Home
Harbor Freight Tools 98342 User's Manual
Contents
1. repairs or alterations outside our facilities normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or con sequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the com plaint must accompany the merchandise If our inspection verifies the defect we will ei ther repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return re paired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state 3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353 Record Product s Serial Number Here Note If product has no serial n
2. connect ed to 115 V 60 Hz safety socket SKU 98342 For technical questions please call 1 800 444 3353 2 Make sure that the socket is suf ficiently secured and is in excellent condition 3 When the plug is inserted into the socket the pump will be on standby WARNING If the power cord or plug is damaged do not use the pump The power cord or plug may only be re paired by a certified electrician Areas of use 1 This pump is designed for use as a basement pump When installed in a shaft this pump provides some pro tection from basement flooding 2 This pump can also be used to trans fer water e g household farming plumbing OPERATION After reading these instructions con sider the following points before starting the pump 1 Verify that the pump rests on the floor of the shaft if it is not suspended by the handle 2 Verify that the delivery pipe is prop erly connected 3 Verify that the electrical connection is 115 V 60 Hz 4 Verify that the electrical socket is in good condition 5 Verify that water and moisture cannot get near the power supply socket 6 Verify that the pump is installed so as to prevent running dry Page 3 MAINTENANCE TO PREVENT AWARNING SERIOUS INJURY FROM ACCIDENTAL OPERATION Unplug the Pump from its electrical outlet before performing any inspection maintenance or cleaning procedures If the pump is moved during op eration fl
3. ER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO SKU 98342 For technical questions please call 1 800 444 3353 Page 5 PARTS LIST Part Description Qty 6 Cable Compaction Buckle _ 8 2 SKU 98342 For technical questions please call 1 800 444 3353 Page 6 ASSEMBLY DIAGRAM SKU 98342 For technical questions please call 1 800 444 3353 Page 7 LIMITED 1 YEAR 90 DAY WARRANTY Harbor Freight Tools Co makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine motor the belts if so equipped and the blades if so equipped are free of defects in materials and workmanship Har bor Freight Tools also warrants to the original purchaser for a period of one year from date of purchase that all other parts and components of the product are free from defects in materials and workmanship 90 days if used by a professional contractor or if used as rental equipment This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents
4. J PACIFIC HYDROSTAR 1 4 HP SUBMERSIBLE WATER PUMP Lere C3 98342 SET UP AND OPERATING INSTRUCTIONS Distributed exclusively by Harbor Freight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included For technical questions or replacement parts please call 1 800 444 3353 Before start up note the following 8 The pump can be connected to any shock proof plug which has been installed according to regulations The plug must have a supply voltage of 115 V at 60 Hz CAUTION This pump has been evaluated for use with water only AWARNING IMPORTANT For your own safety before starting to run the pump please have the following items checked by an expert 1 Risk of electric shock This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock connect only
5. d examine check valve installed backwards Pump won t start Check power connections and 1 Consult with an electrician or run circuits fuses Water level too low Allow water level to rise above 1 8 or move Pump to a lower location Filter and or impeller clogged 3 Remove filter Clean out dirt and debris from filter and impeller Then replace filter Defective motor Have a qualified service technician repair or replace Excessive noise or 1 Worn bearings Have a qualified service technician repair or vibration replace Debris in impeller Remove filter Clean impeller Then replace filter Discharge garden hose Clean Pump and discharge garden hose restricted Pump starts Water temperature too high Do not exceed temperatures above 95 and stops too Fahrenheit frequently Back flow of water from Install or inspect optional check valve discharge garden hose Follow all safety precautions whenever diagnosing or servicing the tool Disconnect power supply before service PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTUR
6. s SPECIFICATIONS P mp vplicatins Removes Clear Water Down to pape 1 8 of Surface Electrical 115 V 60 Hz 1 4 HP Requirements 2 6 A Start 2 5 A Run TBAWG X30 SIT Maximum Capacity 1400 GPH Approx 23 GPM Maximum Delivery Height 26 3 Ft 1 Pipe with 3 4 11 5 TPI Garden Hose Adapter Discharge Size Page 2 UNPACKING When unpacking check to make sure that the item is intact and undamaged If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible INSTALLATION The submersible motor pump must be installed in a stationary position with either a A fixed pipeline or b A flexible hose pipe Please note 1 Do not install the pump by suspend ing it unsupported from its delivery pipe or power cord The pump must be suspended from the handle or be placed on the bottom of the shaft To ensure that the pump works properly keep the bottom of the shaft free from sludge and dirt of all kinds 2 Ifthe water level sinks too low any sludge in the shaft will dry out and stop the pump from starting To help ensure the pump will start as re quired check the pump regularly with start up tests 3 The pump must be installed with an automatic float switch not included to prevent running dry Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be
7. to a properly grounded grounding type receptacle 2 Risk of electric shock This pump has not been investigated for use in swimming pool areas 3 The electrical connections must be protected from moisture 4 If there is danger of flooding the electrical connections must be taken to higher ground 5 Circulation of caustic fluids as well as the circulation of abrasive materi als must be avoided at all costs 6 The pump must be protected from frost 7 The pump must be protected from running dry SKU 98342 For technical questions please call 1 800 444 3353 Access by children should also be prevented with appropriate mea sures WARNING Handling the Power Cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health amp Safety Code 25249 5 et seq 10 The warnings precautions and in structions discussed in this instruction manual cannot cover all possible con ditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be supplied by the operator Fluid Type The Pump is designed for use with water with a maximum temperature of 95 F 35 C Do not use the pump for other fluids especially not fuels cleaning fluids or other chemical product
8. umber record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not avail able individually as replacement parts SKU 98342 For technical questions please call 1 800 444 3353 Page 8
9. ush it out with clean water after every use Quarterly Maintenance The below maintenance must be per formed at least once every 3 months under optimal conditions For frequent use or dirty areas more frequent maintenance is required 1 Clean sludge and debris from the bot tom of the shaft 2 Rinse the housing off with clean wa ter 3 Clean fibers from inside the pump housing with a pressure washer not included 4 Ifthe pump housing cannot be cleaned from the outside it must be thoroughly cleaned Make sure the power cord is unplugged before maintenance Dismantle the bottom part of the pump as follows SKU 98342 mpeLLer FIGURE B 14 FILTER 11 Remove the Filter 11 from the pump Case b Clean the impeller with clean water To prevent damage do not rest the pump on the impeller or pry against the impeller Reassemble in reverse order For technical questions please call 1 800 444 3353 Page 4 Troubleshooting Possible Causes Possible Solutions Pump runs but Filter and or impeller clogged 1 Remove filter Clean out dirt and debris from will not deliver any filter and impeller Then replace Filter water When starting the pump water 2 There must be at least 1 8 deep water for the height 1 8 falls below the Pump to operate properly minimum water level Low line voltage Consult with an electrician 4 Optional check valve stuck or 4 Remove an