Home
        Genesis Advanced Technologies 2006 User's Manual
         Contents
1.  that  the ADD WATER light is off    e Check that the FAULT light is off     15    2  The ADD WATER light is on and there is sufficient  water in the bath     e With the unit unplugged and raised out of the water  check  that there is no obstruction around the float switch in the  shroud unit  The float should move freely up and down the  stem approximately half inch     3  The FAULT light is on     e Check the water temperature  If the water temperature is  above 58   C  the FAULT light will light and the unit will  not be operable    e If this temperature is reached  it may indicate a unit  malfunction    Contact GenesisBPS  LLC for further assistance     4  Unit does not heat  HEATING light is on but actual  water temperature is not increasing     e Remove rear cover and check the heating element for  continuity  Replace if necessary  This maintenance should  only be performed by a trained technician or GenesisBPS   LLC  Contact it or your Biomedical Department     5  Unit does not rock    e Check that the ADD WATER or FAULT lights are not  illuminated     6  Bath moves to side when rocking or the rocking motion is  not smooth     e Ensure that the bath is positioned on the white roller    e The unit must be operated on a smooth and level surface   Check the level of the work surface and make adjustments  if necessary     16    7  Pump does not circulate the water     e Debris may be in the pump impeller housing  Raise the  shroud unit and lock in the up position  Inspect 
2. 601 U S A    Tel  201 708 1400  866 712 5663   Fax  201 704 1104    www genesisbps com       RETURN INFORMATION      Same as above     1  Obtain a Return Goods Authorization number    2  Ensure all water is removed from the unit  including  inside the pump   This can be done by lowering the  control panel and tilting the unit forward               Towel dry the unit  especially around the pump         heater  before packing    4  Place water bath over the control panel and pack   GENESIS 2002 2006    securely in a box with clean   packing materials  no use polystyrene peanuts or chips as   packaging material     Check with GenesisBPS  LLC to determine   if water bath should be returned   usually only the   control panel is required     U      Please provide a brief description of difficulty experienced  or reason for return along with the following information      20    Hospital Account Name  Department and shipping address  Name and telephone number of contact  Date GENESIS 2002 2006    was purchased  Serial    RGA    Return Goods Authorization       6  Mark outside of box clearly  with your return address  and  send to GenesisBPS  LLC   as above     21    GENESIS 2002     GENESIS 2006     PLASMA THAWING WATER BATH SYSTEM    WARRANTY    The GENESIS 2002 2006     Plasma Thawing Water  Bath System is warranted against defects in materials  and workmanship for a period of one year from the  date of purchase  The warranty applies only to  products that have not been tampered wi
3. E A THAWED BAG    Press the ROCK key to stop the rocking motion       Remove the thawed bag  and any weights used  from the    Plasma Bag Holder  Discard plasma thawing overwrap bag  after each use  as they are designed for single use only       If there is another bag being thawed  press the ROCK key to    resume the rocking motion for the remaining bag     TO MAINTAIN THE DEVICE IN THE READY TO   THAW STATUS    Always keep the HEAT indicator illuminated     Always keep the SET TEMP to the desired setting   37   C or  other desired temperature   If a desired temperature of 50    C or greater is needed  limit the time the unit is in the ready  to use state  At higher temperatures  greater evaporation  occurs     Always keep the ROCK indicator off  not illuminated  when  not thawing plasma or other products     5       CLEAN THE BATH OR TO ADD WATER    SAFETY   NEVER ADD WATER OR MOVE  THE BATH IF THE POWER SWITCH  ON  THE LEFT SIDE PANEL  IS TURNED ON     RECOMMENDATION  FOR MAXIMUM  SAFETY  UNPLUG THE UNITS POWER  CORD FROM THE ELECTRICAL OUTLET        5 1 TURN THE POWER SWITCH  ON THE LEFT SIDE  PANEL  TO OFF POSITION TO TURN THE UNIT  POWER OFF     BEFORE REMOVING THE BATH FILLED WITH  WATER  UNPLUG THE UNIT FROM THE  ELECTRICAL OUTLET     5 2 Depending on usage  the water should be changed daily but  not less than once per week     5 3 Remove the Plasma Bag Holder     5 4 Tilt the unit to the up position by lifting the handle in front of  the control panel  With unit in u
4. MERIC KEYS  0   9      These keys are used to enter a  new value when the SET TEMP key or START CHANGE  key is pressed first     START CHANGE     This key has dual function  When  this key is pressed  the timer display starts countdown  from the default or preset timing  14 minutes for the  GENESIS 2002    and 18 minutes for GENESIS 2006       If a numeric key entry is made within 5 seconds  a new  time is set and displayed  and counts down     14    INDICATORS    HEATING         This red indicator is lit when the heating  element is actually drawing current from the circuit and  heating the water  When it reaches set temperature  the  heating indicator light shuts off     FAULT              If the water temperature exceeds 58   C   an alarm will sound and the red fault light will be  illuminated  This may indicate a unit malfunction     ADD WATER      This red indicator will light if there is  insufficient water in the bath  The unit will not operate   Add water to correct this condition  This indicator will  light also when the shroud unit is lifted in up position     7  TROUBLESHOOTING GUIDE  PROBLEM and ACTION    1  The indicator lights and displays do not come on when  the POWER key is pressed     e Check the POWER SWITCH on the left hand side    e Check the outlet for 110 120 VAC 60 Hz    e Check the fuse in the unit  Replace the fuse if necessary    e Ensure that the POWER key is pressed for at least one  second    e Check that there is sufficient water in the bath and
5. R  PIN  ensure the pin head is located in the slot of the bath   Ensure that the center of bath is positioned onto the white  roller on the base plate  Hold the handle firmly on the front of  the control panel  Release the clamp knob by tuming it  counterclockwise  Lower the unit slowly into the water     II    6  CONTROL PANEL AND INDICATORS          66G       OOOO C     TIMER MINUTES                               FAULT       GENESIS 2002            GENESIS 2002    CONTROL PANEL                get enw       IES J      s     UL    NESI  JO       GENESIS 2006    CONTROL PANEL                   CONTROL KEYS    POWER             This key turns the unit on and off when  the POWER SWITCH on the left panel is turned ON   The POWER SWITCH on the left panel is a master  on off switch to remove electrical power completely  from all circuits in the unit     SET                With this key switch you can adjust water  temperature within the range of ambient to   56   C   Numeric keys must be pressed within 5 seconds of each  other  otherwise display returns to the original figure     HEAT                This key turns the heater and water pump  on and off  An indicator to its right indicates its status   Even if this key is turned on  the HEATING indicator  light shuts off when water temperature reaches set  temperature     ROCK                This key makes the tub rock  An indicator  to its right indicates its status  Pressing this key at any  time will stop the rocking motion     NU
6. USER   S MANUAL    GENESIS 2002    GENESIS 2006      PLASMA THAWING WATER BATH SYSTEM    GENESIS ces    GenesisBPS  LLC   65 Commerce Way   Hackensack  NJ 07601 U S A    Tel  201 708 1400  866 712 5663   Fax  201 704 1104    www genesisbps com    0609    CLAMP KNOB  CONTROL PANEL  ROCKER PIN      i BAG HOLDER                    WATER BATH    POWER SWITCH  POWER CORD  FUSE HOLDER    THERMOMETER    BAG HOLDER       GENESIS 2006 SHOWN    To assure proper record keeping  please retain this information  for future use     DATE PURCHASED  SERIAL    DISTRIBUTOR NAME  PHONE NUMBER  CITY  STATE                   The GENESIS THAWING SYSTEMS incorporate water bath  technology with the latest engineering to enable the machine to  provide plasma thawing in a minimum of time  The unique   water resistant electronic key pad permits the operator to easily  monitor and control the thawing activity     The compact design of the GENESIS 2002 2006    saves  precious bench top space  It is easy to operate  keep clean and  maintain  The GENESIS 2002 2006    sets up in minutes and  is ready to use  The GENESIS 2002 2006    comes with 1000  plasma thawing bags  thawing bag dispenser  bag holder s    LABath CLEAN     reference thermometer  and two special  plasma thawing bag weights  Optional accessories are also  available     We are certain that you will be pleased with your new  GENESIS 2002 2006    plasma thawing water bath system  If  you have any questions  please call      GenesisBPS  LLC    a
7. ating   e Simple to operate   easy to read LED display   e Light weight   easy to carry   e Audio completion signal   e Complies with AABB standards for plasma thawing  e One year limited warranty    UNIQUE SAFEGUARDS    e Float switch prevents operation without water   e Water resistant membrane control panel   e Error code display   e Separate electronic circuit prevents overheating of water  e Alarm sounds for all fault conditions    18    10  SPECIFICATIONS    s    21 6    L x 8 3    Wide 26 6    L x 9 6    Wide  External Dimension f    x 13 2    High x 13 2    High    13 0    L x 7 0    Wide 18 0    L x 8 0    Wide  x 7 5    Deep x 7 5    Deep    Interior Bath Dimension  Bath Volume 2 5 US gallons 3 7 US gallons    Controlled Temp Range   Ambient to 56    Ambient to 56   C      C      110 120 220 240VAC   110 120 220 240VAC  Voltage Requirements ae  ex   50 60 Hz    50 60 Hz     Current Rating 7 0 Amps Maximum   11 5 Amps Maximum  Shipping Weight 20 Ibs 23 Ibs        This time may vary slightly depending on bag content volume   overwrap wrap material  storage temperature and air trapped          This machine is dependent on the frequency of AC mains   Operating frequency is marked on the rear panel     Note  Due to product improvements  the above specifications  are subject to change        19    11  ORDERING RETURN INFORMATION    ORDERING INFORMATION      To place an order for a part or an accessory  please call      GenesisBPS  LLC   65 Commerce Way   Hackensack  NJ 07
8. heated   This cycle continues  ensuring accurate water temperature     6    c  To change the default SET TEMP   You can adjust this  temperature within the range of ambient to   56   C  in one  degree increments  To adjust  press the SET TEMP key   then  press the numeric key pad to indicate the temperature desired   All keys must be pressed within 5 seconds of each other  The  display should now show the new SET TEMP     When the SET TEMP is same as the WATER TEMP  the  bath is ready to be used for thawing     d  Place the frozen product in slot marked 1 on the Plasma Bag  Holder     It is recommended that frozen plasma be placed into a plasma  overwrap thawing bag  This should prevent plasma from  getting into the bath  should the bag be cracked or damaged  and protect the device from damage  After placing frozen  plasma into the plasma thawing bag  eliminate all air from  bag  twist top of the bag and loop it through the Plasma Bag  Holder so it is secure    For additional overwrap thawing bags  call    GenesisBPS  LLC     It is important to remove the excess air  Place the  weight s  provided into the plasma bag s  to ensure that the  frozen plasma remains submerged in the water     e  Press the START CHANGE key for the selected bag location   The timer will start it   s count down while the unit is thawing  the plasma  Default timing is 14 minutes for the GENESIS  2002    and 18 minutes for the GENESIS 2006     After this  time has elapsed an alarm will sound  signaling 
9. p position  tighten the clamp  knob located on the top left hand side of the device  turn the  knob clockwise   DO NOT OVER TIGHTEN    The unit will now be held in the up position     It will be helpful at this point to have a cloth towel ready to  cleanup dripping water  Or  by waiting a few minutes  the  pump and heater area can drain into the water bath     5 5 GENESIS 2002     Carefully remove the water bath from the  device  The bath weighs approximately twenty  20  pounds  10    when filled with water  Do not drop the bath on a hard  surface     GENESIS 2006     Remove all  or part of the water  The bath  weighs approximately thirty  30  pounds when filled with  water  Carefully remove the water bath from the device        5 6 DO NOT USE BLEACH OR HARSH CLEANERS   Depending on mineral content of water used  the bath may  discolor  Proper cleansing should keep this to a minimum   Use LABath CLEAN    regularly to control bacteria  algae  and turbidity  To order additional LABath CLEAN     call  GenesisBPS  LLC at 866 712 5663     5 7 Fill the bath  The maximum water level should be  approximately two inches from the top of the water bath   This level will ensure that the water level will be at the  slotted line on the unit when the bath is repositioned     DON T OVERFILL THE BATH  Add 2 ml of LABath  CLEAN    each time water is changed    DON T USE BLEACH OR HARSH CLEANERS as this may  scratch and discolor bath     5 8 To replace bath  GENTLY place the bath onto the ROCKE
10. pump for  debris and remove with tweezers or similar instrument     8  HEATING light is flashing     e This is normal operation  At approximately one degree  below the set temperature  the microprocessor begins to  reduce the amount of heat generated and the HEATING  light begins to flash     9  Temperature display at WATER TEMP deviates from  thermometer reading     e Run the unit for more than 30 minutes    e Read thermometer temperature while the thermometer  remains in water  Remember the temperature reading    e Press the POWER key to turn the unit power off    e Press the SET TEMP key and the POWER key at the  same time  Power is turned on again but the WATER  TEMP display shows an arbitrary number    e Each time the  5  key is pressed  the number displayed  in WATER TEMP window increases by 0 1  Each time  the  0  key is pressed  it decreases by 0 1    Press either the  5  key or the  0  key until the WATER  TEMP shows same number as the thermometer reading   This adjustment should be done in one minute from  when you have read the thermometer    e Press the POWER key to turn power off    e Press the POWER key to turn power on again and  check calibration has been done correctly     17    SPECIAL FEATURES    e Thaws multiple plasma units simultaneously   e Thaws standard size plasma as well as cryoprecipitate  e Individual time setting for each bag location   e Forced water circulation with gentle rocking motion  e Compact size   saves valuable bench space   e Quick he
11. t  866 712 5663       10     11     12     CONTENTS    page  UNPACKING                          5  TO THAW BLOOD PRODUCTS                           5  TO REMOVE A THAWED                                 9  TO MAINTAIN THE DEVICE IN THE  READY TO THAW STATUS                                 9    TO CLEAN THE BATH OR TO ADD WATER   10    CONTROL PANEL AND INDICATORS              12  TROUBLESHOOTING GUIDE                             15  SPECIAL FEATURES    o 18  UNIQUE SAFEGUARDS                                      18  SPECIFICATIONS zin a es 19  ORDERING RETURN INFORMATION              20                       22    1  UNPACKING    1 1 The following is supplied with your GENESIS 2002 2006     unit   Control Unit  Water Bath  Thawing Bag Dispenser  Plasma Overwrap Thawing Bags  1000 Box   Plasma Bag Holder  LABath CLEAN     Reference Thermometer  Thawing Bag Weights  User s Manual    Optional Accessories    Additional Bag Weights    The above items may be purchased from      GenesisBPS  LLC  866 712 5663    2  TO THAW BLOOD PRODUCTS  2 1 Place the unit on a flat  sturdy surface     2 2 Fill bath with water up to the slotted line on the front of the  stainless steel shroud  This level will ensure proper thawing  operation  No bags should be in the bath and the unit should  be placed in the down position when filling the bath     Check water level daily  If the water level is too low  the  GENESIS 2002 2006    low water level sensing switch will  make the unit inoperable  when the 
12. th  used for  purposes other than those specified  or damaged  through misuse  accident  dropping  neglect or other  conditions beyond the control of the manufacturer  All  defective material parts will be repaired or replaced at  no charge during the warranty period  To have the  machine serviced  ship it  prepaid  to      GenesisBPS  LLC  65 COMMERCE WAY    HACKENSACK  NJ 07601       DO NOT SHIP MACHINE PRIOR TO CALLING  GenesisBPS  LLC  CUSTOMER SERVICE DEPARTMENT  at  866  712 5663 or  201  708 1400     No merchandise can be returned without prior authorization     22    
13. that the  frozen product should now be thawed     Depending on volume of plasma  the thickness of the plasma  thawing bag and storage temperature of product to be thawed     7    thawing time may vary  The amount of air left in the plasma  thawing bag during thawing will also affect thawing time   The laboratory personnel can set the desired thawing time for  each unit to be thawed  They do not have to all be set for the  same thaw time     f  To change the default TIMER    Press the START CHANGE key for the selected bag location   then press the numeric key pad for the desired minutes  All  keys must be pressed within 5 seconds of each other  Minutes  must be between   and 99     g  To start rocking motion of the bath  press the ROCK key     Rock indicator will light  Pressing the ROCK key at any time  will stop the rocking motion     NOTE   If the water spills over the top of the bath when    rocking motion begins  stop the bath from rocking and  remove a small amount of water        h  To thaw an additional bag  place it in slot 2  3  etc  Adjust  the timer as required  follow instructions in Section 2 5 f  above     The product should be thawed when an audible signal is  heard and the respective BAG TIMER is at zero  Remove the  product from that slot location  check the bag contents to  ensure that it is completely thawed  If additional thawing is  required  return the bag to the holder and set timer for the  desired thaw time     3          4 1    4 2    4 3    TO REMOV
14. unit is plugged into the  power supply   An alarm will sound and the ADD WATER    5    indicator will light  To correct this situation  fill bath with  water as explained above     Add 2 ml of LABath CLEAN    each time the water is  changed to control bacterial and algae growth  The bath  cleaning agent also helps to prevent the formation of turbidity  and odor     2 3 Plug the device into a 115 volt AC outlet  For GENESIS  2002     a dedicated 10 Ampere outlet is needed  For the  GENESIS 2006     a dedicated 15 Ampere outlet is needed   The outlet must be properly grounded     IMPORTANT   DO NOT use sharp instruments  pen     pencil  etc   on the key pad area   it will cause damage  to the instrument        2 4 Turn on the POWER SWITCH on the left panel     2 5 Start the unit by pressing the POWER key located on the  control panel     a  The default SET TEMP is 37   C  When switching on the unit  this temperature will be displayed in the SET TEMP window   as the desired temperature  along with the actual WATER  TEMP of the bath  The bag timers will display zeros     b  If the water temperature is less than the set temperature   37   C  then heating of the water will begin automatically    the HEAT indicator will light  In addition  the HEATING  indicator will light  indicating the heater is drawing power   When the bath water reaches the set temperature  HEATING  indicator will go off  When the bath water cools  HEATING  indicator will go on again  indicating water is being 
    