Home

GVision 3.54 User's Manual

image

Contents

1. GVI Release Notes Version 3 54 January 12 2007 Please check http www tascam com for the latest updates Manitial Aden ditii tssccccccccrccctcdcaccctada eit beccach evecadaschecdeaedealedanehedeadeadenedaidbeddededbatedeeabedeageene 1 Using GVI and the VSL Performance Tool cee eeeesseesseceseeeeeeeeseeenaeeneenseeeeneees 1 New Featiare 11 354 2 ieccccccs cece cdcavdeesctexsvecdeavecesdectuvesccebieacedesivetaeeiteusdectuvetecestocetediveteeebeved 1 GSI Expansi n PLS LOC x 5cde sca tiednasstecaistsbencteqsesseveassnedncg dueapiesaueiusqneuseeenmneiens tees 1 New F at re 1103 53 i ccccisecsecencesscacncdsnestrcestecencdsnssyacesacewdcdvaestacented wacedeuetacerssewucdvenstecesteesen 1 Windows XP Ofret n ENARRARE RRT ARER ARONNE 1 New Feature m 3S Zeena E E E E R 2 Bank Patch Manag eronsa adeno a ateeeauennasuiaeees 2 New Beattires In 3S luieren en A R ERA A RS 2 NEX Ge E E E A O E E E 3 Maintenance Items in 3 54 nesseeeeeeeseeeeeresereerreerresrresrsesrseseeesrserneeerneereeeeeeseeeereeseseereee 4 Maintenance Items in 3 53 eesseeeseeesreeerresereerersrresrresrresrseseresrseeneeereeereeeereseeeeeeeeeeeseees 4 Maintenance ems 11325 2 inienn anaa a a EA a Aa Aa EA REN A 4 Maintenance Itemis In 3 5 loisena inerea aar ER O a R N aaa iS 5 Known Issues In 3 54 ccccccccccccccccccccccceeccceseeeseeeeeeeeeeeeeeeeeeeseeeseeeseeeseeeseeeeseeseenseeseeeeseeegs 5 Manual Addendum Using GVI and the VSL Performance Tool 1 Download the M
2. aple MIDI Router Free from http www marblesound com 2 Open GVI as a plug in in your host DAW 3 Set the Performance Tool input to physical in and output to Maple MIDI router 4 Set the DAW track s input to the Maple virtual MIDI cable and its output to GVI New Feature in 3 54 GSI Expansion Preference A check box has been added to the GVI System Configuration window in the General tab that when checked forces stacked instruments to open in an expanded view state Without this box checked stacked instruments will open in a collapsed view state New Feature in 3 53 Windows XP 64 GVI has been tested on Windows XP 64 systems and found to be compatible New Feature in 3 52 Bank Patch Manager The following functionality has been added to the Loaded Instrument Viewer Right click an instrument to display the Bank Patch Manager interface o Pressing Resolve All Conflicts will automatically assign new Bank Patch values to loaded instruments to eliminate duplicates o The bank and or patch number of the selected instrument can be manually changed New Features In 3 51 GVI now supports multiple instances on multi processor dual core computers for Steinberg s Cubase Steinberg s Nuendo and Digidesign s Pro Tools GVI now includes a per instance memory usage meter when hosted in a VST or RTAS DAW application GVI now supports access to instrument help documentation when provided with a soundware library Th
3. content Previously using the Load menu to load a GSI file onto a MIDI channel was incorrectly performing a stack operation This has been fixed in 3 51 The FX button in the MIDI Mixer has been renamed to GP When illuminated this indicates that a GigaPulse encoded instrument has been loaded on that channel The associated pull down menu allows access to that GigaPulse UI It is still possible to access the GigaPulse UI for an encoded instrument via the GigaPulse toolbar icon when that instrument s MIDI channel is selected in the MIDI Mixer Known Issues In 3 54 For use with Ableton Live GVI should be installed into the Steinberg VST directory instead of the default TASCAM directory It is currently necessary to uncheck the Fast Bounce checkbox when bouncing a GVI track in SONAR It is not currently possible to open the ASIO control panel of the Echo AudioFire 12 from within the GVI Configuration window Patch changes do not work in SONAR 6 It is expected that a SONAR 6 update will fix this problem
4. is is accessed from the MIDI channel pulldown menu in the MIDI Mixer where the instrument is loaded If no help file is present this menu item will not be displayed GVI now includes a link to the product registration web page under the Help menu Registration gains the user access to informative newsletters special deals amp promotions and freebies The Loaded Instrument Viewer can be brought up by either selecting Loaded Instruments from a MIDI Mixer channel pulldown or by pressing the Instrument Viewer toolbar icon Once open instruments can be loaded onto any MIDI channel by drag amp drop NFX GVI now includes all four original NFX effect algorithms from GigaStudio These effects can be applied to any loaded instrument via a flexible new FX buss insert architecture These effects are e Chorus e EQ e Delay e Reverb To access these effects click the POWERED BY FX toolbar button to bring up the Giga Virtest tnstroment FX tab Bf moi mixer p ect Fe GigaPuise lf gt Piano Tone and Level Matching O gt Edit e Click Add FX Insert to add a new FX Insert Buss An FX Insert Buss creates a new output from GVI into which effects can be inserted Effects are added using the Add effect pulldown At the bottom of each FX Insert Buss is a pulldown allowing the output of that buss to be routed to a GVI output When hosted as a plug in this would go to a DAW input When running standalone this would g
5. nance Items in 3 52 In 3 51 certain audio interfaces that use buffer latencies that are not multiples of 128 could cause garbled audio This has been fixed in 3 52 Previously when running in standalone mode the output could become saturated under certain conditions This has been fixed in 3 52 Previously instruments within a GIG file could not be loaded when the Windows preference for hiding known file extensions was enabled Windows default This has been fixed in 3 52 Previously GVI could become unstable if Mute or Solo was pressed on the MIDI Mixer while receiving MIDI This has been fixed in 3 52 Previously GVI could become unstable if the UI was closed while loading instruments This has been fixed in 3 52 Maintenance Items In 3 51 An incompatibility with Sony s Acid 6 that caused no audio output from GVI when hosted in Acid 6 has been corrected Rare instances of GVI crashing when exporting to GSI have been addressed Previously when running in standalone mode it was not possible to change output channel selections after the sampler had been reset This has been fixed The filter Turbo Mode in the Quick Edit section of GVI is specific to the low pass filter Previously it was possible for the UI to present Turbo Mode enabled with a different filter selected Now when Turbo Mode is enabled the filter type is switched to low pass automatically The list of recently used files has been moved to below the list of factory
6. o to an audio interface s hardware output e Each effect can be enabled disabled using the ON OFF button in the upper left corner of the effect UI The last effect can be removed using the X in the upper right of its UI e FX Insert Busses can be routed to in the output routing pulldown of the MIDI Mixer NOTE When a GigaPulse instance is present from an encoded instrument an FX Insert Buss is automatically created for that GigaPulse instance Press the EDIT button to access the UI for that instance of GigaPulse For instruments with more than one GigaPulse process encoded both will appear in the grey list box Highlight one and press EDIT to access the UI for that instance Maintenance Items in 3 54 Previously when hosted in Pro Tools as an RTAS plug in GVI would not run at the correct rate in non 44 1k sessions This has been corrected in 3 54 Version 3 53 incorrectly showed 3 52 in the About GVI window Version 3 54 correctly shows 3 54 Maintenance Items in 3 53 The cause of rare cases of GVI instability on dual core systems at high polyphonies has been fixed in 3 53 Previously GVI could become unstable if switching GigaPulse encoded instrument presets while audio was being played This has been fixed in 3 53 Patch changes in Steinberg hosts are now reflected in the GVI UI In GVI 3 52 the Unload All and Unload Unused functions in the Loaded Instruments Viewer did not work This has been fixed in 3 53 Mainte

Download Pdf Manuals

image

Related Search

Related Contents

Casio 5213 Watch User Manual  QVS USB-201 User's Manual  J-3675-6, AutoMax Enhanced BASIC Language  Picasso Fish Hosting: Email Set Up Instructions  SGI® UVTM System Management Node Administrator Guide  

Copyright © All rights reserved.
Failed to retrieve file