Home

Harbor Freight Tools 1/6 HP Submersible Utility Pump 1350 GPH Product manual

image

Contents

1. proof plug which has been installed according to regulations The plug must have a supply voltage of 120 VAC at 60 Hz CAUTION This pump has been evaluated for use with water only AWARNING IMPORTANT For your own safety before starting to run the pump please have the following items checked by an expert 1 Risk of electric shock This pump is supplied with grounding conductor and grounding type attachment plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle 2 Risk of electric shock This pump has not been investigated for use in swimming pool areas 3 The electrical connections must be protected from moisture Do not submerge power cord connection 4 lf there is danger of flooding the electrical connections must be taken to higher ground 5 Circulation of caustic fluids as well as the circulation of abrasive materials must be avoided at all costs 6 The pump must be protected from frost 7 The pump must be protected from running dry 8 Access by children should also be prevented with appropriate measures 9 WARNING Handling the Power Cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health amp Safety Code 25249 5 et seq 10 People with pacemakers should consult t
2. BLY DIAGRAM Part Description Qty 5 IlScrew 8 Record Produc s Serial Number Here Note II product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts Page 6 For technical questions please call 1 888 866 5797 Item 68422 Limited 90 Day Warranty Harbor Freight Tools Co makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be return
3. Owner 5 Manual amp Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future reference ITEM 68422 PACIFICHYDROSTAR 1 6 HORSEPOWER SUBMERSIBLE UTILITY PUMP Visit our website at http www harborfreight com REV 14c Email our technical support at productsupport harborfreight com When unpacking make sure that the product is intact and undamaged If any parts are missing or broken AWARNING please call 1 888 866 5797 as soon as possible Copyright 2014 by Harbor Freight Tools All rights reserved z 2 No portion of this manual or any artwork contained herein may be reproduced in Read this material before using this product any shape or form without the express written consent of Harbor Freight Tools Failure to do so can result in serious injury Diagrams within this manual may not be drawn proportionally Due to continuing SAVE THIS MANUAL improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included w gt m lt Before start up note the following The pump can be connected to any shock
4. clay sand or gravel surfaces 3 Make sure the Pump s inlet openings near the suction base are free of debris 4 Avoid installing Pump in areas of extreme heat or cold Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to 120 VAC 60 Hz safety socket 2 Make sure that the socket is sufficiently secured and is in excellent condition 3 When the plug is inserted into the socket the pump will start operating Item 68422 WARNING If the power cord or plug is damaged do not use the pump The power cord or plug may only be repaired by a certified electrician Hose Connections 1 Use the included adaptor to connect a 5 8 or larger hose to the pump outlet using a step nipple and hose clamps not included 2 Route the hose to the desired discharge area The hose should be kept as short as possible with a minimum number of turns For best performance the max recommended hose length is 50 ft 3 To reduce vibration and noise a short section of rubber hose maybe be attached to the end of the discharge line with clamps Areas of use 1 This pump can be used to transfer water e g household farming plumbing After reading these instructions consider the following points before starting the pump 1 Verify that the pump rests on the floor of the shaft if it is not suspended by the handle 2 Verify that the delivery pipe is properl
5. clean water 3 Clean fibers from inside the pump housing with a clean cloth then store Pump in a dry and clean location away from children 4 Ifthe pump housing cannot be cleaned from the outside it must be thoroughly cleaned Unplug the power cord before maintenance Dismantle the bottom part of the pump as follows a Remove Screws 5 and Volute 4 b Clean the impeller with clean water c To prevent damage do not rest the pump on the impeller or pry against the impeller d Reassemble in reverse order PACIFICHYDROSTAR gt gt m gt gt 9 m Page 4 For technical questions please call 1 888 866 5797 ltem 68422 Troubleshooting Possible Causes Possible Solutions Pump runs but Filter clogged Clean out dirt and debris from filter will not deliver Impeller clogged Remove Volute Clean out dirt and debris any water from Impeller Replace Volute When starting the water There must be at least 1 2 deep water height falls below the minimum for the Pump to operate properly water level 1 2 Low line voltage Consult with an electrician Optional check valve stuck Remove and examine check valve or installed backwards Pump won t Filter clogged Clean out dirt and debris from filter start or run Impeller clogged Remove Volute Clean out dirt and debris from Impeller Replace Volute Defective motor Replace with new pump Excessive noise Wo
6. ed to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state PACIFICHYDROSTAR PAGIFICHYDROSTAR 3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 1 888 866 5797
7. heir physician s before use Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure 11 The warnings precautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be supplied by the operator Page 2 For technical questions please call 1 888 866 5797 Fluid Type The Pump is designed for use with water with a maximum temperature of 77 F 25 C Do not use the pump for other fluids especially not fuels cleaning fluids or other chemical products Specifications Electrical Requirements 120VAC 60Hz 2 2A 1 6 Horsepower Electric 10 IL Do not submerge beyond Power Cord Length power cord length Do not submerge power cord connection Maximum Flow Rate 1350 GPH Maximum Head Lift 23 ft Discharge Size 1 NPT Drains To 1 2 of surface US 252728 Installation The submersible pump must be installed with either a A fixed pipeline or b A flexible hose pipe Please note 1 Do not install the pump by suspending it unsupported from its delivery pipe or power cord The pump must be suspended from the handle or be placed on the bottom of the area 2 Make sure the Pump rests on flat level and solid foundation Do not operate it on earth
8. rn bearings Replace with new pump or vibration Debris in impeller Remove filter Clean impeller Then replace filter Discharge hose restricted Clean Pump and discharge hose Pump starts Water temperature too high Do not exceed 77 Fahrenheit water temperature and stops too Back flow of water from Install or inspect optional check valve frequently discharge hose Follow all safety precautions whenever diagnosing or servicing the tool Disconnect power supply before service PACIFICHYDROSTAR MAINTENANCE Item 68422 For technical questions please call 1 888 866 5797 Page 5 gt gt m gt Z 9 m PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO PARTS LIST AND ASSEM
9. y connected 3 Verify that the electrical connection is 120 VAC 60 Hz 4 Verify that the electrical socket is in good condition 5 Verify that water and moisture cannot get near the power supply socket or power cord connection 6 Verify that the pump is installed so as to prevent running dry NOTE The Pump will remove water down to 1 2 Unplug the Pump once 1 2 water level is reached 7 Ifthe pump is not going to be monitored CONSTANTLY and disconnected when the water level drops it must be installed with an automatic float switch not included to shut it off before it runs dry CAUTION Do not run the Pump dry Doing so will increase wear on the unit and can lead to seal damage 8 Plug power cord into an outlet protected by a CLCI Z 5 4 ou oO PACIFICHYDROSTAR ltem 68422 For technical questions please call 1 888 866 5797 Page 3 Maintenance AWARNING TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Unplug the Pump from its electrical outlet before performing any inspection maintenance or cleaning procedures If the pump is moved during operation flush it out with clean water after every use Quarterly Maintenance The below maintenance must be performed at least once every 3 months under optimal conditions For frequent use or dirty areas more frequent maintenance is required 1 Clean sludge and debris from the base of the Pump 2 Rinse the housing off with