Home
HoMedics TE-100 User's Manual
Contents
1. Product Specifications p 17 for more information What is the Fever Alarm The Fever Alarm is a unique feature that will alert the user anytime a temperature reading is 100 F 37 8 C or greater with a visual notice on the display a frowning face and a double beep audio alert visual alert only in memory mode For readings at or above this temperature it is LIKELY that a fever is present Note A temperature reading below 100 F 37 8 C does not mean that a fever is not present Likewise a temperature greater than or equal to 100 F 37 8 C does not guarantee the presence of a fever Each individual s physiology is different and you should monitor your own body temperature to determine your normal temperature range in order to determine when a fever is present Classification of a temperature as a fever also varies by age This product is not intended as a substitute for consultation with a physician Contact your physician if you feel an illness is present with or without a fever A physician should be consulted if any of the following conditions are present Vomiting diarrhea changes in breathing activity or appetite irritability lethargy or unusual sleepiness DEVICE DESCRIPTION LCD Display B Scan Button NOTE C F Toggle Button located behind battery cover Figure 1 DESCRIPTION OF DISPLAY SYMBOLS Temperature ra Ei nin C Celsius a r ia Fahrenheit Mea
2. y sus compa as afiliadas reservados todos los derechos HoMedics es El manu al en una marca registrada de HoMedics Inc y sus compa as afiliadas TheraP es una marca registrada de HoMedics Inc y sus compa as afiliadas Reservados todos los derechos espa ol empieza ias a la p gina 19 year limited warranty IMPORTANT PRODUCT NOTICES AND SAFETY INSTRUCTIONS When using your ear thermometer basic precautions should always be followed Please read and follow all instructions and warnings before using this product Save these instructions for future reference Please note that this product is intended for household use only and should not serve as a substitute for the advice of a physician or medical professional Do not use this device for diagnosis or treatment of any health problem or disease Measurement results are for reference only Contact your physician if you have or suspect any medical problem This ear thermometer is designed for taking temperatures from the ear canal only Do not use it to take rectal oral or axillary temperatures This device is designed for use in human ears only e Use ear thermometer only for its intended use e This ear thermometer should only be used under the supervision of an adult e Prolonged high fever requires medical attention especially for young children e Stand or sit still while taking a temperature e Thermometer should be used in a dry ear canal e Gentle
3. 98 de ASTM 35
4. FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT This warranty does not extend to the purchase of opened used repaired repackaged and or resealed products including but not limited to sale of such products on Internet auction sites and or sales of such products by surplus or bulk resellers Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are repaired replaced altered or modified without the prior express and written consent of HoMedics This warranty provides you with specific legal rights You a have additional rights which may vary from col to country Because of individual country regulations some of the above limitations and exclusions may not apply to you For more information regarding our product line in the USA please visit www homedics com 2006 2008 HoMedics Inc and its affiliated companies all rights reserved HoMedics is a registered trademark of HoMedics Inc and its affiliated companies TheraP is a registered trademark of HoMedics Inc and its affiliated companies All rights reserved IB TE100A Termometro Auricolar Deluxe Lectura en Un Segundo HOMEDICS THERA P TE 100 Garant a limitada por tres a os IMPORTANTES INSTRUCCIONES DE SEGURIDAD Cuando utiliza su term metro auricular siempre se deben seguir ciertas precaucio
5. Note that you should never attempt to clean inside ears however as this may result in damage to the eardrum or surrounding tissues Remove only excess earwax that can be reached with a washcloth Consult a physician if you suspect excess earwax is present within the ear Ear temperatures may be influenced by external factors including e An ear that has been rested upon or covered e General exposure to extreme hot or cold temperatures e Recent bathing or swimming e Use of hearing aids or ear plugs It is recommended that measurement occur at least 20 minutes after these circumstances are no longer present This ear thermometer is for use in human ears only Do not use for oral rectal or axillary temperature measurement 14 SPECIAL SITUATIONS IN WHICH THE EAR THERMOMETER SHOULD NOT BE USED e Pain of any kind is noted during use e Blood or drainage is present in the external ear canal e Deformities of the ear canal or face exist that prohibit the thermometer from being properly inserted into the ear canal e Ear medication or ear drops have been placed in the ear canal e Ear infection of any kind is present e Individual has been bathing or swimming as this may lead to injury of ear tissue as well as inaccurate readings CARE MAINTENANCE amp CLEANING e Clean the unit carefully with a soft dry cloth Do not use any gas strong detergent or solvents to clean the device e Clean the waterproof probe with a cot
6. from the eardrum and surrounding tissue The thermometer takes 512 scans of the eardrum and surrounding tissue in just one second and displays the calculated temperature The temperature displayed represents the measured ear canal temperature converted to the more familiar oral equivalent This is performed using a mathematical adjustment of the ear canal temperature Note that this reading will not necessarily be the same as a temperature measured orally at the same time When consulting a physician it is important to communicate that the temperature reading was taken in the ear and converted to an oral equivalent What is normal body temperature What is a fever Normal body temperature is a range that varies from person to person by age and throughout the day The average normal body temperature is 98 6 F 37 C Fever is defined as a body temperature elevated over an individual s normal body temperature It is important to determine each person s normal body temperature in order to properly assess whether or not a fever is actually present This range can easily be determined by tracking temperatures on a consistent basis using the same ear and measuring at the same time each day This ear thermometer converts the ear temperature to an oral equivalent and meets industry standards regarding temperature accuracy For temperatures between 96 8 F 102 2 F 36 0 C 39 0 C it is accurate to 0 4 F 0 2 C See
7. 102 2 F 86 0 C 39 0 C es preciso hasta 0 4 F 0 2 C Para m s informaci n ver Especificaciones del Producto pg 35 Qu es la Alarma de Fiebre La Alarma de Fiebre es una funci n nica que alerta al usuario cada vez que la lectura de la temperatura excede 100 F 837 8 C por medio de un aviso visual en la pantalla un ce o fruncido y de una alerta sonora de un pitido doble alerta visual solo en modo de memoria Con lecturas encima de esta temperatura es PROBABLE que se presente fiebre Nota Una temperatura debajo de 100 F 37 8 C no quiere decir que no haya fiebre Igualmente una temperatura igual o mayor de 100 F 37 8 C no garantiza que haya necesariamente fiebre 23 La fisiologia de cada individuo es diferente y usted deberia controlar la temperatura de su cuerpo para determinar su rango de temperatura normal y poder asi determinar cuando hay fiebre La clasificaci n de la temperatura como fiebre tambi n var a con la edad Este producto no es entendido como un sustituto de una consulta m dica Si cree que est enfermo con o sin fiebre consulte a su m dico Es necesario consultar al m dico si se presenta cualquiera de las siguientes condiciones v mito diarrea cambios en la respiraci n actividad o apetito irritabilidad condici n let rgica o somnolencia anormal DESCRIPCI N DEL DISPOSITIVO Pantalla LCD Bot n de escaneado ATENCI N La tecla
8. 4 C a 109 4 F 43 C Si tiene o sospecha tener cualquier problema de salud p ngase en contacto con su m dico Aseg rese de que la sonda est posicionada correctamente en la apertura del canal auricular Limpie la sonda con una mota de algod n humedecida con alcohol Rango Operacional El rango de medida es de 93 2 F 34 C a 109 4 F 43 C Si tiene o sospecha tener cualquier problema de salud p ngase en contacto con su m dico Rango Operacional La temperatura operacional es de 60 8 16 C a 104 F 40 C Reemplace la bateria ver C mo Insertar y Reemplazar las Bater as Reemplace la bater a de inmediato ver C mo Insertar y Reemplazar las Bater as CARACTER STICAS DEL PRODUCTO En 4 d gitos cada 0 1 F C 0 4 F 0 2 C entre 96 8 F 102 2 F 36 0 C 39 0 C 0 5 F 0 3 C menos de 96 8 F 36 0 C m s de 102 2 F 39 0 C Rango de Medidas 93 2 F 109 4 F 34 C 43 C Temperatura Operacional 60 8 F 104 F 16 C 40 C Humedad relativa hasta 95 Humedad Operacional sin condensaci n Temperatura de 4 F 122 F 20 C 50 C Almacenamiento Humedad relativa hasta 95 Term metro auricular y bater a estuche Contenido 5 manual de instrucciones Precisi n ATENCI N Estas caracter sticas est n sujetas a cambio sin previo aviso Este term metro auricular satisface los requisitos establecidos en el est ndar E1965
9. Figura 1 MII c AMI F X E e 27 Cuando el term metro auricular est listo la pantalla indicar los resultados de la lectura m s reciente Ahora la unidad est lista para la medida Fig 2 Figura 2 Indica la lectura de la medida Presione y suelte el bot n SCAN otra vez con el term metro auricular fuera del o do Figura 3 Indica que se est tomando y la medida Inserte la punta de la sonda del term metro auricular en el canal auricular en menos de dos segundos Fig 4 Es importante posicionar bien la punta de la sonda en el canal auricular El tiempo de medida de la lectura es de aproximadamente un segundo Figura 4 28 6 Un pitido indicar el fin de la medida La pantalla indica los resultados de la medida de la temperatura Fig 5 En NIGHT MODE la pantalla se ilumina por 5 segundos Figura 5 DN IA F Si la lectura de la temperatura es igual o mayor de 100 F 37 8 C la alarma de fiebre muestra el ce o fruncido y suena un pitido doble para avisar al usuario que probablemente hay fiebre Fig 6 ESTO NO QUIERE DECIR NECESARIAMENTE QUE NO HAY FIEBRE A TEMPERATURAS INFERIORES Para m s informaci n sobre la funci n de Alarma de Fiebre por favor refi rase a la secci n Qu es la Alarma de Fiebre p g 23 Figura 6 Alarma de Fiebre El rango de temperaturas para este term metro es de 50 F 10 C a 122 F 50 C Si
10. HOMEDICS GARANT A LIMITADA POR TRES A OS THERA P HoMedics vende sus productos con la intenci n de que no tengan defectos de fabricaci n ni de mano de H 0 M f D CS O ne Secon d obra por un plazo de tres a os a partir de la fecha de compra original con las siguientes excepciones Por servicio o HoMedics garantiza que sus productos no tendr n defectos de material ni de mano de obra bajo THERA P reparaci n no ee w uso y servicio normales Esta garant a se extiende nicamente a consumidores y no a E ar Th e rm om ete r devuelva esta unidad B al distribuidor Pongase Para obtener servicio para su producto HoMedics envie por correo el producto y su recibo de compra en contacto con fechado como comprobante de compra con franqueo pago a la siguiente direcci n HoMedics Consumer HoMedics Consumer Relations Relations al Service Center Dept 168 a 3000 Pontiac Trai Direcci n Commerce Township MI 48390 HoMedics Consumer Relations No se aceptar n pagos contra entrega Service Center Dept 168 HoMedics no autoriza a nadie incluyendo pero sin limitarse a distribuidores posteriores consumidores 3000 Pontiac Trail compradores del producto a un distribuidor o compradores remotos a obligar a HoMedics de forma alguna Commerce Township m s all de las condiciones aqu establecidas La garant a de este producto no cubre da os causados por MI 48390 uso inadecuado o abuso accidente conexi n de accesorios
11. R PARTE DE LA COMPANIA CON RESPECTO A PRODUCTOS CUBIERTOS POR ESTA GARANT A HOMEDICS NO TENDR RESPONSABILIDAD ALGUNA POR NING N DA O INCIDENTAL CONSECUENTE NI ESPECIAL BAJO NINGUN CONCEPTO a ie REQUERIR MAS QUE LA REPARACI N O CAMBIO DE a ae eee QUE SE cane DEFECTUOSAS D EL PERIODO DE VIGENCIA DE ESTA a NO SE FECTUAR MBOLSOS SI NO HAY PIEZAS DE REPUESTO DISPONIBLES PARA LOS Ha g ECTUOSOS HOMEDICS SE RESERVA EL DERECHO DE REALIZAR SUSTITUCIONES EN VEZ DE REPARAR O CAMBIA Esta garant a no se extiende a la compra de productos abiertos usados reparados embalados otra vez 7 abiertos y vueltos a cerrar incluyendo entre otras cosas la venta de dichos productos en sitios de remate por Internet y o la venta de dichos productos por revendedores o mayoristas Todas y cada una de las garant as cesar n y terminar n inmediatamente con respecto a cualquier producto e rca mismo que est n reparados cambiados alterados o modificados sin el consentimiento previo expl cito y por escrito de oMedics Esta garant a le proporciona derechos legales espec ficos Es posible que usted bl derechos adicionales que pueden variar de un pa s a otro Debido a las regulaciones de ciertos pa ses es posible que algunas de las limitaciones y exclusiones no se apliquen en Su Caso J Por m s informaci n con respecto a nuestra linea de productos en los EE UU visitenos en www homedics com TE 1 00 2006 2008 HoMedics Inc
12. R WARRANTY A HoMedics sells its products with the intent that they are free of defects in manufacture and THERA P workmanship for a period of three years from the date of original purchase except as noted below HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service This warranty extends only to consumers and For service or repair do not does not extend to Retailers return this unit to the retailer i Contact HoMedics Consumer To obtain warranty service on your HoMedics product mail the product and your dated HOMEDICS Relations at sales receipt as proof of purchase postpaid to the following address HoMedics Consumer Relations Address Service Center Dept 168 HoMedics 3000 Pontiac Trail Consumer Relations Commerce Township MI 48390 Service Center Dept 168 le wi 3000 Pontiac Trail No COD s will be accepted gt Commerce Township MI HoMedics does not authorize anyone dam but not limited to Retailers the 48390 subsequent consumer purchaser of the product from a Retailer or remote purchasers to obligate HoMedics in any way beyond the terms set forth herein This warranty does not cover damage caused oy misuse or abuse accident the attachment of any unauthorized Email accessory alteration to the product improper installation unauthorized repairs or cservice homedics com modifications improper use of electrical power supply loss of power ee
13. e product malfunction or damage of an operating part from failure to provide manufacturer s Phone recommended maintenance transportation damage theft neglect vandalism or 1 800 466 3342 environmental conditions loss of use aurin the period the prai is at a repair ay or Business hours otherwise awaiting parts or repair or any other conditions whatsoever that are beyond the 8 30am 5pm ET control of HoMedics Monday Friday This warranty is effective only if the product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it Distributed by HoMedics Printed in China to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY HOMEDICS SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES IN NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY NO REFUNDS WILL BE GIVEN IF REPLACEMENT PARTS
14. etro escan a 512 veces el t mpano y el tejido que lo rodea en s lo un segundo e indica la temperatura calculada La temperatura indicada representa la temperatura del canal auricular convertida al equivalente de temperatura oral m s com n Este se logra por medio de una conversi n matem tica de la temperatura del canal auricular Tome nota que la lectura no ser necesariamente la misma de la temperatura medida oralmente al mismo tiempo Cuando consulte con el m dico es importante informarle que la lectura de la temperatura ha sido tomada en el o do y convertida al equivalente oral Cu l es la temperatura corp rea normal Qu es la fiebre La temperatura corp rea normal var a en un rango que es diferente de persona a persona seg n la edad y el momento en el d a La temperatura promedio normal es de 98 67 37 C Se define la fiebre como una temperatura corp rea elevada por encima de la temperatura corp rea normal del individuo 22 Es importante determinar la temperatura corp rea normal de cada persona para poder determinar si actualmente hay fiebre o no Este rango puede determinarse f cilmente tomando temperaturas con frecuencia constante usando el mismo o do y tomando la medida en el mismo momento del d a Este term metro auricular convierte la temperatura auricular en un equivalente oral y satisface los est ndares industriales sobre la precisi n de la temperatura Para temperaturas entre 96 8 F
15. force should be used when inserting the probe into the ear Excessive force may injure the ear canal or eardrum e Do not expose the monitor to extreme temperature very high humidity or direct sunlight e Handle product with care and avoid dropping e Do not immerse the unit in water or other liquids e Do not disassemble or attempt to repair the unit e When not in use keep thermometer in its storage case and out of the reach of children e Never attempt to insert any object into the probe tip e Please observe the following regarding batteries e Battery liquid can be harmful to the ear thermometer if leakage occurs When the ear thermometer will not be used for an extended period of time three months or more batteries should be removed e A worn battery should be replaced immediately with a new one e Observe caution when inserting battery to avoid insertion with polarities in wrong direction Additional product notices and safety instructions are found in the following sections of this manual e Important notes regarding temperature measurement pg 13 e Special situations in which the ear thermometer should not be used pg 15 e Care maintenance and cleaning pg 15 One Second Ear Thermometer How does this product work This ear thermometer is a delicate and high tech electronic device designed to measure body temperature This unit provides accurate and reliable temperature readings by detecting infrared heat
16. ida no menos de 20 minutos despu s de que estas circunstancias hayan ocurrido e Este term metro auricular est dise ado para uso en el o do humano exclusivamente No lo use para tomar medidas de temperatura rectal oral o axilar SITUACIONES ESPECIALES EN LAS CUALES NO DEBE USARSE EL TERMOMETRO AURICULAR e Se siente cualquier tipo de dolor durante el uso e Hay presencia de sangre o l quido en el canal auricular externo e Se presentan deformidades del canal auricular externo o de la cara que impiden que el term metro pueda quedar propiamente insertado en el canal auricular 32 e Se han aplicado medicinas o gotas para el o do en el canal auricular e Hay presencia de infecci n auricular de cualquier tipo e La persona se ha ba ado o ha nadado puesto que esto puede llevar a lesiones del tejido auricular y a lecturas imprecisas CUIDADO MANTENIMIENTO Y LIMPIEZA e Limpie la unidad cuidadosamente con un pa o suave y seco Para limpiar este dispositivo no use ning n gas detergente agresivo o solventes e Limpie la sonda impermeable con una mota de algod n humedecida con alcohol e No trate nunca de insertar alg n objeto en la punta de la sonda e No sumerja la unidad en agua pues esto la da ar La secci n impermeable de la unidad se limita a la punta de la sonda e El term metro auricular no debe exponerse a temperaturas extremas humedad o luz solar directa e No desarme el term metro auricular Si necesi
17. ip be well positioned within the ear canal Measurement time for the actual reading is approximately one second Figure 4 6 A beep sound will indicate the end of the measurement Results of the temperature measurement will be displayed Figure 5 Figure 5 Moi JA 11 If a temperature reading is greater than or equal to 100 F 37 8 C the fever alarm will display a frowning face and beep twice to alert the user that it is likely that a fever is present Figure 6 THIS DOES NOT MEAN THAT A FEVER IS NOT PRESENT AT A LOWER TEMPERATURE For more information on the Fever Alarm feature please refer to the What is the Fever Alarm section of this manual page 5 Figure 6 Fever Alarm The temperature range of this ear thermometer is 93 2 F 34 0 C 109 F 43 0 C If a measurement is below this range the unit will display Lo Figure 7 If above this range the unit will display Hi Figure 8 Figure 7 Figure 8 12 The unit will display Err if the operating temperature is not within the permissible range for measurement see details in technical section of this manual Figure 9 Figure 9 7 The unit will automatically turn off after 30 seconds of non use IMPORTANT NOTES REGARDING TEMPERATURE MEASUREMENT e The measurement results that users receive are for reference only If users have any health concerns please consult a physician e It is not necessary to perf
18. je este art culo con cuidado y evite dejarlo caer e No sumerja la unidad en agua u otros l quidos e No desarme ni intente reparar esta unidad e Cuando no lo usa guarde el term metro en su estuche y fuera del alcance de los ni os e No trate nunca de insertar alg n objeto en la punta de la sonda e En referencia a las bater as por favor tome nota de lo siguiente e El l quido de las bater as si se presentara alguna p rdida puede ser da ino para el term metro auricular Cuando no se use el term metro auricular para un largo per odo de tiempo tres meses o m s es necesario quitar la bater a e Una bater a usada debe reemplazarse de inmediato por una nueva e Sea cauteloso al insertar las bater as para evitar colocar las polaridades en la direcci n equivocada M s avisos e instrucciones de seguridad se encuentran en las secciones siguientes de este manual e Notas importantes sobre la medida de la temperatura pg 30 e Situaciones especiales en las cuales no debe usarse en term metro auricular pg 32 e Cuidado mantenimiento y limpieza pg 33 21 Termometro Auricolar Deluxe Lectura en Un Segundo C mo funciona este art culo Este term metro auricular es un dispositivo delicado y de alta tecnolog a dise ado para medir la temperatura corp rea Esta unidad proporciona lecturas de temperatura precisas y confiables registrando el calor infrarrojo del t mpano y del tejido que lo rodea Este term m
19. la medida queda debajo de este rango la unidad indica Lo Fig 7 Si queda arriba de este rango la unidad indica Hi Fig 8 29 Figura 7 Figura 8 La unidad indica Err si la temperatura operativa no queda dentro del rango permitido para la medida ver detalles en la secci n t cnica de este manual Fig 9 Figura 9 7 La unidad se apaga autom ticamente si no se usa por m s de 30 segundos NOTAS IMPORTANTES SOBRE LA MEDIDA DE TEMPERATURA e Los resultados de la medida que el usuario recibe son s lo para referencia Si el usuario tiene alguna inquietud sobre su salud favor de consultar al m dico e No es necesario hacer un jal n de oreja o jalar la oreja antes de tomar la medida de la temperatura e Para medidas adicionales el usuario debe esperar 5 segundos entre lecturas para asegurar la precisi n 30 e Use el term metro auricular a temperatura ambiente puesto que las temperaturas exteriores extremas pueden comprometer la precisi n La unidad debe guardarse a la temperatura ambiente Antes del uso la unidad debe encontrarse a temperatura ambiente por no menos de 30 minutos e Entre las lecturas limpie la sonda impermeable con una mota de algod n humedecida con alcohol Siempre mantenga el alcohol para masaje los limpiadores fuera del alcance de los ni os e Se recomienda tomar lecturas m ltiples tres o m s en el mismo o do y usar la lectura m s alta en las siguientes circuns
20. necesario quitar la bater a PARA CAMBIAR LA ESCALA DE TEMPERATURA ENTRE CELSIUS Y FAHRENHEIT Para cambiar entre grados Celsius y Fahrenheit simplemente presione y suelte la tecla F C ubicada detr s de la tapa del compartimiento de la bater a mientras la unidad se encuentra encendida y con la ayuda de un peque o instrumento plano Una vez seleccionada la escala deseada presione el bot n Scan para tomar una lectura nueva o dejar que la unidad se apague autom ticamente y luego enci ndala otra vez para observar la temperatura convertida almacenada en memoria 26 RECUPERAR MEMORIA EN PANTALLA Este term metro almacena autom ticamente las ltimas 10 medidas en memoria Cuando se enciende la unidad la lectura m s reciente aparece autom ticamente en pantalla Cada nueva lectura de temperatura ingresa en memoria como el r cord m s reciente En el modo de memoria aparece una flecha en el ngulo inferior izquierdo con el n mero del r cord en memoria a la derecha como se indica en la ilustraci n de abajo a ri g LIL F Indica la lectura de la medida y el n mero Gi C MO TOMAR UNA LECTURA DE TEMPERATURA 1 Aseg rese siempre que desde el uso anterior se haya limpiado la sonda impermeable con una mota de algod n humedecido con alcohol 2 Presione y suelte el bot n SCAN en el lado del dispositivo Todos los s mbolos en pantalla aparecer n por cerca de un segundo Fig 1
21. nes b sicas Por favor lea y at ngase a todas las instrucciones y advertencias antes de usar este producto Guarde estas instrucciones para referencia futura Por favor tenga en cuenta que este producto est concebido para el uso dom stico y no debe sustituir la opini n de un m dico o de un profesional de la salud No use este producto para el diagn stico o el tratamiento de cualquier problema de salud o enfermedad Los resultados de la medida son para referencia solamente Si tiene o sospecha tener cualquier problema de salud p ngase en contacto con su m dico Este term metro auricular est concebido para tomar la temperatura del canal auricular solamente No lo use para tomar temperaturas rectales orales o axilares Este artefacto est dise ado para uso en el o do humano exclusivamente e Use este term metro s lo para los fines para los cuales ha sido entendido e Este term metro auricular debe usarse s lo bajo la supervisi n de un adulto e Las fiebres elevadas y por largo tiempo requieren atenci n m dica especialmente en ni os peque os 20 e Mientras se toma la temperatura qu dese parado o sentado e El term metro debe usarse s lo con el canal auricular seco e Para insertar la sonda en el o do debe usarse una presi n suave Una presi n excesiva puede lastimar el canal auricular o el t mpano e La pantalla no debe exponerse a temperaturas extremas humedad muy elevada o luz solar directa e Mane
22. nit to turn off automatically and then turn it back on to view the converted temperature stored in memory 8 MEMORY RECALL This thermometer will automatically store the last temperature measurement in memory The most recent reading will automatically display when the unit is turned on Each new temperature reading will replace the temperature stored in the memory When viewing a memory reading the symbol below will appear in the bottom left corner of the display a ari a Indicates l Lis F a memory reading HOW TO TAKE A TEMPERATURE READING 1 Always make sure that the waterproof probe has been cleaned with a cotton swab moistened with alcohol since its previous usage 2 Press and release the SCAN button on the side of the device All display symbols will appear for approximately one second Figure 1 Figure 1 DEN c jar Jm Um F DOa 3 When the ear thermometer is ready the display will next show the results from the last reading The unit is ready for measurement at this point Figure 2 Figure 2 A gt E Indicates a memory reading 4 Press and release the SCAN button again with the ear thermometer outside of the ear An arrow symbol will appear on the display Figure 3 Figure 3 Indicates measurement Cran in progress 10 5 Insert the probe tip of the ear thermometer into the ear canal within two seconds Figure 4 It is important that the probe t
23. no autorizados alteraci n del producto Correo electr nico instalaci n inadecuada reparaciones o modificaciones no autorizadas uso inadecuado de la fuente de cservice homedics com energia electricidad cortes de energ a ca da del producto funcionamiento incorrecto o da o de una pieza de funcionamiento debido al no cumplimiento del mantenimiento recomendado por el fabricante da os Tel fono durante el transporte robo descuido vandalismo condiciones clim ticas p rdida de uso en el per odo 1 800 466 3342 durante el cual el producto est en una instalaci n de reparaci n o a la espera de piezas o reparaci n O Horas de trabajo cualquier otra condici n sin importar cual sea que se encuentre fuera del control de HoMedics 8 30 am 5 00 pm Esta garant a es v lida nicamente si el producto es comprado y operado en el pa s en el cual se compr el Hora del este producto Un producto que requiera modificaciones o adaptaci n para habilitar su funcionamiento en de lunes a vienes cualquier pa s que no sea aqu l para el que fue dise ado fabricado aprobado y autorizado o la reparaci n de productos da ados por estas modificaciones no est n cubiertos bajo esta garant a Distribuido por HoMedics LA GARANT A AQU ESTABLECIDA SER LA NICA Y EXCLUSIVA GARANT A NO HABR NINGUNA OTRA Impreso en China GARANT A EXPRESA NI IMPLICITA INCLUYENDO NINGUNA GARANT A DE COMERCIALIZACI N O APTITUD NI NINGUNA OTRA OBLIGACI N PO
24. orm an ear tug or pull on the ear before taking a temperature measurement e For additional measurements users should wait at least 5 seconds between readings to ensure accuracy e Use the ear thermometer at room temperature as extremes in environmental temperature can impact accuracy Unit should be stored at room temperature Before use the unit must be at room temperature for at least 30 minutes e Clean the waterproof probe with a cotton swab moistened with alcohol between readings Always keep rubbing alcohol cleaners away from children e It is recommended that you take multiple readings three or more in the same ear and use the highest reading in the following special circumstances 13 e When taking the temperature of an infant younger than three months e When taking the temperature of children under the age of three who have special conditions such as compromised immune systems and for whom the absence or presence of a fever is critical e When you are first learning how to use this ear thermometer and until you are obtaining consistent readings Note Slight temperature variations may be observed 0 3 0 5 F or 0 2 0 3 C in consecutive measurements This is common to all types of thermometers Always take the temperature in the same ear as readings may differ from one ear to another The ear must be free from excessive earwax buildup or other obstructions in order to take an accurate reading
25. para alternar entre C F se encuentra detras de la tapa de la bateria 24 DESCRIPCI N DE LOS S MBOLOS EN PANTALLA Temperatura ge Celsius SI F Fahrenheit Indicador ca un de Memoria de Medida Alarma de PA Fiebre Bater a Baja S mbolo K Figura 1 COMO INSERTAR Y REEMPLAZAR BATER AS 1 Retire la tapa de la bater a como se indica en la Figura 1 2 Retire con cuidado la bater a presionando hacia abajo el sujetador de metal que mantiene la bater a en su lugar Para quitar la bater a no use pinzas met licas ni un destornillador 3 Inserte una bater a CR 2032 3 0 V CC con el s mbolo m s hacia arriba tal que indicado en la Figura 2 4 Vuelva a colocar la tapa de la bater a 25 Observe que el term metro indicar por defecto la temperatura de 00 0 F 00 0 C despu s de haberse reestablecido la energ a de la bater a y hasta que se tome una medida La bater a debe reemplazarse cuando aparece el s mbolo de bater a baja en la pantalla Fig 3 Para que el term metro auricular funcione es necesario reemplazar la bater a cuando aparece el s mbolo de bater a baja con el s mbolo Lo Figura 3 Aviso de Bater a Baja ATENCI N No deseche las bater as de litio usadas en la basura Por favor ll velas a cualquier punto de recolecci n oficial Cuando no se use la pantalla para un largo per odo de tiempo tres meses o m s es
26. ry power is low Low battery warning with Lo symbol Battery power is too low for the thermometer to function Product Design Measurement range is 93 2 F 34 0 C to 109 4 F 43 0 C Contact your physician if you have or suspect any medical problems Make sure probe is properly positioned against the opening of the ear canal Clean the probe with a cotton swab moistened with alcohol Product Design Measurement range is 93 2 F 34 C to 109 4 F 43 C Contact your physician if you have or suspect any medical problems Product Design Operating temperature is 60 8 F 16 C to 104 F 40 C Replace battery see Inserting and Replacing Batteries Replace battery immediately see Inserting and Replacing Batteries PRODUCT SPECIFICATIONS Accuracy 0 4 F 0 2 C between 96 8 F 102 2 F 36 0 C 39 0 C 0 5 F 0 3 C less than 96 8 F 36 0 C or greater than 102 2 F 39 0 C Operating Temperature 60 8 F 104 F 16 C 40 C Operating Humidity Relative humidity up to 95 non condensing Storage Temperature 4 F 122 F 20 C 50 C Storage Humidity fsa humidity up to 95 non condensing Ear Thermometer amp Battery Storage Case Contents Instruction Manual NOTE These specifications are subject to change without notice This ear thermometer meets requirements established in ASTM Standard E1965 98 17 LIMITED THREE YEA
27. surement BO Gan Indicator Low Battery Warning INSERTING AND REPLACING BATTERIES 1 Remove the battery cover as shown in Figure 1 Carefully remove the battery by pressing down on the metal clip holding the battery in place Do not use metal tweezers or a screwdriver to remove the battery Insert one CR 2032 3 0 V dc battery with the plus symbol up as shown in Figure 2 Replace the battery cover Note that the thermometer will display a default temperature of 00 0 F 00 0 C after battery power is restored and until a measurement is taken When the low battery symbol appears on the display Figure 3 the battery should be replaced When the low battery symbol appears with the Lo symbol the battery must be replaced in order for the ear thermometer to function Figure 3 Low battery warning om NOTE Do not discard used lithium batteries in trash Please turn in at an official collection point If the monitor will not be used for an extended period of time three months or more please remove battery CHANGING TEMPERATURE SCALE BETWEEN CELSIUS AND FAHRENHEIT To switch between Celsius and Fahrenheit readings simply press and release the F C button located behind the battery compartment cover while the unit is on by using a small flat instrument Once the desired scale is selected press the Scan button to take a new reading or allow the u
28. ta reparaciones refi rase a la secci n de garant a de este manual e El term metro auricular no debe someterse a golpes fuertes no lo deje caer al suelo e Cuando no lo usa guarde el term metro en su estuche y fuera del alcance de los ni os e El term metro ha sido calibrado inicialmente en el momento de su fabricaci n Si este term metro es utilizado siguiendo las instrucciones de uso no require ning n tipo de recalibraci n peri dica Si en cualquier momento dudase de la exactitude de sus mediciones p ngase en contacto con HoMedics Consumer Relations al 1 800 466 3342 33 SOLUCION DE PROBLEMAS CODIGOS DE ERRORES Lecturas consistentes de temperatura baja Lo Lecturas consistentes de temperatura alta Hi Mensajes consistentes de error Err Aviso de Bater a Baja Aviso de bateria baja con simbolo Lo La lectura de la temperatura se encuentra por debajo del rango de medida debajo de 93 2 F 34 C La sonda no esta posicionada correctamente en el o do La sonda impermeable est sucia La lectura de la temperatura se encuentra por encima del rango de medida encima de 109 4 F 43 C La temperatura operacional no se encuentra dentro del rango permitido para la medida La energia de la bateria es baja La energia de la bateria es demasiado baja para que el term metro pueda funcionar 34 Rango Operacional El rango de medida es de 93 2 F 3
29. tancias especiales e Cuando se tome la temperatura de un ni o de menos de tres meses e Cuando se tome la temperatura de ni os de menos de tres meses que presenten condiciones especiales tal como el sistema inmunol gico menoscabado y para los cuales la ausencia o presencia de fiebre es cr tica e Cuando usted aprende por primera vez el uso de este term metro auricular y hasta que logra lecturas consistentes ATENCI N Es posible observar peque as variaciones de temperatura 0 3 0 5 F 0 2 0 3 C en medidas consecutivas Esto es com n en todo tipo de term metro e Tome la temperatura siempre en el mismo o do puesto que la lectura puede variar de un o do a otro 31 e Para tomar una lectura correcta el oido debe estar libre de depositos excesivos de cera y otras obstrucciones Sin embargo observe que usted no deberia tratar nunca de limpiar el interior del o do pues esto podr a resultar en da os al t mpano o al tejido que lo rodea Quite s lo el exceso de cera que puede alcanzarse con un pa o Consulte a su m dico si sospecha tener exceso de cera en el o do e Las temperaturas del o do pueden sufrir la influencia de factores externos incluyendo e El o do sobre el cual se ha descansado o ha estado cubierto e Exposici n general a temperaturas extremas calientes o fr as e Ba o o nataci n recientes e Uso de dispositivos auxiliares para o r o tapones para el o do Se recomienda tomar la med
30. ton swab moistened with alcohol e Never attempt to insert any object into the probe tip e Do not immerse the unit in water as this will result in damage to the unit Waterproof portion of unit is limited to probe tip e Do not subject the ear thermometer to extreme temperatures humidity moisture and direct sunlight e Do not disassemble the ear thermometer If in need of repair refer to the warranty section of this manual e Do not subject the ear thermometer to extreme shocks do not drop on floor e When not in use keep thermometer in its storage case and out of the reach of children e The thermometer is initially calibrated at the time of manufacture If this thermometer is used according to the use instructions periodic re adjustment is not required If at any time you question the accuracy of 15 temperature measurements please contact HoMedics Consumer Relations at 1 800 466 3342 TROUBLESHOOTING ERROR CODES Possible Cause Corrective Action Consistent low Temperature temperature reading is below readings Lo measurement range below 93 2 F 34 0 C The probe is not positioned properly in ear The waterproof probe is dirty Consistent high Temperature temperature reading is above readings Hi measurement range above 109 4 F 43 0 C Consistent error Operating messages Err temperature is not within the permissible range for measurement Low battery warning Batte
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 マルノコ Advantech AIMC-2100 User Manual Sprint Nextel PG86100 User's Manual EV2000 Series Universal Variable Speed Drive User Manual Mayka Wheelchair seat 2 User Manual - aculab chile 東之蛍光灯ンヤ/ナ リ ア取扱脱明書 Bedienungsanleitung MANUALE PER L`OPERATORE MOTOSEGA CS ESTACION METEO PROFESIONAL WMR-88 Copyright © All rights reserved.