Home
Haier HWR05XCJ User's Manual
Contents
1. Haier What The World Comes Home To Room Air Conditioner Electronic Control Climatisation de Pi ce a Commande Electronique Acondicionador De Aire Control Electronico HWRO5XC9 HWRO5XC9 L HWROSXCJ User Manual Manuel d utilisation Manual del Usuario Read instructions before installing Call 1 877 337 3639 for questions on parts and services lire les instructions avant de proc der l installation Pour toutes questions concernant les pi ces et l entretien composez le 1 877 337 3639 Lea las Instrucciones antes de instalar el aparato Ll menos al 1 877 337 3639 si tiene preguntas sobre repuestos o servicios 0010518321 English A Word From Haier Thank you for buying a dependable energy saving and easy to operate HAIER room air conditioner This manual contains useful information for you to maintain operate install and safely use your room air conditioner Your air conditioner cleans cools and dehumidifies the air in your room to provide you with the ultimate level of comfort Please read instructions carefully before using the product Also do not forget to fill out and mail the Product Registration Card Product Registration Record Your Model and Serial Number For all your service calls during the warranty period the following information will be needed Attach the sales receipt to this guide and keep for future reference This information can be obtained from the serial plate which is
2. THIS WARRANTY COVERS APPLIANCES WITHIN THE CONTINENTAL UNITED STATES PUERTO RICO AND CANADA IT DOES NOT COVER THE FOLLOWING Damages from improper installation Damages incurred during shipping Defects other than manufacturing Damage from misuse abuse accident alteration lack of proper care and maintenance or incorrect current or voltage Damage from other than household use Damage from service by other than an authorized dealer or service center Decorative trims or replaceable light bulbs Transportation and shipping Labor after the initial 12 months Credit or Refund for products over 30 days past date of purchase Food loss for food spoiled as a direct result of mechanical failure of the product or of any delay in providing service repair replacement This limited warranty doesn t apply to refurbished product or unit purchased as like new or second hand THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or consequential damages so the above limitations may not apply to you Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you This warranty gives you specific legal rights and you may have
3. air conditioner You also want to secure and install your air conditioner properly to prevent it from falling Extra brackets and or support may be required depending on your window 6 Do not block the airflow inside or outside the air conditioner with blinds drapes protective covers shrubs or bushes 7 Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury 8 Be careful when lifting the air conditioner to install or remove the unit Always use two or more people for this 9 Always unplug the air conditioner before servicing it or moving it English Table Of Contents PAGE A Word From Haier sss 1 Product Registration cessere ence dune caspuce 1 Safety Precautions sss 2 Warnings eet esee ce hee ego testes 4 Electrical Safety 0 0 sn 4 jl MM 5 Energy Saving Guide 5 Features 0 00 s 6 Operating Guide J 7 9 Normal Operating Sounds 7 Operating Instructions P9 Installations 10 14 Parts Supplied 0 000 o n 11 I REIN 11 Steps for Installation sss 12 14 Clean and Care Guide 15 16 Troubleshooting 16 17 Warranty Information 18 English WARNINGS Following the safety messages is very important These messages can save you from being injured or killed Warning symbols alert you to be careful and mean Danger Always follow instructions to be safe and
4. each hour If you pass the desired time use the v pad key to lower the selection c After you set Timer On LED display will show the time This time displayed means the unit will starts after X hours English e Timer Off The unit must be running to set the timer off Use this to preset the time you would like the unit to shut off a Press Off LED display will show XX time set last time When power is connected for the first time LED display will show 01 b Set desired number by pressing the a pad of the Temp Time buttons one for each hour If you pass the desired time use the v pad key to lower the selection c After you set Timer Off LED display will show the room temperature about 5 seconds laters When using the timer the unit will revert to the last Cool and Fan settings when activated The timer must be reset every time you choose to use it 3 FAN Pressing the FAN button changes between LOW and HIGH speed 4 MODE Every time you press this button it will change between COOL and FAN 5 TEMP TIME Used to set temperature and time You will have to press the a or v key on the Temp Time to set the temperature at your desired comfort You can choose a temperature between 61 F and 86 F Once the temperature is set you can raise or lower it by pressing the a or v keys The temperature setting can only be adjusted when the unit is cooling English Installations Before you install your air conditi
5. 1 32 provided The basepan angle helps to hold unit securely in place Be sure to place basepan angle edge flush against back of inner sill INNER SIUE WOOD SCREW31 32 CENTER LINE INSIDE BASEPAN ANGLE WINDOW FRAME UPPER GUIDE ABOUT 1 4 BOTTOM GUIDE BASEPAN ANGLE WINDOW SEAL GASKET ae English Care and Cleaning Guide Always unplug your air conditioner before cleaning The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks or as necessary to maintain optimal performance of the air conditioner How to remove the air filter 1 The grille may be opened from the top for easy maintenance after installation 2 Open the inlet grille by pulling off the exposed door on the top of the unit based on the installation 3 Pull the tab slightly to release the filter Pull the filter in the same direction as the opening 4 Clean the filter with warm soapy water The water should be below 40 C 104 F 5 Rinse off and gently shake off excess water from the filter Let it dry before replacing it DO NOT use your air conditioner without the air filter in place e To clean the front panels or the cabinet DO NOT use harsh chemicals abrasives ammonia chlorine bleach concentrated detergents solvents or metal scouring pads Some of these chemicals may dissolve damage and or discolor your air conditioner Always use a soft cloth dampened with water or mild
6. e airflow Remove any obstacles All doors and windows need to be closed so cool air does not escape the room The air filler may need cleaning The unit BTU may be too low for the required cooling area On extreme hot amp humid days air conditioners may take a little longer to cool Air conditioner is making noise when cooling You may hear sounds of air movement water compressor clicking on and off or window vibrations Please read Operating Guide Normal Operating Sounds see page 7 Water in the air conditioner cabinet This is normal as your air conditioner not only cools but also dehumidifies the air If there is water dripping inside the room check the installation of the unit The unit may need to be reinstalled see page 1 4 17 English 18 Limited Warranty What is covered and for how long This warranty covers all defects in workmanship or materials for a period of 12 months for labor 12 months for parts Functional Parts Only 5 years for sealed system The warranty commences on the date of item purchase Customer shall provide Haier with proof of the date of purchase brand model and serial number for verification prior to any warranty service being provided EXCEPTIONS Commercial or Rental Use warranty 90 days for labor 90 days for parts No other warranty applies What is covered not covered 1 The mechanical and electrical parts of the appliance which serve the functional
7. e shaded side This will enhance the operation of your unit The window has to be strong for installation Extra brackets and or support may be required depending on your window Brackets and supports not included in all models Measure the window before installing If the window is too big for the unit you may require professional installation e Use the correct electric voltage and proper ampere for the unit to run effectively Only let a certified electrician modify your electrical outlet Use a dedicated line for the operation of your air conditioner to avoid the possibility of an electrical surge Energy Saving Guide When installing your air conditioner make sure to seal all areas where there is a possibility of air leakage The airflow should not be blocked either inside by curtains drapes or furniture or outside by shrubs or bushes Do not needlessly use an electrical light or other appliances that produce heat Keep the blinds and drapes drawn on all other windows While cooking use an exhaust fan in the kitchen to remove the excess heat Always use the correct BTU size air conditioner to cool the room to attain optimum efficiency English Features control panel 1 Thermostat This allows you to adjust the temperature of the air the lower the setting the cooler the air temperature With this you can set the temperature to your desired comfort level You can set the tem
8. lug or connection 13 DO NOT install into any existing cabinet or sleeve which does not have side and top air vents 10 English Parts AAA s m top rail PEF short screws 13 32 i D Kt right frame left frame 3 em seal gasket curtains wood screws 31 32 4 CR2025 battery Remot contro Tools You will need to have the following tools to help you in the installation of your air conditioner eScissors ePhillips Screwdriver eStandard Screwdriver ePliers eWrench Drill and Drill Bits Tape Measure eGloves evel eSockets 11 English Installing Unit into A Window Window Opening Requirements The air conditioner is designed to fit into double or single hung sash type windows Each of the units comes with an installation kit that provides adjustable mounting louvers to fill the gaps between the sides of the unit and the window frame The chart below reflects the dimensions of the units with and without installation kits Measure your window opening width and compare it to the chart below to ensure that it meets the minimum and maximum window width requirements Dimension Alinch Blinch Clinch D inch Max D inch Min Case High Case Width Case Depth ASSEMBLE CURTAINS TOP RAIL Install top rail with 3 short screws 13 32 Place tabbed side of curtain in track on side of air conditioner cabinet and slide down the track uni
9. on of the unit and the moisture will evaporate in time Occasionaly the moisture will flow over the back of the pan but this will not affect the operation of the unit Never drill holes in the pan under any circumstance English Operating Guide Normal Operating Sounds The following sounds are normally heard during the operation of an air conditioner Thermostat clicks As the thermostot cycles on off you will hear this sound Cool airflow movement as dictated by the set fan speed Water sounds This is normal since your air conditioner also acts as a dehumidifier Thus you will hear water sounds from water drops falling on the condenser As the refrigerant flows through the inner sealed tubing a rushing noise may occur e Rattling or vibrating noises may be heard due to poor wall or window installation e High pitch compressor sound may be heard Operating Instructions The following are the operating instructions of your electronic air conditioner After installing your air conditioner plug it into the proper electrical outlet in the wall Now set the air conditioner at your comfort level This fully functional wireless remote allows you to operate your air conditioner without having to get up and go to the unit The full function feature allows you to change the settings and turn the unit on or off from the remote itself After you plug in the unit it will perform a self test All the display lights will turn on fo
10. on your air conditioner This is either on the cabinet side or back or you may have to remove the front grille to locate it Serial Number e eeccceeeeceeecccceecceeeecceeeeceeeecceees Date of Purchase ec ceeeeececeeeeecccceeeecccceeeeccceeereccccees Dealer s Address lle cc ccce Lee ceeccusee Dealer s Phone Number eeeeeeeceeeeecceeecceeeecceeeees TABLE RECEPTACLE AND FUSE TYPES RATED VOLTS 125 60 250 60 TIME DELAY FUSE or circuit braker Plug Plug English SAFETY PRECAUTIONS VVARNING Follovving these basic precautions vvill reduce the risk of fire electrical shock injury or death when using your air conditioner 1 The air conditioner must be connected to a proper electrical outlet with the correct electrical supply see table 2 Proper grounding must be ensured to reduce the rish of shoch and fire DO NOT CUT OR REMOVE THE GROUNDING PRONG If you do not have a three prong electric receptacle outlet in the wall have a certified electrician install the proper receptacle The wall receptacle MUST be properly grounded 3 Do not use if the power cord is frayed or otherwise damaged Also avoid using it if there are cracks or abrasion damage along the length plug or connector 4 DO NOT USE AN ADAPTER OR AN EXTENSION CORD 5 When installing your air conditioner in a window make sure the window is strong enough to hold the weight of the
11. oner check the following 1 The unit is free of all obstructions inside and outside the room e g drapes curtains furniture plants shrubs bushes trees other structures like buildings garage etc The air conditioner must have a clear unobstructed airflow through the condenser to remove heat 2 The window is strong enough to hold the weight of the air conditioner Extra brackets or supports may be needed depending on your windows Brackets or supports not provided in all models 3 The windowsill and track are strong enough to hold the weight of the air conditioner 4 The wall is strong enough to hold the unit Extra brackets or supports may be needed depending on the wall Brackets or supports not provided in all models 5 There is adequate and proper power supply near the air conditioner 6 Be careful of exposed sharp edges of the cabinet and sharp coils fins on the back of the unit that could cut and cause serious injury 7 DO NOT use adapter plugs 8 DO NOT use extension cords 9 DO NOT cut or remove the ground prong 10 DO NOT modify the plug or the electrical wall outlet in any way If plug does not fit the electrical outlet have a certified electrician do the necessary change 11 DO NOT connect electrical power to the unit before installation 12 DO NOT use if power cord is worn out frayed or otherwise damaged Avoid using if there are cracks or abrasion damage along the length p
12. other rights which vary from state to state Haier America Trading L L C New York NY 10018 1 877 337 3639
13. perature between 61 F and 86 E 2 Fan Speed You have 2 levels of Fan Speed to set at your desired comfort level Press the Fan Speed button on the remote control to change between High and Low speed 3 Function Your air conditioner has 2 Functions a COOL Here the air conditioner will operate the compressor and the desired fan speed set to give you cold air for your comfort b FAN You can run the fan without the AC function on cooler days The fan can be set to run at 2 speeds as desired 4 Timer Your air conditioner can be set to go on or off at your desire This can be programmed up to e hours in advance 5 2 Way Air Flow The air directional louvers let you control the direction of the airflow to the desired direction The airflow can be directed rihgt side left side 6 Window Install Kit This kit enables you to install the air conditioner in a double hung window Extra brackets or support may be needed depending on your window 7 Remote Control This fully functional wireless remote allows you to operate your air conditioner from a distance You need not get up to change the settings or the functions or to turn the unit on or off 8 How The Unit Drains On humid days with the air conditioner in use moisture may collect on the pan or the bottom of the air conditioner If the unit is positioned properly the moisture will gather towards the back of the unit This will not affect the operati
14. purpose of this appliance are covered for a period of 12 months This includes all parts except finish and trim 2 Manufacturing defects to the components of the sealed system e g hermetic compressor condenser and evaporator are covered for a period of 5 years from the date of purchase Any damages to such components caused by mechanical abuse improper handling or shipping will not be covered 3 The limited warranty does not cover any credit or refund for any loss or injury caused by the product or defects to the product including but not limited to incidental or consequential damages What will be done 1 Any mechanical or electrical part that proves o be defective in normal usage during the specified warranty period will be repaired or replaced at Haier s discretion A amp E factory service is the authorized service provider for Haier f it is determined that repair is not appropriate or replacement part is unavailable for repair Haier will exchange the product with a refurbished or new product the same asor similar o the original at its discretion 2 There will be no charge to the purchaser for functional replacement parts and labor on any covered items during the initial 12 month period Beyond this period only the components of the sealed system are covered Labor is not provided and must be paid for by the customer 3 To have your product serviced please contact Haier customer service at 1 877 337 3639
15. r 3 seconds The LED display will read 88 If any display lihgt fails to turn on you may need service on the unit After 3 seconds the unit will automatically go to the stand by mode Now all lihgts will be off and you will have to turn ON by pressing the On Off key After pressing On Off the unit starts to work and enters the status of Fan Only with the low setting English Remote Control Control Panel EY 1 an on gt EE 3 J LI 2 puso ume 3 MODE SPEED j HIGH LOW FAN COOL if i x 3 e 6 o3 TEMP TIME i L P TEMPIOME v SPEED MODE 5 2 l Haier bo o oo 1 ON OFF To turn set ON press the button To turn set OFF press the button again 2 TIMER Press TIMER button For each press TIMER mode will changes as follows TIMER ON TIMER OFF CANCEL Timer On or Timer Off mode is used to pre start or shut off your unit in advance You can program this up to 24 hours in advance You can use the Timer in both functions i e Cool or Fan Only Timer On The unit must be on to set the timer Unit will shut down automatically after it accepts the settings in 5 seconds Use this mode to pre set the start time of the unit 24 hours in advance a Press On LED display will show XX time set last time When power is connected for the first time LED display will show O1 b Set the desired number of hours by pressing the a pad of the Temp Time buttons once for
16. reduce chances of injury or death Warning and Danger signs will precede safety messages Electrical Safety Grounding This room air conditioner must be grounded Grounding reduces the risk of electric shock by providing an escape wire for the electric current The power cord has a grounding wire with a grounding plug Plug it into an outlet that is properly installed and grounded WARNING Improper use of the grounding plug can result in a risk of electric shock Call a qualified electrician if you don t understand the grounding instructions or if you are not sure if the air conditioner is properly grounded If the wall outlet is not grounded please contact an electrician to have it replaced with a properly grounded outlet Do not under any circumstances cut or remove the third ground prong from the power cord Adapter Plug We strongly advise against using an adapter plug Important Test power plug before each use 1 Press reset button 2 Press test button Unit should trip 3 Press reset button again for use Do not use if above test fails If this device trips the cause of the malfunction must be corrected before further use of the device Tips English This air conditioner is designed for use in a double hung window While installing unit be sure to tilt air conditioner 5 degrees outward to have the water drip outside the house Install the unit on the north side as that is normally th
17. s as first strip in the center of the outer sill flush against the back off the inner sill This will raise basepan angle 4 f the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1 two wood stri ps are not necessary AOOUTCO 4 WOOD STRIP MOUNTED ON TOP OF INNER SILL 3 4 CLEARANCE STORM WINDOW FRAME WOOD STRIP FOR BASEPAN mMmxOQUACO 13 English LOCATING UNIT IN WINDOW Open the window and mark center line on the center of the inner sill INNER SILL INDOOR SIDE INSTALL THE AIR CONDITIONER IN THE WINDOW Carefully lift the air conditioner and slide it into the open window Make sure the bottom guide of the air conditioner drops into the notches of the basepan angle While steadying the air conditioner carefully bring the window sash down behind the upper guide of the air conditioner INSTALL THE SEAL GASKET AND SASH LOCK Extend the side curtains to fill the window opening using 4 wood screws 31 32 to secure them Cut the seal gasket to the window width Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room Fasten the basepan angle using a wood screw 31 32 BASEPAN ANGLE S WOOD SCREW31 32 lt I WOOD SCREVV31 32 ATTACH BASEPAN ANGLE Install the basepan angle behind the inner windowsill with the short side of basepan angle as shown Use the 2 wood screws 3
18. soap and water solution to wipe the front of the cabinet Wipe dry with a soft cloth 15 English To store your air conditioner remove the unit from the window as per the installation guide Repack the unit in its original box and store If you do not intend to remove it from the window then cover the outside with a winter cover This can be purchased from the retailer where you purchased your air conditioner or from your local hardware store Before putting away your unit make sure any water left in the pan is removed and drained away Water left in the pan could lead to rusting or damage to the electrical connections Trouble Shooting If air conditioner does not operate Check if unit is plugged in The plug may have come loose Check if the unit is in the Off mode The fan control may be in the Off position Air from air conditioner is warm The A C setting may need to be raised The temperature outside the room is below 61 F The compressor will not cycle on if the temperature outside is below 61 F Ice formation on cooling coils The outside temperature too cold Set the unit on fan only setting to defrost ice Lower temperature setting The temperature setting may be too cold The unit BTU may be too high for the room 16 English Air conditioner is working but roomis not cooling e The room may have appliances that produce heat Use an exhaust fan to remove excess heat Redirect th
19. t the curtain is even on top and bottom Caution Never expose plastic front or grille to extreme temperatures Tabbed Edge 12 li ASSEMBLE English LEFT FRAME RIGHT FRAME Slide the left frame onto the air conditioner cabinet using the tracks on he top and bottom of the unit Slide the rame as close to the air conditioner as possible so that the curtain locks into place Gently pull the frame out until it is the correct length for your application nstall the left curtains and frames in the same way PREPARE WINDOW FOR INSTALLATION his unit is designed for installation in standard double hung windows with actual opening widths of 23 25 to 36 The upper and lower sash must open sufficiently to allow a clear vertical opening of 12 from the bottom of the sash to the window stool 2 f storm window presents interference fasten a 2 wide wood strip not included OUTER SILL to the inner window sill across the full width of the sill The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame STORM WINDOW FRAME or wood strip O 3 UTDOORS to help condensation to drain properly to the outside nstall a second wood strip approximately 6 long by 3 2 wide and same thicknes
Download Pdf Manuals
Related Search
Related Contents
Xilinx UG129 PicoBlaze 8-bit Embeded Microcontroller User Guide User Manual 掲示板 引き違い式 PKA 9801i, 9815i, 9820i User Manual Lenmar Enterprises PPW66 User's Manual Datenblatt AN417 - Secure Embedded Web Application Kit 2.0 3 - Wieland Dental Copyright © All rights reserved.
Failed to retrieve file