Hobart Q Series User's Manual
Contents
1. BFH Pees u lo ul aaa a a DEFROST DURATION Fig 16 Initiating a Manual Defrost During normal Operation Mode with the SET CLOCK light Cancelling a Defrost Cycle Press the SET button until the SET CLOCK PROGRAM and DEFROST ON lights are lit then release the SET button and all three lights go off for two seconds After that all three lights begin to blink The number of blinks of a light corresponds to the programmed value for that light A three second pause follows the last blink before the cycle repeats The Review Mode s sequence of blinking lights Fig 18 repeats ten times to give you plenty of chances to count the number of blinks for each light Review Mode can be stopped at any time by pressing the SET button for 3 seconds when the SET button is released normal Operation Mode returns with the SET CLOCK light blinking rapidly The SET CLOCK light blinks from 1 to 12 times to indicate the TIME CLOCK HOUR If the final blink for the hour count remains on for two seconds it indicates PM if the final blink for the hour count is a normal blink it indicates AM While the SET CLOCK light is blinking the HOUR the PROGRAM light blinks from 0 to 11 times to indicate the TIME CLOCK MINUTES to the nearest 5 minutes after the hour 0 blinks 0 minutes 1 blink 5 minutes 2 blinks 10 minutes 11 blinks 55 minutes While the SET
2. asees REACHAN Q SERIES REACH IN FOOD STORAGE CABINETS HOBART FORM 14580 Rev L Jan 2002 Installation Operation and Care of Q SERIES REACH IN FOOD STORAGE CABINETS SAVE THESE INSTRUCTIONS GENERAL The Q Series Reach In Food Storage Cabinets are available as low temperature 0 F medium temperature 38 F refrigeration units or hot food storage cabinets 180 F maximum They may be ordered as one two or three section cabinets A variety of optional cabinets is available These include Two or three section cabinets with a combination of medium and low temperature sections or medium temperature and hot food storage sections two or three section cabinets equipped with optional SAFE T THAW equipment for safe rapid thawing at medium temperatures convertible models which by setting a selector switch will operate as either a low temperature or medium temperature unit and single section over under cabinets which feature a medium temperature and a low temperature unit one on top of the other INSTALLATION UNPACKING AND ASSEMBLY Immediately after unpacking the reach in check for possible shipping damage If this unit is found to be damaged after unpacking save the packaging material and contact the carrier within 15 days of delivery Prior to installation test the electrical service to assure that it agrees with the specifications on the machine data plate located in the upper left corner insid
3. Connected Reach Ins WARNING ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND OR OTHER LOCAL ELECTRICAL CODES WARNING DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT Make electrical connections per the wiring diagram supplied with the unit PRESTART CHECKS REFRIGERANT LINES Check for tubing shifts due to shipping that would cause operating noise wear or leaks SELECTOR SWITCH Convertible Models Only The selector switch should be set to the proper Position To gain access to the switch remove the front trim panel Fig 2 by raising it up to clear the retaining slots and out Set the switch on the proper position Refrigerator or Freezer and replace the trim panel OPERATIONAL CHECK The refrigeration and defrost cycles should be checked for proper operation and the thermometer s should also be checked for correct temperature indication before product is stored in the cabinet DEFROST TIMER On freezer units set the defrost timer as described in Operation OPERATION CONTROLS Refrigeration TEMPERATURE CONTROL The temperature control is set at the factory but local conditions may necessitate slight adjustment To adjust the temperature control lift up and remove the front trim panel Fig 2 Turn the control knob A Fig 8 a small amount at a time Turn
4. accidental movement The utility base is secured to the cabinet with four bolts one at each corner The utility base is mounted at the factory With the cabinet in its final installed and leveled position apply a bead of NSF approved sealant not supplied around the bottom Access covers secured with screws are provided on the left side and front for attaching the power supply cord to a floor outlet underneath the cabinet Curb The cabinet may be installed on a curb without legs or casters the typical curb must be recessed a minimum of 1 from the frontofthe cabinet and rear if itis a pass through to allow room for the hinges Compressor Mounts Some Q Series units have the compressor specially mounted to help prevent damage during shipment If the compressor is mounted on shipping blocks remove the shipping blocks before operating the compressor If the compressor is mounted on springs refer to the tag attached to the compressor Condensate Evaporator A Series cabinets except for remote or over under units are equipped with an automatic condensate evaporator and require no drain connection ELECTRICAL CONNECTIONS Cord Connected Reach Ins 120 Volt 60 Hertz 1 Phase WARNING THIS MACHINE IS PROVIDED WITH A THREE PRONGED GROUNDING PLUG THE OUTLET TO WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE CONTACT AN ELECTRICIAN ELECTRICAL CONNECTIONS Permanently
5. switch the circulating fans on and reverse the refrigerant valve so the warm refrigerant flows to the inside of the cabinet and the cool refrigerant goes to the le coil When the cabinet has warmed to 40 F the thermostat tums off the warming The cabinet continues to cycle heat on at 36 F and off at 40 F When the frozen product has lost its ability to reduce the cabinet temperature to 36 F heat from the fan motors will gradually cause the cabinet temperature to climb to 45 F At this point the thermostat will reverse mode again to normal refrigeration cycle cooling on at 40 F and off at 36 F Circulating fans do not work during normal refrigeration mode All the apparatus works automatically without adjusting the factory settings NOTE To reduce the drying effect of the fans blowing air over foods it is recommended that food stored in the Safe T Thaw be covered CONTROLS Hot Food Storage Units Fig 10 The ON OFF switch contains a pilot light which glows whenever the switch is ON Tum the switch OFF whenever the cabinet is not in use The ON OFF switch is not a disconnect switch ALWAYS DISCONNECT POWER AT THE SOURCE TO SERVICE THE UNIT The temperature control dial which has a marked OFF position no heat is used to select the temperature at which the food will be held When this dial is OFF the air circulating fans continue to run The HUMIDITY control dial is used to regulate the humidity level inside the
6. CLOCK light is blinking the HOUR and the PROGRAM lightis blinking the MINUTES the DEFROST ON light blinks from 0 to 11 times to indicate the DEFROST DURATION setting to the nearest 5 minutes 0 blinks minutes 1 blink 5 minutes 2 blinks 10 minutes 11 blinks 55 minutes After the ten blinking sequences are done or after Review Mode has been stopped normal Operation Mode returns with the SET CLOCK light blinking rapidly king rapidly Press the MANUAL DEFROST button for about 3 seconds until the DEFROST ON light comes on The Defrost Cycle is started and continues for the amount of time programmed for DEFROST DURATION page 8 While a Defrost Cycle is in progress the DEFROST ON lightis lit A Defrost Cycle that is in progress can be terminated by pressing the MANUAL DEFROST button for 3 seconds The DEFROST ON light goes off The normal DEFROST SCHEDULE continues to operate as programmed Em If the Defrost Timer s Battery Loses Power If the SET CLOCK PROGRAM and DEFROST ON lights are all blinking the backup power supply battery to the Defrost Timer has weakened Estimated battery life is 10 years The timer can continue to function normally after the battery has weakened if the timer is reprogrammed If a power outage occurs and is later restored after the battery has weakened the following three things happen The defrost clock resumes as if it were 12 00 midnight The
7. The Defrost Time Clock is set at the factory to the current time of day for Central Standard Time The Defrost Duration is preset atthe factory to run for 25 minutes Also the Defrost Schedule is preset at the factory to start a defrost cycle four times each day 812 AM 8 AM 2 PM and 8 PM The factory preset defrost schedule is active during normal Operation Mode if all 24 switches are OFF Switches are OFF when tabs are positioned to the left Fig 12 The backup power supply battery maintains the correct time of day during shipping If the freezer stays in the Central Time Zone the time of day does not need to be reset If the freezer is installed in a different time zone the time clock can be reset to the correct time of day if desired Refer to Setting the Time Clock to the Current Time of Day page 8 PROGRAMMING THE ELECTRONIC DEFROST TIMER Use a small probe such as a pen pencil or screwdriver to move the switches during programming Switches are OFF when the tab is left ON when tab is moved to the right Before programming if the initial switch settings are not all off Fig 12 make a record of the current switch settings on a plece of paper this Indicates the current defrost schedule Then slide all 24 Switches to the left or OFF position Fig 12 During programming all settings must be completed within 4 minutes or the timer will return to normal Operation Mode Once programming is done restore the previous def
8. and position the door face down ona workbench ortable Using au open end or adjustable wrench turn the hinge mechanism shaft 135 Fig 3 5 Replace the hinge plates and door s in the reverse order of disassembly Hf cabinets are too tall the refrigeration system may need to be removed in order to pass through short openings Contact your dealer or authorized servicer if this becomes necessary bee MOUNTING screw A C Br nm 1 mr POSITION 1 LEFT MAND HINGED DOOR POSITION 2 RIGHT HANO HINGED DOOR Fig Once the cabinet is in its final position replace any components that may have been removed door handle etc and then level the cabinet front to back and side to side by adjusting the legs as required Door Hinging Should the doors need to be rehinged from right to left or vice versa contact a Hobart authorized Refrigeration Service Company LEGS OR CASTERS WARNING THE CABINET MUST BE BLOCKED AND STABLE BEFORE INSTALLING LEGS OR CASTERS Legs Fig 5 Toinstallthe legs raise and block the reach in a minimum of 7 from the floor and thread the legs into the Threaded Holes on the bottom ofthe cabinet This unit must be level in order to operate properly Tum the adjustable feet in or out as required to level the unit front to back and side to side NOTE Three section front opening cabinets come with five legs the fifth leg should be placed in the front center threaded
9. cabinet Three section cabinets have two HUMIDITY control dials Fig 10 ELECTRONIC DEFROST TIMER when equipped mE H BA a g ti SET E le Hi MANUAL Hi SB STON Fig 12 It your freezer is equipped with an electronic Defrost Timer it is located in a control box behind the trim rail at the top of the Reach In Freezer To access the the Defrost Timer remove the Thumbscrew on the left side of the Control Box and slide the Lid to the left Fig 11 Save the Thumbscrew and Lid and put them back in place after programming is done The Defrost Timer s clock is operating from the backup power supply battery during shipping and before installation Once the freezer is plugged in the Defrost Timer operates off of the AC power supply the battery is only used during a power interruption or outage This battery is a permanent type that is not replaceable except by replacement of the defrost timer itself For additional information on behavior of the defrost timer if the battery loses power refer to page 11 When the AC power is plugged in the defrost time clock automatically switches the battery to a standby condition When the Freezer is connected to the AC electrical power supply the SET CLOCK light on the Defrost Timer Fig 12 blinks rapidly to indicate that the Defrost Timer is in normal Operation Mode
10. e the cabinet LOCATION For optimum performance the condensing unit of the reach in refrigeration models only must have an adequate supply of air for cooling purposes The operating location must provide either a minimum 12 clearance overhead of the condensing unit or the unrestricted flow of air at the back of the reach in ASSEMBLY Some components can be removedtoallowthe cabinet to pass through short or narrow doorways The door handle can be removed as follows 1 Remove the screw and bolt from the tumbler 2 Removethe two mounting screws and the handle assembly Fig 1 8 Replace in reverse order of disassembly Door s and hinges can be removed as follows 1 Lift up and remove the front trim panel Fig 1 2 Remove the screws which secure the trim rail cover Fig 1 unplug the door switch lead wires and remove the screws which secure the trim rail Fig 1 Carefully lay the trim rail on top of the cabinet avoid damaging or kinking the thermometer capillary tube 3 Remove the three screws which secure the upper hinge plate to the cabinet Fig 2 This will remove hinge tension Remove the nut underneath the lower hinge plate which secures the bottom hinge Remove door Remove lower hinge plate Fig 2 4 If the hinge mechanism should become uncocked while changing the door it will be necessary to recock the hinge mechanism To do this remove the door from the cabinet
11. efrost cycle to begin on the half hour slide the two adjacent switches to the right For example to start a defrost cycle at 2 30 pu slide switches 2 and 3 to the right in the lower set of switches Custom Defrost Schedule Example 1 Fig 16 shows five defrost cycles that begin at 1 am 6 am 10 Au 2 30 pm and 8 Pm Custom Defrost Schedule Example 2 Fig 17 shows six defrost cycles that begin at 1 am 4 am 10 Au 2 30 pm 6 pm and 9 30 pw During normal operation leave these switches set on the desired defrost schedule if itis other than the factory preset schedule Au Swirenes OFF Gives YouThe Custou Dernost Scheouue Exaunce 1 00 Au 6 00 au 10 00 au 2 30 Pu SE pre nmm aa T 5 Em FH es EP i t m K E ig EH S El Dis H z3 His E i5 E nii 25 Emi H zs M pz wc pr pz i EH NH Ed ad EH zB H eis 3 a 8 soon FAS Hes Hie ous I mod EIS 2 x HE emote cw Hn Eye wr fie we wo pr DEFROST ON bEFROSTON gt nin n Program Review During normal Operation Mode with the SET CLOCK light blinking rapidly Blink HH 4 Blinks times 5 MM V EE A
12. he left or OFF position In the lower set of switches move the one switch to the right that corresponds to the desired Defrost Duration nearest 5 minutes The example Fig 14 sets the Defrost Duration at 30 minutes Press and hold the SET button until the DEFROST ON light starts blinking Release the SET button and the SET CLOCK light flashes rapidly indicating that the timer has returned to normal Operation Mode To verify that the clock and the defrost duration are set properly perform Program Review page 10 Ea H gt Eg up BE us mme M H1 E IH B H tali he How to Set a Custom Defrost Schedule Begin with the defrost timer on normal Operation Mode The SET CLOCK light is blinking rapidly and the PROGRAM and DEFROST ON lights are off If all switches are OFF Fig 15 the factory preset defrost schedule is enabled 2 am 8 au 2 ru 8 eu Determine your own best defrost schedule The upper set of switches represents the AM hours the lower switches represent the PM hours Allow a minimum of 2 hours between the start of any two defrost cycles To customize your defrost schedule begin with all switches OFF Fig 15 the SET CLOCK light blinking rapidly as in normal Operation Mode slide the switches to the Tight that correspond to the hour when each defrost cycle should begin If you want a d
13. hes in the lower set remain OFF Ifthe time is 0 to 3 minutes after the hour all 11 switches can remain OFF The last switch of the lower set of switches selects AM or PM Leave the tab on the left for AM Slide the tab to the right for PM The example Fig 13 sets the Time Clock at 2 45 pu Pine E E EH His B Eg B E Hl xr Ems B H EB EB Hi a mi zd mE Cm 115 DEFROST ON Fig 13 Press and hold the SET button until the SET CLOCK light starts blinking Release the SET button the SET CLOCK light goes off and the DEFROST ON light begins to blink and then remains on Continue with Setting the Defrost Duration To exit without setting the Defrost Duration return all switches to the left press the PROGRAM button for three seconds and release the PROGRAM button normal Operation Mode returns with the SET CLOCK light blinking rapidly Setting the Defrost Duration The Defrost Duration was preset atthe factory for 25 minutes Depending onfreezerusage and your defrost schedule you may choose to customize the Defrost Duration The usual and recommended Defrost Duration setting is 25 minutes Complete either the section titled To Change the Defrost Duration and Bypass the Setting of the Time Clock or complete the section titled Setting the Time Clock to the Current Time of Day before continuing With the PROGRAM and the DEFROST ON lights lit Move all 24 switches to t
14. hole In the case of a three section pass through cabinet a sixth leg is included for the rear center hole Failure to install these legs in the proper location may result in damage to the cabinet Casters Fig 6 Use casters only on reach in models with self contained refrigeration systems that have cord and plug electrical connections Raise and blockthe cabinet a minimum of 7 from the floor Thread the casters into the holes in the bottom of the cabinet Fig 2 Casters with brake should be installed at the front Securely tighten the caster with the octagon shaped Bolt head underneath not the round flange on top Shelves Fig 7 If purchased the shelves and shelf clips are shipped with the cabinet Insert the shelf clips into the pilaster and install the shelves Index holes are provided in the pilaster to help in leveling the shelves Bonus shelves are provided to fill the space between the shelves These are positioned and supported by the shelves NOTE Loosen all thumbscrews which secure shelf pilasters and light cover s prior to placing product in cabinet Thumbscrews should be loose enough to remove with your fingers so parts can be readily removed for cleaning without the use of tools Failure to comply with this request will invalidate the NSF listing Utility Base Optional If your unit comes with a utility base we recommend securing the base to the floor to prevent damage tothe floor outlet due to
15. ing the control knob in Pl the direction of the arrow lowers the temperature The control 3 knob has a marked OFF position which interrupts power to the i compressor and condenser fan only not the entire reach in e NOTE Over under units have separate temperature controls for each refrigeration system They are located on the front of each evaporator housing STANDARD THERMOMETER Fig 9 The standard digital thermometer is calibrated at the factory and does not pe recalibration OPTIONAL DIAL THERMOMETER The optional dial thermometer can be recalibrated Compare the cabinet thermometer with an accurate test thermometer If there is any variation contact a Hobart authorized Refrigeration Service Company mus ER CONTROLS Safe T Thaw Only The optional Safe T Thaw adaptation of the two or three section reach in refrigerators significantly reduces the defrost time of all frozen foods under a controlled environment without employing temperatures over 45 F Safe T Thawincorporates a two stage thermostat a reversing valve on the refrigerantline and multiple fan units for increased internal air circulation When non frozen food is placed in the Safe T Thaw unit itoperates as a normal refrigerator the thermostat switches cooling on at 40 F and off at 36 F When sufficient load of frozen foodis placedin the cabinetto lower the temperature to 33 F the heating mode is activated The two stage thermostat will
16. molive green or Ivory Never allow gaskets to contact concentrated cleaners or disinfectants This can cause premature failure of the gasket material Condenser Coil WARNING DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING THE CONDENSING UNIT Check the condenser coil weekly This surface must be kept free of dirt and grease for proper system operation Remove the front trim panel and carefully vacuum or brush dirt and lint from the condenser coil Replace the trim panel Evaporator Coil Drain Pan Condensate Loop and Condensate Dish When needed flush these components with fresh water This should be a part of any routine maintenance program and can prolong the life of the equipment Light Bulb Replacement when equipped Replace light bulb s with 40 watt incandescent appliance type bulb s ONLY The protective cover can easily be removed and replaced Florescent Light Bulb Replacement when equipped Remove protective cover Replace florescent tube with same size and type 40 watt 48 long TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE Unit fails to operate Power failure Plug loose in receptacle Blown fuse or tripped circuit breaker ifa freezer model is in a deftost cycle wait 30 minutes and recheck Check the Temperature Control page 5 or 6 to make sure it is not OFF If the suggestions above fail to remedy the situation contact service WARRANTY The Q series cabinet warranty is fortwo years It includes part
17. on Freezers or on Convertible Models with Freezer Chambers when power is initially applied to the cabinet the exterior dial of the defrost time clock must be set to the correct time of day To access the defrost timer remove the front trim panel Fig 2 by lifting up and out Open zwecrowrowtm exTenion DIAL 24 HOU door on the defrost timer box Turn the inside knob counterclockwise until the exterior dial is positioned so the correct time of day is at the time of day pointer Replace the front trim panel when done The defrost timer Fig 19 is set at the factory tor four 26 minute defrost cycles per day 2 am 8 am 2 rm and 8 pu Depending on local conditions it may be necessary to change the frequency or duration of defrost cycles If the power supply is interrupted the defrost timer must be reset to the correct time of day END DEFROST BEGIN DEFROST es MINUTES Fig 19 cH MAINTENANCE CLEANING Cabinet Clean the inside of the cabinet and the doors weekly with a warm water solution of mild household liquid dishwashing detergent such as Palmolive green or Ivory Do not use anything containing grt abrasive materials bleach or harsh chemicals Be cautious with new or improved formulas use only after being well tested Rinse thoroughly and dry with a clean soft cloth Gaskets Door gaskets should be cleaned weekly using a warm water solution of mild household liquid dishwashing detergent such as Pal
18. position of the switches dictates the defrost schedule If all switches are OFF the factory preset times of 2 AM 8 AM 2 PM and 8 PM will initiate deftost cycles 2 8 14 and 20 hours after power was restored The factory preset defrost duration of 25 minutes is re invoked Because the clock resumed at 12 00 midnight it must be reset to the current time of day to avoid inconvenient defrost cycles Refer to Setting the Time Clock to the Current Time of Day page 8 If the Defrost Duration was set at a value other than the factory preset 25 minutes reset it If power is lost again reset again Refer to Setting the Defrost Duration page 8 It you are using a custom Defrost Schedule the switches must be reset after resetting the time and Defrost Duration Any defrost start times that are set by the positions of the program switches will override the factory preset defrost start times even if the battery is weakened If the battery has weakened and reprogramming the time of day defrost duration and schedule after a power interruption is too inconvenient the Electronic Defrost Timer can be replaced In the event of a power surge or lightning the SET CLOCK PROGRAM and DEFROST ON lights will all blink the same as for a weak battery but the battery may not have weakened First try to reprogram the Defrost Timer If the Defrost Timer fails to function normally contact service MECHANICAL DEFROST TIMER Fig 19 When equipped
19. rost schedule by returning the switches to the same positions noted on your record To Change the Defrost Duration and Bypass the Setting of the Time Clock Begin with the SET CLOCK light ig rapidly icating normal Operation Mode Ifyou wantto change the Defrost Duration but not reset the time of day press and hold the PROGRAM button for about 3 seconds until the PROGRAM light starts blinking Release the PROGRAM button and the PROGRAM light and the SET CLOCK light remain lit Press and hold the PROGRAM button again until the DEFROST ON light starts blinking Release the PROGRAM button and the DEFROST ON light remains lit Skip the section titled Setting the Time Clock to the Current Time of Day below and continue with Setting the Defrost Duration bottom of this page Setting the Time Clock to the Current Time of Day Begin with the SET CLOCK light blinking rapidly indicating normal Operation Mode Begin with all switches OFF Fig 12 Press and hold the PROGRAM button for about 3 seconds until the PROGRAM light starts blinking Release the PROGRAM button and the PROGRAM and the SET CLOCK lights remain lit The upper set of switches sets the HOUR Slide the switch that corresponds to the current hour to the right The 11 other switches remain OFF The lower set of switches sets the MINUTES Find the switch that is within 5 minutes of the current minutes and move it to the right At least 10 of the other switc
20. s labor and travel during normal working hours in the continental United States The non prorated compressor warranty is for an additional three years and does not include labor For additional information or to discuss a maintenance program contact your local authorized refrigeration servicer FORM 14500 Rev L Jan 2002 eme PRINTED IN USA
Download Pdf Manuals
Related Search
Related Contents
Sun Fire X2250 Server Installation Guide Focus Electrics 53783 electrical kettle Trust 19173 Protection contre les produits chimiques et les liquides • Avec e-Suitability User Manual - Avail eSuitability Whitehaus Collection WH920ASL-SASS Installation Guide Inscription aux épreuves de sélection 2015 Raumtemperatur-Regler mit Wochenprogramm Room Thermostat Media-Tech U-drive DVR Copyright © All rights reserved.