1. 3 Set Station Run Times This sets the watering duration required for each station valve PAGE Programming Instructions Programming Example 10 this example 116 lawn areas Program 1 Group 1 are Using pop up sprinklers amp require less frequent watering The vegetables are being watered using drippers on a longer run time with the flower beds pots hanging baskets and pergola areas being watered using micro sprays Two stations are not affected by rainfall these are individually set to OFF During rain these stations are still watered whilst the rest of the system is suspended FRONT LAWN FRONT LAWN VEGETABLES GARDEN BED under eaves BACK LAWN PERGOLA lt WATERING STARTTIME INTERVAL VALVE NUMBER RUN TIME SENSOR minutes ON OFF Start Time 1 4 00 am 2nd Start Time WED 3rd Start Time FRIDAY 4th Start Time Start Time 1 6 00 am 2nd Start Time 3rd Start Time 4th Start Time Start Time 1 2nd Start Time 3rd Start Time 4th Start Time Start Time 1 2nd Start Time 3rd Start Time 4th Start PAGE 4 On WN TON BEN AH OH BONDO ON STATION Programming Instructions Other Functions This controller can also manually run a selected program once or an individual station can be set to run once
2. Use 0 9 to adjust if required Press lt button and the month will flash Use 0 or 9 to adjust Press lt the will flash Use 0 or 9 10 adjust Tip To return to the clock press or turn dial to another position Note When the Auto position ODD or EVEN will be shown PAGE 6 Programming Before proceeding ensure your watering planner has been completed From this you should be aware of which stations are allocated to each program Note Set one program at a time This will ensure that all the values are entered correctly SETTING PROGRAM 1 The program number can only be set changed in the Set Start Times position Step 1 Set Start Times All valves will activate in sequential order for each start time Turn the dial to Set Start Times and ensure that Prog 1 is flashing The display will show Press amp Start 1 willl flash PROG START Press amp the hour will flash Use 0 or 9 adjust Note PM is set correctly Press Bp amp the minutes will flash Use 0 or 9 10 adjust if required Each program has up to four start times and should you require a second start time Press twice amp Start 1 will flash Advance to start 2 by pressing IN The display will show Press and proceed as per setting Start 1 Tip To turn an active start time off turn the dial to the Set Start time
3. 6 Station Model INSTRUCTION MANUAL SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID N10372 WARRANTY Table Of Contents Features Glossary Programming Instructions Introduction Programming Example Other Functions Generaltipsforprogramming Programming Set Current Time amp Correct Day Set Calendar Optional Step 1 Set Start Times Step 2 Set Watering Days Interval Day Selection Individual Day Selection Even Day Selection Step 3 Set Station Run Times Manual Operations System test facility RunA Single Station RunAProgram Other Features Stop Stacking Start Times Automatic BackUp Program Rain Sensor Ready Rain Off Mode Water Budgeting Installation Instructions Mounting The Controller Electrical Hook Up Field Wiring Connections Terminal Block Layout Power Supply Connections Connection Of Valves Pump Hook Up Connections Electrical Characteristics Servicing The Controller Fault Finding Guide Spare Watering Planners anak wo 1 12 12 12 12 13 15 16 16 17 17 18 18 19 19 20 21 22 23 24 25 Features This unit is available as a 6 station configuration Designed for residential and light commercial applications this controller has four separate programs with up to sixteen possible start times a day This ensures efficient watering of different garden or turf areas These different areas may re
4. The delay can be set from 24 hours up to 96 hours and will prevent any automatic starts from occurring for the nominated delay period At the end of the nominated delay time the controller will check the rain sensor again and if it is still reading SENS WET the delay time will override the automatic watering programs and prevent any start time from ocurring This will continue until the rain sensor is DRY and then the automatic programs will start at the next available start time This delay is locked in the controller memory and will activate any time the Rain Sensor is in the WET mode NOTE Stations set at rain sensor OFF will continue to water automatically and any station can be watered manually in system test or rain single station mode PAGE 14 Other Features Rain Sensor Ready cont DELAY FEATURE SETTING RAIN SENSOR DELAY Turn the dial to Rain Sensor Selection Press the 9 button The display will show OFF This means there is NO delay set for the rain sensor The sensor delay will increment in 24 hr blocks so to set the required delay press 6 button amp 24 Sensor Delay Hrs will be shown in the display ane SENSOR DELAY Hrs If a 48 hr sensor delay is required press N again a maximum of 96 hours 4 days can be set To cancel or clear a rain sensor delay Turn the dial to Rain Sensor Selection press the 8 button followed by the 9 button
5. The display will show OFF Sensor Delay Hrs If a delay period has been set amp the rain switch is WET the controller display will show SEN WET and will show the remaining delay time in hours This will continue to override the rain sensor until the delay time has finished counting down or unless you clear the delay feature PAGE 15 Other Features Rain Off Mode To stop the automatic watering cycles during winter turn the dial to the Off position The word Off will appear in the display This means the automatic programs will not come on but the programmed information is still retained in the memory To reactivate the automatic schedule turn the dial back to the Auto Run position NOTE If a rain sensor has been connected the stations set to rain sensor control will be turned OFF automatically when the sensor is wet Water Budgeting The automatic station run times can be adjusted by percentage as the seasons change This will save time and money as the run times can be adjusted quickly in spring winter and autumn to reduce the amount of water used Ensure that the dial is in the Auto Run position and then press the lt and 3 buttons simultaneously The display will show a NU BUDGET Displayed is the word Budget and 100 This represents the current automatic watering run times as being 100 The percentage budget can be set in 25 increments from 25 up to 150 E
6. as follows AC compump 1 2 3 4 5 6 Connection Of Valves Up to two 24VAC Solenoid Valves can be connected to each station output and wired back to the common COM thus Valve wires enter the controller through the rear PAGE 19 Installation Instructions Pump Hook Up Connections Do not attempt to drive a pump starter directly from the controller Pump start 16 provided by connecting 0116 5106 of the coil of a suitable relay to the Master Valve Pump Start output of the controller and the other side to the controller common For systems supplied with water from a pump unused stations must be connected back to the last used station to eliminate the possibilty of the pump running against a closed head Failure to do so could lead to pump damage The diagram shows an 6 station controller with 4 active stations valves PUMP 1 Stations in I PUMPMOTOR 124VACRELAY Un used stalions must 1 MAGNETIC oe 1 STARTER 1 be linked back 1 1 to the last Mains power supply Used station PAGE 20 Electrical Characteristics Power Supply MAINS SUPPLY This unit can run off 50Hz external transformer plugpack with an output of 24VAC 50Hz 1 Amp Plug Pack Model The correct wiring installation for the 24VAC plug pack is shown on page 19 The plug pack model is only suitable for indoor installation Electrical Outputs ELECTR
7. other than the guarantee contained herein The guarantor shall not be liable for any loss from use of the product or incidental or consequential damages including damages to other parts of any installation of which this product is part The guarantee shall not apply to any equipment which is found to have been improperly installed set up or used in any way not in accordance with the instructions supplied with this equipment or to have been modified repaired or altered in any way without the express written consent of the company This guarantee shall not apply to any batteries or accessories used in the equipment covered under this guarantee or to any damage which may be caused by such batteries If the Controller develops a fault the product or panel must be returned in adequate packing with 1 copy of your original invoice 2 description of any fault It is the purchasers responsibility to return the Controller to the manufacturer or their agent by pre paid freight www holmanindustries com au 463 Scarborough Beach Rd Osborne Park 6017 WA Ph 61 8 9204 1011 Fax 61 8 9204 1013 Email sales holmanindustries com au
8. Check field wiring Check transformer Single Station not working Faulty solenoid coil Swap faulty station wire on controller terminal block with known working station wire the faulty valve still does not work on the known working connection then the solenoid coil is faulty The panel may need to be repaired Fuse blows Incorrect wiring or bad wiring joint Check wiring and joints No automatic start Incorrect programming or blown fuse unit works manually check programming Check fuse and field wiring Buttons on Short on keypad or Check instruction book to ensure keypad not Programming not programming correct If keypad responding correct still not responding return panel to supplier or manufacturer System Short on keypad or Check number of start times coming on at too many start times entered on each program If random entered on automatic programming is correct return programs panel to supplier or manufacturer More than 1 Damaged main output Check wiring and swap faulty station coming driver chip station wire s on controller on at once terminal block with known working station wire If the same outputs are still locked on return panel to supplier or manufacturer Pump start Faulty relay or pump Electrician to check voltage on chattering contactor pump relay or contactor Display Display damaged Return panel to supplier or cracked or d
9. ICAL POWER SUPPLY e Input 24Volts AC 50Hz e Electrical Outputs Maximum of 1 0 AMP To Solenoid Valves 24 VAC 50 60 Hz 0 5 AMPs max To the Master Valve Pump Start 24VAC 0 25 AMPs maximum Note Transformer and fuse capacity must be compatible with output requirements e Overload protection Standard 20mm 1 Amp fuse e Power failure 9 Volt block type battery maintains clock and programs for up to 4 weeks e The output circuits should be installed and protected in accordance with wiring rules PAGE 21 Servicing 1116 Controller The controller should always be serviced by an authorized agent Follow these steps 1 2 Turn mains power off to the controller Disconnect 24 Volt power leads from the plug pack at the controller 24VAC terminals Clearly mark or identify all valve wires according to the terminals they are connected 10 1 10 6 This allows you to easily wire them back to the controller maintaining your valve watering sequence Disconnect valve wires from the terminal block Remove the complete unit from the wall Carefully wrap the complete unit in protective wrapping and pack in a suitable box Return to your service agent or the manufacturer Note Tampering with the unit will cancel the Guarantee Replace your controller by reversing this procedure PAGE 22 Fault Finding Guide Symptom No display Possible Cause Faulty transformer Fuse blown Suggestion Check fuse
10. art Times Should you accidently set the same watering start time on more than one program the controller will stack them in sequential order from the lowest number All programmed start times will be watered but the start times will be shunted along Automatic BackUp Program When the battery is not fitted or is flat there is a backup default program in program 1 watering every day at 12 00am for 10 minutes per station A standard 9 volt alkaline block battery should be fitted to the battery snap supplied to maintain the clock accuracy and hold the automatic programs during power outs Tip The display has a warning indicator to let you know when the battery is low or not fitted The word BAT is displayed under the AM PM indicator in the clock mode PAGE 12 Other Features Rain Sensor Ready This feature should only be used when a rain sensor has been connected The controller comes pre fitted with a socket ready to take the HOLMAN Rain Sensor P N CRS1000BC not included which has also been pre fitted with a plug Simply push the plug into the socket and mount the rain switch exposing it to direct weather Turn the dial to Rain Sensor Selection to enable individual stations to be rain sensor ON or OFF The display will show STATION Note all stations are set to OFF at first power up The stations set to OFF will water automatically at all times and the stations set to will
11. be controlled by the rain sensor Eg The stations set to will not water automatically with the rain sensor in the WET mode To set individual stations to ON press 6 button advance by pressing 3 Continue until all stations are set ON for rain sensor control or OFF In the Auto position the display will show TIP If the display is showing g SENS WET and you need to override the rain switch pull the plug connected to the HOLMAN Note Both the System Test and Run Single Station will work on all stations regardless of wether Rain sensor the sensor is wet or dry PAGE 13 Other Features Rain Sensor Ready cont DELAY FEATURE When using the Rain Sensor Ready feature in conjunction with the rain sensor It is possible to set a delay in the controller to stop the automatic programs from activating too quickly This feature is applicable to the stations nominated to be controlled by the sensor EG Set to rain sensor ON and will only occur when the rain sensor is WET The reason for this feature is that the rain sensor itself can dry out due to strong winds or warm temperatures Often the sensor will dry out in 24 hours or less and the automatic watering cycles will start The soil may still be too wet in clay or loam situations and it may be desirable to increase the delay time This can be set at the controller
12. d to a valve should be linked back with a wire to the nearest output with a valve This prevents the pump running against a closed head AC PUMP 1 2 3 4 5 6 Unused stations linked back to Stations in use last used station Run A Single Station Turn the dial to System Test or Run Single Station This will be in the system test mode To manually run a single station once STATION RUN TIME press 0 button to kick the unit into the other mode The display will change from 2 minutes to 10 minutes STATION RUN TIME To adjust the run time use 0 Or ths advance the next station press the button PAGE 11 Manual Operations cont Run A Program To manually run a complete program once for the run times as set in the automatic schedule Turn the dial to the Run Program position Prog 1 will be shown in the display To run program 1 leave or advance to program 2 by pressing Note if a rain switch is connected and the display shows SEN WET the stations set to rain sensor ON will not activate However individual stations can be watered by using the Run Single Station facility Other Features Stop To stop an automatic or manual watering schedule turn the dial to the Off position Tip For automatic watering remember to turn the dial back to the Auto Run position The Off position will stop any watering from occuring Stacking St
13. dd Even Day Selection Optional In some regions users are only allowed to water their gardens on ODD dates if their house number is ODD or on EVEN dates when their number is EVEN This controller allows this to be done simply by setting the relevant selection of ODD or EVEN and setting the current date into the controller The controller will account for leap years If you require the ODD EVEN day option simply press the button until ODD is shown Press the button and EVEN will be shown This feature may be required in areas where water restrictions are enforced Note Remember to set the 365 day calendar when setting the clock or this feature will be out of sequence Step 3 Set Station Run Times This is the length of time that each station valve is set to water on a particular program Maximum watering time is 12 hours 59 minutes for each station A station can be assigned to 1 or 2 programs if required Turn the dial to the Set Station Run Times position and the display will show the following STATION RUN TIME a are tus PROG This means station 1 has a default run time of 10 minutes in program 1 Station 1 will be flashing PAGE 9 Programming Step 3 Set Station Run Times Continued To adjust the Run time in minutes press 3 and use 0 Or set the run time in hours press Eap 0 will appear and flash To adjust use 0 Or 9 If not required
14. from 1 minute up to 12 hours and 59 minutes During winter the automatic programs can be suspended to prevent watering while it is raining A test facility for checking the valves and sprinklers is also provided General tips for easy programming Tips to help eliminate programming confusion Complete the spare watering planner When setting one push of the button will increment one unit Holding one button down will fast scroll through units During programming only the flashing values are able to be set use the 0 Or buttons Pressing will scroll forward through the settings in an orderly sequence Pressing lt will scroll back to previous settings and settings can be changed Increase Value Scroll N Scroll gt 9 Turn dial to required setting Decrease Value Basic Control Operation PAGE 5 Programming Set Current Time amp Correct Day Turn the dial to Set Clock Calendar position The hour will be flashing Use 0 Or to adjust Note AM PM must be set correctly Press the button and the minutes will flash Use 6 or 9 to adjust Press 3 and the day of the week will flash Use 0 Or to set correct day Set Calendar Optional Note The calendar only needs to be set when selecting ODD EVEN day watering in areas where water restrictions may require this feature Press lt button until the year month and day are shown The year will be flashing
15. ing the programmed Socket amp Rubber Plug RSR information Rain Sensor Cable Socket Simple push in pull out plug amp socket configuration Terminal Cover Compatible with HOLMAN Remove Rain Sensor CRS1000BC terminas or solenoid valve PAGE 2 wires Programming Instructions Introduction This controller has been designed with four separate programs to allow different garden areas to have their own individual watering requirements A program is basically a method of grouping stations valves with similar watering requirements to water on the same days These stations will water in sequential order from the lowest number at the start time or times nominated and on the days selected The key elements when programming your controller are e Grouping the stations valves Group together garden areas which have similiar watering requirements Examples are Turf Areas Flower Beds Pergola Undercover Areas or Vegetables These different groups require individual settings e Planning out your watering program Complete your individual watering planner supplied at the back of this book e Setting the current time and correct day of the week e Setting an automatic program Use the following 3 steps to program each group 1 Set Start s This sets the time of the day when the watering program will commence 2 Set Watering Days These are the nominated days when the automatic system will be active
16. ng and pump or master valve hook ups PAGE 17 Installation Instructions Field Wiring Connections PREPARATION 1 Prepare wires for hook up by cutting the wires to the correct length and stripping approximately 6 0mm a inch of insulation from the to be connected to the controller 2 Ensure terminal block screws are loosened sufficiently to permit easy access for wire ends Insert stripped wire ends into the clamp aperture and tighten screws Do not over tighten as this may damage the terminal block 3 maximum of 0 5 Amps may be supplied by any output Check the inrush current of your solenoid coils before connecting more than two valves to any one station Terminal Block Layout The terminal block is laid out as follows Fuse located under battery cover USE ONLY 1 AMP FUSE M 205 AC AC compump 1 2 3 4 5 6 GLOSSARY AC 24VAC Power Supply COM Common valve wire input PUMP Master valve or pump start active wire ST1 to 516 Station Valve active wire connection PAGE 18 Installation Instructions Power Supply Connections The controller itself can run off a 240V AC to 24V AC external transformer It is recommended that the transformer is not connected to a 240V AC supply which is also servicing or supplying motors i e Air conditioners pool pumps refrigerators etc Lighting circuits are suitable as a power source Connections to the unit are
17. press p and advance to station 2 by pressing the 0 button Continue until all the stations in Program 1 have been set with a run time or if a station or stations are not required to be active in this particular program ensure that the run time is set to OFF Note To set a station to OFF Use 9 when the RUN TIME is flashing This completes the setting up procedure for automatic watering of Program 1 Should you need a second program Turn the dial to Set Start Times and Prog 1 will flash Press 0 and change to program 2 position and follow the same 3 steps to set an automatic watering program 1 Set Starts 2 Set Watering Days 3 Set Station Run Times Tip Remember to return the dial to the Auto Run position after completing the set up of an automatic program This will ensure that the automatic cycles will take place PAGE 10 Manual Operations System Test Facility Turn the dial to System Test or Run Single Station This is a dual function position STATION RUN TIME The display will show 1 vse Use this feature amp that your valves amp sprinklers are working correctly The unit will run all stations in sequential order The factory preset time of 2 minutes per station can NOT be adjusted IMPORTANT TIP the water supply is from a pump system it is critical to ensure all outputs are connected to a valve Any output NOT connecte
18. quire individual watering programs and often use different types of sprinklers Examples Turf areas generally use pop up sprinklers and require less frequent but heavier watering However flower beds use micro sprays and require more frequent watering The valves stations which water similar garden areas are often grouped together and put into the same program as they need to be watered on the same days These stations valves will water in sequential order from the lowest number at the start time or times nominated and on the days selected Maximum watering duration for a station valve is 12 hours and 59 minutes This controller has three types of watering day options Either interval watering from everyday to every 15th day individual day selection per program or a 365 day calendar for ODD EVEN day watering An innovative feature of this controller is the Rain Sensor Ready RSR technology This allows individual stations to be controlled by a rain sensor In this way garden areas that are subject to rain can have their irrigation suspended during wet periods while areas under cover can continue to be watered PAGE 1 Glossary INDOOR CONTROLLER MODEL Battery Cover Selection Dial LCD Display Remove cover Used for Easy to read to fit 9V block operations amp display battery programming RSR PROGRAM START 6 Fuse Location Programming Remove Buttons cover to Used for access adjust
19. s position Select the start number required using the 0 button and then press until the hour is flashing Use 0 Or until OFF is shown Tip OFF position is between 12 and 1pm PAGE7 Programming Step 2 Set Watering Days This unit has interval watering or individual day selection from everyday to every 15th day or a 365 day calendar with odd even day selection in areas where water restrictions require this feature Turn the dial to Set Watering Days Interval Day Selection RUN The display will show Interval 1 will be flashing This means that watering will occur every day To change the interval day press the 0 button Examples Interval 2 means watering will take place every second day 3 means watering will take place every third day etc Interval watering can be set from everyday to every 15th day The Run Day refers to the number of days before the next watering program will occur Individual Day Selection Press the button This is the selectable day option The display will show This refers to Mon being Day 1 To turn Monday off press MON TUE WED THU FRI SAT SUN 9 button 16246 active 16246 as is advance to Tuesday day 2 by pressing the button Again press the 9 button to set the day off if required followed by 3 to advance Continue until all seven days have been set on 0 or off 9 PAGE 8 Programming O
20. uring transportation manufacturer missing segments PAGE 23 Spare Watering Planner Spare Watering Planner VALVE NUMBER VALVE NUMBER 2 e a n ET 2 e RUN TIME SENSOR minutes ON OFF WATERING INTERVAL WATERING INTERVAL RUN TIME SENSOR START TIME minutes OFE START TIME Start Time 1 Time 4th Start Start Time 1 2nd Start 3rd Start 3 he 2 Start 1 200 Start Start 1 Time Time Time Time PAGE 24 PAGE 25 Start Time 1 2nd Start BONDO UPR WNH HB OP WHNY OW STATION BONDO UN BONDO UAN PWN OW BR WD STATION 3rd Start Blo elo aio elo Sle Eee 2 3 353 2 3 3 7 3 2 3 I O HID Io Io a Sl S 5 A gt a z Your Guarantee The manufacturer Guarantee to the original purchaser that any product supplied by the manufacturer will be free from defects in materials and workmanship for a period of three years from the date of purchase Any product found to have defects in material or workmanship within the period of this Guarantee shall be repaired or replaced by the manufacturer FREE OF CHARGE The guarantor does not guarantee the fitness for a particular purpose of its products and does not make any guarantee expressed or implied
21. xample 50 reduces watering by half To adjust in 25 increments use 0 Or buttons To return to the clock press the 8 and 3 buttons simultaneously The display will show the word Budget to indicate that the water budgeting feature is in use PAGE 16 Installation Instructions Mounting The Controller This controller unit is an INDOOR MODEL and MUST not be exposed to rain or water ingress If the controller needs to be outdoors you can purchase a HOLMAN outdoor weatherproof box P N COBOX to mount the controller inside This box is available from your irrigation supplier Install the controller near 240V AC mains outlet preferably located in a house garage or other covered area For ease of operation eye level placement is recommended Drive one 8 screw into the wall leaving about 4mm of the screw exposed If necessary use a toggle bolt or masonary shield Hang the controller from the key slot located in the back of the case Make sure the head is properly seated inside the controller case Additional screws may be inserted through the holes in the lower corners of the controller case Electrical Hook Up WARNING 1 All electrical work must be carried out accordance with these instructions following all applicable Local State and Federal codes or warranty will be void 2 Disconnect mains power supply before maintenance work to controller or valves and when connecting and disconnecting field wiri