Home

Honeywell Door 6160V User's Manual

image

Contents

1. Fixed Word LCD backlit 6160V 2 x 16 Alpha Numeric Super twist LCD backlit Sounder Speaker Electrical Voltage 12VDC power limited Current 6150V 160mA ARMED LED lit LCD backlight and sounder on reduces to 6 0mA when panel is operating in standby mode backlight off 6160V 190mA ARMED LED lit LCD backlight and sounder on reduces to 6 0mA when panel is operating in standby mode backlight off NFPA72 Compliant TABLE 1 ZONE DESCRIPTORS AND INDEX ENTRIES ALARM 002 DOOR 057 KITCHEN 105 PATIO 146 UPSTAIRS 207 ATTIC 009 EMERGENCY 067 LAUNDRY 106 POLICE 151 UTILITY 208 BABY 012 EXIT 071 LIBRARY 109 POOL 152 WINDOW 217 BACK 013 FIRE 079 LIVING 113 ROOM 162 YARD 223 BASEMENT 016 FLOOR 080 MAIN 122 SHED 168 ZONE 225 BATHROOM 017 FRONT 085 MASTER 123 SHOP 170 1ST 228 BEDROOM 019 GARAGE 089 MEDICAL 125 SIDE 173 2ND 230 CLOSED 040 GUN 094 MOTION 131 SLIDING 175 3RD 232 DEN 050 HALL 095 OFFICE 136 SMOKE 176 DETECTOR 052 HOUSE 099 OPEN 138 STORAGE 185 DINING 053 INSIDE 101 PANIC 144 SUPERVISED 190 REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM For the latest warranty information please go to http www security honeywell com hsc resources wa index html Honeywell 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright
2. 2009 Honeywell International Inc www security honeywell com K0022V3 3 09 Rev A
3. Honeywell K0022V3 3 09 Rev A ADEMCO 6150V amp 6160V Voice Remote Keypads INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The ADEMCO 6150V and ADEMCO 6160V are addressable remote keypads designed for use with ADEMCO control panels and provide the following features e Backlit Display e Programmable Function Keys e Voice Status e Built in Sounder e Message Center e Supervised by control panel if supported Notes e When used with the ADEMCO VISTA 15P VISTA 20P control panels address 16 must be assigned to the first keypad Additional keypads must be assigned to address 17 23 Refer to Setting The Keypad Options e Keypad keys are continuously backlit for convenience e Permanent display backlighting is an option on some controls refer to control panel s instructions for details e Voice Chime should only be enabled when used with control panels that support the chime by zone mode e g VISTA 15P VISTA 20P This mode must be enabled at the control panel Refer to the control panel s installation and setup guide for information on how to program the chime mode e Voice Chime e Use only zone descriptors supported by this keypad If using zone descriptors not supported by this keypad you must turn voice status and voice chime off Table 1 is a list of applicable zone descriptors and index entries Refer to the control panel s installation and setup guide for information about how to program zone descripto
4. er desired keypad address 5 Press to save the displayed address and enter the Voice Chime mode VOICE CHIME alpha keypad or C fixed keypad is displayed along with the selected mode 1 or 0 Setting The Voice Chime Mode 6 Press 1 to set the Voice Chime mode on or press 0 to set the Voice Chime mode off 7 Press to save the displayed Voice Chime mode and enter the Additional Console voice keypad mode ADDITIONAL CON alpha keypad or A fixed keypad is displayed along with the selected mode 1 or o Note Setting Voice Chime mode off does not effect the voice status or alarm annunciation Setting The Additional Console Mode The Additional Console mode must be set for all voice keypads being used 8 Set the voice keypad Additional Console mode as follows a On the Primary voice keypad press 0 to set the Additional Console mode to NO b On any secondary voice keypads press 1 to set Additional Console mode to YES 9 Press to save the mode VIEWING THE KEYPAD ADDRESS Press and hold down the 1 key and 3 key at the same time for about 3 seconds The current address is displayed No key entry is allowed Press any key to exit or wait 10 seconds to exit the viewing mode OPERATING THE KEYPAD For operating instructions see the User Guide for the control panel used with this keypad SPECIFICATIONS Physical 6150V 4 7 8 H x 6 1 4 W x 1 D 6160V 5 5 16 H x 7 3 8 W x 1 3 16 D Displays 6150V
5. ottom edge and pulling the case apart WIRING AND INSTALLATION Keypads can be surface mounted using drywall anchors or to a single or double gang electrical box 1 Remove the case back by pushing up the two snaps along the keypa s bottom edge and pulling the case apart See diagram above 2 Route wiring from the control panel through the opening in the case back Mount the case back to a wall or electrical box 4 Wire directly from the keypad s terminal block to the terminal block on the control board See Wiring Table that follows Use only 16 24 AWG wire RECORD VOLUME PLAY 4x E Gr SIDE VIEW READY lt gt Zis 8 cove 9 cume MESSAGE lt gt 6160V 001 V1 9 LED Function ARMED Lights red when the system is armed in any mode READY Lights green when the system is ready to be armed MESSAGE Flashes red when message waiting or lights red steady when in record mode PROGRAMMABLE FUNCTION KEYS The keypad s programmable function keys A B C are normally used for keypad panic functions but they can be programmed for other special functions instead If they are programmed for other special functions the associated keypad key pairs still provide the respective panic alarm if programmed Refer to the control panel s Installation amp Setup Guide for details Wiring Table All Keypads Key
6. pad Control Panel Wire Color G Data In Green Aux Pwr GND Black Aux Pwr Red Y Data Out Yellow 5 Re attach the keypad to the case back 6 Remove clear protective film from LEDs 6160V only SETTING THE KEYPAD OPTIONS The procedures that follow are used to set the keypad address voice chime mode and additional voice keypad mode Setting The Keypad Address When used with the VISTA 15P VISTA 20P control panels address 16 must be assigned to the first Keypad Additional Keypads must be set at 17 23 and must be enabled additionally in control programming fields 190 196 The keypad can either be set for an address of 00 30 or for non addressable mode 31 The default keypad address is 31 For valid address settings for your keypad refer to the control panel s Installation amp Setup Guide Note e If unable to enter the address mode power down power up and try again e If 10 seconds pass with no key entry the keypad automatically exits the address mode You must power down power up and start the address mode again e The keypad will not enter the address mode if the control panel is in programming mode 1 Apply power to the keypad 2 Within 60 seconds of applying power to the keypad press and hold down the 1 key and 3 key at the same time for 3 seconds The current keypad address will be displayed 3 Press 00 The current address is cleared 4 Ent
7. rs e For the 6160V ONLY supervision must be enabled for commercial fire installations UL NOTE ADEMCO 6150V cannot be used for commercial fire applications KEYPAD DISPLAYS AND LEDS The keypads have the following display features Function Equivalent Key Pairs Keys A 1 and B and C 3 and D NONE e Function keys must be held down for at least 2 seconds to activate the programmed function e If functions other than panics are assigned to the programmable function keys programmed panics must be initiated by pressing the programmed key pair Model Fixed 2 Line 2 Digit Custom Word Alpha Zone Zone Display Display Identifier _ Descriptors 6150V X X 6160V X X The following table identifies the keypa s LEDs and associated functions FUNCTION KEY LABELS A set of adhesive backed labels with some typical function symbols i e fire police personal emergency etc is provided These labels can be placed on or next to the keys to identify each key s function for the end user as determined by the capability and programming of the control panel refer to the installation and setup guide for the control panel B ee o 2am 3 star iP xr 0 c ca z STATUS VOICE FUNCTION lt 7 F D GEMGE l T MOUNTING RELEASE SNAPS Remove case back by pushing up the 2 snaps along the keypad s b