Home
Heath Zenith SL-5210 User's Manual
Contents
1. Mode Switching Summary Move ON TIME Switch to 1 5 or 10 minutes Flip switch off for one second then back on MANUAL MODE k i If you get confused while switching modes turn the power NOTE The Drip Loop is neccessary to prevent rain from ft for one minute then back on After the calibration time running down the cord to the Sensor Module 1 2 min the control will be in the AUTO mode O 2007 HeathCo LLC 595 4991 07 Drip Loop INSTALLATION IMPORTANT TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX to avoid electrical shock Remove the fixture and fixture strap if present and dis connect the wiring Aten power off before wiring Circuit Breaker House Wiring Sensor Wiring Light Control Typical Wiring e Connect the RED light control wire to the BLACK fixture wire e Connect the BLACK house wire to the BLACK light control wire e Connect the WHITE light control wire to both the WHITE house wire and the WHITE fixture wire If used join the grounding wire from the power source to the fixture grounding wire usually a bare wire Secure at the junction box grounding screw Connect additional lamps up to 500 W to the white and red control wires O Plug the sensor cord into the switch module The sensor cord s plug is polarized for proper installation Place the Switch Module into the junction box Before mou
2. TEST ON TIME SENS MIN MAX 10 5 1 TEST Parte de abajo del detector Evite apuntar el control hacia Fuentes de agua u objetos que cambian r pidamente de temperatura tales como conductos de calefacci n y acondicionadores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales dom sticos o el tr fico puedan activar el control Los objetos grandes cercanos y de colores resplan decientes que reflejan la luz del d a pueden hacer que el detector se apague No apunte otras luces hacia el detec tor e e 110 15m 18m Alcance M ximo Angulo de Cobertura M xima 595 4991 07 El detector es menos sensible del movimiento que se dirige hacia l Movimiento U CT Detector Lo menos sensible Lo m s sensible w Apunte el detector hacia abajo para poca cobertura O Camine por el rea a protegerse y d se cuenta d nde est cuando se prende la luz Mueva la cabeza del detector hacia arriba hacia abajo o hacia los lados para cambiar el rea de protecci n O Fije la sensibilidad SENS como necesite Demasiada sensibilidad puede aumentar las falsas alar mas Use el Aumento de Distancia para m s protecci n O Fije el per odo de tiempo ON TIME que la luz debe quedarse prendida despu s de detectar movimiento 1 5 6 10 minutos Apunte el detector
3. EN PARTICULAR Y ESPECIFICAMENTE EN LUGAR DE TODOS LOS DA OS ESPECIALES INDIRECTOS INCIDENTALES Y CONSECUENTES LA REPARACI N O EL REEMPLAZO DEBER A SER LA NICA SOLUCI N DEL CLIENTE Y NO HABR RESPONSABILIDAD POR PARTE DE HEATHCO LLC POR CUALQUIER DA O ESPECIAL INDIRECTO INCIDENTAL O CONSECUENTE INCLUIDOS PERO NO LIMITADOS A CUAL QUIER PERDIDA DE NEGOCIO O GANACIAS SEAN O NO PREVISIBLES Algunos estados o provincias no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada puede que no se aplique a Ud Por favor guarde su recibo de venta fechado se lo requiere para cualquier solicitud de garant a 8 595 4991 07 Hea Zenith FONCTIONNEMENT Mode Temps en circuit En fonction jour nuit Commande de luminaire ss 5 Secondes i X d coratif par d tection Manuel au choix amanecer x Revient au mode automatique au lever du soleil de mouvement Note Apr s la mise en circuit attendre environ 11 2 minute Mod le SL 5210 pour que les circuits compl tent leur talonnage Caract ristiques En e Allume l appareil d clairage lorsqu un mouvement est Amener en position d essai TEST ON TIME d tect interrupteur de temps en circuit ON TIME Eteint automatiquement l clairage du bas du detecteur 1051 TEST e Photocellule qui maintie
4. m s arriba para mayor cobertura ESPECIFICACIONES Alcance Hasta 18 m varia de acuerdo a la temperatura que le rodea Angulo de detecci n Hasta 110 Carga El ctrica Hasta 500 Vatios M ximo de luz incandescente Requisitos de Energia 120 VCA 60 Hz Fases de Operaci n PRUEBA AUTOMATICO y SO BRECONTROL MANUAL Retardo de Tiempo 1 5 10 minutos Sensibilidad Ajustable HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligaci n de tener que incorporar nuevas caracter sticas en los productos vendidos con anterioridad GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se El interruptor de luz est apagado La luz se queda 1 Unfaro est colocado demasiado cerca al detector enciende El faro est flojo o fundido prendida con O apunta a objetos cercanos que hace que el calor El fusible est quemado o el cortacircuitos est tinuamente active el detector Reposicione la l mpara lejos del apagado detector o de los objetos cercanos La desconexi n de luz del d a est en efecto El control de luz est apuntando hacia una fuente Compru belo al anochecer de calor tal como un conducto de aire de secadora Alambrado incorrecto si sta es una nueva insta O hacia una superficie con pintura brillante y que laci n refleja el c
5. al Servicio T cnico por favor tener lista la siguiente informaci n N mero de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANT A LIMITADA A 5 ANOS Esta es una Garant a Limitada que le da a Ud derechos legales espec ficos Usted puede tambi n tener otros derechos que var an de estado a estado o de provincia a provincia Por un per odo de 5 a os desde la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de f brica o mano de obra ser corregido sin cargo para Ud No cubierto Servicio de reparaci n ajuste y calibraci n debido al mal uso abuso o negligencia bombillas bater as u otras partes fungibles no est n cubiertas por esta garant a Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidar n esta garant a en su totalidad Esta garant a no incluye reembolso por inconveniencia instalaci n tiempo de instalaci n perdida de uso servicio no autorizado o costos de transporte de retorno Esta garant a cubre solamente los productos ensamblados por HeathCo LLC y no se extiende a otros equipos o componentes que el consumidor usa junto con nuestros productos ESTA GARANT A ESTA EXPRESAMENTE EN LUGAR DE OTRAS GARANT AS EXPRESADAS O SOBREENTENDIDAS INCLUYENDO CUALQUIER GARANT A REPRESENTACION O CONDICI N DE COMERCIABILIDAD O QUE LOS PRODUCTOS SE ADAPTEN PARA CUALQUIER PROPOSITOOUSO
6. interruptor Mueva el interruptor de tiempo ON TIME a 1 5 6 10 minutos Apague el interruptor por un segundo y pr ndalo de nuevo Siseconfunde mientras cambia de fases apague la electricidad por un minuto y pr ndala de nuevo Despu s del tiempo de cali braci n 1 min el control estar en fase AUTO MATICA 595 4991 07 S INSTALACION IMPORTANTE Antes de empezar la instalaci n APAGUE TODA LA CORRIENTE AL CIRCUITO DE LUZ EN EL ROMPECIRCUITO O CAJA DE FUSIBLES para evitar un choque el ctrico O Quite la l mpara y la cinta de montar si alguna y suelte el alambrado Apague la corriente antes de alambrar Rompecircuito O Caja Fusible Blanco A Negro Alambrado de Control M dulo de Interruptor Alambrado de Casa Diagrama del Alambrado Conecte el alambre ROJO del M dulo de Interruptor con el alambre NEGRO de la l mpara Conecte el alambre NEGRO del alambrado de la casa con el alambre NEGRO del M dulo de Interruptor Conecte el alambre BLANCO del alambrado de la casa con el alambre BLANCO del M dulo de Interruptor y el BLANCO de la l mpara Si lo usa junte el cable de a tierra que viene de la fuente de alimentaci n al cable de a tierra del aparato generalmente un cable desnudo Aseg relos en el tornillo de a tierra de la caja de empalme La corriente total controlada por el control no puede sobrepasar 500 vatios O Enchufe la linea de sens
7. le remettre en circuit Boucle d gouttement PRIORIT MANUELLE REMARQUE La boucle d gouttement est n cessaire Si vous ne savez plus dans quel mode se trouve l appareil pour emp cher l eau de pluie de s goutter le long du couper l alimentation pendant 1 minute puis la r tablir Apr s le cordon jusqu au module de d tection temps d talonnage la commande reviendra au mode AUTO 2007 HeathCo LLC 9 595 4991 07 F INSTALLATION IMPORTANT COUPER L ALIMENTATION DU CIRCUIT D ECLAIRAGE AU TABLEAU DES DISJONCTEURS OU DES FUSIBLES pour viter les chocs lectriques O Enlever le luminaire et la bride de connexion si pr sente et d connecter le c blage Couper l alimentation avant de travailler sur le c blage Tableau de disjoncteurs ou fusibles Serrae fils C blage de la maison Module de C blage du detecteur commutation Sch ma de c blage e Connecter le fil ROUGE du module de commutation au fil NOIR du luminaire e Connecter le fil NOIR du c blage de la maison au fil NOIR du module de commutation e Connecter le fil BLANC du c blage de la maison au fil BLANC du module de commutation et au fil BLANC du luminaire S il est utilis relier le fil de mise la terre de la source d alimentation au fil de mise la terre du luminaire habitu ellement un fil nu Assujettir la vis de terre de la bo te de jonction Connecter toute lampe suppl
8. mentaire jusqu 500 W aux fils blanc et rouge de la commande 10 Brancher le cordon du d tecteur dans le module de com mutation La fiche du cordon du d tecteur est polaris e pour une installation appropri e Placer le module de commutation dans la bo te de jonc tion Avant de monter le couvercle du luminaire s assurer que le cordon est bien plat et tout contre le mur pour viter de l endommager en r installant le luminaire Veiller ce que le manchon protecteur qui recouvre le cordon du d tecteur se prolonge l g rement au del du couvercle du luminaire R installer le luminaire Vers le luminaire Y O TES Module de commutation dans la bo te de jonction Bo te de jonction de 10 cm x 10 cm 4 po x 4 po Boucle d gouttement Montage du d tecteur Fixer le module du d tecteur au mur au moyen des vis fournies Disposer le d tecteur en dessous ou c t du luminaire Il peut tre n cessaire d incliner la t te du d tecteur vers le haut pendant le montage Renseignements importants concernant l installation Lorsque vous installez le capteur assurez vous que le fil surgit du dessous du support et forme une boucle d gouttement montr e ci dessus Ceci emp chera l eau de p n trer dans la t te du capteur ou la bo te de jonction 595 4991 07 ESSAI ET R GLAGE O Ramener l alimentation en circuit au tableau des di
9. ndar de 4 x 4 El SL 5210 incluye e El M dulo de Sensor y M dulo de Interruptor e Tres conexiones de alambre e Dos tornillos para el m dulo Instalaci n T pica L mpara Actual M dulo de Interruptor en Caja de Derivaci n Detr s de L mpara Sensor M dulo de Sensor Bucle ca do NOTA El Bucle de Goteo es necesario para evitar que la lluvia pase por el cable hasta el M dulo del Sensor O 2007 HeathCo LLC FUNCIONAMIENTO Fase Tiempo de encendido Trabaja d a noche Prueba 5 segundos x x Autom 1 5 10 minutos x Manual Hasta el amanecer x Se pone en Automatico al amanecer Cuando lo prenda por primera vez espere 1 2 minutos hasta que el circuito se calibre PRUEBA Ponga el interruptor de tiempo ON TIME al ON TIME fondo del detector en la posici n de prueba TEST 105 1 TEST AUTOMATICO Ponga el interruptor de tiempo ON TIME ON TIME en la posici n de 1 5 6 10 minutos lt tb 1051 TEST Para MODO MANUAL El modo manual funciona s lo por la noche porque la luz del d a pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vu lvalo a prender HE onda luego El modo manual funciona s lo cuando elinterruptor de tiempo ON TIME est en la posici n de 1 5 10 minutos 4 pr ndalo Resumen de las modalidades del
10. Heat Zenith OPERATION Mode On Time Works Day Night eres een Ea E Decorative Lig hti ng Manual Until Dawn x resets to Auto Mode at dawn Control Note When first turned on wait about 1 2 minutes for the circuitry to calibrate Model SL 5210 TEST Features ON TIME e Turns on lighting when motion is detected Putthe ON TIME switch on the bottom ofthe e Automatically turns lighting off sensor in the TEST position eae e Photocell keeps the lighting off during daylight hours Requirements ee e The light control requires 120 volts AC Put the ON TIME switch in the 1 5 or 10 ON TIME e If you want to use Manual Override the control must be minute position 7 gt wired through a wall switch 1051 TEST e Some codes require installation by a qualified electrician MANUAL MODE e Switch Module mounts into a standard 4 x 4 junction box The SL 5210 package includes e The Sensor Module and Switch Module e Three wire nuts e Two sensor module screws Manual mode only works at night because daylight returns the sensor to AUTO Flip the light switch off for one second then back on to toggle between AUTO and 1 Second OFF Typical Installation MANUAL MODE then Existing Light Fixture Manual mode works only with the ON TIME See Mods switch in the 1 5 or 10 position J ule In Junction Box Behind Light Fixture back on
11. alor Reposicione el detector Apunte de nuevo el detector para cubrir las reas deseadas La luz se Elcalorolaluz de las l mparas pueden estar pren prende y se diendo y apagando el control de luz Reposicione La luz se El control de luz puede estar instalado en un lugar apaga las l mparas lejos del detector prende durante relativamente oscuro El calor que se refleja de otros objetos pueden estar el d a El control de luz est en fase de Prueba Fije el afectando al detector Reposicione el detector interruptor del control a la posici n de TIEMPO El control de luz est en fase de Prueba y calen t ndose El prenderse y apagarse es normal bajo La luz se El control de luz puede estar detectando animales LR estas condiciones prende sin peque os o el tr sito de autom viles Reapunte el ninguna raz n detector aparente La Sensibilidad es demasiado alta Reduzca la sensibilidad SERVICIO T CNICO Favor de llamar al 1 800 858 8501 s lo para hablar en ingl s para pedir ayuda antes de devolver el producto a la tienda Si tiene alg n problema siga esta gu a Usted puede tambi n visitar nuestro sitio Web www hzsupport com Si el proble ma contin a llame al 1 800 858 8501 s lo para hablar en ingl s de 7 30 AM a 4 30 PM CST L V Usted puede tambi n escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio T cnico Si se llama
12. e bas ou les c t s pour modifier la zone de couverture O R gler la sensibilit SENS au besoin Une trop grande sensibilit risque d augmenter le nombre de d clenchements intempestifs O R gler la minuterie TIME selon la Pointer le d tecteur vers le bas pour r duire la couverture p riode pendant laquelle vous voulez Pointer le quela lampe demeure allum e apr s d tecteur vers d tection du mouvement 1 5 ou 10 le haut pour minutes augmenter la couverture FICHE TECHNIQUE POPC unas Jusqu a 18 m varie selon la temp rature environnante Angle de d tection Jusqu a 110 Charge lectrique Jusqu a 500 Watts Maximum incandescent Courant requis lampes teintes e 120 V c a 60 Hz Modes de fonctionnement Essai automatique et priorit manuelle Minuterie 1 5 ou 10 minutes SENSIDIIT cercar R glable HeathCo LLC se r serve le doit d abandonner tout produit et d en changer les sp cifications en tout temps et sans con tracter quelque obligation que ce soit quant a l incorporation de nouvelles caract ristiques aux produits d j vendus SYMPT ME GUIDE DE D PANNAGE CAUSE POSSIBLE SYMPT ME CAUSE POSSIBLE La lampe ne s allument pas La lampe s allument le jour La lampe s allument sans raison apparente Linterrupteur d clairage est en position hors circuit Le
13. e temperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting daylight may trigger the shut off feature Do not point other lights at the sensor e 110 5 ft 60 ft Maximum Coverage Angle Maximum Range 595 4991 07 The detector is less sensitive to motion directly towards it and more sensitive to across motion D Sensor a Least Sensitive Most Sensitive O Walk through the coverage area noting where you are when the lights turn on Move the sensor head up down or sideways to change the coverage area O Adjust the SENSITIVITY as needed Too much sensitivity may increase false triggering Aim Sensor Down for Short Coverage O Setthe amount of TIME you want the lights to stay on after motion is detected 1 5 or 10 minutes Aim Sensor Higher for Long Coverage SPECIFICATIONS Range dw ade ue Up to 60 feet varies with surround ing temperature Sensing Angle Up to 110 Electrical Load Up to 500 Watts Maximum Incan descent Power Requirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL OVER RIDE Time Delay 1 5 10 minutes Sensitivity Adjustable HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any ob
14. er la commande d clairage R orienter le d tecteur La commande d clairage est en mode essai et se r chauffe Le clignotement est normal dans ces deux cas trop sensible R duire la sensibilit SERVICE TECHNIQUE Veuillez faire le 1 800 858 8501 service en anglais seulement pour obtenir de l aide avant de retourner l article au magasin En cas de probl me suivez ce guide Vous pouvez aussi visiter notre site Web www hzsupport com Si le probl me persiste composez le 1 800 858 8501 service en anglais seulement entre 7 h 30 et 16 h 30 HNC du lundi au vendredi Vous pouvez aussi crire au HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants port e de main num ro du mod le date d achat et endroit de l achat Aucune pi ce de rechange n est disponible pour ce produit GARANTIE LIMIT E DE 5 ANS Il sagit d une Garantie limit e qui vous conf re des droits juridiques sp cifiques Vous pouvez galement jouir d autres droits variables d une province l autre Pendant une p riode de 5 ans compter de la date d achat toute anomalie de fonctionnement imputable un vice de mat riau ou de main d oeuvre sera corrig e gratuitement Exclusions de la garantie R parations r glage et calibrage dus une mauvaise utilisation un mauvais traitement ou la
15. ligation to incorporate new features in products previously sold Light will not come on Light comes on in daylight Light comes on for no apparent reason TU 1 2 3 4 5 6 1 TROUBLESHOOTING GUIDE Light switch is turned off Flood light is loose or burned out Fuse is blown or circuit breaker is turned off Daylight turn off is in effect recheck after dark Incorrect circuit wiring if this is a new installation Re aim the sensor to cover desired area Light control may be installed in a relatively dark location Light control is in Test Set control switch to an ON TIME position Light control may be sensing small animals or automobile traffic re aim sensor Sensitivity is set too high Reduce sensitivity POSSIBLE CAUSE Light stays on continuously Light flashes on and off i A sensor is positioned too close to the lamp or pointed at nearby objects that cause heat to trig ger the sensor Reposition the lamp away from the sensor or nearby objects Light control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective surface Reposition sensor Heat or light from the lamp may be turning the light control on and off Reposition the sensor away from the light Heat being reflected from other objects may be affecting the sensor Reposition sensor Light control is in the Test mode and warming up Flashing is normal under these condi
16. n gligence Les ampou les les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autoris ou la modification du produit ou d un ou l autre de ses composants fournis invalidera totalement la pr sente garantie Cette garantie n inclut pas le remboursement pour le d rangement l installation le r glage la perte d utilisation le service non autoris ou les frais d exp dition pour le renvoi de la marchandise La garantie ne couvre que les produits assembl s HeathCo LLC et ne s tend pas aux autres quipements et composants que le client pourrait utiliser conjointement avec nos produits CETTE GARANTIE TIENT EXPRESS MENT LIEU DE TOUTES AUTRES GARANTIES EXPLICITES OU IMPLICITES Y COMPRIS DE TOUTE GARANTIE DE REPR SENTATION O DE CONDITION DE CONVENANCE LA COMMERCIALISATION O L EFFET QUE LES PRODUITS CONVIENNENT UN BUT OU UNE UTILISATION PARTICULI RE ET SP CIFIQUEMENT DE TOUS DOMMAGES SP CIAUX DIRECTS INDIRECTS OU SECONDAIRES LE REMPLACEMENT OU LA R PARATION CONSTITUENT LE SEUL RECOURS DU CLIENT ET HEATHCO LLC NE POURRA TRE TENUE RESPONSABLE DE TOUS DOMMAGES SP CIAUX DIRECTS INDIRECTS OU SECONDAIRES Y COMPRIS SANS S Y LIMITER LES PERTES COMMERCIALES ET PERTES DE PROFIT QU ELLES SOIENT PR VISIBLES OU NON Certaines provinces n autorisent pas l exclusion ou la limitation des dommages indirects ou secondaires et la limitation ou exclusion ci dessus pourrait ne pas s ap
17. nt l clairage teint pendant la AUTOMATIQUE p riode de lumi re du jour Amener l interrupteur de temps en circuit ON TIME Exigences ON TIME la position correspondant 1 el Is e La commande d appareil d clairage requiert une source 5 ou 10 minutes d alimentation de 120 V c a IWS TIER e Si vous d sirez utiliser la priorit manuelle la commande PRIORIT MANUELLE doit tre c bl e via un interrupteur mural e Certains codes requi rent que cette installation soitr alis e Le mode manuel ne fonctionne que la nuit par un lectricien qualifi parce que la lumi re du jourremet le capteur e Le module d interrupteur se monte dans une bo te de jonc en mode AUTO tion standard de 10 cm x 10 cm 4 po x 4 po L ensemble SL 5210 comprend Mettre l interrupteur hors circuit pendant Se ee e le module de d tection et le module de commutation une seconde plus en circuit pour alterner puis e trois 3 serre fils entre les modes AUTO et MANUEL e deux 2 vis de module de d tection Le mode manuel ne fonctionne que lorsque Installation type l interrupteur ON TIME est aux positions Luminaire existant 1 5 ou 10 nouveau en circuit Module de com mutation dans la bo te de jonc tion derri re le luminaire R sum du mode de commutation Placer l interrupteur ON TIME 1 5 ou 10 minutes Cordon du d tecteur Mettre l interrupteur hors circuit pendant une seconde puis
18. nting the fixture cover make sure that the cord is flat and smoothly placed against the wall so that the cord will not be damaged when the fixture is re installed Make sure that the protective sleeve over the sensor cord extends slightly beyond the fixture cover O Reinstall the fixture a To Light Fixture 4 x a Junction Box 4 A O o Switch Module In Junction Box N N O Drip Loop Mounting Sensor Attach the sensor module to the wall with the screws provided Place the sensor below or to the side of the fixture It may be necessary to tilt the sensor head up while mounting Important Installation Information When installing the sensor make sure the wire comes out of the bottom of the bracket and forms a drip loop shown above This will prevent water from entering the sensor head or junction box 595 4991 07 TEST AND ADJUSTMENT O Turn on the circuit breaker and light switch NOTE Sensor has a 1 2 minute warm up period before it will detect motion When first turned on or when switching modes wait 1 2 minutes O Turn the SENSITIVITY SENS control to the mid position and the ON TIME control to the TEST position ON TIME SENS C gt lt MIN MAX 105 1 TEST Bottom of Sensor Avoid aiming the control at Objects that chang
19. or en el m dulo de interruptor El enchufe de la l nea est polarizada para instalarse correctamente O Cuidadosamente ponga el M dulo de Interruptor enla caja de derivaci n Antes de montar la l mpara asegure que la l nea de sensor est contra la pared de modo que no ser da ada por la cubierta cuando se monte la l mpara Asegure que el tubo protectivo de la l nea se extiende un poco m s all de la cubierta O Monte la l mpara Hacio Caja de empalmes L mpara de 4 x 4 L O ES M dulo de Interruptor en Caja de Derivaci n Bucle Ca do Montar Sensor O Monte el sensor aproximadamente cinco pies por encima de la tierra Ponga el sensor debajo de la l mpara Monte el sensor en la pared con los tornillos prove dos Informaci n Importante de Instalaci n Cuando instale el detector aseg rese que el cable salga por debajo del soporte y forme un lazo de goteo que se muestra arriba Esto evitar que el agua entre al cabezal del sensor o a la caja de empalme 595 4991 07 PRUEBA Y AJUSTE O Prenda el cortacircuitos y el interruptor de luz NOTA El detector tiene un per odo de cerca de 1 2 minu tos de calentamiento antes de detectar movimiento Cuando lo prenda por primera vez espere 1 2 minutos O Gire el control de sensibilidad SENS a el medio y el control de tiempo ON TIME a la posici n de prueba
20. overs only ACE assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF ACE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Please keep your dated sales receipt it is required for all warranty requests 4 595 4991 07 Heati Zenith Control De Luz Decorativo Sensor De Movimiento Modelo SL 5210 Caracter sticas Prende la luz cuando detecta movimiento Apaga la luz autom ticamente La fotoc lula mantiene la luz apagada durante el d a Requisitos El control de luz requiere 120 VCA Para usar el Sobrecontrol Manual conecte el control con un interruptor e Algunos c digos requieren instalaci n por un electri cista calificado Instale el m dulo del interruptor en una caja de empalmes est
21. pliquer vous Veuillez conserver le re u portant la date d achat vous en aurez besoin pour toutes vos demandes li es la garantie 12 595 4991 07
22. s projecteurs sont br l s ou desserr s Le fusible du circuit a saut ou le disjoncteur est en position hors circuit La fonction de mise hors circuit la lumi re du jour est engag e Rev rifier quand il fait nuit Mauvais c blage s il s agit d une nouvelle installation Mauvaise orientation R orienter le d tecteur pour obtenir la couverture d sir e La commande d clairage estinstall e dans un endroit relativement sombre La commande d clairage est en mode essai Placer l interrupteur ON TIME La commande d clairage peut d tecter de petits animaux des arbres agit s par le vent ou la circula tion automobile R orienter le d tecteur La commande de sensibilit est plac e sur un r glage La lampe restent allu m es continu ellement La lampe clignotent Un d tecteur se trouve trop pr s de la lampe ou point sur des objets environnants dont la chaleur d clenche le d tecteur Repositionner la lampe l cart du d tecteur ou des objets environnants Le d tecteur de la commande d clairage pointe vers une source de chaleur comme un vent d a ration un vent de s cheuse ou une surface peinte de couleur vive r fl chissant la chaleur R orienter le d tecteur La chaleur ou la lumi re des projecteurs peut al lumer et teindre alternativement la commande d clairage loigner le d tecteur de la lampe La chaleur qui est r fl chie par d autres objets peut affect
23. sjoncteurs ou fusibles et placer l interrupteur d clairage sur ON REMARQUE Le capteur doit se r chauffer 1 2 minute avant de pouvoir d tecter le mouvement Lorsque l appareil est mis en circuit ou chang de mode attendre 1 1 2 minute O Tournerlacommande de sensibilit SENS en position interm diaire et la commande ON TIME en position TEST ON TIME 105 1 TEST lt MIN MAX Dessous du d tecteur Eviter de pointer le d tecteur endirection d objets dontla temp rature change rapidement tels que des bouches d air chaud et des climatiseurs De telles sources de chaleur peuvent provoquer des d clenche ments intempestifs vers des endroits o des animaux des v hicules ou des passants peuvent d clencher la commande sur de grands objets clairs proximit qui r fl chissent la lumi re du jour et risquent de d clencher le dispositif d arr t Ne pas pointer d autres appareils d clairage vers le d tecteur 110 18m Port e maximale Angle de couverture maximale 595 4991 07 Le d tecteur est moins sensible au mouvement qui survient dans sa direction qu au mouvement transversal Mouvement A D tecteur Le moins sensible Le plus sensible O Marcher dans la zone de couver ture en notant quel moment la lampe s allume D placer la t te du d tecteur vers le haut l
24. tions TECHNICAL SERVICE Please call 1 800 858 8501 English speaking only for assistance before returning product to store If you experience a problem follow this guide You may also want to visit our Web site at www hzsupport com If the problem persists call for assistance at 1 800 858 8501 English speaking only 7 30 AM to 4 30 PM CST M F You may also write to HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product FIVE YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of five years from the date of purchase any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or return shipping charges This warranty c