1. 2 SPECI CALGON sico 2 Ordering Information 2 Installation eL 4 Startup and 0 086 0 8 Operation 8 Troubleshooting nicis a 11 68 0258 5 04 W8835 ENVIRAZONE PANEL SPECIFICATIONS Input Ratings Voltage 20 30 Vac 50 60 Hz Power 11 VA nominal Class ll Output Ratings dampers and HVAC equipment 1 5A run 200 000 cycles 30 Vac 3 5A inrush 1 5A run 100 000 cycles 30 Vac 7 5A inrush Humidity Ratings 90 percent at 95 F non condensing Temperature Ratings Shipping 20 to 120 F Operating 40 to 150 F LED SYSTEM mode LEDs 5 used to communicate equipment status Red Heat Heat mode Green Cool Cool mode Yellow Purge Purge mode Green Fan Fan mode Red Em Heat Emergency Heat mode ZONE LEDs 3 used to communicate damper status Green Dampers are open or opening No Color Dampers are closed or closing COM LED 1 used to indicate communication status Flashing Green Panel is transmitting or has received data No color Communications are idle Dimensions 12 3 4 in W x 10 3 4 in H x 1 7 8 in D See Fig 1 ORDERING INFORMATION Finish W8835 Taupe cover olive gray base Mounting Mounts with four screws provided through h
2. M6 cerrado Suministro de energ a cerrado Honeywell z URGE O ENVERA ZONE EM HI di 3 um gt 273 10 3 4 Honeywell m e a e gt 12 3 4 47 1 7 8 520594 Fig 1 Dimensiones W8835 en pulgadas mm Tabla 1 Reguladore recomendados Tipo de reguladore de Honeywell Circular Rectangular Apertura accionada por energ a cierre accionado por energ a para sistemas 2000 cfm Apertura accionada por resorte cierre accionado por energ a para sistemas lt 2000 cfm MARD or RRD ARD or RRD D640 D642 usando el accionador del motor ML6161 20 68 0258ES 04 PANEL ENVIRAZONE 8835 Tabla 2 Accesorios necesarios no incluidos con el panel Rango de desviaci n Accesorio Descripci n cfm Transformadores de 40 VA AT140A1042 Protector de capacidad C7835A1009 Humidificador circular con regulador de SPRD7 300 presi n est tica SPRD8 400 SPRD9 600 SPRD10 750 SPRD12 1200 SPRD14 1800 SPRD16 2400 Humidificador rectangular con regulador de SPRD12x8 1000 presi n est tica SPRD12x10 1200 SPRD12x12 1400 SPRD20x8 1600 SPRD20x10 2000 SPRD20x12 3000 Montaje AIRE DE RETORNO PRECAUCI N Peligro de da o en el equipo No coloque el W8835 dentro del equipo HVAC Col
3. 24 VAC 40 VA TRANSFORMER REQUIRED IF MORE THAN FIVE DAMPERS M31126 Fig 12 Wiring transformer s to panel Wiring C7835 Discharge Air Temperature Sensor Connect wire terminals 1 2 and 3 to the corresponding terminals on either the W8835 EnviraZone panel or any other EnviraCom device such as a thermostat Refer to C7835 Installation Instructions for configuration Multiple devices can be wired in parallel to the each of the 1 2 3 terminals STARTUP AND CHECKOUT 1 Verify that the equipment thermostats transformer and Discharge Temperature Sensor are wired correctly If one transformer is powering the panel install the XFRM jumper If two transformers are powering the panel leave the XFRM jumper in the open position 2 Power up the W8835 Verify that all LEDs except COM illuminate for five seconds The board should then enter the Purge mode with all dampers open The damper LEDs are green to indicate the dampers are open The COM LED begins to blink 3 Press the Purge Override button to terminate the Purge mode 68 0258 04 8 4 Onthe W8835 Panel set the DIP switches a Set DIP switches 1 2 and 7 to assign the appropriate number of heating and cooling stages See Tables 5 and 6 b Configure other DIP switches as necessary to fit the application See Table 6 5 Oneach thermostat enter the Installer Setup procedures using the VisionPRO IAQ Installation Instructions and assign each thermostat a
4. W8835 ENVIRAZONE PANEL W8835A controlling a zone valve or circulator relay panel o o Jumper in place es W8835A FAN RELAY CENTER NOTE FOR THE AQUASTAT AND CIRCULATOR WIRING SEE THE INSTALLATION INSTRUCTIONS FOR THE HYDRONIC RELAY PANEL 5678910 ALL SWITCHES ARE UP DAMPERS ZONE 1 ZONE 2 ZONE 3 M6 M4 Mi MG M4 1 MG M4 M1 ZONE 3 ZONE 1 ZONE 2 CIRCULATOR OR ZONE VALVE RELAY PANEL A R 8222B1067 RELAYS A IF IT IS A HEAT ONLY APPLICATION THE R AND WILL COME FROM A TRANSFORMER RATHER THAN FAN RELAY CENTER IN THAT APPLICATION THE Y AND G SHOWN IN THIS DIAGRAM WOULD NOT BE USED M31127 Fig 13 Wiring reference Zone Valve or Circulator Relay Panel 13 68 0258 04 W8835 ENVIRAZONE PANEL W8835 for hot water zone valves without a hydronic relay panel Cooling Remove Rh Rc jumper W8835A THIS DIAGRAM SHOWS HOW THE W8835 GETS WIRED TO ZONE Y2 VALVES AND AN AIR CONDITIONER FOR HOT WATER HEATING AND FORCED AIR COOLING APPLICATIONS FOR COMPLETE AQUASTAT WIRING SEE THE AQUASTAT INSTRUCTIONS Q Q Q Q Q Q Q Q ZONE 1 M6 M4 M1 O O l TH TR TH TR Honeywell V8043 End switch End switch End switch zone valves Q Q O O O ZONE 2 M6 M4 M1 ZONE 3 M6 M4 M1 R T W T L8124 or L8148 aquastat M31128 Fig 14 Wiring Reference Hot Water Zone Valves 68 0258 04 14 15 W8835 ENVIRAZONE PANEL 68 0258
5. ESPECIFICACIONES Calificacione de entrada Voltaje 20 30 V CA 50 60 Hz Electricidad 11 VA nominal Clase ll Calificaciones de salida reguladores y equipos de cale facci n ventilaci n y aire acondicionado 1 5 A por ciclo 200 000 ciclos 30 V CA 3 5 A de corriente de entrada 1 5 A por ciclo 100 000 ciclos 30 V CA 7 5 A de corriente de entrada Rangos de humedad 9096 HR a 95 sin condensaci n Rangos de temperatura Env o 20 a 120 F En funcionamiento 40 a 150 F LED LED de modo del SISTEMA 5 utilizados para comunicar el estado del equipo Calor rojo modo Heat calefacci n INFORMACI N PARA PEDIDOS Fr o verde modo Cool refrigeraci n Purgado amarillo modo Purge purgado Ventilador verde modo Fan ventilador Luz de emergencia roja modo Emergency Heat calefac ci n de emergencia LED de ZONA 3 utilizados para comunicar el estado del humidificador Verde los humidificadores est n abiertos o se est n abriendo Sin color los humidificadores est n cerrados o se est n cerrando Sin color los humidificadores est n cerrados o se est n cerrando Verde intermitente el panel recibi o est transmitiendo infor maci n Sin color las comunicaciones est n suspendidas Dimensiones 12 3 4 in de ancho x 10 3 4 in de alto x 1 7 8 in de profundidad Vea la Fig 1 Acabado W8835 Cubierta marr n topo con base gris Montaje Montaje mediante cuatro tornillos s
6. 13 68 0258ES 04 PANEL ENVIRAZONE 8835 W8835 PARA V LVULAS DE ZONA DE AGUA CALIENTE SIN UN PANEL DE RELES HIDRONICOS 2 Rh Enfriamiento QUITE EL PUENTE Rh Rc Rc W2 W3 AUX YA W8835A ESTE DIAGRAMA MUESTRA COMO CONECTAR EL W8835 A LAS V LVULAS DE ZONA Y UN AIRE ACONDICIONADO PARA APLICACIONES DE CALEFACCI N DE AGUA CALIENTE Y DE ENFRIAMIENTO DE AIRE FORZADO PARA VER EL CABLEADO COMPLETO DEL AQUASTAT CONSULTE LAS INSTRUCCIONES PARA EL AQUASTAT Q Q Q Q Q Q Q Q O B ZONA 1 M6 M4 M1 ZONA2 M6 M4 1 ZONA 3 M6 M4 1 O O TH TR TH TR TH TR Interruptor Interruptor Interruptor V lvulas de zona terminal terminal terminal V8043 Honeywell R T w Aquastat L8124 o L8148 MS31128 Fig 14 Referencia de cableado v lvulas de zona de agua caliente 68 0258ES 04 14 15 PANEL ENVIRAZONE W8835 68 0258ES 04 PANEL ENVIRAZONE 8835 Automatizaci n y control desenlace Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 customer honeywell com Impreso en E U A en papel reciclado con un m nimo de 10 Marca Registrada en los E U A de fibras de papel postconsumidor C 2009 Honeywell International Inc todos Los Derechos Reservados 68 0258ES 04 Rev 09 09 Honeywell
7. 20 Dampers Wire the 20 Damper to panel as shown in Fig 8 Multiple dampers can be wired in parallel Up to five ARD or ZD dampers can be connected in parallel to one zone If five to ten dampers are connected to the panel an additional 40VA transformer must be connected to the panel MOTOR TERMINALS M6 M4 1 mooro zmvo zZOzzoo DAMPER M14719 Fig 8 Wiring ARD or ZD damper to panel RRD Wire the RRD dampers to the panel as shown in Fig 9 Two or more RRD can be wired in tandem as shown in Fig 10 Up to 12 RRD can be wired to one zone Power the panel with one 40VA transformer if up to 12 dampers are connected to the panel Power the panel with two 40VA transformers if up to 26 RRD are connected to the panel ZONE 1 2 3 ETC M6 M4 M1 M31133 Fig 9 Wiring RRD damper to panel W8835 ENVIRAZONE PANEL ZONE 1 2 3 M6 M4 M1 M31134 Fig 10 Wiring two RRD dampers in parallel MARD Dampers or Dampers using ML6161 Motor Actuator Wire the MARD Damper or other damper using the ML6161 Actuator to the panel as shown in Fig 11 These floating control actuators are controlled as two position devices on the W8835 panel The ML6161 motor causes the damper LED to illuminate green constantly To restore damper position indication mount end Switch 201052B onto the ML6161 ZONE PANEL CONNECTIONS M4 M MARD 9 M20136A Fig 11 Wiring MARD Damper or ML6
8. No damper LEDs are illuminated Incorrect configuration Verify that XFRM jumpers are set correctly Error 35 or 39 message on thermostats Incorrect zone numbers Verify the thermostat zone numbers are set correctly 1 2 3 etc Wait is continuously in the thermostat display Incorrect configuration Verify dip switch 3 is set to conventional Up position If controlling a heat pump verify that thermostats are not configured to lockout the compressor based on outdoor temperature This feature is not used on zoned applications 68 0258 04 Table 12 DIP Switches 1 and 2 Equipment Type DIP 1 DIP2 1 Stage Conventional On up On up 2 Stage Conventional On up Off down 3 Stage conventional Off down On up Heat Pump Off down Off down Table 13 DIP Switches 3 10 DIP Switch Function On Up Default Off Down 3 Type of furnace Conventional non communicating EnviraCom Communicating 4 Purge time Two minutes 3 5 minutes 5 Fan control during purge HVAC controlled Panel controlled 6 Damper control during purge Last zone s calling open during purge all dampers during purge 7 Heat pump compressor One stage Two stages stages 8 Fan control in heat Fan controlled by panel in cool and Fan controlled by panel in heat and HVAC equipment in heat cool 9 Heat pump changeover O Cool changeover B heat changeover Not used
9. V lvula de inversi n enfr calef A PUENTE INSTALADO EN EL CAMPO MS31124 Fig 5 Conexi n de bomba de calor de una sola etapa con calefacci n auxiliar 68 0258ES 04 6 Fig 6 Conexi n de bomba de calor de dos etapas con calefacci n auxiliar LOS SISTEMAS DE CALEFACCI N ENFRIAMIENTO DE UN SOLO TRANSFORMADOR REQUIEREN QUE SE INSTALE UN PUENTE QUE CONECTE Ry Y Rc INSTALADO EN FABRICA EQUIPO HVAC EQUIPO DE r TRANSFORMADOR CALEFACCI N 24 LTRANSFORMADOR ENFRIAMIENTO REL DE LA CALEFACCI N AUXILIAR COMPRESOR DE PRIMERA ETAPA COMPRESOR DE SEGUNDA ETAPA REL DEL VENTILADOR V LVULA DE INVERSI N ENFR CALEF PUENTE INSTALADO EN EL CAMPO MS31125 Fig 7 Conexi n de bomba de calor de dos etapas con calefacci n auxiliar 20 Conecte el regulador ARD 20 al panel tal como se muestra en la Fig 8 Se pueden conectar varios reguladores en paralelo Se pueden conectar hasta cinco reguladores ARD o ZD en paralelo a una zona Si al panel se conectan de cinco a diez reguladores se deber conectar un transformador de 40 adicional al panel TERMINALES DEL MOTOR M6 M4 M1 zceoo l E R F HUMIDIFICADOR 514719 Fig 8 Conexi n humidificador ARD 20 al panel RRD Conecte los reguladores RRD al panel tal como se muestra en la Fig 9 Se pueden conectar dos o m s en tandem tal como s
10. hasta seis zonas o conecte dos W8703 para controlar hasta nueve zonas Conecte los primeros tres termostatos y humidificadores de zona al panel Envirazone W8835 Conecte los humidificadores adicionales al panel W8703 Configure los interruptores DIP en el W8703 para que correspondan con las zonas que va a controlar Consulte las instrucciones de instalaci n del W8703 Conecte los terminales 1 2 y 3 de los termostatos adicionales a los terminales 1 2 y 3 en cualquiera de los paneles 68 0258bES 04 SOLUCI N DE PROBLEMAS Tabla 11 Soluci n de problemas PANEL ENVIRAZONE W8835 S ntoma Posible causa Soluci n Ning n LED est iluminado No hay suministro de energ a en el tablero Controle que haya 24 V 10 en R y C Los transformadores est n fuera de fase Si hay 48 V CAen Ry T1 invierta los cables de T1 y T2 Cable en cortocircuito Controle el interruptor t rmico de circuito Si est caliente existe un cortocircuito en el cableado Los LED del humidificador est n Encendido hacia arriba s pero los dem s LED no est n iluminados Tensi n insuficiente Controle que haya 24 V 10 en R y C Configuraci n incorrecta DIP sea correcta Controle que la configuraci n de los puentes y los interruptores Funcionamiento irregular Interruptor de la calefacci n de emergencia Encendido hacia arriba termostato Apague el interr
11. quelo s lo sobre la pared o en la toma de retorno de aire fr o 1 Coloque los termostatos en cada zona del hogar siguiendo las instrucciones de instalaci n suministradas con cada termostato 2 Monte los humidificadores en la red de conductos utili zando las instrucciones de instalaci n suministradas con cada humidificador 3 Monte el panel EnviraZone W8835 cerca del equipo HVAC col quelo sobre una pared o en la toma de retorno de aire fr o Vea la Fig 2 4 Nivele el W8835 s lo para presentarlo 68 0258ES 04 W8835 MPIADOR DE AIRE MS31121 Fig 2 Ubicaci n de montaje del W8835 Cableado N PRECAUCI N Peligro de alta tensi n Puede ocasionar descargas el ctricas o el equipo Descon ctelo de la fuente de energ a antes de continuar la instalaci n cableado debe cumplir con los c digos las ordenanzas y las reglamentaciones correspondientes Cableado de los termostatos Extienda el cable desde los terminales 1 2 y 3 del termostato hasta los terminales correspondientes en uno de los juegos de terminales del bus EnviraCom Se pueden conectar m s de un termostato u otro dispositivo de comunicaci n a un terminal de bus Ver Fig 3 Equipo de cableado EQUIPO CONVENCIONAL Conecte la calefacci n de la etapa 1 a W1 E la calefacci n de la etapa 2 a W2 y la calefacci n de la etapa 3 a W3 Aux Conecte la refrigeraci n de la etapa 1 a Y1 y la refrigeraci n d
12. sarios para la aplicaci n Vea la Tabla 6 En cada termostato introduzca los procedimientos de la configuraci n de instalaci n mediante las instrucciones de instalaci n de VisionPRO IAQ y asigne un n mero de zona para cada termostato para que corresponda con el humidificador de zona Presione el bot n Discovery descubrir para ejecutar ese modo en el panel de control de la zona En cada termostato introduzca los procedimientos de la configuraci n de instalaci n mediante las instrucciones de instalaci n de VisionPRO IAQ y configure otras opciones pertinentes de la configuraci n de instalaci n No configure las etapas del equipo utilizando la configu raci n de instalaci n Programe el cronograma del termostato si no desea las configuraciones predeterminadas Presione el bot n Discovery descubrir para ejecutar ese modo Configure el termostato de la zona uno en calefacci n y aumente el control de ajuste para la orden de calefacci n a Verifique que el LED de calefacci n est en rojo NOTA El sistema de calefacci n tal vez no se encienda inmediatamente Espere cinco minu tos para que se encienda la calefacci n despu s de la orden de calefacci n b Controle que el LED de la zona dos permanezca en verde c Controle que todos los LED de las otras zonas no est n iluminados d Cambie el modo del termostato de Heat calefac ci n a Off Apagado hacia abajo Configure el termostato de l
13. a minimum of two and one half minutes After this time and any applicable minimum off times imposed by the HVAC equipment It re energizes the equipment when the discharge air has recovered by ten degrees When the high or low limit is exceeded the Heat red or Cool green LED on the DATS flashes When the DATS is in a limit condition the Heat Cool and Purge LEDs on the W8835 panel continue to operate as if the DATS were not turning the equipment off The high and low limit is set on the DATS The high temperature limit is set from 110 F to 160 F with a small screwdriver or using fingers and the low limit is set at 40 F or 48 degrees with a jumper Circuit Breaker Protection A built in thermal circuit breaker protects the EnviraZone panel against shorts in the damper wiring and EnviraCom bus It does not protect against shorts in the HVAC equipment wiring into the panel TROUBLESHOOTING W8835 ENVIRAZONE PANEL When the circuit breaker is tripped none of the LEDs illuminate and the yellow rectangular component located bottom center on the panel is hot to touch Remove power to the panel for at least five minutes to allow the circuit breaker to cool off and reset To eliminate the short verify the dampers and transformer wiring Fan On In Heat The system blower can be set to come on with a call for heat as required for hydro air or electric heat systems Set the blower function using DIP switch 8 When configu
14. predeterminada desconectada y conecte los transformadores T1 y T2 Tabla 9 Configuraci n del tipo de sistema de calefacci n DIP 3 Encendido hacia arriba Tipo de equipo Convencional EnviraCom Apagado hacia abajo Control de humidificaci n deshumidificaci n y ventilaci n panel puede controlar la humedad la deshumidificaci n y la ventilaci n a trav s de mensajes que recibe del termostato VisionPRO IAQ El termostato designado como zona 1 tendr el control de estas funciones Configure este termostato tal como se encuentra en las instrucciones de instalaci n para el termostato Los terminales de humedad deshumidificaci n y ventilaci n son todos terminales de contacto seco los contactos de rel s se cierran cuando est n activos Por lo tanto los dispositivos que requieran control de contacto seco como un ventilador pueden conectarse directamente a los terminales VENT o un humidificador de vapor puede conectarse directamente a los terminales HUM Los dispositivos que deban recibir suministro el ctrico como un regulador de ventilaci n o algunos modelos de humidificadores por evaporaci n son conectados utilizando los terminales VENT o HUM conectados a trav s del terminal R tal como se muestra en la Fig 3 Si utiliza un humidificador TrueSteam Honeywell ajuste la configuraci n N 374 del instalador del termostato VisionPRO IAQ de la zona uno en 3 conecte el terminal GF del Tr
15. zone number to correspond with its zone damper 6 Run Discovery by pressing the Discovery button on the zone control panel 7 Oneach thermostat enter the Installer Setup procedures using the Installation Instructions and config ure other pertinent Installer Setup options Program the thermostat schedule if the default settings are not desired 8 Run Discovery by pressing the Discovery button on the panel 9 SetZone one thermostat to heat and raise the setpoint to call for heat a Verify that the heat LED is red NOTE The furnace heat may not come on immedi ately Allow at least 5 minutes for heat to begin after the thermostat calls for heat b Verify that Zone one LED remains green c Verify that all other zone LEDs are not illuminated d Change thermostat mode from Heat to Off 10 SetZone two thermostat to heat and raise the setpoint to call for heat a Verify that the heat LED is red b Verify that Zone two LED remains green c Verify that all other zone LEDs are not illuminated d Change thermostat mode from Heat to Off 11 Alternatively set a thermostat to Cool lower the setpoint to call for cooling wait five minutes and verify correct operation OPERATION Sequence of Operation When there is no call for heat cool or fan the board is in the idle mode indicated with no system LEDs illuminated see Table 3 Damper LEDs are green to indicate open On a call for heat cool or fan the calling zone
16. 04 Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark Printed in U S A led 2009 Honeywell International Inc n paper containing at least 10 68 0258 04 Rev 08 09 post consumer paper fibers Honeywell Honeywell Panel EnviraZone W8835 INFORMACI N DEL PRODUCTO APLICACI N El panel EnviraZone W8835 controla equipos de una sola etapa de varias etapas convencionales o bombas de calor para calefacci n y refrigeraci n Controla tres zonas y puede ampliarse hasta nueve zonas con dos m dulos adicionales de interfase del humidificador DIM W8703A Para obtener informaci n en Internet http yourhome honeywell com Para obtener asistencia t cnica comun quese al siguiente n mero 1 800 828 8367 Para obtener m s informaci n sobre los productos de Honeywell para mejorar la calidad del aire interior visite http yourhome honeywell com o comun quese con el siguiente n mero 1 800 345 6770 x531 Agencia de Protecci n Ambiental de los Estados Unidos EPA Estados y tendencias de la calidad de aire nacional de 1999 Indoor Air Pollution An Introduction for Health Professionals EPA Imprenta del Gobierno de los EE UU 1994 523 217 81322 IMPORTANTE Lea estas instruccio
17. 161 Actuator to panel Transformer Wire the transformers to the panel see Fig 12 One 40 VA 24 Vac transformer is required to operate the panel and up to five ARD or ZD dampers The transformer is connected to terminals R and C The auxiliary transformer is required if up to ten dampers are connected to the panel It is wired to terminals T1 and T2 If more than five ARD or ZD dampers are required for one zone of if more than ten ARD or ZD dampers are required for the W8835 use the Slave Damper Control Relay SDCR Locate the XFRM jumper shown in Fig 12 These jumpers are shipped in the open disconnected position This is the correct position when two transformers are used When using one transformer to power the panel place the jumpers in the closed position Do this by removing the jumpers and installing them so they cover both of their respective pins If preferred one 75 VA transformer may be used on this panel instead of two 40 VA If this is done leave the jumpers in the open disconnected position and install a jumper between R and T1 Wire the transformer to R and C 68 0258 04 W8835 ENVIRAZONE PANEL N CAUTION Equipment Damage Hazard Incorrect transformer wiring can damage panel Wire transformers in phase when one transformer is wired to R and C and the auxiliary transformer is wired to T1 and T2 REMOVE XFRM JUMPERS FROM PINS WHEN USING TWO TRANSFORMERS A 1997 5 24 40 TRANSFORMER
18. 4386 En Canad Honeywell Limited Honeywell Limit e 35 Dynamic Dr Toronto Ontario M1V 4Z9 Oficinas internacionales de ventas y servico en todas las principales ciudades de mundo Manufactura en Australia Canad Finlandia Francia Alemania Jap n M xico los Pa ses Bajos Taiw n Reino Unido EE 68 0258ES 04 2 Accesorios Para ver los accesorios necesarios consulte la Tabla 2 Los accesorios opcionales incluyen el m dulo de acceso telef nico W8735 para tel fonos con capacidad de mar caci n interna y externa y el m dulo de interfaz para regu lador W8703 para el control de zonas adicionales PANEL ENVIRAZONE W8835 Reguladores Consulte la Tabla 1 para ver los reguladores sugeridos Los reguladores est n conectados a M1 com n 4 abierto y M6 cerrado ver Fig 5 a 8 para las conexiones No conecte m s de cinco reguladores ARD o ZD a una zona individual No conecte m s de cinco reguladores ARD o ZD al panel cuando se utiliza un transformador de 40 VA no conecte m s de diez reguladores ARD o ZD cuando se utilizan dos transformadores de 40 VA Utilice un SDCR rel plano de control de regulador para los reguladores adicionales necesarios Si utiliza reguladores RRD consulte las instrucciones de instalaci n de un RRD para ver el n mero m ximo de reguladores Terminal del motor Acci n del reguladores M1 com n Com n 4 abierto Suministro de energ a abierto
19. Emergency Heat mode Not in Emergency Heat mode Zone 1 2 3 Green Damper is open or opening Damper is closed or closing bAn LED change precedes the corresponding relay change by as much as six seconds Purge Mode At the end of every call for heat or cool the panel enters a Purge mode DIP 4 configures the panel to purge for two default or three and one half minutes DIP switch 5 configures the panel or the HVAC equipment to operate the fan during purge The Purge LED lights to signal that the system is in the Purge mode Pressing the purge override button overrides the Purge mode Unless there is a new call for heat or cool during the Purge mode all dampers are moved to the Open position at the end of purge DIP switch 6 is used if it desired to open all dampers during the Purge mode Table 4 Purge Configuration Individual Zone Fan Control When all zones are satisfied the fan switch of each thermostat controls the fan operation for that zone When the fan setting is On the fan is energized the fan LED illuminates and the dampers close to zones where the fan setting is Auto If there is a call for heat or cool during this time the fan mode ceases and the heat or cool call is honored When the zone calling is satisfied and Purge mode has ended the fan call resumes Single and Multi Stage Conventional Heat Operation The panel can control up to three stages of heating and two stage
20. Honeywell W8835 EnviraZone Panel APPLICATION The W8835 EnviraZone Panel controls single stage multi stage conventional or heat pump heat cool equipment It controls three zones and is expandable up to nine zones with two additional W8703A Damper Interface Modules DIM For Internet access http yourhome honeywell com For technical support call 1 800 828 8367 IMPORTANT Please read these instructions and keep them in your records PRODUCT DATA FEATURES Controls up to three stages heat and two stages cooling of single stage multi stage conventional or heat pump Controls up to three zones and can be expanded up to nine zones with two W8703A DIM Uses VisionPRO IAQ or FocusPRO communicating thermostats for manual or automatic changeover by zone Supports dehumidification humidification and ventilator controls Purge timer protects equipment between calls for heat or cool with choice of panel or HVAC equipment controlled fan System and zone damper LEDs indicate system and damper status Individual zone fan control Supports C7835 Discharge Air Temperature Sensor for capacity control with adjustable high and low limits and equipment failure indication Controls duel fuel equipment when used with an external fossil fuel kit Contents 4 00 6 0 1 Sl SSE
21. More than one thermostat or other communicating device can be connected to a bus terminal See Fig 3 Wiring Equipment W8835 ENVIRAZONE PANEL If separate HVAC equipment transformers are used for the heating and cooling systems such as for an oil furnace wire the heating transformer hot wire to Rh and the cooling transformer hot wire to Rc Locate the Rh Rc jumper above the equipment terminals and remove the jumper to expose the two pins HEAT PUMP EQUIPMENT Connect the 1 terminal to the first stage compressor and the Y2 terminal to the second stage compressor W3 Aux is the CONVENTIONAL EQUIPMENT auxiliary heat and W1 E is the emergency heat If emergency Connect the first stage heat to W1 E second stage heat to W2 heat and auxiliary heat use the same piece of equipment and third stage heat to W3 Aux Wire first stage cooling to Y1 place a jumper from W3 Aux to W1 E and wire it to the resistive and second stage cooling to Y2 See Fig 3 heat equipment See Fig 4 and 5 See Fig 6 and 7 for two SINGLE TRANSFORMER HEATING COOLING SYSTEMS REQUIRE A JUMPER TO BE INSTALLED CONNECTING RH AND RC FACTORY INSTALLED RIO 1 w2 O DOTTED LINES FOR 2 STAGE APPLICATIONS YIO 2 0 CIO TTT EARD 6 R L1 DIP SWITCH SETTINGS 1 SEETABLE ON 2 SEETABLE 1 3 ENVIRACOMFURN NO 12 4 5 6 7 8 m o O stage heat pump equipment C
22. OOL 0 PURGE FAN W8835A HEAT COM ZONE 1 ZONE2 ZONE3 REMOVE JUMPERS IF T1 AND T2 ARE USED LED STATES ZONE LEDS Heat LED Heating Mode On Damper open or opening Cool LED Cooling Mode Off Damper closed or closing Purge Mode MOMENTARY PUSH BUTTONS Fan Mode Boot Clears Microprocessor Em LED Em Heat Mode Purge Override Bypass Purge Mode COMM LED Communications Discovery Initiates Discovery Mode ENVIRACOM PURGE TIME 2 MIN PURGE FAN HVAC PANEL 2 CONVHT STG 24 VOLT 40 VA PURGE DAMPER NOCHG OPEN 9 TRANSFORMER COMPSTAGES 1 2 HEAT FAN HVAC PANEL DAMPER VENT HPCHANGEOVER B XFRM 10 UNUSED DAMPERS ZONE1 M6 M4 M1 ZONE2 M6 M4 M1 ZONE3 M6 M4 M1 SO QO POWER CLOSED POWER CLOSED SPRING OPEN SPRING OPEN ZD DAMPER ZD DAMPER gt 3 1 2 3 3 S OKO 000 POWER CLOSED SPRING OPEN ARD DAMPER M31122 Fig 3 Conventional equipment wiring diagram 5 68 0258 04 W8835 ENVIRAZONE PANEL For dual fuel equipment using heat pump and fossil fuel configure the panel as a heat pump and use a fossil fuel kit Do not use the dual fuel functionality of the VisionPRO IAQ Wiring HVAC Equipment SINGLE TRANSFORMER HEATING COOLING SYSTEMS REQUIRE A JUMPER TO BE INSTALLED CONNECTING Ry AND Rc FACTORY INSTALLED HVAC EQUIPMENT HEATING TRANSFORMER COOLING TRANSFORMER 24 VAC EQUIPMENT AUXILIARY HEAT COMP
23. P Estado Control del ventilador 5 Apagado hacia Control del panel del abajo ventilador en modo Purge purgado 5 Encendido Control del HVAC del ventilador en modo Purge purgado Tabla 6 Configuraci n del regulador de purgado N mero del Humidificador de interruptor DIP Estado purgado 6 Encendido La orden de ltima zona hacia arriba est abierta durante el purgado 6 Apagado hacia Abra todo los abajo humidificadores durante el purgado 68 0258ES 04 PANEL ENVIRAZONE 8835 Control del ventilador para zona individual Cuando todas las zonas se encuentran a gusto el interruptor del ventilador de cada termostato controla el funcionamiento del ventilador de esa zona Cuando la configuraci n del ventilador est en On Encendido el ventilador se activa el LED del ventilador se ilumina y los reguladores se cierran en las zonas donde la configuraci n del ventilador est en Auto autom tico Si en este momento se emite una orden de calefacci n o refrigeraci n el modo de ventilador se detiene y se respeta la orden de calefacci n o refrigeraci n Cuando la zona donde se emiti la orden se encuentre a gusto y el modo de purgado haya terminado se reactiva la orden para hacer funcionar el ventilador Funcionamiento de la calefacci n convencional de una sola etapa y de varias etapas El panel puede controlar hasta tres etapas de calefacci n y dos etapas de refrigeraci n de acu
24. RESSOR FAN RELAY REVERSING VALVE COOLING HEATING A FIELD INSTALLED JUMPER M31124 Fig 4 Wiring single stage heat pump with separate Auxiliary and Emergency Heat SINGLE TRANSFORMER HEATING COOLING SYSTEMS REQUIRE A JUMPER TO BE INSTALLED CONNECTING Ry AND Rc FACTORY INSTALLED HVAC EQUIPMENT HEATING TRANSFORMER COOLING TRANSFORMER A AUXILIARY HEAT COMPRESSOR 24 VAC EQUIPMENT FAN RELAY REVERSING VALVE COOLING HEATING A FIELD INSTALLED JUMPER M31124 Fig 5 Wiring single stage heat pump with Auxiliary Heat 68 0258 04 6 SINGLE TRANSFORMER HEATING COOLING SYSTEMS REQUIRE A JUMPER TO BE INSTALLED CONNECTING Ry AND Rc FACTORY INSTALLED HVAC EQUIPMENT L C 24 HEATING TRANSFORMER Ry EQUIPMENT L COOLING TRANSFORMER Rc EMERGENCY HEAT RELAY AUXILIARY HEAT RELAY FIRST STAGE COMPRESSOR SECOND STAGE COMPRESSOR FAN RELAY REVERSING VALVE COOLING HEATING M31123 Fig 6 Wiring two stage heat pump with separate Auxiliary Heat SINGLE TRANSFORMER HEATING COOLING SYSTEMS REQUIRE A JUMPER TO BE INSTALLED CONNECTING Ry AND Rc FACTORY INSTALLED HVAC EQUIPMENT 24 VAC r HEATING TRANSFORMER EQUIPMENT L COOLING TRANSFORMER AUXILIARY HEAT RELAY FIRST STAGE COMPRESSOR SECOND STAGE COMPRESSOR FAN RELAY REVERSING VALVE COOLING HEATING N FIELD INSTALLED JUMPER M31125 Fig 7 Wiring two stage heat pump with Auxiliary Heat
25. a zona dos en calefacci n y aumente el control de ajuste para la orden de calefacci n a Controle que el LED de calefacci n est en rojo b Controle que el LED de la zona dos permanezca en verde c Verifique que todos los LED de las otras zonas no est n iluminados d Cambie el modo del termostato de Heat calefac ci n a Off Apagado hacia abajo De lo contrario configure el termostato en Cool refrigeraci n disminuya el control de ajuste para la orden de refrigeraci n espere cinco minutos y controle que el funcionamiento sea correcto FUNCIONAMIENTO Secuencia de funcionamiento Cuando no existe una orden de calefacci n refrigeraci n o ventilador el tablero estar en el modo suspendido ning n LED del sistema est iluminado vea la Tabla 3 Los LED del humidificador est n en verde para indicar que est n abiertos EI LED del ventilador se ilumina solo cuando se emite una orden de ventilaci n los dem s humidificadores de zona se cierran y los LED del humidificador correspondiente no se iluminan Funcionamiento del LED COM EI LED COM verde titila mientras el W8835 se comunica con los otros dispositivos EnviraCom EL LED titila r pidamente indica que el dispositivo est en ese momento transmitiendo informaci n en el bus de comunicaci n PANEL ENVIRAZONE W8835 panel W8835 activa el equipo HVAC y se env a aire acondicionado a la zona de la orden El LED de calefacci n rojo de r
26. ble f sil configure el panel como bomba de calor y utilice un juego de combustible f sil No utilice la funcionalidad de combustible dual de VisionPRO IAQ Cableado del equipo HVAC Los sistemas de calefacci n enfriamiento de un solo transformador requieren que se instale un puente que conecte a Ry y Rc instalado en f brica Equipo HVAC Equipo de 24 V CA Transformador calefacci n Transformador enfriamiento LOS SISTEMAS DE CALEFACCION ENFRIAMIENTO DE UN SOLO TRANSFORMADOR REQUIEREN QUE SE INSTALE UN PUENTE QUE CONECTE A Ry Y Rc INSTALADO EN FABRICA EQUIPO HVAC EQUIPO DE TRANSFORMADOR CALEFACCI N 24V CA LTRANSFORMADOR ENFRIAMIENTO REL CALEFACCI N DE EMERGENCIA REL CALEFACCI N AUXILIAR COMPRESOR DE PRIMERA ETAPA COMPRESOR DE SEGUNDA ETAPA REL DEL VENTILADOR V LVULA DE INVERSI N ENFR CALEF MS20599 Calefacci n auxiliar Compresor Rel del ventilador V lvula de inversi n enfr calef A PUENTE INSTALADO EN EL CAMPO MS31124 Fig 4 Conexi n de bomba de calor de una sola etapa con calefacci n de emergencia y calefacci n auxiliar por separado Los sistemas de calefacci n enfriamiento de un solo transformador requieren que se instale un puente que conecte a Ry y Rc instalado en f brica Equipo HVAC Equipo de _ Transformador calefacci n 24 V CA LTransformador enfriamiento Calefacci n auxiliar Compresor Rel del ventilador
27. c Drive Toronto Ontario M1V 4Z9 International Sales and Service Offices in all principal cities of the world Manufacturing in Australia Canada Finland France Germany Japan Mexico Netherlands Spain Taiwan United Kingdom U S A 68 0258bES 04 2 Dampers See Table 1 for suggested dampers Dampers are connected to M1 Common M4 Open and M6 C losed see Fig 5 through 8 for hookups Connect no more than five ARD or ZD dampers to an individual zone Connect no more than five ARD or ZD dampers to the panel when using one 40 VA transformer connect no more than ten ARD or ZD dampers when using two 40 VA transformers W8835 ENVIRAZONE PANEL Use SDCR for additional dampers required If using RRD dampers refer to RRD installation instructions for maximum number of dampers Motor Terminal Damper Action Common M1 Common Open M4 Power Open Closed M6 Power Close Honeywell 00000000 ENVIRAZONE ED 10 3 4 273 Honeywell 1234 ri 1 7 8 324 47 M20594 Fig 1 W8835 dimensions in in mm Table 1 Recommended Dampers Honeywell Damper Type Round Rectangular For systems gt 2000 cfm MARD or RRD For recommended dampers call the Honeywell Zoning Hotline at 1 800 828 8367 For systems 2000 cfm ARD or RRD 20 68 0258 04 W8835 ENVIRAZONE PANEL Table 2 Req
28. damper stays open and the damper LED remains illuminated the other zone dampers close and corresponding damper LEDs do not illuminate The W8835 panel energizes the HVAC equipment and conditioned air is delivered to the calling zone The heat LED red cool LED green or fan LED green illuminates to indicate equipment operation The fan LED illuminates only on a call for fan it does not illuminate during a call for heat or cool When the heat cool call is satisfied the system enters the Purge mode indicated by the Purge LED yellow Damper positions either remain in the same positions as at the end of the call for heat or cool default or open depending on the position of DIP switch 6 After purge all dampers return to the Open position COM LED Operation The green COM LED flickers as the W8835 communicates with the other EnviraCom devices LED blinks rapidly indicates device is currently transmitting information on the communications bus acknowledged a Table 3 LED Indicators W8835 ENVIRAZONE PANEL LED blinks once indicates device received and message LED on constantly indicates panel failure Replace panel LED off constantly indicates a wiring problem LED Color Illuminated Not Illuminated Heat Red Heat call No heat calls Cool Green Cool call No cool calls Purge Amber Purge mode Not in Purge mode Fan Green Fan only call No fan only call Em Heat Red
29. dificadores durante durante el purgado durante el purgado el purgado 7 Etapas del compresor dela Una etapa Dos etapas bomba de calor 8 Control del ventilador durante Ventilador controlado por panel durante Ventilador controlado por panel en la la calefacci n la refrigeraci n y por equipo HVAC calefacci n y refrigeraci n durante la calefacci n 9 Inversi n de la bomba de O inversi n de refrigeraci n B inversi n de calefacci n calor 10 No utilizado 12 68 0258ES 04 PANEL ENVIRAZONE 8835 W8835A CONTROLA UN PANEL DE REL S DEL CIRCULADOR O DE LA V LVULA DE ZONA PUENTE INSTALADO W8835A CENTRO DEL REL DEL VENTILADOR TRANS DE 24 VOLTIOS PARA EL AQUASTAT Y EL CABLEADO DEL CIRCULADOR VEA LAS INSTRUCCIONES DE INSTALACI N PARA EL PANEL DE REL S HIDR NICOS 45678910 TODOS LOS INTERRUPTORES EST N HACIA ARRIBA HUMIDIFICADORES ZONA 1 ZONA2 ZONA3 M6 M4 Mi MG M4 1 MG M4 M1 PANEL DE REL S DEL CIRCULADOR O DE LA V LVULA DE ZONA A R 822281067 RELES A SI ES UNA APLICACI N EXCLUSIVA PARA CALEFACCI N EL R Y VENDR N DE UN TRANSFORMADOR NO DEL CENTRO DEL REL DEL VENTILADOR EN ESTAAPLICACI N LOS TERMINALES Y y G QUE SE MUESTRAN EN ESTE DIAGRAMA NO SE UTILIZAR N Fig 13 Referencia de cableado v lvula de zona o panel de rel s del circulador
30. e la etapa 2 a Y2 Vea la Fig 3 LOS SISTEMAS DE CALEFACCI N REFRIGERACI N DE UN SOLO TRANSFORMADOR REQUIEREN LA INSTALACI N DE UN PUENTE CONECTAR RH Y RC L HEAT _ BURGE INSTALADOS EN LA F BRICA R w1 W2 LED STATES Y1 HeatLED Heating Mode Y2 Cool LED Cooling Mode Fan LED Fan Mode Em Heat LED Em Heat Mode Purge LED Modo Purge purgado COMMLED Communications DIP SWITCH SETTINGS 1 SEETABLE 2 SEETABLE 3 ENVIRACOM FURN 4 PURGETIME 5 PURGEFAN 6 PURGE DAMPER 7 COMP STAGES 8 HEAT FAN 9 HP CHANGEOVER 10 UNUSED VENT VENT DAMPERS ZONE1 M6 M4 M1 ZONE2 M6 M4 M1 EARD 6 HUMIDIFICADOR ZD CON CIERRE ACCIONADO POR ENERG A APERTURA ACCIONADA POR RESORTE HUMIDIFICADOR ARD CON CIERRE ACCIONADO POR ENERG A APERTURA ACCIONADA POR RESORTE ZONE3 M6 M4 M1 ON 1 ON 2 MIN HVAC NO CHG 1 HVAC 0 HUMIDIFICADOR 20 CON CIERRE ACCIONADO POR ENERG A APERTURA ACCIONADA POR RESORTE FM HEAT COM ZONE 1 3 OOO LI PANEL ENVIRAZONE W8835 Si se utilizan transformadores individuales de equipo HVAC para los sistemas de refrigeraci n y calefacci n de igual manera que para un sistema de calefacci n a gas conecte el hilo caliente del transformador de la calefacci n a Rh y el hilo caliente del transformador de la refrigeraci n a Rc Coloque el puente Rh Rc sobre los terminales del equipo y quite el pue
31. e muestra en la Fig 10 Pueden conectarse hasta 12 RRD a una zona Si se conectan hasta 12 reguladores al panel alim ntelo con un transformador de 40 VA Si se conectaron hasta 26 RRD al panel alim ntelo con dos transformadores de 40 VA ZONA 1 2 3 ETC M6 M4 M1 MS31133 Fig 9 Conexi n del humidificador RRD al panel PANEL ENVIRAZONE W8835 ZONA 1 2 3 ETC M6 M4 M1 MS31134 Fig 10 Conexi n de dos humidificadores RRD en paralelo Reguladores MARD o reguladores que utilizan el actuador de motor ML6161 Conecte el regulador MARD u otro regulador que utilice el actuador ML6161 al panel tal como se muestra en la Fig 11 Estos actuadores de control flotante son controlados como dispositivos de dos posiciones en el panel W8835 motor ML6161 hace que el LED del regulador est constantemente iluminado de color verde Para restaurar la indicaci n de posici n del regulador instale el interruptor terminal 201052B en el ML6161 CONEXIONES DEL PANEL DE ZONA Mi M4 M6 MS20136A Fig 11 Cableado del regulador MARD o del actuador ML6161 al panel 68 0258ES 04 PANEL ENVIRAZONE 8835 Transformador Conecte los transformadores al panel ver Fig 12 Se necesita un transformador de 40 VA 24 V CA para hacer 1 funcionar el panel y hasta cinco reguladores ARD o 20 transformador se conecta a los terminales R y C Si se conectan hasta diez reguladores al panel se necesitar el
32. efrigeraci n verde o del ventilador verde se iluminan para indicar el funcionamiento del equipo El LED del ventilador se ilumina s lo durante una orden de circulaci n no se ilumina durante una orden de calefacci n o refrigeraci n Cuando la orden de calefacci n refrigeraci n se ha completado el sistema ingresa en el modo Purge purgado que se indica mediante el LED Purge purgado amarillo Las posiciones del humidificador permanecen iguales tal como estaban al finalizar las rdenes de calefacci n o refrigeraci n predeterminado o en la posici n abierta de acuerdo con la posici n del interruptor DIP 6 Despu s del purgado todos los humidificadores regresan a la posici n abierta EI LED titila una vez indica que el dispositivo recibi y reconoci un mensaje El LED est Encendido hacia arriba constantemente indica una falla en el panel Reemplace el panel EI LED est Apagado hacia abajo constantemente indica un problema de cableado Tabla 3 Indicadores del LED LED Color Heat calefacci n Rojo Orden de calefacci n Sin rdenes de calefacci n Cool refrigeraci n Verde Orden de refrigeraci n Sin rdenes de refrigeraci n Purge purgado mbar Modo Purge purgado No est en el modo Purge purgado Fan ventilador Verde Orden de ventilador nicamente Sin orden de ventilador nicamente Em Heat calefacci n Rojo Modo Emerg
33. ency Heat calefacci n de No est en modo Emergency Heat de emergencia emergencia calefacci n de emergencia Zone 1 2 3 zona 1 2 Verde El humidificador est abierto o se est El humidificador est cerrado o se 3 abriendo est cerrando El cambio de LED precede al cambio del rel correspondiente en aproximadamente seis segundos Modo de purgado Despu s de cada orden de calefacci n o refrigeraci n el panel ingresa al modo de purgado El DIP 4 configura el panel para que purgue durante dos predeterminado o tres minutos y medio El interruptor DIP 5 configura el panel o el equipo de calefacci n ventilaci n y aire acondicionado HVAC para que el ventilador funcione durante el purgado El LED de purgado se enciende para indicar que el sistema se encuentra en el modo de purgado Para anular el modo de purgado presione el bot n de anulaci n manual del purgado Todos los reguladores se pasar n a la posici n abierta al final del purgado a menos que se emita una nueva orden de calefacci n o refrigeraci n durante el modo de purgado El interruptor DIP 6 se utilizar si se desea abrir todos los reguladores durante el modo de purgado Tabla 4 Configuraci n del purgado N mero del interruptor DIP Tiempo de purgado 4 Apagado hacia 3 5 minutos abajo 4 Encendido 2 minutos hacia arriba Tabla 5 Configuraci n del control del ventilador hacia arriba N mero del interruptor DI
34. enza a destellar Protecci n del interruptor de circuito El interruptor t rmico de circuito incorporado protege el panel EnviraZone de cortocircuitos en el cableado del humidificador y el bus EnviraCom No protege de cortocircuitos en el cableado que va del equipo HVAC al panel Cuando el interruptor del circuito est desconectado ninguno de los LED se iluminar n y el componente rectangular amarillo que se encuentra en la parte central inferior del panel est caliente al tacto Corte el suministro de energ a al panel por al menos cinco minutos para permitir que el interruptor se enfr e y reinicie Para eliminar el cortocircuito verifique el cableado del humidificador y del transformador Ventilador Encendido hacia arriba durante la calefacci n ventilador del sistema puede configurarse para que se encienda durante una orden de calefacci n seg n sea necesario para los sistemas de calefacci n el ctricos e Hydro air Configure la funci n del ventilador mediante el interruptor DIP 8 Cuando se configura para una bomba de calor este interruptor DIP no se utiliza Tabla 10 Configuraci n del ventilador durante la calefacci n Interruptor DIP 8 Control del ventilador Apagado hacia abajo Ventilador Encendido durante la calefacci n mediante el panel Encendido hacia arriba Control HVAC del ventilador Adici n de zonas Conecte el W8703 al bus EnviraCom para ampliar el sistema
35. erdo con la demanda del termostato Configure los interruptores DIP 1 y 2 para 1 0 etapas de calefacci n Configure el interruptor DIP 7 para una dos etapas de refrigeraci n Tabla 7 Configuraci n del equipo convencional Tipo de equipo DIP 1 DIP 2 Etapa 1 Encendido Encendido convencional hacia arriba hacia arriba Etapa 2 Encendido Apagado convencional hacia arriba hacia abajo Etapa 3 Apagado Encendido convencional hacia abajo hacia arriba Etapa de DIP7 refrigeraci n Etapa 1 Etapa 2 Encendido hacia arriba Apagado hacia abajo Funcionamiento de la bomba de calor panel puede controlar una o dos etapas del compresor adem s de la calefacci n auxiliar Configure el interruptor DIP 1 y 2 en Apagado hacia abajo y el interruptor DIP 7 en Encendido hacia arriba para un compresor de una sola etapa y en Apagado hacia abajo para un compresor de dos etapas Tabla 8 Configuraci n del equipo de bomba de calor Tipo de equipo DIP 1 DIP 2 Bomba de calor Apagado hacia Apagado hacia abajo abajo Etapas del DIP 7 compresor Etapa 1 Encendido hacia arriba Etapa 2 Apagado hacia abajo Inversi n de la DIP 9 bomba de calor O refrigeraci n Encendido hacia arriba B calefacci n Apagado hacia abajo 68 0258ES 04 10 Conecte la valvula de inversion con el terminal O B del equipo El interruptor DIP 9 co
36. for the thermostat The humidity de humidity and ventilation terminals are all dry contact terminals the relay contacts close when active So devices that need dry contact control like a ventilator can be wired directly to the VENT terminals or a steam humidifier can be wired directly to the HUM terminals Devices that need to be powered like a ventilation damper or some models of evaporative humidifiers are wired using the VENT or HUM terminals wired through the R terminal as shown in Fig 3 If using a Honeywell TrueSteam humidifier configure the zone one VisionPRO IAQ thermostat installer setup 374 to 3 and wire the TrueSteam GF terminal to the HVAC fan terminal and wire the TrueSteam GT terminal to the G on the W8835 NOTE When controlling a steam humidifier set all thermo stats to HEAT Do not set thermostats to AUTO This prevents the panel from humidifying on zone 1 when another zone is calling for cooling Alternatively set zone 1 thermostat Installer Setup 374 to 2 to allow humidification only during calls for heat Discharge Air Temperature Sensor DATS The C7835A1009 Discharge Air Temperature Sensor included in the Y8835 kits is a supply duct mounted temperature sensor probe used to control capacity and prevent high plenum temperatures or coil icing The sensor is wired to the EnviraCom bus using three wires When a high or low limit is reached the panel shuts off the equipment and keeps the fan operating for
37. i n manual o autom tica Si uno o m s termostatos env an una orden de refrigeraci n y al mismo tiempo uno o m s termostatos env an una orden de calefacci n el panel cumplir primero la orden con m s demanda Luego de acuerdo con la demanda de refrigeraci n y calefacci n el panel alterna de manera inteligente entre la calefacci n y la refrigeraci n El sistema intenta satisfacer ambas demandas de calefacci n y refrigeraci n y no da m s prioridad a uno o a otra Discovery Discovery descubrir es un programa autom tico de configuraci n del sistema en donde el panel se configura para funcionar con los controles conectados al bus EnviraCom El panel ingresa en el modo Discovery descubrir cuando se presiona el bot n Discovery descubrir Reinicio del microprocesador Para reiniciar el microprocesador presione el bot n Boot reiniciar El sistema se reinicia e ingresa en el modo Purge purgado Sistema de calefacci n EnviraCom Para los sistemas con comunicaciones EnviraCom integradas configure el panel de la siguiente manera En este caso no se necesita un cableado para equipo convencional ya que el W8835 utiliza el bus EnviraCom de tres cables para controlar el equipo HVAC En estas instalaciones el panel se activa desde el equipo HVAC a trav s de los cables 1 2 y 3 Debido a esto los terminales y C del transformador el W8835 se utilizan En cambio deje los puentes XFMR en su posici n
38. nes y cons rvelas en sus archivos Contenidos ApIICaCIOIU session 1 Caracter sticas us 12 Especificaciones 2 Informaci n acerca de los pedidos 2 Instalaci n 4 Inicio y revisi n 8 Funcionamiento sssrini aaa 9 Soluci n de problemas 12 68 0258ES 04 PANEL ENVIRAZONE 8835 CARACTER STICAS Controla hasta tres etapas de calefacci n y dos etapas de refrigeraci n en equipos de una sola etapa de varias etapas convencionales o bombas de calor Controla hasta tres zonas y puede ampliarse hasta nueve zonas con dos DIM W8703A Utiliza termostatos de comunicaci n VisionPRO IAQ FocusPRO para cambio autom tico o manual zona Admite controles de deshumidificaci n humidificaci n y ventilador Eltemporizador de purgado protege el equipo entre las rdenes de refrigeraci n o calefacci n con la opci n de ventilador controlado por el equipo HVAC o por el panel Los LED del humidificador de zona y del sistema indican el estado del humidificador y del sistema Control del ventilador para zona individual Admite el sensor de temperatura de aire de descarga para control de capacidad con l mites superiores e inferiores ajustables e indicaci n de falla del equipo Controla equipos de combustible dual si se utiliza con un kit de combustible f sil externo
39. nexi n del sensor de temperatura 10 de aire de descarga C7835 Conecte los terminales del cable 1 2 y 3 a los terminales correspondientes el panel EnviraZone W8835 o cualquier otro dispositivo EnviraCom por ejemplo un termostato Consulte las instrucciones de instalaci n de C7835 para ver la configuraci n Se pueden conectar varios dispositivos en paralelo a cada terminal 1 2 y 3 11 68 0258ES 04 8 INICIO Y REVISION Verifique que el equipo los termostatos el transforma dor y el sensor de temperatura de descarga est n conectados correctamente Si un transformador esta suministrando energia al panel instale el puente XFRM Si dos transformadores estan suministrando energia al panel mantenga el puente XFRM la posici n abierta Encienda el W8835 Verifique que todos los LED excepto el LED COM se iluminen durante cinco segundos El tablero debe luego ingresar en el modo Purge purgado con todos los humidificadores abiertos Los LED del humidificador est n en verde para indicar que los humidificadores est n abiertos El LED COM comienza a titilar Presione el bot n Purge Override anulaci n del pur gado para desactivar el modo Purge purgado En el panel W8835 configure los interruptores DIP a Configure los interruptores DIP 1 2 y 7 para que asignen el n mero apropiado de etapas de calefac ci n y refrigeraci n Vea las Tablas 5 y 6 b Configure otros interruptores DIP seg n sean nece
40. nfigura este terminal para que funcione como un terminal de inversi n en O refrigeraci n o B calefacci n Funcionamiento del termostato Funcionamiento de la calefacci n hidr nica EI W8835 es un panel de aire forzado Sin embargo puede conectarse a v lvulas hidr nicas de control tal como se muestra en la Fig 13 Para controlar las v lvulas o los circuladores de un panel hidr nico vea la Fig 14 Equipo de combustible dual El W8835 puede hacer funcionar equipos de combustible dual si se utiliza con un kit de combustible f sil externo Ubique el termostato en las instrucciones del kit de combustible f sil y conecte all los terminales del equipo W8835 Control de la calefacci n de emergencia La calefacci n de emergencia es la utilizaci n de una fuente de calefacci n auxiliar sin utilizar la bomba de calor El W8835 activa el terminal E cuando se emite una orden de calefacci n de emergencia El interruptor del sistema del termostato est configurado en Em Heat calefacci n de emergencia para activar esta funci n Cuando est activa cualquier zona que emita una orden de calefacci n utilizar la calefacci n de emergencia no el compresor El panel activa el W3 como calefacci n auxiliar con los terminales Y1 y Y2 para el control del compresor cuando no est en calefacci n de emergencia Funcionamiento de la conversi n manual y autom tica Cada uno de los termostatos puede configurarse para la invers
41. nte para exponer las dos clavijas EQUIPO DE LA BOMBA DE CALOR Conecte el terminal Y1 al compresor de la etapa 1 y el terminal Y2 al compresor de la etapa 2 W3 Aux es la calefacci n auxiliar y W1 E es la calefacci n de emergencia Si la calefacci n auxiliar y la calefacci n de emergencia utilizan el mismo equipo coloque un puente desde W3 Aux hasta W1 E y con ctelo al equipo de calor resistivo Vea las Figuras 4 y 5 Vea tambi n las Figuras 6 y 7 para un equipo de bomba de calor de dos etapas ZONE 2 ZONE 3 W8835A QUITE LOS PUENTES SI UTILIZA T1 Y T2 ZONE LEDS On Damper open or opening Off Damper closed or closing MOMENTARY PUSH BUTTONS Boot Clears Microprocessor Purge Override Bypass Purge Mode Discovery Initiates Discovery Mode eo o9 ENVIRACOM PANEL OPEN 2 TRANSFORMADOR DE 24 V 40 VA 1 2 CONVHTSTG 1 PANEL 0 DAMPER 1 OOO SENSOR DE AIRE DE DESCARGA C7835A MS31122 Fig 3 Diagrama de cableado del equipo convencional 68 0258 5 04 PANEL ENVIRAZONE 8835 Si el equipo de la bomba de calor tiene un terminal L que se activa en caso de falla de la bomba con ctelo al terminal L del equipo y conecte C en la parte izquierda del panel al terminal com n HVAC Cuando se activa el terminal L los termostatos iluminan la calefacci n de emergencia Para equipos de combustible dual que utilizan una bomba de calor y combusti
42. oles in cabinet back wall anchors provided Wiring Eighteen gauge wire for all equipment and system connections Wiring Connections EnviraCom Four terminal strips each with three terminals labeled 1 2 3 Dampers Three terminal strips labeled M6 Closed M4 Open M1 Common Transformer 1 R hot C Common Transformer 2 T1 hot T2 Common Equipment Rc Rh W1 E W2 W3 Aux Y1 Y2 Humidifier HUM HUM Dehumidifier DHUM DHUM Ventilator VENT VENT Thermostats VisionPROO IAQ TH9421 or FocusPRO THM5320C Thermo stats controls single or multi stage conventional and heat pump equipment Accessories For required accessories see Table 2 Optional accessories include the W8735 Telephone Access Module for telephone dial in and dial out capability and the W8703 Damper Interface Module to control additional zones When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor refer to the TRADELINE Catalog or price sheets for complete ordering number If you have additional questions need further information or would like to comment on our products or services please write or phone 1 Your local Honeywell Automation and Control Products Sales Office check white pages of your phone directory 2 Honeywell Customer Care 1885 Douglas Drive North Minneapolis Minnesota 55422 4386 In Canada Honeywell Limited Honeywell Limit e 35 Dynami
43. red for heat pump this DIP switch is not used Table 10 Fan in heat Configuration DIP Switch 8 Fan Control Off Down Fan on in heat by panel On Up HVAC control of fan Adding Additional Zones Connect one W8703 to the EnviraCom bus to expand the system up to six zones or connect two W8703 to control up to nine zones Wire the first three zone dampers and thermostats to the W8835 Envirazone Panel Wire the additional dampers to the W8703 panels Setthe DIP switches on the W8703 to correspond to the zones being controlled See W8703 Installation Instructions Wire terminals 1 2 and 3 from the additional thermostats to terminals 1 2 and 3 on any of the panels Table 11 Troubleshooting Symptom No LEDs are Illuminated Possible Cause No power to the board Check for 24 Vac 1090 across R and C Action Transformers out of phase If 48 Vac across R and T1 reverse T1 and T2 wires Shorted wire Check thermal circuit breaker If hot a short exists in wiring Damper LEDs on but no other LEDs illuminate on a call for heat cool or fan Insufficient voltage Check for 24 Vac 1090 across R and C Incorrect configuration Check jumpers and DIP switches for correct configuration Heat pump operates incorrectly or not at all Incorrect wiring Verify equipment terminals wiring Incorrect configuration Verify DIP switches configuration
44. s of cooling based on thermostat demand Set DIP Switches 1 and 2 for 1 2 or 3 stages of heat Set DIP switch 7 for one or two stages of cooling Table 6 Purge Damper Configuration DIP Switch Number Status Purge Damper 6 On Up Last zone s calling open during Purge 6 Off Down dampers during Purge DIP Switch Number Status Purge Table 7 Conventional Equipment Configuration 4 Off Down 3 5 minutes purge 1 Stage Cooling 4 On Up 2 minutes purge Equipment Type DIP 1 DIP 2 1 Stage Conventional On Up On Up Table 5 Fan Control Configuration 2 Stage Conventional On Up Off Down DIP Switch 3 Stage Conventional Off Down On Up Number Status Fan Control 2 Stage Cooling 5 Off Down Panel control of fan Cooling Stage DIP7 in Purge Ta Ond 5 On Up HVAC control of fan Purge 2 Stage Off Down 68 0258 04 W8835 ENVIRAZONE PANEL Heat Pump Operation The panel can control one or two compressor stages plus auxiliary heat Set DIP switch 1 and 2 to Off set DIP switch 7 to On for a single stage compressor and to Off for a two stage compressor Table 8 Heat Pump Equipment Configuration Equipment Type DIP 1 DIP 2 Heat Pump Off Down Off Down Compressor Stages DIP 7 1 Stage On Up 2 Stage Off Down Heat Pump Changeover DIP 9 O Cool On Up B Heat Off Do
45. satisfy both the heating and cooling demands and does not lock out one demand in favor of the other 68 0258 04 10 Discovery Discovery is an automatic system configuration program where the panel configures itself to operate with controls connected to the EnviraCom bus The panel enters Discovery when the Discovery button on the panel is pressed Rebooting Microprocessor To reset the microprocessor press and release the Boot button The system reboots and enters the Purge mode EnviraCom Furnace For furnaces with EnviraCom communications built in configure the panel as shown below In this case no conventional equipment wiring is necessary because the W8835 uses the 3 wire EnviraCom bus to control the HVAC equipment In these installations the panel is powered from the HVAC equipment via the 1 2 3 wires Because of this the transformer R and C terminals on the W8835 are not used Instead leave the XFMR jumpers in their default disconnected position and wire the transformer to T1 and T2 Table 9 Furnace Type Configuration Type of Equipment DIP 3 Conventional On Up EnviraCom Off Down Humidity De humidity and Ventilation Control The panel can control humidity de humidity and ventilation by receiving messages from the VisionPRO IAQ thermostat The thermostat designated as zone 1 will have control of these functions Configure this thermostat as found in the installation instructions
46. transformador auxiliar El transformador auxiliar se conecta a los terminales T1 y T2 Utilice el rel plano de control del regulador SDCR si se necesitan m s de cinco reguladores 2 ARD o ZD en una zona o si se necesitan m s de diez reguladores ARD o ZD para el W8835 Ubique los puentes XFRM que se muestran en la Fig 12 Estos puentes se env an en posici n abierta desconectada Esta es la posici n correcta si se utilizan dos transformadores Cuando se utiliza m s de un transformador para alimentar el panel coloque los puentes en posici n cerrada Para hacer esto retire los puentes y 3 col quelos de manera que cubran ambas clavijas respectivas Si lo prefiere puede utilizar un transformador de 75 VA en vez 4 de dos de 40 VA para este panel De ser as deje los puentes en la posici n abierta desconectada e instale un puente entre R y T1 Conecte el transformador a R y C N PRECAUCI N Peligro de da o en el equipo Si conecta incorrectamente el transformador puede da ar el panel Conecte los transformadores en fase cuando un transformador est conectado a R y C y el 6 transformador auxiliar est conectado a T1 y T2 7 Retire los puentes XFRM de los sujetadores cuando utilice Transformador 24 40 8 9 Transformador de 24 V CA 40 VA requerido si hay m s de cinco humidificadores MS31126 Fig 12 Conexi n del transformador o los transformadores al panel Co
47. ueSteam al terminal del ventilador de HVAC y conecte el terminal GT del TrueSteam al terminal G en el W8835 NOTA Cuando est controlando un humidificador de vapor configure todos los termostatos en HEAT calefac ci n No configure los termostatos en AUTO autom tico Esto impide que el panel humidifique la zona 1 cuando otra zona emita una orden de refri geraci n Tambi n puede ajustar la configuraci n del instalador 374 del termostato de la zona 1 en 2 para permitir la humidificaci n solo durante rdenes de calefacci n Sensor de temperatura de aire de descarga DATS El sensor de temperatura de aire de descarga C7835A1009 incluido en los kits Y8835 es una sonda del sensor de temperatura para montaje en conducto de suministro utilizada para controlar la capacidad y para impedir el sobrecalentamiento del plenum o el enfriamiento extremo del serpent n El sensor se conecta al bus EnviraCom por medio de tres cables Cuando se alcanza un l mite m ximo o m nimo PANEL ENVIRAZONE W8835 el panel apaga el equipo y mantiene en funcionamiento el ventilador durante por lo menos dos minutos y medio Despu s de este tiempo y de cualquier tiempo m nimo de apagado impuesto por el equipo de HVAC se vuelve a activar el equipo cuando se ha recuperado el aire de descarga en diez grados Cuando se supera el l mite m ximo o m nimo el LED de Heat calefacci n rojo o de Cool refrigeraci n verde ubicado en el DATS comi
48. uired Accessories Not Supplied with Panel Bypass Rating Accessory Description cfm 40 VA transformers AT140A10428 High and low limit sensor C7835A10092 Round static pressure regulator damper SPRD7 300 SPRD8 400 SPRD9 600 SPRD10 750 SPRD12 1200 SPRD14 1800 SPRD16 2400 Rectangular static pressure regulator damper SPRD12x8 1000 SPRD12x10 1200 SPRD12x12 1400 SPRD20x8 1600 SPRD20x10 2000 SPRD20x12 3000 Supplied in the Y8835 kits RETURN 1 AIR Mounting Equipment Damage Hazard W8835 W8835 Do not mount W8835 inside HVAC equipment Mount only on wall or on cold air return 1 Mount the thermostats in each zone of the living space using the installation instructions provided with each thermostat 2 Mountthe dampers in the ductwork using the installation instructions provided with each damper 3 Mount the W8835 EnviraZone Panel near the HVAC equipment locate it on a wall or on the cold air return See Fig 2 4 Level the W8835 for appearance only 68 0258 04 4 AIR CLEANER M31121 Fig 2 W8835 mounting location Wiring N CAUTION Voltage Hazard Can cause electrical shock or equipment damage Disconnect power before continuing installation Wiring must comply with applicable codes ordinances and regulations Wiring Thermostats Run wire from the Thermostat 1 2 3 terminals to the corresponding terminals on any one of the EnviraCom bus terminal sets
49. uministrados colocados a trav s de los orificios de la parte posterior del gabinete se suministran anclas de expansi n Cableado Cable de calibre 18 para todas las conexiones del sistema y del equipo Conexiones de cableado EnviraCom Cuatro regletas de conexiones cada una con tres terminales designados 1 2 3 Humidificadores Tres regletas de conexiones designados M6 cerrado M4 abierto M1 com n Transformador 1 R calor C com n Transformador 2 T1 calor T2 com n Equipo Rc Rh W1 E W2 W3 Aux Y1 Y2 Humidificador HUM HUM Deshumidificador DHUM DHUM Ventilador VENT VENT Indicador de fallas de la bomba de calor L C Termostatos Los termostatos VisionPROG IAQ TH9421 o FocusPRO THM5320C controlan equipos de una o varias etapas con vencionales o de bomba de calor Cuando compre productos de reemplazo y modernizaci n a su mayorista o distribuidor de TRADELINE refi rase al cat logo o listas de precios de TRADELINE para tener el n mero de pedido completo o especifique 1 N mero del modelo 2 Voltaje Si tiene preguntas adicionales si necesita m s informaci n o si quisiera dar sus comentarios sobre nuestros productos o servicios escriba o llame a 1 Su oficina de ventas local de Automatizaci n y control desenlace consulte las p ginas blancas de su directorio telef nico 2 Honeywell Customer Care 1885 Douglas Drive North Golden Valley MN 55422
50. uptor de la calefacci n de emergencia del La bomba de calor funciona de manera incorrecta o no funciona Cableado incorrecto Controle el cableado de los terminales del equipo Configuraci n incorrecta Controle la configuraci n de los interruptores DIP No se iluminan los LED del humidificador Configuraci n incorrecta correctamente Controle que los puentes XFRM est n configurados Mensaje Com 3 en los termostatos Configuraci n incorrecta Controle que DIP 3 est configurado correctamente Tabla 12 Interruptores DIP 1 y 2 Tipo de equipo DIP 1 DIP2 Etapa 1 convencional Encendido hacia arriba Encendido hacia arriba Etapa 2 convencional Encendido hacia arriba Apagado hacia abajo abajo Etapa 3 convencional Apagado hacia abajo Encendido hacia arriba Bomba de calor Apagado hacia abajo Apagado hacia abajo Table 13 Interruptores DIP 3 a 10 Interruptor Encendido hacia arriba arriba Apagado hacia abajo Apagado DIP Funci n predeterminado hacia abajo abajo 3 Tipo de sistema de Convencional sin comunicaci n Comunicaci n con EnviraCom calefacci n 4 Tiempo de purgado 2 minutos 3 5 minutos 5 Control del ventilador durante Controlado por HVAC Controlado por panel el purgado 6 Control del humidificador La orden de ltima zona est abierta Abra todo los humi
51. wn Wire the reversing valve to the O B equipment terminal DIP Switch 9 configures this terminal to operate as an O cool or B heat changeover terminal Hydronic Heat Operation The W8835 is a forced air panel However it can be wired to control hydronic valves as shown in figure 13 To control valves or circulators on a hydronic panel see figure 14 Thermostat Operation Dual Fuel Equipment The W8835 can operate Dual fuel equipment when used with an external fossil fuel kit Locate the thermostat on the fossil fuel kit instructions and wire the W8835 equipment terminals there Emergency Heat Control Emergency heat is defined as using an auxiliary heat source without using the heat pump The W8835 energizes the E terminal on a call for emergency heat The thermostat system Switch is set to Em Heat to engage this function When active any zone calling for heat uses Emergency Heat not the compressor The panel energizes W3 as auxiliary heat with the Y1 and Y2 for compressor control in when not in emergency heat Manual and Automatic Changeover Operation Each of the thermostats can be set for manual or automatic changeover If one or more thermostats call for cooling while one or more thermostats call for heating the panel attempts to satisfy the greatest demand first Then based on the relative demand for heating and cooling the panel intelligently switches between heating and cooling The system attempts to