1. Chandler Reach In Unit Coolers REFRIGERATION CHANDLER January 2001 Replaces CH B 01 Bulletin CH B 01A Heatcraft Inc 2001 Model VA Reach In Unit Cooler APPLICATION The Model VA unit cooler is a deluxe unit designed for use in small reach ins back bar and under counter refrigerators and many other applications where a small compact unit is required The thermal expansion valve mounts inside the unit The unit can be mounted from the ceiling or off the back wall or end walls FEATURES Textured aluminum cabinet Molded Lexan fan guard Improved drain pan overlaps coil surface to catch all condensate Stainless steel screws prevent rust streaks Plate type aluminum fins with full collars on expanded copper tubes Expansion valve mounts inside cabinet Performance Electrical Data Pigtail leads in junction box Internal junction box for electrical connection e Motors are thermally protected and permanently lubricated Optional corrosion resistant coated coil available VAK for optimum protection in corrosive environments NSF standards UL listed for the United States and Canada UL classified to CONNECTIONS INCHES APPROX MOTOR DATA CO MODEL BTUH 115 1 60 208 230 1 60 COIL VA 10 FTD CFM QTY TOTALFLA TOTALFLA INLET 06 600 155 1 0 8 0 4 1 2FN 08 800 130 1 _ 0 8 0 4 1 2EN 12 1200 265 1 1 6 0 8 1 2FN 17 1700 245 2 1 0 0 5 1 2FN DIMENS
2. LBS 09 850 1275 190 45 29 1 2EN 3 sID 9 12 1150 1725 250 45 55 ___ 1 2EN 81D 10 15 1500 2250 310 1 10 55 1 2FN 3 sID 14 PHYSICAL DATA MODEL DIMENSIONS In U_ H W D A B C 09 oa ELS 87 8 6 4 31 2 12 81 2 174 2 87 8 12 4 94172 15 giya 17 1 2 10 7 8 12 4 91 5 DIMENSIONAL DIAGRAM WU s NOMENCLATURE 2 DRAIN O D Fitting 10 AIR OUT ji U U Dual Aire 1 Unit Cooler K 09 0 i Lona K Coated Coil 1 208 230 1 60 Optional Size WALL MTG ANGLE Unattached Models BBM BBL Back Bar Reach In Unit Cooler 4 APPLICATION The BB models are compact wall mounted units whose low height makes them ideal for undercounter reach in or drawer type fixtures The unit draws air in at the bottom and discharges out the front An optional air deflector is included and can be mounted over the center of the fan to direct air up and out The deflector can be field formed to direct the air where needed usually onto drop in trays of condiments in salad bar or sandwich preparation fixtures An S type mounting angle is included to position the unit 3 4 off the wall which gives optimum air circulation and performance The BBM medium temperature model is designed for 35 to 40 F fixture temperature with off cycle defrost The unit is designed to operate at 10 to 17 TD and 16 hours per day compressor run time The BBL low temperature model is
3. s KO ELECT 1 500 SIZE 09 ir In C k 7 8 DIA Model TA Thin Profile Air Defrost Reach In Unit Cooler APPLICATION c UL us Model TA is a thin profile unit which mounts in the top of a Pace refrigerator and makes the entire top shelf area usable The Men attractive low silhouette makes this unit cooler particularly desirable for display type refrigerators It can also be used in back bars under counter cabinets or wherever space is at a premium For 35 to 45 F fixtures at 10 F to 15 F TD applications with 16 hours maximum compressor run time per day FEATURES e Textured aluminum cabinet e Internal junction box for electrical connection e Molded Lexan fan guards and fan blades e UL listed for the United States and Canada UL classified to e Drain fitting mounted at 45 degree angle so drain can be run NSF standards through the back or bottom of refrigerator e Optional corrosion resistant coated coil available Model e Stainless steel screws TAK for optimum protection in corrosive environments e Motors thermally protected and permanently lubricated e Convenient moisture proof motor plug Performance Electrical Data MOTOR DATA CONNECTIONS INCHES APPROX MODEL BTUH 115 1 60 208 230 1 60 COIL SHIP WT TA 10 F TD CFM LT ES FLA RTS FLA INLET SUCTION DRAIN LBS Co i o RE CS CORRE CO a7 100 MO 2 T6 08 FN D OD 1 155 5500 650 JEN D t Models 43 and 55 use exter
4. 8OD 5 8OD 20 23 2300 255 3 2 4 1 2 1 2EN 3 80D 5 8OD 28 DIMENSIONAL DATA NOMENCLATURE MODEL DIMENSIONS INCHES oo i RAM K 13 AE RAMK H L M W _X Y Z RAM Air Flow 13 17 3 4 16 7 8 9 15 5 8 23 4 51 2 6 15 16 Mullion A 115 1 60 17 193 4 167 8 10 15 5 8 23 4 61 2 7 46 PARCOSICE B 208 230 1 60 23 193 4 231 4 10 22 25 16 61 2 7 15 16 K Coated En Coil N Size Adjustable Deflector AN 15 Dia Mounting Holes Optional Bracket Air In Model U Dual Aire Reach In Unit Cooler FEATURES e Textured aluminum cabinet e Full collar aluminum fins on expanded copper tubes e Detachable drain pan that is easy to clean e Molded 3 prong motor connector to save installation time and expense e Motors are thermally protected and permanently lubricated e Optional coated coil available Model UK for optimum protection in corrosive environments e All sizes UL component recognized and NSF approved Performance Electrical Data APPLICATION The U unit cooler is used wherever a small compact unit is required It can be mounted on the ceiling or wall The model U unit draws air through the front and discharges it out both sides to insure proper distribution of cool air and thus maintain a uniform box temperature ____ MOTOR DATA _ CONNECTIONS In APPROX _ MODEL __ BTUH CAPACITY 115 1 60V 208 230 1 60V COIL SHIPPING U 10 TD 15 TD CFMTOTALFLA TOTALFLA INLET SUCTION WT
5. 53 N Profile vintage Electric A 115 1 60 5 16 x 5 8 x 1 1 Defrost B 208 230 1 60 KEYHOLE SLOT 3 Size Model KMK Mullion Reach In Unit Cooler APPLICATION The KMK Mullion is ideal for under counter reach in refrigerators The thin line design allows the unit to be mounted behind the mullion with sufficient clearance for tray slides A down flow fan arrangement is used with air drawn in at the top and discharged at the bottom This design provides superior air circulation and insures uniform temperature throughout the cabinet This versatile design is also adaptable for mounting on the back wall or ends of a cooler The method of air circulation insures minimum box temperature rise when the cabinet doors are open Ideal for bottle goods and beverage coolers EXCLUSIVE CORROSION RESISTANT COATING IS STANDARD The finned coil is protected by a special dip coating that is baked on It prevents corrosion of the coil caused by acids that are present in many food service and storage coolers FEATURES e Textured aluminum cabinets PVC coated fan guard Stainless steel hardware Coils have full collar aluminum fins on expanded copper tubes Refrigerant connection knockouts provided on both ends of unit Expansion valve mounts inside the unit Performance Electrical Data MOTOR DATA MODEL BTUH 115 1 60 208 230 1 60 CO ADN IN KMK 10 F TD C ALSO CLASSIFIED AS A COMPONENT IN ACCORDANCE Motors are the
6. IONAL DATA MODEL NOMENCLATURE VA K OS BE J L vintage 1 VA Reach In Unit Cooler K Coated Coil Optional Size B C 131 4 45 16 131 4 45 16 183 4 5 16 143 4 51 4 DIMENSIONS INCHES A 115 1 60 B 208 230 1 60 2 750 ELECTRICAL CONNECTION A Wh the ff 442 O D DRAIN F 33 8 3 8 3 8 4 SHIP WT SUCTION DRAIN LBS 3 8ID 1 20D 9 3 8ID 1 20D 9 3 8ID 1 20D 14 1 2ID 1 20D 11 H J K W 67 8 51 4 81 8 12 2 67 8 51 4 81 8 121 4 8 47 8 81 8 18 93 4 6 16 101 2 14 OPTIONAL MOUNTING FROM TOP 5 8 x 5 16 x 1 B Model C High Profile Reach In Unit Cooler APPLICATION Here is the ideal unit for refrigerated reach ins It mounts to the top of the refrigerator and discharges cold air against the back wall With this air flow pattern the air is not blasted on the product but is diffused along the back wall and then gently drawn across the product as it returns to the unit Thus uniform temperatures are maintained throughout the e UL us refrigerator In addition door sweating and refrigeration loss msocussreo due to door opening is greatly reduced because the air is not we or discharged against the doors FEATURES e Textured aluminum cabinet Molded Lexan fan guard Drain fitting at 45 degree angle so drain can be run through Full collar aluminum fins on expanded copper tubes bottom or back of refrigerator Internal junction box with pigtail leads for elect
7. Y TOTALFLA TOTAL FLA NOMENCLATURE 09 900 1350 130 1 0 8 0 4 BIO KO AE 13 1300 1950 240 2 1 6 0 8 oo Le 18 1800 2700 255 1 1 0 0 5 A 115 1 60 25 2500 3750 460 2 2 0 1 0 K ee Sn B 208 230 1 60 35 3500 5250 425 2 20 1 0 Optional 45 4500 6750 550 2 2 0 1 0 Size 55 5500 8250 730 1 2 1 1 1 DIMENSIONAL DATA APPROX BTO K SHIP MODEL CONNECTIONS INCHES DIMENSIONS INCHES WT NO INLET SUCTION DRAIN A B C D E F G H J K L M LBS 09 1 2 FN 1 2ID 20D 16 s 19 s 79 16 4 DE fe P i Pal 47 6 ASS S s 21 2129 3 12 13 2EN 2ID 1 2OD 16 s 191 8 7 16 4 25 16 9 16 2 4 5 4 44 2 8 8 21 2 2 8 14 18 Y2EN 1D 120D 16t s 191 s 7 16 4 2 6 P x 22 4 Be fa 4 amp 2 6 s 21 2 2 8 15 25 1 2 FN 1 2I1D 1 20D 181 s8 261 8 111 16 4 25 16 131 16 2 41 63 4 51 2 121 8 31 2 25 8 23 35 1 2EN 2ID 1 2O0D 181 8 261 s 111 16 4 25 16 131 16 25 4 6 4 51 2 121 8 31 2 2 8 24 45 1 2EN 1 2ID_ sOD 21 8 291 s8 11 16 6 37 16 14 16 3 2 91 4 8 13 8 D s 41 4 34 55 1 2EN 1 21D 8OD 21 8 29 s 11 16 6 37 16 14 16 3 2 81 2 8 13 s 53 8 41 4 34 Sizes 45 and 55 use external equalized expansion valve 1 23 64 DIA KO REFRIG CONN o But jh 1 23 64 DIA K O REFRIG CONN OPPOSITE SIDE k HEADER amp DRAIN END 5 8 x MOUNT 516 x 1 ING SLOT 7 8 DIA
8. designed for 0 to 10 F fixture temperature and has automatic electric defrost The unit is designed to operate at 8 to 15 TD with 18 hours per day compressor runtime The BBL has an incoloy sheath heater embedded in the bottom fin surface for efficient and fast defrosting A drain pan heater is included to insure complete condensate drainage A disc type sealed defrost termination fan delay control is mounted and wired Field connectors are located at the terminal board FEATURES e Molded Lexan fan blades and guards e Coils have copper tubes with aluminum fins mechanically bonded for efficient heat transfer The coils are dehydrated and sealed e Textured aluminum cabinet Performance Electrical Data MOTOR DATA DEFROST HEATERS MODEL BTUH 115 60 1 208 230 60 1 BB 10 FTD CFMQTY HP TOTALFLA TOTALFLA WATTS AMPS L10 1 000 90 1 1 150 0 8 04 275 27 Mil 1100 90 1 1 150 0 8 0 4 115 1500 180 2 11 150 16 08 350 35 M16 1 600 180 2 1 150 1 6 0 8 Dimensional Data APPROX MODEL DIMENSIONS INCHES SHIPPING BB W A B C D E F WT LBS L10 19 4 19 s 18 Vie ME 16 8 17 M11 19 4 19 s 18 12 51 7 fe 165 8 16 L15 261 4 255 8 24 2 24 48 16 87 8 23i 20 M16 26 4 255 8 24 2 24 488 16 85 8 23 19 _ ALSO CLASSIFIED gt AS A COMPONENT IN ACCORDANCE WITH NSF 7 1997 e Knockouts are conveniently located for refrigerant lines e Screws are hardened stainless steel wit
9. ed Coil B 208 A 60 a ote 5 16 DIA HOLE i Optional D C Size Model BTO Twin Flow Reach In Unit Cooler APPLICATION Twin flow unit coolers are ideal for temperatures of 35 F and higher Box temperatures are kept more constant throughout and fresh products last longer Seven sizes are available with BTUH from 900 to 5 500 at 10 TD Larger BTO sizes are suitable for large reach in and small step in or walk in coolers FEATURES e Compact two way design with medium velocity air flow Mounts flush to the ceiling and draws air in through the fan and discharges out both sides Air pattern reduces air loss when doors are opened and the medium velocity reduces product drying Textured aluminum cabinet Stainless steel fasteners Molded Lexan fan guards safety approved Drain pan and fan panel is easily removed for installation and servicing Performance Electrical Data ALSO CLASSIFIED AS A COMPONENT IN ACCORDANCE H NSF 7 1997 Coils are copper tube with aluminum fins e Expansion valve mounts inside the cabinet Internal junction box is provided for electrical connection e Motors are thermally protected and permanently lubricated UL listed for the United States and Canada UL classified to NSF standards Optional corrosion resistant coated coil available Model BTOK for optimum protection in corrosive environments BTO K MOTOR DATA MODEL BTUH 115 1 60 208 230 1 60 NO 10 T D 15 T D CFM QT
10. h a bright zinc plating e Expansion valve mounts inside the cabinet and connections are sweat type e Motors are thermally protected and permanently lubricated e Master units include the basic unit plus factory mounted Sporlan FV1 5C R 22 1 4 x 1 2 sweat expansion valve Sporlan E3S 1 4 x 1 4 sweat solenoid and Ranco A 30 temperature control Also right hand piping extended 8 12 outside the housing sealed and pressurized to 20 30 PSI A 1 4 O D liquid feed to slave is included e Slave units include the basic unit plus factory mounted Sporlan FV1 5C R 22 1 4 x 1 2 sweat expansion valve with left hand piping extended 8 12 outside the housing sealed and pressurized to 20 30 PSI NOMENCLATURE BB L S 10 AA 115 60 1 208 230 60 1 BB Back Bar LRevision Unit Cooler AMPS A 115 1 60 14 L Low Temp Unit 5 p Uni i M Med Temp Unit B 208 230 1 60 1 7 Blank Standard Unit S Slave Unit ee M Master Unit TYPICAL m a SECTION one OF SANDWICH STATION i MODEL BBM 1 4 Dia Mtg Holes 4 Places 5 Vy Electrical Both Ends Deflector shipped loose 1 6 Air Flo Tubing Opposite End Tubing R Mounting J Bracket 2 Required 11 Visit our web site at www heatcraftrpd com for Technical Literature Online Since product improvement is a continuing effort at Chandler we reserve the right to make changes in specificatio
11. nal equalized expansion valve Dimensional Data MODEL DIMENSIONS INCHES TA eS ee ee ee TS De E Ge Is ee AS on ap os is de in 14 a os its ee ae 2 a S 15 Lin 14 2 13 20 5 4 2 1094 1004 Mn 49e S1 a 15 Bfas 14 2 W A REAR HANGERS SPACE F UNIT 2 FROM WALL L Raul C iiu T SUCTION LINE 5 16 19 32 SEE y a S B 1 2 0 0 A3 STE DRAIN ni E CONNECTION ELECTRICAL NOMENCLATURE ne A Thin Profil Th NES TA Thin Profile Air Defrost vantage ES i L___A 115 1 60 5 16 x 5 8 x 1 K Coated Coil Optional Size Model TL Thin Profile Electric Defrost Reach In Unit Cooler APPLICATION The TL low temperature unit cooler has a completely Ut u automatic defrost system Mounted in the top of a we couse refrigerator its extremely compact cabinet makes it possible to utilize the entire top shelf area for storage Having a normal operating range of 15 F to 20 F this unit is ideally suited for such applications as commercial freezers ice cream boxes and bakery freezers FEATURES e Electric defrost insures positive heat source e Built in fan delay allows coil to be chilled before returning to the normal cooling cycle Defrost terminates on coil temperature eliminating excessive defrost period Defrost termination and fan delay control terminal block Internal junction box for electrical connection and junction box are mounted inside the cabinet Plate type aluminum fins
12. ns without notice A Product Line of Heatcraft Inc Refrigeration Products HANDLE 2175 West Park Place Blvd Stone Mountain GA 30087 REFRIGERATION 770 465 5600 Fax 770 465 5990 1 2
13. ree angle This feature provides excellent air distribution over drop in trays or containers Food in the trays and containers stays colder lasts longer and retains the desired appearance The deflector can be adjusted to distribute air out both sides when used as a mullion unit EXCLUSIVE CORROSION RESISTANT COATING IS STANDARD The finned coil is protected by a special dip coating that is baked on to prevent corrosion of the coil by acids that are present in salad dressings spiced meats and other food products FEATURES e Textured aluminum cabinet e PVC coated fan guard e Stainless steel hardware e Coils have full collar aluminum fins on expanded copper tubes Performance Electrical Data MOTOR DATA MODEL BTUH 115 1 60 208 230 1 60 CONNECTIONS IN e Refrigerant connection knock outs provided on both ends of unit e Expansion valve mounts inside the unit e Motors are thermally protected and permanently lubricated Internal junction box for electrical connection Adjustable air deflector included provides different air patterns Air can be directed where its needed UL listed for the United States and Canada UL classified to NSF standards e Corrosion resistant coated coil for optimum protection in corrosive environments APPROX SHIPPING KMK 10 F TD CFM QTY TOTALFLA TOTALFLA INLET SUCTION DRAIN WT LBS 13 1300 180 2 1 6 0 8 1 2FN 3 80D 5 8OD 19 17 1700 170 2 16 0 8 1 2EN 3
14. rical Aluminum hangers automatically space the unit the correct connection distance from the back wall Motors are thermally protected and permanently lubricated UL listed for the United States and Canada UL classified to Room for expansion valve inside unit NSF standards Stainless steel screws prevent rust streaks Knockouts in sides and top plus openings in rear provide Optional corrosion resistant coated coil available Model CK maximum flexibility for electrical connection for optimum protection in corrosive environments Performance Electrical Data MOTOR DATA CONNECTIONS INCHES APPROX MODEL BTUH 115 1 60 208 230 1 60 COIL SHIP WT C 10 FTD CFM QTY TOTALFLA TOTAL FLA INLET SUCTION DRAIN LBS 13 1300 235 1 1 0 0 5 1 23EN 3 sID 1 20D 16 17 1700 250 1 1 0 0 5 T 5EN 37 sID 10D 17 23 2300 265 1 1 0 0 5 1 2EN 37 sID 1 20D 22 30 3000 480 2 2 0 1 0 T 5EN ID 10D 27 t143 4300 520 2 2 0 1 0 T 5EN TID 10D 40 TSize 43 uses external equalized expansion valve DIMENSIONAL DATA MODEL DIMENSIONS INCHES C A B C D W 13 125 s 123 s 117 16 13 s 141 14 17 155 8 123 8 147 16 13 8 Wee 23 211 s 123 s 211 16 7 3 23 4 30 261 8 123 s 2519 1 1 275 43 365 16 me an a 38 133 4 ai 13 16 21 2 6 ian 19 32 aS 1 8 p OO N 87 8 B 4135 8 ECT K O OPPOSITE SIDE AIR AIR IN Ih NOMENCLATURE r ELECT amp 7 C High ut E vintage Joe REFRIG K O S Unit cate 15 8 A 115 1 60 K Coat
15. rmally protected and permanently lubricated Internal junction box for electrical connection Adjustable air deflector included provides different air patterns Air can be directed where it is needed UL listed for the United States and Canada UL classified to NSF standards Corrosion resistant coated coil for optimum protection in corrosive environments APPROX SHIPPING FM ory saree FLA EURE FLA WT LBS 08 1 VANL 1700 1021 18 08 1 3EN 3 80D 5 800 20 DIMENSIONAL DATA MODEL DEN O EAE KMK DR CS IGN ee ee 2e Sr Gi OB Adjustable IR Deflector Standard NOMENCLATURE Coil Size 15 Dia Mounting Holes i Optional Bracket Standard Air Out K 13 A E KM KMK Mullion E Unit Cooler K Coated Vintage A 115 1 60 B 208 230 1 60 Model RAMK Reverse Air Flow Mullion Reach In Unit Cooler APPLICATION The model RAMK is ideal for under counter reach in refrigerators under counter drawer type refrigerators and salad bars The unit is suitable for mounting behind a mullion or ona wall An up flow air pattern is used with air drawn in at the bottom and discharged out the top This provides optimum temperature for drop in trays on salad bars or prep tables It also keep drawer stored product in premium condition An adjustable and detachable air deflector splash protector is included The deflector can be adjusted to direct the air up and out at a 45 deg
16. with full collars copper tubes Textured aluminum cabinet Coils are dehydrated and sealed e Molded Lexan fan guards safety approved Easy to install and maintain Knockouts provided on sides for electrical connections UL listed for the United States and Canada UL classified to opening in rear for coil connections NSF standards Performance Electrical Data BTUH 10 F TD MOTOR DATA APPROX TL SST SST CFM te a od WATTS AT a IAE 2U TION BAR LBS 09 1050 900 110 17 475 LEN 12 1880 11200 20 2 16 08 80082 EN GOD 19 16 1780 1600 210 2 16 0 8 700 61 3 0 1 N 1 21D 7 20D 23 21 2400 2100 240 1 10 05 1100 96 4 8 YEN 1 AD 1 2OD 24 28 3200 2800 355 3 12 1430 5 7 EN D 1 20D 27 735 2000 1 3500 420 2 10 1600 70 N pp 7 20D 38 _ 53 6100 5300 1595 3 15 1950 HEN 77D These models use external equalized expansion valves Stainless steel screws Motors are thermally protected and permanently lubricated DIMENSIONAL DATA MODEL DIMENSIONS INCHES E B Jo kK I M N P_ W le ne ee ne ee a e 2 W A REAR HANGERS SPACE F UNIT 2 FROM WALL L D g SUCTION LINE kods SUCTION LINE MIN SIZES 21 35 53 ae SIZES 09 12 16 28 M 4 19 32 ur LI A 4 L LA I ci WF gt H 1 125 gt ne NO 1 B a 149 O D 1p 222 DRAIN 7 B CONNECTION ELECT ELECTRICAL 09 28 CONNECTION CONNECTION 35