Home

Hobart ADVANSYS CL64ER User's Manual

image

Contents

1. D 941478 REV B 19 9 16 29 7 16 11 F fe 29 3 16 8 5 16 28 7 16 511 16 3 BOOSTER I 3 1 2 EXHAUST pe IN s mmm L PM 4 X 16 px p 5 8 X 12 1 16 E NEN ul E 11 1 2 CHEMICAL PORTS 3 3 4 4 N L 40 1 2 ME CO ee at FLOOR SINK DOOR N BY OTHERS CLEARANCE N hom MIN 1 20 SERVICE CLEARANCE BOTH SIDES PLUMBING NOTES ELECTRIC STEAM AND GAS HEATS SINGLE POINT ELECTRICAL CONNECTION 3 PH ONLY MOTORS AND ELECTRIC TANK HEAT MINIMUM WATER HAMMER ARRESTOR MEETING ASSE 1010 STANDARD Raren SUPPLY MAXIMUM MISCELLANEOUS NOTES R EQUIVALENT TO BE SUPPLIED BY OTHERS IN VOLTAGE CIRCUIT PROTECTIVE HOT AND COLD WATER SUPPLY LINES AT SERVICE CONNECTIONS AMPS CONDUCTOR DEVICE OPTIONAL VENT HOOD OR EXTENDED HOOD EXHAUST RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS AMPACITY REQUIREMENTS 200 CFM ENTRANCE END FOR BEST RESULTS ALL DIMENSIONS TAKEN FROM FLOOR LINE MAY BE RECOMMENDED BUILDING FLOWING HOT AND COLD WATER PRESSURE 208 60 3 91 5 125 125 INCREASED APPROXIMATELY 3 4 OR DECREASED 1 2 TO
2. 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com SPECIFICATIONS Meets requirements of A S S E Standard No 1004 DESIGN Semi automatic high temperature double tank rack type dishwasher with flexible thermal layer curtains at the ends of chamber and between wash rinse and final rinse zones Insulated hinged inspection doors located in front of machine provide easy access to wash arms rinse arms strainer strainer basket and pump intake screen Length of machine inside tank at table connection 64 Machine designed to clean and sanitize with hot water 160 F wash 160 power rinse and 180 F minimum final rinse Water hardness recom mended to be 3 gr for best results Automatic interlocks shut off pump and conveyor if door is opened when machine is in operation CONSTRUCTION Tank chamber frame legs control box doors and all panels are constructed of stainless steel PUMP Two 165 gpm recirculating stainless steel pumps and impeller with a ceramic seat seal Easily accessible pumps assembly permits quick inspection The pumps are self drain ing All piping distributing water to the upper and lower wash arms is stainless steel tubing PUMP MOTOR Built for Hobart 2 hp grease packed ball bear ings splash proof ventilated with manual resettable inherent overload protection Available in electrical specifications of 208 240 60 3 480 60 3 and 600 60 3 Also available but not submitted for UL
3. GAS HEAT ONLY FOR NATURAL GAS PRESSURE TO THE BURNER CUSTOMER MOTORS 1 6 HP CONVEYOR CONNECTION SHOULD BE 3 5 MIN 7 MAX W C 2 HP WASH FOR LP GAS PRESSURE TO THE BURNER CUSTOMER MINIMUM CONNECTION SHOULD BE 8 MIN 11 W C RATED SUPPLY MAXIMUM IF GAS PRESSURE IS HIGHER THAN 7 NAT OR 11 LP W C VOLTAGE AMPS CIRCUIT PROTECTIVE A PRESSURE REGULATING VALVE MUST BE INSTALLED CONDUCTOR DEVICE BY OTHERS IN THE GAS LINE TO THE DISHWASHER GAS HEAT NATURAL OR LP BTU HR INPUT 78 000 208 240 60 3 19 4 25 25 GAS EXHAUST VENTING MUST BE INSTALLED ACCORDING TO LOCAL CODE DO NOT CONNECT FLUE TO POWER VENT 380 60 3 12 8 20 20 SEE INSTALLATION MANUAL FOR GAS VENTING 480 60 3 10 8 15 15 600 60 3 9 5 15 15 Page 8 of 12 F 40293 CL6a4eR advansys Dishwasher 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com CL64eR advans s GAS R L 29716 293 16 k 287 16 28 1 8 L 20 1 16 11 17 1 8 6 9 16 3u 11 1 2 BOOSTER CHEMICAL aa HW l LH4I 4 PORTS d EXHAUST 4 X 16 See Q m SERE 1 F 12 1 16 4 10 1 2 e 5 1 2 23 FLOOR SINK OPEN DOOR BY OTHERS CLEARANCE 20 SERVICE CLEARANCE BOTH SIDES PLUMBING
4. E2 ELECTRIC CONNECTION BOOSTER 30KW CONNECTIONS MAY BE DRAINED TO EITHER SIDE 1 1 4 CONDUIT HOLE OR 2 CONDUIT HOLE j 63 3 4 AFF P4 FEEDER REMOVE 1 8 NPT PIPE PLUG TO ACCESS TAPPED HOLE 1 8 NPT 59 9 16 AFF E3 ELECTRIC CONNECTION DETERGENT AND RINSE FEEDERS 1 2 CONDUIT 64 1 4 AFF P5 DETERGENT PROBE SENSOR REMOVE CAP AND STUD ASSEMBLY TO ACCESS 7 8 DIA HOLE WASH TANK ONLY 14 5 8 AFF ELECTRIC HEAT ONLY P6 INDIRECT DRAIN FLOOR SINK BY OTHERS 0 AFF WHEN REQUIRED INSTALL FLOOR SINK OUTSIDE SINGLE PHASE OR FIELD CONFIGURED THE PERIMETER OF THE DISHWASHER 3 PHASE SEPARATE ELECTRIC CONNECTION P13 HOT WATER CONNECTION 1 2 11 3 16 AFF E4 ELECTRIC CONNECTION MOTORS AND CONTROLS pia MTS ER EL x 1 1 4 CONDUIT 63 3 4 AFF COLD TEMP EE EMIN E5 ELECTRIC HEAT 15 000 WATTS WASH TANK 1 CONDUIT HOLE 63 3 4 AFF E6 ELECTRIC HEAT 10 000 WATTS RINSE TANK 1 CONDUIT HOLE 63 3 4 AFF F 40293 CL64eR advansys Dishwasher Page 7 of 12 CL64eR advansys GAS L R 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com 19 9 16 4 29716 11 lt lt 293 16 4 5 11 16 28 7 16 3 11 1 4 BOOSTER EXHAUST 4 X 16 614 A 5 8 5 1 2 Ty mine i y E 11 1 2
5. not to exceed 11 W C If gas pressure is higher than 7 W C natural or 11 W C LP pres sure regulating valve must be supplied by others in the gas line to the dishwasher OPTIONAL EQUIPMENT AT EXTRA COST Stainless steel vent hoods with vent stack and locking type damper load end only Canopy exhaust power vent kit Higher than standard chamber Side loaders and unloaders 19 x 19 peg combination and miscellaneous racks Table limit switch Drain water tempering kit As continued product improvement is a policy of Hobart specifications are subject to change without notice Page 12 of 12 F 40293 REV 03 11 F 40293 CL64eR advansys Dishwasher LITHO IN U S A H 01 Printed On Recycled Paper
6. CONNECTIONS CONNECTION INFORMATION AFF AB0VE FINISHED FL00R LEGEND ELECTRIC STEAM AND GAS HEATS ELECTRICAL CONNECTIONS P2 DRAIN 2 FPT 7 3 8 AFF TWO POSSIBLE CONNECTIONS MAY BE DRAINED TO EITHER SIDE AERE R OF VALVE PLUG OPPOSITE SIDE P4 FEEDER REMOVE 1 8 NPT PIPE PLUG TO LEGEND ACCESS TAPPED HOLE 1 8 NPT 59 9 16 AFF P5 DETERGENT PROBE SENSOR REMOVE CAP AND STUD ASSEMBLY TO ACCESS 7 8 DIA HOLE ELECTRIC STEAM AND GAS HEATS WASH TANK ONLY 14 5 8 AFF Et ELECTRIC CONNECTION SINGLE POINT ELEC GAS PO INDIRECT tte aren SIN BY OTHERS 0 ARF er En WHEN REQUIRED INSTALL FLOOR SINK OUTSIDE A 8 CONDUIT HOLE OR 2 CONDUIT THE PERIMETER OF THE DISHWASHER P13 HOT WATER CONNECTION 1 2 11 3 16 AFF E2 ELECTRIC CONNECTION BOOSTER 30KW 1 1 4 CONDUIT HOLE OR 2 CONDUIT HOLE HIGH FEMP WIS0KBO0DSTER 110 F MIN 63 3 4 AFF P14 COLD WATER CONNECTION 1 2 FPT 14 3 8 AFF ELECTRIC CONNECTION DETERGENT AND RINSE FEEDERS 1 2 CONDUIT 64 1 4 AFF GAS HEAT ONLY P9 GAS CONNECTION NAT 3 4 FPT 8 1 4 AFF 3 5 MIN 7 MAX W C INCOMING P10 GAS CONNECTION L P 3 A FPT 8 1 4 AFF 8 MIN 11 MAX W C INCOMING F 40293 CL64eR advans s Dishwasher Page 9 of 12 CL64eR advansys STEAM L R 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com 29 7 16 29 3 16 28 7 16 12 gt 19 9 16 11 8 1 2
7. Dirty water indicator Delime notification Conveyor dwell Energy Saver Mode NAFEM Data Protocol compliant Pressure regulating valve Booster heater 30 kw WASH TANK HEATING SELECTIONS must choose one ELECTRIC Two electric Incoloy sheathed immersion heaters 15 KW and 10 KW removable from inside tank Tank water temperature is controlled by microprocessor controlled thermostat with positive low water protection and magnetic contactor Disconnect switches not furnished A high limit device mounted on the surface of the tank additionally protects heating element STEAM One inch stainless steel steam coil Tank water temperature controlled by microprocessor controlled thermostat with positive low water protection Steam supplied to machine through high temperature steam solenoid valve and line strainer GAS Regulated infrared immersion tube gas burner system Microprocessor controlled thermostat and a blower with a pressure switch control tank water temperature Positive low water protection is provided A high limit device mounted on the surface of the tube additionally protects immersion tube A solid state igniter board controls the gas valve and provides flame ignition A transformer steps the control circuit voltage down from 120 volts to 24 volts to power the igniter board and gas valve For natural gas gas pressure to burner customer connection not to exceed 7 W C For LP gas gas pressure to burner customer connection
8. T CHEMICAL PORTS 5 3 3 4 3 10 1 2 DOOS 23 FLOOR SINK OPEN DOOR BY OTHERS CLEARANCE gt L b MIN EEEE TESTE 20 SERVICE CLEARANCE BOTH SIDES MISCELLANEOUS NOTES OPTIONAL VENT HOOD OR EXTENDED HOOD EXHAUST REQUIREMENTS 200 CFM ENTRANCE END ALL DIMENSIONS TAKEN FROM FLOOR LINE MAY BE INCREASED APPROXIMATELY 3 4 OR DECREASED 1 2 64 INSIDE TANK AT TABLE CONNECTION 63 25 32 TABLE TO TABLE NET WEIGHT OF MACHINE 794 LBS STD HEIGHT DOMESTIC SHIPPING WEIGHT 970 LBS STD HEIGHT REQUIRES A BACKDRAFT DAMPER IN THE VENTILATION SYSTEM TO BE SUPPLIED AND INSTALLED BY OTHERS SERVICE CONNECTION FOR MOTORS AND CONTROLS PLUMBING NOTES ELECTRIC STEAM AND GAS HEATS WATER HAMMER ARRESTOR MEETING ASSE 1010 STANDARD OR EQUIVALENT TO BE SUPPLIED BY OTHERS IN HOT AND COLD WATER SUPPLY LINES AT SERVICE CONNECTIONS RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS FOR BEST RESULTS RECOMMENDED BUILDING FLOWING HOT AND COLD WATER PRESSURE TO THE DISHWASHER IS 20 PSI 15 PSI MIN 25 PSI MAX IF COLD WATER TEMPERATURE IS LESS THAN 55 F CONTACT SALES ENGINEERING FOR CONVENIENCE WHEN CLEANING WATER TAP SHOULD BE INSTALLED NEAR MACHINE WITH HEAVY DUTY HOSE AND SQUEEZE VALVE WHEN USED CHEMICAL SANITIZING FEEDER MUST BE CERTIFIED TO NSF STANDARD 29
9. THE DISHWASHER IS 20 PSI 15 PSI MIN 25 PSI MAX 240 60 3 904 125 125 64 INSIDE TANK AT TABLE CONNECTION IF COLD WATER TEMPERATURE IS LESS THAN 55 F CONTACT 63 25 32 TABLE TO TABLE SALES ENGINEERING 480 60 3 45 3 60 60 NET WEIGHT OF MACHINE 794 LBS STD HEIGHT FOR CONVENIENCE WHEN CLEANING WATER TAP SHOULD BE 200 50 3 89 7 125 125 DOMESTIC SHIPPING WEIGHT 970 LBS STD HEIGHT INSTALLED NEAR MACHINE WITH HEAVY DUTY HOSE AND REQUIRES A BACKDRAFT DAMPER IN THE VENTILATION SQUEEZE VALVE 380 60 3 49 2 60 60 WHEN USED CHEMIC SYSTEM TO BE SUPPLIED AND INSTALLED BY OTHERS WHEN USED CHEMICAL SANITIZING FEEDER MUST BE CERTIFIED 380 515 50 3 520 600 60 3 32 5 45 45 SEPARATE SERVICE CONNECTION SEPARATE SERVICE SEPARATE SERVICE FOR MOTORS ON ELEC HEAT CONNECTION FOR ELEC HEAT CONNECTION FOR ELEC HEAT MOTORS 1 6 HP CONVEYOR ELEC HEAT 15 KW WASH ELEC HEAT 10 KW RINSE MINIMUM MINIMUM MINIMUM RATED SUPPLY MAXIMUM SUPPLY MAXIMUM RATED SUPPLY MAXIMUM VOLTAGE AMPS CIRCUIT PROTECTIVE VOLTAGE CIRCUIT PROTECTIVE VOLTAGE AMPS CIRCUIT PROTECTIVE CONDUCTOR DEVICE CONDUCTOR DEVICE CONDUCTOR DEVICE AMPACITY AMPACITY 208 60 3 16 5 20 20 208 60 3 60 60 208 60 3 30 40 40 240 60 3 15 9 20 20 240 60 3 60 60 240 60 3 28 6 40 40 480 60 3 9 5 15 15 480 60 3 22 30 30 480 60 3 14 3 20 20 200 50 3 17 5 25 25 200 50 3 43 60 60 200 50 3 28 9 40 40 380 60 3 112 15 15 380 60 3 23 30 30 380 60 3 15 2 20 20 380 415 50 3 10 6 15 15 380 415 50
10. able perforated stainless steel strainer pan supports a deep perforated stainless steel basket FINAL RINSE Final rinse flow rate 2 2 gpm 39 gpr 132 gph Stainless steel upper and lower Auto Position Rinse Arms have single rows of nozzles Racks entering the rinse zone automatically trigger rinse Final rinse water line is equipped with a vacuum breaker downstream of an electrically operated solenoid valve in common piping system Rinse agent dispenser injection ports provided in final rinse piping above chamber FILL Fill water line is equipped with vacuum breaker on down Stream side of electrically operated solenoid valve in common piping system for automatic maintenance of tank level DRAIN AND OVERFLOW Large bell type automatic overflow and drain valve controlled from inside of machine Drain automatically seats by closing inspection doors Drain housing can be plumbed from load or unload end of machine STANDARD EQUIPMENT Energy Recovery Digital display of wash and final rinse temperature Positive low water pro tection for tank heat Thermal Layered Curtains throughout machine are keyed to ensure proper placement Drain is auto matically closed when inspection doors are closed Stainless steel adjustable feet Bolted stainless steel enclosure panels around perimeter and underneath machine Automatic tank fill Door interlock Auto timer Vent fan and booster heater con trols Low temperature alerts Service diagnostics
11. listing are 200 240 50 3 and 380 415 50 3 ENERGY RECOVERY COIL The condensing system using a tube and fin coil constructed of copper and corrosion resistant aluminum CONTROLS A stainless steel control module with power and start stop buttons is mounted on top of the machine Machine control circuitry will be operated from a 120 volt control circuit transformer Electrical components are completely wired with 105 C 600V thermoplastic insulated wire with stranded conductors routed through UL listed electrical conduit or covered wire way CONVEYOR Rapid Return drive designed for more even throughput of racks and allows for an 18 75 inch separation between the wash and the rinse zone Racks conveyed automatically through wash and rinse zones Ball Detent Clutch drive prevents damage to machine or racks should movement of racks be obstructed Conveyor speed 9 5 FPM DRIVE MOTOR Built for Hobart horsepower gear motor ventilated with manual resettable inherent overload protection Available in electrical specifications of 208 240 60 3 480 60 3 and 600 60 3 Also available but not submitted for UL Listing are 200 240 50 3 and 380 415 50 3 POWER WASH AND RINSE Wash and rinse tanks are equipped with upper and lower stainless steel CFD Wash Arms which effectively direct water jets to all ware surfaces Both upper and lower wash arms are self aligning and have easily removable end caps for cleaning without use of tools A remov
12. 3 29 40 40 380 415 50 3 16 6 25 25 600 60 3 8 5 15 15 600 60 3 144 20 20 600 60 3 9 6 15 15 Page 6 of 12 F 40293 CL6a4eR advansys Dishwasher CL64eR advans s 701 S Ridge Avenue Troy OH 45374 ELECTRIC R L 1 888 4HOBART www hobartcorp com MODEL CL64eR PN R L OPERATION I 293 16 4 D 941477 REV B F 287 16 28 1 8 20 1 16 1t 17 1 8 8 5 16 gt 6 9 16 5 11 16 ai 3 1 2 11 1 2 Booster CHEMICAL m diese osx EL a e e ad EXHAUST 4 X 16 PORTS oie 1 i eS 10 1 2 5 8 121 16 P o 3 3 4 E 9 P4 p13 E1 E5 23 FLOOR SINK OPEN DOOR BY OTHERS CLEARANCE 12 NN MIN 1 ote u tal a Say ee el apu Tang a ee S s ie ey ek ae l 20 SERVICE CLEARANCE BOTH SIDES ELECTRICAL CONNECTIONS CONNECTION INFORMATION PLUMBING CONNECTIONS AFF AB0VE FINISHED FL00R CONNECTION INFORMATION LEGEND AFF AB0VE FINISHED FL00R ELECTRIC STEAM AND GAS HEATS LEGEND E1 ELECTRIC CONNECTION SINGLE POINT ELEC GAS ELECTRIC STEAM AND GAS HEATS amp STEAM 1 1 4 CONDUIT HOLE OR 2 CONDUIT 63 3 4 AFF P2 DRAIN 2 FPT 7 3 8 AFF TWO POSSIBLE
13. 5 11 16 lt BOOSTER EXHAUST 09 4 X 16 11 13 16 BOTH SIDES MISCELLANEOUS NOTES OPTIONAL VENT HOOD OR EXTENDED HOOD EXHAUST REQUIREMENTS 200 CFM ENTRANCE END ALL DIMENSIONS TAKEN FROM FLOOR LINE MAY BE INCREASED APPROXIMATELY 3 4 OR DECREASED 1 2 64 INSIDE TANK AT TABLE CONNECTION 63 25 32 TABLE TO TABLE NET WEIGHT OF MACHINE 794 LBS STD HEIGHT DOMESTIC SHIPPING WEIGHT 970 LBS STD HEIGHT REQUIRES A BACKDRAFT DAMPER IN THE VENTILATION SYSTEM TO BE SUPPLIED AND INSTALLED BY OTHERS SERVICE CONNECTION FOR MOTORS AND CONTROLS MOTORS 1 6 HP CONVEYOR 2 HP WASH MINIMUM RATED SUPPLY MAXIMUM VOLTAGE AMPS CIRCUIT PROTECTIVE CONDUCTOR DEVICE AMPACITY 200 240 50 3 17 5 25 25 208 240 60 3 19 4 25 25 380 415 50 3 10 6 15 15 380 60 3 12 8 20 20 480 60 3 10 8 15 15 600 60 3 9 5 15 15 Page 10 of 12 51 2 8 1 2 p Lx 5 L 121 16 NE 11 1 2 10 CHEMICAL PORTS 3 3 4 L 10 1 2 23 FLOOR SINK OPEN DOOR BY OTHERS CLEARANCE 20 SERVICE CLEARANCE PLUMBING NOTES ELECTRIC STEAM AND GAS HEATS WATER HAMMER ARRESTOR MEETING ASSE 1010 STANDARD OR EQUIVALENT TO BE SUPPLIED BY OTHERS IN HOT AND COLD WATER SUPPLY LINES AT SERVICE CONNECTIONS RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS FOR BEST RESULTS
14. 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com STANDARD FEATURES Energy recovery 342 racks per hour Opti RinSe system 30 KW electric booster heater Rapid return conveyor drive mechanism E Insulated hinged double doors with door interlock switches Door seal system Pressure regulating valves 19 5 inch chamber height opening Top mounted micro processer control module Energy saver mode Dirty water indicator Bi Low temperature alert Conveyor dwell Delime notification Service diagnostics NAFEM Data Protocol compliant Computational fluid dynamic designed self aligning wash manifolds Stainless steel debossed anti clogging wash arms Removable integrated pump intake screen Stainless steel self draining pump and impeller Single sloping scrap screen and deep basket Stainless panels enclose perimeter and bottom Door actuated drain closure Single point electrical connection does not include the booster heater DIRECTION OF OPERATION Right to Left Left to Right VOLTAGE 208 60 3 240 60 3 380 60 3 C 480 60 3 C 600 60 3 Item Quantity C S lI Section 11400 CL64eR advansijs DISHWASHER MODEL Q CL64eR Dishwasher OPTIONS AT EXTRA COST Single point electrical connection to include electric booster three phase only Higher than standard chamber
15. ACCESSORIES Q Stainless steel vent hoods load end only Canopy exhaust power vent kit Direct drive unloader Q Side loader Blower dryer Drain water tempering kit Specifications Details and Dimensions on Inside and Back 9 NSP ENERGY STAR F 40293 CL64eR advansys Dishwasher Page 1 of 12 O aa A iss JJ Cy gt Ti C g gt m JJ CL64eR advans s DISHWASHER 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com THE CLeR WAREWASHER IS STANDARD WITH THESE EFFICIENT FEATURES Inside and out the CLeR warewashers by Hobart are packed with standard components and design innovations that make them the biggest value in the dishwasher industry The insulated hinged inspection doors provide easy access in the chamber Exterior wash pipes and reduced interior baffles reduce clean up time The Rapid Return drive allows for a wide separation between the wash and the rinse zone The Hobart exclusive microprocessor control module offers a choice of many features such as an exclusive Energy Saver Mode Low Temperature Alerts and Dirty Water Indicator It also displays pertinent machine status and has a Delime Notification The controls have built in Service Diagnostics and are NAFEM Data Protocol Compliant Wash Manifolds Computational Fluid Dynamic designed wash manifolds are self aligning and come with Hobart s signa
16. ATION AFF ABOVE FINISHED FLOOR LEGEND ELECTRIC STEAM AND GAS HEATS ELECTRIC CONNECTION SINGLE POINT ELEC GAS amp STEAM 1 1 4 CONDUIT HOLE OR 2 CONDUIT 63 3 4 AFF ELECTRIC CONNECTION BOOSTER 30KW 1 1 4 CONDUIT HOLE OR 2 CONDUIT HOLE 63 3 4 AFF ELECTRIC CONNECTION DETERGENT AND RINSE FEEDERS 1 2 CONDUIT 64 1 4 AFF F 40293 CL64eR advansys Dishwasher PLUMBING CONNECTIONS CONNECTION INFORMATION AFF ABOVE FINISHED FLOOR LEGEND ELECTRIC STEAM AND GAS HEATS DRAIN 2 FPT 7 3 8 AFF TWO POSSIBLE CONNECTIONS MAY BE DRAINED TO EITHER SIDE OF VALVE PLUG OPPOSITE SIDE RINSE FEEDER REMOVE 1 8 NPT PIPE PLUG TO ACCESS TAPPED HOLE 1 8 NPT 59 9 16 AFF DETERGENT PROBE SENSOR REMOVE CAP AND STUD ASSEMBLY TO ACCESS 7 8 DIA HOLE WASH TANK ONLY 14 5 8 AFF INDIRECT DRAIN FLOOR SINK BY OTHERS O AFF WHEN REQUIRED INSTALL FLOOR SINK OUTSIDE THE PERIMETER OF THE DISHWASHER HOT WATER CONNECTION 1 2 FPT 11 3 16 AFF HIGH TEMP W 30K BOOSTER 110 F MIN COLD WATER CONNECTION 1 2 FPT 14 3 8 AFF COLD TEMP 55 F MIN STEAM HEAT ONLY STEAM COILS 10 TO 50 PSI FLOWING 1 FPT 8 3 8 AFF CONDENSATE RETURN A 10 PSI MINIMUM DIFFERENTIAL PRESSURE ACROSS THE STEAM TRAP MUST BE MAINTAINED 3 4 FPT 11 1 8 AFF TWO CONNECTIONS TWO BUCKET TYPE TRAPS FURNISHED P2 P4 P5 P6 P13 P14 P7 P8 Page 11 of 12 CL64eR advansys DISHWASHER HOBART
17. Dishwasher CL64eR advans s 701 S Ridge Avenue Troy OH 45374 D S HWAS E R 1 888 4HOBART www hobartcorp com 13 k 63 1 2 10 363 4 363 4 OPTIONAL VENT 1 HOOD W DAMPER OPTIONAL EXTENDED VENT HOOD W DAMPER CE p 4 3 4 84 5 8 27421 i E 011 1 4 79 9 16 20 1 2 68 1 2 1 r po 65 9 16 l i l l 1 lt 1 R L OPER 34 1 8 7 8 2 2 1 p 1 l 4 Y Y Y Y MAY BE DRAINED TO EITHER SIDE OF VALVE PLUG OPPOSITE SIDE WIDTH OF 27 MACHINE 20 AVG INSIDE 27 WIDTH OF TABLE WIDTH TRACKS 14 1 2 H SUGGESTED TRACK AND TABLE LAYOUT FRONT MACHINE 6 2 HOLES FOR BOLTING TABLE TO TANK 114 8 AVG 3 8 mE TRACK HEIGHT 3 8 ABOVE TANK LIP 7 8 3 3 1A She USE SILICONE SEALER BETWEEN TABLE AND LIP OF TANK TO i eine ANK PREVENT LEAKAGE SECTIONAL VIEW SHOWING VIEW SHOWING HOLE LOCATIONS IN TABLE CONNECTIONS TURNED DOWN PORTION OF TABLE F 40293 CL64eR advansys Dishwasher Page 5 of 12 CL64eR advansys ELECTRIC L R 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com MODEL CL64eR L R OPERATION
18. RECOMMENDED BUILDING FLOWING HOT AND COLD WATER PRESSURE TO THE DISHWASHER IS 20 PSI 15 PSI MIN 25 PSI MAX IF COLD WATER TEMPERATURE IS LESS THAN 55 F CONTACT SALES ENGINEERING FOR CONVENIENCE WHEN CLEANING WATER TAP SHOULD BE INSTALLED NEAR MACHINE WITH HEAVY DUTY HOSE AND SQUEEZE VALVE WHEN USED CHEMICAL SANITIZING FEEDER MUST BE CERTIFIED TO NSF STANDARD 29 STEAM HEAT ONLY FLOWING STEAM PRESSURES ABOVE 50 PSI MUST HAVE A PRESSURE REGULATOR BY OTHERS INSTALLED IN THE STEAM LINE SHUT OFF VALVE MUST BE SUPPLIED BY OTHERS IN THE STEAM LINE TO THE DISHWASHER F 40293 CL6a4eR advansys Dishwasher 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com CL64eR advans s STEAM R L 29 7 16 293 16 I 287 16 25 3 4 l 28 1 8 20 1 16 11 17 1 8 3 3 4 6 9 16 3 1 2 1 1 8 11 1 2 BOOSTER EXHAUST 4 X 16 CHEMICAL PORTS s n F 12 1 16 Th 10 1 2 1 m I le 3 3 4 puo do 7 3 pL sk a i 9 Ec IN i 51 2 1 Cem eS em 23 N FLOOR SINK 1 1 OPEN DOOR 3 N Pr BY OTHERS CLEARANCE N t2 Lo Lo NE MIN 1 20 SERVICE CLEARANCE BOTH SIDES E1 E2 E3 ELECTRICAL CONNECTIONS CONNECTION INFORM
19. S 3 11 1 4 1 ris 79 9 16 1 1 l l 1 1 1 20 1 2 68 1 2 65 9 16 1 1 l 1 1 i L R OPER 34 1 1 1 l l ji 4 8 7 8 MAY DRAINED TO EITHER SIDE OF VALVE PLUG OPPOSITE SIDE 31 1 4 22 BOTH ENDS 15 5 8 1 5 16 OPTIONAL CANOPY EXHAUST POWER VENT WARNING ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND OR OTHER LOCAL ELECTRICAL CODES 15 16 19 11 16 zd CAUTION CERTAIN MATERIALS INCLUDING SILVER ALUMINUM AND PEWTER ARE ATTACKED BY SODIUM HYPOCHLORITE LIQUID BLEACH ATTN PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY SAFETY AND PLUMBING CODES BOOSTER HEAT 30 KW prona MAXIMUM EEC RATED QUT PROTECTIVE 58 1 2 Za FLUE FOR CONDUCTOR DEVICE GAS HEAT AMPACITY 200 240 50 3 80 2 90 90 VA 380 415 50 3 53 2 60 60 200 50 3 80 8 90 90 208 240 60 3 80 2 90 90 208 60 3 83 9 90 90 240 60 3 80 2 90 90 r WALL 380 60 3 42 5 60 60 ul 380 415 60 3 46 4 60 60 18 5 8 480 60 3 40 1 50 50 c 600 60 3 33 7 40 40 3 MIN FLUE CLEARANCE Page 4 of 12 F 40293 CL6a4eR advansys
20. equirements cally a feature that cuts space and reduces labor Cubic Feet per minute dramatically Your dishroom team will appreciate this End 200 feature Discharge End 175 Peak Rate of Drain Flow Gallons per minute OTHER AVAILABLE ACCESSORIES Initial rate with full tank 38 Blower dryer direct drive unloader Shipping Weight Crated Approximate Ibs 970 F 40293 CL64eR advans s Dishwasher Page 3 of 12 CL64eR Machine Ratings Mechanical Racks per hour 19 x 1924 342 Conveyor Speed feet per minute 9 5 max Dishes per Hour Average 25 per rack 8 550 Glasses per Hour Average 45 per rack 15 390 Floor Space Table to Table Inches 64 Overall Dimensions H x W x D Inches 7994 x 77 x 30 4 Motor H P Wash 2 Rinse 2 Conveyor Drive H P Number of Tanks 2 Tank Capacity Gallons Wash 23 Rinse 22 Pump Capacity Gallons per Minute Weir Test Combined 330 Heating Equipment For keeping power wash hot 156 000 BTU per hr CL64eR advans s D WAS H E R 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com 10 F 63 1 2 gt F 13 e 363 4 36 3 4 OPTIONAL VENT j 1 HOOD W DAMPER OPTIONAL EXTENDED VENT HOOD W DAMPER i 84 5 8 434 4 pre
21. s from entering the pump Hinged Door Seals and stainless steel labyrinth Seal for drip free operation Door Actuated Drain Closure Closing the door automatically actuates drain closure eliminates extra manual steps ensures that closure is in the correct position AVAILABLE OPTIONS AND ACCESSORIES Flexibility is synonymous with Hobart CLeR dish washers If your operation demands a dishwasher with a vent hood an extended hood a power Gas Burners with Natural Gas 2 78 000 scrapper just specify the combination of options that Electric Heating Unit Size Used Regulated 25 KW 15 10 SUH your mess Booster Heater Final Rinse 30 KW Rinse Minutes operated during hour of maximum operation 60 Final Rinse Flow Gals per min At 20 PSI Flow Pressure 2 2 Final Rinse Flow Gals per hr MAXIMUM At 15 PSI Flow Pressure 114 At 20 PSI Flow Pressure 132 Rinse 20 PSI Flow Pressure Hot Water Sanitizing Gal Rack 39 180 F Steam Consumption Pounds per hr MAXIMUM Approx 30 10 per hr 1 boiler BHP e Dishwasher based on 20 PSI steam and P Z x on customer supplying final rinse water at 180 F maximum 130 Steam Booster if used 20 PSI steam Side Loader Save up to 20 square feet in the 20 PSI water flowing 130 F entering dishroom layout with an optional CLeR Side Loader water raised to 180 F min 63 Racks are indexed 90 into the dishwasher automati Exhaust R
22. ture debossed anti clogging nozzles for superior result Page 2 of 12 The Energy Recovery System captures escaping heat and steam from the exhaust air and uses a heat exchanger to recycle it into energy This free energy is used to preheat the incoming water supply before it enters the booster heater The ground temperature water passes through a heat exchanger positioned directly in line with the machine s unload exhaust system to capture the energy from the exhaust air and ware leaving the machine to elevate the temperature of the water to 110 before it enters the booster heater Opti RinSe Hobart s exclusive Opti RinSe significantly reduces operating cost by reducing rinse water and the energy required to heat the water The unique spray pattern uses large droplets to more efficiently sanitize the ware Built in Pressureless Stainless Steel Booster Heater Interwired and interplumbed Saves on installation and saves floor space Simplifies operation with just one Switch to power dishmachine and booster F 40293 CL6a4eR advans s Dishwasher 701 S Ridge Avenue Troy OH 45374 1 888 4HOBART www hobartcorp com CL64eR advans s DISHWASHER OTHER STANDARD FEATURES Thermal Layer Curtains help keep the heat inside the machine Ball Detent Clutch Conveyor Drive for maximum protection against conveyor jams Integrated Removable Pump Intake Screen to offer the ultimate guard of keeping debri

Download Pdf Manuals