1. Installation Drawing Ref No 0F9577 Ot 0400 30 109 roto 20R MENI me 335 ma 76 8 448 222222 SSS 45 1 o O GUARDIAN by Generac Power Systems Inc WEIGHT 1650 Ibs Generac Power Systems Inc e PO Box 8 Waukesha WI 53187 generac com 2008 Generac Power Systems Inc All rights reserved All specifications are subject to change without notice Bulletin 0179280SBY Printed in U S A 09 08
2. position switch auto off and manual e 2 wire start for any transfer switch e Communicates with the Generac RTS transfer switch e Built in 7 day exerciser e Selectable engine speed at exercise e Governor controller is built into the master control board e Temperature range 40 C to 70 C OL FITERE i csictezsscrsiscasteassaszssectessstasinaisettetasttsedeedesssesautisonbs Full flow spin on cartridge CRANKCASE CAPAC Y npin innate 4 Quarts ENGINE COOLING SYSTEM MRE uaa Aa ANAE WATER PUMP FAN SPEED esse acevcscstestestessrcasizesachestisniint tiered atartianscaantin dacheatecine S FAN DIAMETER sirarik aa a ai 22 inches FAN MODE Seina A aan Puller FUEL SYSTEM PUBL TY PE E E E A T Natural gas propane vapor CARBURETOR ninnan a ainininaataimunnannaains Down Draft SECONDARY FUEL REGULATOR essssesessecseesseessteesnsessesseesneensneennees Standard FUEL SAUT OFF SOLENOID cnannsrananssnaunann aan Standard OPERATING FUEL PRESSURE 5 14 H20 ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR 12V 30 Amp STATIC BATTERY CHARGER tisisscsissstsssescsticcssanssssissecsaantiisnsnssasissnaasesticesaanatticcies 2 Amp RECOMMENDED BATTERY iiirsiiisiiiinsisiiisians Group 24F 525CCA SYSTEM VOLTAGE seicccsiscisascassasstesanntitsisssstiiscassesviacesanessisinaatttinnneatiarsaaaestitis 12 Volts Rating definitions Standby Applicable for supplying emergency power for the duration of the utility power outage No overload capability is
3. 50 140 RATING All three phases units are rated at 0 8 power factor All single phase units are rated at 1 0 power factor STANDBY RATING Standby ratings apply to installations served by a reliable utility source The standby rating is applicable to varying loads for the duration of a power outage There is no overload capability for this rating Ratings are in accordance with ISO 3046 1 Design and specifications are subject to change without notice INTERCONNECTIONS oo00000 CONTROL PANEL TO ALTERNATOR N1 N2 23 NEUTRAL GENERATOR 194 CONNECTION CIRCUIT BOX 183 BREAKER 178 Battery Charger Input GROUND 120 Vot Neutral e o 200 Grd FRAME RAIL QT060 Utility In OOO NEUTRAL Transfer Switch To Generator Control Panel CIRCUIT BREAKER SIZE kW VOLTS AMPS LUG SIZE 60 24010 300 2 250 mcm to 2 1 0 or Ceao STUBUPAREA 1 600 mom to 4 See Install Dwg for 60 20830 250 2 250 mem to 2 1 0 or Dimensions 1 600 mcm to 4 60 24030 200 6 to 300 mcm
4. QT060 Liquid Cooled Gas Engine Generator Sets Standby Power Rating 60 kW 60 Hz UNIT ITTV AUC CCCL CTT GENERAC 2 4L ENGINE Turbocharged Aftercooled Gaseous Fueled STANDARD EQUIPMENT All input connections in one single area High coolant temperature shutdown Low oil pressure shutdown Low coolant level automatic shutdown Overspeed automatic shutdown Crank timer Exercise timer Oil drain extension Cool flow radiator Closed coolant recovery system UV Ozone resistant hoses Watertight state of the art electrical connectors FEATURES Innovative design and fully prototype tested e UL2200 Listed e Solid state frequency compensated voltage regulator Dynamic and static battery charger Sound attenuated acoustically designed enclosure Quiet test for low noise level exercise Acoustically designed engine cooling system High flow low noise factory engineered exhaust system Mainline circuit breaker Radiator drain extension Battery charge alternator 2 Amp static battery charger Battery and battery cables Battery rack Fan and belt guards Isochronous governor Flex fuel line Hour meter State of the art digital control system with R100 digital control panel Watertight electrical connectors Rodent proof construction High efficiency low distortion Generac designed alternator Vibration isolated from mounting base Matching Generac transfer switches engineered and tested to work as a system All co
5. Trani iaaea Hardened RIF WER UNV PES EEEE PRAT EE T Hydraulic NOTE Generator rating and performance in accordance with IS08528 5 BS5514 SAE J1349 IS03046 and DIN6271 standards GOVERNOR SPECIFICATIONS TRA EEEE E AE A E E E A E Electronic FREQUENGY REGULATION vecsciss desi Maen eis Geile lsochronous STEADY STATE REGULATION ssis esanian inion 0 25 VOLTAGE REGULATOR pire aala TEE E agentes Electronic SPOOd oseeessssssetssssseeetsssseeeetussseetitusssseeetusssseeitusssseeeiusssseeetunssseeeasss Yes SENSING Single Phase Dio pirinin m ea ea ae Yes REGULATION oiis eene eee iopet Acekard tintin Senate 1 FEATURES 3 sssessnasiachatiiainatiasnatitainatitasnatitannatitainaniaaiats V F Adjustable Kiwete ENGINE LUBRICATION SYSTEM naicators ooooeee ee _ OR Ty OIL PUMP GENERATOR FEATURES O Revolving field heavy duty generator O Directly connected to the engine O Operating temperature rise 120 C above a 40 C ambient O Insulation is Class H rated at 150 C rise O All models are fully prototyped tested CONTROL PANEL FEATURES O SEVEN LED INDICATOR LIGHTS CM ADDITIONAL FUNCTIONS e System ready e Utility sensing e Low fuel pressure e Delay on utility failure for engine start e Low battery e Engine warm up before transfer e Low oil pressure e Delay to retransfer to utility e High coolant temp low coolant temp Engine cooldown timer e Overspeed e Exerciser not set e Overcrank e Hour meter O INTERNAL FUNCTIONS e 3
6. available for this rating All ratings in accordance with BS5514 IS03046 and DIN6271 All ratings in accordance with BS5514 IS03046 IS08528 and DIN6271 GENERATOR OUTPUT VOLTAGE KW 60Hz 120 208V 3 phase 0 8 pf 120 240V 3 phase 0 8 pf 277 480V 3 phase 0 8 pf GENERATOR LOCKED ROTOR KVA AVAILABLE VOLTAGE DIP OF 35 Single phase or 208 240 3 phase 480V 3 phase ENGINE FUEL CONSUMPTION Natural Gas Propane Exercise cycle 25 of rated load 50 of rated load 75 of rated load 100 of rated load ENGINE COOLING Air flow inlet air including alternator and combustion air ft min System coolant capacity US gal Heat rejection to coolant BTU hr Max operating air temp on radiator C F Max ambient temperature C F COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz SOUND EMISSIONS IN DBA Exercising at 7 meters Normal operation at 7 meters EXHAUST Exhaust flow at rated output 60 Hz Exhaust temp at muffler outlet ENGINE PARAMETERS Rated synchronous RPM HP at rated KW POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3 for every 10 C above C 1 65 for every 10 F above F Altitude Deration 1 for every 100 m above m 3 for every 1000 ft above ft GUARDIAN by Generac Power Systems Inc CB Size 250 200 100 Natural Gas Propane ft hr gal hr cu ft hr 123 1 34 49 3 267 2 7 101 483 5 0 183 672 7 0 255 862 9 0 327 3 280 2 5 270 000 60 150
7. mponents easily accessible for maintenance Electrostatically applied powder paint GUARDIAN by Generac Power Systems Inc APPLICATION amp ENGINEERING DATA QT060 GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS TYPE sssssiscevesstesivvssscvcriccevertinacvsaistssicvesattbsveenstssicrsessdisanieertieaiauntdniadeansiaa Synchronous MAKE kj Generac ROTOR INSULATION iienaa a R ClassH MODEL 24 Liter STAT OPIN UIP TUON scsctteieiee taniptech lei eonrieceeerechlnnaiececeanbaaiines Class H CYLINDERS S ia 5d TOTAL HARMONIC DISTORTION s sssssssssssscssssessessssssssssssssssssssssssnsesseesessesseseseee 5 B erat TELEPHONE INTERFERENCE FACTOR TIF sc seesseessesssessessseessesseesneesnesseeeneess DISPLACEMENT issn ee vermin aT 2 4 Liter ALTERNATOR OUTPUT LEADS 3 PHASE ccccscsccscssescssescsseseesescesesceseseeseseseaes 4 wire BORE ss ghee pace ye E een ue Rep in yee ae am BEARINGS nn Sealed Ball S 3 94 ONN EERE AIAS REEERE EEIT EEEREN Flexible Disc COMPRESSION RATIO csccscsccscsscssssescsseseesesessescscsssscsesscsessesesscsecscsesscsesscssscaeees 8 5 1 LOAD CAPACITY STANDBY RATING ccccssscscssssssssssscssssccssssessssecsssseessseessessens 60 kW INTAKE AIR SYSTEM cscscscocisteersssschssicasastccertascsiacciracesbsaeeteists Turbocharged Aftercooled EXCITATION SYSTEM cccscscsscscsscsssscssscesssesssscssssessssessssesessesscsessssesesseescseeesseneess Direct WAIVE SEATS iiics sereen r ena a aeaa aE iian aarte E eea