Honeywell Dehumidifier H1008 User's Manual

image

Contents

1. i fo g gt Time Figure 11 Variation in Duct Temperature and Relative Humidity Warm Furnace Room March 11 1998 Minneapolis Minnesota Note the large variations in temperature and relative humidity in the duct while the dewpoint remains constant Each fan cycle causes the temperature in the duct to change about 8 F which drives a 12 change in relative humidity However the dewpoint which is the actual amount of moisture in the air doesn t change Which do you think would be better to use as a control input The phenomena discussed above does not present the same problems for the H1008 Automatic Humidity Control Because the H1008 has an on board temperature sensor it actually measures both temperature and relative humidity and calculates the dewpoint and uses that value in all of its humidity control algorithms effectively eliminating the effects of variations in duct temperature and relative humidity Page 16 of 22 Rev 2 0 1998 Honeywell Inc Digitial Output 2 Humidity Control Located Too Close to Bypass Duct 63 7048 A second problem that can occur in many installations is a result of the humidity control being located too close to the bypass duct We always recommend mounting the humidity control as far upstream from the bypass duct as possible gt 24 is desired However in many installations the desired separation is not possible and compromises have to be made The result is tha
2. 15 20 25 30 35 40 45 50 Outside Temp deg F Figure 4 Research Products AutoTrac Outdoor Temperature Compensation AutoTrac is a trademark of Research Products Corporation Page 6 of 22 Rev 2 0 63 7048 1998 Honeywell Inc The AutoTrac control does not have the ability to provide true dewpoint control This may result in overhumidification at times when the temperature is greater than normal conditions and underhumidification if the temperature is less than normal conditions For example if during night setback the temperature was 60 F if the AutoTrac were able to achieve its 45 RH the dewpoint would be 39 F If the temperature were raised to 72 F during recovery the relative humidity would only be 30 All opportunities to humidify during setback would be lost Some additional items noted during our testing of this product conducted in the fall of 1997 e If the outdoor sensor fails open or is not connected the humidistat will not function with no feedback to the user e Ifthe sensed outdoor temperature exceeds 50 F the humidistat will not function losing opportunities to humidify under those conditions The concept of adjusting the indoor humidity level depending on what is happening outdoors in one that we embrace in fact Honeywell pioneered the concept with the Perfect Climate Comfort Center What we heard that installing contractors do not embrace is the time and effort require
3. dewpoint vs the percent on time of the furnace you don t end up with just one line on the graph You end up with literally thousands of lines depending on all the combinations of window type indoor temperature ASHRAE design temperature balance point and furnace oversizing But through computer simulation we were able to determine the range of values that we could reasonably expect to encounter Once this was known we could design a control that could span this entire range Because the effect of all of the above variables add or subtract in the same way by Page 9 of 22 Rev 2 0 63 7048 1998 Honeywell Inc adjusting a single input value we can achieve a control point that satisfied every one of the thousands of combinations of the variables Voila By adjusting a single knob setting we can provide a solution for the entire range of five input variables Figure 7 shows the operational characteristics of the H1008 Automatic Humidity Control with HumidiCalc Software e Knob Setting 1 40 0 SS 3 ol a Knob Setting 2 S 30 0 Knob Setting 3 A 20 0 lt Knob Setting 4 2 x Knob Setting 5 y 10 0 j i e Knob Setting 6 lt q Knob Setting 7 Eo 40 0 10 20 308 0 80 90 100 Knob Setting 8 E Knob Setting 9 20 0 e Knob Setting 10 30 0 40 0 Percent On Figure 7 Operation Character
4. relative humidity With conditions of constant moisture content in the air dewpoint of 50 F the relative humidity varies between 35 and 70 as the temperature varies between 60 F and 80 F 80 0 Relative Humidity RH A O O 55 60 65 70 75 80 85 Dry Bulb Temperature deg F Figure 1 Variation of Relative Humidity with Changes in Temperature at a Constant Moisture Level Page 2 of 22 Rev 2 0 63 7048 1998 Honeywell Inc e Defining a Comfortable Humidity Level Much research has been conducted on what combination of temperature and humidity creates the most comfortable indoor environment The 1997 ASHRAE Fundamentals Handbook defines how comfort is perceived as a function of temperature and humidity Figure 2 shows a summary of the ASHRAE conclusions 90 RH 80 RH 70 RH 60 RH AA 50 RH Comfort Zone 40 RH Dewpoint F 30 RH 20 RH 10 RH 60 65 70 75 80 Dry Bulb Temperature F Figure 2 ASHRAE Winter Comfort Zone In designing a humidifier control what is of particular interest is the lower region of the comfort zone Figure 2 shows that a comfortable humidity level is defined in terms of dewpoint rather than relative humidity The lower end of the winter comfort zone is a dewpoint of 36 F for dry bulb temperatures ranging from about 69 F to 76 F This strongly supports the notion that a comfortable humidity level is best described by d
5. we limit the amount that the percent on value can change after each cycle for the number of cycles that are typically required to reach steady state conditions e Performance Curves Extensive testing of this algorithm has been done over the past year including e Software simulation run entirely on a computer using the house models developed for the Perfect Climate Comfort Center with the H1008 software algorithm e Closed loop testing with the H1008 hardware and software actually controlling the inputs to the simulation models This approach was also used in the development of the Perfect Climate Comfort Center e Field testing with devices and data logging equipment installed in sites in Minnesota West Virginia and New Hampshire in the United States and Alberta northern Manitoba and Northwest Territories in Canada for portions of the 97 98 heating season Some very interesting observations were made during this test program Shown below are samples of how the H1008 Automatic Humidity Control performed under a wide range of conditions Page 11 of 22 Rev 2 0 63 7048 1998 Honeywell Inc 80 70 60 50 40 30 20 Temperature F 10 Humidifier Cycles MO M e UU 40 Room Temp o 735 4 30 Temp Setpoint Window Temp 25 4 3 Qa 5 720 O ass Dewpoint D p l45 9 Outdoor Temp 410 Furnace Cycles 15 i ul 0 14 16 18 20 22 24 26 28 32 Time hrs Figu
6. 08 Sensors This method of mounting greatly improves the sealing of the return air duct Building inspectors sometimes require leaks around the rectangular cutouts to be sealed by caulking 3 Simple Wiring Large screw terminals are used with guides to hold the wires while tightening the screws no micro miniature terminal blocks here Terminals are well labeled and intuitive see Figure 15 Figure 15 H1008 Wiring Terminals Page 20 of 22 Rev 2 0 63 7048 1998 Honeywell Inc Logic to determine if the fan is running is determined from the equipment inputs so a current sensing relay is never required providing additional savings to the contractor on jobs that would normally require one 4 Automatic Configuration and Diagnostics Unlike AutoTrac the H1008 does not require a jumper selection if the control is installed with either a bypass or powered flow through humidifier The H1008 also automatically detects whether or not the outdoor sensor is installed One final feature to help the installing contractor a device status light see Figure 16 The flashing frequency of the light tells the contractor if the device has power if the humidification relay is energized if the device is in Test mode or if the device has detected a sensor failure or some other hardware fault All of these features have been added for the same reason to save the contractor time Figure 16 Device Status Light e The Honeyw
7. 3 illustrates why condensation occurs Window Panes Inside 70 F Window 40 Outside 0 F Figure 3 Temperature Profile of Double Pane Window Figure 3 shows the temperature profile through a typical double pane window If it is 70 F inside and 0 F outside depending on the insulating value of the window the temperature at the window surface may be around 40 F Therefore in this example under these conditions the maximum dewpoint that this house could withstand without condensation forming on the window would be 40 F If the outside temperature were to increase the window temperature would also increase meaning that the house could stand more humidity Conversely if the outside temperature were to decrease the window temperature would decrease meaning the humidity level in the house would have to decrease further to prevent condensation A second factor in determining window temperature that is not always considered is indoor temperature Raising and lowering indoor temperature will similarly raise and lower the window temperature This can be a significant factor in applications where programmable setback thermostats are used If a thermostat sets back at night the allowable humidity level in the home will be less than during periods when the temperature is at its normal setting This sets the stage for the quest to achieve both a comfortable humidity level and dry windows Page 5 of 22 Rev 2 0 63 7048 1998 Ho
8. Honeywell Honeywell H1008 Automatic Humidity Control with HumidiCalc Software Rev 1 0 Copyright 1998 Honeywell Inc All Rights Reserved May 27 1998 e Automatic Humidity Control The Honeywell H1008 Automatic Humidity Control with HumidiCalc Software is the world s most advanced stand alone humidity control Simple to install easy to troubleshoot it is designed to save the installing contractor time while maximizing benefits to the homeowner It s much more than a humidistat it s a sophisticated electronic control with the ability to maintain a comfortable humidity level in a home while preventing condensation on windows over a wide range of weather conditions e Back to Basics Expressing Humidity When most people think of humidity they probably are thinking of relative humidity But there is a significant drawback in expressing humidity in terms of relative humidity In order for relative humidity to be meaningful the temperature of the air needs to be also known Simply stating that the humidity is X does not really indicate how much moisture is present in the air The best measure of the humidity level in the air is dewpoint not relative humidity Dewpoint is a measure of the absolute amount of moisture in the air If the temperature of the air is raised or lowered the dewpoint will remain constant unless moisture is added or taken away Figure shows the effect that changing temperature has on
9. ase the temperature in that location can be much cooler than the temperature in the living space If the temperature at the humidity control was 64 F the relative humidity sensed by the humidistat would be 14 higher 60 in the duct vs 46 in the living space for a dewpoint of 50 F than the relative humidity in the living space Once the system fan starts the temperature in the duct begins to move toward the living space temperature but it takes several minutes before the error is eliminated In these cases the errors in sensed humidity will cause the humidifier operation to be affected either supplying too much or not enough humidity Figure 11 shows the first example in practice This data was taken from one of our field test sites during a night setback period with no calls for heat while running in the CIRC mode controlled by a Perfect Climate Comfort Center 10 minutes of system fan running each half hour Page 15 of 22 Rev 2 0 63 7048 1998 Honeywell Inc Room Temp Dewpoint Duct RH Temperature F Relative Humidity Humidifier Cycles Fan Cycles G L Furnace Cycles W oO oO oO oO Oo oO Oo Oo oO oO oO oO jo o oO oO oO jo oO oO oO o oO oO o oO oO oO oO oO oO oO oO oO oO o O m oO oO oO m o O m o m D D e e 7 7 N M o o o oO oO
10. d wiring an outdoor sensor up to an hour on some jobs So armed with an unequalled knowledge of comfort systems we set out to design a humidity control with exceptional performance that would also make life easier for the installing contractor e H1008 Automatic Humidity Control with HumidiCalc The Basic Idea The idea for the H1008 Automatic Humidity Control was born by considering some very obvious facts e Wiring between the humidity control and an outdoor sensor can be very difficult e Humidifiers and duct mounted humidity controls are usually installed near the HVAC equipment e Wiring between the humidity control and the HVAC equipment would usually be pretty easy e If you could replace the wiring from the humidity control to the outdoor sensor with wiring to the HVAC equipment it would save a lot of time Here s a few more e By monitoring the W terminal on your furnace you could tell how much it was running e The colder it gets outside the more your furnace runs You re probably starting to see where this is headed Here s the basic idea if we could estimate the outdoor temperature by monitoring the calls for heat we could conceivably replace the outdoor sensor with some simple wiring between the HVAC equipment and the humidity control Page 7 of 22 Rev 2 0 63 7048 1998 Honeywell Inc e H1008 Automatic Humidity Control with HumidiCalc The Technical Approach We found that there is more than a cas
11. e Quest for Dry Windows All Winter Long As we Said above If the dewpoint could always be maintained at 50 F there would be no complaints about humidity However as much as we would like to live year round in an environment with a 50 F dewpoint unfortunately that can t always be done Here s why The need to humidify for a comfortable indoor environment is driven by the fact that all homes breathe exchanging outside air for inside air When the amount of moisture contained in the outside air is less than that in the inside air the humidity level will go down If the outside air is very dry at some point moisture will need to be added to maintain a comfortable humidity level The drier the outside air the more humidification that will be needed When temperatures get very cold outside the air can hold a very limited amount of moisture Thus the very driest air occurs when the temperatures get very cold When comfortable indoor humidity levels are maintained during extremely cold weather problems with condensation can occur Usually this condensation will occur first on windows because windows generally have less insulation value than walls If the temperature of the inside surface of the window is lower than the dewpoint of the inside air condensation will occur Over time this condensation can be very damaging to the finish and the structure of the window Page 4 of 22 Rev 2 0 63 7048 1998 Honeywell Inc Figure
12. ell H1008 Automatic Humidity Control Sell It or Choose to Sell Against It Well there you have it A complete description of the Honeywell H1008 Automatic Humidity Control with HumidiCalc Software the world s most advanced stand alone humidity control Summarized below is a direct comparison of the H1008 to the AutoTrac highlighting its many advantages both in installation and performance It is essential that these advantages be communicated to the contractor so they can make an informed decision because they do have a choice They can choose to install Honeywell humidifiers and the Honeywell H1008 Automatic Humidity Control with HumidiCalc Software Or they can stick with AutoTrac and sell against the contractors who have switched Page 21 of 22 Rev 2 0 63 7048 1998 Honeywell Inc e Direct Comparison Chart Honeywell H1008 Automatic Humidity Control with HumidiCalc Software vs AutoTrac Honeywell H1008 AutoTrac Installation Outdoor Sensor Not required for single stage furnaces Recommended for heat pumps and multi stage furnaces Required for all installations at an incremental cost of 20 to 50 for new construction and 30 to 60 minutes installation time for retrofit Significant noise problems reported due to sensor wiring Mounting 34 diameter hole for inserting sensors into return air duct 3 x 5 rectangular cutout in return air duct required for mounting Buildin
13. ewpoint not relative humidity In fact within the temperature range of 69 F to 76 F the relative humidity can vary from 23 to 81 and still be considered to be in the comfort zone as ASHRAE has defined it You can begin to see the problem in trying to use relative humidity to control humidity level Relative humidity is not a direct measurement of the amount of moisture in the air As shown in Figure 1 it is very dependent on the temperature of the air being measured Conditions for Thermal Comfort 1997 ASHRAE Fundamentals Handbook page 8 12 Page 3 of 22 Rev 2 0 63 7048 1998 Honeywell Inc The message to take away from all this is If you are in the business of trying to provide a comfortable indoor environment controlling a humidifier by sensing relative humidity may not result in optimum control Especially poor performance may result when the temperature in the living space experiences large swings like in instances where setback thermostats are used In these applications a humidity control that controls based on dewpoint will result in optimum control over all conditions Honeywell H1008 Automatic Humidity Control with HumidiCalc Software does just that While most humidity controls simply have a humidity sensor the H1008 Automatic Humidity Control has both humidity and a temperature sensor This allows dewpoint to be calculated and the humidification equipment controlled to achieve the desired dewpoint e Th
14. g inspectors sometimes require leaks around the rectangular cutouts to be sealed by caulking or foam Wiring Large screw terminals provided for wiring Determining Miniature terminal blocks used for wiring Model 50 fan operation automatically detected by control logic 24 VAC input provided directly from HE360 Powered Humidifier no separate transformer required current sensing relay required in applications without humidifier contacts on furnace control board Separate transformer required for all installations to power control System Configuration and Diagnostics No jumper selection required if the control is installed with either a bypass or powered flow through humidifier Automatically detects whether or not the outdoor sensor is installed Device status light provides key diagnostics Jumper selection required to switch between flow through and powered humidifier to avoid damage to equipment No diagnostics provided Performance Sensors Absolute humidity control based on dewpoint performed with duct mounted humidity and temperature sensors Humidity sensor only Indoor Temperature Compensation Dewpoint control allows for accurate control during aggressive setback periods Sensing of relative humidity only Lower window temperatures caused by lower indoor temperatures not accounted for which could cause overhumidification Return Air Duct Temperature Variations Dewpoint control allows f
15. istics of the H1008 Automatic Humidity Control with HumidiCalc The H1008 Automatic Humidity Control with HumidiCalc attempts to control the humidity level to a dewpoint of 50 F The control continuously monitors the calls for heat and maintains a running estimate of the current percent on of the equipment Based on the knob setting the H1008 calculates the maximum allowable dewpoint for the current percent on If this value is less than 50 F that becomes the new control point e How Does it Work Under Real World Conditions Very Well Thank You The discussion thus far has been limited to the analysis around steady state conditions that is conditions where the heating load is not changing We know of course that in the real world conditions are not always steady state If either the outdoor temperature or the setpoint changes the heating load changes Of particular interest to us is what happens when the setpoint changes either manually or automatically through the use of programmable thermostats This causes a step change to the heating load a much faster change in load than will occur due to even the most rapid changes in outdoor temperature Page 10 of 22 Rev 2 0 63 7048 1998 Honeywell Inc Nobody has more knowledge about heating loads than Honeywell the world leader in temperature control More furnaces are controlled by Honeywell thermostats than any other so nobody understands the science of temperature control bette
16. ize In this case the furnace will only be running 50 of the time at the ASHRAE design temperature of 16 F Next we looked at the insulation values of windows and found that naturally there is a relationship between the temperature of the inside surface of the window and the outdoor and indoor temperatures This was shown in Figure 2 Of course all windows are different but Figure 6 shows some nominal values for typical window types ma 5 1 78 e 60 7 eb a 50 e Single Glaze a Double Glaze z Triple Glaze E zo 5 10 50 0 50 100 Outdoor Temperature deg F Figure 6 Typical Window Surface Temperatures with Tindoor 72 F Again what s important about the window surface temperature is that is the upper limit of the dewpoint that we can allow in the living space If the dewpoint of the air in the living space exceeds the window surface temperature condensation will occur If the dewpoint stays below the window surface temperature we have dry windows If you look at Figure 5 and Figure 6 you see that outdoor temperature is present in both equations We took these equations and with a little algebra were able to develop an equation for the window surface temperature or equivalently the maximum allowable dewpoint in terms of the percent on time of the furnace Now for the tricky part if you graph maximum allowable
17. neywell Inc e Outdoor Temperature Compensating Humidity Controls Honeywell with the Perfect Climate Comfort Center was the first to introduce an electronic humidity control system for the residential market designed to automatically adjust humidity levels based on outdoor temperature This system also considers the effect of indoor temperature in its algorithm providing optimum control for all combinations of indoor and outdoor temperature The Honeywell H1008 Automatic Humidity Control when installed with the C7089H Outdoor Temperature Sensor functions as a true dewpoint control just like the Perfect Climate Comfort Center In 1997 Research Products introduced its AutoTrac control The AutoTrac is a stand alone electronic humidistat that when installed with an outdoor sensor will adjust the relative humidity setpoint per a programmed reset schedule We have tested the AutoTrac and found that it does perform as advertised It attempts to control to 45 RH until the outdoor sensor value reaches the point at which a 2 RH reduction in setpoint is made per F change in outdoor sensor value Figure 4 graphically shows the linear reset curves 50 0 5 e Knob Setting 1 m Knob Setting 2 a Knob Setting 3 lt Knob Setting 4 Knob Setting 5 e Knob Setting 6 Relative Humidity t Knob Setting 7 30 25 20 15 10 5 0 5 10
18. on relative humidity like the AutoTrac These findings are summarized below Page 14 of 22 Rev 2 0 63 7048 1998 Honeywell Inc e Making the Best of a Duct Mounted Humidity Control One of the things we learned early on in this development was that a return air duct is not the best place to mount a humidistat that controls only by relative humidity There are two major factors that can dramatically affect the accuracy of standard humidistats 1 Ambient Temperature of the Equipment Room If the temperature in the area where the HVAC equipment is installed differs much from the living space temperature errors in sensed RH can develop Remember earlier in this paper in Figure 1 we talked about how relative humidity is very dependent on ambient temperature We have seen installations where the ambient temperature at the humidity control is very different from the living space One example of this is when the equipment is installed in a relatively confined furnace room During periods when the furnace is running a lot the temperature in that room can exceed 80 F when the temperature in the living space is only 72 F This 8 F difference in temperature causes the relative humidity sensed by the humidistat to be 11 lower 35 in the duct vs 46 in the living space for a dewpoint of 50 F than the relative humidity in the living space Another example is when the equipment is installed in an unfinished area of the house In this c
19. or accurate control even if return air temperature differs from living space Sensing of relative humidity only will cause large errors in control if return air temperature differs from living space Bypass Air Affecting Control Dewpoint control allows for accurate control even if bypass air affects sensor readings Sensing of relative humidity only will cause large errors in control if bypass air affects sensor readings 63 7048 Page 22 of 22 Rev 2 0 1998 Honeywell Inc Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Home and Building Control Honeywell Limited Honeywell Limit e 155 Gordon Baker Road North York Ontario Honeywell Asia Pacific Inc Room 3213 3225 Sun Hung Kai Centre No 30 Harbour Road Minneapolis MN 55408 0524 M2H 3N7 Wanchai Hong Kong Honeywell Latin American Region Honeywell Europe S A 480 Sawgrass Corporate Parkway 3 Avenue du Bourget Suite 200 1140 Brussels Sunrise FL 33325 Belgium Honeywell amp Printed in U S A on recycled paper containing at least 10 63 7048 8 98 post consumer paper fibers www honeywell com
20. r than we do In order for the prediction of outdoor temperature based on furnace cycling to work we needed to develop an algorithm to filter out changes in heating load that are not the result of changes in outdoor temperature We have developed a two stage filter which we ve shown to be very effective in preventing the humidity control from being thrown off by heating load changes due to setpoint changes The first filter looks at the furnace cycle times that can be expected under normal steady state conditions We analyzed the limit of furnace cycle times for heating loads varying from 5 to 95 percent and cycle rates varying from 3 to 9 cycles per hour and determined the minimum and maximum length of a heating cycle that can occur in steady state conditions Times measured that are shorter or longer than these limits are ignored known to be the result of some outside influence not normal cycling The second filter is in place to compensate for the cycling pattern that exists as the heating system works through a setpoint change When a thermostat starts a recovery period from a setback temperature the first on cycle will typically exceed the normal maximum and thus will be ignored in our percent on calculation The subsequent on cycles will likely be within the normal limits but longer than the steady state cycling pattern that will ultimately develop In order to prevent the percent on calculation from being severely affected
21. re 8 Software Simulation of H1008 Automatic Humidity Control Algorithm The simulation is performed by constructing a house model with a given volume wall and window heat loss factors infiltration rates and internally generated humidity The house is then subjected to varying weather conditions and temperature setpoint profiles The result is shown above a pattern of furnace and humidifier cycling is established in response to the input conditions As seen in Figure 8 the H1008 algorithm performs quite well During the night setback periods when it is very cold outside the humidifier cycles less frequently than it does during the afternoon hours During the entire period the dewpoint tracks just below the window temperature maintaining moisture free windows 63 7048 Page 12 of 22 Rev 2 0 1998 Honeywell Inc 80 40 Indoor Temp 35 60 30 50 Temp Setpoint Window Temp 25 E aot L S 30 20 oO rom Dewpoint 5 20 2 15 Outdoor Temp 10 gt 4 10 0 s Furnace Cycles pee 5 10 w nrg Mm m m W Q 20 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Time hrs Figure 9 H1008 Automatic Humidity Control Hardware Closed Loop Run Figure 9 is the identical case with the actual H1008 hardware and software in control of the simulated humidifier The results are very similar with relatively light cycling of the humidifier during the colder periods and heavier cycling of the h
22. s 13 Because the H1008 controls based on dewpoint it is able to cycle intermittently during the temperature recovery period when the relative humidity is artificially low This ensures that the dewpoint is maintained dewpoint below the window temperature Figure 13 shows additional field test data taken the following night at the same site In this case the humidifier was wired to operate each fan and heat cycle simulating a humidifier operating when the sensed relative humidity is below the humidity setpoint In many cases this will occur each time the furnace is running The effect of the heating of a standard humidistat like AutoTrac is to lower the sensed relative humidity essentially creating a humidifier lock on condition 100 40 f 90 Duct Temp f 135 80 f Room Temp f 70 30 60 f 25 50 Window Temp 40 30 Dewpoint Temperature F Relative Humidity iy oO Digitial Output f 20 f f Outdoor Temp Duct RH 1 10 10 0 FHumidifier Cycles Fan Cycles G Furnace Cycles W 15 10 l R muy E li as E a 0 20 o o o o o o o o o o o o r m m lt lt t Lo o oO oO N oO Oo Time Figure 13 Variation in Duct Temperature and Relative Humidity Simulated AutoTrac Performance Setting 4 March 12 1998 Minneapolis Minnesota Page 18 of 22 Rev 2 0 63 7048 1998 Honeywell Inc While the humidifier
23. t in many cases the hot air coming from the bypass duct heats up the return air duct and spills upstream toward the humidistat This affects the relative humidity sensed by the control in a manner similar to the first problem discussed above In fact this problem can be even more severe The effect of this heating of the humidistat is to lower the sensed relative humidity 100 40 90 Duct Temp f 735 80 t Room Temp 70 7 30 60 Window Temp 125 50 J aae ee ee 40 20 Dewpoint 30 Duct RH Temperature F Relative Humidity f 20 Outdoor Temp 10 10 of Fan Cycles G Humidifier Cycles ules Te Furnace Cycles W 19 i wa mann J ra 0 20 5 o oO o fo oO oO j o S 2 2 2 2 s 2 Q 2 ro ro So oS 2 c3 Tt x re Ye X Oo z ro o o Oo x O D 2 oO Time Figure 12 Variation in Duct Temperature and Relative Humidity Bypass Air Affecting Sensor March 11 1998 Minneapolis Minnesota Figure 12 shows this in practice This data was also taken from one of our field test sites during a long recovery period from night setback Again note the large variations in temperature and relative humidity in the duct while the Page 17 of 22 Rev 2 0 1998 Honeywell Inc Digitial Output dewpoint increases slightly in response to the humidifier cycles During this period the relative humidity sensed in the duct is as low a
24. tition who are still installing AutoTrac How much of an advantage These are the facts Jn new construction electricians are charging 40 to 70 to wire an AutoTrac installation In retrofit applications the contractor is faced with a large variation in the time required to install the outdoor sensor In cases if a new condensing unit is being installed running the outdoor sensor wires with the control wires to the condenser adds very little time In other cases it may take hours or in some cases a compromise on the location is made affecting the performance or worse yet it may be impossible to get the wire outside The average time required has been reported to be between 30 and 60 minutes to properly wire an outdoor sensor In addition significant problems with the AutoTrac control have been reported believed to be the result of poor noise immunity in the design of the control when sensor wires pick up interference 2 Simple Mounting Rather than the awkward rectangular cutout that is required to mount the AutoTrac control we ve designed the H1008 to mount much easier We ve encased the sensors in a circular protective shield see Figure 14 requiring only Page 19 of 22 Rev 2 0 63 7048 1998 Honeywell Inc a 34 diameter hole to be cut in the duct Drilling this hole with a uni bit is a snap Simply drill the hole place the control on the duct and secure it with self tapping screws Figure 14 H10
25. ual relationship between furnace run time and outdoor temperature In fact in a single stage heating system in steady state the percentage of burner on time on is linearly related to the difference between the balance point in this context the temperature at which it is warm enough that the furnace never runs and the outdoor temperature To carry this one step further an equation can be derived which expresses on as a function of four variables 1 Outdoor temperature 2 Balance point 3 ASHRAE heating design temperature 4 Oversizing of furnace relative to ASHRAE design temperature Figure 5 shows two examples of this relationship 80 0 60 0 40 0 20 0 0 0 e 0 Furnace Oversize a 100 Furnace Oversize 50 60 70 80 90 20 0 40 0 60 0 Outdoor Temperature deg F 80 0 100 0 Percent On Figure 5 Relationship Between Outdoor Temperature and Percent On The upper line shows an application with a balance point of 55 F where the furnace is exactly matched to the heat loss 0 furnace oversize at the ASHRAE 99 6 design temperature for Minneapolis 16 F In this case the curve is a straight line connecting the balance point at 0 on with the design temperature at 100 on The lower line shows the same application with a furnace with twice the btu output 100 furnace Page 8 of 22 Rev 2 0 63 7048 1998 Honeywell Inc overs
26. umidifier during the warmer periods of the day Again during the entire period the dewpoint tracked just below the window temperature maintaining moisture free windows Page 13 of 22 Rev 2 0 63 7048 1998 Honeywell Inc Digitial Output 80 40 Room Temp 1 70 VV ra A 4 35 Temp Setpoint Window Temp 130 50 A m 25 ze 40 g g w 30 Dewpoint 120 o 5 E 2 gt 20 15 9 Outdoor Temp 10 F 10 0 Humidifier Cycles Fan Cycles G Furnace Cycles W 45 E one JUUUUUUUNI moct BHUI anlai 20 jo 7 O O OOOOOOOOOOOOCOOOOOOOOOOOO eee QQ00g90 scs eoeeaeeeegeoscs eoe aoascSsRoeoeeoeoeoQAoAA 2 Q O Q eeeaeu0 2eeeeeuo0oPef a 822 22 2 02 82 O O O O O O O O O Tr r r r gg T TNR TT NNN NN O Time Figure 10 Field Testing of H1008 Automatic Humidity Control March 11 1998 Minneapolis Minnesota Figure 10 is actual data logged from a home with the H1008 installed during last winter Performance is again excellent with dewpoint tracking just below the window temperature Cycling of the humidifier tracks closely with the outdoor temperature relatively light cycling during the colder portion of the day and heavier cycling during the warmer portion In addition to demonstrating the excellent performance of our humidity control algorithm controlling by dewpoint the field test program also highlighted some serious shortcomings in an approach utilizing control based only
27. was on during the entire recovery period starting at 4 15 a m the sensed RH ranged from 20 to 30 The continuous operation of the humidifier caused the dewpoint in the house to exceed the window temperature for over two hours Contrast this performance with the performance of the Honeywell H1008 shown in Figure 12 where the dewpoint in the house never exceeded the window temperature The difference is clear the better performance of the H1008 is the difference between waking up to dry windows or waking up to wet windows The problems discussed here affect all humidistats that control by sensing only relative humidity including Research Products AutoTrac control The only way around it is to install the humidity control that senses and controls by dewpoint like the Honeywell H1008 Automatic Humidity Control e Installing the Honeywell H1008 Automatic Humidity Control One of the key drivers in the design of the Honeywell H1008 Automatic Humidity Control was to make it simple for the installing contractor This has been accomplished through the use of advanced technology the use of common sense and just plain listening to what the customer wants These are some of the key features that contractors will love 1 Outdoor Sensor Not Required for Most Installations As we ve discussed above for single stage furnaces no outdoor sensor is required This without a doubt will provide the contractor with a huge advantage over their compe

Download Pdf Manuals

image

Related Search

Related Contents

Marantz ST6003SG audio tuner  Page 1 Page 2 Page 3 ティーマックス 一 045~アングルヘッド ` チタン製  A PDP-8 Emulator  Panoshoot User Guide    Mobile-SX Andoroid版マニュアル  MANUAL DE INSTRUÇÕES  取扱説明書(PDF/534KB)  marking notes remarques pour la notation notas para la corrección  pour afficher ce document - EDF Centre de Normalisation  