MIN gt third stage Purge Timer PURGE TIME 2 3 5 5 MIN 2 0 minutes Number of minutes panel will purge following 2 3 5 5 MIN 3 5 minutes call for heat or cool 2 3 5 5 MIN 5 0 minutes Purge Fan FAN IN PURGE HVAC PANEL Fan control by HVAC Fan controlled by HVAC or panel during purge HVAC PANEL Fan control by Panel Purge Dampers PURGE DAMPERS UNCHANGD OPEN Dampers Unchanged Damper position unchanged or all dampers UNCHANGD OPEN Dampers All Open open during purge Auto Changeover Delay CHANGEOVER 15 20 30 MIN 15 minutes auto changeover timer Number of minutes to delay auto changeover DELAY 15 20 30 M
15. heat pump 2 heat 1 cool with electric auxiliary heat 69 2198 01 HZ432 TrueZONE HEAT PUMP Use the following diagram for wiring a 3 heat 2 cool heat pump with electric stage 3 heat ARD OR ZD DAMPER SPRING OPEN POWER CLOSED M1 COMMON RRD OR MARD DAMPER POWER OPEN M4 OPEN POWER CLOSED M6 CLOSED eee D o lt Zmox Q0N8DSSQOSS lVLSOWHHL L3NOZ lt lt gt o x N NASNOONDSGI roo o ARD OR ZD DAMPER SPRING OPEN POWER CLOSED o N LI HOT 1 lt lt 2 x HEAT 1 ZONE 1 HEAT2 O 9 I HEAT S S ZONE 2 DEDICATED COOL2 O ZONE3 N ARD OR ZD DAMPER TRANSFORMER ANS 2 Li SPRING OPEN emHEATO ZONE4 e POWER CLOSED REVERSING lb _ 5 N O 6 C7089U1006 E OUTDOOR A EE EMERGENCY TEMPERATURE 5 SENSOR gt 2 c x lt lt N SQSPOSSDSE p o WIRELESS HOME O conrico CHECK OUT ADAPTER A ALTERNATIVELY LABELED W2 ON SOME THERMOSTATS FOR THERMOSTATS WITH SEPARATE O AND B TERMINALS ATTACH O FOR COOL CHANGEOVER VALVES AND ATTACH B FOR HEAT CHANGEOVER VALVES A IF EQUIPMENT DOES NOT HAVE SEPARATE E AND W2 TERMINALS JUMPER M24795 E TO W2 ON PANEL AND WIRE TO E Fig 14 Zone panel wiring heat pump 3 heat 2 cool with electric stage 3 heat 7 69 2198 01 Installation Gui
16. ith two stage furnace and two stage heat pump ARD OR ZD DAMPER SPRING OPEN POWER CLOSED 2 o RIO Cle EIS AUX IQ YIO Y2 D Sis FURNACE 0 lS 24 VOLT TRANS R HEAT 1 1 2 W2 FAN RELAY I Ga I Y2 Y ESE ni L1 HEAT PUMP HOT TA a 1 c R ew l L2 Yai DEDICATED TRANSFORMER Y2 SANE I C7089U1006 OUTDOOR TEMPERATURE SENSOR C7735A1000 DATS WIRELESS ADAPTER THERMOSTAT ZONE 4 EQUIPMENT POWER ACCESSORIES SENSORS WIRELESS HEAT 1 HEAT 2 HEAT 3 COOL 1 COOL 2 PURGE FAN EM HEAT ZONE 1 ZONE 2 O ZONE3 00000000 ZONE 4 EMERGENCY HEAT HOME O conrico CHECK OUT y ADJUST SETTING Oc XO IVISONY3HL 3NOZ Lia lVISOWMJHLI 2 3NOZ HadWva Auman RRD OR MARD DAMPER MI EOMMON POWER OPEN M4 OPEN POWER CLOSED M6 CLOSED e Rc D R Sfc 2 lE 2 Aux GI Y v2 els Dj oe GIL ARD OR ZD DAMPER SPRING OPEN POWER CLOSED Rc D R Sjc f AUX GI Y JI Y2 else qoe ARD OR ZD DAMPER SL SPRING OPEN POWER CLOSED Gy Re D R lE iQ AUX GI Y aJ Y2 els Dj O B GIL Fig 16 Zone panel wiring dual fuel two stage furnace and two stage heat pump 69 2198 01 Installation Guide CONFIGURATION To enter Configuration WIRELESS HOME O WIRELES
17. n section on page 10 for instructions on using these buttons Steps 3 10 cycle through heating and cooling stages and open and close dampers to verify proper operation Steps 11 14 verify thermostat operation and correct wiring This is done by making the thermostats call for heat or cool and viewing the active wires as displayed on the LCD screen Table 7 Checkout Checkout Step Line 1 display Line 2 Display Display shows OT SENSOR VAL current OT temp dynamic All zone dampers open all other relays OFF Display shows DATS YIN DAT SENSOR VAL current DATS dynamic Heat stages test TEST HEAT OFF 1 2 3 Heat turns on fan also turns on if configured for fan on in heat EM Heat stages test TEST EMERG HEAT OFF 1 2 Emergency heat turns on fan also turns on Cool stages test TEST COOL OFF 1 2 Cooling turns on fan also turns on Fan Test TEST FAN OFF ON Fan cycles on and off Damper 1 test TEST Z1 DAMPER OPEN CLOSED Cycles damper position with fan on Damper 2 test TEST Z2 DAMPER OPEN CLOSED Cycles damper position with fan on Damper 3 test TEST Z3 DAMPER OPEN CLOSED Cycles damper position with fan on Damper 4 test AIS S ION S joys TEST Z4 DAMPER OPEN CLOSED Cycles damper position with fan on View Tstat1 inputs ZONE1 STAT INPTS Displays active Tstat1 terminals o
18. r displays wire less thermostat operation Tests thermostat connection with HVAC off View Tstat2 inputs ZONE2 STAT INPTS Displays active Tstat2 terminals or displays wire less thermostat operation Tests thermostat connection with HVAC off View Tstat3 inputs ZONES STAT INPTS Displays active Tstat3 terminals or displays wire less thermostat operation Tests thermostat connection with HVAC off View Tstat4 inputs ZONE4 STAT INPTS Displays active Tstat4 terminals or displays wire less thermostat operation Tests thermostat connection with HVAC off Exit checkout mode 16 Exiting checkout mode EXIT CHECKOUT EXITING CHECKOUT 13 69 2198 01 WARRANTY Honeywell warrants the products in this catalog except those parts designated on Honeywell s price lists as not covered by this warranty to be free from defects due to workmanship or materials under normal use and service for the following warranty periods Honeywell VisionPRO Commercial VisionPRO FocusPRO PRO 4000 PRO 3000 LineVolt PRO Digital Round and Modern Round T87K N Series Thermostats with a date code of 0501 or later sixty 60 months from date of installation CommercialPRO PRO 2000 and PRO 1000 thermostats twenty four 24 months from date of installation All other Honeywell thermostats and thermo stats with a date code of 0452 or earlier twelve 12 months from date of
19. ription 40 VA transformer AT140A1042 75 VA transformer AT175A1008 Discharge Air Temperature Sensor DATS C7735A1000 Wired Outdoor Air Temperature Sensor Wireless Outdoor Air Temperature Sensor C7089U1006 hard wired C7089R1013 wireless Wireless Adapter THM4000R1000 TAZ 4 TotalZone Add A Zone Control Panel SDCR Slave Damper Control Relay Wireless Remote Control REM5000R1001 Included in HZ432K kit 69 2198 01 Installation Guide MOUNTING Mount the HZ432 TrueZONE panel near the HVAC equipment locate it on a wall stud roof truss or cold air return NOTE The HZ432 TrueZONE panel can be mounted in any orientation level it for appearance only Please refer to TrueZONE Panel Frequently Asked Questions form 50 9694 for operating details SPRD BYPASS DAMPER ZD SERIES ZONE DAMPERS DATS ALTERNATE LOCATION TrueZONE PANE MOUNTED ON RETURN DUCT TrueZONE PANEL MOUNTED ON WALL DATS AT LEAST 3 FT FROM PLENUM AIR CONDITIONER M24738 Fig 2 Attach the base to the wall stud roof truss or duct with appropriate screws not included O Separate the zone panel cover from the base and use the base as a template to drill mounting holes M24807 69 2198 01 77 Use two screws for attaching to a stud or roof truss or four screws for duct or drywall plaster installations HZ432 TrueZONE WIRIN
20. this catalog for resale The expressed warranty above constitutes the entire warranty of Honeywell with respect to the products in this catalog and IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL HONEYWELL BE RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 429 customer honeywell com Honeywell U S Registered Trademark 2008 Honeywell International Inc Printed in U S A on recycled Patents pending paper containing at least 10 69 2198 01 M S 02 08 post consumer paper fibers