Home

Guardian Technologies PUREGUARDIAN H1000 User's Manual

image

Contents

1. 5 Attach the tank to the body of the unit and plug in 6 Press the button to turn on E 6 READ AND SAVE THESE INSTRUCTIONS MAINTENANCE OPERATING INSTRUCTIONS e Always unplug the unit before servicing it in any way Do not submerse the unit in water or allow water to enter the inside of the unit INSIDE THE BODY OF THE UNIT Pour excess water out ofthe unit Wash out the unit with fresh water using the cleaning brush and a soft cloth as needed OUTER SURFACE OF THE UNIT Wipe the surface of the unit with a soft damp cloth if needed WATER TANK Fill water tank with clean water and shake to remove water scaling ULTRASONIC DISK Remove the water tank Figure 1 and use the enclosed cleaning brush regularly to remove build up and deposits from this are Figure 2 Do not use any detergents or soap as this may damage the ultrasonic disc This may also disperse detergent or soap residue with mist causing bodily harm Do not scrub with finger tips or any sharp objects as this may cause damage to the ultrasonic disc If there is red color build up on ultrasonic disk gently clean with soft cloth and 1 2 drops of white vinegar Rinse with clean water Clean the disk with the brush only No other cleaning tool should be used Brush only Fig 2 Figure 1 Figure 2 STORAGE e Fully dry the inside and outside of the unit before storing it e DO NOT leave water in the unit e Store in a co
2. Communication interference Although tested it may affect these devices If the humidifier is found to interfere separate the device and or the humidifier Conduct only the user maintenance found in this manual Other maintenance and servicing can cause harmful interference and can void the required FCC compliance Guardian Technologies LLC 7700 St Clair Avenue Mentor Ohio 44060 1 866 603 5900 www guardiantechnologies com E 9 02007 Guardian Technologies LLC
3. er securely Do not put water in the spout Do not damage the adapter cord Do not place adapter cable over objects Be careful not to get water in or on the power cord adapter or where it connects to the product Do not touch water tank during operation Do not submerse the unit in water or pour water on the unit When emptying water from water tank pour on drain side Be careful not to put any detergent any oils any chemicals into water reservoir and or tank Do not place this product on cloth carpet or vinyl This may block air inlet Unplug the adapter when unit is not in use for an extended period of time and or when no one is present in the home Do not drink the water from the tank Do not cover the spout with a cloth or your hand and do not use without the spout Do not keep water in the tank when not in use for an extended period of time Do not put anything in the tank Do not use the product near a gas oven range Use clean or distilled water in the tank Do not place anything on water tank or damage product by dropping E 5 READ AND SAVE THESE INSTRUCTIONS DIRECTIONS FOR USE OPERATING INSTRUCTIONS Make sure the unit is unplugged 1 Separate the tank from the body of the unit the left 3 Pour cool clean water directly into 4 Close the tank lid turning it the tank Do not pour anything but to the right water into the tank
4. guardian technologies USE amp CARE INSTRUCTIONS Table Top Ultrasonic Humidifier Guardian Technologies LLC Model No H1000 English E 1 7700 St Clair Avenue Mentor Ohio 44060 3 Year Limited Warranty French F 1 1 866 603 5900 www guardiantechnologies com www guardiantechnologies com Spanish S 1 1 866 603 5900 REVO810 Date Purchased month year 02007 Guardian Technologies LLC E1 READ AND SAVE THESE INSTRUCTIONS PRODUCT SPECIFICATIONS AND PARTS SPECIFICATIONS Model Number H1000 Humidifying Mode Ultrasonic Power Supply AC120V 60Hz Adapter AC120V AC 24V Power Consumption 18W Humidity Capacity About 110cc hr Tank Capacity 0 23 gallons Successive Humidity Hours 8 hours or more depending on environmental conditions Dimensions Width 7 9 inches Height 8 5 inches Depth 3 5 inches Weight 1 32 pounds Not including packing adapter PARTS HUMIDITY SPRAY SPOUT Ultrasonic Humidifier POWER BUTTON POWER PLUG E 2 CLEANING BRUSH READ AND SAVE THESE INSTRUCTIONS FUNCTIONS AND FEATURES Water Shortage Indicator When the unit is low on water the Refill Indicator LED on the body will change from green to red and the unit will shut off Simply add more water to continue use Mist Director The mist director can be selected through 360 by turning the spout Silver Clean Technology Unlike other humidifiers that grow sllimy mold and mildew the Ultrasonic Humidifier uses Silver C
5. lean technology embedded in the tank to fight the growth of mildew and mold on the surface of the water tank Cleaning Brush Storage E 3 READ AND SAVE THESE INSTRUCTIONS WARNINGS Failure to comply with the warnings listed above may result in electric shock or serious injury AN This product should be used only in accordance with the specifications outlined in this manual Usage other than what has been specified here may result in serious injury Disassembly repair or remodeling by an unauthorized person may result in serious harm Do not use if adapter plug is damaged or loose Keep this product out of the reach of children and away from pets Be careful not to put water in the humidity spout Before filling or cleaning the unit make sure it is unplugged Once the humidifier has been turned on do not move it and do not disassemble the water tank Do not move when in operation Do not remove the water tank from the unit while it is on Do not handle the adapter plug with wet hands Do not excessively bend twist or pull the adapter cable Avoid placing this product where the humidity is pointed directly at an object Do not directly inhale the humidity Do not place this product on a sloped or unstable surface When not in use unplug the unit Do not fill the water tank with hot or boiling water Do not use this product in direct sunlight or near a gas stove or heater If the water tank becomes cracked or damaged do
6. not use Do not keep this product running for an extended period of time Do not clean the unit or water tank with detergents or chemicals of any kind Do not use this product near any other electronic device Do not cover the humidity opening at any time during use Do not use this product near a sink Do not place this product on an absorbent surface Do not pour anything but water into the water tank Children cannot recognize the hazards associated with the usage of electrical appliances For this reason always supervise children when they are near the humidifier If the mist comes in contact with the floor prior to evaporating the floor surface may be damaged We do not accept any liability for damage in the case of the unit being placed incorrectly The use of water additives such as ethereal essential oils fragrances eucalyptus water condi tioners etc will damage the appliance materials and as a consequence the whole unit Any use of such additives will void the manufacturer s warranty IMPORTANT Neither humans nor animals can hear the high frequency vibrations Failure to comply with the warnings listed above may result in electric shock or serious injury E 4 READ AND SAVE THESE INSTRUCTIONS WARNINGS Failure to comply with the warnings listed above may result in electric shock or serious injury Do not tilt or move the unit when unit is plugged into outlet When unplugging from outlet hold humidifi
7. ol dry place E 7 READ AND SAVE THESE INSTRUCTIONS TROUBLESHOOTING GUIDE PROBLEM Water vapor amp humidity are not produced Air blows but water vapor is not produced Humidity level is low The humidity has a bad smell White dust forming on nearby furniture E 8 SOLUTION Power Plug Unplug and then try again Power Failure When the power is returned try again Make sure the water is in the tank and the tank is correctly attached Clean the ultrasonic disc and its periphery Excessive Water Remove a certain amount of water from the tank Detergent residue and or oil ingredients from cosmetics etc may be in tank wash out tank and try again Clean the ultrasonic disk and its periphery If you use hard water replace with softer water The surface of the ultrasonic disc is dirty Clean the ultrasonic disc and its periphery The water in the unit is too cold Replace with cool but not cold water Boil clean water and let cool Use water after 24 hours Poor maintenance or dirty water Clean product thoroughly and fill with fresh water Hard water deposits a certain amount of dust Use distilled water if this becomes a nuisance READ AND SAVE THESE INSTRUCTIONS LIMITED WARRANTY To the consumer Guardian Technologies LLC warrants this product to be free of defects in materials and workmanship commencing the date of the original purchase Save your original sales receipt to validate start of
8. warranty period If this product should become defective within the warranty period we will repair or replace any defective parts free of charge The complete machine must be delivered pre paid to any authorized Guardian Technologies LLC warranty service center Please include complete information on the problem day of purchase copy of original sales receipt and your name address and telephone number If you are not near a warranty station call the factory for assistance in the US and Canada at 1 866 603 5900 Use only genuine Guardian Technologies replacement parts The warranty does not include unusual wear damage resulting from accident or unreasonable use of the product This warranty does not cover unauthorized repairs This warranty gives you specific legal rights and you may also have other rights other rights may vary from state to state in the U S A We consider the registration process important to ensuring superior service to our customers however submitting this card to Guardian Technologies LLC is optional and does not affect your rights to utilize this warranty according to the conditions stated above If you have any questions or comments about our product call toll free at 1 866 603 5900 or send comments to ATTN Customer Service Guardian Technologies LLC 7700 St Clair Avenue Mentor Ohio 44060 This product has been tested and complies with the requirements C for Federal Communications Commission Part 18 for Radio TV