Home

Halsey Taylor HRFG - SER*A User's Manual

image

Contents

1. FINI HH TIIHO SEM 191100 HHTIHO 131I1NO HH TIIHO FE OU SIIIENgOL OL y318gn9 OL HRFG ER A HRFG SR A HRFG SER A PARTS LIST LK464 Drain 15005C Retaining Nut 40038C Strainer 40619C Tailpipe Ferrule 45662C Push Button 45738C Push Button Sleeve 50986C Regulator Holder 51544C Bubbler 61313C Regulator 70022C Setscrew 6 32 x 31 112627543890 Scr 10 24 x 1 2 PH TR HD Z 55996C Strainer 56087C Push Button Extension 27201C Bottom Cover Plate Short 27658C Bottom Cover Plate Extended 26839C Back Panel HRF SER 26837C Back Panel HRF ER 26835C Back Panel HRF SR 40045C Hex Nut 75554C Insert Threaded 70012C Bubbler Locknut 27026C Lower Panel HRF SER 26833C Lower Panel HRF ER 70745C Union 3 8 x 1 4 70870C Union 3 8 70852C Tee 3 8 55969C Fountain Galaxy Gray HRFG S 56053C Fountain Galaxy Gray HRFG E 56025C Fountain Black HRFG S 56056C Fountain Black HRFG E 100322740560 Gasket Black 66399C Tube Assy Reg to Bubbler 45736C Nut Regulator Mounting gt TROUBLE SHOOTING amp MAINTENANCE Orifice Assy Mineral deposits on orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file not over 1 8 diameter or small diameter wire CAUTION DO NOT fi
2. Cleaners left standing on the fountain surface can dull the surface finish Be certain to rinse all cleaning agents completely and polish with a soft cloth Harsh abrasive cleaners are not required and should not be used Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple scratches and stains Cigarette burns can normally be removed without noticeable effect Deeper scratches or gouges can be corrected with fine grit sandpaper 240 grit then 400 grit ora green Scotchbrite pad To maintain or regain luster and make cleaning easier periodic applications of automobile wax or like products will keep the finish looking like new 97716C Rev A 5 02 PAGE 4 HRFG ER A HRFG SR A HRFG SER A 3 8 O D UNPLATED COPPER TUBE CONNECT 1 4 O D TUBE COLD WATER SUPPLY WATER INLET BUILDING WATER INLET TO COOLER SERVICE STOP a NOTE WATERFLOW DIRECTION NOT FURNISHED OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET TUBE TOATTACH IN POSITION TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE HRFG ER A HRFG SR A HRFG SER A tee BASIN 16 2 FIG 6 TOP VIEW HRFG ER A HRFG SR A HRFG SER A ONILNOY 8 944H ONILNOY FANL HS 43 914H a LIN HH TIIHO
3. HRFG ER A HRFG SR A HRFG SER A Halsey Taylor Owners Manual Refrigerated Marblyte Fountains with Back Panel HRFG ER HRFG SR HRFG SER Installer To assure you install this model easily and correctly PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING ELECTRICAL AND OTHER APPLICABLE CODES After installation leave these instruc tions inside the fountain for future reference IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM 97716C Rev A 5 02 HRFG ER A HRFG SR A HRFG SER A HRFG ER SR ROUGH IN Up WALL LINE 9 3 8 238mm BACK WALL LINE C 39 1 2 I003mm IHRFG SRI es ECTRICA 947mm ET HRFG SR 27 686m HRFG ADA REQUIREMENT FINI
4. SHED FLOOR LEGEND A 3 8 TUBE WATER OUTLET B 3 8 0 D TUBE WATER INLET 1 1 4 WASTE TUBE NOT INCLUDED FIG 1 97716C Rev A 5 02 PAGE 2 HRFG ER A HRFG SR A SER A HRFG SER ROUGH IN 3 1 8 1 1 8 29mm e Y 18 3 4 476mm 5 5 8 143mm WALL LINE X N 3 3 9 3 8 238 T 18 3 16 462mm BACK WALL LINE 13 7 8 352mm N IN 37 1 4 33 1 2 947mm ELECTRICAL 851mm INLET 27 39 1 2 686mm 1003mm ADA REQUIREMENT 31 2 89mm 31 1 4 794mm X FINISHED FLOOR 1 25mm LEGEND 3 8 O D TUBE WATER OUTLET B 3 8 O D TUBE WATER INLET 1 1 4 O D WASTE TUBE NOT INCLUDED FIG 2 PAGE 3 97716C Rev A 5 02 HRFG ER A HRFG SR A HRFG SER A INSTALLATION INSTRUCTIONS 1 Install remote chiller Remove front panel of chiller Remove and discard cardboard inner pack from be tween compressor and side panel Slide chiller onto the shelf and position it to the left within the guides on the shelf NOTE Building construction must allow for adequate air flow on both sides top and back of chiller A minimum of 4 102mm on both sides and top is required See chiller instructions for additional instructions 2 Make water supply connections Attach an unplated copper water inlet line and a service stop not provided to the chiller Inlet port is marked on the chille
5. ate on 20 105 PSIG supply line pressure If inlet pressure is above 105 PSIG a pressure regulator must be installed in the supply line Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty 8 Make electrical connections to the chiller See chiller instructions 9 Check stream height from bubbler Stream height is factory set at 45 50 PSI If supply pressure varies greatly from this remove items 5 amp 13 See Figure 6 Page 6 by loosening set screw item 10 and adjust the screw on regulator item 9 Clockwise adjustment will raise stream height and counter clockwise adjustment will lower stream height For best adjustment stream height should be approximately 1 1 2 38mm above the bubbler guard See Figure 5 Page 5 10 Mount lower panel Loosen the 2 10 24 x 5 8 16mm screws at frame bottom lip Slide upper tongue of lower panel under lower edge of already installed upper panel Tighten previously loosened screws securely 11 Replace bottom access panel to fountain basin using screws provided Tighten securely Care and Maintenance of Halsey Taylor Marblyte Fountains Marblyte provides an exremely durable nonporous surface which resists staining Care is very simple Routine cleaning with a soft sponge or cloth or with water or non abrasive aerosol foam cleaner is all that is normally needed to give many years of trouble free service
6. le or cut orifice material Stream Regulator If orifice is free of material deposits regulate flow as instructions on page 4 Step 9 If replace ment is necessary see parts list for correct regulator part number Actuation of Quick Connect Water Fittings Cooler is provided with lead free connectors which utilize an o ring Water seal To remove tubing from the fitting relieve water pressure push in on the gray collar while pulling on the tubing see Fig 4 Page 5 To insert tubing push tube straight into fitting until it reaches a positive stop approximately 3 4 2222 CAMDEN COURT OAK BROOK IL 60523 630 574 3500 N FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1 800 323 0620 97716C Rev A 5 02 PAGE 8
7. r 3 8 O D copper tube Bend the copper tube provided at an appropriate length from chiller to opening in frame Install a 3 8 O D tube tee fitting pro vided on the marked chiller outlet port Turn on the water supply and flush the line thoroughly 3 Hang the upper panel on the mounting frame hanger Align holes in the panel with the holes in the mounting frame Be sure that panel is engaged with hanger at top of frame before releasing it 4 Install fountain Remove access cover plate on underside of fountains and save the screws Mount the fountains to the upper panel and the wall frame with 4 5 16 x 1 1 4 82mm long bolts washers and nuts Tighten securely but do not overtighten Over tightening will crack the Marblyte Fountain NOTE The short fountain should be mounted to the upper left hand side of the panel 5 Remove elbow from end of p trap and attach it to drain tube Re attach elbow to p trap and cut waste tube to required length using plumbing hardware and trap as a guide 6 Make connection between remote chiller outlet tube and fountain strainer Insert the water inlet line into inlet side of strainer by pushing it in until it reaches a positive stop approximately 3 4 19mm Turn on water supply and check for leaks Newly installed water supply line should be insulated after leak check is completed DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O RINGS MAY RESULT 7 These products are designed to oper