1. Fig 6 Exploded view of humidifier parts 68 0244 8 HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER Table 8 List Of Replacement Parts For HE220A B HE260A B Humidifiers Exploded View Number Description HE225 Part Number HE265 Part Number Te CI NEON NEON includes water feed tube and nozzle Ps Saddle valve assembly someon someon 12 Automatic Humidity control with H1008A1008 H1008A1008 HumidiCalc Software Base insert assembly includes no 8 above 32001625 003 32001625 004 Hardware Kit for Solenoid Assembly same as Solenoid 32001752 001 32001752 001 valve assembly without the solenoid valve Current Sensing Relay 32001754 001 32001754 001 9 68 0244 68 0244 11 68 0244 IMPROVE YOUR INDOOR AIR WITH A COMPLETE Honeywell envirac e ELITE whole house air quality system ULTRAVIOLET AIR TREATMENT SYSTEM ZAP airborne germs a Z AP e Kill most germs before they recycle through your home Prevent mold spores from growing on your system cooling coils F300E ELECTRONIC AIR CLEANER TRAP airborne particles y Up to 99 efficient at capturing E airborne particles T RAP Effectively REDUCES fungi bacteria mold antigen cat antigen and ragweed pollen antigen that pass through system MOISTURIZE Moisturize parched air Help maintain proper humidity to minimize adverse health effects e Features special antimicrobial agent to prevent surface growt
2. 290 HOF 12 0 IOF 200 ECTO OF HO Above 20 F CTC 0 Table 6 Recommended Frost Factor Settings Humidity Level Recommended Adjustment Insufficient humidity Increase the frost factor dial by one setting Condensation on windows Decrease the frost factor dial by one setting OPERATION Every 1 to 3 Months Depending on Water Quality Use the following procedure to clean the humidifier 1 Disconnect the power and turn off the humidifier water supply 2 Remove the humidifier cover See Fig 5 The HE225A B and HE265A B Humidifiers use the principle that vapor evaporated water is created when warm air blows over a water soaked area As the vapor circulates the relative humidity rises The humidity control monitors the relative humidity and activates the humidifier accordingly The humidifier has a water supply that disburses water over an antimicrobial humidifier pad The warm dry air from the furnace passes over the humidifier pad and collects moisture and them circulates it through the house WATER FEED NOZZLE Humidified air feels warmer and more comfortable so the homeowner may be able to lower the thermostat heating setpoint and save money on heating fuel bills The end result is that the humidifier gives the homeowner a comfortable environment that is also energy efficient HUMIDIFIER RSs PAD ASSEMBLY ERSSIS SSS SS MAINTENANCE A regular maintenance program prolongs the life ofth
3. Customer Relations Honeywell 1985 Douglas Drive North MN10 1461 Golden Valley Minnesota 55422 4386 1 800 468 1502 In Canada Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarbouorgh Ontario M1V 4Z9 International Sales and Service Offices in all principal cities of the world Manufacturing in Australia Canada Finland France Germany Japan Mexico Netherlands Spain Taiwan United Kingdom U S A 68 0244 2 HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER 6 gl 1 of 6 152 DIAMETER M14818 Fig 1 Dimensions of HE225A B in in mm DIAMETER M14819 Fig 2 Dimensions of HE265A B in in mm Approvals Underwriters Laboratories Inc Listing 56 BL Canadian Underwriters Laboratories Inc Listing 56 BL Standard Air Conditioning and Refrigeration Institute Tested Standard 610 Models HE225A TRADELINE and HE265A TRADELINE Bypass Flow through Humidifier package includes humidifier pad mounting template self piercing saddle valve 24 Vac transformer H8908B Convertible Humidity Control HE225B TRADELINE and HE265B TRADELINE Bypass Flow through Humidifier package includes humidifier pad mounting template self piercing saddle valve 24 Vac transformer H1008A Automatic Humidity Control with HumidiCalc Software Accessories Current Sensor Relay part no 32001754 001 C7089H Outdoor Temperature Sensor H8908B Convertible Humidity Control H1008A Automatic H
4. Honeywell HE225A B and HE265A B Honeywell APPLICATION The Enviacaire Elite HE225A B and HE265A B Bypass Flow through Humidifiers use the warm air furnace blower to provide humidification for the whole house U S Registered Trademark Copyright O 2000 Honeywell All Rights Reserved Bypass Flow Through Humidifier PRODUCT DATA FEATURES BENEFITS Antimicrobial coating on pad prevents the surface growth and migration of bacteria mold fungus and algae on the humidifier pad Bold new look with blue and white styling Proven technology used for high performance humidification and enhanced comfort Preassembled for quicker installation Small footprint light weight and reversible components allow easy mounting on either warm air supply or return air duct of any forced air furnace Interior components designed for quick maintenance and service Includes easy to use humidity control that mounts on the wall or duct for more flexible installation Continuous flushing reduces the frequency of maintenance in a hard water installation AIRWATCH Indicator can be installed to remind homeowner to change humidifier pad Five year warranty 68 0244 HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER SPECIFICATIONS Capacity At 120 F 49 C plenum temperature and 0 20 static pressure drop across supply and return HE225A B 12 gallons per day gpd or 46 liters per day Ipd HE265A B 17 gallo
5. e humidifier and provides a more comfortable environment Either hard or soft water can be used in the humidifier Frequency of cleaning depends on the condition of the water CAUTION Voltage Hazard Can cause electrical shock and equipment damage a HOUSING Disconnect power supply before installing or Pe WATER servicing BY PASS SIDEWALL FEED TUBE M14672 Fig 5 Location of humidifier parts IMPORTANT Never oil any part of the humidifier 3 Remove the humidifier pad assembly from the humidifier by grasping the tray and pulling it toward you 4 Pull one side of the humidifier pad assembly frame toward you and remove the tray from the frame 5 Gently pinch the water nozzle catches inward until the water nozzle can be lifted off the tray 6 Slide the antimicrobial humidifier pad out of the frame 7 Carefully scrape any mineral deposits from the tray and frame Be sure the frame drain hole has nothing blocking it 68 0244 6 HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER Check the humidifier pad and if excessive mineral deposits are present replace with a new antimicrobial pad Disconnect the tube from the drain fitting on the bottom of the humidifier housing Clean the drain fitting if necessary Bend the drain tube to loosen any mineral deposits Flush the drain tube with pressurized water a running tap to clean the tube Reattach the drain tube to the drain fitting Slide the humidifi
6. er pad back into the frame IMPORTANT To maintain the antimicrobial properties of the humidifier use only a Honeywell HC22E or HC26E Antimicrobial Pad See Table 8 List of Replacement Parts for appropriate pad Be sure the marked side of the antimicrobial humidifier pad is facing up for proper performance 15 Snap the water nozzle back on the tray Reattach the tray to the frame 17 Place the humidifier pad assembly in the humidifier housing and press until the assembly is completely seated Be careful not to pinch or kink the water feed tube Replace the humidifier cover Verify the humidifier operation by following the steps in the Checkout Procedure section 18 19 End of Humidification Season At the end of the heating season follow steps 1 through 18 from the Every 1 To 3 Months section to clean the humidifier and shut if off IMPORTANT Be sure the humidifier power is off Beginning of Humidification Season Refer to the Checkout Procedure section to complete the humidifier startup Vacation When leaving on vacation turn off the humidifier water supply and the humidity control When returning from vacation turn on the humidifier water supply and reset the humidity control to restart the humidifier CHECKOUT PROCEDURE After winter startup or servicing use the following procedure to check the humidifier operation 1 Turn on the humidifier power and water supply 2 Turn the Convertible Humidity Co
7. h and migration of bacteria mold fungus and algae on the humidifier pad Your Home xpert Honeywell offers one of the broadest families of home solutions in the industry ranging from thermostats zoning ventilation air cleaning humidification to internet enabled home control and wireless WebPAD devices for web surfing and more Check out our offerings on line at www honeywell com yourhome only from Honeywell y yw M14757 Honeywell Home and Building Control Home and Building Control Honeywell Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario MIV 4Z9 Printed in U S A on recycled paper containing at least 10 68 0244 G H 11 00 amp post consumer paper fibers www honeywell com yourhome
8. he automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air The HumidiCalc Software inside the automatic humidity control H1008A a is designed to automatically adjust the humidity level based on indoor temperature and humidity inferred or measured outdoor temperature and the setting of the frost factor dial The frost factor allows for variations in furnace size window insulation and average daily climate temperature The Automatic Humidity Control with HumidiCalc Software requires an initial adjustment period Set the frost factor dial on 5 and use Table 6 to adjust the frost factor only one setting at a time increasing the dial setting for more humidity or reducing the setting if moisture develops on inside windows For more precise humidity adjustment set the frost factor between dial settings Allow two days for the humidity level to subside before making further adjustments Once the proper setting has been found no further adjustment is needed HumidiCalc Software takes over and makes any future adjustments caused by varying outdoor temperatures thus reducing moisture build up on windows while maintaining the optimal humidity level 68 0244 HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER Table 5 Recommended Convertible Humidity Control Settings At Outside Temperature Recommended Setting At Outside Temperature Recommended Setting 20 F
9. ns per day gpd or 65 liters per day Ipd Electrical Ratings 24 Vac 60 Hz 0 5A Humidified Area Humidifier Pad Dimensions See Table 2 Plenum Opening Dimensions Height x Width See Table 3 Summer Shut off Damper Dimensions Height x Width See Table 4 Bypass Duct Opening Diameter 6 in 152 mm Drain Connection 1 2 in 13 mm I D plastic hose connected directly to drain fitting on unit See Table 1 Dimensions Refer to Fig 1 and 2 Table 1 Size Of Area That Can Be Humidified HE225 Area Up To HE265 Area Up To Tight One half 3 000 4 000 Table 2 Dimensions Of Humidifier Pads In In mm HE225 9 13 16 249 9 1 2 241 1 1 2 38 HE265 13 330 10 254 1 1 2 38 Table 3 Dimensions Of Plenum Opening In In mm HE225 9 7 16 241 9 5 16 238 Table 4 Dimensions Of Summer Shut off Damper In In mm HE225 9 3 16 234 8 7 8 226 HE265 12 3 8 314 9 5 16 236 HE265 12 5 8 321 9 3 4 248 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor refer to the TRADELINE Catalog or price sheets for complete ordering number If you have additional questions need further information or would like to comment on our products or services please write or phone 1 Your local Home and Building Control Sales Office check white pages of your phone directory 2 Home and Building Control
10. ntrol to a comfortable setting or the Automatic Humidity Control to the desired frost factor setting for automatic operation The HE225A and HE265A Humidifiers are controlled by the Convertible Humidity Control that is installed either on an interior wall in the living area or on the return air duct Choose the humidity control setting using the combination relative humidity outdoor temperature setting scale on the masos humidity control dial Match the H8908A dial setting to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on inside windows Table 5 can also be used to adjust the humidity control to the recommended setting NOTE As the outside temperature drops the recommended setting is lowered to accommodate the effects of dewpoint These settings should reduce the accumulation of moisture and ice on the windows and in other areas of the house Some indoor activities such as cooking showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on the windows NOTE If this condition persists for more than a few hours set the humidity control to the lowest setting to turn off the humidifier If the condition does not improve ventilate yourhome to remove the moisture The Enviracaire Elite HE225B and HE265B Humidifiers are controlled by the Honeywell H1008A Automatic Humidity Control with HumidiCalc Software T
11. ntrol to the highest setting or place the H1008A Automatic Humidity Control in the Test position and set the thermostat to 10 F 6 C above the room temperature Observe that water is flowing out of the drain hose NOTE The furnace blower must be on for the humidifier to operate Reset the thermostat and Convertible Humidity Control to a comfortable setting or the H1008A Automatic Humidity Control to the desired frost factor setting for automatic operation TROUBLESHOOTING Refer to Table 7 for troubleshooting procedures Table 7 Troubleshooting Procedures What To Look For What To Do Low humidity Furnace blower not operating Rapid air changes Drafts cold air is dry and is an added load to the humidifier Heavy condensation on windows Reset circuit breaker or check for blown fuse Check that the furnace power is on Check all external wiring connections Check the humidity control setting Call a professional heating contractor Keep doors and windows closed Close fireplace damper when not in use Keep exhaust fan running time to a minimum Seal around doors and windows Turn humidity control down low enough to eliminate condensation caused by moisture from bathing mopping cooking etc If moisture persists more ventilation is needed 68 0244 HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER REPLACEMENT PARTS Refer to Fig 6 and Table 8 when ordering replacement parts M14820
12. olenoid inline filter be sure to install the saddle valve handle pointing toward the ceiling NOTE Lightly clean the copper tubing ends with fine sandpaper before making any connections 2 Use 1 4 in O D copper tubing and connect the saddle valve to the inlet side of the solenoid valve AN CAUTION Hazardous Voltage Can cause personal injury or equipment damage Do not use any line connected to an air conditioner a Place the brass compression nut over the copper tubing NOTE Do not over tighten the compression nut Moderate tightness prevents leaking b Slide the brass ferrule over the tubing c Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut 3 Connect a 1 2 in 13 mm drain tube to the humidifier drain fitting and run to a suitable drain NOTE Slope the drain tube downward for correct drainage CHECKING THE INSTALLATION Use the following procedure to check out the humidifier installation 1 Open the saddle valve 2 Set the thermostat setpoint to 10 F 6 C above the room temperature NOTE The furnace blower must be on for the humidifier to operate 3 Set the Convertible Humidity Control to a high setting or place the H1008A Automatic Humidity Control in the Test position 4 Observe the water running out of the drain line to be sure the humidifier is working 5 Check for leaks 6 Reset the thermostat and Convertible Humidity Co
13. the humidifier cover 2 Tape the template in position and trace around the template 3 Remove the template and carefully cut the rectangular opening 4 Disassemble the humidifier remove the cover and take out the humidifier pad assembly See Fig 4 NOTE Sidewalls are interchangeable for either left or right by pass installation To change direction remove the screws holding each sidewall switch sidewall locations and reinstall the screws 5 Position the humidifier housing in the opening be sure it is level so the locking tabs are in place on the lower sheet metal edge of the opening 6 Secure the humidifier housing to the opening at the top and bottom using sheet metal screws 7 Locate the other plenum and cut an opening for a 6 in 152 mm collar 8 Install the 6 in 152 mm collar NOTE Be sure to install a duct damper for summer shutoff on systems with air conditioning 9 Install a 6 in 152 mm diameter duct from the collar to the humidifier NOTE Some installations require a 90 elbow attachment to the collar 10 Seal the duct connections with duct tape NOTE To avoid sagging and stress on the humidifier add support when ducting is longer than 4 ft 120 cm 68 0244 11 Reinstall the humidifier pad assembly in the humidifier housing NOTE Be sure the water feed tube is not pinched or kinked 12 Hinge the cover in place and secure with the thumbscrew located at the bottom of the co
14. umidity Control with HumidiCalc Software software calculates dewpoint to prevent moisture condensation HC22E Antimicrobial Humidifier Pad HE225A B only HC26E Antimicrobial Humidifier Pad HE265 A B only HumidiCalc Humidifier Sizing Software software calculates required humidifier capacity for application PC8900 Control 688 Sail Switch INSTALLATION A WARNING Hazardous Voltage Can cause personal injury or equipment damage Do not cut or drill into any air conditioning line or electrical accessory CAUTION Freezing Water Flooding or Static Pressure Hazard Can cause water damage to home or permanent equipment damage e The humidifier must be located where the ambient temperature is above 32 F and below 160 F 0 C and 71 C Be sure supply plenum static pressure is no greater than 0 3 in w c and water pressure is no greater than 125 psi IMPORTANT To assure optimal product performance be sure the template is level before marking location 1 Determine the best location for the humidifier and draw a level line on the plenum See Fig 3 68 0244 HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER M12248C Fig 3 Typical humidifier installation locations IMPORTANT Mount the humidifier at least 3 in 76 mm above the furnace jacket to allow adequate space for the solenoid valve and drain line Check that there is adequate space above the humidifier to remove and install
15. ver WATER FEED NOZZLE HUMIDIFIER 7 N PAD ASSEMBLY JA HOUSING WATER BY PASS SIDEWALL FEED TUBE M14672 Fig 4 Humidifier components WIRING THE HUMIDIFIER AN CAUTION Hazardous Voltage Can cause personal injury or equipment damage Disconnect the power supply before installing or servicing e On multispeed blower applications do not wire the high voltage side of the transformer to the same power source that services the furnace blower Premature transformer burnout may occur All wiring must comply with applicable local codes ordinances and regulations 1 Mount the transformer in a convenient location 2 Connect wires to the 120V side of the transformer 3 Wire the humidifier solenoid valve current sensing relay or sail switch humidity control and transformer Refer to the humidity control installation instructions for mounting and wiring information NOTE Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed HE225A B AND HE265A B BYPASS FLOW THROUGH HUMIDIFIER PLUMBING THE SADDLE VALVE Hot or cold water either hard or softened can be used in the humidifier 1 Use the self piercing saddle valve included to tap into the water supply line at an appropriate location IMPORTANT The saddle valve is not designed to regulate water flow The valve is either open or closed To prevent debris from clogging the s
Download Pdf Manuals
Related Search
Related Contents
Samsung SHC-735P User's Manual User`s Manual Prédications 2015 - De la Rosa Research Zebra Z-Select 4000T 101.6 x 152.4mm Schmelzklebstoff-Auftragskopf EP 48-VM GF-300/330 overdrive - Jim Dunlop Guide de l`utilisateur pour le téléphone portable GX25 User Manual Copyright © All rights reserved.
Failed to retrieve file