Home
Graco Trabon MSP Modular Divider Valves User's Manual
Contents
1. L10102 Item Description Part No Old Part No 8 Tie Rod 3 required 3 Section 557731 527 001 930 4 Section 557732 527 001 940 5 Section 557733 527 001 950 6 Section 557734 527 001 960 7 Section 557735 527 001 970 8 Section 557736 527 001 980 9 Tie Rod Nut Only 3 required 556371 410 440 010 10 Valve Block Mounting Screws 556513 419 140 070 11 Piston Enclosure Plug 99 716 527 000 232 12 Piston Enclosure O Ring 556568 422 210 040 13 Indicator Port Plug 557776 527 300 840 14 Indicator Port Plug O Ring 556567 422 210 030 15 MSP Buna N O Rings 556540 422 010 060 MSP 70 Duro Viton O Ring 557721 527 000 810 16 Valve Block Mounting Screw for Crossport Singling 556514 419 140 080 Plate 17 Outlet Check Ball 556327 401 030 020 18 Outlet Check Spring 557737 527 001 910 Special Inlets Valve State Description Part No Old Part No Zero Leak 115 VAC 3 Pin Brad Harrison Connector N C 1 4 18 NPSF 563460 527 004 320 N C 9 16 18 SAE 563468 527 005 200 Replacement Coil 557226 492 120 206 Zero Leak 24 VDC 3 Pin Brad Harrison Connector N C 1 4 18 NPSF 563464 527 004 870 N C 9 16 18 SAE 563467 527 005 180 N C 1 4 BSPP ISO 1179 563082 463 920 720 Replacement Coil 557225 492 120 205 Zero Leak No Coil order separate 563462 527 004 770 Shunt Shut Off 115 VAC 3 Pin Brad Harrison Connector N O 1 4 18 NPSF 563452 527 003 660 N O 9 16 18 SAE 560953 5
2. SINGLE VALVE W CYCLE PIN RIGHT RH OUTLET SINGLE VALVE W CYCLE PIN RIGHT LH OUTLET TWIN VALVE W CYCLE PIN LEFT SINGLE VALVE W CYCLE PIN LEFT RH OUTLET SINGLE VALVE W CYCLE PIN LEFT LH OUTLET ACcCrvaI Orns CROSSPORTING OPTION CR RIGHT HAND SIDE CL LEFT HAND SIDE CB BOTH SIDES Ordering Example L10102 Notes 1 Right Left Hand determined when viewing front of divider valve assembly Divider valve assembly placed on flat surface with inlet at top 2 Valves are specified starting from inlet section 3 When valve is crossported its outlet is plugged and output is diverted to next valve away from inlet 4 Last valve in divider assembly farthest from inlet cannot be crossported 5 Single valve can be crossported on one side only 6 When valve is a single only one outlet in its subplate can be used other outlet must be plugged 7 Cycle pins are available on MS 20 25 30 35 and 40 valves only 8 All divider valve assemblies must have a minimum of 3 working valves 9 Bypass block cannot be supplied on divider valve with 3 subplates Bypass block is not a working valve 10 Divider systems should be limited to first and second stages only Third staging is not recommended Refer to Trabon Bulletins L20101 L20105 and L20115 for further information on system design Caution O Hyd Pressure O LUBRIQUIP MS 30 T F OPEN O OPEN LUBRIQUIP
3. is available to eliminate a piston section or provide for added lube points in the future NOTE When bypass sections are used the Divider Valve assembly must have a minimum of 3 working sections in addition to one or more bypass sections Brits bet x Tier ropa Page 2 MSP Modular Divider Valves L10102 Improve matchup of lube delivery and machine usage Special Inlet Sections e Allow zoning of large systems served by single pump and reservoir e Choice of inlet port activation electric or pneumatic e Simpler to install add or remove points e Choice of SAE NPSF BSPP ISO 1179 or metric ISO 6149 connection These versatile inlets provide positive series progressive lubrication for extended lines and systems You easily match lube delivery to machine usage bypass machinery that s not Currently in use and get reliable start up testing monitoring and fault detection HEADER LINE TO CONTROLLER TYPE dC Zero Leak Inlet Shut Off A two way valve that can be used with either continuous or intermittent pressurized harder systems Replaces a standard inlet section or mounts in line with a remote manifold kit Refer to bulletin L10104 for additional details Refer to bulletin SEeORD ER EER L10105 for modular zero leak PUMP AND RESERVOIR MASTER DIVIDER Shunt Inlet Section A three function valve either electric or pneumatic allows lubricant to enter divider valve bypa
4. listing of available performance indicators e Automatic Relief to Atmosphere Indicator O Ring Seal e Manual Reset Indicator with Memory O Ring Seal System spring loaded piston unseats when blockage occurs blockage triggers a spring loaded piston to display an venting lubricant to atmosphere each time piston cycles indicator Since there is no relief pressure backs up in This allows system to lubricate unaffected points When the system and the system stops allowing a controller to the blockage is cleared the indicator resets automatically alarm After correcting the problem the indicator pin is reset manually Description PartNo Old PartNo Description PartNo Old PartNo O Ring 1000 psi 69 bar 563172 i 61 bar O Ring 1500 psi 103 bar O Ring 1000 psi 69 bar Automatic Relief to Atmosphere Indicator Manual Reset Indicator with Memory Page 5 MSP Modular Divider Valves Designed with over 100 years of experience in centralized lubrication e Engineering certified to ISO 9001 Standards e Modular design for maximum flexibility e install and maintain without disturbing lube lines Quality Design 18 851 LUBE INLET TOP VIEW 3 000 922 TYP 6 2 23 419 1 750 rr 44 45 15 875 484 12 294 LUBE OUTLET WS OUTLET IS PLUGGED ON ONE SIDE WHEN CAPACITY SECTION IS SINGLED SIDE VIEW 484 12 294 INDICATOR PORT FRO
5. 00 025 15T 015 0 015 0 246 562722 106 100 195 15S 015 0 030 0 492 562713 106 100 035 20T 020 0 020 0 328 562723 106 100 205 562739 106 100 935 20S 020 0 040 0 656 562714 106 100 045 562729 106 100 735 25T 025 0 025 0 410 562724 106 100 215 562740 106 100 945 25S 025 0 050 0 820 562715 106 100 055 562730 106 100 745 30T 030 0 030 0 492 562725 106 100 225 562741 106 100 955 30S 030 0 060 0 983 562716 106 100 065 562731 106 100 755 35T 035 0 035 0 574 562726 106 100 235 562742 106 100 965 35S 035 0 070 1 148 562717 106 100 075 562732 106 100 765 40T 040 0 040 0 656 562727 106 100 245 562743 106 100 975 40S 040 0 080 1 311 562718 106 100 085 562733 106 100 775 Item Description Part No Old Part No 2 Subplate 1 8 27 NPSF 563425 527 000 311 7 16 20 SAE 563451 527 003 550 1 8 28 BSPP ISO 1179 563447 527 003 140 3 Inlet 1 4 18 NPSF 560919 527 001 800 7 16 20 SAE 560943 527 003 540 1 4 19 BSPP ISO 1179 560936 527 003 130 Inlet w Bleed 1 4 18 NPSF 563420 527 000 321 7 16 20 SAE 563422 527 000 325 4 End Section 563424 527 001 900 t End SPP 563279 510 770 332 5 Crossport Plate Right 563469 527 005 320 Left 563470 527 005 330 Both 563471 527 005 340 6 Singling Plate 563472 527 005 350 7 Bypass Block 562660 106 000 010
6. 27 004 790 N C 1 4 18 NPSF 563453 527 003 670 N C 9 16 18 SAE 563463 527 004 800 Replacement Coil 557214 492 120 128 Shunt Shut Off 24 VDC 3 Pin Brad Harrison Connector N O 1 4 18 NPSF 563454 527 003 680 N O 9 16 18 SAE 563482 527 005 780 N O 1 4 BSPP ISO 1179 563493 527 007 090 N C 1 4 18 NPSF 563455 527 003 690 N C 9 16 18 SAE 563483 527 005 785 N C 1 4 BSPP ISO 1179 563494 527 007 100 Replacement Solenoid 557215 492 120 130 Shunt Shut Off Pneumatic Operator 563456 527 003 730 Remote Manifold kit Zero Leak and Shunt Shut Off 1 4 18 NPSF 963461 527 004 360 9 16 18 SAE 527 005 400 Page 8 MSP Modular Divider Valves L10102 NOTE Part numbers shown on previous page are for standard plated steel with Buna N Seals Consult Graco for Viton Seals or stainless steel components Valve sections with cycle pin are standard Right Hand can be made Left Hand Consult factory Consult factory for components requiring thread connection series other than those listed t End Section SPP is supplied with plugged 1 8 27 NPS manual lube fitting port Order 412 700 490 manual lube fitting separate MSP Divider Valve Part List Schematic Modular design for full flexibility e One valve assembly serves up to 16 points e O Ring sealing throughout prevents leakage e Built in check valves prevent lube re entry and help keep lines full b BAO Page 9 MS
7. A In Rush 0 14 A Holding 24 VDC 28 W Page 7 Shunt Inlet Option LUBE BYPASS PORT 1 235 31 37 BRAD HARRISON 7 8 16 UNC THR D FOR 3 PIN CONNECTION CAN BE ROTATED TO DESIRED CONNECTION POSTION LUBE INLET 1 750 N 44 45 og N T 79 38 Shunt Shut Off Electrical Specifications 115 VAC 1 6 A In Rush 0 54 A Holding 24 VDC 28 W L10102 Solenoid mounted on right side n o to divider closed to bypass Solenoid mounted on left side n c to divider open to bypass MSP Modular Divider Valves You can easily configure the system to the need e Custom performance from stock modules e Choice of Single or Twin outlets Specifying Guide MSP Divider Valve Component Identification and Ordering Information Zinc plated carbon steel Description w Cycle Pin RH T Twin Displacement Buna N Seal Buna N Seal Item S Single in cm Part no Old PartNo PartNo Old Part No 1 Valve Sections 5T 005 0 005 0 082 562720 106 100 175 5S 005 0 010 0 164 562711 106 100 015 10T 010 0 010 0 164 562721 106 100 185 10S 010 0 020 0 328 562712 106 1
8. MS 40 SCR 5 section MSP Divider Valve Assembly standard seals SAE ports and ee we OL PLUGGED performance indicators in each working outlet Consisting of 1 030 Twin Valve with Cycle Pin Right Side 1 040 Single Valve Crossport Right Side 1 040 Single Valve Right Hand Outlet LUBRIQUIP MS 40S PLUGGED OPEN LUBRIQUIP MS 20 T OPEN O O OPEN LUBRIQUIP BY PASS 1 020 Twin Valve PLUGGED PLUGGED 1 Bypass Block Ordering Code MSP SAE MS P 5 30B 40SCR 40S 20T BP Page 10 MSP Modular Divider Valves L10102 Graco has applied automatic lubrication technology to a world of needs including yours Automated systems improve safety Maintenance personnel do not have to lubricate dangerous machinery Operators have less exposure to oil and lubricants on equipment and floor Graco systems require minimum attention Filling the reservoir and periodic inspections are the only routine maintenance required Graco s precise lubricant delivery eliminate lubricant waste product contamination and heat buildup from excessive viscous shear Lube delivery to machines in motion is ofter superior to static lubrication Oil and grease are forced into the load area to coat wear points Surges vibrations and other erratic operations are reduced with automatic lube systems This minimizes risk of damage to equipment products and personnel All Graco systems a
9. NT VIEW 4 MTG HOLES e 3 250 CB BOTH 3 000 SINGLING re fi a H E R wil J 7 VE iE l l Qty of CR Right Right CL Left 3 3 578 90 881 4 500 114 30 3 4 5 422 137 718 _ 6s ed signa None 6 344 161 138 7 7 266 184 556 8 8 188 207 975 281 7 137 DIA L10102 0 Ring Seals Standard 70 Durometer Buna N _ Optional 70 Durometer Viton Max Cycle Rate w Cycle Pin 60 CPM w out Cycle Pin or w Prox 200 CPM Cycle Sw Temperature max Buna N Seals 200 F 93 C Tee oa Viton Seals 350 F 177 C Zero Leak Inlet Pressure max 1500 psi 104 bar 140 F 60 C up to 5000 SUS Ambient Temperature max Lubricant oil only Requires 25 micron min filtra tion Electrical Characteristics Shunt Shut Off Inlet Pressure max See page 7 3000 psi 207 bar Intermittent supply pressure only 140 F 60 C Oil and Fluid Grease Ambient Temperature max Lubricant Filter oil through 25 micron filter and grease through a 100 mesh strainer Electrical Characteristics See page 7 DIVIDER VALVE ASSEMBLY aseton feee aseton fse Beton era 0 Ring sealed components kg 7 3 0 10 2 4 6 5 6 5 9 Page 6 MSP Modular Divider Valves Zero Leak Inlet Shut Off Valve MTG HOLE FOR 1 4 SOC HD SCREW PLACES 7 8 16 UNC THR D FOR BRAD HARRISON 3 PINCONNECTOR Zero Leak Electrical Specifications 115 VAC 0 22
10. P Modular Divider Valves How to Order Ordering Information xxx SERIES OF FEEDER XXX MSP STANDARD INDUSTRIAL TO 3500 PSI MSV SYNTHETIC INDUSTRIAL TO 3500 PSI VITON SEALS INLET OUTLET PORT TYPES SAE STRAIGHT THREAD O Ring SEAL NPT NPSF PIPE THREAD BPS BRITISH PARALLEL PIPE O Ring SEAL LSO 1179 MET METRIC THREAD O Ring ISO 6149 INLET SECTION OPTIONS MS MS DIVIDER INLET MH MS DIVIDER INLET W BLEED SCREWS SH MS DIVIDER W SHUNT SHUT OFF 115 VAC SD MS DIVIDER W SHUNT SHUT OFF 24 VDC ZL ZERO LEAK SHUT OF 115 VAC ZF ZERO LEAK SHUT OFF 24 VDC DIVIDER VALVE ACCESSORY OPTIONS P ASSEMBLY OF PERFORMANCE INDICATORS IN ALL WORKING OUTLETS B ASSEMBLY OF PERFORMANCE INDICATORS AND CHECK VALVES IN ALL WORKING OUTLETS C EXTERNAL CHECK VALVES IN ALL WORKING OUTLETS E SPP END SECTION W PLUG IN 1 8 27 NPSF PORT FOR MANUAL LUBE FITTING 563279 510 770 332 NUMBER OF SECTIONS 3 THREE 6 SIX 4 FOUR 7 SEVEN 5 FIVE 8 EIGHT VALVE CAPACITY MS VALVE BLOCK BP BYPASS 05 005 cu in 10 010 cu in 15 015 cu in 20 020 cu in 25 025 Cu in 30 030 Cu in 35 035 Cu in 40 040 cu in 082 cm 164 cm 246 cm 328 cm 410 cm 492 cm 574 cm 656 cm re ee ee ee S TYPE OF VALVE BLOCK TWIN VALVE SINGLE VALVE RH OUTLET SINGLE VALVE LH OUTLET TWIN VALE W CYCLE PIN RIGHT
11. Trabon MSP Modular Divider Valves Your key to maximum design flexibility with series progressive reliability PROVEN QUALITY LEADING TECHNOLOGY MSP Modular Divider Valves Match lubricant flow to the exact needs of each point e Precise monitoring positive feedback e Simple to install and operate e Modular design for total flexibility The flexible modular MSP Divider Valve e For grease or oil systems up to 3 500 psi 241 bar e Lubricate up to 16 points per valve assembly e Choice of SAE NPSF or BSPP inlet outlet connections O Ring sealing prevents leaks reduces maintenance e Individual valve outputs vary by a maximum ratio of 16 1 e Built in check valves prevent lube re entry and help keep lines full e Stackable design simplifies installation adds flexibility e Available in carbon steel with corrosion resistant plating Contact Graco s factory regarding 316 stainless steel for corrosive applications L10102 Each assembly includes 1 valve sections with working pistons 3 minimum 2 subplates with outlet ports 3 inlet section and 4 end sections Twin piston sections are ported to create separate outputs for two lube points Single sections combine the output from both ends of the piston and send it to a single lube point Field installable crossport or singling plates 5 may be used to increase the flow to a single point or accommodate an odd number of lube points A bypass section
12. re engineered for the machinery and Graco s automated systems deliver lubricant to vital lubricant being used We can even supply the lubricant mechanisms prolonging equipment life and reducing downtime matched to the system you need Page 11 Your solution is at hand Our years of engineering innovative lubrication technology plus our worldwide network of more than 100 distributors means that the components you need are probably in stock right now This inventory of proven components allows distributors and factory engineers to design a truly customized system using economical on the shelf parts New or upgrade Graco has the applied technology Whether you are considering new equipment or upgrading an existing system count on Graco for the applied lubrication technology to meet your need with a minimum of hassle and investment Call on our unparalleled customer support for fast efficient design installation maintenance and troubleshooting assistance or to get the name of your nearest full line factory trained distributor Front View m0 010 76 2 625 moe lt 15 875 y 484 12 294 l O a 12 294 D 281 7 137 DIA 4 MTG HOLES INDICATOR PORT Side View 2 188 55 563 125 a Top View 781 19 837 922 ave E 7 LUBE INLET 23 419 a OUTLET OUTLET IS PLUGGED 2 a j ON ONE SIDE WHEN CAPACITY SECTION RESIN C B
13. sses it to another divider valve or diverts it back to tank Replace standard inlet or mount in line with remote manifold kit LUBRICANT oo RESERVOIR TO LARGE BEARING CONTROLLER TT E m a a SE TC a EE ore MSP 3 MSP 4 MSP 4 TO BEARINGS Page 3 MSP Modular Divider Valves A wide variety of safeguards monitor and verify lube cycles e Track valve piston action e Easily interfaced to system controller Cycle Indicators These mechanical and electrical units sense the divider valve piston s action for accurate control and monitoring of lube cycles e Cycle Indicator Pin Valve sections are available with a factory installed indicator pin which moves in and out as lubricant passes through the valve e Universal Cycle Counter Six digit counter displays each complete cycle of the divider valve Requires divider valve section with indicator pin described above Part number 563444 527 002 410 led e Field sensitive Proximity Switch A ceramic magnet switch for grease or oil systems up to 200 cpm at pressure up to 3 500 psi 241 bar accurately signals piston cycles and is ideal for high cycle applications Part numbers 3 pin with O Ring 557741 527 003 251 5 pin with O Ring 557746 527 004 111 L10102 Magnetic Visual Indicator Six steel balls in a clear sleeve follow a magnet which moves with the cycling piston providing a clear visual indication of lube c
14. ycles Part number with O Ring 563251 509 932 522 Cycle Indicator Switch SPDT Used in conjunction with the cycle indicator pin at cycle rates not exceeding 60 cpm it provides an electrical signal to the system controller which counts cycles to monitor and verify completion of the lube cycle Part number 563272 510 599 000 A moisture resistant switch 563273 510 599 200 is also available if bua LED Field sensitive Proximity Switch This 24 VDC device magnetically senses the movement of the piston triggering the switch and illuminating the LED Part numbers 3 pin with O Ring 563478 527 005 690 5 pin with O Ring 563477 527 005 670 Explosion proof with O Ring 563485 527 006 060 Connecting Cables Brad Harrison mating cables with either 3 or 5 pin connectors are available in 12 ft 3 65 m lengths for the F S proximity switches and other devices Refer to bulletin 15600 for complete listing of proximity cycle switches Page 4 MSP Modular Divider Valves L10102 Choice of indicators offer automatic system protection and fault location e Immediate response to blockages e Manual or automatic reset e Continues to serve unaffected points Performance Indicators These vital safeguards react to excess lube pressure when points or lines become blocked Installed in indicator ports on the working piston sections they quickly identify the affected lines Refer to bulletin L15401 for complete