Graham Field 707A-INS-LAB-RevD11 User's Manual

image

Contents

1. does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to GF Health Products Inc The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understandings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any representation assertion guarantee warranty collateral contract or other assurance except those set out in this document Labtron Digital Blood Pressure Monitor 18 BLOOD PRESSURE MEASUREMENT LOG Pulse Body Condition Labtron Digital Blood Pressure Monitor 19 USA Corporate Headquarters GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 telephone 770 368 4700 fax 770 368 2386 GRAHAM FIELD www grahamfield com 707A INS LAB RevD 11 2011 GF Health Products Inc
2. replace the four AAA batteries F T oriented as shown by battery compartment diagram into the battery compartment 3 Replace the battery cover Ensure that the battery cover is securely fastened Info Ensure that the batteries are correctly installed Incorrect installation will prevent the device from operating BLOOD PRESSURE Blood Pressure is a measure of the blood s pressure in the circulatory system which changes constantly during the course of the cardiac cycle Blood pressure readings report two values The higher reading systolic pressure shows the highest pressure Labtron Digital Blood Pressure Monitor 5 in the arteries occurring when the heart contracts The lower reading diastolic pressure shows the lowest pressure in the arteries which occurs right before the heart contracts Blood pressure readings are written with the highest value first then the lowest value Readings of 120 80 are considered to be normal with high blood pressure being defined as a systolic pressure which is 140mmHg or more at rest and a diastolic pressure which is 90mmHg or more at rest Only a patient s physician is qualified to determine whether the readings obtained are normal for that person Preparing to measure blood pressure 1 Blood pressure fluctuates continuously throughout the day To consistently track your blood pressure try to take your blood pressure at the same time each day 2 Relax and remain s
3. at within cuff Indication Err displays cuff pressure releases then 0 pressure displays Err P Cause Excessive arm movement or talking during measurement menor osinatobtan pusere OO correctly positioned seek medical attention immediately DE Batteries are exhausted Replace with four new AAA alkaline batteries Labtron Digital Blood Pressure Monitor 14 General troubleshooting Recommended Action Nothing appears Ensure that batteries are correctly oriented in battery holder polarity in LCD matches battery case placement indicators No measurement Ensure that cuff is positioned correctly occurs Go over measurement procedure measure again Blood pressure Ensure that user and cuff are positioned as instructed measurements are Rest your arm on a table so that the cuff is level with your heart during too high or measurement too low Remain seated and still during entire measurement period Refrain from hand and body movements during measurement Blood pressure Your blood pressure can fluctuate considerably throughout the day All measurements of the following factors can influence your blood pressure vary Emotional state Daily activities exercise Smoking Drinking alcoholic beverages Eating Taking certain medications Labtron Digital Blood Pressure Monitor 15 SPECIFICATIONS Digital Blood Pressure 707A adult size cuff fits 7 5 in 12 2 in 19 31cm arm Monitor Model 707A X la
4. dolor A Graham Field Brand Item 707A 707AX 707AC Digital Blood Pressure Monitor with Manual Inflation amp Automatic Deflation User Manual Read this manual before operating the Labtron Digital Blood Pressure Monitor Save this manual for future reference 707A INS LAB RevD11 Itt CONTENTS SAFETY GUIDELINES PLEASE READ BEFORE USE 4 eese ennt 3 liz 3 FEATURES s 4 BATTERY INSTALLATION REPLACEMENT ee 9 BLOOD PRESSURE enero ee ee 9 PREPARING TO MEASURE BLOOD PRESSURE eese nentes 6 MEASURING BLOOD PRESSURE s eeseeseeseeeeeeeene nte cnn c nro narran cnn na cancer cnn 9 MAINTENANCE coi Nine ener omg 13 TROUBLESHOOTINC nU REX NI MD ND MI EI DTE 14 ERROR INDICATORS mem 14 GENERAL TROUBLESHOOTING oooonccoccccccccnncnccnncnonannncnnoncn cnn cnn nennt nn nana canaria 15 SPECIFIGATIONS n ge a a a A AES aaO VAE 16 Loo pfe 18 BLOOD PRESSURE MEASUREMENT LOG nr rnnrsnnernnennnennennsnesneneneesnnennenes 19 Graham Field and Labtron are registered trademarks of GF Health Products Inc Packaging warranties products and specifications are subject to change without notice GF Health Products Inc is not responsible for typographical errors Labtron Digital Blood Pr
5. essure Monitor 2 SAFETY GUIDELINES PLEASE READ BEFORE USE A Important Read and understand these instructions before using the Labtron Digital Blood Pressure Monitor If you do not understand any part of these instructions contact your medical professional or Graham Field dealer for direction in the use of this product A WARNING If components are damaged or missing contact your Graham Field dealer immediately DO NOT use substitute parts Z WARNING GF Health Products Inc assumes no responsibility for any damage or injury caused by improper installation or use of this product INTENDED USE The Labtron Digital Blood Pressure Monitor is intended to measure arterial blood pressure This device is intended for use by adults and not for use by children except under the supervision of an adult This device is not intended to replace regular medical examinations Review your procedure for using this monitor with your physician who is the only person qualified to interpret blood pressure monitor results Labtron Digital Blood Pressure Monitor FEATURES Main features of the Digital Blood Pressure Monitor referred to in this manual are shown in the picture at right exhaust valve button cuff hose E titel Lm button Digital Blood Pressure Monitor Labtron Digital Blood Pressure Monitor 4 BATTERY INSTALLATION REPLACEMENT 1 Slide the battery cover off in the direction of the arrow o 2 Install or
6. he arm the cuff is properly secured If you are ku icis unable to fit the cuff as described above a smaller or larger cuff should be used P Ca Labtron Digital Blood Pressure Monitor Measuring blood pressure Symbol key LCD symbols you may see during measurement y Deflating Inflating E r r Measurement error DE Low battery 1 Ensure that cuff is properly placed and that you are positioned as described in previous paragraphs 2 Press the ON OFF button All LCD symbols will appear momentarily If a downward arrow symbol displays press the exhaust valve button see earlier labeled picture located between the inflation bulb and the tube to release the residual pressure from the cuff Labtron Digital Blood Pressure Monitor 9 Info The low battery symbol will also appear at this time while the monitor checks the power level This does not indicate that the batteries are low unless the low battery symbol remains on continuously 3 After 0 displays pressurize the cuff by squeezing the bulb until the pressure value displayed is 50mmHg above your usual systolic pressure If you do not know your usual systolic pressure squeeze the bulb just until 200mmHg displays The cuff will automatically deflate after you stop pressurizing the cuff If an upward arrow symbol displays you must inflate the cuff to a higher pressure than you did the first time If an upward arrow does not display the m
7. onitor is taking your measurement Remain calm and still to avoid causing any measurement error The systolic pressure diastolic pressure Systolic Diastolic ill di i 10 m and pulse will display in the format shown ic n H n at right The device will completely deflate iun e when measurement is finished To accelerate Pulse rate deflation press the exhaust valve button Labtron Digital Blood Pressure Monitor 10 Info To stop measurement in progress for whatever reason press the exhaust valve button to release the pressure and turn off the device Info If during measurement the power drops to an insufficient level the device will end the measurement and display the low battery symbol Replace the batteries and repeat the measurement Info If the device cannot detect your pulse it will end the measurement Wait several minutes ensure that you and the cuff are positioned properly and try again 6 The device will automatically shut off three minutes after completing a reading or you may turn it off manually by pressing the ON OFF button Labtron Digital Blood Pressure Monitor 11 7 If performing measurement for the first time repeat the measurement two or more times to ensure that you and cuff are positioned correctly and that results are accurate and consistent Record your results there is a log provided with examples at the end of this manual for this purpose Always check with your physician to ensure
8. rge adult size cuff fits 11 8 in 17 7 in 30 45cm arm 707A C small adult size cuff fits 5 1 in 7 9 in 13 29cm arm Por ET CE Reference method for Auscultatory measurement clinical trials Weight Approximately 75 Ib 340g without batteries Labtron Digital Blood Pressure Monitor 16 Specifications continued Environmental 50 F 104 F 10 C 40 C 10 85 RH conditions Storage amp 14 F 140 F 10 C 60 C 10 95 RH transport Standard cited EN 1060 1 Noninvasive blood pressure measuring equipment general requirements Noninvasive blood pressure measuring equipment supplementary requirements for electromechanical blood pressure measuring systems EN 60601 1 Safety requirements for medical electrical equipment EN 60601 Electromagnetic compatibility and safety for medical 1 2 electrical equipment EN 14971 Risk analysis for medical devices Specifications are subject to change without notice Labtron Digital Blood Pressure Monitor 17 WARRANTY GF Health Products Inc Graham Field warrants the Labtron Digital Blood Pressure Monitor Model 707A 707A X 707A C for a period of one year for defects in workmanship and materials If a product is deemed to be under warranty GF Health Products Inc shall provide at its option 1 replacement of any defective part or product or 2 a credit of the original selling price made to GF Health Products Inc s initial customer The warranty
9. that readings are performed correctly If you have concerns or questions about your results always contact your physician Only your physician is qualified to analyze blood pressure Labtron Digital Blood Pressure Monitor 12 MAINTENANCE A NOTICE To prevent product damage please follow these recommended care and maintenance instructions Do not drop or pull excessively on monitor components or subject them to strong impact Do not use monitor close to any device with a strong electrical field such as television microwave oven X Ray equipment etc Never inflate cuff above 300mmHg Never inflate cuff unless it is positioned on an arm Do not expose the monitor components to direct sunlight high temperature or high humidity Do not put any part of monitor in contact with sharp objects which could pierce the material and cause damage Do not dismantle or disassemble monitor components Cleaning Wipe off all components with a clean dry cloth Do not use solvents or other petroleum based cleaners Do not press cuff with a hot iron Storage Always deflate the cuff completely before storage Remove the batteries when the device is to be stored for extended periods of time Info Removing the batteries will erase all readings in memory Labtron Digital Blood Pressure Monitor 13 TROUBLESHOOTING Error indicators a Indication Cuff pressure reaches 330mmHg Err 338 Twisted bladder inside cuff Ensure that bladder lies fl
10. till for 5 to 10 minutes before a blood pressure measurement and between blood pressure measurements 3 Refrain from eating smoking and drinking especially alcoholic Labtron Digital Blood Pressure Monitor 6 beverages before a measurement 4 Remove any clothing on the upper arm to place the cuff directly on the skin Constriction of the upper arm by clothing or a rolled up sleeve as shown at excessive right may cause an inaccurate reading remove any constriction constricting garments 5 Sit down in a chair with back support and place both feet on the floor 6 Extend the arm from which the blood pressure will be taken to the front or side Rest your hand palm up on a table as shown at right Jl Info Place the cuff at the same level as your heart to obtain accurate measurements Your heart is located slightly to the right of your left armpit Labtron Digital Blood Pressure Monitor 7 7 Attach the cuff Hold the area of the cuff where y the hose exits the cuff firmly against the inside ug of the bare upper arm directly over the brachial artery and the bottom of the cuff approximately Y one inch 2 3cm above the elbow as shown in the SCA third picture at right Never place the cuff over clothing Pull the opposite end of the cuff snugly around the arm and secure with the hook and loop fastener The cuff should be snug but not too tight e If one or two fingers can fit between the cuff and K t