Home
Harbor Freight Tools Fuel Pump and Vacuum Tester Product manual
Contents
1. place cloths in fireproof container Clean all testing components of residual fuel before storing People with pacemakers should consult their physician s before using this product on a running engine Electromagnetic fields in close proximity to a heart pacemaker could cause interference or failure of the pacemaker In addition people with pacemakers should adhere to the following Caution is necessary when near the coil spark plug cables or distributor of a running engine The brass components of this product contain lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm California Health amp Safety Code 25249 et seq The warnings precautions and instructions discussed in this manual cannot cover all possible conditions and situations that may occur The operator must understand that common sense and caution are factors which cannot be built into this product but must be supplied by the operator Page 3 N Setup Instructions Park the vehicle in a well ventilated area If in a garage park the car so that the exhaust pipe faces out the garage entrance Leave garage door open at all times Place the transmission in Park Neutral and set the vehicle emergency brake Operating Instructions A Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this document including all text under subheadings therein before
2. PITTSBURGH Fuel Pump amp Vacuum Gauge Tester 93547 Pump Gauge Tester INSTRUCTIONS AND PRECAUTIONS Visit our website at http www harborfreight com AWARNING Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 800 444 3353 as soon as possible Copyright 2011 by Harbor Freight Tools All rights reserved No portion of this document or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this document may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included For technical questions or replacement parts please call 1 800 444 3353 Specifications 5 Pressure 0 28 IN Hg 0 70 cm Hg vacuum Gauge 0 10 PSIG 0 0 7 kg cm pressure Important Safety Information WARNING READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow instructions listed below may result in serious injury SAVE THESE INSTRUCTIONS 1 4 18 male x 1 8 27 female 1 8 27 male x 7 32 barbed 1 8 27 female x 3 8 18 male Brass Fittings General Safety Rules 1 Page 2 Ke
3. YER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Page 6 For technical questions please call 1 800 444 3353 SKU 93547 Parts List and Diagram a Vacuum Pressure Gauge 1 SKU 93547 For technical questions please call 1 800 444 3353 Pan Description aw ral 5 4 Adapter male female a 6 1 3 Adapter male barbed 4 1 9 Adapter female male 4 7 39 T type Adapter not shown Page 7 LIMITED 90 DAY WARRANTY Harbor Freight Tools Co makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance We shall i
4. ep bystanders children and visitors away while operating the Vacuum Pump Distractions can cause you to lose control Protect others in the work area from injury Stay alert Watch what you are doing and use common sense when operating the Vacuum Pump Do not use the tool while tired or under the influence of drugs alcohol or medication A moment of inattention while operating the tool may result in serious personal injury Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and jewelry away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Do not overreach Keep proper footing and balance at all times Proper footing and balance 10 For technical questions please call 1 800 444 3353 enables better control of the power tool in unexpected situations Use safety equipment Wear ANSI approved safety glasses underneath a full face safety shield Nonskid safety shoes hard hat or hearing protection must be used for appropriate conditions Do not force the tool Use the correct tool for your application The correct tool will do the job better and safer at the rate for which it is designed Store idle tools out of reach of children and other untrained persons Tools are dangerous in the hands of untrained users Maintain tools with care Keep tools dry and clean Properly maintained tools are less likely to bind and are easier
5. etween 17 and 22 IN Hg the green zone on the gauge 19 5 optimum A slow fluctuation between 14 and 22 IN Hg indicates that the carburetor needs adjustment or there are other engine problems Refer to the vehicle s service manual for normal and abnormal readings and adjustment or repair procedures Other possible engine problems can be diagnosed as follows When the gauge pressure drops intermittently about 4 IN Hg it could be an indication of sticky valves Remove the Rubber Hose 2 add a few drops For technical questions please call 1 800 444 3353 of penetration oil to the manifold and test again If the valves stop sticking valves need to be cleaned A constant low reading on the gauge could indicate a burnt valve s If the gauge pointer pulsates rapidly when the engine speed is raised it could indicate weak valve springs or poorly seated valves At idle engine speed the gauge pointer pulsates but at higher speeds the pointer is steady this could be an indication of loose valve stem guides When the gauge pointer drops slowly when the engine is sped up several times in secession this could indicate a clogged muffler An unblocked muffler will cause the gauge pointer to momentarily drop to zero When the gauge pointer remains at 12 IN Hg at any engine speed it could indicate late valve timing Test the choke by closing throttle all the way and starting the engine The gauge pointer should im
6. mediately rise to 22 IN Hg green zone If the gauge pointer stays around 3 to 6 IN Hg this may indicate a burnt riser tube or the failure of the throttle valve to close There could also be air leaks in the intake manifold system Page 5 Maintenance and Servicing Before each use Inspect the general condition of the Fuel Pump and Vacuum Gauge Tester Check for misalignment or binding of moving parts cracked or broken parts damaged Hoses loose connections and any other condition that may affect When storing Do not store fluid in the Cup Dispose of excess fluid properly according to federal state and local guidelines Store the Vacuum Pump in a clean dry location out of reach of children WARNING All maintenance service or repairs not listed in this manual are only to be attempted by a qualified service technician its safe operation If a problem occurs have the problem corrected before further use Do not use damaged equipment 2 When cleaning Do not clean the Vacuum Pump with cleaners or other solvents not intended for use with plastic components Use a clean cloth and if necessary a mild detergent Do not immerse the Vacuum Pump in any liquid Record Serial Number Here Note If product has no serial number record month and year of purchase instead PLEASE READ THE FOLLOWING CAREFULLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BU
7. n no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state PITTSBURGH 3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353
8. outlined in the vehicle manufacturer s service manual Every vehicle has specific measurement values for vacuum related readings It is beyond the scope of this manual to properly describe the correct procedure and test data for each vehicle 5 Before testing fuel system verify all connections are tight to eliminate leaking 6 Carbon monoxide is produced while a vehicle s engine is operating and is deadly in a closed environment Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the work area may not be vented properly Get fresh air immediately 7 Prior to using the Fuel Pump Tester make sure to place the vehicle s transmission in PARK if automatic or NEUTRAL if manual Then block the tires with chocks SKU 93547 10 11 12 13 14 15 16 17 For technical questions please call 1 800 444 3353 Be alert for hot engine parts to avoid accidental burns Avoid accidental fire and or explosion Do not smoke near engine fuel and battery components Do not allow gasoline to come into contact with hot manifolds or other engine components Do not change fittings with engine running Do not drive vehicle while under test After testing turn off engine and depressurize system before removing test components Place absorbing cloths around fittings before disconnecting Wipe up any spilled fuel and
9. set up or use of this product Fuel Pump Pressure Test 1 Page 4 Relieve the fuel line pressure from the vehicle fuel system Refer to the vehicle manufacturer s service manual for instructions on relieving pressure from the fuel line testing procedures and connection points and normal fuel pump pressure readings Disconnect the pump fuel output line at the pump Use the various Adapters included and Rubber Hose 2 to connect the Vacuum Pressure Gauge 1 directly to the fuel pump Use a small amount of pipe compound or pipe thread seal tape not supplied on the connection threads to prevent leaks Tighten using a wrench not supplied oo 10 11 WARNING Make sure all connections are tight to avoid fuel leaks Start the engine and leave at idle speed and immediately check for fuel leaks If fuel leaks are found turn engine off and fix leaks Read the Vacuum Pressure Gauge 1 for the correct pressure Turn off the engine The current reading should hold for one or two minutes before going down to zero Wrap a cloth around the hose connection point before relieving the pressure from the fuel line and remove testing components Reconnect vehicle s fuel line to the pump Wipe up any spilled fuel Dispose of fuel soaked rags in a fireproof container Start the engine and immediately check for leaks If fuel leaks are found turn engine off and fix leaks Clean and store
10. testing components Fuel Pump Vacuum Test 1 For technical questions please call 1 800 444 3353 With the engine off disconnect the fuel pump inlet line that comes from the fuel tank Have a towel ready to wipe up any spilled gasoline Connect the Vacuum Pressure Gauge 1 to the fuel pump inlet connector Use the Rubber Hose 2 and the various adapters that fit the pump inlet connector Do not kink Rubber Hose Do not allow air leaks Start the engine and immediately view the Vacuum Pressure Gauge 1 If the gauge pointer rises to 10 IN Hg the red zone before the pump SKU 93547 goes dry and the engines dies the fuel pump is working properly Turn ignition off and reconnect fuel line to the fuel pump Vacuum Testing 1 SKU 93547 With the engine off connect the Vacuum Pressure Gauge 1 as close as possible to the intake manifold Use the Rubber Hose 2 and the various adapters as needed Do not kink Rubber Hose Do not allow air leaks Engines with two intake manifolds have to be tested separately Start the engine and let it idle until the engine temperature reaches its normal operating temperature Adjust throttle butterfly valve and set idling speed to get a smooth engine idle Take vacuum reading from the Vacuum Pressure Gauge 1 Readings will vary depending on altitude At idle engine speed with a properly adjusted carburetor the gauge pointer will remain fixed b
11. to control Do not use a damaged tool Tag damaged tools Do not use until repaired Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tool s operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on another tool Tool service must be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel could result in a risk of injury When servicing a tool use only identical replacement parts Use of unauthorized parts or failure to follow maintenance instructions may create a risk of injury SKU 93547 Specific Safety Instructions 1 Maintain a safe working environment Keep the work area well lit Make sure there is adequate surrounding workspace Keep the work area free of obstructions grease oil trash and other debris Do not use this product in a damp or wet location 2 Maintain labels and nameplates on this product These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 3 Loosen gas cap and relieve fuel pump pressure before testing 4 Before use read and understand all warnings safety precautions and instructions as
Download Pdf Manuals
Related Search
Related Contents
CA95 / CA65 - Kawai Musical Instruments Manufacturing Co., Ltd. Quick Start Guide for the Shark® 100-S/200 ' Interface adapter for external signal CZ'—TA3iP Installation Manual 取扱説明書(保管用) ブーツ型 レンジフード separateur de batterie MD Building Products 01958 Instructions / Assembly : Free Download, Borrow, and Streaming : Internet Archive ASUS G751JT User's Manual Copyright © All rights reserved.
Failed to retrieve file