Home

Haier HW-12CV03 User's Manual

image

Contents

1. moving it When dirt accumulates on air filter air circulation will be blocked which causes poor cooling It is advisable to clean air filter every two weeks for longer operation Removal of air filter 1 Loose the air inlet by pushing PUSH at both sides of air inlet 2 Open the air inlet 3 Remove the air filter Air filter cleaning 1 Gently flap the dirt off the air filter 2 Carefully wash air filter in warm water below 40 C To obtain better cleaning effect soap water or neutral detergent may be used 3 Flush air filter carefully with clean water after removing dirt Let it dry completely Installation of filter 1 Replacing the air filter 2 Push the air inlet marked with PUSH until you hear a click Maintenance Disposal of condensate 1 The drain hole on the bottom of the air conditioner will be clogged by a rubber stopper to make the condensate in the bottom tray be spattered onto the condensation to raise efficiency of heat exchange If the spattering sound disturbs you you can adopt the method illustrated below Condensate runs out from the drain hole on the back of the unit 2 Remove the rubber stopper from the drain hole on the bottom in order to make the condensate run out In this method the efficiency of air conditioner will be slightly lower
2. COOL HI COOL HI FAN aha 4 TERMINAL BLOCK TERMINAL BLOCK R RED OR ORANGE B BLACK Y YELLOW BL BLUE BR BROWN NOTE BECAUSE OF DIFFERENT COMPRESSOR Y G YELLOW GREEN THE DOTTED PART MAY NOT BE USED Circulation Dehumidificati Di i Capacity W Power w Current A Airflow mih Cspacti HW 09CV03 2600 980 5 0 330 1 2 605X560X405 36Kg Yes HW 12CV03 3500 1300 6 3 380 1 5 605 560 405 42Kg Yes Haier THERMOCOOL Haier 1HERMOCOOL produce high quality air conditioners which are strong reliable elegantly styled yet practical and long lasting for the most demanding tropical climate and conditions Haier IHERMOCOOL new generation air conditioners are conveni to use highly efficient energy saving and are built for quiet running to withstand voltage flunctuations unique Haier THERMOCOOL 12MONTH GUARANTEE gives you peace mind and assured satisfaction from the moment of purchese The 12 MONTH GUARANTEE covers Free parts replacement under warranty Free repairs under warranty With 3 years warranty on all air conditioner compressors you have peace of mind from the date of purchase Unique Haier 1HERMOCOOL NATIONWIDE SALES AND SERVICE NETWORK offers you fast reliable service and replacement spare parts which will normally be avaiable for many years Sales and service is available in ILUPEJU IBADAN BENIN WARRI
3. PORT HARCOURT ABA ENUGU ONITSHA KADUNA KANO JOS MAIDUGURI ABUJA Contact TPZ or your local Haier THERMOCOOL distributor for information Haier 1HERMOCOOL reserves the right to amend specifications without notice as part of its continuous improvement programme Haier IHERMOCOOL is registered trademark HPZ Ltd Haier IHERMOCOOL sales office 45 47 Town Planning Way llupeju PM B 21132 Ikeja Lagos Nigeria TEL 234 0 1 4973460 8 Fax 234 0 1 4962076 E mail sales hpz com ng
4. Problems may occur if unit is installed in the following places Place where oil exists in the air including engine oil or seaside with salt breeze blowing and hot spring area with sulphureous gas in the air Trouble Shooting Phenomenon Check the unit Resolution Is plug firmly inserted Doesn t work Does fuse get burned Is there power Readjust power supply or replace fuse Is thermostat switch wrongly adjusted Readjust the thermostat Is direct sunlight in the room Use curtain or blind Is mode selection switch set to Hi fan or Lo fan No cool air or Shut doors and windows Is door or window left poor cooling open Are there any obstacles blocking air inlet and Remove the obstacles outlet Is there too much heat Remove the heat source in the room source Is air filter clogged Clean it If problems can not be solved please pull out power plug and contact your dealer Installation instruction Selection of the installation position 1 Select position where the structure is firm 2 Select position where the air inlet and outlet are smooth without obstacles 3 Select position where the cooled air can be blown to every corner 4 Select position where there s no direct sunlight If the sunlight is inevitable sun shading device is required 5 Select position where the outdoor airflow will not influence the neighbors 6 Select position where the drainage is smooth 7 Select posi
5. speed blowing out gentle air 5 When set to OFF air conditioner stops running OFF When mode selection switch is shifted to HI fan or LO fan E air con will only blow out air without cooling While the air conditioner running its mode selection shouldn t be shifted frequently between fan and cool LO fan and LO cool d Operation Guide Thermostat switen This switch will control preset indoor temp COOL E to make air con start or stop automatically 5 so as to reduce power consumption and possess an economical and worthwhile cool circumstance 9 Remarks The compressor will stop running 1 Test when the set temperature is reached run but the fan remains running to realize the even indoor temperature Operate the switch as follows Temp decreases as the switch is turned from 1 to 9 Temp increases as the switch is turned from 9 to 1 Test run marked with means air con is in trial operation When set to this position air con will run continuously regardless of temp setting Don t use test run for normal operation Vertical Airflow Direction Vane Airflow Vertical airflow direction direction adjustment Up and Down adjustment oe The Vertical Airflow Direction Vane is controlled by positioning the vane to discharge the air upwards downwards or straight out Maintenance NOTE Always unplug the air conditioner before servicing or
6. WINDOW TYPE ROOM AIR CONDITIONER Haier IHERMOCOOL OPERATION MANUAL HW 09CV03 HW 12CV03 Please read this operation manual before using the air conditioner No 0010503559 Contents Pats IM cm 1 Operation GUJE sut tedoen uut ioc cmt c dedo d 2 4 ET 5 7 ENOS RR T 8 Trouble Shoting sssr scis COE POL m 9 Installation Guide 10 12 o o Pas Y HW 09CV03 HW 12CV03 Front panel Air inlet indoor side Air outlet indoor side Air inlet outdoor side Operation panel Operation Guide Operation panel Auto swing switch ZN Auto swing Temp setting Mode selection After unit stops don t restart it until 3 min have elapsed Thermostat switch Mode selection switch Operation Guide e Auto swing switch When the switch is set to ON vertical louver will swing from side to side delivering gentle air thus making you OFF ON feel very CANS When it is set to OFF vertical louver will stop at position Mode selection switch Mode switch controls the fan motor speed Cooling speed or fan speed 1 When set to HI fan fan motor runs at high speed to blow out strong air 2 When set to LO fan fan motor runs at low speed to blow out gentle air 3 When set to HI cool air con will start speedy cooling blowing out strong air 4 When set to LO cool air con will start cooling at low
7. ed In the both methods above an extended hose available on the market can be connected to the drain connecting pipe if necessary Cautions Power cord Be sure to use the exclusive power cord Change installation place If air con need to be changed to another place please contact the dealer who sold you the unit Maintenance eAvoid opening door and window e Don t be exposed to cold air for unless necessary a long time Use curtain or blind Keep heat source away from Direct sunlight may reduce cooling air conditioner effect always use window curtain Keep away from me AM JA e Set temp a little bit higher After unit stops don t restart it before going to bed until 3 min have elapsed No entrance OK enjoy a 3 min nap Cautions e Don t hang clothes in the vicinity of air inlet This will decrease cooling effect and cause abnormal operation Temperature should be set properly when there are infant child the aged or disabled in room Baby has gone sleep had better adjust suitable temp Before operating mode selection Switch check if the air inlet or outlet have been blocked For longer and trouble free operation of the unit pay special attention to the following 9 Install air con at a place strong enough to support the unit Leave enough space around air inlet and outlet for better circulation Avoid places where flammable gas leaks
8. the air conditioner on the iron support If there amp L Drain connecting ETUR d ipe is a drain hose lead it to a required place eed circle 0 pip see Fig 5 Drain hose Fig 4 11 Installation instruction 8 Chink the wall and window with soft sponges or rubber bits in order to refrain from outside noises coming in or cooling air going out Wall 9 Air conditioner being fixed insert the power plug in the socket open the operation panel cover turn the temperaure setting to Test run turn successively the mode selection to Hi fan and Hi cool Lo cool and Lo fan inspect the air conditioner s start and running performance Drain hose 10 If Test run is normal turn mode selection to OFF turn the temperature setting to 9 Now the air conditioner is ready for use The machine is adaptive in following situation 1 Applicable ambient temperature range iid id Maximum D B W B 32 C 23 C alee Minimum D B W B 18 C 14 C Cooling Outdoor side NOUIS D B W B 43 C 26 C Minimum D B 18 C 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person Power cable 3x1 5mm 3 After installation the power plug should be easily reached 4 The wiring method should be in line with the local wiring standard 12 Wiring Diagram 7363749 WIRING DIAGRAM BOATSWITCH SYNCHROMOTOR OPTIONAL SWITCH LO FAN LO
9. tion where there s no dangerous gas or oil smoke nearby 8 An extension cord is not recommended Installation diagram It should be installed like this the back side outdoor side is lower so that the drained water can flow out smoothly Width of the wall should be less than 295mm M 7 Requirements on electricity Be sure to use specific power circuit The enclosed accessories of the conditioner are 1 1 10 Installation instruction The installation of air conditioner only for reference 1 Cut a wall hole or a window hole see Fig 1 Iron support HW 09CV03 HW 12CV03 8 2 Fix the iron support in a firm place with Thickness of the wall expansible screws Fig 1 Condenser 3 Take the air conditioner and its attach ments out from the packing carton 4 Let the rear of the air conditioner raise Ip slightly the drain hole on the bottom can stopper Clog it with a black rubber stopper attached 24 to the air conditioner see Fig 2 Fig 2 5 Insert the drain connecting pipe with a seal circle attached to the air conditioner into the vertical drain hole on the bottom see Fig 3 6 The condensate needing to be led to the designated place buy a soft plastic pipe with internal diameter of 16mm to connect the drain connecting pipe and tied it tightly 7 All attachments being fixed put

Download Pdf Manuals

image

Related Search

Related Contents

RK-433-RC USER`S MANUAL  Kanon in BALLADE - AKAI professional EWI  KISS BR58 - Kiss Modellbahnen  Brother Innov-is 990D Sell Sheet  Samsung C23A550U Uživatelská přiručka  TSK300  設定方法  「家具 Version1.3」 認定基準書  - Bambozzi    

Copyright © All rights reserved.