1. Auto swing OFF ius THREE MINUTES BEFORE RES TARTING E Thermostat switch Mode selection switch Operation Guide Auto swing switch When the switch is set to and vertical louvers will swing from side to side 7 delivering gentle air thus making you feel very comfortable When it is set to O the indicator VEN Auto swing goes out and the vertical louvers stop at any position Mode selection switch Mode selection switch controls the fan motor speed and cooling speed 1 When set to HIGH FAN fan motor runs at high speed to blow out strong air 2 When set to LOW FAN fan motor runs at low speed to blow out gentle air 3 When set to LOW COOL air conditioner will start cooling at low speed blowing out gentle air When set HIGH COOL air conditioner will start speedy cooling blowing out strong air lt 4 lt 5 When set to OFF air conditioner stops running When the mode selection switch is turned to HIGH FAN or LOW FAN the air conditioner will only blow out air without cooling If the mode selection switch is turned from cooling mode to fan mode do not turn it back until at least 3 minutes have elapsed Operation Guide Thermostat switch This switch controls the preset indoor temperature to makethe air conditioner start or stop aut
2. modes Fig 1 Fig 2 Outlet pipe fitting Rubber lid Back hole A WS Back hole hs Rubber lid outlet pipe SN Bottom plate hole Bottom plate hole Cautions Power cord Be sure to use the exclusive power cord Change installation place If air con need to be changed to another place please contact the dealer who sold you the unit Maintenance Avoid opening doors and windows unless necessary g a f i Use curtain or blind Direct sunlight may reduce cooling effect always use window curtain P Settemp a little bit higher before going to bed Proper temperature e Don t be exposed to cold air for a long time 9 Keep heat source away from air conditioner e After unit stops don t restart it until 3 min have elapsed OK Enjoy a 3 min nap Troubleshooting Readjust power supply Replace fuse Doesn t work Is plug firmly inserted Is there power failure Readjust the thermostat Use curtain or blind Does fuse get burned Is thermostat switch wrongly adjusted No cool air or poor cooling Shut doors and windows Is there any direct sunlight in the room Remove the obstacles Are doo
3. the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered As illustrated in Fig 1 2 For the convenience of operation it is recommended that air conditioner be installed at least at the height of 760 1300 mm above the floor and no obstacles before it for a free airflow 3 The shutters at both sides and the top of air conditioner should be protruded outdoors free from being blocked by wall window etc 4 The back of air conditioner should be kept over 500mm from the obstacles for example wall etc As illustrated in Fig 2 5 To have an efficient drainage the back part of the air conditioner should be inclined downward by 5 10mm As illustrated in Fig 3 5 10nm support fig 1 fig 2 The enclosed accessories of the conditioner are Name Manual Outlet pipe fitting Sealed gasket Drain pan Screw Figure E B O Quantity 1 1 1 1 2 11 Installation Guide Installation of air conditioner only for reference Iron frame 1 Make the wall hole or window hole see Fig 1 2 Fix the prefabricated iron frame to stable position by expansible screws 450 TS 3 3 Take out the conditioner and accessories Width of the wall from the package Fig 1 4 Cooling only type air conditioner before dispatched Condenser from the factory the drip hole at the bottom plate has been blocked by rubber lid in the accessories I
4. WINDOW TYPE ROOM AIR CONDITIONER OPERATION MANUAL HW 07LM13 HW 07LM03 HW 09LM13 HW 09LM03 HW 12LM13 HW 12LM03 Please read this operation manual before using the air conditioner Please keep it attentively No 0010515220 Contents anie e 2 Pant Name cies eve eee 3 Operation GUI 4 5 Maintenant 6 8 Trouble Shooting 9 Installation 1 5 10 fats Ell fe oa rer a 11 12 The machine is adaptive in following situation 1 Applicable ambient temperature range D B W B 32 C 23 C inimum _D B W B 18 C 14 C Maximum D B W B 43 C 26 C 2 If the supply cord is damaged it must be replaced by the manufacturer or its serviceagent or a similar qualified person 3 After installation the power plug should be easily reached 4 The wiring method should be in line with the local wiring standard Parts Machine body Front panel Air inlet indoor side Machine body Air outlet indoor side 1 Air inlet outdoor side Display panel SOC Power plug Air filter inside Auto swing switch Operation panel
5. f the surrounding humidity is high should assemble drainage bend in the drainage hole at the back of bottom plate and connect the drainage tube as P illustrated in Fig 3 If the user doesn t need to Rubber lid CM retain the condensate in the bottom plate can Drain pn NON remove the rubber lid on the bottom and as illustrated in Fig 2 assemble the attached drain Fig 2 pan on the bottom of the air conditioner and connect drainage tube at the water outlet hole on the drain pan Condenser 5 If you need to lead the condensed water to indicated position please purchase a piece of plastic pipe set it on the outlet pipe fitting and tie it tightly Water outlet flexible pipe provide by user 6 After installation of all the accessories put the whole machine on the iron frame If there s water outlet flexible pipe lead the pipe to needed position see Fig 4 Fig 3 Wall 7 Fill any distance between the wall hole and the machine body with flexible sponge rubber strip to prevent the entering of outer noise and the leaking of the coolness Water outlet flexible pipe provide by user Fig 4 8 After installation of the conditioner insert the power plug into the outlet and perform test run 12
6. omatically so as to reduce power consumption and operate the system both comfortably and economically Remark The compressor stops running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature Airflow Direction Vane Vertical airflow direction e The Vertical Airflow Direction Vane is manually controlled by positioning the vane todischarge the air upward downward or straight out The horizontal air direction is adjusted by setting the AUTO SWING switch to the ON position Note tis advisable not to keep vertical flap at downward position for a long time in COOL or FAN mode otherwise condensate water might occur Don t move the horizontal flap with hand in order to avoid the vertical flap abnormal using the remote controller to adjust the move of vertical flap N C CAUTION n cooling mode after you turn thermostat switch counter clockwise do not turn it back until at least 3 minutes have elapsed Otherwise the fuse may blow due to overload Do not exceed the selection range Maintenance Air filter cleaning before cleaning turn off the power When dirt accumulates on air filter air circulation will be blocked which causes poor cooling It is advisable to clean air filter every two weeks for longer operation Take out the air filter 1 Press the concave parts on both sides at the lower pa
7. rs or windows left open Are there any obstacles blocking air inlet and outlet Is air filter clogged Remove the heat source Is there too much heat 3 E source in the room If problems can not be solved please pull out power plug and contact your dealer M Installation Instructions e Don t hang clothes in the vicinity Temperature should be set of air inlet This will decrease properly when there are infant cooling effect and cause abnormal child the aged or disabled operation in the room Baby has gone sleep better to adjust e Before operating mode selection switch check that if the air inlet or outlet have been blocked For longer and trouble free operation of the unit pay special attention to the following e Install air con at a place strong enough to support the unit e Leave enough space around air inlet and outlet for better circulation Avoid places where flammable gas leaks Problems may occur if unit is installed in the following places Place where oil exists in the air including engine oil or seaside with salt breeze blows and hot spring area with sulphurous gas in the air 10 Installation Guide Selection of the installation position 1 The air conditioner is better installed in shadow or in a place with short period of sunshine In case the air conditioner is installed at the point exposed directly to the sunshine it should be protected from
8. rt of air inlet grille to open the air inlet grille 2 Hold the hump of filter mesh with fingers as illustrated and take it out Air filter cleaning 1 Gently flap the dirt off the air filter 2 Carefully wash air filter in warm water below 40 C To obtain better cleaning effect soap water or neutral detergent may be used 3 Flush air filter carefully with clean water after removing dirt Let it dry completely Maintenance Disposal of the condensed water Generally there are two methods available on disposal of the condensed water 1 Block the bottom plate hole of the conditioner with rubber lid install outlet pipe fitting on the back hole and let the condensing water flow from the back hole of the conditioner See Fig 1 In this method the accumulated condensed water in the bottom plate is hit by the fan onto the heat exchanger and evaporated and blown out from the machine It can cool the heat exchanger radiator more quickly and improve the energy efficiency of the conditioner But the hitting noise by the fan at the outdoor side is relatively large 2 Block the back hole of the conditioner with rubber lid and install outlet pipe fitting to the bottom hole which can make the condensed water flow out from the bottom plate See Fig 2 If necessary the above two methods can both have extra pipe added on the outlet pipe fitting available on the market Refer to P12 for choosing these two