Honeywell Smoke Alarm IPGSM-DP User's Manual
Contents
1. cccccccccccccesessssseceeececeeeesscssscecececeenessseseeececsesensesssaeeeeeess 8 LED Display InformatiOR irte he rte tel oed e td te e RE Ie PE TUNE 8 PowerBoost1 Module Information eeeseseseseeeeeneeen enne nee en nnne en nennen rennen nennen nnns 9 1GSM Communications Module Information esses ener en 10 RE Specifications ose te RIO PRO GV RP E EE e eM 11 IPGSM DP Specifications eese neenon EEA EAE saos tentes testes sesto t tette neos 11 Warts Diaeram 45 c ad eR UAE ES Inside of Back Cover IPGSM DP Commercial Fire Communicator Installation and Setup Guide General Information The IPGSM DP Commercial Fire Communicator henceforth referred to as IPGSM DP includes everything you need to upgrade a commercial fire system that previously reported by POTS to a system that uses the Internet as its primary reporting path and uses a GSM cellular reporting path as a backup In addition this communicator utilizes a sophisticated power module PowerBoost1 that monitors and reports AC power loss low battery and missing battery conditions Package Contents e Red Fire Cabinet and Back Plate e Antenna and Mounting Adapter e LED Display board e Cam Lock with Key e PowerBoost1 e Mounting Rails for above e Dialer Capture Module e Battery harness Hardware Bag e iG8M Communications Module e Wall Outlet Box P N K14358 e Transformer 18VAC N8167 e 50 ohm cable assembly e Ferrit
2. o BATTERY e ee c mc L T o u u amp px rU ice ve FUSE Sorra 7720P pmu POWER 9 108 VAC PROGRAMMER TE Einem PORT Teaco woe TB1 L1 2 BATTERY 1 ov in RSSI MODE GND Honeywell cal INDICATORS 7AH 5 JECP In deste MODE amp STATUS not supplied 6 ECP Out TAUPER E SWITCH zi SWITCH a 9 oH Use a Honeywell 712BNP INTERNET Yuasa NP7 12 or equivalent FLT Out CONDUIT s CONNECTIVITY maj INDICATORS gt 2 To Router Ej To Fire Panel z To Fire Panel 8 i a z NOTES e All circuits are power limited except the backup battery which is non power limited e Non power limited wiring must be separated from the power limited wiring by at least 1 4 inch e If desired use a Honeywell 955WH Tamper Switch with the 28 2 bracket FCC STATEMENT Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interferenc
3. BLINK GPRS in SLOW BLINK Module registered second use site available and low signal strength NORMAL BLINK Module registered second site available acceptable signal strength FAST BLINK Module registered second site available excellent signal strength 10 IPGSM DP Commercial Fire Communicator Installation and Setup Guide RF Specifications Transmission Transmit Receive Receive Number Channel Duplex Band Frequency Power Frequency Sensitivity of Spacing Separation MHz dBm MHz dBm Channels wuz kHz GSM 850 824 849 33 869 894 107 124 200 45 GSM 900 890 915 33 935 960 107 124 200 45 GSM 1800 1710 1785 30 1805 1880 106 374 200 95 GSM 1900 1850 1910 30 1930 1990 105 5 299 200 80 IPGSM DP Specifications ITEM SPECIFICATION Cabinet Dimensions Transformer N8167 Width 12 3 4 inches Height 14 7 8 inches Depth 3 inches Primary 120VAC 60Hz Secondary 18VAC 50VA Battery 12V 7Ah sealed lead acid type not supplied Use a Honeywell 712BNP Yuasa NP7 12 or equivalent Battery Charging Current maximum 1A Supervision The AC power backup battery IP communications and GSM communications are monitored 11 IPGSM DP Commercial Fire Communicator Installation and Setup Guide NOTES 12 Wiring Diagram The wiring diagram below is depicted for poin
4. C Dialer Capture Module TO Facility Ground CONDUIT Md iGSM Comm Module BATTERY 7AH not supplied Wiring for Grounds Power and RF IPGSM DP 001 V2 US Only IPGSM DP Commercial Fire Communicator Installation and Setup Guide STEP 5 Program the Communications Module You must use the 7720P Programming tool to program the IPGSM DP When using the 7720P Programming tool the values given below are for most installations Press the key to accept the displayed default value xxx or enter the new value and press the key for the next prompt Use the Space key to scroll through a list of options no display Connect the 7720P 7720P PROGRAMMER Press t Strt Prog Mode Y N Press Shift then Y then 4 Program Device Y N Press Shift then Y then 4 Com Path Choice IP amp GSM Press Space to scroll choices IP amp GSM IP or GSM At choice press Primary City ID Enter number 01 99 then press f Primary CS ID Enter number 01 FE then press ft Primen Sub I 2000 Enter number 0001 9999 then press Note If a Com Path Choice of IP amp GSM or IP was selected prompt 9 will appear Use DHCP Y N Y If your router is configured for DHCP press Shift then Y then press Note If D
5. HCP is not selected your router is set for a static IP prompts 10 through 13 will appear NIC IP Address 255 255 255 255 Subnet Mask 255 255 255 255 Enter choice then press Follow the prompts Enter choice then press Follow the prompts Gateway IP Address 255 255 255 255 DNS Serv IP Addr 255 255 255 255 Review Y N Enter choice then press Follow the prompts Enter choice then press Follow the prompts Enter choice then press Follow the prompts Create Password Y N Enter choice then press Follow the prompts Exit Prog Mode Y N Press Shift then Y then press DONE Note If an error in programming occurs set the factory defaults see next topic and reprogram the IPGSM DP IPGSM DP Commercial Fire Communicator Installation and Setup Guide To exit the programming mode press N in response to the Review prompt Then press Y to the Exit Prog Mode prompt Upon exiting the root file is updated to log the changes made message is displayed telling the user that this step is being executed When complete the message DONE is displayed to indicate the file was successfully uploaded Note If critical configuration changes were made such as the mode of operation the communications module will reset to ensure that the programming features are enabled If the file is not successfully uplo
6. Honeywell Commercial Fire Communicator Installation and Setup Guide IPGSM DP Commercial Fite Communicator C RADIO TROUBLE LOW BATT AC Loss AC ON Honeywen 800 08074 1 11 Rev A Contents General Mior matoi 1 5 m nud ete itm ease lation ete ade aes a Sede edd ss IS 1 Pack ge Contents eser rae ccadbesssuadeceeesdaceez se leases cas ed bust ete tarde eser aaa aaka eter ese ee Red dT 1 Compatible Fir Panels eda eere e rese egeo ego eere rede renun ESE 1 Operation cioe ld neil INDIEN eese alten ee d ND 1 IG TCIEInGI NR E tice dea deteous ded neat udces ANAA 1 UT Compliance eben abi bos iet teo RR 1 STEP 1 Activate the SIM and Setup the Customer Account sseeeeeee 2 STEP 2 Register the Communications Module with AlarmNet esee 2 STEP 3 Determine the Signal Strength and Select a Location esee 3 STEP 4 Mount and Wire sssssssseseeeeeeeneee enne rnnr Eseia nnna srna EEE nennen nnns enne 3 STEP 5 Program the Communications Module seseeeeeeeene e eene 6 STEP 6 Configure the Fire Panel sese en ee etn nnne enn 7 STEP 7 Test the System ccccsssssssssscccesccsessnsnsecscesecsensrsseescesecsseseessceecesecsesensnseeeeesecenes 7 IPGSM DP Trouble Detection Information seesesesseeeeeee eene enne enne ennt entren 8 Dialer Capture Module Information
7. TT yellow Missing or low battery TROUBLE yellow One or more trouble conditions exist such as overload output supervision ground fault or charger failure Notes e If AC power is lost and the battery voltage falls below 10v the module s output voltage will be turned off The output power is turned back on when AC power is restored e You must use the DIP switch settings shown below LowBarrugp PowerBoostl TROUBLE LED INDICATOR p le INDICATOR C Confiure DIP switch as shown ON 12345 Switch handle white 4 E AC LED 9 oa INDICATOR X ACTIVE LED INDICATOR iPGSM COM 003 VO IPGSM DP Commercial Fire Communicator Installation and Setup Guide iGSM Communications Module Information iPGSM COM 002 V1 ON NOT registered with AlarmNet OFF Registered with AlarmNet FAST BLINK Download session with Compass in progress SLOW BLINK In unison with yellow LED registration in progress on PRIMARY POWER 9 16 5 VAC CURRENT 900mA PEAK 70mA STANDBY BATTERY BV 3 1 AHr FOR 24 Hr BACKUP ie 7720P Programmer FOC XXXXXXXXXX IC YYYYYYYYYY ON Message transmission pending QUICK PERIODIC BLINK Normal FAST BLINK Message waiting for network ACK RSSI Mode and status LEDs SLOW BLINK Idle power abnormal SLOW BLINK In unison with green LED registratration in progress Tamper Switch Mod
8. aded one of the following prompts will be displayed Follow the steps shown below until the upload is successful Display Description What to do Cannot Upload Module is not yet initialized Wait for RSSI indicator LEDs to be lit Try Again Y N_ Press Y Failed to Update Network problem or you answered N Initiate the Force Server Update Root File to Cannot Upload Try Again prompt Command by pressing the 0 key Setting Factory Defaults To reset the programming options to factory default values at the Exit Prog Mode prompt press Shift plus ESC Note setting the factory defaults will also erase any password that may have been entered Set Default Press Y to reset factory default values YN Press N to cancel this function Press Shift then Y then The Create Password prompt appears follow the prompts then exit STEP 6 Configure the Fire Panel 1 Ensure the Telco Fault on the panel is enabled Then choose a setting that is no higher than 90 seconds or as close to that as the panel allows 2 Ensure no more than 1 pause character usually a comma is programmed into the dialing string usually 2 seconds Note this is necessary since the Dialer Capture Module waits only 3 seconds after the phone number is dialed Having more than 3 seconds of pause time will cause it to think the phone number is complete and cause it to generate the high low tones at an incorrect
9. cations Module When all the reports are sent the fire panel goes on hook The IPGSM DP then transmits the messages to the central station either over the internet or the GSM network Installation UL Compliance To meet UL864 NFPA ensure the following e IPGSM DP must be installed in accordance with NFPA National Fire Protection Association standards 70 and 72 e IPGSM DP must be mounted in the same room and within 20 feet of the fire panel The wiring must be routed through conduit e PGSM DP and all equipment used for the IP connection such as the router hub modem etc shall be listed must be powered from an un switched branch circuit and be provided with appropriate standby power e IPGSM DP must use a 7AH battery not supplied to provide 24 hour backup capability IPGSM DP Commercial Fire Communicator Installation and Setup Guide STEP 1 Activate the SIM and Setup the Customer Account The communicator requires a subscriber account customer account to be setup with AlarmNet Direct This is accomplished by registering the communicator s iGSM communications module with AlarmNet Registering enables the fire panel to send reports To setup the customer account you will need to contact the central monitoring station to get account information and have access to the AlarmNet Direct website To access the AlarmNet Direct website visit https services alarmnet com AlarmNetDirect If you do not wish to use
10. e Switch ON No contact with network OFF Normal SLOW BLINK Loss of communication with the Dialer Capture Module ECP fault FAST BLINK No network contact AND loss of communi cation with the Dialer Capture Module Note If all LEDs FAST BLINK in unison with the RSSI LEDs this indicates a Hardware Error BLINKING Network collision detected Network Collision OFF Normal YELLOW ON 100 MB S link to Internet Link Speed OFF 10 MB S link to Internet GREEN ON Ethernet Link detected Ethernet Link Activity OFF No link detected GREEN FAST BLINK Transmitting Receiving Data MODULE S RECEIVED SIGNAL STRENGTH RSSI When the Mode Switch is NOT depressed LED 1 will illuminate red e The remaining LEDs indicate RSSI Received Signal Strength oll l MODULE S OPERATION MODE When the Mode Switch IS depressed LED 1 will be OFF LEDs 2 and 3 indicate the module s communication mode with the Dialer Capture Module LED 2 yellow LED 3 yellow Zone NOT USED 4204 NOT USED 2 4204 NOT USED MODULE S STATUS When the Mode Switch IS depressed LED 1 will be OFF e LEDs 4 5 and 6 indicate the module s Status LED 4 green LED 5 green LED 6 green ON Connected to ON GPRS service ON Module registered no second Internet available site available OFF Not connected OFF No GPRS service OFF Module not registered with to Internet available network carrier FAST
11. e After the IPGSM DP is installed and programmed you can register the module by clicking the Tamper Switch 3 times OR e After the IPGSM DP is installed and programmed you can register the module using the 7720P Programming tool Simply Press Shift then press Please wait for Registration SUCCESS message IPGSM DP Commercial Fire Communicator Installation and Setup Guide STEP 3 Determine the Signal Strength and Select a Location IMPORTANT Do Not mount this device outdoors RF Exposure Warning The antenna s used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in con junction with any other antenna or transmitter When choosing a suitable mounting location understand that signal strength is very important for proper operation For most installations using the supplied antenna mounting the unit as high as practical and avoiding large metal components provides adequate signal strength for proper operation You will use the iGSM Communications Module to determine signal strength in order to find a suitable mounting location Note If the SIM 1s already activated the RSSI signal strength indicators will indicate signal strength If the SIM has not been activated the firmware in the communications module enables it to communicate with the cellular network towers without the SIM being activated so tha
12. e Filter Compatible Fire Panels The IPGSM DP works with Fire Panels that use the Contact ID communication format as described in the SIA DC 05 Standard After completing the field installation verify communications with the central station is successful by sending several events Also get confirmation that these events were received Note For a fire panel that has more than 9 active partitions the first 9 partitions are reported to the central station uniquely Beyond 9 partitions only the 2nd digit of the partition is reported along with a leading zero example partition 14 is reported as 04 The installer must inform the central station of this condition Operation The IPGSM DP replaces the fire panel s POTS communications path When an event occurs the fire panel goes off hook to dial the central station The IPGSM DP detects the off hook condition and provides the fire panel with a dial tone When the fire panel detects the dial tone it begins dialing the central station The IPGSM DP considers the three second period after dialing as the number dialing has been completed After the dialing is completed the Dialer Capture Module returns a handshake to the fire panel The fire panel then sends the contact ID reports to the IPGSM DP which in turn sends a kiss off after the report is successfully received from the fire panel Within the IPGSM DP the Dialer Capture Module sends the contact ID reports over the ECP bus to the iGSM Communi
13. e in which case the user will be required to correct the interference at his own expense FCC IC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment DOCUMENTATION AND ONLINE SUPPORT For the latest documentation and online support information please go to http www security honeywell com hsc resources MyWebTech WARRANTY For the latest warranty information please go to http www security honeywell com hsc resources wa Honeywell 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 THT WAAL Copyright 2011 Honeywell International Inc 800 08074 1 11 Rev A www honeywell com security
14. es every sec PowerBoost1 and Communications Module connection is lost Note Telco ports 1 primary dialer and 2 secondary dialer may be used instead of the terminal board D 5 o E Is a Whichever connection method is used both Telco paths must be connected to the Fire Panel O O RED GREEN Telco 2 Telco 1 iPGSM COM 004 VO C Dialer Capture Module LED Display Information Panel Status LED Indicator RADIO TROUBLE Yellow ON when radio trouble is present gt O Buzzer Upon loss of AC power this will 5 beep once every 10 seconds N 5 e LOW BATTERY Yellow ON when battery is low 0 Yellow not used O AC LOSS Yellow ON when no AC is present Q AC ON Green ON when AC is present O 8 z 8 IPGSM DP Commercial Fire Communicator Installation and Setup Guide Note If a wire pulled out of the LED Board Connector Violet LED Board refer to the diagram on right and reinsert wire ensuring Black Connector the connector pin is locked in White Red Brown Yellow Gray PowerBoost1 Module Information LED Indicator STATUS AC AC power available green ACTIVE Cyclical flashing normal communications green Repetition of 3 flashes loss of communications LOW BA
15. m on the inside of the back cover of this manual for wiring and component identification 1 Remove knockouts from cabinet to accommodate the power input wires and wiring to the control panel Then mount the cabinet securely to the wall using 4 screws or bolts Use mounting screws or bolts that are suitable for the material being anchored to 2 Ensure the cabinet door lock is installed IPGSM DP Commercial Fire Communicator Installation and Setup Guide 10 11 12 13 Install the two plastic mounting rails for the LED Display board They simply snap into the back plate holes Connect the LED Display board to its connector then slide the board into the mounting rails Yellow LED and Buzzer are on top Carefully remove the packaging material that surrounds the PowerBoost1 Mount the PowerBoost1 on the three unused standoffs Use the plastic screw prevents shorting to secure the upper right corner of the PowerBoost1 and the two metal screws and lock washers to fasten the left side of the circuit board Ensure the lock washers are located between the circuit board and the head of the two metal screws Mount the Wall Outlet Box to an un switched facility power outlet and run a conduit to the cabinet In this step DO NOT plug the transformer in Route 16AWG wire from the transformer through the conduit Pass the wires through the Ferrite Filter then loop the wires back through again making a loop Connect the wires to
16. moment STEP 7 Test the System 1 Close the Wall Outlet Box then close and lock the cabinet cover 2 Refer to the fire panel s installation operation guide the testing procedure 3 Notify the monitoring station that a test will be conducted Test the system to ensure it is operating IPGSM DP Commercial Fire Communicator Installation and Setup Guide IPGSM DP Trouble Detection Information Telco 1 is used for the Fire Panel to output contact ID messages to the IPGSM DP and Telco 2 is used by the IPGSM DP to report faults to the Fire Panel If Telco 1 is not operational the Fire Panel will use Telco 2 to report events if there are no faults in the iGSM Communications module Fault Condition Indication to Fire Panel PowerBoost1 fault Telco 2 is cut iGSM Communications Module fault e Failure of one of the two Telco 2 is cut communications paths e Failure of both communications Telco 1 and 2 are cut paths Dialer Capture Module buffer is full Hang up Panel will retry giving the buffer a chance to empty Dialer Capture Module Information LED Indicator STATUS RED Steady ON Messages exist in buffer RED Flashing No messages to be sent Waiting for messages GREEN Steady ON Normal Indication GREEN Blinks every 2 sec PowerBoost1 communication problem GREEN Blinks twice every sec Communication Module connection is lost GREEN Blinks 10 tim
17. t signal strength measurements can be determined In this case you can display the signal strength by simultaneously pressing the MODE and TAMPER switches 1 For this procedure you will need a fully charged 12V battery 2 Attach the Antenna see illustration on page 5 3 Temporarily wire the battery s negative terminal to TB1 4 on the iGSM communications module then wire the battery s plus terminal to TB1 2 on the communications module Wait about one minute for the module to initialize 4 Position the assembly near a suitable mounting position and observe the RSSI display 1 M Ma un T oe 5 Look for a mounting position that yields at least 3 bars lit solid Four B K K K searsmn or five bars are better R GG TBA5 GSM O25 VO 6 Verify the signal strength remains steady for a few minutes then mark that mounting position Disconnect the battery STEP 4 Mount and Wire e For UL compliant installations refer to the topic on UL Compliance in this manual e For Dry Indoor use only e Unless otherwise specified use 18AWG e External cabinet wiring may be routed in conduit if desired This communicator comes partially assembled with all the components mounted except the Antenna LED Display board and PowerBoost1 To protect certain components on the PowerBoost1 it is shipped un mounted but fully wired Note Refer to the diagram on page 5 and to the Wiring Diagra
18. t to point electrical connection checks used for troubleshooting or component replacement It is not intended to show the physical routing of wires When replacing a wire or component ensure the wire is routed in the same manner as the original factory wire WALL OUTLET BOX K14358 TRANSFORMER N8167 Wis ANTENNA Buzzer OPTIONAL CABINET TAMPER SWITCH CABINET DOOR WHT LO BATT I LED Display RADIO BIG eo eve ev rey Buzzer TARILE PowerBoost1 aua Izox TROUBLE iu E H Low Fe B gt 5 D Bj BATT Dal 8 ESER LOW BATT E a asz LD o i8 o gas iiti a not used PERSE 8 Ferrite Filter 35 mp AC LOSS d GREEN d 8 AC ON YF i C Dialer Capture Module E A e I amp ERTH GND A C i ul MH 5 2 YEL RX Q Haee Ip RED E o s o eue e BR F E ax me le E ga BLK amp pc g ag amp N U Es OUT 3 2a Dc S o 22 To Commi AC ON GRA jour Bee Module E oc 3 8 gg STATUS m N U F rit MESSAGE BOHN NNK ONLY n
19. the AlarmNet Direct website you may call AlarmNet to setup the account just phone 800 222 6525 then select option 1 Monday Friday 8 00 am to 9 00 pm Saturday 9 00 am to 5 30 pm EST Have the following information ready e Primary City ID two digits obtained from your e Primary Subscriber ID four digits obtained monitoring station from your monitoring station e Primary Central Station ID two digits obtained e Communication Module s MAC ID and MAC from your monitoring station CRC number located on outside of box and inside of the module Note The IPGSM DP comes with a SIM Subscriber Identity Module that needs to be activated 1 To activate the SIM log into the AlarmNet Direct website and choose SIM Activation Status then enter the required information Click Activate SIM 2 Setup the customer account by choosing Program New Device GSM I enter the required information When complete click DONE STEP 2 Register the Communications Module with AlarmNet Registering the module activates the account with AlarmNet and enables the fire system s control panel to send reports There are three methods that can be used to register the communications module e Register the module by logging into AlarmNet Direct and choosing Show Programmed Devices GSM T Search for the account using the Account Information or MAC ID Under the Actions column use the pulldown menu and choose Register OR
20. the PowerBoost1 AC terminals Connect and route 16AWG insulated wire from facility power ground typically a cold water pipe to the cabinet s ground post Ensure all ground connections are tight Connect the Ethernet cable and the Telco 1 and Telco 2 lines If you choose to use an optional Cabinet Tamper Switch if the control panel supports it mount and wire it Note The Ethernet cable Telco 1 Telco 2 lines and the optional cabinet Tamper Switch if used must be run through conduit Verify the PowerBoost1 module DIP switches are configured as shown below PowerBoost1 ON 12345 Switch handle white iPGSM COM 008 VO Ensure the following e LED Display board is fully seated e All wiring terminals and connectors are tight e All wiring has been completed and secured with cable ties Install the battery not supplied Plug the power transformer in and attach the battery cable IPGSM DP Commercial Fire Communicator Installation and Setup Guide ANTENNA N NUT WASHER ANTENNA MOUNTING ADAPTER CABINET DOOR m 5 1 4 WALL OUTLET BOX K14358 TRANSFORMER N8167 Data Out O inoeeq PWR G GREEN Telco 2 Telco 1