Home

Haier 10515222 User's Manual

image

Contents

1. 10 ON OFF button Used for unit start and stop 11 TIMER ON display 12 FAN SPEED display at_ sal LOW MED 13 LOCK display 14 SWING UP DOWN display 15 SLEEP display 16 HEALTH display 17 Operation mode display iall AUTO Operation mode AUTO COOL DRY FAN Remote controller 7 x amp Display board 18 Singal sending display 19 POWER SOFT display 20 Left right air flow display 21 TEMP display Remote controller to display the TEMP setting 22 TIMER OFF display 23 CLOCK display 24 TEMP button Used to select your desired temperature 25 FAN button Used to select fan speed LOW MED HI AUTO 26 HEALTH AIRFLOW button Used to set the health airflow mode 27 SWING UP DOWN button Used to select up or down air sending direction 28 SWING LEFT RIGHT button Used to select left right air flow 29 FRESH button optional Use to set fresh air function 30 SET button Used to confirm timer and clock settings 31 POWER SOFT button Used to set power soft function 32 LOCK Used to lock buttons and LCD display If pressed the other buttons will be disabled and the lock condition display appears Press it once again lock will be canceled and lock condition display disappears 33 Remote signal receiver 34 Emergency operation button touch key Used to set emergency operation and test operation NOTE 1 Cooling only unit do not have functions and
2. displays related with heating 2 The CODE button on this remote controller is not available Parts and Functions E Clock Set When unit is started for the first time and after replacing batteries in remote controller clock should be adjusted as follows 1 Press CLOCK button AM or PM flashes 2 Press or to set correct time Each press will increase or decrease 1 min If the button is kept depressed time will change quickly MODE HEALTH AIRFLOW SLEEP FRESH CLOCK 3 After time setting is confirmed press SET AM or PM stop flashing while clock starts working TE OO E Remote controller s operation When in use put the signal transmission head directly to the receiver hole on the indoor unit The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter Loading of the battery Load the batteries as illustrated right 2 R 03 7 batteries Remove the battery cover Slightly press 7 area and push down the cover as illustrated Load the battery ay AF Be sure that the loading is in line with the lt request as il
3. health airflow function the position of inlet and outlet grills is fixed 2 In cooling it is better to select the mode 3 In cooling and dry using the air conditioner for a long time under the high air humidity a phenomenon falling drips of water occurs at the outlet grille 4 Select the appropriate fan direction according to the actual conditions 18 Operation Emergency and Test Operation wall mounted type Emergency operation e Use this operation only when the remote controller is defective or lost e When the emergency operation switch is pressed the Pi sound is heard once which means the start of this operation e In this operation the system automatically selects the operation modes cooling or fan according to the room temperature Operation Designated Air flow Temperatur mode temperature ABOVE 21 C COOLING 24 C AUTOMATIC BELOW 21 C 24 C AUTOMATIC elt is not possible to operate in dry mode Test operation Test operation switch is the same as emergency switch e Use this switch in the test operation when the room temperature is below 16 C do not use it in the normal operation e Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed Hi e
4. same time in order take out the AIP layer board in turns ka L Note the green aspect of the bacteria killing e eee E OL i 7 i A medium air purifying filter will face outside the I L white aspect will face to the machine The m e Tal yellow aspect of the VC layer will face outside the white aspect will face to the machine 4 The installation of AIP layer VC layer Bacteria killing medium sets must be installed f 7 7 s i mi i I 5 Mm y ET E 5 Close the Inlet Grille Put down the inlet grill s top plate and close the inlet grill gt Common sense in order to keep the AIP layer having a highly work effect it should be cleaned regularly or aperiodically just according to the working environment 1 Turn off the A C electricity supply and make sure that AIP layer is not working Then clean the AIP layer after turning off it five minutes later 2 Please brush off the dust on AIP board then steep it into cleaning agent water and wash it 3 After cleaning AIP board pleas put it on a dry place until it is totally dr
5. 4 F may cause damage the coating of the unit discoloring or deformation Air Filter cleaning 1 Open the inlet grille by pulling it upward 2 Remove the filter Push up the filter s center tab slightly until it is released from the stopper and remove the filter downward 3 Clean the filter Use a vacuum cleaner to remove dust or wash the filter with water After washing dry the filter completely in the shade 4 Attach the filter Attach the filter correctly so that the FRONT indication is facing to the front Make sure that the filter is completely fixed behind the stopper lf the right and left filters are not attached correctly that may cause defects 5 Close the inlet grille 21 Maintenance The installation and cleanout AIP layer VC layer Bacteria killing medium sets 4 Open the Inlet Grille l y ye inlet grill s top plate The inlet grill is supported by its top n w a plate at the right side 2 Detach the standard air filter Push up the filter s center tab slightly until it is released from the stopper and remove the filter downward AlP air ionization purify 3 Take the VC layer Bacteria killing bottom frame medium sets A A r Take out Take the VC layer or the Bacteria killing at mi medium sets from the filter Push the bottom frame AIP board of AIP layer and push up the handle at the
6. 6 Time confirming for TIMER OFF After time setting press SET button to confirm aa on the remote controller stops blinking Time displayed Unit stops at x hour x min To cancel TIMER mode Just press TIMER button several times until TIMER mode disappears According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved 16 O pe ration POWER SOFT Operation Remote controller POWER Operation When you need rapid cooling you can use this function Selecting of POWER operation Press POWER SOFT button Every time the button is pressed display changes as follows 7 gt N BLANK POWER SOFT Stop the display at In POWER operation status In COOL mode compressor runs in high frequency for 15 min then returns to original status setting To cancel POWER operation Press POWER SOFT button twice ROWER SOFT disappears SOFT Operation You can use this function when silence is needed for rest or reading Selecting of SOFT operation Press POWER SOFT button Every time the button is pressed display changes as follows 7 N BLANK POWER SOFT Stop the display at In SOFT operation mode fan eer automatically takes ultra low To cancel SOFT operation Press POWER SOFT button twice ROWER SOFT disappears Hints During POWER operation in rapid COOL mode the room will show inhomogeneou
7. After 30 minutes test operation ends automatically Removal of the restriction of emergency or test operation e Press the emergency operation switch once more or manipulate through the remote controller the Pi sound the emergency or test operation is terminated e When the remote controller is manipulated it gets the system back to the normal operation mode 19 Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used for a long time turn off the power supply main switch 20 Maintenance For Smart Use of The Air Conditioner A WARNING Before maintenance be sure to turn off the system and the circuit breaker Indoor Body Remote Controller Wipe the air conditioner by using a soft and Do not use water wipe the controller with a dry cloth For serious stains use a neutral dry cloth Do not use glass cleaner or chemical detergent diluted with water Wring the water cloth out of the cloth before wiping then wipe off the detergent completely Do not use the following for cleaning S tanh a Gasoline benzine thinner or cleanser may Hot water over 40 C 10
8. J Operation Before going to bed you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep J Use of SLEEP function After the unit starts set the operation status then press SLEEP button before which the clock must be adjusted and time being set Operation Mode 1 In COOL DRY mode 1 hours after SLEEP mode starts temp will become 1 C higher than temp setting After another 1 hours temp rises by 1 C further The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep Remote Controller 14 a SLEEP operation starts SLEEP operation stops Approx 6hrs Temp setting Unit stop C In COOL DRY mode 2 In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode 3 In FAN mode It has no SLEEP function 4 When TIMER function is set the sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on 5 Note to the power failure resume press the sleep button ten times in five seconds and enter this function after hearing four sounds And press the sleep button ten times within five seconds and leave this function after hearing two sounds Power Failure Resume Function If the unit is started f
9. SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU 12CR03 Y HSU 18CR03 Y e Please read this operation manual before using the air conditioner 0010515222 Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use please make sure it s inop erative and safe Unplug the air conditioner in order to avoid the risk of child entrapment It must be noticed that air conditioner system contains refrigerants which require speciali zed waste disposal The valuable materials contained in an air conditioner can be recycled Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon All these valuable materials may be taken to a wast
10. TO COOL DRY FAN Then Select DRY operation 3 Select temp setting sone Aes Press TEMP button oe A Every time the button is pressed temp setting increase 1 C if kept depressed it will increase V Every time the button is pressed temp setting decrease 1 C if kept depressed it will decrease merge ay S rapidly Select a desired temperature 4 Fan speed selection Press FAN button For each press fan speed changes as follows Remote controller PROP EOP ttl LOW MED HI AUTO Air conditioner is running under displayed fan speed In DRY mode when room temperature becomes lower than temp setting 2 C unit will run intermittently at LOW speed regardless of FAN setting COOL operation starts when room temp is higher than temp setting Ultra low air flow 5 Unit stop Elna e Aa Press ON OFF button the unit stops unit will run in mild DRY mode Temp setting 2 C Temp setting 11 Ope ration Fan Operation Ge aT G Display board dH oO 1 Unit start Remote controller Press ON OFF on the remote controller unit starts 2 Select operation mode Press MODE button For each press operation mode changes as follows Remote controller AUTO COOL DRY FAN Then Select FAN operation 3 Fan speed selection Press FAN button For each press fan speed changes as follows Remote controller a LOW MED HI 4 Unit stop Press ON OFF butt
11. e any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner s tubes with sharp or pointed items crushing or twisting any tubes or scraping the coatings off the surfaces If the refrigerant spurts out and gets into eyes it may result in serious eye injuries Cautions e Do not obstruct or cover the ventilation grille of the air conditoner Do not put fingers or any other things into the inlet outlet and swing louver e Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit Specifications e The refrigerating circuit is leak proof The machine is adaptive in following situation 1 Applicable ambient temperature range 35 C 24 C 18 C 14 C 46 C 27 C 18 C Maximum D B W B Minimum D B W B Maximum D B W B Minimum D B Indoor Cooling Outdoor 2 If the power supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 3 If the fuse of indoor unit on PC board is broken please change it with the type of T 3 15A 250V 4 The wiring method should be in line with the local wiring standard 5 After installation the power plug should be easily reached 6 The waste battery should be disposed properly 7 The appliance is not intended for use by young children or infirm persons without supervision 8 Young chi
12. e collecting center and used again after adequate recycling Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house Safety Instructions and Warnings Before starting the air conditioner read the information given in the User s Guide caref ully The User s Guide contains very impor tant observations relating to the assembly operation and maintenance of the air conditioner The manufacturer does not accept respon sibility for any damages that may arise due to non observation of the following instruction e Damaged air conditioners are not to be put into operation In case of doubt consult your supplier e Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User s Guide e Installation shall be done by professional people don t install unit by yourself e For the purpose of the safety the air con ditioner must be properly grounded in acco rdance with specifications e Always remember to unplug the air conditioner before openning inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the outlet e All electrical repairs must be carried out by qualified electricians Inadequate repairs may result in a major source of danger for the user of the air conditioner e Do not damag
13. ldren should be supervised to ensure that they do not play with the applience 9 Please employ the proper power plug which fit into the power supply cord 10 The power plug and connecting cable must have acquired the local attestation 11 In order to protect the units please turn off the A C first and at least 30 seconds later cutting off the power Cautions Safety Instruction e Please read the following Safety Instructions carefully prior to use e The instructions are classified into two levels WARNING and CAUTION according to the seriousness of possible risks and damages as follows Compliance to the instructions are strictly required for safety use Installation A WARNING Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage Installation in a inadequate place may cause accidents Do not install in the following place A CAUTION Connect the earth Do not install in the place where there is any possibility of inflammable gas leakage around the unit S PROHIBITION Do not get the unit exposed to vapor or oil steam S PROHIBITION Check proper installation of the drainage securely J IL ENFORCEMENT Cautions A WARNING When abnormality such as burnt small found immediately stop the operation button and contact sales
14. lustrated on the bottom of the case Put on the cover again Confirmation indicator After pressing power ON OFF if no display reload the batteries Note Full display or unclear display during operation indicates the batteries have been used up Please change batteries Used two new same typed batteries when loading if the remote controller can t run normally during operation please remove the batteries and reload several minutes later Hint Remove the batteries in case unit won t be in usage for a long period If there are any display after taking out just need to press reset key Operation HEALTH operation Display board Remote controller 1 Unit start Press ON OFF on the remote controller unit starts 2 Health anion function Press Purify button 4 is displayed on the remote controller and is displayed on the display board Air conditioner starts air ionization purify and health anion function operation For twice press 4 and disappear the operation stops When indoor fan motor is running it has air ionization purify and healthy process function BRIEF INTRODUCTION TO AIR IONIZATION PURIFY AND HEALTH ANION FUCTION 1 The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the ro
15. ntil TIMER mode disappears After replacing batteries or a power failure happens time setting should be reset Remote controller possesses memory function when use TIMER mode next time just press SET button after mode selecting if time setting is the same as previous one 15 Ope ration Timer On Off Operation C Display board H Set clock correctly before starting Remote Controller TIMER operation 1 After unit starts select your desired operation mode Operation mode will be displayed on LCD 2 Timer mode selection Press TIMER button to change TIMER mode Every time the button is pressed display changes as follows Remote controller 0N M Gag BLANK itho ien 200 TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON OFF will flash 3 Time setting Press HOUR AV V button A Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly V Every time the button is pressed time setting decreases 1 min if kept depressed it will decrease rapidly It can be adjusted within 24 hours 4 Timer confirming for TIMER ON After setting correct time press TIMER button to confirm EM on the remote controller stops flashing ta starts flashing Time displayed Unit starts or stops at x hour x min 5 Time setting for TIMER OFF Just press HOUR button follow the same procedure in Time setting for TIMER ON
16. om 2 The purification function of AIP DC high voltage bring high voltage electrostatic field which ionize air into positive and negative ion a great deal of positive and negative ion adhere to dust passing by so the dust become particle with electric charge so the dust passing by adheres to the AIP board under the force from the electric field which purifies the unit 3 When power off press the purify button the Remote controller shows FAN low AIP and negative ion and the TIMER function is available Operation Display board Remote controller Auto Operation dh 1 Unit start Press ON OFF on the remote controller unit starts 2 Select operation mode Press MODE button For each press operation mode changes as follows Remote controller Then gt AUTO COOL DRY FAN Select Auto operation 3 Select temp setting Press TEMP button A Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly V Every time the button is pressed temp setting decrease 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection Press FAN button For each press fan speed changes as follows Remote controller P PEOP EOT FOTI Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room tempe
17. on e Incomplete earthing may cause an electric shock EARTHING A Caution e After brush away dust at the plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND 24 Trouble shooting Before asking for service check the following first Phenomenon Cause or check points The system does not restart e When unit is stopped it won t restart immediately immediately until 3 minutes have elapsed i P to protect the system e When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner e During unit operation or at stop a swishing or gurgling noise may be heard At first 2 3 minutes after unit start this noise is more noticeable This noise is generated by refrigerant flowing in the system Normal e During unit operation a cracking noise may Performance be heard This noise is generated by the inspection casing expanding or shrinking because of temperature changes e Should there be a big noise from air flow in unit operation air filter may be too dirty e This is because the system circulates smells Smells are generated from the interior air such as the smell of furniture cigarettes Mist or steam are blown out e During COOL or DRY operati
18. on indoor unit may blow out mist This is due to the sudden cooling of indoor air e Is power plug inserted Does not work at all e Is there a power failure e Is fuse blown out Is the air filter dirty Normally it should be cleaned every 15 days Are there any obstacles before inlet and outlet e ls temperature set correctly e Are there some doors or windows left open e Is there any direct sunlight through the window during the cooling operation Use curtain e Are there too much heat sources or too many people in the room during cooling operation Poor cooling 25
19. on the unit stops About FAN operation In FAN operation mode the unit will not operate in COOL mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode SLEEP operation is not available 12 Operation Air Flow Direction Adjustment 1 Status display of air sending Horizontal flap Vertical blade Pos 1 R Pos 1 a Pos 2 Pos 2 7 Pos 3 Pos 3 FS Pos 4 K Pos 4 z Pos 5 iL Pos 5 T Pos 6 Auto swing ME Pos 7 S Pos 8 AISNE aa 2 Up and down air flow direction For each press of lt gt button air flow direction on remote controller displays as follows according to different operation modes oe ie Pos 1 Pos 2 Pos 3 Pos 4 Pos 6 AUTO hated ok controller gt Pos Pos 2 Pos 3 gt Pos 4 gt Pos 5 Pos 6 The horizontal flap will swing according to the above positions 3 Left and right air flow direction For each press of gt button remote controller displays as follows remote controller i Pos 1 gt Pos 2 gt Pos 3 gt Pos 4 Pos 5 gt Pos 6 gt Pos 7 Pos 8 The vertical blade will swing according to the above positions Note When restart after remote turning off the remote controller will automatically memorize the previous set swing position 13 Operation Sleep Operation A dh Po Ie ay Display board EEN
20. or the first time the compressor will not start running unless 3 minutes have elapsed When the power resumes after power failure the unit will run automatically and 3 minutes later the compressor starts running Operation Timer On Off Operation Cieenlay board gt Remote Controller el Ju alll INN AMI uu uu DAI ae ee P FRESH SWING Hints cu Set clock correctly before starting TIMER operation 1 After unit starts select your desired operation mode Operation mode will be displayed on LCD 2 Timer mode selection Press TIMER button to change TIMER mode Every time the button is pressed display changes as follows Remote controller gt Poy gt N BLANK edo ed 200 TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF EN or i will flash 3 Time setting Press HOUR A V button A Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly V Every time the button is pressed time setting decreases 1 min if kept depressed it will decrease rapidly It can be adjusted within 24 hours 4 Confirming your setting After setting correct time press SET button to confirm ME or on the remote controller stops flashing Time displayed Unit starts or stops at x hour x min TIMER ON or TIMER OFF 5 Cancel TIMER mode Just press TIMER button several times u
21. rature 5 Unit stop Press ON OFF button the unit stops About Auto Operation Under the mode of auto operation air conditioner will automatically select Cool Dry or Fan operation according to room temperature Operation Cool Operation n 1 Unit start p _ Press ON OFF on the remote controller unit starts Re ote controller _ 2 Select operation mode _ Press MODE button For each press operation mode changes as follows Remote controller AUTO COOL DRY FAN Then Select COOL operation 3 Select temp setting Press TEMP button A Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly V Every time the button is pressed temp setting decrease 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection Press FAN button For each press fan speed changes as follows Remote controller PEOP EOT FOTI LOW MED HI AUTO Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature 5 Unit stop Press ON OFF button the unit stops 10 Ope ration Dry Operation a Remote co D 1 Unit start a RE Press ON OFF on the remote controller unit starts 2 Select operation mode Press MODE button For each press operation mode changes as follows Remote controller AU
22. s a n pS N Indoor unit A air ionization purify layer inside Air filter inside Vitamin C layer Bacteria killing medium sets inside Outlet Inlet Inlet grille I display board inside Horizontal flap adjust up and down air flow Don t adjust it manually Anion generator inside Vertical blade inside adjust left and right air flow Power plug Pe S Outdoor unit gt w 2 lt Z gt 7 4 OUTLET G CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE Parts and Functions eect PHO ObR x Fa PROBE iW OOGOOOOH OOOO 1 CODE Used to select CODE A or B with a press A or B will be displayed on LCD Please select A without special explanation 2 RESET When the remote controller appears abnormal use a sharp pointed article to press this button to reset the remote controller normal 3 LIGHT button Control the lightening and extinguishing of the indoor LED display board 4 TIMER button Used to select TIMER ON TIMER OFF TIMER ON OFF 5 CLOCK button Used to set correct time 6 SLEEP button Used to select sleep mode 7 MODE button C V b i AUTO COOL DRY FAN 8 HOUR button Used to set clock and timer setting 9 Purify button Used to set air ionization purify and healthy function O fi OO O 66 6608
23. s temperature distribution Long period SOFT operation will cause effect of not too cool 17 Operation Health airflow Operation 1 Press ON OFF to starting Kanoe tanio The liquid crystal will display the working state of last time Except timer sleeping power soft and health airflow Setting the comfort work conditions 2 The setting of health airflow function 1 Press the button of health airflow F appears on the display The nether inlet and outlet grills of the air condit ioner are closed and the airflow is blown horizontally from the above inlet and outlet grills Avoid the strong airflow blows direct to the body 2 Press the button of health airflow again appears on the display The above inlet and outlet grills of the air cond itioner are closed and the airflow is blown vertically from the nether inlet and outlet grills Avoid the strong airflow blows direct to the body 3 The cancel of the health airflow function Press the button of health airflow again both the inlet and outlet grills of the air conditioner are opened and the unit goes on working under the condition before the setting of health airflow function After stopping the outlet grille will close automatically Notice Cannot pull direct the outlet grille by hand Otherwise the grille will run incorrectly If the grille is not run correctly stop for a minute and then start adjusting by remote controller Note 1 After setting the
24. shop Connect power supply cord to the outlet completely STRICT ENFORCEMENT Do not use power supply cord in a bundle PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on PROHIBITION circuit breaker STRICT ENFORCEMENT Use the proper voltage Q STRICT ENFORCEMENT Take care not to damage the power supply cord S PROHIBITION TINS Do not channel the air flow directly at people especially at infants or Use an exclusive power source with a Do not use power supply cord extended or connected in halfway PROHIBITION Do not insert objects into the air inlet or outlet bb PROHIBITION Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation e ee DEP PROHIBITION Do not install the unit near a fireplace or other heating apparatus A a PROHIBITION Do not place animals or plants in the direct path of the air flow PROHIBITION STRICT Check good condition of the installation stand S PROHIBITION Do not place any objects on or climb on the unit PROHIBITION PROHIBITION Do not pour water onto the unit for cleaning 4b PROHIBITION Do not place flower vase or water containers on the top of the unit PROHIBITION Parts and Function
25. y 4 Ensure AIP board is dry enough then install it in the its position along the slide way Make sure it is as before and could work well The AIP layer will be replaced in fixed time In normal family it will be replaced every 6 months n the use please note to clean the filter frequently take off the back suction cleaner or lightly pat it to avoid the operating effect is lowered due to the dust covering the filter AIP layer and bacteria killing medium filter is strictly prohibited from being cleaned by water The the bacteria killing medium filter not in use should be stored in shade cool and dry place one don t expose it to the sunlight for a long time otherwise the degerming performance will drop J 22 Maintenance To Keep Your Air conditioner in Good Condition after Season C N 1 Operate in cooling mode for 2 3 hours To prevent breeding mold or bad smell be sure to operate at the designated temperature or 30 C cooling mode and High speed fan mode for 2 3 hours 2 Put off the power supply gt cord 3 Cleaning the body 4 Take out the batteries from the wireless remote controller 23 Maintenance Before Setting in High season 1 Cleaning the standard air filter Operation without filter may cause troubles Be sure to attach both right and left filters prior to the operation Each of them are of different shapes 2 Connecting the earthing cable A Cauti