GE VBC Installation Guide
Contents
1. Figure 10 If so equipped the internal reflectors can be oriented to direct light in the intended direction by rotating them When used for parking garage applications the reflectors are aligned with direction of traffic see Figure 10 If re alignment is necessary grasp lower edge of the reflector on either side and rotate to the desired position MAINTENANCE CAUTION Risk of burn e Allow lamp fixture to cool before handling Cleaning Occasionally it will be necessary for the refractor to be cleaned to maintain appearance and light levels The frequency of cleaning will be dependent on the ambient dirt level and minimum light level required Refractor and housing should be washed with a solution of warm water and mild household detergent rinsed with clean water and wiped dry Should the interior optical assembly become dirty clean the reflector and interior of refractor as described above Replace gasket if damaged Lamp Replacement Light output of a luminaire is also dependent on the age of the lamp In applications where light level is critical it may be desirable to replace lamps before the burn out Consult lamp manufacturer s data for lamp replacement frequency and other safety issues Replace blackened lamps immediately GE Lighting Solutions 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other tr
2. conductors through wire clip D Figure 5 provided Re attach nomex shield 6 Reassemble luminaire C Flexible Pendant Mounting 1 Follow procedure for rigid pendant mounting B1 B 6 2 If adjustment is needed to balance luminaire and have conduit hang vertical loosen the four screws in the slotted holes slide the mounting hub until luminaire hangs straight re tighten screws Use widest bolt spacing possible to secure hub to cover Screws 6 Inches 152 mm Hub Gasket m NN Figure 6 D Luminaires with primary disconnects outlet box hanging hardware Figure 7 rigid pendant hardware Figure 8 and flexible pendant hanging hardware Figure 9 1 Remove cover plate s and attach hanging hardware to pendant conduit and tighten set screw ty a Elfctaig w r GENERAL PR Figure 7 Figure 8 Figure 9 2 Feed supply wire through conduit and into disconnect housing Make necessary wire connections 3 Slide the extrusion attached to the luminaire completely into the hanger extrusion Replace cover plate Cover plate is necessary to lock luminaire into place on the hardware cover electrical connections and if so equipped seal unit from water WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate IF SINGLE VOLTAGE All single voltage wattage ballas
3. GE Lighting Solutions A WARNING Risk of electric shock e Turn power off before servicing see instructions GENERAL This luminaire is designed for pendant or ceiling mounting applications and should be installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm The carton should contain a luminaire complete with mounting assembly and the lamp installed in the socket medium base version only INSTALLATION CAUTION Unit will fall if not installed properly e Follow installation instructions If unit is multi volt see Wiring Section below Luminaire Mountings A Ceiling Mounting 1 Attach mounting plate to electrical junction box and pull incoming power leads through oval hole in mounting plate 2 Suspend luminaire below j box and attach wireform by squeezing legs together slightly and inserting through rectangular j box mounting plate holes 3 With luminaire hanging below j box make electrical connections and place wires into j box Figure 1 4 Swing luminaire into place mate two mounting plates and slide together until plates lock into place Figure 2 5 Toremove fixture from j box luminaire must be opened by loosening three refractor ring screws then loosening reflector screws rotating and removing reflector The locking screw must be backed out approximate
4. ademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 Z6 10 03
5. ly one half inch Figure 3 Figure 1 i GEH 5787B INSTRUCTIONS J Versabeam Luminaire Locking Screw Se aes me Junction Box Mounting N Ae Plate Figure 2 Figure 3 B Rigid Pendant Mounting 1 Loosen three refractor ring screws and remove refractor and refractor ring from luminaire housing 2 Loosen reflector screws rotate and remove reflector Remove nomex wire shield Note Nomex shield may be discarded if 105 C or above wiring is used 3 Thread pendant conduit into top housing Figure 4 or mounting hub Figure 6 and tighten lock nut 4 Feed wires through pendant and extend approximately 6 inches of wire into housing and make necessary connections See Wiring section Connect supply ground lead to the luminaire green lead Locknut By User By 6 Inches 152mm Cover Figure 4 Pa _ Cover yr 10 _ Connectors yy _ Ballast lt Wire Clip Ground Lead Figure 5 ae These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions 5 Routeincoming supply
6. ts are pre wired such that user need only connect supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballastleadwith insulated terminal to desired voltage terminal as indicated on ballast terminal nameplate When changing voltage on re connectable units move only the lead with the insulated connector To access the ballast a Loosen three refractor ring screws and remove refractor and refractor ring from luminaire housing b Loosen reflector screws rotate and remove reflector c Consult wiring diagram inside luminaire for location of the tap for desired voltage LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp Lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket Lamp Tightness Medium Base Lamp Lamp should be tightened to a light firmness sufficient to depress the center contact of the socket Switched Quartz Units equipped for switched quartz operation will have the socket installed in the reflector Install quartz lamp ORIENTATION FOR OPTIONAL INTERNAL REFLECTORS Traffic Flow _ gt gt Lighting pattern Lighting pattern
Download Pdf Manuals
Related Search
Related Contents
Samsung RL370EGTS User Manual TWR-ADCDAC-LTC Manual RXA Husqvarna GTH250XP User's Manual MODE D`EMPLOI Montréal - Park(ing) Day Montréal Virage ambulatoire & Hôpital de demain Manuel du drone AP10 Eurofase 23048-027 Installation Guide Multibrackets 7350022732650 flat panel floorstand 取扱説明書 Copyright © All rights reserved.