Harbor Freight Tools 28 LED Work Light Product manual
Contents
1. any wet location matching outlets will reduce risk of electric shock 4 Do not obstruct walkways or 11 Do not abuse the cord Never use the cord common areas with the cord for carrying pulling or unplugging the Light Keep cord away from heat oil sharp edges 5 This product is not intended for use in a or moving parts Damaged or entangled residence or to be mounted in a cabinet cords increase the risk of electric shock This product is not suitable for recessed installation in ceilings or on buildings 12 Maintain the Light Check for breakage of parts and any other condition that may affect 6 Do not use the Light if the On Off Button does not the Light s operation If damaged have it turn it on and off Any Light that cannot be controlled repaired before use Many accidents are with the Button is dangerous and must be repaired caused by poorly maintained items 7 Wear ANSI approved goggles during setup and use 413 Maintain labels and nameplates on the Light These carry important safety information If Page 2 For technical questions please call 1 888 866 5797 Item 66274 14 15 16 unreadable or missing contact Harbor Freight Tools for a replacement Do not leave the Light unattended when it is plugged into an electrical outlet Turn off the Light and unplug it from its electrical outlet before leaving This product is not a toy Keep it out of reach of children People with pacemakers should consult their
2. durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty t
3. physician s before use Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure In addition people with pacemakers should e Avoid operating alone e Properly maintain and inspect to avoid electrical shock 17 18 e Any power cord must be properly grounded Ground Fault Circuit Interrupter GFCI should also be implemented it prevents sustained electrical shock WARNING Handling the cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health amp Safety Code 25249 5 et seq The warnings precautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be supplied by the operator A SAVE THESE INSTRUCTIONS luminar WORK Item 66274 For technical questions please call 1 888 866 5797 Page 3 AWARNING TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE CONNECTION Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded Do not modify the power cord plug provided with the Light Never remove the grounding prong from the plug Do not use the L
4. the Knob 3 of the Lamp Assembly 1 Operating Instructions Read the ENTIRE IMPORTANT SAFETY INSTRUCTIONS section at the beginning of this manual including all text under subheadings therein before setup or use of this product gt 1 Position the LED work light near the work 3 To prevent accidents disconnect the power Loosen Knob and adjust Lamp Assembly to supply after use Clean then store the direct the light beam Tighten the Knob Light indoors out of children s reach N Plug the Light into a grounded 120VAC electrical outlet Maintenance And Servicing Procedures not specifically explained in this manual must be performed only by a qualified technician AWARNING TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Make sure that the On Off Button is in the OFF position and unplug the tool from its electrical outlet before performing any procedure in this section TO PREVENT SERIOUS INJURY FROM LIGHT FAILURE Do not use damaged equipment If damage is noted have the problem corrected before further use BEFORE EACH USE inspect the general 2 AFTER USE allow Light to cool and then wipe condition of the light Check for external surfaces of the Light with a clean cloth loose hard Rie pe re AAWARNING If the supply cord of this misalignment or binding of moving parts light is damaged it must be replaced only damaged cord electrical wiring by a qualified service technician cracked or broken p
5. Owner s Manual amp Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future reference MODEL 66274 3 WATT 120 VOLT 28 BULB LED WORK LIGHT Visit our website at http www harborfreight com BEV Email our technical support at productsupport harborfreight com When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2008 by Harbor Freight Tools All rights reserved F gt No portion plies manual mo any artwork ned Se be reproduced in Read this material before using this product any shape or form without the express written consent of Harbor Freight Tools Failure to do so can result in serious injury Diagrams within this manual may not be drawn proportionally Due to continuing SAVE THIS MANUAL improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included luminar WORK WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messag
6. See Outlets for 2 Prong Plug 2 Double insulated tools may be used in either of the 120 volt outlets shown in the preceding Outlets for 2 Prong Plug illustration See Outlets for 2 Prong Plug 1 Tools marked Double Insulated do not require grounding They have a special double insulation Extension Cords 1 Grounded Lights require a three wire extension cord example a 14 gauge cord can carry a Double Insulated Lights can use either higher current than a 16 gauge cord a two or three wire extension cord 4 When using more than one extension cord to 2 As the distance from the supply outlet increases make up the total length make sure each cord you must use a heavier gauge extension cord contains at least the minimum wire size required Using extension cords with inadequately sized wire f causes a serious drop in voltage resulting in loss of 5 f you are using one extension cord for more than power and possible tool damage See Table A one tool add the nameplate amperes and use the sum to determine the required minimum cord size 3 The smaller the gauge number of the wire the greater the capacity of the cord For Page 4 For technical questions please call 1 888 866 5797 Item 66274 Dooe onen TABLE A RECOMMENDED Canada to indicate it is acceptable for outdoor use MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 VOLT 7 Make sure the extension cord is properly wired and in good electrical condition Alwa
7. arts and any other condition that may affect its safe operation Page 6 For technical questions please call 1 888 866 5797 Item 66274 PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List and Diagram Part Description Qty 1 LampAssembly 1 2 Bases i O t i 3 Knob A t i Record Serial Number Here Note Some parts are listed and shown for Note If light has no serial number record month illustration purposes only and are not available and year of purchase instead individually as replacement parts Item 66274 For technical questions please call 1 888 866 5797 Page 7 Limited 90 Day Warranty Harbor Freight Tools Co makes every effort to assure that its products meet high quality and
8. es that follow this symbol to avoid possible injury or death A DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury AWARN N G Indicates a hazardous situation which if not avoided could result in death or serious injury Indicates a hazardous situation which if not avoided ACAUTION could result in minor or moderate injury NOTICE CAUTION Addresses practices not related to personal injury INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of FIRE ELECTRIC SHOCK OR INJURY TO PERSONS 1 Do not operate the portable luminaire with a missing 8 Keep work area clean and well lit Cluttered or damaged guard or lamp containment barrier or dark areas invite accidents 2 Avoid electric shock Do not use with an extension 9 Do not operate the Light in explosive atmospheres cord near water or where water may accumulate such as in the presence of flammable liquids Keep lamp at least 16 feet 5m from pools gases or dust The Light generates sparks and spas Keep plugs and receptacles dry which may ignite the dust or fumes Use only on GFCl protected circuits Do not submerge the Light in water 10 The Light s plug must match the outlet Never modify the plug in any way Do not use any 3 The Light is not waterproof Use extreme adapter plugs with the Light Unmodified plugs and caution in
9. hen you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state luminar WORK 3491 Mission Oaks Blvd e PO Box 6009 Camarillo CA 93011 888 866 5797
10. ight if the power cord or plug is damaged If damaged have it repaired by a service facility before use If the plug will not fit the outlet have a proper outlet installed by a qualified electrician Grounded Lights Lights with Three Prong Plugs 1 Lights marked with Grounding Required have 3 The Light must be plugged into an appropriate outlet a three wire cord and a three prong grounding properly installed and grounded in accordance plug The plug must be connected to a properly with all codes and ordinances The plug and outlet grounded outlet If the Light should electrically should look like those in the preceding illustration malfunction or break down grounding provides See 3 Prong Plug and Outlet a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the grounding 8 system in the Light The green wire in the cord must be the only wire connected to the Light s grounding system and must never be attached to an electrically D live terminal See 3 Prong Plug and Outlet 3 Prong Plug and Outlet Double Insulated Lights Lights with Two Prong Plugs system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories Inc the Canadian 8 8 Standard Association and the National Electrical Code
11. ys replace NAMEPLATE EXTENSION CORD a damaged extension cord or have it repaired AMPERES LENGTH by a qualified electrician before using it at full load 8 Protect the extension cords from sharp objects 16 excessive heat and damp or wet areas Based on limiting the line voltage drop to five volts at 150 of the rated amperes Symbology NN WARNING marking concerning Risk Double Insulated OW of Eye Injury Wear ANSI approved safety goggles with side shields o Canadian Standards Association N Read the manial before set up and or use O Underwriters Laboratories Inc WARNING marking concerning Risk of Fire Volts Alternating Current ec WARNING marking concerning A Amperes Risk of Electric Shock 7 Properly connect power cord No Load Revolutions per Minute RPM to appropriate outlet Specifications l Electrical Rating 120VAC 60Hz 0 3A UL var S Light Strength 270 Lumens Intertek 4008835 luminar WORK Item 66274 For technical questions please call 1 888 866 5797 Page 5 Set Up Instructions Read the ENTIRE IMPORTANT SAFETY INSTRUCTIONS section at the beginning of this manual including all text under subheadings therein before setup or use of this product gt Initial Set Up Instructions Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual 1 Slide the Base 2 into the bottom 2 Secure with