Home
GE W1LR Installation Guide
Contents
1. any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate Customer wiring enters either through the center hole in the back plate orthroughthe conduit entrance knock outs onthe sides of the front housing In either case an easy access wiring area see figure 2 is provided for electrical connections Route incoming supply conductors through clips provided and maintain half inch minimum spacing from ballast and reflector NOTE Connect ground lead to ground gnd screwon the back plate Donotremove insulated connectors from wires not needed for required voltage connection IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire To complete installation refer to MOUNTING LAMP INSTALLATION AY CAUTION Risk of burn e Allow lamp fixture to cool before handling A WARNING Risk of burn e Donottouch operating luminaire Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly balla
2. GE Lighting Solutions GEH 3932C INSTRUCTIONS Wallighter 175 and Wallighter 250 Cutoff Luminaires READ THOROUGHLY BEFORE INSTALLING WILR W1SR W1LG W1SG W25C cutoff optics A WARNING Risk of electric shock e Turn power off before servicing seeinstructions A WARNING Risk of fire e Use supply wire specified on nameplate GENERAL This luminaire is designed for outdoor lighting applications and should not be used in areas of limited ventilation or in high ambient temperature enclosures For optimum performance it should be installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm INSTALLATION The refractor must be removed to access two bolts on each side of the reflector which secures front housing to back plate Removal of the front housing allows access for mounting and wiring NOTE For units marked W25C having socket mounted in front housing plug wire assembly located in center top of back plate must be unplugged while removing front housing A gasket is provided with the unit to be used when mounting over an outlet box and should be installed between rear of back plate and the mounting surface If additional sealing is desired caulk back of housing with generic non hardening sealant not provided across th
3. e top and down both sides A MOUNTING CAUTION Unit will fall if not installed properly e Follow installation instructions Outlet Box Mounting The luminaire can be mounted to a suitable surface mounted outlet box 3 or 4 octagon or 2 x4 rectangular The back plate may be attached to the outlet box with two 10 24 screws not provided approximately long An alternate method of mounting the back plate over a surface mounted outlet boxis to position back plate over box and mount with two 3 8 bolts not provided through the knock out holes provided in the back plate see figure 2 Wire the unit see Wiring Reattach the front housing reflector over the back plate For W25C having socket mounted in front housing plug wire assembly must be re connected as front housing is installed 686 in 17mm DIA KNOCKOUT FOR PE KIT ASSEMBLY Figure 1 12 875 in 327mm 4 438 in el 367mm 356 in 9mm DIA KNOCKOUT 4PLACES 188in 5mm DIA KNOCKOUT FOR USE WITH 4 000 in 102mm OCTAGON BOX 4 PLACES Fig ure2 1 375 in 35mm MAX 625 in 16mm MIN 6 344 in 161mm 875 in 22mm DIA 4 000 in 102mm 2 PLACES 8 000 in 203mm 188 in 5mm DIA KNOCKOUT FOR USE WITH 3 250 in 83mm OCTAGON BOX 4 PLACES 188 in 5mm DIA KNOCKOUT FOR USE WITH GEM BOX 2 PLACES These instructions do not purport to cover all details or variations i
4. n equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions Through Feed Conduit Note Some units may not allow this mounting or may require special high temperature cable See labels on back plate for instruction Knock out holes are provided to permit mounting of the back plate on vertical surfaces with two 3 8 bolts not provided The inch conduitisthen positioned inthe cradles on each side of back plate and secured to back plate with clips and screws provided see figure 2 The conduit may also be secured to the wall on either side of the fixture with conduit straps not provided Wire the unit see Wiring Knock out the sections on each side of the front housing using pliers twisting inwardly Re attach the front housing reflector over the back plate For W25C having socket mounted in front housing plug wire assembly must be re connected as front housing is installed Install lamp see LAMP INSTALLATION and re install refractor or cut off optical assembly NOTE Do not overcompress the gasket on acrylic lens units as this may cause the lens to crack around the screw holes B WIRING Make all electrical connectionsin accordance with the National Electrical Code and
5. st type burning position etc Lamp Tightness Mogul BaseLamp Thelampshouldbesecurely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firm tightening sufficient to fully depress and load the center contact of the socket Lamp Tightness Medium Base Lamp The lamp should be tightened to a light firmness sufficient to depress the center contact MAINTENANCE AND CLEANING It will occasionally be necessary to clean the outside of the refractor to maintain light levels Frequency of cleaning will depend on ambient dirt level and minimum light level which is acceptable to the user The refractor should be washed in a solution of warm water and any mild nonabrasive household detergent rinsed with clean water and wiped dry Should the optical assembly become dirty on the inside wipe the reflector and clean the refractor in the above manner The light output of a luminaire is dependent on the age of the lamp In applications where the light level is critical it may be desirable to replace lamps before they burn out The lamp manufacturer can provide data showing howthelamplight output decreases with use GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Ligh
6. ting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 M3 11 99
Download Pdf Manuals
Related Search
Related Contents
IST– Instituto Superior Técnico Tabique Real Const CALENDRIER PREVISIONNEL PROMOTION 2015 Operating Manual Rox.12 USX 1 式 3.使用目的:マウスなどの組織 VIZIO XVT553SV LCD TV Sitecom eSATA PCI Card Copyright © All rights reserved.
Failed to retrieve file