Honeywell PRO-2200 User's Manual

image

Contents

1. le 485 Com scm 181 4 9 Good 1513 amp Er S I Two Reader Board D74 D77 lt t OO N lt T Tamper Switch In Close Position Normally when Cabinet Door Is Closed Power Fail Input 7 17 12VDC Power Supply C No Charging Input 7 Common N C No Charging N C Low Battery Input 8 DIDSDWN D78 Configuration Dip Switches 1 ONDARON Relay 5 NC Relay 5 C Relay 5 NO Relay 6 C Relay 6 NO 000000 DODO Input 8 Common Relay 6 NC Self Powered Audio Visual Alarm Indicator NO The connectors on this side of the board are not accessible when it is rack mounted C Low Battery PWR PWR DC Output PWR PWR Note For N 485 Communication Connections twist the blue pair together and use as the common use the orange pair as your data pair observing polarity Connect the external drain shield to the appropriate earth ground on one end 18 Installation Guide NOTES PRO 2200 Two Reader Module PRO22R2 Honeywell Honeywell Security amp Data Collection 2700 Blankenbaker Pkwy Suite 150 Louisville KY 40299 800 675 3364 www honeywellaccess com
2. 10mA sink max Reader data inputs TTL compatible inputs Communication RS 485 9 600 to 38 400 bps Wire requirements Power 1 twisted pair 18AWG RS 485 24AWG 4 000 feet 1 200m max 2 twisted pair with shield 120Q 23pf Belden 9842 or equivalent Alarm inputs 1 twisted pair per input 30 ohms max Outputs As required for the load Readers 6 conductors 18AWG 500 feet 150m max shield and drain Mechanical Dimension 5 5 140mm W x 9 229mm L x 1 25mm H Weight 12 oz 340g nominal Environment Temperature 0 C to 49 C operating 55 C to 85 C storage Humidity 0 to 85 RHNC 16 Installation Guide PRO 2200 Two Reader Module PRO22R2 Wiring Diagram for Connectors 1 through 7 6 Door estatus Switch EOE Egress Set Push Button Switch Input 5 Input 5 Common Input 6 Input 6 Common Input 1 1 Typical Connection Input 1 Common 2 RED Input 2 3 Input 2 Common 4 Relay 1 NO S4 Door Lock Fa suppressor Relay 1 C Z z Relay 1 NC 7 Relay 2 NO O 8 Separate _ Relay 2 C 319 Power VDC Relay 2 NC Supply Tee 10 sss sees zato RED a 5 or 12V DC Out Voltage Is Selected By Red LED 1 Jumper J2 On Board 2 a CITI 9 Data 1 Z A Weigand Data 0 Sls gt Keypad Common Sle Chassis GND input 3 assis e Inside Panel Input 3 Common _ Input 4 Input 4
3. C J E E EE LE e ER Wee ee eet ON TI ON pot OFF LEE on Jor orF_ ADDRESS 4 ESTs OH a ee eg ON e fs essi ON Default PRO 2200 Two Reader Module PRO22R2 Installation Guide 11 LED Operation Power The Reader board uses two on board LEDs D79 amp D80 to provide status information during its Power up sequence as well as normal operation DESCRIPTION Start Power up hardware setup Testing RAM Testing ROM and completing initialization LED D79 flashes 4 times after Power up is completed Power up Sequence This is the processor heart beat LED It flashes once every second A short ON time 20 duty cycle indicates the board is off line or has lost serial communication with the Controller board A long ON time 80 duty cycle indicates the board is online and communicating with the Controller board FLASH Flash when there is activity on its Serial Port In addition to the status LEDs there are 6 additional relay status LEDs on board When any relay is energized or ON its corresponding status LED will become ON also The LED will remain ON for as long as the relay is energized The assignment for each relay status LED is shown in the following table RELAY A Zoe Normal Operation The Two Reader Board accepts 12 VDC with an operating range of 10 to 16 VDC and consumes 400mA of current Locate power source as close to this board as possible Connect power with minimum of 18AWG wire The inp
4. Common Relay 3 NO Door Lock Relay 3 NC Relay 4 NO Separate _ Relay 4 C Power VDC Relay 4 NC OOOO ZONNOUAWNa Supply I eet SCH RED n 5 or 12V DC Out Voltage Is Selected By Jumper J3 On Board 1 YELLOW WHITE Beeper Data 1 Proximity Reader Z Japeay OOOO 485 Com Chassis GND A CardRack Inside Panel 485 Com Z PWR amp Com 485 Gnd Harness a For Rack PWR y Mount Only Gre 2 d Rack mount configuration Two Reader Board ZN 12V 5V J2 Reader VDC Select D74 J3 Reader2 VDC Select D79 XX D80 XY Ea J1 RS485 Termination Jumper O Lille OOOH D000 00 Configuration Dip Switches NUR WN Note For N 485 Communication Connections twist the blue pair together and use as the common use the orange pair as your data pair observing polarity Connect the external drain shield to the appropriate earth ground on one end PRO 2200 Two Reader Module PRO22R2 Installation Guide Wiring Diagram for Connectors 6 through 10 1 OQ 2 3 Ql 4 1 2 QI 3 4 5 Cp Q 7 8 QI 9 10 Ol 1 Q 218 Q312 Ol4 3 O15 Connect to Q 6 chassis GND at O 1 one side ONLY 2 3 CO 4 Ol 5 Z 6 7 La 8 From Diff 9 Panel Remote 10 CO 0218 d 3 2 GER Ol5 w
5. OR STATU TORY INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NO REPRESENTATION OR WARRANTY OF THE DISTRIBUTOR SHALL EXTEND THE LIABILITY OR RESPONSIBILITY OF THE MANUFACTURER BEYOND THE TERMS OF THIS PROVISION INNO EVENT SHALL ENGINEERED SYSTEMS BE LIABLE FOR ANY RE PROCUREMENT COSTS LOSS OF PROFITS LOSS OF USE INCIDENTAL CONSEQUENTIAL OR SPECIAL DAM AGES TO ANY PERSON RESULTING FROM THE USE OF ENGINEERED SYSTEMS PRODUCTS 8 Installation Guide PRO 2200 Two Reader Module PRO22R2 Confidentiality All software drawings diagrams specifications catalogs literature manuals and other materials furnished by Engineered Systems relating to the design use and service of the Products shall remain confidential and shall constitute proprietary rights of Engineered Systems and Customer agrees to treat such information as confidential Customer shall acquire no rights in the design of the Products or the related materials except to use such information solely for the purpose of and only during the time it sells the Products Cus tomer shall not copy the design of any of the Products or use or cause to be used any Product design or related materials for its own benefit or for the benefit of any other party The covenants contained in this section shall remain effective throughout the term of this Agreement and thereafter unless specifically waived by Engineered Systems in writing PRO 2200 Two Reader Modul
6. are not used install a short piece of wire at the input to indicated safe condition Input configuration including debounce and hold time is set via host software Control Output Wiring Six form C relay contacts are provided for controlling door strike or other devices Each may be assigned to door related functions or general purpose output They are configurable as standard energize to activate or fail safe de energize to activate via host software The energized or ON time of each relay can be configured using Pulse control for single or repeating pulses via host software The energized or ON time for a single pulse can be extended up to 24 hours For repeating pulses the on off time can be defined in 0 1 second increments and be repeated up to 255 times 14 Installation Guide PRO 2200 Two Reader Module PRO22R2 Relays 1 and 3 are rated for and normally used to control the door locks associated with readers 1 and 2 respectively While Relays 1 and 3 are sized to handle the typical loads generated by electrical locks load switching can cause abnormal contact wear and premature contact failure Switching of inductive loads i e strike also causes EMI electromagnetic interference which may interfere with normal operation of other equip ment To minimize premature contact failure and to increase system reliability contact protection circuit is highly recommended The following two circuits are suggested Locate the protection circu
7. unpacked carefully in order to prevent damage to the contents The following steps are used to unpack equipment in preparation for installation 1 Open the container and remove the unit s and all packing material Retain the container and all packing materials They may be used again for reshipment of the equipment if needed 2 Inspect the contents for shortage If items are missing items contact the order entry department 3 Visually check contents If damage is discovered perform the following If shipping caused damage to the unit a claim must be filed with the commercial carrier If any other defect is apparent call 800 323 4576 for a return authorization PRO 2200 Two Reader Module PRO22R2 Installation Guide 7 Shipping Instructions To ship equipment back to Engineered Systems 1 Contact the customer service department before returning equipment at 800 323 4576 When calling please have available e A description of the problem or reason for returning the equipment e Original purchase order number invoice number and if the unit is under warranty e Anew purchase order number if the unit is not under warranty 2 Obtain the Return Authorization Number RMA from the customer service department at 800 323 4576 3 Show the RMA number on all packages shipped Packages which are not marked with an RMA number will be refused at the factory and returned COD 4 Carefully pack the equipment for shipment Use the or
8. Configuration LED Output gt High Tri Stated Low Single Color LED LED On LED Off LED Off Bi Color LED Green LED On Both LEDs Off Red LED On To fully utilize each reader port a 6 conductor cable 1 8AWG is required Reader port configuration is set via host software Alarm Contact Wiring Inputs 1 to 8 may be configured to use normally open or normally closed contacts and non supervised or supervised with standard 1 tolerance 1K ohm Four of these inputs have default functional definitions but all eight can be configured to monitor general purpose alarm sensors By default Input 1 is defined as the Door Status Input corresponding to reader 1 and Input 2 is defined as the REX input corresponding to reader 1 Also by default Input 3 is defined as the Door Status Input corresponding to reader 2 and Input 4 is defined as the REX input corresponding to reader 2 Inputs 5 6 7 and 8 are general purpose inputs that can be used to monitor alarm sen sors or can be used as control inputs Inputs 7 and 8 are not accessible when the board is rack mounted Inputs TMP and PFL are typically used for monitoring cabinet tamper and power failure respectively These 2 inputs are not supervised and are not accessible when the board is rack mounted These inputs were primarily provided for the case when this board is mounted remotely and can not take advantage of the tamper and power fail detect inputs on the controller board If these inputs
9. PRO 2200 Two Reader Module Installation Manual Part Number PRO22R2 eK on or oe ee Honeywell TD1143 rev 0501 PRO 2200 Two Reader Module PRO22R2 Installation Guide 3 Contents Warnings dnd LIRE ricrea 4 RI 6 Product Liability Mutual Indemnification niro ani 6 Unpacking roditori 6 Shipping SIRE nale 7 lierna ana 7 WE 8 Deet iere Eege 9 CI RE 9 LED Oe ION reale ai 1 EE 11 Communications EE 11 Reoder E 12 Alarm Contact aereo rali 13 Controel Outpur ieri 13 Mounting Ophions eege 14 Suggested Installation E 14 REENEN 15 Wiring Diagram for Connectors 1 through EE 16 Wiring Diagram for Connectors 6 through VO aa IZ Installation Guide PRO 2200 Two Reader Module PRO22R2 Warnings and Cautions WARNING WARNING A WARNING Before installation TURN OFF the external circuit breaker which supplies power to the system i Before connecting the device to the power supply verify that the output voltage is within specifications of the power supply Do not apply power to the system until after the installation has been completed Personal injury or death could occur and the equipment could be damaged beyond repair if this precaution is not observed Fire Safety and Liability Notice Never connect card readers to any critical entry exit door barrier elevator or gate without providing an alternative exit in accordance with all fire and life safety codes pertinent to the installation These fire and saf
10. a 1 and Data 0 or a Clock and Data signal and provides 5 VDC or 12 VDC reader power a tri stated LED control and buzzer control Two of the six form C relay outputs are sized for the inductive load of door locks and the other four are designed to handle dry circuit signals All of the inputs are capable of four state supervision except the two dedicated inputs Communication to the control panel is accomplished via an RS 485 interface This board requires 12 VDC input power When communication to the control panel is lost this board can grant access based on facility code only General purpose outputs will retain the setting at the time communica tion was lost Up to eight facility codes may be active in each PRO22R2 Keypad input must follow the reader input format and is in place of or multiplexed with the reader data Set Up Jumper Settings Jumper Setting Default Selected Ji OFF SES Port 1 RS 485 EOL terminator is not active C ooN Kessel Port 1 RS 485 EOL terminator is active 2 Reader Power Terminal provides 12 VDC rey 10 Installation Guide PRO 2200 Two Reader Module PRO22R2 Dipswitch Settings S6 S5 S4 S3 S2 S1 SELECTION ADDRESS 1 oFr_ OFF_ OFF_ ON OFF_ ADDRESS 2 OT OFF orr ON Toy ADDRESS 3 ON ON ADDRESS 5 orr Jore ON ON OFF ADDRESS 6 ee ore on on on ADDRESS7 __ or Ton lees Tore ore aooresss or oF pn Reserves or on EE on fo ems on w oes
11. air observing polarity Connect the external drain shield to the appropriate earth ground on one end 5 When daisy chaining RS 485 ports together connect the TR wires from the upstream and downstream boards to the TR terminal and likewise connect the TR wires from the upstream and downstream boards to the TR terminal By factory default J1 is set open If this board is the last board on the RS 485 bus install jumper J1 across both pins closed Closing J1 provides the bus termination required Reader Wiring Each reader port supports a reader with TTL interface Power to the reader is selectable as 5 VDC or 12 VDC pass through This selection is done via setting of jumpers J2 for reader 1 and J3 for reader 2 Set jumper at position 5 for 5 VDC or 12 for pass through 12 VDC The factory defaults set J2 and J3 to 5 For wiring to a reader port Terminal Typ Wire Color Wiegand Reader Clock Data Reader 1 Red Power 5 0r 12 Vdc Power 5 or 12 Vdc LED control LED control 6 Black Gormmon Common The LED control terminal in each reader port can be configured via host software to support one wire single or bi colored reader LED An example of the most common configuration is shown below If Beeper control is not used its terminal can be pro grammed to be the 2 wire for the two wire bi colored reader LED PRO 2200 Two Reader Module PRO22R2 Installation Guide 13 Single Wire Reader LED Control
12. e product itself Any use of this product is subject to the terms and acceptance of the Engineered Sys tems Software Agreement Please request a copy from Engineered Systems and review the agreement carefully Installation Guide PRO 2200 Two Reader Module PRO22R2 Disclaimer Product Liability Mutual Indemnification In the event that a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to property of others Customer shall immediately notify Engineered Systems in writing of all such claims Engineered Systems shall defend or settle such claims and shall indemnify and hold Customer harmless for any costs or damages including reasonable attorneys fees which Customer may be required to pay as a result of the defective Product or the negligence of Engineered Systems its agents or its employees Customer shall hold harmless and indemnify Engineered Systems from and against all claims demands losses and liability arising out of damage to property or injury to persons occasioned by or in connection with the acts or omissions of Customer and its agents and employees and from and against all claims demands losses and liability for costs of fees including reasonable attorneys fees in connection therewith Unpacking Procedure CAUTION If any damage to the shipment is noticed before unpacking a claim must be filed with the commercial carrier All containers should be opened and
13. e PRO22R2 Installation Guide 9 Description The Two Reader Board provides support for up to two access control doors by providing connections for Wiegand or Clock Data type readers supervised inputs and relay outputs This board can be rack mounted in which case only one edge is accessible for wiring Mounting the board flat increases the amount of available I O slightly but also significantly decreases the number of boards that can be mounted in one enclosure The I O terminals are organized to support two doors Starting at the bottom of the rack mount side of the board the first connector provides power to the board The next connec tor provides communication with the Intelligent Controller PRO22IC The next set of terminals is used to connect reader 2 The next set of terminals is used to connect the I O typically associated with reader 2 namely the Door Status and REX status inputs and the Door Lock and Lock Status relay outputs Continuing up this edge the next two connec tors provide the reader and associated I O terminals for reader 1 The last connector on the rack mount edge provides terminals for two additional general purpose alarm inputs When the board is mounted flat two additional relay outputs and two additional general purpose alarm inputs are available along with two dedicated alarm inputs for cabinet tamper and power fault detection on the opposite edge of the board The reader interface accepts a Wiegand signal of Dat
14. ety codes vary from city to city and you must get approval from local fire officials whenever using an electronic product to control a door or other barrier Use of egress buttons for example may be illegal in some cities In most applications single action exit without prior knowledge of what to do is a life safety requirement Always make certain that any required approvals are obtained in writing DO NOT ACCEPT VERBAL APPROVALS AS THEY ARE NOT VALID Engineered Systems never recommends using the PRO 2200 or related products as a primary warning or monitoring system Primary warning or monitoring systems should always meet local fire and safety code requirements The installer must also test the system on a regular basis by instructing the end user in appropriate daily testing proce dures Failure to test a system regularly could make installer liable for damages to the end user if a problem occurs EARTH ground all enclosures for proper installation Use suppressors on all door strikes Use S 4 suppressors for installation Engineered Systems recommends only DC strikes The information in this document is subject to change without notice PRO 2200 Two Reader Module PRO22R2 Installation Guide 5 CAUTION CAUTION NOTICE NOTICE NOTICE IF ANY DAMAGE TO THE SHIPMENT IS NOTICED A CLAIM MUST BE FILED WITH THE COMMERCIAL CARRIER RESPONSIBLE Electro static discharge can damage CMOS integrated circuits and modules To pre
15. iginal packing material whenever possible Limited Warranty All Products sold or licensed by Engineered Systems include a warranty registration card which must be completed and returned to Engineered Systems by or on behalf of the end user in order for Engineered Systems to provide warranty service repair credit or exchange All warranty work shall be handled through Customer which shall notify Engineered Systems and apply for a Return Merchandise Authorization RMA number prior to returning any Product for service repair credit or exchange Engineered Systems warrants that its Products shall be free from defects in materials and workmanship for a period of two years from date of shipment of the Product to Customer The warranty on Terminals Printers Communications Products and Upgrade kits is 90 days from date of shipment Satisfaction of this warranty shall be limited to repair or replacement of Products which are defective or defective under normal use Engineered Systems warranty shall not extend to any Product which upon examination is determined to be defective as a result of misuse improper storage incorrect installation operation or maintenance alteration modification accident or unusual deterioration of the Product due to physical environments in excess of the limits set forth in Product manuals THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THIS PROVISION THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED
16. it as close to the load as possible within 12 inches 30cm as the effectiveness of the circuit will decrease as the distance from the load increases See diagram to follow al Power Source Power Source Relays 2 and 4 are dry circuit level signal relays typically used to indicate the status of the door lock Relays 5 and 6 are general purpose relay outputs and are not available when the board is rack mounted Use sufficiently large gauge of wires for the load current to avoid voltage loss Mounting Options This board can be mounted on edge in the rack mount enclosure provided by Northern Computers or it can be mounted flat against any surface using standoffs under the mounting holes provided in each of the four corners of this board When this board is rack mounted the connectors for two general purpose inputs two general purpose outputs and two dedicated inputs are not accessible and should not be used The most common reason for mounting a board flat is that it is being installed remotely to be located near the door s being monitored In this case it will be mounted in its own enclosure creating the need to monitor cabinet tamper and power fault detection inputs The two additional general purpose inputs and outputs provided allow for the monitoring of extra alarm sensors and control of local horns or other equipment Suggested Installation Sequence 1 Set Jumpers and DIP switches 2 Mount this board in the appro
17. priate enclosure If this board is being mounted in a rack the component side of the board is to the right when facing the rack 3 Connect the communications and power supply to the circuit boards with the Power Supply Harness WARNING DO NOT CONNECT THE POWER SUPPLY TOTHE AC SOCKET UNTIL ALL WIRING HAS BEEN INSTALLED AND RECHECKED 4 Connect wiring to the reader interfaces as appropriate PRO 2200 Two Reader Module PRO22R2 Installation Guide 15 5 Connect wiring to alarm input sensors or install jumper wire as appropriate 6 Connect relay output wiring as appropriate 7 Connect communications wiring to the Intelligent Controller 8 Recheck wiring for correct connections and continuity 9 When all boards have been installed connect the Power Supply Cord for proper connections and power 10 Setup the panel controls using the host software Specification The Two Reader is for use in low voltage class 2 circuits only Primary power 12VDC 10 400mA Relay contacts Relays 1 amp 3 outputs Form C 5A 28 VDC resistive Relays 2 amp 4 amp 5 amp 6 outputs Form C 2A 28 VDC resistive Inputs 8 supervised End of Line resistors 1k ohm 1 tolerance 2 unsupervised dedicated inputs Reader interface Reader power 5 VDC 5 6 2 or 12 VDC pass through 150mA max each Reader LED output TTL compatible high gt 3V low lt 0 5V 5mA source sink max Reader buzzer output Open collector 5 VDC open circuit max
18. ut voltage is regulated to 5 VDC The regulated voltage or the 12 VDC pass through is available for powering the readers The selection is made via jumpers and is available at both reader connectors NOTE POLARITY for 12 VDC power is important Make sure the 12 VDC is connected to the terminal labeled 12V and the return is connected to the terminal labeled GND Communications The Two Reader Board communicates to host controller via an RS 485 interface The interface allows for multi drop communication of up to 4 000 feet 1 200 m total per port Use two twisted pair minimum 24AWG with shield for communication The default speed of this port is 38 4Kbps but it can be downgraded to 19 2Kbps or 9 6Kbps if the line conditions or receiving equipment require it see jumper and DIP switch settings 12 Installation Guide PRO 2200 Two Reader Module PRO22R2 For Wiring to an RS 485 port 1 TR is the plus side of the transmit and receive differential signal 2 TR is the negative side of the transmit and receive differential signal 3 GND is the signal ground The wiring for this signal is required and NOT optional This signal must NOT be connected to chassis GND 4 Use 24 AWG low capacitance two twisted pair shielded cable Belden 9842 or equivalent Orange white stripe White orange stripe Common Note For N 485 Communication Connections twist the blue pair together and use as the common use the orange pair as your data p
19. vent damage always follow these procedures Use static shield packaging and containers to transport all electronic components including completed reader assemblies Handle all ESD sensitive components at an approved static controlled workstation These workstations consist of a desk mat floor mat and an ESD wrist strap Workstations are available from various vendors This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This document and the data in it shall not be duplicated used or disclosed to others for procurement or manufacture except as authorized by and with the written permission of Engineered Systems The information contained in this document or in the product itself is considered the exclusive property and trade secrets of Engineered Systems Copyright laws of the United States protect all information in this document or in the softwar