1. 3 3 Initial Start up Procedure The VGS2 PC system has been designed to be installed on the cold water line only The presence of small air bubbles in the water system may occasionally give the water a milky appearance but air bubbles will not affect water quality or taste Initially filtered water may appear cloudy due to the release of air trapped within the filters and throughout the system Dependant upon your use of the system this condition should disappear within a few days following system installation Always perform the following start up procedure when starting your VGS2 PC system for the first time after a storage period 1 Shut off the main water supply valve 2 Mark and drill mounting location for the faucet 3 Install faucet with the hardware provided 4 Mount the VGS2 PC system to the inside cabinet wall Please ensure that when mounting the system a proper sized screw is utilized so as not to penetrate the cabinet wall Install adapter valve on cold water line and ensure plumbing for sink faucet is correctly secured to the top of the adapter Hook up inlet water connections from the adapter valve to the filter inlet port and outlet water port to the base of the faucet using the 1 4 tubing provided 7 Confirm that all of the plumbing connections are secured and partially open the main water supply valve 8 If no leaks are visible fully open the main supply valve Ch
2. Dual Stage Water Filtration system Syst me de filtration d eau Double tape Sistema de filtrado de agua de etapa doble Use amp Care Guide Guide d utilisation et d entretien Manual d uso y cuidado VGS2 PC Greenway VITAPUR VGS2 PC Home Products 1 SAFETY INSTRUCTIONS 4 eee eee eee 2 2 PRODUGT OVERVIEW caca ci cena eens ei 2 2 1 ABOUT YOUR SYSTEM ne m res tre 3 3 INSTALLATION INSTRUCTIONS 44 444 444 sus eee eee anna 4 3 1 ACCESSIBILITY ORIENTATION amp FITTINGS 4 322 INSTALLATIONS bide de de dade 4 3 3 INITIAL START UP PROCEDURE wee eee cece ence eee eee eee 4 4 SERVICE AND 4 4 1 ACCREDITED SERVICE TECHNICIAN pu cee ue eee eee ee eee eee eee 4 4 2 FILTER REPLACEMENT a ae teehee etek ete dee whe baad whe bade where aes 5 4 3 REPLACEMENT COMPONENT ORDERING INFORMA
3. RANTIE LIMIT E DU FABRICANT 7 1 INSTRUGCIONES DE SEGURIDAD ex aw en ee eee 2 2 VISION GENERAL DEL PRODUCTO cccccccccccccccceecuaceeeeesnaeeeenenaneenenns 2 2 1 ACERCA DE SU SISTEMA wee eee eee eee eee eee eee eee eee eee 3 3 INSTRUCCIONES DE INSTALACI N uuseeeuueeee eee eee eee 4 3 1 ACCESBILIDAD ORIENTACI N Y ACCESORIOS 4 INSTALACI N soror E penr we ee ee We We ee ei 4 3 3 PROCEDIMIENTO DE PUESTA EN MARCHA INICIAL eee 4 4 SERVICIO Y MANTENIMIENTO 2 ore ee ie er ee er wre eed ee ee eae ee ee 4 4 1 T CNICO DE SERVICIO CALFICADO a uae eee ee eee eee ee ence eee eee eee mn neue mms 4 4 2 REEMPLAZO DEL FILTRO 5 4 3 INFORMACION SOBRE LOS PEDIDOS DE COMPONENTES DE REEMPLAZO 5 6 REPARACI N DE AVER AS ccc cece cc cccccccecccuacceeeenaaeeeeennneeeennnanenntngs 6 5 GARANT A LIMITADA DEL FABRICANTE 7 Thank you for choosing the vitapur VGS2 PC to meet your water treatment neeeds We have carefully engineered your Dual Stage Water Filtration Sys
4. TION 5 6 TROUBLESHOOTING GUIDE deu 6 5 MANUFACTURER S LIMITED WARRANTY 000ce cece ue eu 4 7 1 INSTRUCTIONS DE S CURIT ccccccccccccccccccccceecauceeeuenaeeeeennaaeenennnaas 2 2 APERGU DU PRODUITES SSSR Rd 2 2 1 1 VOTRE SYST ME SESE eee SRE S ESE ae EERE ERE EER SURE ee bees 3 3 INSTRUCTIONS 0 4 3 1 ACCESSIBILIT ORIENTATION MONTAGE 4 2 INSTALLATION oree asken LUE 4 3 3 PROCESSUS INITIAL DE MISE EN MARCHE eee eee eee eee eee eee eee 4 A SERVICE JET ENTRETIEN 2 22 cacy ooo 5 0 5 5 2055 one obo 22 2 4 4 1 TECHNICIEN DE SERVICE ACCREDITE pa eeu eee eee eee eee eee een uns 4 4 2 REMPLACEMENT DES FILTRES wee uu eae e eee eee eee eee NENEN NECES CESES SECES SENESTRA 5 4 3 COMMENT COMMANDER DES PI CES DE RECHANGE 5 6 GUIDE DE DEPANNAGE 6 5 GA
5. at 1GPM VGS2 PC leaking water Misaligned or cross threaded ports Reinstall to ensure a good solid connection with ports Excessive water pressure beyond 80 psi Install pressure regulator ahead of system Water Hammer causing pressure spikes Install a Water Hammer Arrestor in system Water is milky Small air bubbles are trapped in water Leave tap on for short time Air purging from new filters system Find source of air bubbles and correct System is vibrating Not mounted securely Secure fasteners Water Hammer causing vibrations Install a Water Arrestor in system Outlet water has bad taste Filters not installed Ensure filters are in position Filter housings not seated properly Ensure that the filters are correctly seated in the housing and that the housing are seating properly Testing source indentification Testing should be conducted to additional pre treatment required determine cause of bad taste Additional pre treatment may be required Outlet water is dirty particulate matter Filter not installed Ensure filters are in position or has undesirable color Filter s housing s not seated properly Ensure the filters are correctly seated in the housing and that the housing are seating properly Water Hammer Sudden closure of a control valve or stopping of a pump produces excess pressure in a pipeline The hydraulic engineer water supply designer and pumping system oper
6. ator have the responsibility to ensure the surges due to Water Hammer are within acceptable limits and can be dampened as quickly as possible Note If you experience trouble with your system other than the symptoms described above please visit www greenwayhp com or contact the Customer Service Department at 1 866 253 0447
7. ce on the unit Always drain all water from the unit cap the Inlet and Outlet Ports and drain and disconnect all plumbing lines if temperatures should fall below freezing 0 C 32 F The VGS2 PC filtration system is designed for use with microbiologically safe water only Do not use on water that is microbiologically unsafe or of unknown origin without adequate disinfection before or after the system 2 Product Overview The vitapur Dual Stage Water Filtration System has been engineered to rigid standards and has been quality inspected at the factory prior to packaging Please review this manual in its entirety for a detailed system explanation and ensure that the following components accompany this system Q Filter Housing 4 1 4 Tubing Sediment Adapt Particulate Filter QO ganien iye Carbon Block Filter Faucet Faucet Hardware To ensure system performance all replacement components must be purchased directly from an authorized dealer or directly from Greenway Home Products The use of components purchased from other sources will void the warranty and will potentially cause the system to function in a lesser capacity than intended Filter cartridges should be replaced every 4 6 months or when the pressure drop through the cartridges inhibit water flow to the point where pressure losses are being experienced The VGS2 PC is intended for the supplemental treatment of disinfected public drinking water or other d
8. eck for leaks 9 Slowly open the adapter supply valve and check system for leaks 10 Open the faucet and flush the filtration system for 5 minutes 11 Your VGS2 PC system is now ready for use D 4 Service and Maintenance 4 1 Accredited Service Technician Whenever you require assistance visit www greenwayhp com or please call the Customer Service Department at 1 866 253 0447 4 2 Filter Replacement Filter cartridge life varies depending on usage and or water conditions Changes in taste color and flow of the water being filtered indicate that the cartridge should be replaced It is recommended that the filter cartridges be replaced every 4 6 months Replace sooner if water pressure at faucet begins to drop noticeably or cartridge fails to perform satisfactory WARNING The filters used in the VGS2 PC system are not universal filters Use of any other filter in the system will void the warranty Replacement filters model VGSRF2 PC ED Close Supply Valve Untwist 4 Replace Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system Procedure for replacing filter cartridge 1 Turn off the water supply to the system 2 Depress the red pressure relief buttons on both filter housings a small amount of water may come out of the release valve when the pressure is released 3 Using both hands loosen the filter housing in the cl
9. ockwise direction 4 When the filter housing is turning hold onto it with both hands while backing the housing off the threads The housing filled with water and a wet filter is heavy be cautious and ensure that you are adequately positioned to support the weight 5 Remove the old filter and dispose in the trash Used filters are not considered hazardous waste 6 Empty the housing of water and insert the new filter cartridge Make sure that the o ring on the filter housing has not fallen off when dumping the excess water or removing the old filter 7 Attach the filter housing onto the system 8 Lightly tighten the filter housing back into position with your hands 9 Refill the system by opening the inlet water line just enough to fill the housings with water 10 Check the system for leaks 11 If no leaks are evident open the inlet water line completely and recheck for leaks 12 Flush the system for a minimum of 5 minutes prior to use 4 3 Replacement Components Ordering Information Please contact the Customer Service Department in Canada 1 866 253 0447 in the USA 1 866 282 0533 Quantity Part description Filter Head 1 4 Tubing pt 1 Adapter Supply Valve 1 1 Faucet including hardware Lt Dual Pack Replacement Filters N A sediment amp carbon block 5 5 Troubleshooting Guide Problem Possible Cause Suggested Solution Pressure Drop Filter s clogged Replace filter cartridge More than 40 psi loss
10. rinking water which has been tested and deemed acceptable for human consumption by the provincial state or local health agency having jurisdiction The VGS2 PC should not be used on water that is microbiologically unsafe or of unknown origin without adequate disinfection before or after the system If you will be using an untreated surface water or groundwater source rather than a municipal supply source that has been deemed acceptable for human consumption by the provincial state or local health agency having jurisdiction additional pre treatment of the water prior to the VGS2 PC may be required The filtration provided with the VGS2 PC is 5 um nominal and is not suitable for the reduction of protozoan cysts 2 1 About Your System Specifications VGS2 PC Flow Rate Range 3 8 LPM 1 GPM Unit Dimensions L x W x H 26 7 10 5 13cm 5 125 33 3 13 125 Shipping Weight 2 1 kg 4 6 Ibs Operating Pressure Range 0 60 PSI Feed Water Temperature Range 41 100 F 5 37 7 C Unit Volume 1 4 L 0 37 Gal Inlet Port Size 1 4 Quick Connect Outlet Port Size 1 4 Quick Connect 3 Installation Instructions 3 1 Accessibility Orientation amp Fittings Mount the VGS2 PC in a location that provides ample space for replacement of filter cartridges It is recommended that you maintain at least 6 15 cm of clear space below the VGS2 PC for this purpose 3 2 Installation 1 Drill amp Mount
11. tem to provide you with years of touble frree operation 1 Safety Instructions The installation of this system must be in accordance with all provincial state and or local laws and regulations regarding plumbing services Installation by a certified plumber is recommended Always comply with the following warnings and safety instructions to prevent bodily injury or property damage Do not attempt to install operate clean or perform routine maintenance on your VGS2 PC system unless you have first read and understood all of the warnings and safety instructions that are contained in this manual and on the labels that are affixed to the VGS2 PC system Do not attempt to operate the VGS2 PC system if it has been visibly damaged e g due to abuse in shipping or if it may have sustained damage e g if the unit has been dropped To prevent faulty operation of the system inspect it carefully to ensure it is free of leaks and physical damage before using Never start the VGS2 PC system e g after the initial installation before confirming that the exterior is dry and that there are no visible leaks To prevent damage to the unit always install the VGS2 PC system indoors where it will not be exposed to the elements Always install and operate the unit in an environment where both the air and water temperatures will normally range between 41 F 5 C and 100 F 37 7 C Always stop the inlet water flow before performing any maintenan